METHODS
IN
TM
BIOTECHNOLOGY
䊐 19
Pesticide
Protocols
Edited by
José L. Martínez Vidal
Antonia Garrido Frenich
Pesticide Protocols
™
METHODS IN BIOTECHNOLOGY
John M. Walker, SERIES EDITOR
21. Food-Borne Pathogens, Methods and Protocols, edited by Catherine
Adley, 2006
20. Natural Products Isolation, Second Edition, edited by Satyajit D.
Sarker, Zahid Latif, and Alexander I. Gray, 2005
19. Pesticide Protocols, edited by José L. Martínez Vidal and Antonia
Garrido Frenich, 2006
18. Microbial Processes and Products, edited by Jose Luis Barredo, 2005
17. Microbial Enzymes and Biotransformations, edited by Jose Luis
Barredo, 2005
16. Environmental Microbiology: Methods and Protocols, edited by John
F. T. Spencer and Alicia L. Ragout de Spencer, 2004
15. Enzymes in Nonaqueous Solvents: Methods and Protocols, edited by
Evgeny N. Vulfson, Peter J. Halling, and Herbert L. Holland, 2001
14. Food Microbiology Protocols, edited by J. F. T. Spencer and Alicia
Leonor Ragout de Spencer, 2000
13. Supercritical Fluid Methods and Protocols, edited by John R.
Williams and Anthony A. Clifford, 2000
12. Environmental Monitoring of Bacteria, edited by Clive Edwards,1999
11. Aqueous Two-Phase Systems, edited by Rajni Hatti-Kaul, 2000
10. Carbohydrate Biotechnology Protocols, edited by Christopher Bucke,
1999
9. Downstream Processing Methods, edited by Mohamed A. Desai, 2000
8. Animal Cell Biotechnology, edited by Nigel Jenkins, 1999
7. Affinity Biosensors: Techniques and Protocols, edited by Kim R.
Rogers and Ashok Mulchandani, 1998
6. Enzyme and Microbial Biosensors: Techniques and Protocols, edited
by Ashok Mulchandani and Kim R. Rogers, 1998
5. Biopesticides: Use and Delivery, edited by Franklin R. Hall and Julius
J. Menn, 1999
4. Natural Products Isolation, edited by Richard J. P. Cannell, 1998
3. Recombinant Proteins from Plants: Production and Isolation of
Clinically Useful Compounds, edited by Charles Cunningham
and Andrew J. R. Porter, 1998
2. Bioremediation Protocols, edited by David Sheehan, 1997
1. Immobilization of Enzymes and Cells, edited by Gordon F.
Bickerstaff, 1997
™
METHODS I N BIOTECHNOLOGY
Pesticide Protocols
Edited by
José L. Martínez Vidal
Antonia Garrido Frenich
Department of Analytical Chemistry, Faculty of Sciences
University of Almería, Almería, Spain
© 2006 Humana Press Inc.
999 Riverview Drive, Suite 208
Totowa, New Jersey 07512
www.humanapress.com
All rights reserved. No part of this book may be reproduced, stored in a retrieval system, or transmitted in
any form or by any means, electronic, mechanical, photocopying, microfilming, recording, or otherwise
without written permission from the Publisher. Methods in BiotechnologyTM is a trademark of The Humana
Press Inc.
All papers, comments, opinions, conclusions, or recommendations are those of the author(s), and do not
necessarily reflect the views of the publisher.
This publication is printed on acid-free paper. ∞
ANSI Z39.48-1984 (American Standards Institute)
Permanence of Paper for Printed Library Materials.
Cover design by Patricia F. Cleary
Cover illustration provided by José L. Martínez Vidal and Antonia Garrido Frenich.
For additional copies, pricing for bulk purchases, and/or information about other Humana titles, contact
Humana at the above address or at any of the following numbers: Tel.: 973-256-1699; Fax: 973-256-8341;
E-mail: orders@humanapr.com; or visit our Website: www.humanapress.com
Photocopy Authorization Policy:
Authorization to photocopy items for internal or personal use, or the internal or personal use of specific
clients, is granted by Humana Press Inc., provided that the base fee of US $30.00 per copy is paid directly
to the Copyright Clearance Center at 222 Rosewood Drive, Danvers, MA 01923. For those organizations
that have been granted a photocopy license from the CCC, a separate system of payment has been arranged
and is acceptable to Humana Press Inc. The fee code for users of the Transactional Reporting Service is:
[1-58829-410-2/06 $30.00].
Printed in the United States of America. 10 9 8 7 6 5 4 3 2 1
eISBN 1-59259-929-X
Library of Congress Cataloging-in-Publication Data
Pesticide protocols / edited by José L. Martínez Vidal, Antonia Garrido Frenich.
p. cm. -- (Methods in biotechnology ; 19)
Includes bibliographical references and index.
ISBN 1-58829-410-2 (alk. paper) -- ISBN 1-59259-929-X (eISBN)
1. Pesticides--Analysis--Laboratory manuals. I. Vidal, José L. Martínez.
II. Frenich, Antonia Garrido. III. Series.
RA1270.P4P4685 2005
363.17'92--dc22
2005046201
Preface
Pesticides are a broad class of bioactive compounds used in crop protection, food
preservation, and human health. They differ from other chemical substances because
they are spread deliberately into the environment. Presently, about 1000 active
ingredients have been registered that can be grouped into more than 40 classes of
chemical families. Exposure to pesticides through the most important routes of uptake
(oral, dermal, and inhalation) depends on the physicochemical characteristics of the
pesticide and the nature of the contact, varying with the edge, lifestyle, and working
conditions. The level of pesticides in different environmental compartments—such as
water, agricultural foods, and products of animal origin—has became a relevant issue.
Moreover, analytical measurements of dermal exposure and exposure by inhalation
have become as important as analytical measurements of internal dose.
Unlike other contaminants, pesticides may affect both workers and the general
population as a result of the consumption of contaminated food and water, domestic
use, and proximity to agricultural settings. Information about actual human exposure
to pesticides has important uses, including informing risk assessments, helping predict
the potential consequences of exposures, and developing exposure criteria for
regulations and other public policy guidance.
Pesticide exposure can be measured through the biomonitoring of the parent
compounds and/or metabolites in such body fluids as urine, blood, serum, and saliva,
among others. Indoor exposure may take place through treated furniture, or such home
structures as fitted carpets or wood-treated walls. Regarding outdoor exposure, the
main sources are represented by spray drifts of pesticides from agricultural and
industrial areas and by the atmospheric dispersal of pesticides evaporated from treated
surfaces. Very little information is available on dermal and inhalation exposure to
pesticides. Contamination of food represents one of the most pervasive sources of
pesticide exposure for the general population.
Pesticide analysis has been affected by the recent detection of parent or metabolite
compounds, thus driving the demand for techniques that can measure lower and lower
levels of concentration. In recent years, criteria to support in a solid way the steps
corresponding to the identification, confirmation, and quantification of the analyte
have became more frequently used.
During the last decade, noticeable changes in multiresidue methods have taken
place. Chromatography remains the workhorse technique for pesticides. The
development of different types of injection techniques, columns, stationary phases,
and detectors has allowed for the improvement in the sensitivity and selectivity of the
analytical determinations. The availability in analytical laboratories of mass
spectrometry detectors coupled to gas chromatography, as well as to liquid
chromatography, has increased the degree of confidence in the identification of organic
compounds. Other techniques, such as capillary electrophoresis, are promising
v
vi
Preface
candidates for a relevant role in this area. The current use of powerful analytical tools
coupled with the application of quality control/quality assurance criteria has resulted
in an increase in the reliability of an analysis. However, special emphasis is needed on
the development of multiresidue methods for the analysis of as many pesticides as
possible in one analytical run.
Pesticide Protocols contains methods for the detection of specific compounds or
their metabolites useful in biological monitoring and in studies of exposure via food,
water, air, and skin. Liquid and gas chromatography coupled to mass spectrometry
detection, and other classic detectors, are the most widely used techniques, although
such others as capillary electrophoresis and immunochemical or radioimmunoassay
methods are also proposed. Chapters cover the varied array of analytical techniques
applied to the analysis of several families of pesticides. The extractions and cleanup
procedures have been focused in order to use more automated and miniaturized
methods, including solid-phase extraction, solid-phase micro-extraction, microwaveassisted extraction, or on-line tandem liquid chromatography (LC/LC) trace
enrichment, among others.
All methods have been written by scientists experienced in pesticide analysis in
different matrixes. Each chapter describes a specific method, giving the analytical
information in sufficient detail that a competent scientist can apply it without having
to consult additional sources. Our book will prove valuable as a general reference and
guide for students and postgraduates, as well for researchers and laboratories alike.
We would like to express our personal gratitude to all the authors for the quality of
their contributions. Thanks are also owed to Professor John Walker and to Humana
Press for allowing us to edit this volume.
José L. Martínez Vidal
Antonia Garrido Frenich
Contents
Preface .............................................................................................................. v
Contributors .....................................................................................................xi
PART I. ANALYTICAL METHODOLOGIES TO DETERMINE PESTICIDES
AND METABOLITES IN HUMAN FAT TISSUES AND BODY FLUIDS
1 Analysis of Endocrine Disruptor Pesticides in Adipose Tissue
Using Gas Chromatography–Tandem Mass Spectrometry:
Assessment of the Uncertainty of the Method
José L. Martínez Vidal, Antonia Garrido Frenich, Francisco J. Egea
González, and Francisco J. Arrebola Liébanas ....................................... 3
2 Determination of Pyrethroids in Blood Plasma and Pyrethroid/
Pyrethrin Metabolites in Urine by Gas Chromatography–Mass
Spectrometry and High-Resolution GC–MS
Gabriele Leng and Wolfgang Gries .............................................................. 17
3 A Multianalyte Method for the Quantification of Current-Use
Pesticides in Human Serum or Plasma Using Isotope Dilution
Gas Chromatography–High-Resolution Mass Spectrometry
Dana B. Barr, Roberto Bravo, John R. Barr, and Larry L. Needham ...... 35
4 Application of Solid-Phase Disk Extraction Combined
With Gas Chromatographic Techniques for Determination
of Organochlorine Pesticides in Human Body Fluids
Adrian Covaci ................................................................................................. 49
5 A Comprehensive Approach for Biological Monitoring of Pesticides
in Urine Using HPLC–MS/MS and GC–MS/MS
Dana B. Barr, Anders O. Olsson, Roberto Bravo, and Larry L. Needham ... 61
6 Urinary Ethylenethiourea as a Biomarker of Exposure
to Ethylenebisdithiocarbamates
Silvia Fustinoni, Laura Campo, Sarah Birindelli, and Claudio Colosio ...... 79
7 Analysis of 2,4-Dichlorophenoxyacetic Acid and 2-Methyl-4Chloro-Phenoxyacetic Acid in Human Urine
Cristina Aprea, Gianfranco Sciarra, Nanda Bozzi, and Liana Lunghini ..... 91
8 Determination of Herbicides in Human Urine by Liquid
Chromatography–Mass Spectrometry With Electrospray Ionization
Isabel C. S. F. Jardim, Joseane M. Pozzebon,
and Sonia C. N. Queiroz ........................................................................ 105
vii
viii
Contents
9 Analysis of Pentachlorophenol and Other Chlorinated Phenols
in Biological Samples by Gas Chromatography or Liquid
Chromatography–Mass Spectrometry
Ji Y. Zhang ................................................................................................... 111
10 Analysis of 2,4-Dichlorophenoxyacetic Acid in Body Fluids
of Exposed Subjects Using Radioimmunoassay
Dietmar Knopp ............................................................................................. 119
11 A High-Throughput Screening Immunochemical Protocol
for Biological Exposure Assessment of Chlorophenols
in Urine Samples
Mikaela Nichkova and M.-Pilar Marco ..................................................... 133
PART II. ASSESSMENT
OF INHALATORY AND
POTENTIAL DERMAL EXPOSURE
12 Assessment of Postapplication Exposure to Pesticides in Agriculture
Joop J. van Hemmen, Katinka E. van der Jagt, and Derk H. Brouwer ..... 149
13 Field Study Methods for the Determination
of Bystander Exposure to Pesticides
C. Richard Glass .......................................................................................... 165
14 Determination of Household Insecticides in Indoor Air by Gas
Chromatography–Mass Spectrometry
Edith Berger-Preiss and Lutz Elflein ......................................................... 179
15 Assessment of Dermal and Inhalatory Exposure of Agricultural
Workers to Malathion Using Gas Chromatography–Tandem
Mass Spectrometry
Francisco J. Egea González, Francisco J. Arrebola Liébanas,
and A. Marín ........................................................................................... 191
16 Pesticides in Human Fat and Serum Samples
vs Total Effective Xenoestrogen Burden
Patricia Araque, Ana M. Soto, M. Fátima Olea-Serrano,
Carlos Sonnenschein, and Nicolas Olea ............................................... 207
PART III. PESTICIDE ANALYSIS
IN
FOOD
17 Quality Criteria in Pesticide Analysis
Antonia Garrido Frenich, José L. Martínez Vidal,
Francisco J. Egea González, and Francisco J. Arrebola Liébanas ... 219
18 Immunoassay Methods for Measuring Atrazine
and 3,5,6-Trichloro-2-Pyridinol in Foods
Jeanette M. Van Emon and Jane C. Chuang ............................................ 231
19 Quick, Easy, Cheap, Effective, Rugged, and Safe Approach
for Determining Pesticide Residues
Steven J. Lehotay ......................................................................................... 239
Contents
ix
20 Determination of Organophosphorus Pesticide Residues in Vegetable
Oils by Single-Step Multicartridge Extraction and Cleanup
and by Gas Chromatography With Flame Photometric Detector
Alfonso Di Muccio, Anna M. Cicero, Antonella Ausili,
and Stefano Di Muccio ........................................................................... 263
21 Multiclass Pesticide Analysis in Vegetables Using Low-Pressure
Gas Chromatography Linked to Tandem Mass Spectrometry
Francisco J. Arrebola Liébanas, Francisco J. Egea González,
and Manuel J. González Rodríguez ....................................................... 273
22 Use of Matrix Solid-Phase Dispersion for Determining Pesticides
in Fish and Foods
Steven A. Barker .......................................................................................... 285
23 Analysis of Fungicides in Fruits and Vegetables by Capillary
Electrophoresis–Mass Spectrometry
Yolanda Picó ................................................................................................ 297
24 Application of Supercritical Fluid Extraction
for the Analysis of Organophosphorus Pesticide Residues
in Grain and Dried Foodstuffs
Kevin N. T. Norman and Sean H. W. Panton ........................................... 311
25 Application of Microwave-Assisted Extraction for the Analysis
of Dithiocarbamates in Food Matrices
Euphemia Papadopoulou-Mourkidou, Emmanuil Nikolaos Papadakis,
and Zisis Vryzas ....................................................................................... 319
26 Enantioselective Determination of α-Hexachlorocyclohexane
in Food Samples by GC–MS
Chia-Swee Hong and Shaogang Chu ........................................................ 331
PART IV. PESTICIDE ANALYSIS
IN
WATER
27 Automated Headspace Solid-Phase Microextraction and Gas
Chromatography–Mass Spectrometry for Screening
and Determination of Multiclass Pesticides in Water
Taizou Tsutsumi, Mitsushi Sakamoto, Hiroyuki Kataoka,
and Janusz Pawliszyn ............................................................................. 343
28 Analysis of Herbicides in Water by On-Line In-Tube
Solid-Phase Microextraction Coupled With Liquid
Chromatography–Mass Spectrometry
Hiroyuki Kataoka, Kurie Mitani, and Masahiko Takino ......................... 365
29 Coupled-Column Liquid Chromatography
for the Determination of Pesticide Residues
Elbert Hogendoorn and Ellen Dijkman ..................................................... 383
x
Contents
30 On-Line Admicelle-Based Solid-Phase Extraction–Liquid
Chromatography–Ionization Trap Mass Spectrometry
for the Analysis of Quaternary Ammonium Herbicides
in Drinking Water
Dolores Pérez-Bendito, Soledad Rubio, and Francisco Merino .............. 405
31 Molecular Imprinted Solid-Phase Extraction for Cleanup
of Chlorinated Phenoxyacids From Aqueous Samples
Claudio Baggiani and Cristina Giovannoli ............................................... 421
32 Automated Trace Analysis of Pesticides in Water
Euphemia Papadopoulou-Mourkidou, John Patsias,
and Anna Koukourikou .......................................................................... 435
33 Gas Chromatography–High-Resolution Mass Spectrometry-Based
Method for the Simultaneous Determination of Organotin
Compounds in Water
Michael G. Ikonomou and Marc P. Fernandez ........................................ 453
34 Determination of Triazine Herbicides and Degradation Products
in Water by Solid-Phase Extraction and Chromatographic
Techniques Coupled With Mass Spectrometry
Hassan Sabik and Roger Jeannot .............................................................. 467
35 An Optical Immunosensor for Pesticide Determination
in Natural Waters
Sara Rodríguez-Mozaz, Maria J. López de Alda, and Damia Barceló ....... 481
Index ............................................................................................................. 491
Contributors
CRISTINA APREA • Unità Funzionale di Igiene Industriale e Tossicologia Occupazionale
(Department of Industrial Hygiene and Occupational Toxicology) Laboratorio
di Sanità Pubblica, Azienda USL 7 (Public Health Laboratory, National Health
Service Local Unit 7), Siena, Italy
PATRICIA ARAQUE • Laboratory of Medical Investigations, Hospital Clínico, University
of Granada, Granada, Spain
FRANCISCO J. ARREBOLA LIÉBANAS • Department of Analytical Chemistry, Faculty
of Sciences, University of Almería, Almería, Spain
ANTONELLA AUSILI • Department of Environmental Quality Monitoring, Istituto
Centrale per La Ricerca Scientifica e Tecnologica Applicata al Mare (Institute
for Scientific and Applied Marine Research), Rome, Italy
CLAUDIO BAGGIANI • Dipartimento di Chimica Analitica, Università di Torino, Torino,
Italy
DAMIA BARCELÓ • Department of Environmental Chemistry, IIQAB-CSIC, Barcelona,
Spain
STEVEN A. BARKER • Analytical Systems Laboratories, School of Veterinary Medicine,
Louisiana State University, Baton Rouge, LA
DANA B. BARR • National Center for Environmental Health, Centers
for Disease Control and Prevention, Atlanta, GA
JOHN R. BARR • National Center for Environmental Health, Centers
for Disease Control and Prevention, Atlanta, GA
EDITH BERGER-PREISS • Fraunhofer Institute of Toxicology and Experimental Medicine,
Hannover, Germany
SARAH BIRINDELLI • International Centre for Pesticides and Health Risk Prevention,
Ospedale Universitario Luigi Sacco–Busto Garolfo, Milan, Italy
NANDA BOZZI • Unità Funzionale di Igiene Industriale e Tossicologia Occupazionale
(Department of Industrial Hygiene and Occupational Toxicology) Laboratorio
di Sanità Pubblica, Azienda USL 7 (Public Health Laboratory, National Health
Service Local Unit 7), Siena, Italy
ROBERTO BRAVO • National Center for Environmental Health, Centers
for Disease Control and Prevention, Atlanta, GA
DERK H. BROUWER • TNO Chemistry, Food and Chemical Risk Analysis, Zeist, The
Netherlands
LAURA CAMPO • Department of Occupational and Environmental Health, University
of Milan and Ospedale Policlinico, Mangiagallie Regina Elena, Milan, Italy
SHAOGANG CHU • Great Lakes Institute for Environmental Research, University
of Windsor, Windsor, Ontario, Canada
xi
xii
Contributors
JANE C. CHUANG • Battelle, Columbus, OH
ANNA M. CICERO • Department of Environmental Quality Monitoring, Istituto Centrale
per La Ricerca Scientifica e Tecnologica Applicata Al Mare (Institute for Scientific
and Applied Marine Research), Rome, Italy
CLAUDIO COLOSIO • International Centre for Pesticides and Health Risk Prevention,
Ospedale Universitario Luigi Sacco–Busto Garolfo, Milan, Italy
ADRIAN COVACI • Toxicological Center, University of Antwerp, Universiteits-Plein,
Wilrijk, Belgium
ALFONSO DI MUCCIO • Formerly at Laboratory of Applied Toxicology, Istituto Superiore
di Sanità (National Institute of Health), Rome, Italy
STEFANO DI MUCCIO • Department of Environmental Quality Monitoring, Istituto
Centrale per La Ricerca Scientifica e Tecnologica Applicata al Mare (Institute
for Scientific and Applied Marine Research), Rome, Italy
ELLEN DIJKMAN • Laboratory for Analytical Chemistry, National Institute
for Public Health and The Environment, Bilthoven, The Netherlands
FRANCISCO J. EGEA GONZÁLEZ • Department of Analytical Chemistry,
Faculty of Sciences, University of Almería, Almería, Spain
LUTZ ELFLEIN • Fraunhofer Institute of Toxicology and Experimental Medicine,
Hannover, Germany
MARC P. FERNANDEZ • Regional Contaminants Laboratory, Institute of Ocean Sciences,
Fisheries and Oceans Canada, Sidney, British Columbia, Canada
SILVIA FUSTINONI • Department of Occupational and Environmental Health, University
of Milan and Ospedale Policlinico, Mangiagallie Regina Elena, Milan, Italy
ANTONIA GARRIDO FRENICH • Department of Analytical Chemistry, Faculty
of Sciences, University of Almería, Almería, Spain
CRISTINA GIOVANNOLI • Dipartimento di Chimica Analitica, Università
di Torino, Torino, Italy
C. RICHARD GLASS • Environmental Biology Group, Central Science Laboratory,
York, UK
MANUEL J. GONZÁLEZ RODRÍGUEZ • Department of Analytical Chemistry,
Faculty of Sciences, University of Almería, Almería, Spain
WOLFGANG GRIES • Department SUA–GHA–GSS, Institute of Biomonitoring, Bayer
Industry Services GmbH and CoOHG, Leverkusen, Germany
ELBERT HOGENDOORN • Laboratory for Analytical Chemistry, National Instiute
for Public Health and The Environment, Bilthoven, The Netherlands
CHIA-SWEE HONG • Wadsworth Center, New York State Department
of Health, and School of Public Health, State University of New York
at Albany, Albany, NY
MICHAEL G. IKONOMOU • Regional Contaminants Laboratory, Institute of Ocean
Sciences, Fisheries and Oceans Canada, Sidney, British Columbia, Canada
ISABEL C. S. F. JARDIM • Departamento de Química Analítica, Instituto de Química,
Universidade Estadual de Campinas, Campinas, SP, Brazil
ROGER JEANNOT • Service Analyse et Caractérisation Minérale, BRGM, Orleans,
France
Contributors
xiii
HIROYUKI KATAOKA • Laboratory of Applied Analytical Chemistry, Department
of Biological Pharmacy, School of Pharmacy, Shujitsu University, Okayama,
Japan
DIETMAR KNOPP • Institute of Hydrochemistry and Chemical Balneology, Technical
University Munich, München, Germany
ANNA KOUKOURIKOU • Pesticide Science Laboratory, Aristotle University
of Thessaloniki, Thessaloniki, Greece
STEVEN J. LEHOTAY • Agricultural Research Service, US Department
of Agriculture, Eastern Regional Research Center, Wyndmoor, PA
GABRIELE LENG • Department SUA–GHA–GSS, Institute of Biomonitoring, Bayer
Industry Services GmbH and CoOHG, Leverkusen, Germany
MARIA J. LÓPEZ DE ALDA • Department of Environmental Chemistry,
IIQAB-CSIC, Barcelona, Spain
LIANA LUNGHINI • Unità Funzionale di Igiene Industriale e Tossicologia Occupazionale
(Department of Industrial Hygiene and Occupational Toxicology) Laboratorio
di Sanità Pubblica, Azienda USL 7 (Public Health Laboratory, National Health
Service Local Unit 7), Siena, Italy
M.-PILAR MARCO • Department of Biological Organic Chemistry,
IIQAB-CSIC, Barcelona, Spain
A. MARÍN • Department of Analytical Chemistry, Faculty of Sciences, University
of Almería, Almería, Spain
JOSÉ L. MARTÍNEZ VIDAL • Department of Analytical Chemistry, Faculty
of Sciences, University of Almería, Almería, Spain
FRANCISCO MERINO • Department of Analytical Chemistry, Faculty of Sciences,
University of Córdoba, Córdoba, Spain
KURIE MITANI • Laboratory of Applied Analytical Chemistry, Department
of Biological Pharmacy, School of Pharmacy, Shujitsu University, Okayama,
Japan
LARRY L. NEEDHAM • Centers for Disease Control and Prevention, National Center for
Environmental Health, Atlanta, GA
MIKAELA NICHKOVA • Department of Biological Organic Chemistry,
IIQAB-CSIC, Barcelona, Spain
KEVIN N. T. NORMAN • Central Science Laboratory, York, UK
M. FÁTIMA OLEA-SERRANO • Department of Nutritional and Food Sciences, University
of Granada, Granada, Spain
NICOLAS OLEA • Lab of Medical Investigations, Hospital Clínico, University
of Granada, Granada, Spain
ANDERS O. OLSSON • National Center for Environmental Health, Centers
for Disease Control and Prevention, Atlanta, GA
SEAN H. W. PANTON • Central Science Laboratory, York, UK
EMMANUIL NIKOLAOS PAPADAKIS • Pesticide Science Laboratory, Aristotle University
of Thessaloniki, Thessaloniki, Greece
EUPHEMIA PAPADOPOULOU-MOURKIDOU • Pesticide Science Laboratory, Aristotle
University of Thessaloniki, Thessaloniki, Greece
xiv
Contributors
JOHN PATSIAS • Aristotle Pesticide Science Laboratory, University
of Thessaloniki, Thessaloniki, Greece
JANUSZ PAWLISZYN • Department of Chemistry, University of Waterloo, Waterloo,
Canada
DOLORES PÉREZ-BENDITO • Department of Analytical Chemistry, Faculty
of Sciences, University of Córdoba, Córdoba, Spain
YOLANDA PICÓ • Laboratory of Bromatology and Toxicology, Faculty
of Pharmacy, University of Valencia, Valencia, Spain
JOSEANE M. POZZEBON • Departamento de Química Analítica, Instituto de Química,
Universidade Estadual de Campinas, Campinas, SP, Brazil
SONIA C. N. QUEIROZ • Laboratório de Dinâmica de Agroquímicos, Embrapa Meio
Ambiente, Jaguariúna, SP, Brazil
SARA RODRÍGUEZ-MOZAZ • Department of Analytical Chemistry, Faculty
of Sciences, University of Córdoba, Córdoba, Spain
SOLEDAD RUBIO • Department of Analytical Chemistry, Facultad De Ciencias, Edificio
Anexo Marie Curie, Córdoba, Spain
HASSAN SABIK • Food Research and Development Center, Agriculture
and Agri-Food Canada, St-Hyacinthe, Quebec, Canada
MITSUSHI SAKAMOTO • Tokushima Prefectural Institute of Public Health
and Environmental Sciences, Tokushima, Japan
GIANFRANCO SCIARRA • Unità Funzionale di Igiene Industriale e Tossicologia
Occupazionale (Department of Industrial Hygiene and Occupational Toxicology)
Laboratorio di Sanità Pubblica, Azienda USL 7 (Public Health Laboratory,
National Health Service Local Unit 7), Siena, Italy
CARLOS SONNENSCHEIN • Department of Anatomy and Cellular Biology, Tufts University
School of Medicine, Boston, MA
ANA M. SOTO • Department of Anatomy and Cellular Biology, Tufts University School
of Medicine, Boston, MA
MASAHIKO TAKINO • Yokogawa Analytical Systems Inc., Tokyo, Japan
TAIZOU TSUTSUMI • Tokushima Prefectural Institute of Public Health and
Environmental Sciences, Tokushima, Japan
KATINKA E. VAN DER JAGT • TNO Chemistry, Food and Chemical Risk Analysis, Zeist,
The Netherlands; currently, European Medicines Agency, London, UK
J EANETTE M. V AN E MON • Methods Development and Research Branch, National
Exposure Research Laboratory, US Environmental Protection Agency, Las
Vegas, NV
J OOP J. VAN H EMMEN • TNO Chemistry, Food and Chemical Risk Analysis, Zeist,
The Netherlands
ZISIS VRYZAS • Pesticide Science Laboratory, Aristotle University of Thessaloniki,
Thessaloniki, Greece
JI Y. ZHANG • GlaxoSmithKline, King of Prussia, PA
Endocrine Disrupter Pesticides by GC–MS/MS
3
1
Analysis of Endocrine Disruptor Pesticides in Adipose Tissue
Using Gas Chromatography–Tandem Mass Spectrometry
Assessment of the Uncertainty of the Method
José L. Martínez Vidal, Antonia Garrido Frenich,
Francisco J. Egea González, and Francisco J. Arrebola Liébanas
Summary
A multiresidue method based on extraction with organic solvents, cleanup by preparative liquid chromatography, and detection by gas chromatography (GC) using tandem mass spectrometry (MS/MS) mode is described for the determination of α- and
β-endosulfan and three main metabolites (sulfate, ether, and lactone) in human adipose
tissue samples. The analytical methodology is verified, and the values of some performance characteristics, such as linearity, limit of detection (LOD), limit of quantification
(LOQ) limits, precision (intraday and interday), and accuracy (recovery) are calculated.
The high efficiency of the cleanup step for the elimination of interference allows reaching detection limits at low micrograms per kilogram (parts per billion, ppb) concentration levels. In addition, an estimation of measurement uncertainty, using validation data,
is presented for each target compound. The results show that the sources of largest uncertainty are those relative to the balance calibration, from the gravimetric step, and both
the relative uncertainty associated with the recovery and the intermediate precision of
the method.
Key Words: Cleanup; endocrine disruptor; endosulfan; gas chromatography; metabolites; human adipose tissue; measurement uncertainty; organochlorine compounds;
pesticides; preparative liquid chromatography; tandem mass spectrometry.
1. Introduction
Organochlorine pesticides, such as endosulfan, are persistent environmental contaminants and tend to accumulate in humans and other animals (1,2). Endosulfan is
still widely used in agricultural activities in developed countries because of its low
relative persistence in comparison with other organochlorinated insecticides and its
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
3
4
Martínez Vidal et al.
excellent insecticidal action. However, endosulfan accumulates in adipose tissue along
the food chain because of its high stability and liposolubility. It is frequently found in
both environmental and biological samples (3–6). In addition, endosulfan has estrogenic effects on humans and is considered an endocrine-disrupting chemical (7–9).
Humans are exposed to endosulfan residues mainly in the workplace and through
diet. The best way to measure human exposure is the direct determination of its
residues in adipose tissue, although levels of organochlorine compounds in serum
are frequently used as indicators of total body burden. Obviously, serum is a more
accessible matrix for ascertaining residue levels of organochlorine compounds. However, a direct relationship between residues in serum and adipose tissue is not always
found (10,11).
The technical product of endosulfan is a mixture of two isomers, α- and β-endosulfan, that is metabolized by oxidation routes within the organisms, yielding metabolic compounds such as endosulfan sulfate, alcohol, ether, or lactone. As a
consequence, reliable analytical methodologies are necessary for determination of
endosulfan and its metabolites in human adipose tissue to ascertain exposure levels
and avoid effects on public health. Generally, effective solvent extraction methods
followed by cleanup steps and gas chromatographic (GC) determination are applied
to the determination of nonpolar pesticide residues in complex biological samples (4–
6,12–20). Mass spectrometry (MS), especially the tandem MS/MS operation mode, is
the preferred detection technique because it allows the identification, quantitation,
and confirmation of the detected residues. In addition, the use of MS/MS improves
the sensitivity and selectivity of the technique with a drastic reduction of the background and without losing identification capability. Most matrix interferences are
avoided, and the target compounds are identified by their secondary spectra by comparison with MS/MS libraries.
It is now recognized that analytical results cannot be acceptable without calculating
the measurement uncertainty (21), which is the confidence that can be placed in the
result. Formally, uncertainty is defined as a value associated with the result of a measurement that characterizes the dispersion of the values that could reasonably be attributed to the measurand (22). Uncertainty can be expressed in two different forms,
standard and expanded. The standard uncertainty u(xi) corresponds with the uncertainty of the result xi of a measurement expressed as a standard deviation. When the
standard uncertainty of the result y of a measurement derives from different sources of
uncertainty, it is referred to as combined standard uncertainty uc(y). It is equal to the
positive square root of a sum of terms. The expanded uncertainty U represents an
interval around the measurement result, which contains the unknown true value with a
defined probability. U is obtained by multiplying u(y) by a coverage factor k (23).
Three approaches are proposed for the estimation of the uncertainty: bottom-up
(23,24), top-down (21,25), and in-house validation methods (26,27). The bottom-up
method estimates each individual uncertainty for every step of the measurement process and obtains the combined standard uncertainty from the sum of each contribution
(28–30). The top-down method is based in the use of interlaboratory information
(30,31), and the third approach considers the information obtained from in-house validation of analytical methods (32).
Endocrine Disrupter Pesticides by GC–MS/MS
5
This chapter describes the simultaneous determination of α- and β-endosulfan and
their metabolites sulfate, ether, and lactone in human adipose tissue samples by gas
GC coupled to MS/MS, including the evaluation of the uncertainty of the method to
determine the critical steps of the analytical process. For this aim, a combination of the
bottom-up approach with in-house validation data for estimating the uncertainty of
each stage of the analytical method is used (5,17,33–36).
2. Materials
1.
2.
3.
4.
5.
6.
7.
Ultrapure water is prepared by distillation and then by Milli-Q SP treatment.
Pesticide quality solvents n-hexane, methanol, diethyl ether, and 2-propanol.
Standards of the pesticides with purity higher than 99% (see Note 1).
Heptachlor (purity 99%) used as internal standard (ISTD) (see Notes 1 and 2).
Ultrahigh purity helium (minimum purity 99.999%).
Alumina (Al2O3) (Merck, Darmstadt, Germany) 90 (70–230 mesh) no. 1097 (see Note 3).
Liquid chromatograph (e.g., Waters 990, Milford, MA) with a constant-flow pump (e.g.,
Waters 600 E) and a Rheodyne six-port injection valve with a 1-mL sample loop.
a. Ultraviolet-visible photodiode array detector (e.g., Waters 990).
b. Software for data acquisition and data analysis (e.g., Waters 991).
c. Liquid chromatographic (LC) column: 250 mm long × 4 mm id, 5 µm particle size
(e.g., Lichrospher Si column from Merck).
8. Gas chromatograph (e.g., Varian 3800, Sunnyvale, CA) with a split/splitless programmed
temperature injector and an autosampler (e.g., Varian Model 8200).
a. Ion trap mass spectrometer (e.g., Saturn 2000 from Varian).
b. Software for data acquisition and data analysis (e.g., Saturn 2000 from Variant), including an MS/MS library especially created for the target analytes in our experimental conditions (see Note 4).
c. GC capillary column: 30 m long × 0.25 mm id × 0.25 µm film thickness (e.g., DB5MS, J&W Scientific, Folsom, CA).
3. Methods
3.1. Preparation of Stock Solutions
1. Primary solutions: Weigh 50 mg of each pesticide standard and of the ISTD into a 100mL volumetric flask and fill the flask with n-hexane to the level (see Notes 5 and 6).
2. Secondary solutions: Make a 1:100 dilution with n-hexane to obtain a work solution containing all the target pesticides (see Notes 5 and 7). Make also a 1:100 dilution with nhexane of the primary ISTD solution (see Note 7).
3. Dilute the secondary solution with n-hexane to obtain the GC calibration solutions (the
standards) in the 1.0- to 250-µg/L range with each containing 100 µg/L of the secondary
solution of the ISTD (see Note 8).
3.2. Extraction
1. Weigh 500 mg of adipose tissue sample and extract five times with 4 mL of n-hexane and
shake in a vortex mixer for 1 min.
2. Pass the extract through the alumina column (see Note 3). Next, preconcentrate the eluate
at reduced pressure and then under a stream of nitrogen at 40°C and adjust the final residue to 1 mL with n-hexane.
6
Martínez Vidal et al.
Table 1
MS/MS Parameters
Pesticide
Activation
Time
(min)
m/z
Range
Endosulfan-ether
ISTD
Endosulfan-lactone
α-Endosulfan
β-Endosulfan
Endosulfan-sulfate
13.5–15.0
15.0–16.5
16.5–19.0
19.0–20.5
20.5–24.5
20.5–24.5
85–280
85–290
85–330
85–250
85–290
85–290
Excitation
Amplitude
(V)
77
80
92
81
79
62
Excitation
storage
Level
(m/z)
80
100
141
80
80
80
3.3. Instrumental Conditions
3.3.1. High-Performance Liquid Chromatographic System
The mobile phase, under gradient conditions, is as follows: initially 2-min isocratic
gradient with 100% phase A (n-hexane); 15-min linear gradient to 60% phase A, 40%
phase B (n-hexane:methanol:2-propanol, 40:45:15 v/v); 20-min linear gradient to
100% phase B; and 30-min linear gradient to 100% phase A. An additional time of 5
min with this composition of mobile phase is enough to return the system to the initial
conditions for subsequent analysis. The mobile phase is set at a flow rate of 1 mL/min,
and the diode array detector is used at 280 nm for monitoring lipid elution on-line. The
fraction corresponding to the first 11 min (see Note 9) eluting from the high-performance liquid chromatographic (HPLC) system is collected, dried under a nitrogen
stream, and eluted with 1 mL of n-hexane (see Note 10). Of this extract, 2 µL are
injected into the GC–MS/MS instrument.
3.3.2. GC System
The GC has a septum-equipped, temperature-programmable injector that is initially
held at 90°C for 0.1 min before ramping to 280°C at a rate of 200°C/min. The GC oven
is initially held at 80°C for 2.5 min, then ramped at 50°C/min to 140°C, and finally
from 140°C is increased at 5°C/min to 260°C and held for 3 min. The ion trap mass
spectrometer is operated in the electron ionization mode, and the MS/MS option is
used. The GC–MS conditions are as follows: 11-min solvent delay; 70-eV electron
impact energy; 0.6-scans/s scan rate; 85–450 scanned range m/z. The transfer line is
kept at 260°C and the ion trap manifold at 200°C. The automatic gain control is
switched on with a target fixed at 5000 counts. Helium at a flow rate of 1 mL/min is
used as the carrier and collision gas. The MS/MS parameters are shown in Table 1.
3.4. Cleanup
Inject 1 mL of the final residue in n-hexane into the HPLC system. Collect the
fraction corresponding to the first 11 min (see Note 9) eluting from the HPLC system,
dry under a nitrogen stream, and elute with 1 mL of n-hexane (see Note 10). Inject 2
µL of this extract into the GC–MS/MS instrument.
Endocrine Disrupter Pesticides by GC–MS/MS
7
Fig. 1. GC–MS/MS chromatogram of a standard solution of the target pesticides in n-hexane at 100 µg L-1: 1, endosulfan-ether; 2, ISTD; 3, endosulfan-lactone; 4, α-endosulfan; 5, βendosulfan; and 6, endosulfan-sulfate.
3.5. GC–MS/MS Analysis
3.5.1. Verification of the Analytical Method (see Note 11)
1. Inject 2-µL aliquots of the GC calibration solutions, each containing 100 µg/L of the
ISTD. Figure 1 shows a chromatogram of a mixture containing the target pesticides and
the ISTD.
2. Check the linearity of the detector response over the concentration range 1.0–250 µg/L
(see Note 12) using relative areas of the target compounds to the internal standard. The
correlation coefficients must have a minimum value of 0.99.
3. Inject, 10 times, 2-µL aliquots of a GC calibration solution containing 100 µg/L of the
ISTD to calculate the retention time windows (RTWs) (see Note 13).
4. Check the selectivity, or the existence of potential interference in the chromatograms
from the biological samples, by running blank samples in each calibration (see Note 14).
5. Obtain the reference spectrum, used for the confirmation of positive results in the analysis of real samples, by analyzing 10 blank spiked samples (see Note 15) at the 200-µg/kg
concentration level (see Note 16).
6. Check the limit of detection (LOD) and limit of quantification (LOQ), calculated as 3 and
10 times the respective standard deviation (10 injections) of the baseline signal corresponding to a blank matrix extract chromatogram at the analyte retention times divided
by the respective slopes of the calibration curves of the analytes (see Note 17).
8
Martínez Vidal et al.
7. Check the recovery of the target pesticides and the intraday and interday precision of
spiked samples (see Notes 15 and 18). The extraction recovery of target pesticides is
determined by comparing the peak area ratios (for the analytes relative to the ISTD) in
samples spiked with the analytes prior to extraction with those for samples to which the
analyte is added postextraction (see Note 19). The intraday precision, or repeatability,
and the interday precision, or intermediate precision, are estimated by the analysis of
different aliquots (n = 5) of the same spiked sample within day or between days (five
different days), respectively (see Note 20).
3.5.2. Sample Analysis (see Note 21)
1. Inject 2 µL of the last extract obtained, redissolving with 1 mL of n-hexane the fraction
eluted from the HPLC system, after drying, and run the chromatogram.
2. Integrate the chromatogram and report the compounds detected and its peak area.
3. Identify the pesticides detected using the RTW values, which means that the retention
time of the compound must be in the previously established RTW when the method is
verified.
4. Quantify the positive results by the ITSD method. The value V of the target compound in
the analyzed sample is calculated according to the following expression:
C
V(µg / Kg ) = Vf
m
where C is the analytical concentration obtained from the analytical curve, m is the mass
of adipose tissue sample, and Vf is the sample dilution volume for analysis.
5. The confirmation of the previously identified compound can be made by comparing the
MS/MS spectrum obtained in the sample with another stored as a reference spectrum in
the same experimental conditions (see Note 22). If the fit value is higher than the threshold fit value previously established (see Note 16), the compound is positively confirmed.
6. Express the result with the uncertainty (U), that is, as R ± U.
3.5.3. Assessment of the Uncertainty of the Measurement
The estimation of the uncertainty, a validation parameter, it is explained in more
depth because it is less known. In estimating the overall uncertainty, the main sources
of uncertainty have to be identified and separately studied to obtain its contribution. In
the present method, the components are (1) the gravimetric step ur(g) and (2) the
chromatographic quantification step, which comprises two components: statistical
evaluation of the relative uncertainty associated with recovery ur(crecovery) and that
associated with the repeatability of the method ur(ip).
1. Gravimetric step. This step results from the combination of the following three components:
a. The relative reference standard uncertainty ur(s):
Tolref
2
u r (s) =
m
where Tolref represents the tolerance of the reference standard given by the supplier,
and m represents the weight of the reference standard.
Endocrine Disrupter Pesticides by GC–MS/MS
9
b. The relative balance calibration standard uncertainty ur(b):
Tolbal
2
ur (b) =
m
where Tolbal represents the reported tolerance of the balance for the range used. This
source of uncertainty is counted twice because the weighing process involves a difference.
c. The gravimetric sample relative uncertainty ur(ms):
Tol s
3
ur (ms ) =
ms
where Tols represents the reported tolerance of the balance for the range used, and ms
represents the weight of the adipose tissue sample (500 mg).
The components are combined into the following equation (23):
u r (g ) =
[ u r ( s ) ]2 + [ u r
( b )]2 ⋅ 2+ u r ( m s ) 2
2. Chromatographic quantification step, which results from the combination of the following two sources:
a. Statistical evaluation of relative uncertainty associated with recovery from 10 equal
quantities of the sample matrix spiked at a single concentration level (200 mg/kg) and
analyzed intraday ur(crecovery). It results from the combination of two components:
The first is the relative uncertainty associated with the calibration curve ur(cal)
1/ 2
s res 2
2
s
b
+ d c2 ⋅ b
b
n
u r ( cal) =
cc
where sres is the residual standard deviation of the calibration curve, sb is the standard
deviation of the calibration curve, b is the calibration curve slope, n is the number of
the calibration standards, and dc is the difference between the average concentration
of the calibration standards and the representative concentration (100 µg/L) of the
sample cc. The second is the relative uncertainty associated with the repeatability of
the method ur(rep)
SDrep
n
rep
u r ( rep ) =
Rrep
10
Martínez Vidal et al.
where SDrep represents the standard deviation from the recoveries obtained of the
replicate analyses, nrep is the number of replicates analyzed, and R rep is the mean
recovery obtained.
Both sources are combined into the equation:
u r ( c recovery ) =
[ur ( cal )]2 + ur ( rep ) 2
b. Statistical evaluation of the relative uncertainty associated with the intermediate precision of the method and calculated from 10 equal quantities of the sample matrix
spiked at the same single concentration level (200 µg/kg) and analyzed interday ur(ip).
SDip
n
ip
u r ( ip ) =
Rip
where SDip represents the standard deviation from recoveries obtained of replicate
analyses, nip is the number of replicates analyzed, and R ip is the mean of the recovery obtained.
3. Calculation of combined and expanded uncertainty. Once the parameters and their associated uncertainties that contribute to the uncertainty for the method as a whole are listed,
the individual uncertainties are combined in the uncertainty budget to give uc(y):
u c ( y ) = u r ( g ) + u r ( c recovery ) + u r ( ip )
2
2
2
The expanded uncertainty U is obtained by multiplying uc(y) by a coverage factor k,
assuming a normal distribution of the measurand. The choice of this factor is based on the
level of confidence desired. Usually, a value of k = 2 is used, which provides an approximate level of confidence of 95%.
U=u c ( y ) ⋅k
F2
4. The quantification of these sources (see Note 23) showed that, in the selected experimental conditions, the largest sources of uncertainty were the ur(b) from the gravimetric step
and the ur(crecovery) and ur(ip) from the chromatographic quantification step (see Note
24). Figure 2 shows the contributions to the measurement uncertainty for endosulfan-β.
U values lower than 24% are obtained for all the pesticides.
4. Notes
1. Standards of the pesticides and the ISTD must be kept in the refrigerator (approx 2–4°C).
Owing to their toxicity, some precautions in relation to contact with skin and eyes and
inhalation must be observed.
2. Heptachlor is recommended for ISTD because it is not encountered in biological samples
and does not coelute with target pesticides during GC separation.
Endocrine Disrupter Pesticides by GC–MS/MS
11
Fig. 2. Contributions to the measurement uncertainty for the determination of β-endosulfan
in an adipose tissue sample.
3. Alumina activated at 600°C can be stored at room temperature for up to 6 mo. For gravity
flow elution of the chlorinated pesticides, a deactivation of approx 5% water has been
found to be satisfactory for alumina. For that, pipet 100 µL of distilled water into an
Erlenmeyer flask. Rotate the flask gently to distribute water over its surface. Add 2 g of
activated alumina and shake the flask containing the mixture for 10 min on a mechanical
shaker. Prepare cleanup columns by plugging the glass column (15 cm long × 0.5 cm id)
with a small wad of glass wool. Add 1 g of granular anhydrous Na2SO4 and then the 2 g of
deactivated alumina.
4. A parent ion is chosen for each analyte, from its full scan spectra, by taking into consideration its m/z and its relative abundance (both as high as possible) to improve sensitivity.
The parent ions selected of the target analytes are the following typical values: 239 for
endosulfan-ether, 272 for the ISTD, 321 for endosulfan-lactone, 239 for endosulfan-α,
239 for endosulfan-β, and 272 for endosulfan-sulfate. Next, the selected ions are subjected to collision-induced dissociation to obtain secondary mass spectra. The object is to
generate spectra with the parent ion as their molecular peaks (between 10 and 20% of
relative abundance). The MS/MS spectra of the pesticides in our experimental conditions
are stored in our own electron ionization MS/MS library.
5. All standards should be prepared in clean, solvent-rinsed volumetric glassware (A class)
and stored in a freezer when not in use.
6. If kept in the refrigerator, the primary stock solutions of the target pesticides and the
ISTD (approx 2–4°C) can be used for at least 6 mo.
7. If kept in the refrigerator at 4°C, the secondary solutions may be used for at least 1 mo.
8. The calibration solutions are stable at ambient temperature up to at least 24 h.
9. Three pooled fractions (α, x, and β) can be separated by HPLC. The α-fraction is collected in the first 11 min, the x fraction is collected between minutes 11 and 13, and the βfraction is collected between minutes 13 and 25. Xenoestrogens, such as the target
organochlorinated compounds, elute in fraction α; natural estrogens elute in fraction β.
Neither xenoestrogens nor natural estrogens are detected in fraction x.
10. Do not forget to add the ISTD to this 1 mL. The use of the ISTD increases the repeatability of the analytical signal measured into the GC–MS/MS.
12
Martínez Vidal et al.
11. Internal method validation is the first step before the application of an analytical method.
It consists of the validation steps carried out within one laboratory to verify that the measurement chemical process is under statistical control and to ensure that the method is “fit
to purpose.” For this aim, performance characteristics such as accuracy, precision, detection limit, quantification limit, linear range, or selectivity must be checked. The values of
these validation parameters will depend on the instrument, column, environmental conditions, and so on for the analytical laboratory in which they are obtained. In this chapter,
we present the values obtained in our laboratory.
12. Five calibration standards are prepared with the following concentrations: 1, 25, 50, 100,
and 250 µg/L. Calibration standards must be injected in triplicate if higher precision in
the calibration step is desired. In this case, the calibration curve is obtained using all the
values at each concentration level.
13. The RTWs are calculated as the average of the retention times plus or minus three standard deviations of the retention times for 10 measurements. RTW values of 20.64–21.42
min for endosulfan-ether, 23.39–24.20 min for the ISTD, 27.96–28.89 min for endosulfan-lactone, 34.23–35.24 min for α-endosulfan, 39.95–41.06 min for β-endosulfan, and
45.37–46.51 min for endosulfan–sulfate are typical values obtained.
14. The absence of any chromatographic component at the same retention times as target
pesticides indicates that no chemical interference is occurring. It must be mentioned that
the MS/MS detection mode can determine up to six compounds that coelute.
15. In the fortification step, it is necessary to use a volume of standard as low as possible; to
be sure that the spiked sample is homogenized; and to let the spiked sample dry at least
for 30 min before extraction.
16. From the 10 spectra obtained for each compound under the same analysis conditions,
select 1 as a reference spectrum and compare the other 9 spectra with it. The product of
the comparison is 9 fit values (from 0 to 1000 for best match) and an average fit value. A
threshold fit value is obtained by subtracting three times the value of the standard deviation (estimated from the 9 fit values) to the average fit. This subtraction is done to compensate for the spectral variation caused by the routine analysis of samples, which dirty
the instrument and require maintenance operations that would slightly affect the detector
response and therefore the spectra.
17. LOD (LOQ) limits in the matrix of about 0.4 (2) µg kg-1 for endosulfan-ether, 1.2 (4)
µg kg-1 for endosulfan-lactone, 2.4 (8) µg kg-1 for α-endosulfan, 5 (16) µg kg-1 for βendosulfan, and 1.6 (6) µg kg-1 for endosulfan-sulfate are easily obtained. These limits
are sufficiently low for the trace analysis of the target pesticide residues in human
adipose samples.
18. The use of samples spiked with target compounds is necessary to carry out reliable studies about the recovery achieved by the procedure because of the lack of certified reference samples.
19. Recoveries must be between 65 and 120% for adipose tissue samples spiked with 40–200
µg kg-1.
20. Intraday precision and interday precision, as measured by relative standard deviation,
must be lower than 10 and 20%, respectively.
21. Laboratory reagents blank, laboratory spiked blank, and a calibration curve must be analyzed with each set of real samples. The laboratory reagents blank checks any interference contamination caused by reagents during processing samples. Analyses of samples
are carried out if recoveries of laboratory-spiked blanks are between 60 and 130%.
Endocrine Disrupter Pesticides by GC–MS/MS
13
22. The reference spectrum is obtained during the verification process (see Note 17). The
results of this comparison (fit) allow checking that the spectra obtained have not changed
since the verification process. The fit value obtained in this comparison must be higher
than the threshold fit value established (see Note 17).
23. We have not taken into account the contribution to uncertainty corresponding to the dilution of the primary standard. Our experience in this field allows us to conclude that the
contribution of this step is not significant.
24. Obviously, to decrease the uncertainty of the method, it would be adequate to act on the
components with a high contribution [ur(b), ur(crecovery), and ur(ip)]. On one hand, increasing the amount of sample weighed for the analysis or the amount of solid standard
weighed for the preparation of primary standard solution. On the other hand, ur(crecovery)
and ur(ip) by trying to improve the precision of the method or to increase the concentration levels or the number of calibration points.
References
1. Barr, D. B. and Needham, L. L. (2002) Analytical methods for biological monitoring of
exposure to pesticides: a review. J. Chromatogr. A 778, 5–29.
2. Strandberg, B., Strandberg, L., Bergqvist, P. A., Falandysz, J., and Rappe, C. (1998) Concentrations and biomagnification of 17 chlordane compounds and other organochlorines
in harbour porpoise (Phocoena phocoena) and herring from the southern Baltic Sea.
Chemosphere 7, 2513–2523.
3. Garrido Frenich, A., Pablos Espada, M. C., Martínez Vidal, J. L., and Molina, L. (2001)
Broad spectrum analysis of pesticides in groundwater samples by gas chromatography
with ECD, NPD and MS/MS detectors. J. AOAC, 84, 1–12.
4. Martínez Vidal, J. L., Moreno Frías, M., Garrido Frenich, A., Olea-Serrano, F., and Olea,
N. (2000) Trace determination of α and β endosulfan and three metabolites in human
serum by GC–ECD and GC–MS–MS. Rapid Commun. Mass Spectrom. 14, 939–946.
5. Martínez Vidal, J. L., Moreno Frías, M., Garrido Frenich, A., Olea-Serrano, F., and Olea,
N. (2002) Determination of endocrine-disrupting pesticides and polychlorinated biphenyls in human serum by GC–ECD and GC–MS/MS and evaluation of the contributions to
the uncertainty of the results. Anal. Bioanal. Chem. 372, 766–775.
6. Hernández, F., Pitarch, E., Serrano, R., Gaspar, J. V., and Olea, N. (2002) Multiresidue
determination of endosulfan and metabolic derivatives in human adipose tissue using automated liquid chromatographic cleanup and gas chromatographic analysis. J. Anal.
Toxicol. 26, 94–103.
7. Soto, A. M., Chung, K. L., Sonnenschein, C. (1994) The pesticides endosulfan, toxaphene,
and dieldrin have estrogenic effects on human estrogen-sensitive cells. Environ. Health
Perspect. 102, 380–383.
8. Olea, N., Pazos, P., and Exposito, J. (1998) Inadvertent exposure to xenoestrogenes. Eur.
J. Cancer Prev. 7(Suppl. 1), S17–S23.
9. Gascón, J., Oubiña, A., and Barceló, D. (1997) Detection of endocrine-disrupting pesticides by enzyme-linked immunosorbent assay (ELISA): application to atrazine. Trends
Anal. Chem. 16, 554–562.
10. Aronson, K. J., Miller, A. B., Woolcott, C. G., et al. (2000) Breast adipose tissue concentrations of polychlorinated biphenyls and other organochlorines and breast cancer risk.
Cancer Epidemiol. Biomarkers Prev. 9, 55–63.
14
Martínez Vidal et al.
11. Kohlmeier, L. and Kohlmeier, M. (1995) Adipose tissue as a medium for epidemiology
exposure assessment. Environ. Health Perspect. 103, 99–106.
12. Ludwicki, J. L. and Goralczyk, K. (1994) Organochlorine pesticides and PCBs in human
adipose tissues in Poland. Bull. Environ. Contam. Toxicol. 52, 400–403.
13. Asakawa, A., Jitsunari, F., Shiraishi, H., Suna, S., Takeda, N., and Kitamado, T. (1996)
Accumulation of chlordanes in adipose tissues of mice caused by long exposure of low
level technical chlordane. Bull. Environ. Contam. Toxicol. 57, 909–916.
14. Bucholski, K. A., Begerow, J., Winneke, G., and Duneman, L. (1996) Determination of
polychlorinated biphenyls and chlorinated pesticides in human body fluids and tissues. J.
Chromatogr. A 754, 479–485.
15. Garrido Frenich, A., Martínez Vidal, J. L., Moreno Frías, M., Olea-Serrano, F., and Olea,
N. (2000) Quantitative determination of endocrine-disrupting polychlorinated biphenyls
and organochlorinated pesticides in human serum using GC/ECD and tandem mass spectrometry. J. Mass Spectrom. 35, 967–975.
16. Moreno Frías, M., Garrido Frenich, A., Martínez Vidal, J. L., Olea, F., Olea, N., and Mateu,
M. (2001) Analysis of endocrine-disrupting compounds lindane, vinclozolin, aldrin, p-p′
DDE, p-p′ DDT in human serum using GC–ECD and tandem mass spectrometry. J.
Chromatogr. B 760, 1–15.
17. Moreno Frías, M., Garrido Frenich, A., Martínez Vidal, J. L., et al. (2003) Determination
of endocrine disrupting pesticides in serum by GC–ECD and GC–MS/MS techniques including an evaluation of the uncertainty associated with the results. Chromatographia 57,
213–220.
18. Moreno Frías, M., Jiménez Torres, M., Garrido Frenich, A., Martínez Vidal, J. L., OleaSerrano, F., and Olea, N. (2004) Determination of organochlorine compounds in human
biological samples by GC–MS/MS. Biomed. Chromatogr. 18, 102–111.
19. Pauwels, A., Wells, D. A., Covaci, A., and Schepens, P. J. C. (1999) Improved sample
preparation method for selected persistent organochlorine pollutants in human serum using solid-phase disk extraction with gas chromatographic analysis. J. Chromatogr. B 723,
117–125.
20. Röhrig, L. and Meisch, H.-U. (2000) Application of solid phase micro extraction for the
rapid analysis of chlorinated organics in breast milk. Fresenius J. Anal. Chem. 366, 106–111.
21. Analytical Methods Committee. (1995) Uncertainty of measurement—implications for its
use in analytical science. Analyst 120, 2303–2308.
22. International Organization for Standardization. (1993) International Vocabulary of Basic
and General Terms in Metrology, International Organization for Standardization, Geneva.
23. International Organization for Standardization. (1993) Guide for the Expression of Uncertainty in Measurements, International Organization for Standardization, Geneva.
24. EURACHEM Guide. (2000) Quantifying uncertainty in analytical measurement, 2nd ed.,
http//www.vtt.fi/ket/eurachem/quam2000-p1.pdf.
25. Wernimont, G. T. (1985) Use of Statistics to Develop and Evaluate Analytical Methods,
AOAC, Arlington, V.A.
26. Thompson, M., Ellison, S. L. R., Wood, R. (2002) Harmonized guidelines for singlelaboratory validation of methods. Pure Appl. Chem. 74, 835–855.
27. Hill, A. R. and Reynolds, S. L. (1999) Guidelines for in-house validation of analytical
methods for pesticide residues in food and animal feeds. Analyst 124, 953–958.
28. Quintana, J., Martí, I., and Ventura, F. (2001) Monitoring of pesticides in drinking and
related waters in EN Spain with a multiresidue SPE–GC–MS method including an estimation of the uncertainty of the analytical results. J. Chromatogr. A 938, 3–13.
Endocrine Disrupter Pesticides by GC–MS/MS
15
29. Bettencourt da Silva, R. J. N., Santos, J. R., and Camöes, M. F. G. F. C. (2003) Evaluation of
the analytical method performance for incurred samples. Anal. Chim. Acta 485, 241–252.
30. Hund, E., Massart, D. L., and Smeyers-Verbeke, J. S. (2003). Comparison of different
approaches to estimate the uncertainty of a liquid chromatographic assay. Anal. Chim.
Acta 480, 39–52.
31. Dehouck, P., Vander Heyden, Y., Smeyers-Verbeke, J., et al. (2003) Determination of
uncertainty in analytical measurements from collaborative study results on the analysis of
a phenoxymethylpenicillin sample. Anal. Chim. Acta 481, 261–272.
32. Maroto, A., Boqué, R., Riu, J., and Rius, F. X. (1999) Evaluating uncertainty in routine
analysis. Trends Anal. Chem. 18, 577–584.
33. Maroto, A., Boqué, R., Riu, J., and Rius, F. X. (2000) Critical discussion on the procedures to estimate uncertainties in chemical measurements. Quim. Anal. 19, 85–94.
34. Bettencourt da Silva, R. J. N., Joäo Lino, M., Sanots, J. R., and Camöes, M. F. G. F. C.
(2000) Estimation of precision and efficiency mass transfer steps for the determination of
pesticides in vegetables aiming at the expression of results with reliable uncertainty. Analyst 125, 1459–1464.
35. Lisinger, T. P. J., Führer, M., Kandler, W., and Schuhmacher, R. (2001) Determination of
measurement uncertainty for thedetermination of triazines in groundwater from validation
data. Analyst 126, 211–216.
36. Cuadros-Rodriguez, L., Hernández Torres, M. E., Almansa López, E., et al. (2002) Assessment of uncertainty in pesticide multiresidue analytical methods: main sources and
estimation. Anal. Chim. Acta 454, 297–314.
Pyrethroids in Blood Plasma and Urine
17
2
Determination of Pyrethroids in Blood Plasma and Pyrethroid/
Pyrethrin Metabolites in Urine by Gas Chromatography–
Mass Spectrometry and High-Resolution GC–MS
Gabriele Leng and Wolfgang Gries
Summary
In this chapter, two analytical methods are presented suitable for the determination of
pyrethroids in blood plasma and pyrethroid/pyrethrin metabolites in urine. As pyrethroids
such as cyfluthrin, cypermethrin, deltamethrin, permethrin, and bioallethrin are metabolized very fast, they can only be detected within about 24 h after exposure; that is, the
method shown should only be applied in case of intoxication. After solid-phase extraction, the sample is analyzed by high-resolution gas chromatography–negative chemical
ionization mass spectrometry (HRGC–NCIMS) with a detection limit of 5 ng/L blood
plasma. In all other cases of exposure (occupational surveillance, environmental, biological monitoring programs, etc.), the determination of metabolites in urine by gas chromatography–mass spectrometry (GC–MS) or HRGC–MS should be preferred. The urine
method is adequate for the simultaneous determination of the pyrethroid metabolites cisand trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane carboxylic acid, cis-3-(2,2dibromovinyl)-2,2-dimethylcyclopropane carboxylic acid, 3-phenoxybenzoic, and 4fluoro-3-phenoxybenzoic acid as well as of the pyrethrin/bioallethrin-specific metabolite
trans-chrysanthemumdicarboxylic acid (-CDCA). After acid hydrolysis and sample extraction with tert-butyl-methylether, the residue is derivatized with 1,1,1,3,3,3hexafluoroisopropanol and analyzed by HRGC–MS (detection limit 0.1 µg/L urine).
Key Words: Bioallethrin; biomonitoring; blood plasma; cyfluthrin; cypermethrin;
deltamethrin; derivatization; insecticide; GC–MS; hexafluoroisopropanol; HRGC–
NCIMS; metabolites; permethrin; pyrethroids; pyrethrum; solid-phase extraction; -chrysanthemum-dicarboxylic acid; urine.
1. Introduction
Synthetic pyrethroids such as cyfluthrin, cypermethrin, deltamethrin, and
permethrin originate from the botanical insecticide pyrethrum, an extract obtained
from the flowers of Chrysanthemum cinerariaefolium. Pyrethrins as one of the natural
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
17
18
Leng and Gries
esters of pyrethrum, and the synthetic pyrethroids are among the insecticides most
often used worldwide.
In mammals, pyrethroid esters are rapidly detoxified by ester hydrolysis and hydroxylation, partially conjugated, and finally eliminated, mainly in the urine (Fig. 1).
The main metabolites are cis- and trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane
carboxylic acid (cis-DCCA and trans-DCCA), cis-3-(2,2-dibromovinyl)-2,2dimethylcyclopropane carboxylic acid (-DBCA), 3-phenoxybenzoic acid (3-PBA), and
4-fluoro-3-phenoxybenzoic acid (FPBA). The biological half-lives of the different
pyrethroids vary between 2.5 and 12 h in blood plasma (1–3). Half-lives of 6.44 h
were found for the urinary excretion of the metabolites cis-DCCA, trans-DCCA, and
FPBA after oral or inhalation exposure to cyfluthrin in volunteers. Of the metabolites,
94% were excreted renally during the first 48 h after exposure (4).
Chrysanthemate insecticides like natural pyrethrins or (S)-bioallethrin are also metabolized by hydrolysis, oxidation and finally conjugation with the major metabolite
eliminated in the urine (5,6). Figure 2 shows that the major metabolite is -(E)chrysanthemumdicarboxylic acid (trans-CDCA). Interestingly, cis-CDCA as well as
trans-chrysanthemic acid are not found in humans. Following (S)-bioallethrin exposure, maximum peak excretion of trans-CDCA was within the first 24 h after exposure, and 72 h later the concentration of trans-CDCA was below the limit of detection (6).
In humans, a variety of reversible symptoms, such as paraesthesia, irritations of the
skin and mucosa, headache, dizziness, and nausea, are reported following pyrethroid/
pyrethrin exposure (1,7,8). For these adverse health effects, the original pyrethroid/
pyrethrin and not the detoxified metabolites is responsible. Therefore, from the medical point of view, it is useful to determine the pyrethroid/pyrethrin in plasma. Exposure to high pyrethroid doses, as seen in cases of acute intoxication, leads to detectable
pyrethroid concentrations in blood plasma during the first hour after exposure, rapidly
decreasing within 24 h (9). In persons occupationally exposed to pyrethroids as well
as in persons exposed in their private surroundings, pyrethroid plasma levels are
always below the detection limit, although detectable amounts of metabolites can be
found in urine (10–12). Therefore, for routine biological monitoring of persons exposed to pyrethrins or pyrethroids, the determination of the corresponding metabolites
in urine is most often described in literature (4,9–16).
1.1. Determination of Pyrethroids in Blood Plasma
With the method described here, all relevant pyrethroids (i.e., cyfluthrin,
cypermethrin, deltamethrin, permethrin, and bioallethrin) can be determined in 1 mL
blood plasma (see Note 1). After cleanup, sample enrichment with solid-phase extraction and elution with hexane/dichloromethane, the sample is analyzed by high-resolution
gas chromatography–negative chemical ionization mass spectrometry (HRGC–NCIMS)
(5 ng/L blood plasma detection limit) (see Note 2). The analysis in negative chemical
ionization (NCI or CI-) mode is more sensitive than the most-often-used positive electron impact (EI+) mode. This is based on the weaker ionization process in NCI and results
in lower mass fragmentation, which enables lower detection limits.
Pyrethroids in Blood Plasma and Urine
19
19
Fig. 1. Metabolism of the pyrethroids cyfluthrin, cypermethrin, deltamethrin, and permethrin in humans. The corresponding metabolites
found in urine are shown in brackets. cis-DCCA and trans-DCCA: cis- and trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane carboxylic
acid; cis-DBCA: cis-3-(2,2-dibromovinyl)-2,2-dimethylcyclopropane carboxylic acid; 3-PBA: 3-phenoxybenzoic; FPBA: 4-fluoro-3phenoxybenzoic acid.
20
Leng and Gries
Fig. 2. Metabolism of (S)-bioallethrin in humans.
1.2. Determination of Pyrethrin/Pyrethroid Metabolites (cis/trans CDCA,
cis/trans-DCCA, cis-DBCA, FPBA, 3-PBA) in Urine
This method is developed for the simultaneous determination of the metabolites of
synthetic pyrethroids (cis-DCCA, trans-DCCA, cis-DBCA, 3-PBA, and FPBA)
together with the metabolite of pyrethrin chrysanthemumdicarboxylic acid (transCDCA) (see Note 3). After acid hydrolysis, the sample is derivatized with 1,1,1,3,3,3-
Pyrethroids in Blood Plasma and Urine
21
Fig. 3. Esterification of CDCA with 1,1,1,3,3,3-hexafluoroisopropanol.
hexafluoroisopropanol (HFIP) in the presence of N,N'-diisopropylcarbodiimide (DIC).
Detection is done by HRGC–MS after separation on a Rtx 65 fused silica capillary
column (0.1 µg/L urine detection limit) (see Note 4).
The reaction scheme of CDCA esterification with hexafluoroisopropanol is shown
in Fig. 3.
2. Materials
2.1. Determination of Pyrethroids in Blood Plasma
1. Microliter pipets, adjustable between 1 and 1000 µL (e.g., Eppendorf, Hamburg, Germany).
2. 10-mL tubes with Teflon-sealed screw caps.
3. Nitrogen evaporator.
4. Microvials (e.g., Agilent, Palo Alto, CA).
5. Microevaporator unit.
6. Solid-phase extraction (SPE) column station with column drying option (e.g., Supelco,
Bellefonte, PA).
7. Oasis HLB [hydrophilic–lipophilic balance] cartridges, 6 mL/200 mg (Waters, Milford, MA).
8. GC–MS system with NCI equipment (e.g., AutoSpec Ultima, Micromass/Waters,
Milford, MA).
9. Helium 5.0.
10. Capillary column, 30 m × 0.25 mm × 0.1 µm DB5 (Durabond 5; Agilent).
11. Cyfluthrin (e.g., Dr. Ehrenstorfer GmbH, Augsburg, Germany).
12. Deltamethrin (e.g., Dr. Ehrenstorfer).
13. Cypermethrin (e.g., Dr. Ehrenstorfer).
14. Permethrin (e.g., Dr. Ehrenstorfer).
15. Bioallethrin (e.g., Dr. Ehrenstorfer).
16. Fenvalerat (e.g., Dr. Ehrenstorfer), used as internal standard (ISTD).
17. Dichloromethane (Supra-Solv).
18. Hexane (Supra-Solv).
19. Methanol (Supra-Solv).
20. For conditioning of Oasis HLB cartridges, First wash each column with 4 mL methanol at
atmospheric pressure. After methanol is rinsed through the column, repeat the same procedure with 6 mL water.
21. To prepare the standard solutions, about 10 mg of each compound (or proportionally
more if purity < 100%) is weighed into separate 10-mL flasks. Each flask is diluted to
volume with acetonitrile. The concentration of these standard starting solutions is 1000
mg/L. The following dilutions were performed with these starting solutions.
22
Leng and Gries
Table 1
Necessary Fortification Levels for Pyrethroids in Blood Plasma
Concentration
(µg/L)
Blank value
0.01
0.02
0.05
0.10
0.20
0.50
1.00
Stock solution
—
4
4
4
3
3
3
2
Spike volume (µL)
in 1 mL plasma
—
10
20
50
10
20
50
10
Spike volume
ISTD dilution
0.1 mg/L
(µL)
10
10
10
10
10
10
10
10
a. For stock solution 1 of 1.0 mg/L, 100 µL of each standard starting solution is added to
a 100-mL flask, which is filled to volume with acetonitrile (1:1000 dilution).
b. For stock solution 2 of 0.1 mg/L, 1000 µL of stock solution 1 is added to a 10-mL
flask, which is filled to volume with acetonitrile (1:10,000 dilution).
c. For stock solution 3 of 0.01 mg/L, 100 µL of stock solution 1 is added to a 10-mL
flask, which is filled to volume with acetonitrile (1:100,000 dilution).
d. For stock solution 4 of 0.001 mg/L, 100 µL of dilution 2 is added to a 10-mL flask,
which is filled to volume with acetonitrile (1:1,000,000 dilution).
e. For ISTD solution of 0.1 mg/L, preparation is done with separate dilutions in comparison to stock solution 2 described in a above.
For the calibration experiment, defined volumes of dilution 1, 2, 3, or 4 are added to
1 mL plasma. The dilutions for necessary concentrations are shown in Table 1.
2.2. Determination of Pyrethrin/Pyrethroid Metabolites
(cis-/trans-CDCA, cis-/trans-DCCA, cis-DBCA, FPBA, 3-PBA) in Urine
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Microliter pipets, adjustable between 1 and 2000 µL (e.g., Eppendorf).
20-mL tubes with Teflon-sealed screw caps.
Microvials (e.g., Agilent).
Centrifuge.
Block heater for hydrolysis.
Shaker.
Nitrogen evaporator.
GC–MS system (e.g., AutoSpec Ultima).
Helium 5.0.
Capillary column, 30 m × 0.25 mm × 0.25 µm Rtx 65.
HFIP (e.g., Aldrich, Poole, UK).
DIC (e.g., Aldrich).
3-Phenoxybenzoic acid (e.g., Aldrich)
2-Phenoxybenzoic acid (e.g., Aldrich) used as ISTD.
cis-3-(2,2-Dichlorovinyl)-2,2-dimethylcyclopropane carboxylic acid (e.g., Dr.
Ehrenstorfer).
Pyrethroids in Blood Plasma and Urine
23
16. trans-3-(2,2-Dichlorovinyl)-2,2-dimethylcyclopropane carboxylic acid (e.g., Dr.
Ehrenstorfer).
17. cis-3-(2,2-Dibromovinyl)-2,2-dimethylcyclopropane carboxylic acid (e.g., RousselUclaf, Romainville Cedex, France).
18. 4-Fluoro-3-phenoxybenzoic acid (e.g., Bayer Industry Services, Leverkusen, Germany).
19. cis-CDCA (e.g., Bayer Industry Services).
20. trans-CDCA (e.g., Bayer Industry Services).
21. Acetonitrile (Supra-Solv).
22. Tert.-Butyl-methylether (Supra-Solv).
23. Iso-octane (Supra-Solv).
24. For preparation of the standard solutions, about 10 mg of each compound (or proportionally more if purity < 100%) is weighed into separate 10-mL flasks. Each flask is diluted to
volume with acetonitrile. The concentration of these standard starting solutions is 1000
mg/L. The following dilutions are performed with these starting solutions:
a. For stock solution 1 of 10.0 mg/L, 100 µL of each standard starting solution is added
to a 10-mL flask, which is filled to volume with acetonitrile (1:100 dilution).
b. For stock solution 2 of 1.0 mg/L, 1000 µL of dilution 1 is added to a 10-mL flask,
which is filled to volume with acetonitrile (1:1000 dilution).
c. For stock solution 3 of 0.1 mg/L, 100 µL of dilution 1 is added to a 10-mL flask,
which is filled to volume with acetonitrile (1:10,000 dilution).
d. For stock solution 4 of 0.01 mg/L, 1000 µL of dilution 3 is added to a 10-mL flask,
which is filled to volume with acetonitrile (1:100,000 dilution).
e. For the ITSD solution of 1.0 mg/L, the preparation is done with separate dilutions as
for dilution 2 described in.
For the calibration experiment, defined volumes of dilution 1, 2, 3, or 4 are added to
2 mL urine. The dilutions for necessary concentrations are shown in Table 2.
3. Methods
3.1. Determination of Pyrethroids in Blood Plasma
3.1.1. Sample Preparation
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
Put the conditioned Oasis column on the SPE station.
Dilute 1 mL plasma with 1 mL ultrapure water in a test tube.
Add 10 µL of ITSD (e.g., Fenvalerat) (see Note 5).
Mix the sample slightly to get a homogeneous solution.
Trickle sample slowly on the Oasis column.
Let sample elute through the column under atmospheric pressure.
Rinse column with 2 mL ultrapure water.
Dry column 30 s under vacuum on the SPE station.
Dry column under nitrogen steam on the SPE station with drying option (approx 30 min)
at room temperature.
Rinse column with 2 mL n-hexane (see Note 6).
Elute pyrethroids with 3 mL hexane:dichloromethane 1:1 (v/v).
Evaporate solution in a nitrogen evaporator (e.g., Pierce) down to approx 200 µL.
Transfer sample in a microvial and narrow carefully with nitrogen down to dryness (see
Note 7).
Resolve sample in 25 µL toluene (analysis sample).
24
Leng and Gries
Table 2
Necessary Fortification Levels for Pyrethroid Metabolites (HFIP Method) in Urine
Concentration
(µg/L)
Stock solution
Spike volume (µL)
in 2 mL urine
Spike volume
ISTD dilution
1 mg/L (µL)
—
4
4
4
4
3
3
2
2
2
2
1
—
10
20
40
100
20
40
100
20
40
100
20
20
20
20
20
20
20
20
20
20
20
20
20
Blank value
0.05
0.1
0.2
0.5
1.0
2.0
5.0
10.0
20.0
50.0
100.0
3.1.2. Operational Parameters for GC and MS
3.1.2.1. GC PARAMETERS
Use HP 5890II with SSL-Injector and CTC A 200S Autosampler.
DB5 (30 m × 0.25 mm × 0.1 µm) column
He 80 kPa for 1 min, 5 kPa/min, 100-kPa gas pressure
1 min off purge time
40-mL/min split
3-mL/min septum purge
60°C 1 min > 15°C/min > 320°C > 10 min
300°C injection temperature (see Note 8)
1 µL injection volume
3.1.2.2. MS PARAMETERS
Use an Micromass AutoSpec Ultima.
250°C interface
200°C source
NCI mode inner source
Ammonia CI gas, 2 × 10-5 KPa source pressure (see Note 9)
0.5-mA filament
100 eV electron energy
Maximum 8000 accelerating voltage
350-V multiplier
10,000 resolution
Perfluorokerosin calibration gas
3.1.3. Analytical Determination
Inject into the GC–MS system 1 µL of the sample (see Subheading 3.1.1., step
14). If the instrument parameters are set as described in in selected ion monitoring
Pyrethroids in Blood Plasma and Urine
25
Table 3
SIM Masses and Retention Time for MS Detection of Pyrethroids
Pyrethroid
Bioallethrin
Permethrin (sum of 2 isomers)
Cyfluthrin (sum of 4 isomers)
Cypermethrin ( sum of 4 isomers)
Deltamethrin
Fenvalerat (ITSD)
Target mass (m/z)
Retention time (min)
167.107
206.998
206.998
206.998
296.895
211.053
10:45
14:13/14:18
14:36/14:45
14:48/14:58
15:55
15:25/15:34
(SIM) mode (Table 3), a stereoselective resolved chromatogram of each pyrethroid
can be obtained as shown in Fig. 4.
3.1.4. Method Validation
The calibration curve and the samples for precision control are prepared with plasma
of persons not exposed to pyrethroids. Necessary fortification levels for this procedure
are prepared in agreement with the fortification levels in Table 1. The linearity of all
pyrethroids is tested in a range between 5 and 1000 ng/L blood plasma, with correlation coefficients more than 0.995. If the method is working correctly, quality criteria
for precision in series can be achieved as shown in Table 4. The average recovery of
all compounds reached 90%.
3.1.5. Storage Stability
The starting solutions can be stored in a deep freezer at −18°C for at least 6 mo.
Longer times were not tested. We prefer fresh (monthly) preparation of stock solutions 2, 3, and 4. It was found that pyrethroids in plasma are not stable if they are
stored at +4°C (11). If analysis cannot start in about a day after blood plasma sampling, the plasma samples must be stored in a deep freezer at −70°C. Then, they are
stable for more than a year.
3.2. Determination of Pyrethrin/Pyrethroid Metabolites (cis/trans CDCA,
cis/trans-DCCA, cis-DBCA, FPBA, 3-PBA) in Urine
3.2.1. Sample Preparation
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
Transfer 2 mL urine in a screw cap test tube.
Add 20 µL ITSD solution (10 µg/L 2-PBA).
Add 500 µL concentrated hydrochloric acid.
Cover test tube with screw cap.
Hydrolyze sample for 2 h at 100°C in a block heater.
Add 3 mL tert.-butyl-methylether to the cold sample.
Cover test tube with screw cap and shake urine sample vigorously for 5 min.
Centrifuge sample for 5 min at 2000 .
Separate organic layer in a new screw cap test tube.
Add 2 mL tert.-butyl-methylether to sample.
Cover test tube with screw cap and shake urine sample vigorously for 5 min.
Centrifuge sample for 5 min at 2000 .
26
Leng and Gries
Fig. 4. High-resolution CI–MS chromatogram of pyrethroids in blood plasma separated on
a 30 m × 0.25 mm × 0.1 µm DB5 capillary column.
Pyrethroids in Blood Plasma and Urine
27
Table 4
Precision in Series and Detection Limits of Pyrethroids
Pyrethroid
Bioallethrin
Permethrin (sum of 2 isomers)
Cyfluthrin (sum of 4 isomers)
Cypermethrin (sum of 4 isomers)
Deltamethrin
Plasma 0.1
µg/L
R.S.D. (%)
Plasma 1.0
µg/L
R.S.D. (%)
Detection
limit
(ng/L)
10.5
8.4
9.9
6.4
15.1
17.5
16.9
9.4
10.8
10.3
5
5
5
5
20
RSD, relative standard deviation.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
Combine organic layer in the new screw cap test tube (step 9).
Discard the lower urine phase.
Dry organic layer under a gentle stream of nitrogen just to dryness.
Dissolve residue in 250 µL acetonitrile.
Add 30 µL of HFIP (see Note 10).
Add 20 µL of DIC.
Derivatize solution under slight mixing for 10 min at room temperature.
Add 1 mL 1 M sodium hydrogen carbonate solution.
Add 250 µL iso-octane.
Cover test tube and mix sample 10 min vigorously for extraction.
Centrifuge sample 5 min at 2000 for phase separation.
Separate iso-octane phase in a microvial.
3.2.2. Operational Parameters for GC and MS
3.2.2.1 GC PARAMETERS
Use HP 5890II with SSL-Injector and CTC A 200S Autosampler.
Rtx 65.30 m × 0.25 mm × 0.25 µm column
He 120 kPa for 1 min, 100 kPa/min, 80 kPa gas pressure
1 min off purge time
40-mL/min split
3-mL/min septum purge
60°C 1 min >8°C/min >150°C >30°C/min at 300°C for 20 min
300°C injection temperature
1 µL injection volume
3.2.2.2. MS Parameters
Use a Micromass AutoSpec Ultima.
250°C interface.
250°C source.
EI mode inner source (see Note 11).
0.3-mA filament.
70 eV electron energy.
Maximum 8000 accelerating voltage.
330-V multiplier.
28
Leng and Gries
Table 5
SIM Masses and Retention Time for MS Detection of Pyrethroid Metabolites
(HFIP-Ester) in Urine
Pyrethroid metabolite
cis -CDCA
trans-CDCA
cis-DCCA
trans-DCCA
cis-DBCA
2-PBA (internal standard)
3-PBA
FPBA
Target mass (m/z)
331.077
331.077
323.027
323.027
368.975
364.053
364.053
382.044
Retention time (min)
7:19
6:21
7:34
7:45
10:52
14:27
14:39
14:05
10,000 resolution.
Perfluorokerosine calibration gas
3.2.3. Analytical Determination
Inject 1 µL of the sample (sample preparation, step 24) into the GC–MS system. If
the instrument parameters are set as described in Subheading 3.2.2. in SIM EI+ mode
(Table 5), a stereoselective resolved chromatogram of each pyrethroid metabolite can
be obtained as shown in Fig. 5. This sample can optionally be analyzed in NCI mode
as shown in Fig. 6 (see Note 11).
3.2.4. Method Validation
The calibration curve and the samples for precision control are prepared with urine
of persons not exposed to pyrethroids. Necessary fortification levels for this procedure
were prepared in agreement with the fortification levels in Table 2. The linearity of all
pyrethroid metabolites is tested in a range between 0.1 and 100 µg/L urine, with correlation coefficients more than 0.995. If the method is working correctly, quality criteria
for precision in series can be achieved as listed in Table 6. The average recovery of all
compounds lies between 90 and 100%.
3.2.5. Storage Stability
The starting solutions and stock solutions can be stored in a deep freezer at −18°C
for at least 6 mo. Longer times were not tested. Urine samples can be stored for more
than a year at −21°C in a deep freezer
4. Notes
1. This method is developed for the determination of very low pyrethroid concentrations
in blood plasma, which are caused by the short pyrethroid half-lives in blood plasma.
Therefore, this method is useful for the determination of pyrethroids following acute
intoxication.
2. Several analytical techniques have been tested previously, but all gave poor reproducibilities or sensitivities. A direct extraction with iso-octane after precipitation with sodium
chloride and ethanol also works, but only for a few samples. In such a plasma extract,
Pyrethroids in Blood Plasma and Urine
29
Fig. 5. High-resolution EI+ MS chromatogram of pyrethroid metabolites in urine (as HFIP
esters) separated on a 30 m × 0.25 mm × 0.25 µm Rtx 65 capillary column.
30
Leng and Gries
Fig. 6. High-resolution CI–MS chromatogram of pyrethroid metabolites in urine (as HFIP
esters) separated on a 30 m × 0.25 mm × 0.25 µm Rtx 65 capillary column.
Pyrethroids in Blood Plasma and Urine
31
Table 6
Precision in Series and Detection Limits of Pyrethroid Metabolites (HFIP Ester) in Urine
Pyrethroid metabolite
Urine 1 µg/L
R.S.D. (%)
Urine 10.0 µg/L
R.S.D. (%)
Detection
limit (µg/L)
7.4
5.3
5.2
4.4
3.5
3.0
3.0
2.4
2.7
3.4
2.1
1.9
2.1
2.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
cis-CDCA
trans-CDCA
cis-DCCA
trans-DCCA
cis-DBCA
3-PBA
FPBA
RSD, relative standard deviation.
3.
4.
5.
6.
7.
8.
pyrethroids and blood plasma fats are extracted together. Then, if this sample is injected
into the GC, the blood plasma fat residues cannot be vaporized and build active residues
in the injector, which leads to memory effects and adsorption of pyrethroids. These problems can be solved with the described SPE.
In contrast to analytical methods covering only pyrethroid metabolites in urine, this
method has the advantage that it is possible to determine metabolites of synthetic pyrethroids (cis/trans-DCCA, cis-DBCA, 4-F-3-PBA, 3-PBA) as well as the metabolite of
pyrethrins/bioallethrin (cis/trans-CDCA) simultaneously. Another advantage is lower
cost because of shorter analysis time.
Several analytical techniques were tested previously, but the method chosen is the most
adequate. The esterification with methanol gave poor sensitivity for cis- and trans-CDCA
in the lower background level. Furthermore, it is impossible to separate the cis- and transCDCA–methylester on a DB5 capillary column. Esterification with ethanol enables a
separation between cis- and trans-CDCA–ethylester but also shows poor sensitivity in
the lower background level. Optimal sensitivity and selectivity are only found with HFIP
as an excellent esterification reagent for all tested substances within a quantification level
of 0.1 µg/L.
The spiked ISTD fenvalerat cannot compensate all different properties of the pyrethroids
during the analysis and GC–MS determination. In this method, fenvalerat is used as the
ISTD because this pyrethroid is not often used in Germany. Otherwise, it might be useful
to work with deuterated or 13C-labeled internal pyrethroid standards if they are available.
The washing step with n-hexane eliminates the fat residues, and the elution with hexane/
dichloromethane (1:1 v/v) is done to get nearly matrix-free extracts.
The extract of the Oasis cartridges must be evaporated very carefully to dryness because
pyrethroids with lower boiling points evaporate with nitrogen if the nitrogen steam is too
high or the evaporating process is not stopped immediately after sample drying. If no fine
adjustable nitrogen evaporator is available, this drying step can also be done in a vacuum
centrifuge. In this case, 100 µL toluene should be added to the extract before the solvent
evaporation process is started. Toluene works as a keeper and minimizes loss of pyrethroids during this step. After sample evaporation to approx 25 µL, this residue can be
used for GC–MS analysis.
A high temperature of the GC injector is used for optimal evaporation of pyrethroids and
reduction of possible memory effects based on injector temperature distribution, which
can occur by condensation at cold places in the injector. Therefore, it is advantageous to
32
Leng and Gries
use deactivated double-gooseneck injector liners. Matrix residues of samples in injector
liners or at the first centimeters of a capillary column can result in lower detection limits,
especially for deltamethrin. Deltamethrin is critical to analyze because it shows the lowest response of all pyrethroids based on its unfavorable fragmentation pattern. A possible
contamination source is the autosampler syringe itself because residues of pyrethroids are
not washed out quantitatively when nonpolar cleaning solvent is used. The best cleaning
procedure is a two-step washing process with different polar solvents (e.g., toluene and
dichloromethane).
9. Ammonia is described in this method as an NCI reactant gas, but analogous results can be
obtained with methane. Notice that not all GC–MS instruments and pumps are equipped
for ammonia. If no high-resolution GC–MS system is available, the analyses of pyrethroids can also be done on other GC–MS systems. The only disadvantage is a detection
limit that is about a factor of 10 higher.
10. The derivatization with HFIP works only in water-free samples. Therefore, it is important
to separate tert.-butyl methylether (t-BME) carefully from the lower water phase. HFIP is
a very powerful reagent that reacts spontaneously with carboxylic acids; DIC is used as a
catalyzor and water binder (Fig. 3).
11. This routine method was developed for analysis in a high-resolution GC–MS system in
EI + mode and optional CI – mode. The installation of electronegative fluorine via
derivatization with HFIP also enables a very sensitive determination in CI– mode (Fig. 6).
By CI– mode detection, limits in the lower nanogram-per-liter range are possible (13).
The advantage of high mass resolution (10,000) in both detection techniques enables the
accuracy of analytical results. EI+ mode is used for routine analysis because it is more
stable in comparison to CI–, which is used for verification. The stability or reproducibility
in CI– depends on higher influences of sample matrix to the fragmentation process, which
is weaker in CI– than in EI+ mode. This problem can be solved with deuterated or 13Clabeled ITSDs. A determination with low mass resolution mass spectrometers was not
tested, but is known to work. Possible matrix interferences that occur on these instruments can be solved with longer columns or hydrogen as carrier gas (use caution). Of
course, this leads to longer analysis time combined with higher costs.
References
1. Aldridge, W. N. (1990) An assessment of the toxicological properties of pyrethroids and
their neurotoxicity. Crit. Rev. Toxicol. 21, 89–104.
2. Eadsforth, C. V., Bragt, P. C., and van Sittert, N. J. (1988) Human dose-excretion studies
with pyrethroid insecticides cypermethrin and alphacypermethrin: relevance for biological monitoring. Xenobiotica 18, 603–614.
3. Woollen, B. H., Marsh, J. R., Laird, W. J. D., and Lesser, J. E. (1992) The metabolism of
cypermethrin in man: differences in urinary metabolite profiles following oral and dermal
administration. Xenobiotica 22, 983–991.
4. Leng, G., Leng, A., Kühn, K.-H., Lewalter, J., and Pauluhn, J. (1997) Human dose excretion studies with the pyrethroid insecticide cyfluthrin: urinary metabolite profile following inhalation. Xenobiotica 27, 1272–1283.
5. Class, T. J., Ando, T., and Casida, J. E. (1990) Pyrethroid metabolism: microsomal oxidase metabolites of (S)-bioallethrin and the six natural pyrethrins. J. Agric. Food Chem.
38, 529–537.
6. Leng, G., Kuehn, K.-H., Wieseler, B., and Idel, H. (1999) Metabolism of (S)-bioallethrin
and related compounds in humans. Toxicol. Lett. 107, 109–121.
Pyrethroids in Blood Plasma and Urine
33
7. He, F., Sun, S., Han, K., et al. (1988) Effects of pyrethroid insecticides on subjects engaged in packaging pyrethroids. Br. J. Industr. Med. 45, 548–551.
8. He, F., Wang, S., Liu, L., Chen, S., Zhang, Z., and Sun, J. (1989) Clinical manifestations
of acute pyrethroid poisoning. Arch. Toxicol. 63, 54–58.
9. Leng, G. and Lewalter, J. (1999) Role of individual susceptibility in risk assessment of
pesticides. Occup. Environ. Med. 56, 449–453.
10. Leng, G., Kuehn, K.-H., and Idel, H. (1996) Biological monitoring of pyrethroid metabolites in urine of pest control operators. Toxicol. Lett. 88, 215–220.
11. Leng, G., Kühn, K.-H., and Idel, H. (1997) Biological monitoring of pyrethroids in blood
plasma and pyrethroid metabolites in urine: applications and limitations. Sci. Tot. Environ.
199, 173–181.
12. Leng, G., Ranft, U., Sugiri, D., Hadnagy, W., Berger-Preiss, E., and Idel, H. (2003) Pyrethroids used indoor—biological monitoring of exposure to pyrethroids following an indoor pest control operation. Int. J. Hyg. Env. Health 206, 85–92.
13. Leng, G., Kuehn, K.-H., Leng, A., Gries, W., Lewalter, J., and Idel, H. (1997) Determination of trace levels of pyrethroid metabolites in human urine by capillary gas chromatography–high resolution mass spectrometry with negative chemical ionization.
Chromatographia 46, 265–274.
14. Kühn, K.-H., Leng, G., Bucholski, K. A., Dunemann, L., and Idel, H. (1996) Determination of pyrethroid metabolites in human urine by capillary gas chromatography–mass spectrometry. Chromatographia 43, 285–292.
15. Berger-Preiß, E., Levsen, K., Leng, G., Idel, H., Sugiri, D., and Ranft, U. (2002) Indoor
pyrethroid exposure in homes with woollen textile floor coverings. Intl. J. Hyg. Env. Med.
205, 459–472.
16. Heudorf, U. and Angerer, J. (2001) Metabolites of pyrethroid insecticides in urine specimens: current exposure in an urban population in Germany. Environ. Health Persp. 109,
213–217.
Pesticides in Human Serum/Plasma
35
3
A Multianalyte Method for the Quantification
of Current-Use Pesticides in Human Serum or Plasma
Using Isotope Dilution Gas Chromatography–
High-Resolution Mass Spectrometry
Dana B. Barr, Roberto Bravo, John R. Barr, and Larry L. Needham
Summary
We propose a sensitive and accurate analytical method for quantifying 29 current-use
pesticides in human serum or plasma. These pesticides include organophosphates, carbamates, chloroacetanilides, and synthetic pyrethroids, pesticides used in both agricultural and residential settings. Our method employs simple solid-phase extraction
followed by highly selective analysis using isotope dilution gas chromatography–highresolution mass spectrometry. The method is very accurate, has limits of detection
(LODs) in the low picogram/gram range, and has coefficients of variation that are typically less than 20% at the low picogram/gram end of the method linear range.
Key Words: Contemporary; gas chromatography; human; isotope dilution; mass
spectrometry; pesticides; plasma; serum.
1. Introduction
Exposure assessment is an integral component of risk assessment of pesticides, but
often reliable exposure assessment information lacks quantity or quality. Because
human exposure to pesticides is multimedia and multiroute and varies with the use of
pesticides, environmental monitoring of exposure must account for the concentration
of the pesticide in all media, the time in contact with each medium, and route(s) of
exposure to calculate aggregate exposure information to a given pesticide accurately
(1). Even when all of this information is considered, measurements of the external
dose may not accurately reflect the absorbed, or internal, dose.
Because of their inherent chemical nature, current-use pesticides have short biological half-lives, usually a few hours or days (2–7). Therefore, current-use pesticides
are taken up rapidly into the bloodstream, metabolized, and eliminated from the body
in the urine as polar metabolites, which are often conjugated as glucuronides or sulfates.
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
35
36
Barr et al.
Because the metabolites of pesticides are usually excreted in urine soon after exposure and because urine is usually a plentiful matrix and easy to obtain, biological monitoring of exposure to current-use pesticides has typically involved quantifying
pesticide metabolites in urine (3). In addition, concentrations of pesticides or their
metabolites in urine are typically much higher than in blood and are detectable for a
longer period of time (e.g., a few days as compared to several hours in blood). However, this approach is not without its limitations. Individual urinary metabolites can
often be derived from multiple pesticides or even from exposure to the metabolite
itself as an environmental degradate. Furthermore, urine volume and dilution vary
among “spot” samples; thus, it may be difficult to compare concentrations among
samples even when adjusting for the dilution. For most current-use pesticides, creatinine adjustment is the most common method for dilution adjustment; however, creatinine concentrations vary with demographics, so this approach loses its appeal when
applied to a diverse population. Another limitation, from a practical standpoint, in
measuring urinary metabolites is that authentic standards are often not commercially
available because many metabolites are newly identified.
Measuring pesticides in blood has several advantages over measuring pesticide
metabolites in urine. Because the parent chemical is measured, detailed metabolism
information (i.e., which metabolites are formed) is not required. Also, the measurement of the intact pesticide in blood instead of a metabolite provides more specificity
for the exposure. For example, 3,5,6-trichloropyridinol (3,5,6-TCPy) in urine would
reflect exposure to chlorpyrifos, chlorpyrifos-methyl, or environmental degradates
(e.g., TCPy itself or pesticide oxons). We cannot distinguish between these exposures
with urinary TCPy. However, if these chemicals are measured in blood, we can differentiate the exposures. For example, a detectable level of chlorpyrifos in blood would
unequivocally identify an exposure to chlorpyrifos. Distinguishing between exposure
to each pesticide and exposure to their respective degradation products is very important in risk assessment because the toxicities, and hence the acceptable daily intake,
for chlorpyrifos, chlorpyrifos-methyl, the oxons, and 3,5,6-TCPy all differ.
Because blood is a regulated fluid (i.e., the volume does not vary substantially with
water intake or other factors), the blood concentrations of toxicants measured at a
specified time interval after exposure will be the same as long as the absorbed amounts
are constant; thus, no corrections for dilution are necessary. Furthermore, blood measurements are more likely than urine measurements to reflect the dose available for the
target site (8) because the measured dose has not yet been eliminated from the body.
The major disadvantages of blood measurements are the venipuncture required to
obtain the sample and the low toxicant concentrations. Blood collection is more costly,
and the invasive sampling often limits study participation, especially for children. In
addition, when samples can be obtained, the amount of blood available to perform the
analysis is often limited; therefore, highly sensitive analytical techniques may be required. Analysis of blood is further complicated by the inherently low toxicant concentrations, often three orders of magnitude lower than urinary metabolite levels.
For most researchers, the disadvantages of blood measurements have far outweighed the advantages. In fact, most of the scientific literature detailing biological
monitoring of current-use pesticides describes urinary measurements (9). However,
Pesticides in Human Serum/Plasma
37
several methods involving blood, serum, or plasma measurements of a variety of contemporary pesticides have been published (10–35). The pesticides measured using
these methods include primarily organophosphate and carbamate insecticides. The
majority of these methods were developed for forensic applications or for diagnosis of
acute pesticide intoxication and have LOD ranges in the high nanograms per milliliter
to micrograms per milliliter. In all cases, these methods lack the sensitivity or the
selectivity to measure pesticides in blood or blood products resulting from low-level
exposures.
We have developed a sensitive and accurate method for quantifying 29 contemporary pesticides in human serum or plasma (Table 1). Our method uses a simple solidphase extraction (SPE) followed by a highly selective analysis using isotope dilution
gas chromatography–high-resolution mass spectrometry (GC–HRMS).
2. Materials
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
Standards of the pesticides and labeled pesticides (Table 2) with purity higher than 99%.
Ammonium sulfate.
Anhydrous sodium sulfate.
Oasis® HLB™ SPE columns (Waters, Milford, MA).
Disposable empty sorbent cartridges.
SPE extraction manifold.
Pesticide quality solvents: dichloromethane, methanol, and toluene.
Bioanalytical grade I water.
SuporCap-100 filtration capsule.
Volumetric flasks.
Automatic pipets with disposable tips.
15-mL glass centrifuge tubes.
1-mL conical autosampler vials (silanized) with crimp tops.
Qorpak glass bottles with Teflon caps (30 mL).
TurboVap LV.
MAT900 magnetic sector mass spectrometer (ThermoFinnigan, Bremen, Germany).
GC (e.g., Agilent 6980, Palo Alto, CA) equipped with autosampler (e.g., CTC A200S)
and operated using XCalibur® software
18. DB5 MS column ([14% cyanopropylphenyl]-methyl polysiloxane, 30 m, 0.25-mm id, 25µm film) (e.g., J & W Folsom, CA).
19. Helium (>99.999%).
3. Methods (36)
3.1. Standards
3.1.1. Native Standards
1. Prepare individual stock solutions by dissolving 3 mg of each standard into 15 mL toluene and mixing well to obtain a concentration of 200 ng/µL.
2. Divide into 1-mL aliquots, flame seal in ampules, and store at −20°C until used.
3.1.2. Internal Standards
1. Prepare stock internal standard solutions by dissolving 5 mg of each stable isotope labeled
standard into 50 mL toluene and mixing well (see Note 1).
2. An internal standard spiking solution is prepared by diluting 1 mL of each stock solution
Analyte
Parent pesticide
38
Table 1
Pesticides Included in the Multianalyte Method
Class
38
Acetochlor
Alachlor
Atrazine
Bendiocarb
Carbofuran
Carbofuran, carbosulfan
Chlorothalonil
Chlorpyrifos
Chlorthal-dimethyl
Diazinon
Dichlorvos
Dicloran
Diethyltoluamide (DEET)
Fonophos
Propoxur
Malathion
Metalaxyl
Methyl parathion
Metolachlor
Carbaryl, naphthalene
Parathion
cis-Permethrin
trans-Permethrin
Phorate
Parathion
cis-Permethrin
trans-Permethrin
Phorate
Chloroacetanilide
Chloroacetanilide
Triazine
Carbamate
Carbamate
Carbamate
Miscellaneous
Organophosphate
Chloroterephthalate
Organophosphate
Organophosphate
Chloronitroaniline
Toluamide
Organophosphate
Carbamate
Organophosphate
Phenylamide
Organophosphate
Cloroacetanilide
Carbamate, polycyclic
aromatic hydrocarbon
Organophosphate
Synthetic pyrethroid
Synthetic pyrethroid
Organophosphate
Phthalimide
Propoxur
Terbufos
Tetrahydrophthalimide
Trifluralin
Folpet
Propoxur
Terbufos
Captan, captafol
Trifluralin
N-Trihalomethylthio
Carbamate
Organophosphate
N-Trihalomethylthio
Dinitroaniline
Herbicide
Herbicide
Herbicide
Insecticide
Insecticide, nematocide
Insecticide, nematocide
Fungicide
Insecticide
Herbicide
Insecticide, acaricide
Insecticide, acaricide
Fungicide
Repellant
Insecticide
Insecticide
Insecticide, acaricide
Fungicide
Insecticide, acaricide
Herbicide
Insecticide, plant growth
regulator
Insecticide, acaricide
Insecticide
Insecticide
Insecticide, acaricide,
nematocide
Fungicide
Insecticide
Insecticide, nematocide
Fungicide
Herbicide
Barr et al.
Acetochlor
Alachlor
Atrazine
Bendiocarb
Carbofuran
Carbofuranphenol
Chlorothalonil
Chlorpyrifos
Chlorthal-dimethyl
Diazinon
Dichlorvos
Dicloran
Diethyltoluamide (DEET)
Fonophos
2-Isopropoxyphenol
Malathion
Metalaxyl
Methyl parathion
Metolachlor
1-Naphthol
Use
Pesticides in Human Serum/Plasma
39
Table 2
Pesticides and Their Labeled Standards
Pesticide
Labeled pesticide
2-Isopropoxyphenol (IPP)
Dichlorvos (DCV)
Carbofuranphenol (CFP)
Phthalimide (PI)
Tetrahydrophthalimide (THPI)
Diethyltoluamide (DEET)
1-Naphthol (1N)
Trifluralin (TFL)
Propoxur (PPX)
Phorate (PHT)
Bendiocarb (BCB)
Terbufos (TBF)
Diazinon (DZN)
Fonophos (FFS)
Carbofuran (CF)
Atrazine (ATZ)
Dicloran (DCN)
Acetochlor (ACC)
Alachlor (ALC)
Chlorothalonil (CTNL)
Metalaxyl (MXL)
Chlorpyrifos (CPF)
Methyl parathion (MP)
Chlorthal-dimethyl (DCL)
Metolachlor (MTCL)
Malathion (MLTN)
Parathion (PTN)
cis-Permethrin (CPM)
trans-Permethrin (TPM)
2-Isopropoxyphenol (IPP)
Dimethyl-D6-DCV
Ring-13C6-CFP
Ring/carboxyl-13C4-PI
Ring-D6-THPI
Dimethyl-D6-DEET
Ring-13C6-1N
Dipropyl-D9-TFL
Diethoxy-13C4-PHT
Diethoxy-13C4-TBF
Diethyl-D10-DZN
Ring-13C6-FFS
Ring-13C6-CF
Ethylamine-D5-ATZ
Ring-13C6-DCN
Ring-13C6-ACC
Ring-13C6-ALC
Propionyl-D4-MXL
Diethyl-D10-CPF
Dimethyl-D6-DCL
Ring-13C6-MTCL
D10-MLTN
Diethyl-D10-PTN
Phenoxy-13C6-CPM
Phenoxy-13C6-TPM
(including the ones purchased in methanol and nonane) with acetonitrile in a 100-mL
volumetric flask to obtain a concentration of 10 pg/µL.
3. Divide into 1-mL aliquots, flame seal in ampules, and store at −20°C until used.
3.1.3. Calibration Standards
1. Create 10 working standard sets (0.25, 0.5, 2, 5, 10, 20, 50, 100, 200, and 400 pg/µL)
from the native standards to encompass the entire linear range of the method. The internal
standard concentration should be kept constant at 100 pg/µL.
2. Divide into 1-mL aliquots, flame seal in ampules, and store at −20°C until used.
3.2. Quality Control Materials
1. Pool serum samples from multiple donors (see Note 2) and mix well.
2. Pressure filter to 0.2 µm to remove large particles.
3. Split serum into three pools of equal volume.
40
Barr et al.
4.
5.
6.
7.
8.
9.
Spike the first pool to a concentration of 15 pg/g.
Spike the second pool to a concentration of 50 pg/g.
Leave the last pool unspiked.
Mix for 24 h under refrigeration.
Divide into 4-mL aliquots. Cap, label, and store the vials at −20°C until used.
Determine the mean concentration and the analytic variance by the repeat measurement
of at least 20 samples in different analytical runs.
10. Evaluate quality control (QC) acceptance based on the Westgard multirules (37).
3.3. Laboratory Reagent Blanks
1. Pipet 4 mL bioanalytical grade I water into centrifuge tube (see Note 3).
2. Prepare as if an unknown sample as indicated vide infra in Subheading 3.4. (see Note 4).
3. Concentrations of the pesticides in the blank samples are required to be less than the LOD
for the run to be considered acceptable.
3.4. Sample Preparation
1. Bring all samples, QCs, reagents, and standards to room temperature.
2. Weigh a 4-g aliquot of serum/plasma into a test tube.
3. Spike samples with 100 µL of the internal standard, mix, and allow to equilibrate for
approx 5 min.
4. Denatured serum proteins were denatured with 4 mL saturated ammonium sulfate
(see Note 5).
5. Centrifuge samples at 2140g for 5 min.
6. Meanwhile, precondition Oasis SPE columns with 2 mL methanol followed by 2 mL water.
7. Pass the supernatants from the serum samples through the SPE columns and discard.
8. Dry columns using 20 psi vacuum for 20 min.
9. Elute SPE cartridges with 4 mL dichloromethane.
10. Load empty disposable cartridges with 1 g anhydrous sodium sulfate.
11. Pass eluates through sodium sulfate cartridges and collect (see Note 6).
12. Concentrate extracts to about 500 µL using a TurboVap evaporator set at 37°C and 15 psi
head pressure of nitrogen.
13. Transfer concentrated extracts to a 1-mL conical vial.
14. Add 10 µL toluene to each vial as a keeper agent.
15. Allow to evaporate to approx 10 µL at ambient temperature.
16. Cap vials and store under refrigeration until analyzed.
3.5. Instrumental Analysis
1. Perform analyses using a gas chromatograph (split/splitless injector) interfaced to a mass
spectrometer equipped with an autosampler and operated using software.
2. Install the capillary column into the gas chromatograph.
3. Set helium carrier gas at a linear velocity of 35 cm/s.
4. Set the injector and transfer line temperatures at 240 and 270°C, respectively.
5. Establish a GC program as follows: 100ºC initial column temperature, hold for 1 min,
increase to 180°C at 15°C/min, hold for 2 min, increase to 221°C at 3°C/min, then finally
increase to 280°C at 25°C/min and hold for 5 min.
6. Set up MS acquisition program as follows: selected ion monitoring (SIM) mode; 5000 K
initial accelerating voltage; resolution 10,000 as defined at 10% valley; perfluorokerosene
(PFK) ions used as lock and calibration masses. The monoisotopic masses for each ion
Pesticides in Human Serum/Plasma
41
monitored for the pesticides and their respective internal standards, the ion types (i.e.,
fragment or molecular ion), ion composition, retention windows for analysis, and relative
retention times are shown in Table 3 (see Notes 7 and 8).
7. Inject 2 µL of each extract using a splitless injection.
3.6. Data Processing and Analysis
1. Set the detection and baseline thresholds to 40 and 4, respectively, and the minimum peak
width to 1. In addition, set up processing to subtract the background signal and smooth all
data (three-point smooth).
2. Process data automatically using XCalibur® software supplied with the mass spectrometer.
3. Double check peak selection and integration.
4. Download analysis data into a permanent storage database.
3.7. Method Validation
1. LOD. Calculate the analytical LOD for the method as 3s0, where s0 can be estimated as
the y-intercept of a linear regression analysis of a plot of the standard deviation vs the
concentration (30) (Table 4).
2. Extraction recovery. Calculate extraction recovery by spiking six 4-mL blank serum
samples (see Subheading 3.2.) with pesticide standards to a final concentration of 32 pg/
g. Prepare these samples simultaneously with six 4-mL unspiked samples (see Subheading 3.4.). After extraction, spike the extracts from the unspiked samples with the same
amount of native pesticides as the samples spiked before extraction. Add internal standard (100 µL) to each extract. Analyze as indicated in Subheading 3.5. Calculate the
recoveries as the ratios of spiked samples to the control samples.
3. Relative recovery. Determine the method of relative recovery by spiking blank serum
samples (see Subheading 3.2.) with a known amount of the pesticides. Prepare and analyze samples according to the method (see Subheadings 3.4. and 3.5.). Compare the
calculated and the spike concentrations by linear regression analysis of a plot of the calculated concentrations vs the expected concentrations. With this analysis, a slope of 1.0
would be indicative of 100% relative recovery.
4. Notes
1. Exceptions to this stock preparation are carbofuran, alachlor, metolachlor, and
chlorpyrifos, which are purchased as 100 µg/mL solutions in methanol or nonane.
2. We purchased expired serum from the Red Cross in Cincinnati, Ohio.
3. Because virtually all serum samples tested had detectable levels of at least one of the
pesticides or metabolites of interest, water was used as a laboratory reagent blank. The
blank contained the same water used in the daily preparation of reagents. They are used to
ensure that contamination does not occur at any step in the preparation process.
4. Unknown serum or plasma samples, QC materials, and laboratory reagent blanks are prepared identically.
5. Acids cannot be used for denaturation because they degrade many of the compounds of
interest.
6. To evaporate samples fully and extend life of the column, all residual water must be
carefully removed. This step is essential.
7. If no labeled standard is available for a particular pesticide, the nearest labeled standard
in the same retention time window can be used as an internal standard.
8. The total analysis time per sample is about 30 min.
Analyte
42
Monoisotopic
mass
Ion composition
Retention window
Relative
retention time
1.00
1.00
1.20
1.19
1.26
1.26
1.90
1.90
2.01
1.99
2.03
2.02
2.10
2.10
n/a
n/a
2.27
2.24
2.30
2.32
2.32
2.47
n/a
n/a
2.61
12.61
(continued)
M
M + 13C6
F
F + D6
M
M + 13C6
M
M + 13C4
M
152.0837
158.1039
184.9771
191.0147
164.0837
170.1039
147.0320
151.0454
151.0633
C4H7ClO4P
C4D6HClO4P
C10H12O2
13C 12C H O
6
4 12 2
C8H5NO2
13C 12C H NO
4
4 5
2
8H9NO2
1
1
1
1
1
1
1
1
1
M + D6
M
M + D6
M
M + 13C6
L
C
F
F + D3
F
M
M + 13C4
F
L
C
M
M + 13C4
157.1010
190.1232
196.1608
144.0575
150.0776
130.9920
180.9888
264.0232
267.0420
152.0837
260.0128
264.0262
166.0630
168.9888
268.9824
288.0441
292.0576
C8D6H3NO2
C12H16NO
C12D6H10NO
C10H7OH
13C 12C H OH
6
4 7
n/a
n/a
C 8H5N3 O4F3
C8D3H2 N3O4F3 2
C9H12O2
C7H17O2PS3
13C 12C H O PS
4
3 17 2
3
C9H10O3
n/a
n/a
C9H21O2PS3
13C 12C H O PS
4
5 21 2
3
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
3
3
C9H12O2
13C 12C H O
6
3 12 2
Barr et al.
2-Isopropoxyphenol (IPP)
Ring-13C6-2-IPPl
Dichlorvos (DCV)
Dimethyl-D6-DCV
Carbofuranphenol (CFP)
Ring-13C6-CFP
Phthalimide (PI)
Ring/carboxyl-13C4-PI
Tetrahydrophthalimide
(THPI)
Ring-D6-THPI
DEET
Dimethyl-D6-DEET
1-Naphthol (1N)
Ring-13C6-1N
PFK
PFK
Trifluralin (TFL)
Dipropyl-D9-TFL
Propoxur (PPX)
Phorate (PHT)
Diethoxy-13C4-PHT
Bendiocarb (BCB)
PFK
PFK
Terbufos (TBF)
Diethoxy-13C4-TBF
Ion type
42
Table 3
High-Resolution Mass Spectral Analysis Specifications
M
M + D10
M
M + 13C6
L
C
F
F + 13C6
F
F + D5
M+2
M + 13C6 + 2
F
F + 13C6
F
F + 13C6
M+2
L
C
F
F + D4
F
F + D10
M
F+2
304.1011
314.1638
246.0302
252.0503
230.9856
292.9824
164.0837
170.1039
200.0703
205.1017
207.9620
213.9822
223.0764
229.0965
188.1075
194.1227
265.8786
168.9888
230.9856
206.1181
210.1432
313.9574
324.0202
263.0017
300.8807
C12H21N2O3PS 3
C12D10H11N2O3PS
C10H15OPS2
13C 12C H OPS 3
6
4 15
2
n/a
n/a
C10H12O2
13C 12C H O
6
4 12 2
C7H11ClN5
C7D5H6ClN5
C6H4N2O235Cl37Cl
13C H N O 35Cl37Cl
6 4 2 2
C12H14NO2Cl
13C 12C H NO Cl
6
6 14
2
C12H14NO
13C 12C H NO 4
6
6 14
C835Cl37Cl N2
n/a
n/a
C12H16O2N
C12D4H12O2N
C9H11Cl2NO3PS 5
C9D10HCl2NO3PS
C8H10NO5PS
C9H30335Cl337Cl 5
2
3
3
2
3
3
4
4
4
4
4
4
4
4
4
4
4
4
4
5
5
3
5
5
5
2.65
2.62
2.71
2.71
n/a
n/a
2.84
2.84
2.84
2.83
2.89
2.89
3.30
3.30
3.41
3.41
3.46
n/a
n/a
3.59
3.58
3.62
3.58
3.66
3.72
(continued)
Pesticides in Human Serum/Plasma
43
Diazinon (DZN)
Diethyl-D10-DZN
Fonophos (FFS)
Ring-13C6-FFS
PFK
PFK
Carbofuran (CF)
Ring-13C6-CF
Atrazine (ATZ)
Ethylamine-D5-ATZ
Dicloran (DCN)
Ring-13C6-DCN
Acetochlor (ACC)
Ring-13C6-ACC
Alachlor (ALC)
Ring-13C6-ALC
Chlorothalonil (CTNL)
PFK
PFK
Metalaxyl (MXL)
Propionyl-D4-MXL
Chlorpyrifos (CPF)
Diethyl-D10-CPF
Methyl parathion (MP)
Chlorthal-dimethyl (DCL)
43
44
Table 3
High-Resolution Mass Spectral Analysis Specifications (continued)
Analyte
44
Dimethyl-D6-DCL
Metolachlor (MTCL)
Ring-13C6-MTCL
Malathion (MLTN)
D10-MLTN
Parathion (PTN)
Diethyl-D10-PTN
PFK
PFK
cis-Permethrin (CPM)
Phenoxy-13C6-CPM
trans-Permethrin (TPM)
Phenoxy-13C6-TPM
PFK
PFK
Ion type
F + D3 + 2
F
F + 13C6
F
F + D5
M
M + D10
L
C
F
F+13C6
F
F+13C6
L
C
Monoisotopic
mass
Ion composition
Retention window
Relative
retention time
303.8995
238.0999
244.1200
255.9993
261.0307
291.0330
301.0958
230.9856
292.9824
183.0810
189.1011
183.0810
189.1011
180.9888
192.9888
C9D30335Cl337Cl
C13H17ClNO
13C 12C H ClNO
6
7 17
C7H13O4PS2
C7D5H8O4PS2
C10H14NO5PS
C10D10H4NO5PS
n/a
n/a
C13H11O
13C 12C H O
6
7 11
C13H11O
13C 12C H O
6
7 11
n/a
n/a
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
3.70
3.77
3.77
3.85
3.81
4.08
4.04
n/a
n/a
5.63
5.63
5.70
5.70
n/a
n/a
C, calibration mass; F, fragment ion; L, lock mass; M, molecular ion; n/a, not applicable; PFK, perfluorokerosine.
Barr et al.
Pesticides in Human Serum/Plasma
45
Table 4
Method Specifications
Analyte
LOD
(pg/g)
Extraction
Recovery
%
(N = 6)
2-Isopropoxyphenol
Dichlorvos
Carbofuranphenol
Phthalimide
Tetrahydrophthalimide
Deet
1-Naphthol
Trifluralin
Propoxur
Phorate
Bendiocarb
Terbufos
Diazinon
Fonophos
Carbofuran
Atrazine
Dicloran
Acetochlor
Alachlor
Chlorothalonil
Metalaxyl
Chlorpyrifos
Methyl parathion
Chlorthal-dimethyl
Metolachlor
Malathion
Parathion
cis-Permethrin
trans-Permethrin
3
1
1
20
1
10
20
1
1
1
5
1
0.5
1
1
1
1
1
1
5
5
1
2
1
1
12
1
1
1
48 ± 15
15 ± 10
80 ± 8
89 ± 6
91 ± 8
43 ± 4
12 ± 10
15 ± 8
61 ± 12
21 ± 11
46 ± 6
17 ± 9
27 ± 5
20 ± 8
38 ± 10
53 ± 12
46 ± 23
23 ± 8
21 ± 11
14 ± 12
55 ± 9
21 ± 14
20 ± 16
18 ± 5
23 ± 9
22 ± 18
20 ± 18
13 ± 5
14 ± 5
Relative
Recovery
%
(N = 20)
RSD
(N = 6)
100 ± 3
101 ± 4
100 ± 3
98 ± 2
99 ± 5
101 ± 2
101 ± 4
98 ± 3
99 ± 4
99 ± 4
99 ± 8
97 ± 6
101 ± 5
103 ± 6
98 ± 3
101 ± 3
100 ±3
95 ± 4
100 ± 4
101 ± 3
100 ± 4
96 ± 5
100 ± 6
101 ± 3
101 ± 3
104 ± 8
101 ± 7
98 ± 7
100 ± 8
17
13
8
25
14
10
24
27
19
13
20
17
19
14
30
17
13
13
14
14
25
16
20
14
11
20
17
31
28
LOD, limit of detection; RSD, relative standard deviation determined from spiked serum
samples.
References
1. Donaldson, D., Kiely, T., and Grube, A. (2002) 1998 And 1999 Market Estimates. Pesticides Industry Sales and Usage Report. U.S. Environmental Protection Agency, Washington, DC.
2. Garfitt, S. J., Jones, K., Mason, H. J., and Cocker, J. (2002) Exposure to the organophosphate diazinon: data from a human volunteer study with oral and dermal doses. Toxicol
Lett. 134, 105–113.
3. Barr, D. B., Barr, J. R., Driskell, W. J., et al. (1999) Strategies for biological monitoring of
exposure for contemporary-use pesticides. Toxicol. Ind. Health 15, 168–179.
46
Barr et al.
4. Griffin, P., Mason, H., Heywood, K., and Cocker, J. (1999) Oral and dermal absorption of
chlorpyrifos: a human volunteer study. Occup. Environ. Med. 56, 10–13.
5. Leng, G., Kuhn, K. H., and Idel, H. (1997) Biological monitoring of pyrethroids in blood
and pyrethroid metabolites in urine: applications and limitations. Sci. Total Environ. 199,
173–181.
6. Leng, G., Leng, A., Kuhn, K. H., Lewalter, J., and Pauluhn, J. (1997) Human dose–excretion studies with the pyrethroid insecticide cyfluthrin: urinary metabolite profile following inhalation. Xenobiotica 27, 1273–1283.
7. Nolan, R. J., Rick, D. L., Freshour, N. L., and Saunders, J. H. (1984) Chlorpyrifos: pharmacokinetics in human volunteers. Toxicol. Appl. Pharmacol. 73, 8–15.
8. Needham, L. L., Ashley, D. L., and Patterson, D. G., Jr. (1995) Case studies of the use of
biomarkers to assess exposures. Toxicol. Lett. 82–83, 373–378.
9. Barr, D. and Needham, L. (2002) Analytical methods for biological monitoring of exposure to pesticides: a review. J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 778, 5.
10. Stein, V. B. and Pittman, K. A. (1976) Gas–liquid chromatographic determination of
azinphos ethyl in human plasma and in mouse plasma, tissue, and fat. J. Assoc. Off. Anal.
Chem. 59, 1094–1096.
11. Fournier, E., Sonnier, M., and Dally, S. (1978) Detection and assay of organophosphate
pesticides in human blood by gas chromatography. Clin. Toxicol. 12, 457–462.
12. Nordgren, I., Bengtsson, E., Holmstedt, B., and Pettersson, B. M. (1981) Levels of
metrifonate and dichlorvos in plasma and erythrocytes during treatment of schistosomiasis with bilarcil. Acta Pharmacol. Toxicol. (Copenh.) 49(Suppl. 5), 79–86.
13. Michalke, P. (1984) Determination of p-nitrophenol in serum and urine by enzymatic and
non-enzymatic conjugate hydrolysis and HPLC. Application after parathion intoxication.
Z. Rechtsmed. 92, 95–100.
14. Saito, I., Hisanaga, N., Takeuchi, Y., et al. (1984) Assessment of the exposure of pest
control operators to organophosphorus pesticides. Organophosphorus pesticides in blood
and alkyl phosphate metabolites in urine. Sangyo Igaku 26, 15–21.
15. Ikebuchi, J., Yuasa, I., and Kotoku, S. (1988) A rapid and sensitive method for the determination of paraquat in plasma and urine by thin-layer chromatography with flame ionization detection. J. Anal. Toxicol. 12, 80–83.
16. Gellhaus, H., Hausmann, E., and Wellhoner, H. H. (1989) Fast determination of demetonS-methylsulfoxide (metasystox R) in blood plasma. J. Anal. Toxicol. 13, 330–332.
17. Flanagan, R. J. and Ruprah, M. (1989) HPLC measurement of chlorophenoxy herbicides,
bromoxynil, and ioxynil, in biological specimens to aid diagnosis of acute poisoning. Clin.
Chem. 35, 1342–1347.
18. Liu, J., Suzuki, O., Kumazawa, T., and Seno, H. (1989) Rapid isolation with Sep-Pak C18
cartridges and wide-bore capillary gas chromatography of organophosphate pesticides.
Forensic Sci. Int. 41, 67–72.
19. Sharma, V. K., Jadhav, R. K., Rao, G. J., Saraf, A. K., and Chandra, H. (1990) High
performance liquid chromatographic method for the analysis of organophosphorus and
carbamate pesticides. Forensic Sci. Int. 48, 21–25.
20. Junting, L. and Chuichang, F. (1991) Solid phase extraction method for rapid isolation and
clean-up of some synthetic pyrethroid insecticides from human urine and plasma. Forensic Sci. Int. 51, 89–93.
21. Tomita, M., Okuyama, T., Watanabe, S., Uno, B., and Kawai, S. (1991) High-performance
liquid chromatographic determination of glyphosate and (aminomethyl)phosphonic acid
in human serum after conversion into p-toluenesulphonyl derivatives. J. Chromatogr. 566,
239–243.
Pesticides in Human Serum/Plasma
47
22. Kawasaki, S., Ueda, H., Itoh, H., and Tadano, J. (1992) Screening of organophosphorus
pesticides using liquid chromatography–atmospheric pressure chemical ionization mass
spectrometry. J. Chromatogr. 595, 193–202.
23. Unni, L. K., Hannant, M. E., and Becker, R. E. (1992) High-performance liquid chromatographic method using ultraviolet detection for measuring metrifonate and dichlorvos levels in human plasma. J. Chromatogr. 573, 99–103.
24. Croes, K., Martens, F., and Desmet, K. (1993) Quantitation of paraquat in serum by HPLC.
J. Anal. Toxicol. 17, 310–312.
25. Smith, N. B., Mathialagan, S., and Brooks, K. E. (1993) Simple sensitive solid-phase extraction of paraquat from plasma using cyanopropyl columns. J. Anal. Toxicol. 17, 143–145.
26. Keller, T., Skopp, G., Wu, M., and Aderjan, R. (1994) Fatal overdose of 2,4-dichlorophenoxyacetic acid (2,4-D). Forensic Sci. Int. 65, 13–18.
27. Wintersteiger, R., Ofner, B., Juan, H., and Windisch, M. (1994) Determination of traces of
pyrethrins and piperonyl butoxide in biological material by high-performance liquid chromatography. J. Chromatogr. A 660, 205–210.
28. Lee, X. P., Kumazawa, T., and Sato, K. (1995) Rapid extraction and capillary gas chromatography for diazine herbicides in human body fluids. Forensic Sci. Int. 72, 199–207.
29. Qiu, H. and Jun, H. W. (1996) Solid-phase extraction and liquid chromatographic
quantitation of insect repellent N,N-diethyl-m-toluamide in plasma. J. Pharm. Biomed.
Anal. 15, 241–250.
30. Cho, Y., Matsuoka, N., and Kamiya, A. (1997) Determination of organophosphorous pesticides in biological samples of acute poisoning by HPLC with diode-array detector. Chem.
Pharm. Bull.(Tokyo) 45, 737–740.
31. Futagami, K., Narazaki, C., Kataoka, Y., Shuto, H., and Oishi, R. (1997) Application of
high-performance thin-layer chromatography for the detection of organophosphorus insecticides in human serum after acute poisoning. J. Chromatogr. B Biomed. Sci. Appl.
704, 369–373.
32. Lee, H. S., Kim, K., Kim, J. H., Do, K. S., and Lee, S. K. (1998) On-line sample preparation of paraquat in human serum samples using high-performance liquid chromatography
with column switching. J. Chromatogr. B Biomed. Sci. Appl. 716, 371–374.
33. Sancho, J. V., Pozo, O. J., and Hernandez, F. (2000) Direct determination of chlorpyrifos
and its main metabolite 3,5, 6-trichloro-2-pyridinol in human serum and urine by coupledcolumn liquid chromatography/electrospray–tandem mass spectrometry. Rapid Commun.
Mass Spectrom. 14, 1485–1490.
34. Frenzel, T., Sochor, H., Speer, K., and Uihlein, M. (2000) Rapid multimethod for verification and determination of toxic pesticides in whole blood by means of capillary GC–MS.
J. Anal. Toxicol. 24, 365–371.
35. Kawasaki, S., Nagumo, F., Ueda, H., Tajima, Y., Sano, M., and Tadano, J. (1993) Simple,
rapid and simultaneous measurement of eight different types of carbamate pesticides in
serum using liquid chromatography–atmospheric pressure chemical ionization mass spectrometry. J. Chromatogr. 620, 61–71.
36. Barr, D., Barr, J., Maggio, V., et al. (2002) A multi-analyte method for the quantification
of contemporary pesticides in human serum and plasma using high-resolution mass spectrometry. J. Chromatogr. B Analyt. Technol. Biomed. Life Sci. 778, 99.
37. Westgard, J. O. (2002) Basic QC practices: training in statistical quality control for health
care laboratories. Westgard QC, Madison, WI.
OCPs in Human Fluids by SPDE and GC–MS/ECNI
49
4
Application of Solid-Phase Disk Extraction Combined
With Gas Chromatographic Techniques for Determination
of Organochlorine Pesticides in Human Body Fluids
Adrian Covaci
Summary
A simple, rapid, sensitive procedure based on solid-phase disk extraction (SPDE) is
described for the isolation and concentration of trace levels of selected organochlorine
pesticides from human body fluids (serum, cord blood, milk, follicular and seminal fluid).
Similar methodology can be used for each matrix; the only restricting factor is the viscosity of the fluid. After denaturizing proteins with formic acid, an Empore™ C18bonded silica extraction disk cartridge is used for the extraction of the analytes.
Subsequent cleanup and lipid removal from the SPDE eluate is achieved by adsorption
chromatography on acidified silica or Florisil, depending on the interest in acid-labile
pesticides. By using the SPDE procedure, high-throughput parallel-sample processing
can be achieved. Instrumental analysis is done by gas chromatography–mass spectrometry in electron-capture negative ionization mode (GC–MS/ECNI). Recoveries for selected organochlorine pesticides range from 65 to 91% (SD < 10%) for serum and from
70 to 102% (SD < 14%) for milk. Detection limits between 10 and 100 pg/mL fluid can
be obtained. The method was validated through successful participation in several
interlaboratory tests and through the routine analysis of human serum with various loadings of organochlorine pesticides.
Key Words: Cord blood; follicular and seminal fluid; gas chromatography; milk;
organochlorine pesticides; serum; solid-phase disk extraction.
1. Introduction
Organochlorine pesticides (OCPs) are prevalent environmental contaminants with
high lipophilicity and long half-lives (1). Owing to their persistence, high potential for
accumulation in food chains and potential health effects (immunotoxicity, reproductive effects, endocrine disruption, and neurotoxicity), the monitoring of OCPs in
humans is of high general concern (2,3). Monitoring of human exposure to OCPs is
most conveniently performed by analysis of blood plasma, blood serum, or milk. The
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
49
50
Covaci
requirements for risk assessment in epidemiological studies have created the need for
efficient, fast, and less-costly analytical methods.
Because of trace levels found in biological fluids and the presence of other extraneous chemicals at higher concentrations, a highly sensitive and selective multistage
analytical procedure is needed. The determination of OCPs by gas chromatography
(GC) usually requires preliminary purification of the extracts before instrumental
analysis. Conventional methods of separating OCPs from human body fluids involve
liquid–liquid extraction with nonpolar solvents (4,5). They are very complex, labor
intensive, and time consuming and use excessive amounts of solvents and reagents.
Solid-phase extraction (SPE), using commercially available columns prepacked with
various stationary phases, has been investigated as an alternative method for extraction and cleanup (6–10).
The use of solid-phase disk extraction (SPDE) technology has been reported for the
first time for the analysis of OCPs and polychlorinated biphenyls (PCBs) in human
serum (11–13). The procedure involves denaturation of serum proteins with formic
acid, SPE using C18 Empore™ disk cartridges, followed by elimination of lipids using
cleanup on acidified silica or Florisil. The use of SPDE improves the assay throughput
and seems promising for its simplicity, reliability, low solvent consumption, minimal
cross-contamination from high-level samples, parallel sample processing, and time
reduction. The above-described method has been successfully applied to several monitoring studies (14–18).
This chapter provides a reliable, simple, rapid, and sensitive methodology for the
routine analysis of OCPs in various human body fluids, such as serum, plasma, cord
blood serum, milk, and seminal and follicular fluids.
2. Materials
1. Analytical standards hexachlorobenzene (HCB); α-, β-, and γ-hexachlorocyclohexane (HCH) isomers; o,p'-DDE, p,p'-DDE, o,p'-DDD, p,p'-DDD, o,p'-DDT, p,p'-DDT;
trans-chlordane; cis-chlordane; trans-nonachlor; oxychlordane; dieldrin; heptachlorepoxide; heptachlor; and mirex (e.g., from Dr. Ehrenstorfer, Augsburg, Germany) at a
concentration of 10 ng/µL in iso-octane or cyclohexane. A stock solution (500
pg/µL) containing all analytes is prepared, and further dilutions to 200, 50, 10,
and 1 pg/µL are made with iso-octane in volumetric flasks.
2. Internal standards (ε-HCH and PCB 143) and syringe standard (1,2,3,4tetrachloronaphthalene [TCN]; e.g., from Dr. Ehrenstorfer) at a concentration of 10 ng/
µL in iso-octane or cyclohexane. Dilutions to a concentration of 100 pg/µL for internal
standard and 500 pg/µL for syringe standard are made with iso-octane in volumetric
flasks.
3. Methanol, acetonitrile, hexane, dichloromethane, acetone, and iso-octane (pesticide grade;
e.g. Merck, Darmstadt, Germany).
4. Formic acid 99% p.a.
5. Concentrated sulfuric acid 95 to 97% p.a. (e.g., Merck).
6. Anhydrous sodium sulfate for residue analysis, Florisil (0.15 to 0.25 mm), and silica gel
60 to 200 mesh (e.g., Merck) are washed with hexane and heated overnight at 120°C.
OCPs in Human Fluids by SPDE and GC–MS/ECNI
51
7. Human serum for method validation is provided by the Blood Transfusion Centre, University Hospital of Antwerp (Belgium). Blood is collected in a vacuum system tube and
centrifuged (15 min, 2000g) within 24 h after collection. Human milk and follicular and
seminal fluid samples are obtained from the Fertility Unit of the University Hospital of
Antwerp, Belgium. All samples are kept frozen at –20°C until analyzed.
8. All glassware is washed with detergent, rinsed with water, soaked for 24 h in sulfochromic
acid, and rinsed with distilled water, acetone, and hexane. Prior to use, the treated glassware is rinsed with the solvent with which it subsequently will contact.
9. C18 Empore™ disk extraction cartridges, 10 mm/6 mL (e.g., 3M Company).
10. Positive pressure manifold (part 1223-420X; e.g., 3M Company).
11. Empty polypropylene columns (3 mL) for cleanup (e.g., Supelco, Bellefonte, PA).
12. A GC (e.g., Hewlett Packard 6890, Palo Alto, CA) connected with a mass spectrometer
(MS) (e.g., Hewlett Packard 5973) operated in electron-capture negative ionization
(ECNI) mode.
13. A 25 m × 0.22 mm id × 0.25 mm film thickness, 8% phenyl polycarborane siloxane (HT8) capillary column.
3. Methods
Compared to classical liquid–liquid extraction methods, the use of Empore disk
technology (90% sorbent, 10% matrix–polytetrafluoroethylene [PTFE]) allows reduction of elution solvent because of small bed volume (Fig. 1). The C18 disk cartridge
employed for sample cleanup and analyte enrichment has a nonpolar character, causing retention of nonpolar compounds. It has also a size exclusion function to eliminate
macromolecular interference (such as serum proteins) in biological extracts.
A main disadvantage of the SPDE method is that lipid determination cannot be
done on the same sample aliquot because the procedure does not allow the collection
of the lipidic fraction. However, enzymatic methods are an elegant way to measure the
lipid content on a very small (<150 µL) separate serum aliquot.
The method described below outlines the (1) sample preparation and loading onto the
SPDE cartridge, (2) elution of analytes from the SPDE cartridge and cleanup of the eluate, (3) the GC analysis, (4) method validation, and (5) required quality control criteria.
3.1. Sample Preparation and Loading
3.1.1. Incubation With Internal Standards and Protein Disruption
To avoid column overloading and breakthrough of the analytes, the following
sample volumes are recommended: 1 to 5 mL plasma, serum, or cord blood serum; 1
to 3 mL milk; 1 to 2 mL seminal fluid; and 3 to 5 mL follicular fluid.
1. Spike the appropriate amount of each type of sample with internal standards ε-HCH and
PCB 143 (generally, between 5 and 10 ng/sample) (see Note 1).
2. Repeat the above procedure for procedural blanks using Milli Q water instead of samples.
3. Equilibrate the mixture in an ultrasonic bath for 30 min.
4. Incubate overnight at +4°C.
5. Prior to extraction (the next day), mix the samples with formic acid (1:1 v/v) (see Note 2).
6. Equilibrate the mixture by ultrasonic treatment for 30 min. When milk is used, it should
be diluted with Milli Q water (1:1 v/v) because of higher viscosity and the possibility of
clogging the SPDE cartridge.
52
Covaci
Fig. 1. Solid-phase disk extraction cartridge (3M Empore).
3.1.2. Conditioning the SPDE Cartridge
Prior to the sample application, the disk cartridges have to be rinsed with organic
solvent and then conditioned with methanol and water.
1. Wash the SPDE cartridge with two 500-µL portions of dichloromethane and dry it thoroughly.
2. Add to each cartridge 250 µL methanol.
3. Add two portions of 250 µL Milli Q water. Attention must be paid that, after conditioning, the cartridges should not be allowed to dry.
3.1.3. Sample Application and Drying Step
1. Load the sample to the SPDE cartridge and apply a positive-pressure nitrogen stream (see
Note 3).
2. Rinse each cartridge with two 500-µL portions of Milli Q water.
3. Dry the sorbent bed thoroughly under a nitrogen stream at 20 psi positive pressure (10
min) and then by centrifugation (15 min, 2000g) (see Note 4).
OCPs in Human Fluids by SPDE and GC–MS/ECNI
53
When applying positive pressures, low flow rates are mandatory to increase the
extraction yields, allowing longer contact time between the analytes and the sorbent.
However, compared to serum, the amount of milk that can be loaded on the SPDE
cartridge will be less because of the presence of more lipids with similar polarity as the
organochlorines and therefore higher competition for the binding sites. Furthermore,
milk samples have to be diluted with Milli Q water (1:1 v/v), and higher pressures are
needed for the sample loading.
3.2. Elution and Cleanup
Compared to classical SPE, lower solvent volumes are needed for the elution of
analytes from the SPDE cartridge (up to 1.5 mL per cartridge). The choice of cleanup
procedure is dependent on the analytes of interest. For example, if OCPs are measured
together with other potentially present persistent contaminants such as PCBs, destructive cleanup using acidified silica is preferred. The resulting extracts are cleaner than
those resulting from nondestructive cleanup, but some of the acid-labile OCPs, such
as dieldrin, endosulfans, heptachlor, and heptachlorepoxide are completely destroyed
(19). Alternatively, nondestructive cleanup using deactivated silica, alumina, or
Florisil may be used, but the resulting extracts may still contain traces of lipids and
might hinder the GC analysis (20).
3.2.1. Cleanup on Acidified Silica
The use of cleanup on acidified silica results in a lower background, which facilitates peak identification of OCPs present at very low concentrations. This cleanup
method ensures better instrumental performance and longer column lifetime.
1. Fill an empty column with 500 mg acid silica (see Note 5) and 100 mg Na2SO4.
2. Wash the filled cleanup column with 2 mL dichloromethane:hexane (1:1 v/v), followed
by 2 mL of hexane; after solvent elution, place the column under the SPDE cartridge.
3. Prepare the column setup and place the collection tube under the silica column (Fig. 2).
4. Elute the SPDE cartridge with two 500-µL portions of hexane and 500 µL
dichloromethane:hexane (1:1 v/v).
5. Remove the SPDE cartridge.
6. Elute OCPs from the silica column with 3 mL hexane and 3 mL dichloromethane:hexane
(1:1).
7. Add 50 µL iso-octane as a keeper solvent.
8. Concentrate the eluate under a gentle nitrogen stream at room temperature to near dryness.
9. Add 100 µL iso-octane and 25 µL recovery standard TCN (500 pg/µL), vortex thoroughly
for 15 s, and transfer to a GC vial.
3.2.2. Cleanup on Florisil
The use of Florisil cleanup allows determination of acid-labile analytes, but results
in a higher background in the chromatograms. Minor modifications, such as addition
of acetonitrile in the elution step, may also increase the recovery of more polar OCPs.
1. Fill an empty column with 1 g activated Florisil and 100 mg Na2SO4.
2. Wash the filled cleanup column with 2 mL dichloromethane:hexane (1:1 v/v), followed
by 2 mL of hexane; after solvent elution, place it under the SPDE cartridge.
54
Covaci
Fig. 2. Cartridge setup for the OCP analysis in human body fluids.
3. Prepare the column setup and place the collection tube under the Florisil column (Fig. 2).
4. Elute the SPDE cartridge with two 500-µL portions of hexane and 500 µL
dichloromethane:hexane (1:1 v/v).
5. Remove the SPDE cartridge.
6. Elute OCPs from the Florisil column with 3 mL hexane, 3 mL dichloromethane:hexane
(1:1), and 500 µL acetonitrile.
7. Add 50 µL of iso-octane as a keeper solvent.
8. Concentrate the eluate under a gentle nitrogen stream at room temperature to near dryness.
OCPs in Human Fluids by SPDE and GC–MS/ECNI
55
Table 1
Ion Fragments Monitored for Each Compound or Group of Compounds
Group of compounds
TCN (syringe standard)
PCB 143
o,p'- and p,p'-DDE
o,p'- and p,p'-DDD
o,p'- and p,p'-DDT
trans- and cis-Chlordane
trans-Nonachlor
Oxychlordane
Dieldrin
Mirex
Heptachlor
Heptachlorepoxide
ε-HCH
α-, β-, and γ-HCH
HCB
Quantification ion
Qualification ion
266
360
318
71
71
408
442
350
380
368
272
388
71
71
284
264
362
316
248
248
410
444
424
237
370
71
71
255
255
286
9. Add 100 µL iso-octane and 25 µL recovery standard TCN (500 pg/µL), vortex thoroughly
for 15 s, and transfer to a GC vial.
3.3. GC–MS Analysis
The final cleaned extract (1 µL) is injected in pulsed splitless mode (280°C injector
temperature, 30-psi pressure pulse, 1.5-min pulse time, 1.5-min splitless time) into the
GC. Helium is used as carrier gas at a constant flow of 1.0 mL/min with an initial
pressure of 14.40 psi. The temperature of the HT-8 column (see Note 6) is programmed
from 90 (1.50 min) to 200°C (2.0 min) at a rate of 15°C/min, to 270°C (1.0 min) at a
rate of 5°C/min, and finally to 290°C (10 min) at a rate of 25°C/min.
Low-resolution quadrupole MS is used in ECNI mode (methane moderating gas) to
increase the sensitivity of OCP determination. The ion source, quadrupole, and interface temperatures are 150, 130, and 300°C, respectively. Two most abundant ions (if
possible including the molecular ion) are monitored for OCP (Table 1). Dwell times
are set at 50 ms.
3.4. Method Validation
3.4.1. Recoveries
To test the method performance, recoveries of internal standards and analytes
should be determined from each matrix. However, because of small sample volumes
of cord blood serum and follicular and seminal fluid, only recoveries of internal standards can be measured.
1. Five replicates at one spiking level and five nonspiked replicates from the same batch of
pooled body fluid have to be analyzed.
56
Covaci
Table 2
Recoveries of Internal Standards
Mean percentage recoveries (SD)
Matrix
ε-HCH
PCB 143
Maternal serum
Cord serum
Human milk
Follicular fluid
Seminal fluid
68 (8)
62 (7)
73 (5)
53 (17)
67 (11)
65 (9)
61 (5)
75 (7)
48 (12)
68 (14)
2. Calculate absolute recoveries of OCPs after subtracting the levels found in the nonspiked
replicates from the spiked ones.
Recoveries of internal standards (ε-HCH and PCB 143) calculated from each fluid
range from 48% (follicular fluid) to 76% (human milk), and relatively good reproducibility (SD < 12% for serum, cord blood, and milk and < 17% for follicular and seminal fluids) may be achieved (Table 2). The lower recoveries for follicular fluid can be
explained by the higher speed through the extraction cartridge (thus a lower contact
time) because of lower viscosity.
Recoveries of selected OCPs in serum range from 66 to 88% (SD < 9%) when the
acidified silica cleanup is used. The Florisil cleanup results in recoveries between 65
and 91% (SD < 10%). For human milk, analyte recoveries range from 70 to 102% (SD
< 14%) for all analytes at a fortification level similar to normal values in human milk.
3.4.2. Detection Limits
The limit of detection for each analyte is calculated as the sum between the mean of
the detected signal at the analyte retention time in procedural blanks (five replicates)
and 3 × SD of the signal. Typical detection limits range between 10 and 100 pg/mL for
the investigated human body fluids.
3.4.3. Linearity
Linearity should be tested with a lack-of-fit test for intervals that include the normal range of pollutants in human body fluids (0.02 to 10 ng/mL in human serum, cord
blood serum, and follicular and seminal fluids and 0.02 to 50 ng/mL in human milk).
The correlation coefficient r2 should not be used to assess linearity unless already
verified by a lack-of-fit test (21).
3.5. Quality Control
Because of extremely low levels of analytes that need to be measured in small
sample volumes and the high probability of errors at these concentrations, adequate
quality control needs to be applied before data reporting.
3.5.1. Internal Quality Control
Several procedures are usually applied to ensure adequate quality:
OCPs in Human Fluids by SPDE and GC–MS/ECNI
57
1. Review manually all peaks for proper integration.
2. Identify OCPs based on their relative retention times to the internal/recovery standards,
based on the selected ion chromatograms and based on the ratios between abundance of
the quantification ion and the qualifier ion. A deviation of ion ratios of less than ±15%
from the theoretical value is considered acceptable.
3. For calibration, plot peak area ratios (OCPs area/internal standard area) against the amount
ratios (OCPs amount/internal standard amount).
4. Run calibration curves with each sample batch and check that the correlation coefficients
are kept above 0.99.
5. With each sample batch, analyze procedural blanks and inject standard solutions that
include all analytes to assess variations in chromatographic and instrument performance
and to check for interference.
6. Measure recoveries of internal standards in each sample to monitor their variation.
7. Analyze an in-house control serum (laboratory reference material) with every sample
batch. The control serum is obtained from human serum (about 50 donations) from the
Blood Transfusion Center, University Hospital of Antwerp, Belgium. The serum (approx
100 mL) is pooled and homogenized. Aliquots of 7 mL are divided into hexane-washed
glass vials and kept at –20°C. Monitor the variation in concentrations of the measurable
analytes (such as p,p′-DDE and β-HCH) and set confidence and control intervals as mean
± 2SD and mean ± 3 SD, respectively (22). Plot a control chart for the variation in time of
concentrations of relevant analytes measured in the in-house control serum.
8. Certified reference materials such as SRM 1588a (PCBs and OCPs in human serum, National Institute for Standards and Technology, United States) should be used at regular
intervals.
3.5.2. External Quality Control
External quality control is usually done through adherence to internationally recognized interlaboratory tests. Several such studies for human serum/plasma are available
throughout the year, with a larger participation at the Arctic Monitoring and Assessment Programme (AMAP) ring test, organized by the Toxicological Centre of Québec
(Canada) or at the Quality Assurance Assay in Occupational and Environmental Medicine run by the University of Erlangen (Germany). Several OCPs, such as HCB, βHCH isomers, p,p′-DDE, p,p′-DDT, and oxychlordane are requested to be measured
in naturally contaminated or spiked serum samples at environmental levels.
4. Notes
1. The selection of internal standards is based on the GC elution characteristics and on their
absence in the samples. PCB 143 has been shown to be a suitable internal standard for
most OCPs (except HCHs), and it can also be used for the determination of PCBs, normally measured in the same extracts. Use of other internal standards, such as more expensive 13C-labeled OCPs, is encouraged, but in this case the extracts cannot be analyzed by
electron capture detector, which may provide better sensitivity for low traces of analytes.
All samples need to be spiked with the internal standards dissolved in ethanol or acetone
instead of hexane or iso-octane because the presence of nonpolar solvent was found to
reduce recoveries of all compounds (especially the most lipophilic compounds).
2. Formic acid is chosen as a deproteination agent because it yields the highest analyte recoveries on the SPDE cartridge (11) and because it does not degrade acid-sensitive
58
3.
4.
5.
6.
Covaci
analytes (19). The serum pretreatment by denaturation without precipitation is found to
release the analytes from the binding sites without the possible loss by occlusion in the
precipitate (11). The fact that no precipitate is formed during the denaturation makes this
method compatible with the SPDE cartridge. Reduced pH (adjusted by the addition of
formic acid) increases the extraction efficiency of the C18 sorbent. The denaturation of
milk proteins and disruption of fat globules is also done by addition of formic acid and
ultrasonication. Sodium oxalate or methanol (or short-chain alcohol for reduced viscosity) (6) may also be used for this purpose. However, the denaturated samples, when not
processed immediately (<1 h), sometimes form a gel-like precipitate that would prevent
immediate extraction, as also reported elsewhere (10). When samples are left capped and
in a refrigerator for 2 to 3 h, the gel would dissipate, allowing proper SPDE column flow
and analyte extraction.
The use of slower flow rates (2 to 4 psi) allows maximal residence time of the solvents in
the sorbent bed and yields slightly improved recoveries than higher flow rates (10 to 15 psi).
The drying step is essential because the nonpolar eluents (hexane and dichloromethane)
need to interact with all areas of the sorbent and should not be hindered by residual water
trapped in the pores. Centrifugation of the cartridges before elution of OCPs is necessary
because of the high compactness of the adsorbent bed, making complete drying difficult.
The acid silica is prepared as follows: To 50 g silica gel, 27 mL concentrated sulfuric acid
(95 to 97%) were added dropwise while the mixture was stirred with a magnetic stir bar to
ensure good homogeneity. After the addition of acid, the acid silica is stirred for another
30 min.
Although other types of stationary phase may as well be used for the determination of
OCPs, the selection of the HT-8 column is driven by its excellent separation characteristics for PCBs (23), which are often measured together with OCPs in routine analysis.
References
1. Simonich, S. L., and Hites, R. A. (1995) Global distribution of persistent organochlorine
compounds. Science 269, 1851–1854.
2. Colosio, C., Tiramani, M., and Maroni, M. (2003) Neurobehavioral effects of pesticides:
state of the art. Neurotoxicology 24, 577–591.
3. Fleeger, J. W., Carman, K. R., and Nisbet, R. M. (2003) Indirect effects of contaminants in
aquatic ecosystems. Sci. Total Environ. 317, 207–233.
4. Greizerstein, H. B., Gigliotti, P., Vena, J., Freudenheim, J., and Kostyniak, P.J. (1997)
Standardization of a method for the routine analysis of PCB congeners and selected pesticides in human serum and milk. J. Anal. Toxicol. 21, 558–566.
5. Najam, A. R., Korver, M. P., Williams, C. C., Burse, V. W., and Needham, L. L. (1999)
Analysis of a mixture of PCBs and chlorinated pesticides in human serum by column
fractionation and dual-column capillary gas chromatography with ECD. J. AOAC Int. 82,
177–185.
6. Mañes, J., Font, G., and Pico, Y. (1993) Evaluation of a SPE system for determining
pesticide residues in milk. J. Chromatogr. 642, 195–204.
7. Dmitrovic, J., Chan, S. C., and Chan, S. H. Y. (2002) Analysis of pesticides and PCB
congeners in serum by GC/MS and SPE cleanup. Toxicol. Lett. 134, 253–258.
8. Barr, J. R., Maggio, V. L., Barr, D. B., et al. (2003) New high-resolution mass spectrometric approach for the measurement of polychlorinated biphenyls and organochlorine pesticides in humans serum. J. Chromatogr. B 794, 137–148.
OCPs in Human Fluids by SPDE and GC–MS/ECNI
59
9. Pitarch, E., Serrano, R., Lopez, F. J., and Hernandez, F. (2003) Rapid multiresidue determination of organochlorine and organophosphorus compounds in human serum by solidphase extraction and gas chromatography coupled to tandem mass spectrometry. Anal.
Bioanal. Chem. 376, 189–197.
10. Sandau, C. D., Sjödin, A., Davis, M. D., et al. (2003) Comprehensive solid-phase extraction method for persistent organic pollutants. Validation and application to the analysis of
persistent chlorinated pesticides. Anal. Chem. 75, 71–77.
11. Pauwels, A., Wells, D. A., Covaci, A., and Schepens, P. (1998) Improved sample preparation method for selected persistent organochlorine pollutants in human serum using solidphase disk extraction with gas chromatographic analysis. J. Chromatogr. B 723, 117–125.
12. Covaci, A. and Schepens, P. (2001) Improved determination of selected POPs in human
serum by solid phase disk extraction and GC-MS. Chemosphere 43, 439–447.
13. Covaci, A. and Schepens, P. (2001) Solid phase disk extraction method for the determination of POPs form human body fluids. Anal. Lett. 34, 1449–1460.
14. Pauwels, A., Covaci, A., Delbeke, L., Punjabi, U., and Schepens, P. (1999) The relation
between levels of selected PCB congeners in human serum and follicular fluid. Chemosphere 39, 2433–2441.
15. Covaci, A., Hura, C., and Schepens, P. (2001) Solid phase disk extraction: an improved
method for determination of organochlorine residues in milk. Chromatographia 54,
247–252.
16. Covaci, A., Jorens, P., Jacquemyn, Y., and Schepens, P. (2002) Distribution of PCBs and
organochlorine pesticides in umbilical cord and maternal serum. Sci. Total Environ. 298,
45–53.
17. Koppen, G., Covaci, A., Van Cleuvenbergen, R., et al. (2002) Persistent organochlorine
pollutants in human serum of 50–65 years old women in the Flanders Environmental and
Health Study (FLEHS). Part 1: Concentrations and regional differences. Chemosphere 48,
811–825.
18. Covaci, A., Koppen, G., Van Cleuvenbergen, R., et al. (2002) Persistent organochlorine
pollutants in human serum of 50–65 years old women in the Flanders Environmental and
Health Study (FLEHS). Part 2: Correlations among PCBs, PCDD/PCDFs and the use of
predictive markers. Chemosphere 48, 827–832.
19. Manirakiza, P., Covaci, A., and Schepens, P. (2002) Improved analytical procedure for
determination of chlorinated pesticide residues in human serum using solid phase disc
extraction (SPDE), single-step clean-up and gas chromatography. Chromatographia 55,
353–359.
20. Bernal, J. L., Del Nozal, M. J., and Jiménez, J. J. (1992) Some observations on clean-up
procedures using sulphuric acid and Florisil. J. Chromatogr. 607, 303–309.
21. Massart, D. L., Vandeginste, B. G. M., Buydens, L. M. C., De Jong, S., Lewi, P. J., and
Smeyers-Verbeke, J. (1997) Handbook of chemometrics and qualimetrics: Part A.
Elsevier, Amsterdam.
22. Luotamo, M. and Aitio, A. (1997) Quality assurance of isomer-specific analysis of PCBs
in serum. Chemosphere 34, 965–973.
23. Frame, G. M. (1997) A collaborative study of 209 PCB congeners and 6 Aroclors on 20
different HRGC columns. Fresenius J. Anal. Chem. 357, 701–722.
Pesticide Biomonitoring in Urine
61
5
A Comprehensive Approach for Biological Monitoring
of Pesticides in Urine Using HPLC–MS/MS and GC–MS/MS
Dana B. Barr, Anders O. Olsson, Roberto Bravo,
and Larry L. Needham
Summary
Many epidemiological studies have been conducted to determine if any relation exists
between pesticide exposure and disease. Biological monitoring is a useful tool for establishing the presence and magnitude of exposures, which are essential parts of the exposure → disease continuum. In the past, we had almost limitless urine for biological
measurements, but this has changed dramatically as the study populations continue to
focus on young children, for whom urine collection is difficult, and as the number of
pesticides for which exposure information is needed has increased. To accommodate the
biological monitoring component of these studies, we refined our methods to allow maximum exposure information from a limited-volume urine sample. Using three separate
analytical methods, each requiring only 2 mL of urine, we can successfully measure 35
different pesticides or metabolites at background levels with a high degree of selectivity
and precision. We describe a comprehensive approach to biological monitoring of current-use pesticides in urine using high-performance liquid chromatography–tandem mass
spectrometry (HPLC–MS/MS) and gas chromatography–MS/MS (GC–MS/MS) with
quantification using isotope dilution.
Key Words: Biological monitoring; GC–MS/MS; HPLC–MS/MS; isotope dilution;
pesticides; urine.
1. Introduction
In 1999, an estimated 415,000 tons of conventional pesticides were applied in the
United States (1). The widespread use of pesticides and their potential relation to
adverse health outcomes have increased both public and scientific interest in pesticide
exposures. Consequently, many epidemiological studies are conducted to determine if
any relation exists between pesticide exposure and disease.
To adequately link exposure to disease, the exposure must be accurately assessed.
Biological monitoring is a useful tool for establishing the presence and magnitude of
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
61
62
Barr et al.
exposures (2). For chemicals that do not bioaccumulate in humans, urine is the primary matrix used for biological monitoring. In the past, there has been almost-limitless urine for biological measurements, but this has changed dramatically as the study
populations continue to focus on young children, for whom urine collection is more
difficult, and as the number of pesticides for which exposure information is needed
has increased. To accommodate the biological monitoring component of these studies,
we sought to refine our methods to allow maximum exposure information from a limited-volume urine sample.
Many of the methods available in the literature focus on specific pesticide classes
or individual pesticides or metabolites (3–11). Few methods are available for the analysis of markers of several classes of pesticides in the same sample in the low nanogramper-milliliter range, which is generally necessary for studies of individuals not
occupationally exposed . However, in epidemiological studies, it is often important to
measure biomarkers of many different pesticides to obtain an accurate representation
of an individual’s exposure to make adequate statistical interpretations of health outcome data. We have accomplished this in our laboratory by analyzing small aliquots
of the same urine sample using a number of different methods (8,11,12). This has
allowed us to obtain biologically based data on 35 different chemicals using approx 6
mL of urine, an amount that can easily be obtained from adults and children. The
target analytes for our methods represent pesticides from several different pesticide
classes: organophosphorus insecticides, synthetic pyrethroid insecticides, triazine herbicides, chloroacetanilide herbicides, phenoxyacetic acid herbicides, carbamates, fungicides, and fumigants as well as the topical insect repellant N,N-diethyl-m-toluamide
(Table 1, Fig. 1).
We describe a comprehensive approach to biological monitoring of current-use
pesticides in urine using high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) and gas chromatography (GC)–MS/MS with quantification
using isotope dilution. Using three separate analytical methods, each requiring only 2
mL of urine, we can successfully measure 35 different pesticides or metabolites at
background levels with a high degree of selectivity and precision. The methods we
have developed are diverse in character, but all use selective detection techniques and
isotope dilution quantification. Our methods are precise, reliable, and robust with low
limits of detection (LODs).
2. Materials
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
Pesticide quality solvents acetonitrile, methanol, diethyl ether, hexane, and toluene.
Pesticides and their labeled standards with purity higher than 99% (see Table 2).
n-Butyl chloride (BuCl).
Glacial acetic acid, sulfuric acid, and hydrochloric acid (HCl).
Sodium acetate, sodium hydroxide, and sodium sulfate.
0.2M acetate buffer.
Tetrabutylammonium hydrogen sulfate (TBAHSO4).
β-Glucorinidase/sulfatase from Helix pomatia (G 0751, EC 3.2.1.31, type H-1).
Deionized water.
Nitrogen (>99.999% purity).
Zero air.
Pesticide Biomonitoring in Urine
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
63
Argon.
Methane.
SuporCap-100 filtration capsule.
Volumetric flasks.
Automatic pipets with disposable tips.
15-mL glass centrifuge tubes.
Qorpak glass bottles (30 mL) with Teflon caps.
Oven or dry bath set at 37°C.
Dry bath set at 60°C.
Oasis HLB 3-cc solid-phase extraction (SPE) cartridges.
Vacuum manifold for SPE.
Commercial lyophilizer or freeze-dryer.
Chem Elut (Varian, Sunnyvale, CA) sorbent-immobilized liquid extraction cartridges.
TurboVap LV.
High-performance liquid chromatograph (e.g., Agilent 1100, Palo Alto, CA) (2).
Triple quadrupole MS (e.g., Sciex API4000, Applied Biosystems, Foster, City, CA).
Triple quadrupole MS (e.g., TSQ 7000 ThermoQuest, San Jose, CA) (3).
Trace gas chromatograph with split/splitless injector (2).
CTC A200S autosampler (2).
Betasil C18 HPLC column (5-µm particle size, 100-A pore size, 1 mm id × 100 mm long).
Betasil phenyl HPLC column (5-µm particle size, 100-A pore size, 4.6 mm id × 100 mm long).
DB5-MS GC column (0.25-µm film, 0.25-mm id).
Deactivated fused silica GC column.
3. Methods
3.1. Quality Control Materials
1. For quality control (QC) materials, collect approx 20 L urine from multiple anonymous
donors.
2. Combine urine collected and mix.
3. Dilute urine with water (1:1 v/v) to reduce endogenous levels of the analytes of interest.
4. Mix overnight at 20°C.
5. Pressure filter urine through a 0.45-µm SuporCap™ -100 capsule (e.g., Pall Corp., Ann
Arbor, MI).
6. Divide urine into three equal-volume pools.
7. Spike first pool (low concentration; QCL) with approx 30–60 µg of each target analyte
(Table 1). Mix overnight at 20°C to homogenize (see Note 1).
8. Spike second pool with 100–120 µg of each target analyte (Table 1). Mix overnight at
20°C to homogenize (see Note 2).
9. Do not spike last pool (see Note 3).
10. Aliquot urine pools into 30-mL Qorpak glass bottles with Teflon caps. Label and freeze
at –70°C until needed.
3.2. Standard Preparation
3.2.1. Multiclass Method
3.2.1.1. LABELED STANDARDS
1. Weigh 0.5 mg of each labeled standard (Table 3) into a 25-mL volumetric flask.
2. Dilute to mark with acetonitrile.
3. Dilute mixture 1:20 with acetonitrile (see Note 4).
64
Table 1
The Target Analytes, Abbreviations, Their Metabolic Status, and Parent Pesticide
and Class
Type of
marker
64
Abbreviation
Atrazine mercapturate
Acetochlor mercapturate
Metolachlor mercapturate
Alachlor mercapturate
2,4,5-Trichlorophenoxyacetic acid
2,4-Dichlorophenoxyacetic acid
4-Nitro-phenol
5-Chloro-1-isopropyl-[3H]-1,2,4-triazol-3-one
3-Chloro-4-methyl-7-hydroxycoumarin
2-Diethylamino-6-methyl pyrimidin-4-ol
2-[(Dimethoxyphosphorothioyl)sulfanyl]succinic acid
3,5,6-Trichloro-2-pyridinol
2-Isopropyl-6-methyl-4-pyrimidiol
Dimethylphosphate
ATZ
Conjugate
ACE
Conjugate
MET
Conjugate
ALA
Conjugate
2,4,5-T
Parent
2,4-D
Parent
PNP
Metabolite
CIT
Metabolite
CMHC
Metabolite
DEAMPY
Metabolite
MDA
Metabolite
TCPY
Metabolite
IMPY
Metabolite
DMP
Metabolite
organophosphorus
pesticides (OPI)
DMTP
Metabolite
organophosphorus pesticides
(OPI)
DMDTP
Metabolite
organophosphorus pesticides
(OPI)
DEP
Metabolite
organophosphorus pesticides
(OPI)
DETP
Metabolite
organophosphorus
pesticides (OPI)
Dimethylthiophosphate
Dimethyldithiophosphate
Diethylphosphate
Diethylthiophosphate
Indicator of exposure
to (pesticide classa)
Atrazine (TAH)
Acetochlor (CAH)
Metolachlor (CAH)
Alachlor (CAH)
2,4,5-T (PH)
2,4-D (PH)
Parathiona (OPI)
Isazophosa (OPI)
Coumaphosa (OPI)
Pirimiphosa (OPI)
Malathiona (OPI)
Chlorpyriphosa (OPI)
Diazinona (OPI)
O,O-Dimethyl-substituted
O,O-Dimethyl-substituted thio
O,O-Dimethyl-substituted dithio
O,O-Diethyl-substituted
O,O-Diethyl-substituted thio
Barr et al.
Analyte name
(Continued)
4-Fluoro-3-phenoxy benzoic acid
3-Phenoxy benzoic acid
65
cis-3-(2,2-Dibromovinyl)-2,2-dimethylcyclopropane1-carboxylic acid
cis and trans-3-(2,2-Dichlorovinyl)-2,2dimethylcyclopropane-1-carboxylic acids
N,N-Diethyl-m-toluamide
2-Isopropoxyphenol
2,3-Dihydro-2,2-dimethyl-7-hydroxybenzofuran
(carbofuranphenol)
1-Naphthol
2-Naphthol
ortho-Phenylphenol
2,5-Dichlorophenol
2,4-Dichlorophenol
2,4,5-Trichlorophenol
2,4,6-Trichlorophenol
Pentachlorophenol
DEDTP
Metabolite
organophosphorus pesticides
(OPI)
4-F-3-PBA
Metabolite
3-PBA
Metabolite
pyrethroids in the United
States (PI)
DBCA
Metabolite
O,O-Diethyl-substituted dithio
Cyfluthrin (PI)
10 of 18 commercially available
deltamethrin (PI)
cis-/transMetabolite
Cyfluthrin, permethrin,
DCCA
cypermethrin (PI)
DEET
Parent
DEET (IR)
IPP
Metabolite
Propoxur (CI)
CFP
Metabolite
Carbofuran, benfuracarb,
carbosulfan, furathiocarb (CI)
1N
Metabolite
Carbaryl (CI); naphthalene
(FG, PAH)
2N
Metabolite
Naphthalene (FG, PAH)
OPP
Parent
OPP (F)
25DCP
Metabolite
para-Dichlorobenzene (FG, CH)
24DCP
Metabolite
meta-Dichlorobenzene (CH)
245TCP
Metabolite/
245TCP, trichlorobenzene,
parent
pentachlorophenol, lindane (CH)
246TCP
Metabolite/parent
246TCP, trichlorobenzene,
pentachlorophenol, lindane (CH)
PCP
Parent
Pentachlorophenol (F)
Pesticide Biomonitoring in Urine
Diethyldithiophosphate
CAH, chloroacetoanilides herbicides; CH, chlorinated hydrocarbon; CI, carbamate insecticide; F, fungicide; FG, fumigant; IR, insect repellant; OPI, organophosphate insecticides; PAH, polycyclic aromatic hydrocarbon; PH, phenoxyacetic acid herbicides; PI, pyrethroid insecticides; TAH, triazine herbicides.
aOr their methyl counterparts.
65
66
66
Barr et al.
Fig. 1. Structures of target analytes (abbreviations according to Table 1).
Pesticide Biomonitoring in Urine
67
Table 2
Optimized Precursor/Product Ion Pairs and the Collision Offset Energy (CE)
for the Dialkylphosphate Method Target Analytes on the TSQ 7000 Mass Spectrometer
Analyte
(label pattern)
DMP (d6)
DMTP (d10)
DMDTP (d6)
DEP (d6)
DETP (d10)
DEDTP (13C4)
Precursor ion
Native
Labeled
203
219
235
231
247
263
Product ion
Native
Labeled
209
225
241
241
257
267
127
143
125
127
191
153
133
149
131
133
193
157
CE
(V)
Ion
mode
–12
–13
–10
–13
–12
–12
+
+
+
+
+
+
4. Aliquot into 1-mL ampules and flame seal.
5. Store at –20°C until used.
3.2.1.2. NATIVE STANDARDS
1. Weigh 5 mg of each target analyte (Table 4) into a 25-mL flask (see Note 5).
2. Dilute to marks with acetonitrile to create individual stock solutions.
3. Prepare eight calibration standard spiking solutions at the following concentrations: 0.020,
0.040, 0.080, 0.20, 0.40, 0.80, 2.0, and 4.0 µg/mL (see Notes 6 and 7).
4. Divide into 1-mL aliquots in glass ampules and flame seal.
5. Store at –20°C until used.
3.2.2. Dialkylphosphate Method
3.2.2.1. LABELED STANDARDS
1.
2.
3.
4.
Weigh 0.5 mg of each isotopically labeled analyte into a 100-mL volumetric flask.
Dilute to mark with acetonitrile (see Notes 8 and 9).
Divide solution into 1-mL aliquots in glass ampules and flame seal.
Store at –20°C until used.
3.2.2.2. NATIVE STANDARDS
1. Seven sets of calibration spiking standards in acetonitrile with analyte concentrations
ranging from 0.0145–1.7 ng/µL are prepared under contract by Battelle Memorial Institute (Bel Air, MD) (see Note 10).
3.2.3. Phenols Method
3.2.3.1. LABELED STANDARDS
1. Prepare individual stock-labeled internal standard (ISTD) solutions by weighing approx
0.5 mg of each of the isotopically labeled analytes (Table 4) into a 2.5-mL volumetric
flask (see Note 11).
2. Dilute to marks with acetonitrile to yield 200-µg/mL solutions.
3. Prepare a multiple-analyte standard solution by adding 250 µL of each individual stock
solution into a 5-mL volumetric flask.
4. Dilute to mark with acetonitrile to obtain a final concentration of 10 ng/µL (see Note 12).
5. Divide all solutions into 1-mL aliquots in ampules and flame seal.
6. Store at –20°C until used.
68
Barr et al.
Table 3
Pesticides and Their Labeled Standards
Pesticide
Labeled standard
Acetochlor mercapturate (N-acetyl-S-[2-(2-ethyl-6methylphenyl)(ethoxymethyl)amino]-2-oxoethyl-L-cysteine) (ACE)
Alachlor mercapturate (N-acetyl-S-[2-(2,6diethylphenyl)(methoxymethyl)amino]-2-oxoethyl-L-cysteine)
(ALA)
Metolachlor mercapturate (N-acetyl-S-[2-(2-ethyl-6-methylphenyl)(2methoxy-1-methylethyl)amino]-2-oxoethyl-L-cysteine) (MET)
5-Chloro-1,2-dihydro-1-isopropyl-[3H]-1,2,4-triazol-3-one (CIT)
3-Chloro-4-methyl-7-hydroxycoumarin (CMHC)
2-Diethylamino-6-methyl pyrimidin-4-ol (DEAMPY)
2-Isopropyl-6-methyl-4-pyrimidiol (IMPY)
3,5,6-Trichloro-2-pyridinol (TCPY)
N,N-Diethyl-m-toluamide (DEET)
2-[(Dimethoxyphosphorothioyl)sulfanyl]succinic acid) (MDA)
Atrazine mercapturate (N-acetyl-S-[4-(ethylamino)-6-[(1methylethyl)amino]-1,3,5-triazin-2-yl]-L-cysteine) (ATZ)
2,4-Dichlorophenoxyacetic acid (2,4-D)
2,4,5-Trichlorophenoxyacetic acid (2,4,5-T)
2, 5-Dichlorophenol (25DCP)
2,4-Dichlorophenol (24DCP)
2,4,5-Trichlorophenol (245TCP)
ortho-Phenyl phenol (OPP)
Pentachlorophenol (PCP)
4-Nitrophenol (PNP)
2,4,6-Trichlorophenol (246TCP)
1-Naphthol (1N)
2-Naphthol (2N)
cis- and trans-3-(2,2-Dichlorovinyl)-2,2-dimethylcyclopropane-1carboxylic acids (cis-DCCA, trans-DCCA)
4-Fluoro-3-phenoxybenzoic acid (4F3PBA)
cis-3-(2,2-Dibromovinyl)-2,2-dimethylcyclopropane-1-carboxylic
acid (DBCA)
3-Phenoxybenzoic acid (3PBA)
Dimethylphosphate (DMP)
Diethylphosphate (DEP)
Diethylthiophosphate (DETP)
Diethyldithiophosphate (DEDTP)
Dimethylthiophosphate (DMTP)
Dimethyldithiophosphate (DMDTP)
13C
6
ACE
13C
6
ALA
13C
6
MET
d7 CIT
13C
4 CMHC
d6 DEAMPY
13C IMPY
4
13C 15N TCPY
5
d6 DEET
d7 MDA
13C ATZ
3
13C
6
13C
6
13C
3
24D
245T
13C 25DCP
6
13C 2,4DCP
6
13C 245TCP
6
13C OPP
6
13C PCP
6
13C PNP
6
13C 246TCP
6
13C IN
6
Carbofuranphenol (CFP)
13C
trans-DCCA
6 3PBA
d6DMP
d DEP
10
d DETP
10
13C DEDTP
4
d DMTP
6
d DMDTP
6
Precursor ion
Analyte
(label pattern)
69
trans-DCCA
(13C2)
cis-DCCAa
DBCA a
3PBA (13C6)
4F3PBAb
IMPY (13C4)
DEAMPY (d6)
CIT (d7)
ATZ (13C3)
ACE (13C6)
ALA (13C6)
DEET (d6)
MDA (d7)
PNP (13C6)
CMHC (13C4)
MET (13C6)
2,4-D (13C6)
TCPY 1 (13C515N)
TCPY 2 c
(13C515N)
2,4,5-T (13C6)
3-PBA (13C6)
Product ion
CE
(V)
CXP
(V)
(V)
Sciex
–
–50
30
–5
88
158
121
217
130
168
119
147
114
148
286
167
204
Sciex
Sciex
Sciex
Sciex
TSQ
TSQ
TSQ
TSQ
TSQ
TSQ
TSQ
TSQ
TSQ
TSQ
TSQ
TSQ
TSQ
–
–
–
−
+
+
+
+
+
+
+
−
−
−
−
–
−
–50
–35
–55
–60
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
30
18
28
36
–22
–22
–24
–23
−15
−25
−22
13
22
24
21
18
15
–5
–3
–7
–17
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
202
203
99
−
TSQ
TSQ
15
NA
−
16
NA
NA
25
NA
Labeled
Native
Labeled
207
210
35
35
a
35
79
93
93
84
154
120
214
130
162
119
141
108
145
280
161
198
NA
196
197
93
a
207
294
213
231
153
182
203
343
351
365
192
273
138
209
409
219
198
TSQ
196
255
213
a
219
b
157
188
210
346
357
371
198
280
144
213
415
225
204
NA
202
261
219
a
99
b
69
NA, parameter not applicable to instrument used.
aLabeled trans-DCCA used as internal standard.
bLabeled 3-PBA used as internal standard.
cConfirmation ion.
Ion
Instrument
DP
Mode
Native
Pesticide Biomonitoring in Urine
Table 4
Optimized Precursor/Product Ion Pairs, Declustering Potential (DP), Collision Cell Exit Potential (CXP), and the Collision Offset
Energy (CE) for the Multianalyte Method Target Analytes on the Sciex API4000 and TSQ 7000 Mass Spectrometers
70
Barr et al.
3.2.3.2. NATIVE STANDARDS
1. Prepare a native standard stock solution by weighing approx 5 mg of the native standard
into a 25-mL volumetric flask.
2. Dilute with acetonitrile to yield a 200-ng/µL solution.
3. Prepare a set of seven standard solutions at the following concentrations by diluting stock
solutions with acetonitrile: 0.05, 0.1, 0.25, 0.5, 1, 2.5, and 5 µg/mL (see Note 13).
4. Divide into 1-mL aliquots in glass ampules and flame seal.
5. Store at –20°C until used.
3.3. Sample Preparation
3.3.1. Multiclass Method
1. Pipette 2-mL aliquots (2 mL) of urine into centrifuge tubes.
2. Spike with 25 µL isotopically labeled ISTD giving an approx 25 ng/mL concentration of
the standards in the urine (12).
3. Add 1.6 mg β-glucuronidase/sulfatase dissolved in 1.5 mL of a 0.2 M acetate buffer to
each sample (see Notes 14 and 15).
4. Incubate in a dry bath or oven at 37°C for 17 h (see Note 16).
5. Place Oasis SPE cartridges on vacuum manifold.
6. Condition Oasis SPE cartridges with 1 mL methanol followed by 1 mL 1% acetic acid.
7. Pass urine hydrolysates through the preconditioned cartridges.
8. Wash cartridges with 1 mL 5% methanol in 1% acetic acid.
9. Dry cartridges for approx 30 s using a vacuum.
10. Elute SPE cartridges with 1.5 mL methanol and collect.
11. Add 2 mL acetonitrile to the methanol eluates (see Note 17).
12. Evaporate to dryness using a Turbovap LV at 40°C and 10 psi of nitrogen as the evaporating gas.
13. Reconstitute the dried residue in 50-µL acetonitrile.
14. Separate extract into 10 and 40 µL fractions for analysis using HPLC with turbo ionspray
atmospheric pressure ionization (TSI)–MS/MS and HPLC with atmospheric pressure
chemical ionization (APCI)–MS/MS, respectively.
3.3.2. Dialkylphosphate Method
1. Pipet 2 mL urine into 15-mL centrifuge tubes.
2. Spike with 10 µL of the ISTD solution and mix to give urinary ISTD concentrations of 25
µg/L for each analyte (8,15).
3. Place in a commercial lyophilizer system.
4. Operate lypophilizer overnight in the program mode without further manual manipulation: Freeze samples for 4 h at –34°C and atmospheric pressure. Apply vacuum to 25.5
mTorr at –34°C for 4 h. Samples are taken to –20°C for 2 h, 0°C for 1 h, and finally 20°C
for 1 h.
5. Add 2 mL acetonitrile and 2 mL diethyl ether to dried residues and vortex mix for 1 min.
6. Pour supernatants into fresh 15-mL centrifuge tubes to separate them from the undissolved residue.
7. Rinse tubes with the undissolved residue with another 1 mL acetonitrile, then add to
supernatant.
8. Evaporate supernatants to approx 1 mL using a Turbovap LV at 30°C and 10 psi of nitrogen (see Note 18).
9. Pour into 15-mL test tubes containing a few grains of potassium carbonate.
Pesticide Biomonitoring in Urine
10.
11.
12.
13.
71
Add 50 µL CIP and mix.
Place in a dry bath set at 60°C for 3 h.
Transfer supernatants to clean tubes and evaporate to dryness using the TurboVap.
Reconstitute samples in 75 µL of toluene for GC–MS/MS analysis.
3.3.3. Phenols Method
1. Pipet 2 mL urine into 15-mL centrifuge tubes.
2. Spike with 5 µL of the ISTD solution to give approx 25 µg/L concentration of the ISTD in
the urine (11).
3. Add 1.8 mg β-glucuronidase/sulfatase in 2 mL 0.1 M acetate buffer to each sample (see
Notes 14 and 15).
4. Incubate in oven or dry bath for 17 h at 37°C (see Note 16).
5. Precondition Oasis SPE cartridges with 1 mL of 20% diethyl ether/n-butyl chloride, 1 mL
methanol, and 1 mL 0.05N HCl.
6. Acidify urine hydrolysates with 250 µL 2M H2SO4.
7. Pass urine through SPE cartridges.
8. Wash SPE cartridges with 5% methanol.
9. Elute cartridges with 4 mL of 20% ethyl ether/n-butyl chloride.
10. Add 1 mL of 3N NaOH to eluates and mix (see Note 19).
11. Discard organic phase.
12. Add 0.5 mL 0.4M TBAHSO4 and 0.5 mL 10% CIP in n-butyl chloride to each sample.
13. Incubate in a 60°C dry bath for 1 h to form the chloropropyl ethers of the target analytes.
14. Apply reaction mixtures to 3 cc ChemElut sorbent-immobilized liquid extraction 3-cc
cartridges.
15. Elute twice with 2 mL hexane.
16. Evaporate eluates to dryness using a Turbovap LV evaporator at 30°C and 10 psi of nitrogen for approx 30 min.
17. Reconstitute samples with 75 µL of toluene for analysis using GC–MS/MS.
3.4. Instrumental Analysis
Perform all analyses on a TSQ 7000 triple quadrupole MS (ThermoQuest) coupled
to a GC or HPLC or a Sciex API4000 triple quadrupole mass spectrometer (Applied
Biosystems/MDS Sciex) coupled to an HPLC. The HPLC apparatus should be
equipped with a binary pump, a degasser, an autosampler, and a temperature-stable
column compartment. For the APCI application, use a TSQ 7000. For the TSI application, use a Sciex API4000.
3.4.1. Multianalyte Method
1. Install a Betasil phenyl column on the HPLC connected to the TSQ 7000.
2. Set up HPLC connected to the TSQ 7000 to perform an isocratic elution with a mobile
phase mixture of 36% acetonitrile in water with 0.1% acetic acid.
3. Set the flow rate at 1.0 mL/min and the injection volume at 10 µL.
4. Keep the column temperature at 25°C during the analysis.
5. On the TSQ 7000, set the heated capillary to 450°C, the corona discharge to 4.0 kV, and
the capillary temperature to 250°C.
6. Set instrument to use 50 psi sheath gas (N2) and 2 mT collision gas (Ar).
7. Set up analysis program in the multiple reaction monitoring (MRM) mode using the parameters described in Table 3 for the TSQ 7000 target analytes.
72
Barr et al.
8. Inject each sample twice. One injection should be in the positive mode and the other in
the negative mode.
9. For the first injection, acquire data in positive ionization mode. Divide the acquisition
into two distinct timed segments, 0–3.5 and 3.5–7.25 min. The total runtime is 7.25 min.
10. For the second injection, acquire data in the negative ionization mode. Divide the acquisition into five distinct timed segments: 0–3.2, 3.2–4.3, 4.3–6.8, 6.8–9, and 9–13 min.
The total runtime is 13 min.
11. Install a Betasil C18 HPLC column to the HPLC connected to the Sciex.
12. Set up the HPLC to run an isocratic elution using a mobile phase of 51% acetonitrile in
water with 0.1% acetic acid.
13. Set the flow rate to 0.05 mL/min and the injection volume to 2 µL (see Note 20).
14. Keep the column at 35°C.
15. Set nitrogen pressure for ion source and curtain gases to 16 and 20 psi, respectively. Set
zero air for the collision-activated dissociation and heater gases to 6 and 16 psi, respectively. The heater gas is at 450°C.
16. Set the ionspray current to –4.5 kV and the entrance potential to –10 V.
17. Set up acquisition program in the MRM mode using negative ion TSI using the parameters listed in Table 3 for the Sciex target analytes.
18. Inject samples and acquire data in one segment. The total runtime is less than 9 min.
3.4.2. Dialkylphosphate Method
1. Set up GC to inject 1-µL samples via an autosampler by splitless injection with an injection purge delay of 60 s.
2. Install a DB5 MS column on the GC.
3. Ensure that a deactivated silica guard column is installed in-line preceding the GC column (see Note 20).
4. Set the temperatures of the injector and transfer line to 250°C.
5. Set up a GC program as follows: 80°C for 2 min with linear ramp to 250°C at 17°C/min.
The final temperature of 250°C is held for 2 min.
6. Set the TSQ 7000 to acquire data in the positive chemical ionization (CI+) MRM mode.
7. Set the methane (CI reagent gas) pressure to 1500 mT.
8. Set argon (collision-induced dissociation gas) pressure to 2 mT.
9. Perform a full autotune of the mass spectrometer.
10. Set TSQ parameters as follows: 150°C source temperature, 200-eV electron energy, and
the potential for the continuous dynode electron multiplier will vary depending on multiplier lifetime.
11. Set up an MRM acquisition program using the parameters outlined in Table 2 using a
mass window of 0.4 amu and a scan rate of 0.03 s–1. Divide the run into five distinct timed
segments: 7.0–7.5, 7.5–8.5, 8.5–9.2, 9.2–9.9, and 9.9–10.4 min.
3.4.3. Phenols Method
1. Set up GC to inject 1-µL samples via an autosampler by splitless injection with an injection purge delay of 60 s.
2. Install a DB5 MS column on the GC.
3. Ensure that a deactivated silica guard column is installed in-line preceding the GC column (see Note 20).
4. Set the temperatures of the injector and transfer line to 250°C.
5. Set up a GC program as follows: 80°C for 2 min, heat linearly 160°C at 10°C/min, and
Pesticide Biomonitoring in Urine
73
then heat to 260°C at 4°C/min. The final temperature of 260°C is held for 2 min.
Set TSQ 7000 to acquire data in the CI+ MRM mode.
Set the methane (CI reagent gas) pressure to 1500 mT.
Set argon (collision-induced dissociation gas) pressure to 2 mT.
Perform a full autotune of the MS.
Set TSQ parameters as follows: 150°C source temperature, 200-eV electron energy, and
vary the potential for the continuous dynode electron multiplier depending on multiplier
lifetime.
11. Set up and MRM acquisition program using the parameters outlined in Table 5 using a
mass window of 0.4 amu and a scan rate of 0.06 s–1. Divide the run into six distinct timed
segments: 9.5–11, 11–12.8, 12.8–14, 14–15.4, 15.4–16.4, and 16.4–21 min.
6.
7.
8.
9.
10.
3.5. Data Processing
1. Automatically integrate peaks using appropriate software (e.g., Xcalibur® version 2.1
from ThermoQuest provided with the TSQ 7000 or Analyst® software from Applied
Biosystems/MDX Sciex provided with the Sciex API4000).
2. Subtract the background signal and smooth data.
3. Check and correct any discrepancies in peak selection to provide an accurate integration.
4. Export peak areas and other pertinent data associated with the analysis into a Microsoft
Excel® file and load into a Microsoft Access® database for permanent storage.
5. Perform all statistical analyses using SAS software (SAS Institute Inc., Cary, NC).
3.6. Quantification and Quality Control of Analytical Runs
1. Prepare a seven- or eight-point calibration plot for quantification by spiking 2 mL blank
urine (see Subheading 3.1.) with the amount of native standard indicated vide supra (see
Subheading 3.2.; 25 µL for multiclass method, 100 µL for dialkylphosphate method, 20
µL for phenols method) (see Notes 22 and 23).
2. Spike with ISTD solution (10 µL for multiclass and dialkylphosphate methods, 5 µL for
phenols method) and mix.
3. Prepare calibration samples in parallel with unknown (N = 36) and QC (one QCL and one
QC high) samples according to methods outlined in Subheading 3.3.
4. Analyze samples according to methods outlined in Subheading 3.4.
5. Derive an equation from a linear regression analysis of the best-fit line of a plot of the
calibration standard concentrations against the areanative/areaISTD.
6. Use equation to derive concentrations of unknown samples by using each analyte
areanative/areaISTD.
7. Evaluate QC of the analytical runs using Westgard multirules for quality control (16).
3.7. Method Validation
3.7.1. Limits of Detection
1. Calculate the (LODs) as three times the standard deviation of the noise at zero concentration (17) (Table 6). The estimate of the noise should be based on the variation in precision at concentrations close to the LOD. This can be calculated using the four lowest
calibration standards from available validation and analytical runs that will provide an
integrated LOD value over several runs (see Note 24).
2. Verify the calculated LODs by comparing with the results of the calibration standard
samples to ensure that the calculated values are in agreement with the peaks observed in
the lowest calibration standards.
74
Barr et al.
Table 5
Optimized Precursor/Product Ion Pairs and the Collision Offset Energy (CE)
for the Phenols Method Target Analytes on the TSQ 7000 Mass Spectrometer
Analyte
(label pattern)
IPPa
25DCP (13C6)
24DCP (13C6)
CFPb
246TCP (13C6)
TCPY (13C515N)
PNP (13C6)
245TCP (13C6)
1N (13C6)
2Nc
OPP (13C6)
PCPd (13C6)
Precursor ion
Product ion
Native
Labeled
Native
Labeled
CE
(V)
Ion
Mode
229
239
239
247
273
274
216
273
221
221
247
228
235
245
245
247
279
280
219
279
227
227
253
234
187
163
163
199
197
198
140
197
145
145
171
NA
193
169
169
205
203
204
143
203
151
151
177
NA
5.9
7.2
7.2
7.2
7.5
7.5
10.1
7.5
10.1
10.1
13
NA
+
+
+
+
+
+
+
+
+
+
+
–
NA, not applicable.
aLabeled 25DCP and used as internal standard.
bLabeled 246TCP and used as internal standard.
cLabeled 1N and used as internal standard.
dMS analysis only.
3.7.2. Extraction Efficiency
1. Determine the extraction recovery at two concentrations by spiking five blank urine
samples (see Subheading 3.1.) with the appropriate standard concentration (Table 6).
2. Extract (and derivatize, if required) samples according to the methods in Subheading
3.3.; however, do not spike with ISTD or perform the evaporation step (see Note 25).
3. After extraction is completed, spike extract with ISTD.
4. Extract (and derivatize, if required) five additional blank urine samples (see Subheading
3.1.) according to the method in Subheading 3.3., but do not spike these samples with
native or ISTD and do not perform the evaporation step (see Note 26).
5. After the extraction is completed, spike with native standards and ISTD.
6. Evaporate samples and reconstitute in solvent according to the methods in Subheading 3.3.
7. Analyze all samples according to the methods in Subheading 3.4.
8. Calculate the recovery by comparing the responses of the blank urine samples spiked
before extraction to the responses of the blank urine samples spiked after the extraction.
These values can be expressed as a percentage.
3.7.3. Precision
Determine the precision of the method by calculating the relative standard deviation (RSD) of repeat measurements of samples from the QC pools. Multiple instruments and individuals can be used to calculate the RSDs to incorporate all sources of
analytical variation (Table 6).
Pesticide Biomonitoring in Urine
75
Table 6
Analytical Specifications of the Target Analytes
Extraction recovery
Lowlevel
levela a
Low
Method
Multiclass
Dialkyl
phosphate
Phenols
High
Highlevel
levelba
RSD (%)
Analyte
Mean
(%)
N
Mean
(%)
N
Low pool High pool LOD
(N)
(N)
(ng/mL)
MDA
PNP
CMHC
MET
24D
TCPY 1
TCPY 2c
245T
3PBA (APCI)
IMPY
DEAMPY
CIT
ATZ
ACE
DEET
3PBA (TSI)
4F3PBA
cis-DCCA
trans-DCCA
DBCA
DMP
75 ± 6
95 ± 3
95 ± 7
91 ± 9
96 ± 9
88 ± 8
93 ± 10
97 ± 5
95 ± 5
99 ± 12
98 ± 7
98 ± 20
96 ± 4
98 ± 5
96 ± 4
94 ± 4
106 ± 13
108 ± 15
95 ± 4
114 ± 18
94 ± 8
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
6
68 ± 5
93 ± 4
96 ± 13
N/A
87 ± 4
93 ± 9
94 ± 8
90 ± 2
90 ± 4
81 ± 9
95 ± 3
90 ± 11
94 ± 2
94 ± 3
93 ± 3
92 ± 2
104 ± 9
101 ± 15
92 ± 2
N/A
95 ± 10
10
10
10
NA
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
NA
6
6 (25)
6 (83)
10 (85)
9 (85)
6 (82)
9 (84)
9 (25)
6 (85)
5 (25)
11 (83)
9 (80)
14 (25)
8 (82)
8 (81)
8 (83)
7 (86)
7 (87)
14 (87)
7 (87)
15 (87)
15 (84)
5 (25)
5 (83)
9 (82)
9 (81)
6 (79)
9 (81)
6 (25)
5 (82)
5 (25)
10 (82)
8 (82)
12 (25)
6 (80)
7 (79)
8 (82)
5 (84)
6 (87)
10 (86)
5 (86)
15 (87)
11 (83)
0.3
0.1
0.2
0.2
0.2
0.3
0.4
0.1
0.2
0.7
0.2
1.5
0.3
0.1
0.1
0.1
0.2
0.2
0.4
0.1
0.6
DEP
DMTP
DMDTP
DETP
DEDTP
IPP
25DCP
24DCP
CFP
TCPY
245TCP
246TCP
PNP
1N
2N
OPP
PCP
99 ± 4
100 ± 11
100 ± 4
82 ± 6
75 ± 3
84 ± 9
93 ± 3
94 ± 3
92 ± 7
95 ± 3
80 ± 2
91 ± 6
97 ± 3
88 ± 2
97 ± 3
94 ± 5
64 ± 3
6
6
6
6
6
3
3
3
3
3
3
3
3
3
3
3
3
99 ± 4
82 ± 10
82 ± 11
87 ± 9
85 ± 3
89 ± 9
94 ± 1
92 ± 2
95 ± 6
94 ± 2
84 ± 2
95 ± 3
94 ± 3
93 ± 4
99 ± 4
93 ± 2
66 ± 1
6
6
6
6
6
3
3
3
3
3
3
3
3
3
3
3
3
13 (84)
13 (84)
15 (84)
15 (84)
13 (84)
13 (83)
14 (83)
10 (83)
11 (84)
10 (83)
17 (84)
13 (83)
8 (83)
11 (84)
11 (83)
10 (84)
10 (84)
10 (83)
10 (83)
14 (83)
14 (83)
11 (83)
12 (83)
10 (83)
12 (83)
11 (84)
9 (83)
14 (83)
14 (83)
9 (83)
9 (84)
10 (83)
8 (84)
8 (84)
0.2
0.2
0.1
0.1
0.1
0.4
0.1
0.3
0.4
0.4
0.9
1.3
0.8
0.3
0.2
0.3
0.5
LOD, limit of detection; N, number of samples tested; NA, not applicable; RSD, relative standard deviation.
a5 ng/mL for multiclass method; 10 ng/mL for dialkylphosphate method; 25 ng/mL for phenols method.
b50
ng/mL for multiclass and dialkylphosphate methods; 100 ng/mL for phenols method.
ion.
cConfirmation
76
Barr et al.
3.7.4. Intra- and Intermethod Comparison
1. Determine comparability of analytes measured in multiple methods (i.e., TCPY and 4nitro-phenol [PNP] measured in the multiclass and phenols methods) by measuring a
minimum of 25 samples using both methods.
2. Compare results from both methods. Ideally, the analyses will demonstrate agreement
within ±10%.
3. Determine comparability of 3-phenoxy benzoic acid (3PBA) concentrations using the
Sciex with TSI ionization and TSQ 7000 using APCI ionization by comparing results
from both instruments. Ideally, the analyses will demonstrate agreement within ±5%.
4. Notes
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
Target concentration of the QCL pool is 5–10 µg/L.
Target concentration of the HQCL pool is 15–20 µg/L.
Unspiked pool will serve as matrix for calibration standards and blanks.
Solution concentration is 20 µg/mL. The diluted solution is 1 µg/mL. This solution is
used as an ISTD spiked (10 µL) in all unknown samples, QC materials, and calibration
standards for the multiclass method.
cis-3-(2,2-Dibromovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (DBCA) is purchased as a 10-µg/mL acetonitrile solution so a stock solution is not made.
DBCA is not added to the two highest standard solutions because of the diluted stock
solution.
To prepare a calibration curve for the multiclass method, 25 µL of each standard solution
are added to each 2 mL blank urine sample.
Solution concentration is 5 ng/µL.
This solution is used as an ISTD spiked (10 µL) in all unknown samples, QC materials,
and calibration standards for the dialkylphosphate method.
To prepare a calibration curve for the dialkylphosphate method, 100 µL of each standard
solution are added to each 2 mL blank urine sample.
All analytes except 2-isopropoxyphenol (IPP), 2,3-dihydro-2,2-dimethyl-7-hydroxybenzofuran (carbofuranphenol, CFP), and 2-naphthol (2N) have analogous isotopically labeled
standards. For these, the closest eluting labeled analyte is used as an ISTD. Thus, for IPP,
labeled 2,5-dichlorophenol (25DCP) is used as an ISTD; for CFP, labeled 2,4,6-trichlorophenol
(246TCP) is used as an ISTD; and for 2N, 1-naphthol (1N) is used as an ISTD.
This solution is used as an ISTD spiked (5 µL) in all unknown samples, QC materials, and
calibration standards for the phenols method.
To prepare a calibration curve for the phenols method, 20 µL of each standard solution
are added to each 2 mL blank urine sample.
β-Glucuronidase/sulfatase type H-1 from Helix pomatia with a specific activity of approx
500 units/mg is used to liberate glucuronide- and sulfate-bound conjugates of metabolites
in the multiclass and phenols methods.
0.2M acetate buffer is prepared by mixing 3.1 mL glacial acetic acid, 9.7 g sodium acetate,
and 1 L water. The pH is 4.5. A 0.1M acetate buffer is made by doubling the water used.
From 1 to 6 h are required for complete hydrolysis; 17 h is a convenient time to use
because it represents the time from the end of a working day to the beginning of another
working day.
Acetonitrile forms azeotropes with residual water from SPE extraction and promotes more
efficient evaporation of the methanol eluate.
This takes about 10 min.
Pesticide Biomonitoring in Urine
77
19. Phenols are back-extracted into base, then extracted again into solvent to remove interfering components from the sample.
20. A small-diameter column and low flow is crucial for obtaining maximum sensitivity on
the Sciex application.
21. The guard column extends the useful lifetime of the GC column. When the analysis sensitivity is reduced, especially for DMP, the guard column can be easily, and inexpensively, changed.
22. The concentrations of the calibration standards should range from 0.25 to 100 ng/mL for
most analytes.
23. Best calibration results are obtained if an entire calibration sample set is generated for
each analytical run.
24. We consider the integrated LOD to be a better estimate of the method LOD because
interperson, interday, and, if applicable, interinstrument variation have all been incorporated into the resulting LODs.
25. ISTD will be added after extraction to all samples to account for instrument variability
only in the recovery calculations.
26. These samples will be reference samples indicative of 100% recovery.
References
1. Donaldson, D., Kiely, T., and Grube, A. (2002) 1998 and 1999 Market Estimates. Pesticides Industry Sales and Usage Report. US Environmental Protection Agency, Washington, DC.
2. Barr, D. B., Barr, J. R., Driskell, W. J., et al. (1999) Strategies for biological monitoring of
exposure for contemporary-use pesticides. Toxicol. Ind. Health 15, 168–179.
3. Aprea, C., Sciarra, G., and Lunghini, L. (1996) Analytical method for the determination of
urinary alkylphosphates in subjects occupationally exposed to organophosphorus pesticides and in the general population. J. Anal. Toxicol. 20, 559–563.
4. Baker, S. E., Barr, D. B., Driskell, W. J., Beeson, M. D., and Needham, L. L. (2000)
Quantification of selected pesticide metabolites in human urine using isotope dilution highperformance liquid chromatography/tandem mass spectrometry. J. Exp. Anal. Environ.
Epidemiol. 10, 789–798.
5. Beeson, M. D., Driskell, W. J., and Barr, D. B. (1999) Isotope dilution high-performance
liquid chromatography/tandem mass spectrometry method for quantifying urinary metabolites of atrazine, malathion, and 2,4-dichlorophenoxyacetic acid. Anal. Chem. 71,
3526–3530.
6. Biagini, R. E., Tolos, W., Sanderson, W. T., Henningsen, G. M., and MacKenzie, B. (1995)
Urinary biomonitoring for alachlor exposure in commercial pesticide applicators by immunoassay. Bull. Environ. Contam. Toxicol. 54, 245–250.
7. Cho, Y., Matsuoka, N., and Kamiya, A. (1997) Determination of organophosphorous pesticides in biological samples of acute poisoning by HPLC with diode-array detector. Chem.
Pharm. Bull. (Tokyo) 45, 737–740.
8. Bravo, R., Driskell, W. J., Whitehead, R. D., Needham, L. L., and Barr, D. B. (2002)
Quantification of dialkyl phosphate metabolites of organophosphate pesticides in human
urine using GC–MS/MS with isotope dilution method. J. Anal. Toxicol. 26, 245–252.
9. Cocker, J., Mason, H. J., Garfitt, S. J., and Jones, K. (2002) Biological monitoring of
exposure to organophosphate pesticides. Toxicol. Lett. 134, 97–103.
10. Drevenkar, V., Stengl, B., Tkalcevic, B., and Vasilic, Z. (1983) Occupational exposure
control by simultaneous determination of N-methylcarbamates and organophosphorus pesticide residues in human urine. Int. J. Environ. Anal. Chem. 14, 215–230.
78
Barr et al.
11. Hill, R. H., Jr., Shealy, D. B., Head, S. L., et al. (1995) Determination of pesticide metabolites in human urine using an isotope dilution technique and tandem mass spectrometry. J.
Anal. Toxicol. 19, 323–329.
12. Olsson, A., Baker, S. E., Nguyen, J. V., et al. (2004) A liquid chromatography–tandem
mass spectrometry multiresidue method for quantification of specific metabolites of organophosphorus pesticides, synthetic pyrethroids, selected herbicides, and DEET in human
urine. Anal. Chem. 76, 2453–2461.
13. Centers for Disease Control and Prevention. National Health and Nutrition Examination
Survey. National Center for Health Statistics, Hyattsville, MD. Available at: http://
www.cdc.gov/nchs/nhanes.htm.
14. Barr, D. B., Bravo, R., Weerasekera, G., et al. (2004) Concentrations of dialkyl phosphate
metabolites of organophosphorus pesticides in the US population. Environ. Health
Perspect. 112, 186–200.
15. Bravo, R., Caltabiano, L. M., Weerasekera, G., et al. (2004) Measurement of dialkyl phosphate metabolites of organophosphorus pesticides in human urine using lyophilization
with gas chromatography–tandem mass spectrometry and isotope dilution quantification.
J. Exp. Anal. Environ. Epidemiol. 15, 271–281.
16. Westgard, J. O. (2002) Basic QC Practices: Training in Statistical Quality Control for
Health Care Laboratories. Westgard QC, Madison, WI.
17. Taylor, J. K. (1987) Quality Assurance of Chemical Measurements. CRC Press, Boca
Raton, FL.
18. Centers for Disease Control and Prevention. (2003) Second National Report on Human
Exposure to Environmental Chemicals. National Center for Environmental Health, Atlanta, GA. Available at: www.cdc.gov/exposurereport.
Determination of Urinary ETU
79
6
Urinary Ethylenethiourea as a Biomarker of Exposure
to Ethylenebisdithiocarbamates
Silvia Fustinoni, Laura Campo, Sarah Birindelli, and Claudio Colosio
Summary
A method for the determination or urinary ethylenethiourea (ETU), a major metabolite of ethylenebisdithiocarbamates (EBDTCs), is described. ETU is extracted from
human urine, in the presence of ethylenethiourea-d4 as the internal standard, using
dichloromethane. The residue is reacted to form the bis-(tert-butyldimethyilsilyl) derivative and analyzed using gas chromatography–mass spectrometry (GC–MS) in the
electron impact/single-ion monitoring (EI/SIM) mode. The linearity and precision of the
assay are good over the entire investigated range (0–200 µg/L). The detection limit of
the assay after correction for urinary creatinine is 0.5 µg/g creatinine. A protocol for
biological monitoring through determination of urinary ETU is provided. The protocol
was applied to study 47 agricultural workers exposed to EBDTCs in the vineyards and
33 controls. In workers postexposure samples, median level of urinary ETU was 8.8
(from less than 0.5 to 126.3) µg/g creatinine. This level is significantly higher than those
found in worker preexposure samples and in controls, used as reference values.
Key Words: Agricultural workers; biological monitoring; EBDTC; EBDTC production workers; ethylenethiourea; ethylenebisdithiocarbamates; ETU; gas chromatography–mass spectrometry; general population; occupational exposure in humans; urine;
vineyard workers.
1. Introduction
Ethylenebisdithiocarbamates (EBDTCs) are widely used in agriculture as fungicides, mainly on fruits, vegetables, and ornamental plants. Because of low acute toxicity and short environmental persistence, their use is increasing worldwide. The
metabolic pathway of EBDTCs in mammals is complex and gives rise to the production of several metabolites, among which is ethylenethiourea (ETU; Fig. 1) (1). ETU
can also be produced by the spontaneous degradation of EBDTCs in the treated crops
or during their production, formulation, and storage (2,3). Although the acute toxicity
of EBDTCs and ETU is low, possible long-term effects consequent to low-dose prolonged exposures have not been fully elucidated yet (4,5).
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
79
80
Fustinoni et al.
Fig. 1. Molecular structure of ETU.
Human occupational exposure to EBDTCs or ETU takes place in industrial settings
and in agriculture. The general population may be exposed through the ingestion of
contaminated food and water (6,7). To assess this exposure, the determination of urinary ETU is proposed (8–13), and here is reported a sensitive analytical method suitable for this aim. A protocol for the biological monitoring of exposure to EBDTCs or
ETU is outlined. The results obtained by investigating a group of agricultural workers
and a group of healthy subjects belonging to the general population, chosen as controls, are reported.
2. Materials
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
ETU or 2-imidazolidinethione (>98%).
Propylenethiourea (PTU; 94%, e.g., Dr. Ehrenstofen, Ausburg, Germany).
Ethylene-d4-diamine (98%, e.g., Aldrich, Poole, UK)
Carbon disulfide (CS2; >99.5%).
Potassium hydroxide (KOH).
Ethanol (EtOH; >99.8%).
Hydrochloric acid in water (HCl; 37% w/v).
Acetone (>99.8%).
Silica gel for flash chromatography (200–400 mesh).
Methanol (MeOH; >99.9%).
Ammonium chloride (NH4Cl; >99%).
Potassium fluoride (KF; >99%).
Dichloromethane (>99.9%).
Water (high-performance liquid chromatographic grade).
Derivatization mixture: anhydrous acetonitrile, N-(tert-butyldimethylsilyl)-N-methyltrifluoroacetamide (BSTFA; derivatization grade in glass-sealed ampoule, e.g. Aldrich),
and tert-butyldimethylsilyl chloride (t-BuMe2Si-Cl; >97%) at the ratio 5:4:1 v/v/v.
Anhydrous acetonitrile: acetonitrile (CH3CN; >99.9%) on molecular sieve (1.6-mm pellets, 4-Å pore).
Silica gel thin-layer chromatographic plates, 60-Å F254 with fluorescent indicator 250µm layer thickness (e.g., Merck, Darmstadt, Germany).
Iodine (I2; 99.8%).
3-mL diatomaceous earth column (e.g., Chem Elut 1003, Varian, Sunnyvale, CA).
Picric acid in water (1% w/v).
Sodium hydroxide in water (NaOH; 2.5M).
Determination of Urinary ETU
81
22. Chromatographic column CPSil 19 CB, 30 m long, 0.25 mm id, 0.25-µm film thickness
(e.g., Varian).
23. Gas chromatograph equipped with split–splitless injector operating in the splitless mode
and a mass detector operating in the electron impact (EI) mode.
3. Methods
The method described below outlines (1) the preparation of ethylenethiourea-d4
(ETU-d4) for use as an internal standard; (2) the chromatographic method for the
determination of ETU in human urine; (3) a protocol suitable for the field studies with
typical levels of ETU excreted in Italian vineyard workers and general population.
3.1. Ethylenethiourea-d4
The synthesis, purification, and characterization of ETU-d4 used as an internal standard in the determination of urinary ETU are described in Subheadings 3.1.1.–3.1.3.,
respectively.
3.1.1. Synthesis
Prepare ETU-d4 accordingly to a previous publication, with some modification (14).
Briefly, introduce ethylene-d4-diamine (135 µL, 2 mmol) in a two-neck flask containing 300 µL H2O. Add a solution of KOH (225 mg, 2 mmol) in H2O (300 µL) and heat
the mixture at 40°C for 20 min. Cool the solution at room temperature and add EtOH
(600 µL) and CS2 (300 µL, 5 mmol). Reflux the reaction mixture at 60°C for 45 min
and then at 100°C for 30 min. Cool the reaction mixture at room temperature again,
add aqueous HCl (300 µL), then heat at 100°C for 7 h. Finally, cool the reaction mixture overnight at room temperature to obtain a whitish solid. Filter the solid and wash
it with few milliliters of cold acetone to yield raw ETU-d4 purified as described below.
3.1.2. Purification
Purify the raw product by flash chromatography. Fill a glass column (50 cm long, 2
cm id) with 200–400 mesh silica gel to obtain a 20-cm dry bed. Prepare about 500 mL
of a mixture of dichloromethane:methanol (95:5 v/v) to use as eluting solvent. Condition the column by passing the eluting solvent through the bed until it is uniformly wet
and free of air bubbles. To speed up the operation and to obtain better packing, pump
air at the top of the column using a manual pump. Load raw ETU-d4 dissolved in a
minimum amount of eluting solvent (about 5 mL) at the top of the silica bed (see Note
1). Elute ETU-d4 with the eluting mixture and collect single fractions (about 7 mL
each) in glass tubes using the manual pump. Check the chromatographic fractions for
the presence of ETU-d4 using silica gel thin-layer chromatography plates (see Subheading 3.1.3.). Pool the appropriate fractions and evaporate the solvent under vacuum
to obtain chromatographically pure ETU-d4 (>99%) as a white solid.
3.1.3. Characterization
Perform characterization of ETU-d4 by thin-layer chromatography and GC–mass
spectrometry (MS). For thin-layer chromatography characterization, use silica gel
plates and elute ETU-d4 vs ETU with the dichloromethane:methanol 95:5 mixture.
82
Fustinoni et al.
Develop the chemicals as yellow-brown spots in the presence of I2 vapors. In this
condition, ETU and ETU-d4 show a retention index of about 0.3. For the GC–MS
characterization, react a solution of ETU-d4 in anhydrous acetonitrile (1 mg/mL) with
100 µL of derivatization mixture at 60°C for 30 min. Analyze the reaction mixture by
GC–MS using the eluting conditions described in Subheading 3.2.2. For peak detection, select the dynamic range m/z 40–400 and acquire the mass spectra in the full-scan
mode. Under this condition, a chromatogram with three peaks, corresponding to the
unreacted ETU-d4 (tr = 5.60 min), the monosilanized derivative (t-BuMe2Si)-ETU-d4
(tr = 6.24 min), and the bis-silanized derivative bis(t-BuMe2Si)-ETU-d4 (tr = 6.46
min), is obtained. The principal peak ions in the mass spectra are as follows:
ETU-d4: m/z 106 [M]+• (100%) (for mass spectra, see Fig. 2)
(t-BuMe2Si)-ETU-d4: m/z 220 [M]+• (4%), 163 [M+•–C(CH3)3•]+ (100%), 205 [M+•–CH3•]+ (4%)
bis(t-BuMe2Si)-ETU-d4: m/z 334 [M]+• (0.5%), 277 [M+•–C(CH3)3•]+ (100%), 319 [M+•–CH3•]+ (7%).
3.2. Determination of Urinary ETU
The extraction of ETU from urine and its derivatization, the gas chromatography–
mass spectrometry (GC–MS) analysis of the derivative, the preparation of the solutions for the calibration curve, the preparation of the internal standard solution, and
the calculation of urinary ETU concentration are described in Subheadings 3.2.1.–
3.2.5. Subheading 3.2.6. describes the determination of urinary creatinine.
3.2.1. Extraction and Derivatization of ETU
Leave urine samples at room temperature until completely thawed. Mix the sample,
wait a few minutes, then transfer 3 mL of the specimen’s supernatant (see Note 2) in a
glass vial containing 0.1 g NH4Cl and 1.5 g KF (see Note 3). Add 0.1 mL of internal
standard solution to the final concentration of 83.3 µg/L of ETU-d4 in urine (see Note
4). Vigorously stir the mixture to facilitate dissolution of salts and pour the solution
onto a diatomaceous earth column (see Note 5). After urine percolation (about 5 min),
add 12 mL dichloromethane through the column and collect the organic solvent in a
20-mL glass vial. Evaporate the extract at 25–35°C using a stream of nitrogen. Dissolve the residue with 1 mL dichloromethane (0.5 mL × 2) and transfer the solution in
a 1.8-mL glass vial. Gently evaporate the solvent at 25–35°C using a stream of nitrogen and add the residue with 0.1 mL of derivatization mixture (see Note 6). Seal the
vial with a plastic screw cap lined with polyperfluoroethylene gasket and react the
mixture at 60°C overnight. Under these conditions ETU and ETU-d4 react to give the
bis-silanized derivatives bis(t-BuMe2Si)-ETU and bis(t-BuMe2Si)-ETU-d4 (see Note
7). Transfer the residue, cooled at room temperature, in a conical insert and analyze it
as described below.
3.2.2. Gas Chromatography–Mass Spectrometry
Inject 1 µL of the derivatized mixture containing bis(t-BuMe2Si)-ETU and bis(tBuMe2Si)-ETU-d4 in acetonitrile into the chromatographic column through the injector liner kept at 250°C. Use helium as a carrier gas at constant flow of 1 mL/min. Keep
the oven temperature at 150°C for 1 min, then increase the temperature to 240°C at the
rate of 20°C/min. Finally, keep the oven at 240°C for 5 min. Under these conditions,
Determination of Urinary ETU
83
83
Fig. 2. Mass spectra of ETU-d4 acquired in the EI mode.
84
Fustinoni et al.
the ETU and ETU-d4 derivatives [bis(t-BuMe2Si)-ETU and bis(t-BuMe2Si)-ETU-d4]
are eluted. The total run time is 10.5 min.
Set the MS detector with the electron impact (EI) source (70 eV) kept at 230°C in
the selected ion monitoring (SIM) mode. Select a 4-min delay time and 100-ms dwell
time. From 4 to 9 min, focus the spectrometer at ions m/z 273 and 277 [M+.–C(CH3)3.]+
for bis(t-BuMe2Si)-ETU and bis(t-BuMe2Si)-ETU-d4, respectively. Under the described conditions, approximate retention time for both bis(t-BuMe2Si)-ETU and bis(tBuMe2Si)-ETU-d4 is 6.42 min (see Fig. 3).
3.2.3. Preparation of the Calibration Solutions
Use calibration solutions of ETU in urine at concentrations of 200, 100, 50, 25,
12.5, and 2.5 µg/L to obtain the calibration curve. Prepare the calibration solutions for
dilution of an aqueous ETU solution at the initial concentration of 10 mg/L with a pool
of urine obtained from nonsmoking, nonoccupationally exposed donors. Use an
unspiked sample of the same urine as blank. Divide the calibration solution and the
urine blank in small portions (about 10 mL) and store at −20°C in the dark. In these
conditions, the solutions are stable for at least 6 mo.
3.2.4. Preparation of Internal Standard Solution
Prepare the internal standard solution by diluting ETU-d4 in water at the concentration of 2.5 mg/L. The internal standard solution, stored at −20°C in the dark, is stable
for at least 6 mo.
3.2.5. Calibration Curve and Calculation
Obtain the calibration curve analyzing the above-mentioned calibration solutions
in the presence of ETU-d4 as an internal standard following the procedure of extraction, derivatization, and analysis outlined in Subheadings 3.2.1. and 3.2.2. Use the
least-square linear regression analysis to calculate the slope m of the function Y = mX,
where Y is the ratio between the chromatographic peak area of bis(t-BuMe2Si)-ETU
and bis(t-BuMe2Si)-ETU-d4 at the different concentrations subtracted by the same ratio in the blank, and X is the ETU concentration (see Note 8).
Use the calibration curve to calculate the ETU concentration in unknown urine
samples. Divide the ETU concentration, expressed in micrograms per liter, by urinary
creatinine concentration, expressed as grams creatinine per liter and determined as
described in Subheading 3.2.6., to obtain the ETU concentration expressed as micrograms per gram creatinine (see Note 9). The limit of detection for the entire assay is
0.5 µg/g creatinine (see Note 10).
3.2.6. Urinary Creatinine
Determine the concentration of urinary creatinine by Jaffe’s colorimetric assay. In
brief, react 20 µL urine with 5 mL aqueous solution of picric acid (1% w/v) in NaOH
(2.5 M). Wait 10 min and read the absorption of the complex creatinine–picrate at 512
nm using an ultraviolet–visible (UV–Vis) spectrophotometer.
Determination of Urinary ETU
85
85
Fig. 3. The typical chromatogram of the calibration solution with 25 µg/L ETU in urine registering the single ions m/z 273 (top) and 277
(bottom) for ETU and ETU-d4 derivatives, respectively.
86
Fustinoni et al.
3.3. Biological Monitoring of Exposure Through the Determination
of Urinary ETU
A protocol suitable for the biological monitoring of exposure through the measurement of urinary ETU is provided. Sampling strategy, sample handling, and delivery
and storage conditions are outlined in Subheadings 3.3.1. and 3.3.2. In Subheading
3.3.3., an example of field study with urinary ETU levels measured in agricultural
workers and in the general population and suggestions for the interpretation of results
are given.
3.3.1. Sampling Strategy
3.3.1.1. WORKERS
To perform the field study in subjects exposed to several active ingredients, typically agricultural workers, carefully consider the scheduled applications and select a
period in which only EBDTCs are used or multiple exposures are minimized.
Submit a personal questionnaire to gather general information (e.g., health status,
gender, age, race) and specific information concerning work (e.g., job title and
description, name and amount of pesticide formulation handled, time and kind of
exposure, use of protective devices).
Choose the best time for urine collection based on the pattern of exposure over
time: continuous (typical for industrial workers) or intermittent (typical for agricultural workers).
For preexposure sampling (see Note 11) for industrial workers, collect a spot urine
sample before shift the first working day after the weekend or a rest period. For agricultural workers, collect a spot urine sample before the seasonal applications. Preferentially collect the second urine of the morning (see Note 12) (15).
For postexposure sampling for industrial workers, collect a spot urine sample at the
end of the shift or prior to the next shift (preferentially the second urine of the morning). For agricultural workers, collect a spot urine sample at the end of the exposure or
the day after, prior to the next shift (see Note 13). When a significant variation in
exposure levels is anticipated among different working days, repeat specimen collection.
3.3.1.2. CONTROLS
Select controls among the general population without known exposure to EBDTCs/
ETU matched with workers for health status, age, gender, race, and geographical area
(see Note 11). For these subjects, assuming constant low-level exposure because of
traces of EBDTCs or ETU ingested with diet, the sampling period is not critical; however, to achieve a better comparison with workers, choose the seasonal period in which
the field study is performed.
For control sampling, collect a spot urine sample. To achieve a better comparison,
choose the same moment used for the collection of worker’s specimens.
3.3.2. Sample Handling, Delivery, and Storage
Pour a urine sample (10–13 mL) in a plastic tube equipped with a plastic screw cap
suitable for cryo storage. Leave some empty space in the tube (see Note 14). Label the
tube with an identification number using a water-resistant pen or a water-resistant
Determination of Urinary ETU
87
Table 1
Summary of Statistics for Urinary ETU Excretion in 47 Vineyard Workers
(Pre- and Postexposure Samples) and in 33 Controls
Urinary ETU (µg/g creatinine)
Subjects (N)
Sampling time
Mean
SD
Median
Vineyard
workers (47)
Controls (33)
Preexposure
Postexposure
—
1.3
21.5
1.7
1.9
29.8
2.2
<0.5a
8.8
0.9
a0.5
Minimum
<0.5
<0.5
<0.5
Maximum
8.2
126.3
11.6
µg/g creatinine is the detection limit of the assay.
adhesive label. Shield the tube from light with aluminum foil (see Note 15). Refrigerate the sample at 4°C as soon as possible and deliver it chilled to the laboratory within
24 h of sampling. If the delivery is delayed, store urine at −20°C. ETU in a specimen
kept a −20°C in the dark is stable for at least 6 mo.
3.3.3. The Field Study: An Example
Table 1 indicates the urinary ETU levels measured by applying the protocol to 47
agricultural workers exposed to EBDTCs in the vineyards during mixing, loading,
application, and reentry and 33 controls. Regard the ETU concentration in preexposure
specimens as an internal reference level for workers. Moreover, regard the ETU concentration in controls as a local reference value (see Note 11). Compare the ETU concentration determined in workers’ postexposure specimens with the reference values.
The comparison shows significant EBDTCs exposure in the investigated vineyard
workers. Furthermore, the ETU levels found in the absence of occupational exposure
confirm a slight ubiquitous exposure to EBDTCs/ETU presumably attributable to diet.
Finally, because of the absence of biological exposure indices for urinary ETU, no
conclusion can be drawn regarding the health risk associated with this exposure. However, all the workers studied were in good health and had no sign of health impairment
attributable to exposure.
4. Notes
1. In this condition, part of the raw ETU-d4 may not dissolve because of the presence of
inorganic salts. Load the dissolved fraction on the chromatographic column.
2. Take only the urine supernatant to avoid loading sediment onto the liquid–liquid extraction column.
3. Add NH4Cl to adjust the pH. Add KF to increase ion strength and facilitate liquid–liquid
extraction of ETU. KF is highly hydroscopic, so quickly weigh it and keep it in a closed
vial before use.
4. The use of PTU as an internal standard for the determination of urinary ETU has been
alternatively investigated. The performances of the entire procedure regarding linearity,
repeatability, and sensitivity were similar to those obtained using ETU-d4. Major differences were in the registration of single-ion m/z 287 for the internal standard derivative of
PTU and in its retention time, which is 6.27 min under the chromatographic conditions
described in Subheading 3.2.2. The advantage of using PTU instead of ETU-d4 is that the
former is commercially available. A major drawback is that PTU is itself the metabolite
88
Fustinoni et al.
of pesticides such as Propineb, so it may not be employed if this exposure takes place.
5. Vigorously stir the mixture as soon as possible to avoid the formation of clots.
6. Prepare the derivatization mixture daily. Preferentially, purchase the derivatization
reagent BSTFA in small glass-sealed ampules.
7. The kinetic of the derivatization of ETU to form the bis(t-BuMe2Si)-ETU derivative is
slow, and the reaction is not completed under the conditions described in the present
assay. In fact, from each reactant two major chemicals are formed: the mono- and the bistBuMe2 derivatives in a ratio of about 1:1. To complete the formation of bis(t-BuMe2Si)ETU, more than 60 h are required. This is a long time, and 16 h or overnight is chosen
instead for convenience. Nevertheless, this procedure provides good results because the
assay is performed in the presence of the internal standard, which ensures that the analytevs-internal standard signal ratio is constant over a wide range of time (i.e., from 5 to 60
h). Of course, higher sensitivity could be achieved if the complete conversion to bistBuMe2 derivative was performed.
8. The linearity of the regression curve is good over the entire investigated range, with a
correlation coefficient typically higher than 0.99. The repeatability of the assay, as coefficient of variation percentage, at a urinary ETU concentration of 25 µg/L, is <5%.
9. In a healthy adult, the daily urine volume may vary substantially (from 600 to 2500 mL).
Therefore, urine dilution may be a significant confounding factor in the determination of
ETU in a spot urine sample. In particular, this is the case for agricultural workers, who
often perform difficult jobs in the presence of such adverse weather conditions as high
temperature or humidity. Moreover, the activity of the kidney in the excretion of
xenobiotics or their metabolites is not constant during the day. An obvious, but not a
practical, solution would be the collection of a 24-h urine sample. A more popular approach, which we also propose for the determination of urinary ETU, is the correction for
creatinine. Creatinine in urine (normal values range from 0.3 to 3.4 g/L) is both an indicator of urine dilution and an index of kidney activity. Support for the use of creatinine for
the correction of ETU excretion is the similarity between the two molecules, so that an
analogous mechanism of kidney excretion may be postulated.
10. An analytical limit of detection of 0.6 µg/L is calculated as five times the signal obtained
by submitting a water sample to the procedure of extraction, derivatization, and analysis
outlined in Subheadings 3.2.1. and 3.2.2. The limit of detection of the assay of 0.5 µg/g
creatinine is estimated by dividing the analytical limit of detection by the mean level of
creatinine excreted in healthy subjects (1.2 g creatinine/L).
11. The collection of a preexposure urine sample in workers and of urine sample in controls
allows us to obtain ETU levels in the absence of occupational exposure to be used as
internal and local reference values, respectively. Because of the lack of biological exposure indices, these values are necessary terms of reference for the comparison with urinary ETU levels in workers’ postexposure samples.
12. For practical purposes, we suggest the collection of the second urine of the morning (15).
From workers, this specimen is easily obtained just before the beginning of the shift. For
controls, we suggest the same sampling time to achieve a better comparison with workers.
13. To better define the best time for sample collection, we performed a study to investigate
the kinetic of urinary ETU excretion in agricultural workers. The results of this study
showed that the ETU levels in urine collected at the end of the exposure or prior to the
next shift (about 16 h after the end of exposure) are comparable (unpublished results).
14. Space is left in the tube to compensate for expansion of urine volume caused by freezing.
15. Aluminum foil shields the tube from light to avoid photodegradation of ETU (16).
Determination of Urinary ETU
89
References
1. Somerville, L. (1986) The metabolism of fungicides. Xenobiotica 16, 1017–1030.
2. Blazquez, C. H. (1973) Residue determination of ethylene-thiourea (2-imidazolidinethione) from tomato foliage, soil, and water. J. Agric. Food Chem. 21, 330–332.
3. Bontoyan, W. R., Looker, J. B., Kaiser, T. E., Giang, P., and Olive, B. M. (1972) Survey
of ethylenethiourea in commercial ethylenebis-dithiocarbamate formulations. J. AOAC
Int. 55, 923–925.
4. Houeto, P., Bindoula, G., and Hoffman, J. R. (1995) Ethylenebisdithiocarbamate and
ethylenethiourea: possible human health hazards. Environ. Health Perspect. 103, 568–573.
5. International Agency for Research on Cancer. (2001) Monographs, vol. 79, Some Thyrotropic Agents. IARC, Lyon, France, pp. 659–701.
6. Newsome, W. H. (1976) Residues of four ethylenebisdiocarbammate and their decomposition products on field-sprayed tomatoes. J. Agric. Food Chem. 24, 999–1001.
7. Nitz, S., Moza, P. N., Kokabi, J., Freitag, D., Behechti, A., and Kote, F. (1984) Fate of
ethylenebis(dithiocarbamates) and their metabolites during the brew process. J. Agric.
Food Chem. 32, 600–603.
8. Aprea, C., Sciarra, G., and Sartorelli, P. (1998) Environmental and biological monitoring
of exposure to mancozeb, ethylenethiourea, and dimethoate during industrial formulation.
J. Toxicol. Environ. Health A 53, 263–281.
9. Aprea, C., Betta, A., Catenacci, G., et al. (1996) Reference values of urinary ethylenethiourea
in four regions of Italy (multicentric study). Sci. Total Environ. 192, 83–93.
10. Aprea, C., Betta, A., Catenacci, G., et al. (1997) Urinary excretion of ethylenethiourea in
five volunteers on a controlled diet (multicentric study). Sci. Total Environ. 203, 167–179.
11. Canossa, E., Angiuli, G., Garasto, G., Buzzoni, A., and De Rosa, E. (1993) Indicatori di
dose in agricoltori esposti a mancozeb. Med. Lav. 84, 42–50.
12. Colosio, C., Fustinoni, S., Birindelli, S., et al. (2002) Ethylenethiourea in urine as an indicator of exposure to mancozeb in vineyard workers. Toxicol. Lett. 134, 133–140.
13. Kurttio, P., and Savolainen, K. (1990) Ethylenethiourea in air and urine as an indicator
of exposure to ethylenebisdiocarbammate fungicides. Scan. J. Work Environ. Health 16,
203–207.
14. Doerge, D. R., Cooray, N. M., Yee, A. B. K., and Niemczura, W. P. (1989) Synthesis of
isotopically-labelled ethylenethiourea. J. Label. Comp. Radiopharm. 28, 739–742.
15. Hoet, P. (1996) Biological Monitoring of Chemical Exposure in the Workplace. World
Health Organization, Geneva, pp. 1–19.
16. Ross, R. D., and Crosby, D. G. (1973) Photolysis of ethylenethiourea. J. Agric. Food
Chem. 21, 335–337.
2,4-D and MCPA in Human Urine
91
7
Analysis of 2,4-Dichlorophenoxyacetic Acid
and 2-Methyl-4-Chloro-Phenoxyacetic Acid in Human Urine
Cristina Aprea, Gianfranco Sciarra, Nanda Bozzi, and Liana Lunghini
Summary
Two methods for the quantitative analysis of 2,4-dichlorophenoxyacetic acid (2,4-D)
and 2-methyl-4-chlorophenoxyacetic acid (MCPA) in urine are reported. Hydrochloric
acid, sodium chloride, and internal standards (2,3-dichlorophenoxyacetic acid [2,3-D] or
4-chlorophenoxyacetic acid [4-CPA]) are added to the urine. The mixture is extracted
with dichloromethane. For the high-performance liquid chromatographic (HPLC)
method, the concentrated extract is drawn into a previously conditioned silica cartridge
in which 2,4-D and MCPA are enriched. For the gas chromatographic (GC) method,
after extraction the two compounds are converted to their pentafluorobenzyl esters and
purified in a previously conditioned silica cartridge. Calibration is carried out using standard solutions in urine, which are processed in the same way as the urine samples and are
determined by HPLC with diode array detector (DAD) or GC with electron capture detection (ECD). The peak areas of the chlorophenoxycarboxylic acids obtained are divided by the peak areas of the respective internal standard. The resulting quotients are
plotted as a function of the concentration of the chlorophenoxycarboxylic acids to obtain
a calibration curve. The two methods have detection limits of about 15 µg/L and 1 µg/L
for 2,4-D and MCPA, respectively.
Key Words: Chlorophenoxycarboxylic acids; general population; GC analysis; herbicides; HPLC analysis; occupational exposure; pentafluorobenzylbromide
derivatization.
1. Introduction
2,4-Dichlorophenoxyacetic acid (2,4-D) and 2-methyl-4-chlorophenoxyacetic acid
(MCPA) are selective, hormone-type pesticides widely used as postemergence herbicides to eliminate weeds from cereal and grass crops.
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
91
92
Aprea et al.
Intake of 2,4-D and MCPA may occur by inhalation, ingestion, or absorption
through intact skin. In humans, the two compounds are mainly eliminated unchanged
by urinary excretion. A small proportion of conjugates has been detected in a few
cases (1–3). Urinary levels of 2,4-D and MCPA as free acids can therefore be used as
indicators of exposure to these compounds and their salts (4).
Exposure to mixtures of phenoxyacetic, chlorophenol, and chlorinated
dibenzodioxin herbicides seems to be associated with an increase in the incidence of
malignant lymphoma and sarcoma of the soft tissues (5). Because many tumors have
been associated with exposure to phenoxy herbicides and their contaminants or other
chemical compounds, it is uncertain whether exposure to 2,4-D and MCPA is specifically related to the development of sarcoma of the soft tissues.
Because of widespread use, principally of 2,4-D, methods are required to monitor
exposure of workers and the general population. Various methods of determining 2,4D and MCPA in urine have been developed. High-performance liquid chromatographic
(HPLC) procedures (1,6,7) involve assay of nonderivatized acids but have quite high
detection limits. The high polarity of these compounds makes it impracticable to analyze them directly by gas chromatography (GC), and they must first be derivatized to
stable and more volatile compounds. The derivatives most commonly prepared are
alkyl esters: methylation with dimethylsulfate was proposed by Vural and Burgaz (8);
other authors have used diazomethane (9,10) and diazoethane (11). Pentafluorobenzylbromide is another derivatizing agent used to increase the response of
electron capture detectors (ECDs) in GC analysis of the two herbicides (12). These
procedures rarely have detection limits below 20–30 µg/L, except those of Holler et
al. (11) and Hughes et al. (10), which have limits of 1 µg/L and 5 µg/L, respectively. A
radioimmunoassay method with a detection limit of 1 µg/L was used for the analysis
of 2,4-D in urine (13,14).
The two methods described here enable simple and reliable determination of 2,4-D
and MCPA in urine using HPLC with diode array detection (DAD) and GC with ECD.
The excellent reproducibility, recovery, and operational simplicity of the methods
make them suitable for routine use in most laboratories. The detection limit of 15 µg/
L means that the HPLC method can be used to determine 2,4-D and MCPA in occupationally exposed subjects. The GC method with a detection limit of 1 µg/L can also be
used to assay the two compounds in the general population. The GC method and the
HPLC method are equivalent for determining 2,4-D and MCPA in urine of occupationally exposed subjects (15).
2. Materials
2.1. Equipment
1. Apparatus for sample evaporation (e.g., rotating evaporator with water bath or automated
system for several samples).
2. Apparatus for Ultrapure water production (e.g., Milli-RO/Milli Q system, Millipore,
Bedford, MA).
3. Workstation for vacuum extraction (e.g., Supelco, Bellefonte, PA) or automated system
(e.g., Gilson, OH).
2,4-D and MCPA in Human Urine
93
4. Vortex mixer.
5. Equipment for liquid–liquid extraction, preferably mechanical automated system for several samples.
6. Centrifuge.
7. Solid-phase extraction (SPE) silica cartridges (3-mL column reservoir, 500 mg sorbent)
(e.g., Supelco).
8. Sampler vials (approx 1.5 mL) with crimp caps and crimping tongs.
9. 10-, 100-, 1000-mL volumetric flasks with a ground glass stopper.
10. 1-, 2-, 5-, and 10-mL glass pipets.
11. Microliter pipets, adjustable between 100 and 1000 µL (e.g., Eppendorf, Hamburg, Germany).
12. 50-mL glass vials with plastic or glass stoppers.
13. HPLC system, diode array detector (DAD) and computer software or integrator.
14. HPLC column that is LC8, 25 cm long, 4.6 mm id, 5-µm grains (e.g., Supelco).
15. Filters for samples before injection into the HPLC column (e.g., Millex HV 13, Millipore).
16. 20-µL syringe for HPLC, preferably an autosampler.
17. Gas chromatograph with split–splitless injector, ECD, and computer software or integrator.
18. GC column 50 m long, 0.32 mm id, 0.4-µm thick film; dimethyl (95%), diphenyl (5%),
polysiloxane stationary phase (e.g., CP Sil 8, Chromopack, Middleburg, The Netherlands).
19. 2-µL syringe for GC, preferably an autosampler.
2.2. Chemicals (see Note 1)
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
Pentafluorobenzylbromide (e.g., from Aldrich, Poole, UK).
Acetone.
Methanol.
n-Hexane.
Dichloromethane.
LiChrosolv-type acetonitrile.
Analytical-grade sodium chloride.
Analytical-grade anhydrous potassium carbonate.
Pure anhydrous sodium sulfate (fine powder).
Analytical-grade monobasic potassium phosphate.
Pure 85% orthophosphoric acid.
Analytical-grade 37% hydrochloric acid.
Pure 100% glacial acetic acid.
2,4-D (99.77% purity) (e.g., Dr. Ehrenstorfer, Ausburg, Germany).
MCPA (99.7% purity) (e.g., Dr. Ehrenstorfer).
2,3-Dichlorophenoxyacetic acid (2,3-D) (98.4% purity) (e.g., Dr. Ehrenstorfer).
4-Chlorophenoxyacetic acid (4-CPA) (98% purity) (e.g., Dr. Ehrenstorfer).
Ultrapure water (equivalent to ASTM type 1).
Purified nitrogen.
Helium for GC.
Argon–methane (5% methane) for GC.
2.3. Solutions
1. Internal standard solution for HPLC (see Note 2). About 10 mg 4-CPA is weighed exactly
in a 100-mL volumetric flask, which is then filled to the mark with methanol (contents
94
2.
3.
4.
5.
6.
7.
8.
Aprea et al.
100 mg/L). Of this solution, 20 mL are pipeted into a 100-mL volumetric flask, which is
then filled to the mark with Ultrapure water (contents 20 mg/L). This solution can be
stored in the refrigerator at 4°C for about 4 wk.
For the internal standard solution for GC (see Note 3), about 10 mg 2,3-D and 10 mg 4CPA are weighed exactly in a 100-mL volumetric flask, which is then filled to the mark
with methanol (contents 100 mg/L). Of this solution, 5 mL is pipeted into a 100-mL
volumetric flask, which is then filled to the mark with Ultrapure water (contents 5 mg/L).
This solution can be stored in the refrigerator at 4°C for about 4 wk.
For dichloromethane solution acidified with acetic acid, 1 mL acetic acid is diluted to 100
mL with dichloromethane in a 100-mL volumetric flask.
For pentafluorobenzylbromide solution, 100 µL pure pentafluorobenzylbromide is diluted to 10 mL with acetone in a 100-mL volumetric flask. This solution can be stored in
the refrigerator at 4°C for about 1 wk.
For potassium carbonate solution, about 6 g anhydrous potassium carbonate is weighed in
a 10-mL volumetric flask, which is then filled to the mark with Ultrapure water (content
about 60% w/v). This solution can be stored in the refrigerator at 4°C for about 4 wk.
n-Hexane/dichloromethane solution (1:70 mL), n-hexane is transferred to a 100-mL volumetric flask, which is then filled to the mark with dichloromethane. This solution must be
prepared daily.
For the n-hexane/dichloromethane solution (2:60 mL), n-hexane is transferred to a 100mL volumetric flask, which is then filled to the mark with dichloromethane. This solution
must be prepared daily.
For the phosphate buffer, 1.36 g monobasic potassium phosphate and 500 µL glacial
acetic acid are transferred to a 1000-mL volumetric flask, which is then filled to the mark
with Ultrapure water. The pH is adjusted to 3.2 by adding a few drops of orthophosphoric
acid. This solution must be prepared daily.
2.4. Calibration Standards
2.4.1. Starting Solution
About 10 mg 2,4-D and 10 mg MCPA are weighed exactly in a 10-mL volumetric
flask, which is then filled to the mark with methanol (content 1 mg/mL). This solution
can be stored in the refrigerator at 4°C for about 4 wk.
2.4.2. Stock Solution
For the stock solution, 2 mL of the starting solution is pipeted into a 10-mL volumetric flask, which is then filled to the mark with Ultrapure water (contents 200 µg/
mL). This solution can be stored in the refrigerator at 4°C or about 4 wk.
2.4.3. Working Solutions
Working solutions (WSs) to construct calibration curves in urine are prepared from
stock solution by diluting with Ultrapure water. They contain between 0.78 and 100
mg chlorophenoxycarboxylic acid per milliliter (Table 1). These solutions are prepared daily.
2,4-D and MCPA in Human Urine
95
Table 1
Scheme for the Preparation of the WSs
Identification of the
working solution
Volume of stock
solution or WS
WS1
WS2
WS3
WS4
WS5
WS6
WS7
WS8
5 of the stock solution
5 of the WS1
5 of the WS2
5 of the WS3
5 of the WS4
5 of the WS5
5 of the WS6
5 of the WS7
Final volume of
working solutions
(mL)
10
10
10
10
10
10
10
10
Concentration of WS
(µg/mL)
100
50
25
12.5
6.25
3.125
1.5625
0.78125
2.5. Preparation of Silica Cartridges
2.5.1. HPLC Method
A silica cartridge is conditioned with 6 mL dichloromethane. The prepared cartridge must still be moist when the sample is introduced.
2.5.2. GC Method
A silica cartridge is conditioned with 3 mL dichloromethane and 6 mL n-hexane in
that order. The prepared cartridge must still be moist when the sample is introduced.
2.6. Specimen Collection
Specimens are collected in sealable plastic bottles without preservatives or stabilizers.
3. Methods
3.1. Sample Preparation
A 20-mL urine sample, transferred to a 50-mL glass vial, is spiked with 400 µL
internal standard solution (4-CPA solution for HPLC and 4-CPA/2,3-D solution for
GC), 200 µL concentrated HCl, and about 4 g sodium chloride (saturation of sample)
(see Note 4). Thus prepared, the vial is sealed with a plastic or glass stopper, and the
urine sample is extracted twice with 12 mL dichloromethane. Each extraction step
lasts 10 min and is followed by centrifugation at 2100g for 5 min. For sample preparation by liquid–liquid extraction, it is convenient to use equipment that can mechanically extract several urine samples at the same time.
The organic extracts are pooled in a new 50-mL glass vial, dehydrated with anhydrous sodium sulfate, and evaporated to dryness in a rotating vacuum evaporator at
30°C or in an automated system designed to process several samples at the same time.
96
Aprea et al.
3.1.1. HPLC Method (see Note 5)
After liquid–liquid extraction, the residue, made up with 1 mL dichloromethane
solution acidified with acetic acid, is slowly drawn through the silica cartridge prepared as described and still moist. The eluate is not collected. The column is rinsed
with 1 mL dichloromethane solution acidified with acetic acid, and the eluate is collected with the subsequent 3 mL of dichloromethane. Only at this point is the cartridge
sucked dry. The organic phase obtained is evaporated to dryness under a gentle nitrogen stream. The residue is made up with 0.5 mL methanol and filtered in a sampler
vial (approx 1.5 mL). After the vial is sealed with a crimp cap, the sample is injected
into the HPLC column. For sample preparation by liquid–solid extraction, it is convenient to use equipment that can handle several cartridges at the same time.
3.1.2. GC Method (see Note 6)
After liquid–liquid extraction, the residue is spiked with 200 µL pentafluorobenzylbromide solution, 15 µL potassium carbonate solution, and 4 mL acetone. The mixture
is shaken in a vortex mixer and left to react at ambient temperature for at least 5 h (the time
for maximum reaction yield is 5 h, but no changes or degradation occur after that time).
After the reaction, 3 mL Ultrapure water and 10 mL dichloromethane are added.
The mixture is shaken for 5 min in a mechanical shaker and then centrifuged at 1369g
for 5 min. The organic phase is transferred to a new 50-mL glass vial, dried on anhydrous sodium sulfate, and evaporated to dryness in a rotating vacuum evaporator at
30°C or in an automated system equipped to process several samples at the same time.
The residue, made up with 1 mL hexane, is drawn slowly through the silica cartridge,
prepared as described and still moist. The eluate is not collected. The column is rinsed
with 2 mL n-hexane/dichloromethane solution 1 (the eluate is not collected) and then
eluted with 4 mL n-hexane/dichloromethane solution 2. Only at this point is the cartridge sucked dry. The organic phase is evaporated to about 0.5 mL under a gentle
nitrogen stream and transferred to a sampler vial (approx 1.5 mL). Once the vial is
sealed with a crimp cap, the sample is injected into the gas chromatograph (see Note
7). For sample preparation by liquid–solid extraction, it is convenient to use equipment that can deal with several cartridges at the same time.
3.2. Operational Parameters for HPLC
Mobile phase acetonitrile/phosphate buffer with the elution gradient are reported in
Table 2. Elution flow is 2 mL/min; 10-µL injection volume; 30°C column temperature; and 230-nm detector wavelength. Under these conditions, retention times are
about 6 min for 4-CPA (internal standard), about 13 min for 2,4-D, and about 14 min
for MCPA.
3.3. Operational Parameters for GC (see Note 8)
Detector temperature is 300°C; for carrier gas, the flow rate is 0.6 mL/min, and
linear velocity is 27.9 cm/s. Make-up gas flow rate is 65 mL/min. Injection volume is
1 µL by the splitless technique (splitless time 1 min). Injector temperature is 250°C.
2,4-D and MCPA in Human Urine
97
Table 2
Elution Gradient for HPLC Analysis
Step
Equilibrium
1
2
3
% Acetonitrile
% Phosphate buffer
25
25
33
25
75
75
67
75
Time (min)
10
5
Ramp 7, hold 5
Ramp 3
Table 3
Column Temperature Program for GC Analysis
Step
Equilibrium
1
2
Temperature
Time (min)
50
50
270
2
1
Ramp 35°C/min, hold 30
The column temperature program is reported in Table 3. Under these conditions, retention times are about 22 min for 4-CPA (internal standard), about 24 min for MCPA,
about 26 min for 2,4-D, and about 27 min for 2,3-D (internal standard).
3.4. Calibration
2,4-D and MCPA are determined by urine calibration curves constructed by adding
100 µL of all WSs to 20-mL aliquots of urine pooled from subjects not occupationally
exposed to chlorophenoxycarboxylic acids. A blank of the same urine (not spiked with
standard 2,4-D or MCPA) is also prepared. The additions are in the range 0.78 to 10 µg
for each of the two compounds in 20-mL urine. The concentrations of 2,4-D and MCPA
in urine are reported in Table 4.
The UCSs (urine calibration standards) are processed in the same way as the urine
samples (HPLC method or GC method) and analyzed as described by GC or HPLC. A
calibration curve is obtained by plotting the quotient of peak areas of
chlorophenoxycarboxylic acids with internal standard as a function of concentration.
In the HPLC method, 4-CPA is suitable as an internal standard for the assay of 2,4-D
and MCPA. In the GC method, 4-CPA is used as the internal standard for MCPA, and
2,3-D is used for 2,4-D.
The calibration curves are linear (r > 0.990) between the detection limit and 500 µg
of chlorophenoxycarboxylic acids per liter urine.
3.5. Calculation of Analytical Result
Recorded peak areas of chlorophenoxycarboxylic acids are divided by the peak
area of the respective internal standard. The quotients thus obtained are used to read
the appropriate concentrations, in micrograms of chlorophenoxycarboxylic acids per
liter of urine, from the calibration curve. It may be necessary to take a reagent blank
98
Aprea et al.
Table 4
Scheme for the Preparation of the UCSs
Identification of the
standard solution
Blank
UCS1
UCS2
UCS3
UCS4
UCS5
UCS6
UCS7
UCS8
Volume of the WS
(µL)
Volume of urine
(mL)
—
100 of WS8
100 of WS7
100 of WS6
100 of WS5
100 of WS4
100 of WS3
100 of WS2
100 of WS1
20
20
20
20
20
20
20
20
20
Concentration added to
urine (µg/L)
0
3.90625
7.8125
15.625
31.25
62.5
125
250
500
value into account because the purity of chemicals varies from one manufacturer to
another and can be different from one lot to another. In addition, a reagent blank can
indicate that a contamination eventually occurred during the analysis. If the reagent
blank shows a peak that can interfere with the determination of 2,4-D or MCPA, it is
necessary to investigate for the causes or subtract the signal observed from the analytical result.
3.6. Standardization and Quality Control
To determine the precision of the methods, a sample containing a constant concentration of 2,4-D and MCPA is analyzed. As material for quality control is not commercially available, it is prepared in the laboratory by adding a defined amount of the two
chlorophenoxycarboxylic acids to urine. Aliquots of this solution can be stored in the
freezer for up to 1 yr and used for quality control. The mean expected value and tolerance range of this material is obtained in a preanalytical period (one determination of
the control material in 10 different analytical series).
3.7. Reliability of the Methods
3.7.1. Precision
To determine precision in the series, two pools of urine from subjects not occupationally exposed to 2,4-D and MCPA are spiked with WSs of the two compounds to
have concentrations of 125 µg/L (HPLC method) and 30 µg/L (GC method). Ten 20mL aliquots are obtained from each pool and analyzed by the two methods: Relative
standard deviation values between 6.2 and 6.8% in the HPLC method and between 5.5
and 8.0% (Table 5) in the GC method are easily obtained.
The day-to-day precision is evaluated on the urine pools used for determination of
precision in the series spiked with 2,4-D and MCPA. Ten 20-mL aliquots from each
pool are analyzed by the two methods on 10 different days: A relative standard deviation between 7.2 and 8.3% is found for the HPLC method and between 5.8% and 9.0%
for the GC method (Table 6).
2,4-D and MCPA in Human Urine
99
Table 5
Precision in the Series for the HPLC and GC Determination of 2,4-D
and MCPA (N = 10)
HPLC method
Compound
2,4-D
MCPA
Concentration added
(µg/L)
125
125
GC method
RSD (%)
6.2
6.8
Concentration added
(µg/L)
30
30
RSD (%)
8.0
5.5
RSD, relative standard deviation.
Table 6
Day-to-Day Precision for the HPLC and GC Determination of 2,4-D
and MCPA (N = 10)
HPLC method
Compound
2,4-D
MCPA
GC method
Concentration added
(µg/L)
RSD (%)
Concentration added
(µg/L)
RSD (%)
125
125
7.2
8.3
30
30
9.0
5.8
3.7.2. Recovery of Sample Processing
To check for losses occurring during sample preparation in the HPLC method, recovery is evaluated by comparing the results obtained analyzing the solutions used for
evaluating precision in the series with those of standard solutions in methanol at the
same concentrations without further processing. Losses caused by sample processing
are between 14.7 and 18.6% (Table 7). For the GC method, recovery is evaluated by
comparing the results obtained analyzing the solutions used for evaluating precision in
the series with those of standard solutions at the same concentrations after
pentafluorobenzylbromide derivatization but without further processing. Losses
caused by sample processing are between 5.7 and 12.9% (Table 7).
3.7.3. Detection Limit
Under these conditions of sample preparation and determination, the detection limits are 15 and 1 µg of either compound per liter of urine for the HPLC and GC methods, respectively. As no reagent blank value is detectable, the detection limits are
calculated as three times the signal-to-noise ratio.
4. Notes
1. Solvents used for sample preparation and extraction must be of the highest purity as this
varies greatly from one manufacturer to another.
100
Aprea et al.
Table 7
Recovery of Sample Processing (N = 10)
HPLC method
Compound
2,4-D
MCPA
GC method
Concentration added Mean recovery Concentration added Mean recovery
(µg/L)
(%)
(µg/L)
(%)
125
125
81.4
85.3
30
30
87.1
94.3
2. In the HPLC procedure, analysis is carried out with the addition of the internal standard
4-CPA, which is suitable for the assay of both compounds.
3. In the GC method, two internal standards, 4-CPA and 2,3-D, are used because they behave
identically to MCPA and 2,4-D, respectively, during extraction and chromatography. This
increases the reproducibility of the assay.
4. Before the procedure of extracting 2,4-D and MCPA from urine, the addition of concentrated HCl transforms the two compounds in the not-dissociated form and increases recovery in dichloromethane. Saturation of the urine with NaCl gives fast separation of
the organic phase from the aqueous phase and practically complete recovery of the—organic
solvent.
5. In the HPLC method, purification of the urine extract on an SPE silica cartridges is necessary because, without this preliminary phase, chromatograms obtained would show
much interference. Dichloromethane used as an eluant during the purification gives selective migration of the two compounds and the internal standard (4-CPA) through the
silica column, leaving behind other components of the urine extract that could interfere
with the analysis. The addition of acetic acid to dichloromethane dissolves the two
phenoxycarboxylic acids present in the residue of the urine extract and favors subsequent
extraction of the two compounds from the silica, increasing the precision of the procedure.
6. In the GC method, purification on SPE silica cartridges eliminates interference by urinary
and derivatization products. The first step of washing with a hexane/dichloromethane
(70:30) mixture eliminates certain apolar components from the samples so the eluate is
not collected. Subsequent elution with hexane/dichloromethane (60:40) enables quantitative and selective recovery of the pentafluorobenzyl esters of the two compounds and the
internal standards (2,3-D and 4-CPA), leaving the more polar components, which are not
eluted, on the silica.
7. Interference by other substances is not observed: No HPLC or gas chromatographic peak
occurred at or near the characteristic retention times of 2,4-D, MCPA and the internal
standards (4-CPA and 2,3-D) for urine samples from persons occupationally and not occupationally exposed to the two compounds. Figure 1 reports a chromatogram of a real
sample obtained with the HPLC method, and Fig. 2 is a chromatogram of another sample
obtained with the GC method.
8. A modified operating procedure is developed as an alternative to the gas chromatographic
method with ECD detection described above. Sample preparation is the same as above
but with the following changes in GC operational parameters:
2,4-D and MCPA in Human Urine
101
Fig. 1. Chromatogram of urine extract obtained by the HPLC method on a real sample containing 2,4-D and MCPA.
Capillary
column
Detector
Temperatures
Carrier gas
Splitless time
Sample volume
Retention
times; m/z
Low polarity, 30 m long, 0.25-mm id,
0.25-µm film thickness (e.g., Meridian
MDN12 from Supelco)
Mass selective detector in the selective-ion
monitoring mode; 70-eV electronic
impact; 1.20-kV detector
Injector 280°C
Interface 280°C
Column: 2 min at 50°C, then increase
7°C per minute to 250°C; 15 minutes
at the final temperature Equilibrium time 2 min
Helium
Flow rate 0.6 mL/min, linear velocity 27.9 cm/s
1 min
1 µL
4-CPA 29.44 min; 366.00
(internal standard)
MCPA 30.32 min, 141.00
2,4-D 31.51 min, 181.00
2,3-D 32.00 min, 175.00 (internal standard)
102
Aprea et al.
Fig. 2. Chromatogram of urine extract obtained by the GC method on a real sample containing 2,4-D and MCPA.
The results obtained using this modified procedure are comparable to those
achieved by the previously described method. Using negative chemical ionization with
methane gas (m/z 366 for 4-CPA, 380 for 4-CPA, 400 for 2,4-D, 400 for 2,3-D), we
obtained detection limits of about 0.1 µg/L for both 2,4-D and MCPA.
References
1. Fjellstad, P. and Wannag, A. (1977) Human urinary excretion of the herbicide 2-methylchlorophenoxyacetic acid. Scand. J. Work Environ. Health 3, 100–103.
2. Sauerhoff, M. W., Braun, W. H., Blau, G. E., and Gehering, P. J. (1977) The fate of 2,4dichlorophenoxyacetic acid (2,4 D) following oral administration to man. Toxicology 8, 8–11.
3. Kolmodin-Hedman, B., Sverker, H., Ake, S., and Malin, A. (1983) Studies on phenoxy
acid herbicides. II. Oral and dermal uptake and elimination in urine of MCPA in humans.
Arch. Toxicol. 54, 267–273.
4. Kanna, S. and Fang, S. C. (1966) Metabolism of C14-labeled 2,4-dichlorophenoxyacetic
acid in rats. J. Agric. Food Chem. 14, 500–503.
5. World Health Organization. (1984) Environmental Health Criteria 29. 2,4-Dichlorophenoxyacetic Acid (2,4-D). WHO, Geneva.
2,4-D and MCPA in Human Urine
103
6. Nidasio, G. F., Burzi, F., and Sozzé, T. (1984) Determination of 2-methyl-4chlorophenoxyacetic acid (MCPA) in urine using combined TLC and HPLC methods. G.
Ital. Med. Lav. 6, 261–264.
7. Hutta, M., Kaniansky, D., Kovalcikova, E., et al. (1995) Preparative capillary
isotachophoresis as a sample pretreatment technique for complex ionic matrices in high
performance liquid chromatography. J. Chromatogr. A 689, 123–133.
8. Vural, N. and Burgaz, S. (1984) A gas chromatographic method for determination of 2,4-D
residues in urine after occupational exposure. Bull. Environ. Contam. Toxicol. 35, 518–524.
9. Smith, A. E. and Hayden, B. J. (1979) Method for the determination of 2,4-dichlorophenoxyacetic acid residues in urine. J. Chromatogr. 171, 482–485.
10. Hughes, D. L., Ritter, D. J., and Wilson, R. D. (2001) Determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine with mass selective detection. J. Environ. Sci.
Health B36, 755–764.
11. Holler, J. S., Fast, D. F., Hill, R. H., et al. (1989) Quantification of selected herbicides and
chlorinated phenols in urine by using gas chromatography/mass spectrometry/mass spectrometry. J. Anal. Toxicol. 13, 152–157.
12. Manninen, A., Kangas, J., Klen, T., and Savolainen H. (1986) Exposure of Finnish farm
workers to phenoxy acid herbicides. Arch. Environ. Contam. Toxicol. 15, 107–111.
13. Knopp, D. and Glass, S. (1991) Biological monitoring of 2,4-dichlorophenoxyacetic
acid-exposed workers in agriculture and forestry. Int. Arch. Occup. Environ. Health 63,
329–333.
14. Knopp, D. (1994) Assessment of exposure to 2,4-dichlorophenoxyacetic acid in the chemical industry: results of a 5 year biological monitoring study. Occup. Environ. Med. 51,
152–159.
15. Aprea, C., Sciarra, G., and Bozzi, N. (1997) Analytical methods for the determination
of urinary 2,4-dichlorophenoxyacetic acid and 2-methyl-4-chlorophenoxyacetic acid in
occupationally exposed subjects and in the general population. J. Anal. Toxicol. 21,
262–267.
Determination of Herbicides by LC–MS/ESI
105
8
Determination of Herbicides in Human Urine by Liquid
Chromatography–Mass Spectrometry With Electrospray
Ionization
Isabel C. S. F. Jardim, Joseane M. Pozzebon, and Sonia C. N. Queiroz
Summary
A method for the determination of triazines (simazine, atrazine) and their metabolite
2-chloro-4,6-diamino-1,3,5-triazine by liquid chromatography–mass spectrometry with
electrospray ionization (LC–MS/ESI) in human urine is described. The method outlines
the sample preparation, which involves protein precipitation with acetonitrile and solidphase extraction using C18 cartridges, and the qualitative and quantitative chromatographic analyses. The method may be used to assess occupational exposure to triazine
herbicides following the urinary excretion of low levels of both the parent compounds
and their metabolites.
Key Words: Atrazine; 2-chloro-4,6-diamino-1,3,5-triazine; human urine; liquid chromatography–mass spectrometry with electrospray ionization; simazine; solid-phase
extraction; triazines.
1. Introduction
Occupational exposure to triazine herbicides results in urinary excretion of low
levels of both the parent compounds and their metabolites (1–6). Quantitative and
qualitative analyses require highly sensitive and specific purification and determination procedures.
The increasing use of liquid chromatographic (LC) methods for pesticide analysis
is because of their applicability in determining thermally labile compounds and polar
compounds, which require derivatization before gas chromatographic (GC) analysis
(7). The good compatibility of aqueous samples with reversed-phase liquid chromatography contributes to the fact that LC is frequently applied for analyses of environmental and biological fluid samples. Although ultraviolet (UV) detectors are the most
common choice for LC, on-line liquid chromatography with mass spectrometry (LC–
MS) is an interesting approach because conventional LC detectors can cause falseFrom: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
105
106
Jardim, Pozzebon, and Queiroz
Substituents in positions 4 and 6
R1
R2
Herbicide
2-chloro-4,6-diamino-1,3,5-triazine
(metabolite)
Simazine
Atrazine
-H
-H
-C2H5
-C2H5
-C2H5
-CH(CH3)2
Fig. 1. Chemical structures of the herbicides studied.
positive results. This technique combines the advantages of coupling the separation
power of LC to the unequivocal identification potential of MS for the determination of
pesticides in biological samples (8,9).
This work describes a method for the determination by liquid chromatography–
mass spectrometry with electrospray ionization (LC–MS/ESI) of the triazines simazine
and atrazine and their metabolite 2-chloro-4,6-diamino-1,3,5-triazine (Fig. 1), present
in human urine.
2. Materials
1. Standard grade simazine (>98%), atrazine (>97%), and the metabolite 2-chloro-4,6diamino-1,3,5-triazine (>96%).
2. Methanol, pesticide grade.
3. Acetonitrile, HPLC grade.
4. Chloroform, pesticide grade.
5. Water purified by a Milli-Q Plus System (Millipore, Bedford, MA).
6. Envi C18 Supelclean 3-mL extraction tubes (e.g., Supelco, Bellefonte, PA).
7. Urine samples. These must be kept in the freezer at –20°C until use. The samples are
stable for 15 d (see Note 1).
8. LC–MS system equipped with an injector with a 10-µL loop and a UV detector (e.g.,
Waters, Milford, MA).
9. Chromatographic column (150 × 3.9 mm id) and guard column (20 × 3.9 mm id) C18
(e.g., Waters Nova-Pak C18, 4 µm).
10. Vacuum extraction system (manifold) (e.g., Supelco).
3. Methods
The steps described below outline (1) sample preparation and (2) chromatographic analysis.
3.1. Sample Preparation
Urine samples are frozen at –20°C until use. After the urine samples are thawed,
they must be shaken for homogenization. The required volume must be sampled as
quickly as possible to avoid sedimentation of solids.
Determination of Herbicides by LC–MS/ESI
107
3.1.1. Removal of Proteins
1. Take a 2-mL volume of urine.
2. Basify the sample by addition of 200 µL of NH4OH (0.01%) (pH ∼9.0) and add 4 mL of
acetonitrile at room temperature.
3. Centrifuge the mixture (5 min, 3000g).
4. Take a 3-mL aliquot of the supernatant containing urine–acetonitrile (1:2 v/v) and dilute
with 20 mL Milli-Q water (see Note 2).
3.1.2. Cleanup Using Solid-Phase Extraction
The cleanup is made by solid-phase extraction using Envi C18 Supelclean extraction tubes (3 mL) and a vacuum extraction system (manifold). The steps that follow
are involved.
3.1.2.1. SORBENT CONDITIONING
Rinse the cartridge with 10 mL methanol and then with 5 mL Milli-Q water for equilibration. Avoid allowing the sorbent to dry; otherwise, the recovery will be decreased.
3.1.2.2. SAMPLE APPLICATION
Apply all the diluted sample (Subheading 3.1.1.) to the cartridge, under vacuum, at
a flow rate of 3 mL/min.
3.1.2.3. WASHING/REMOVAL
OF INTERFERENCES
Remove undesired matrix components by passing 5 mL Milli-Q water through the cartridge. This eluate is discarded, and the sorbent bed is then dried under vacuum for 1 min.
3.1.2.4. ELUTION AND CONCENTRATION
OF THE
SAMPLE
Wipe the delivery needles of the manifold and place labeled collection tubes under
the cartridges. With the vacuum off, add the elution solvent, 3 mL chloroform, to each
cartridge (see Note 3). Turn on vacuum and carefully open the tap of the manifold to
initiate elution of the analyte. The elution must be carried out slowly to obtain suitable
recovery of the analyte.
The organic layer is evaporated to dryness under a stream of nitrogen, and the residue is dissolved in 200 µL of acetonitrile. The preconcentration factor is fivefold because the volume applied to the cartridge corresponds to 1 mL of initial urine sample,
and the final volume is 200 µL.
3.2. Chromatographic Analysis
3.2.1. Standard Solution Preparation
Stock solutions of simazine, atrazine, and the metabolite 2-chloro-4,6-diamino1,3,5-triazine are prepared in methanol at concentrations of 100 µg/mL. Intermediate
concentrations are prepared in mobile phase at concentrations of 1000 µg/L of each
herbicide (see Note 4). These solutions are stored in the refrigerator at 4°C, at which
they are stable for at least 60 d. Further solutions at five different concentrations (5,
30, 60, 100, and 200 µg/L) of each analyte are prepared daily for construction of the
analytical curve.
108
Jardim, Pozzebon, and Queiroz
3.2.2. Spiked Samples
Because certified reference material is not available and there are insufficient
samples for intercomparison assays, method accuracy is determined using spiked
samples. Three different concentrations (40, 60, and 80 µg/mL) of each pesticide are
spiked into known volumes of pesticide-free urine (blank) to calculate recovery. After
spiking the samples, carry out procedures as in Subheadings 3.1.1. and 3.2.1.
3.2.3. Chromatographic Conditions
The mobile phase is acetonitrile:H2O (40:60 v/v) with the pH of the mobile phase
adjusted to 3.0 with 0.1% CH3COOH (see Notes 5 and 6). The mobile phase flow rate
is set at 0.3 mL/min. The column is directly coupled to the inlet of a chromatograph
with a quadrupole MS system operated using the ESI source. Measurements are carried out using the positive ESI mode. All measurements are carried out at room temperature (see Note 7).
For optimization of the MS parameters, each compound is dissolved in pH 3.0 mobile phase and injected separately. A source temperature of 150°C is used. Nitrogen is
used as both nebulizer and drying gas at flow rates of 30 and 300 L/h, respectively.
The capillary voltage is 25 V for the determination of these herbicides and their
metabolite. For identification, the instrument is operated in the total ion mode; for
quantification, acquisition is in the selected ion monitoring (SIM) mode. The selected
ions for quantification are 145, 202, and 216 for 2-chloro-4,6-diamino-1,3,5-triazine,
simazine, and atrazine, respectively (see Note 8).
3.2.4. Qualitative and Quantitative Analyses (see Note 9)
1. Inject the following sequence: solvent (mobile phase), matrix blank (urine without pesticide), standards, solvent, spiked samples (urine with spiked pesticides), and samples.
Matrix blank, spiked samples, and samples are injected after processing according to the
steps in Subheadings 3.1.1. and 3.1.2. The standards, spiked samples, and samples are all
injected in triplicate.
2. Compare the chromatograms. No peak should be detected at the retention times of the
pesticides in the chromatograms of solvent and matrix blank.
3. Determine the limit of detection (LOD) and the limit of quantification (LOQ).
4. Construct the analytical curve with the areas obtained from the chromatograms vs concentration. Linear analytical curves (r2 ⱖ 0.99) must be obtained in the range from LOQ
to 200 µg/L.
5. Calculate the recoveries by comparing the replicate responses of extracted spiked samples
with those of standards that represent 100% recovery. Recovery is calculated using the
following equation:
Recovery (%) = (Mass of analyte after extraction × 100)/Mass of analyte added
6. Calculate the precision in terms of repeatability using the results obtained from the recovery samples.
7. If peaks are detected in the chromatograms of the samples, confirm the presence of the
herbicide by comparing both retention time and the mass spectra using full-scan mode.
8. Quantify the corresponding amount of the herbicide by the external standard method using the linear equation obtained from the analytical curve.
Determination of Herbicides by LC–MS/ESI
109
4. Notes
1. The stabilities of the herbicides in urine with storage time are evaluated by monitoring
aliquots of urine having two different concentrations of simazine and atrazine (80, 150
µg/L) and submitting them to replicate freeze/thaw cycles (10). The concentrations of the
herbicides are determined after the initial thawing (zero time) and after thawing at successive prefixed times (once each week). Each concentration is compared with the mean
of the zero time (initial concentration). Degradation values of <10% are obtained over a
period of 15 d.
2. The sample is diluted to decrease solution strength before the extraction procedure.
3. The C18 Supelclean extraction tubes are eluted with methanol and compared with those
eluted with chloroform. Recovery is generally good for both solvent systems, but backgrounds are cleaner using chloroform. The evaporation time for chloroform eluate is also
shorter than that for methanol. Therefore, the use of chloroform as an elution solvent is
recommended for the triazines under study.
4. An analytical curve prepared using mobile phase as solvent is preferable for dissolving
the components of the sample, which is a prerequisite for using LC.
5. The pH of the mobile phase is adjusted using a calibrated pH meter with glass and thermal compensation electrodes.
6. A prerequisite in LC–MS is that the analyte must be ionizable in solution, so the mobile
phase often contains a small amount of a volatile acid or base. If such additives impair the
chromatographic separation, they can be added after the separation, before the eluent
enters the ESI interface. The separation of the triazine herbicides and their metabolite is
tested at various compositions of the eluent and at different pH values. Because of their
polar character, the triazines do not interact strongly with the C18 reversed phase, the
most utilized stationary phase in LC. Thus, it is necessary to add acetic acid to the mobile
phase to increase the molecular ionization of the compounds, which also improves the
detection in analysis by MS.
7. Quantification can also be performed by LC with UV detection. The UV detector is set at
220 nm as a compromise between the maximum absorbance of the analytes and the reduced background of the eluents at this wavelength (11). Acetonitrile is chosen as an
organic modifier in the mobile phase owing to its low absorbance background in the UV
region.
8. After defining the conditions for SIM of the triazines, the product ions are recorded with
a single quadrupole set at a fixed m/z value representing [M + H]+. A urine sample is a
complex matrix consisting of various components; therefore, it is essential to use an
extraction procedure to remove these interferents. However, using SIM, no problem is
encountered in the quantification of the analytes because only the ion corresponding to
each compound is selectively monitored.
9. The method must be validated using the instrumentation with which the analyses will be
made. According to our results for validation of this method (12), analytical curves are
obtained using standard solutions of the triazines, and they showed good linearity in the
range from LOQ to 800 µg/L with correlation coefficients > 0.999. The following values
are easily obtained for the validation parameters: average recoveries ranging from 82 to
114%; of 0.4 µg/L LOD; 1.3 µg/L LOQ; and precision values of 0.5% (repeatability) and
2.4% (intermediate precision). These values are considered acceptable for biological
samples (11).
110
Jardim, Pozzebon, and Queiroz
Acknowledgments
We acknowledge FAPESP for financial support and a fellowship (to J. M. P.). We
also thank C. H. Collins and W. Vilegas for helpful discussions and suggestions.
References
1. Mendas, G., Drevenkar, V., and Zupancic-Kralj, L. (2001) Solid-phase extraction with
styrene-divinylbenzene sorbent for high-performance liquid or gas chromatographic determination of urinary chloro- and methylthiotriazines. J. Chromatogr. A 918, 351–359.
2. Catenacci, G., Barbieri, F., Bersani, M., Fereoli, A., Cottica, D., and Maroni, M. (1993)
Biological monitoring of human exposure to atrazine. Toxicol. Lett. 69, 217–222.
3. Mendas, G., Tkalcevic, B., and Drevenkar, V. (2000) Determination of chloro- and
methylthiotriazine compounds in human urine: extraction for gas chromatographic analysis with nitrogen-selective and electron capture detection. Anal. Chim. Acta 424, 7–18.
4. Perry, M. J., Christiani, D. C., Mathew, J., Degenhart, D., Tortorelli, J., Strauss, J., and
Sonzogni, W. C. (2000) Urinalysis of atrazine exposure in farm pesticide applicators.
Toxicol. Ind. Health 16, 285–290.
5. Catenacci, G., Maroni, M., Cottica, D., and Pozzoli, L. Assessment of human exposure to
atrazine through the determination of free atrazine in urine. Bull. Environ. Contam.
Toxicol. 44, 1–7.
6. Barr, D. A. and Needham, L. (2002) Analytical methods for biological monitoring of exposure to pesticides: a review. J. Chromatogr. B 778, 5–29.
7. Hogendoorn, E. and van Zoonen, P. (2000) Recent and future developments of liquid chromatography in pesticide trace analysis. J. Chromatogr. A 892, 435–453.
8. Careri, M., Mangia, A., and Musci, M. (1996) Applications of liquid chromatographymass spectrometry interfacing systems in food analysis: pesticide, drug and toxic substance residues. J. Chromatogr. A 727, 153–184.
9. Henion, J., Brewer, E., and Rule, G. (1998) Sample preparation for LC/MS/MS: analyzing
biological and environmental samples. Anal. Chem. 70, 650A–656A.
10. Causon, R. (1997) Validation of chromatographic methods in biomedical analysis. Viewpoint and discussion. J. Chromatogr. B 689, 175–180.
11. Sacchero, G., Apone, S., Sarzanini, C., and Mentasti, E. (1994) Chromatographic
behaviour of triazine compounds. J. Chromatogr. A 668, 365–370.
12. Pozzebon, J. M., Vilegas, W., and Jardim, I. C. S. F. (2003) Determination of herbicides
and a metabolite in human urine by liquid chromatography–electrospray ionization mass
spectrometry. J. Chromatogr. A 987, 375–380.
Chlorinated Phenols by GC or LC–MS
111
9
Analysis of Pentachlorophenol and Other Chlorinated
Phenols in Biological Samples by Gas Chromatography
or Liquid Chromatography–Mass Spectrometry
Ji Y. Zhang
Summary
Gas chromatographic (GC) and liquid chromatographic (LC)–mass spectrometric
(MS) methods have been described to analyze pentachlorophenol and other chlorinated
phenols in biological samples. After addition of internal standard (ISTD), the samples
are hydrolyzed with sulfuric acid to release free phenols. The mixtures are extracted
using liquid–liquid extraction or solid-phase extraction, including solid-phase
microextraction. The resulting samples are injected onto GC–MS or LC–MS for analysis. Selected ion monitoring with a mass spectrometer is used to detect chlorinated
phenols. The linearity is obtained in a wide range, from 0.1 to 100 ng/mL, with limit of
detection at low nanograms/milliliter for the GC–MS method. The LC–MS technique in
negative ion detection provides good linearity and reproducibility for chlorinated phenols
using atmospheric pressure chemical ionization (APCI) ion sources. However, detection
limits for the LC–MS method are higher than for the GC–MS method.
Key Words: Chlorinated phenols; gas chromatography–mass spectrometry; liquid
chromatography–mass spectrometry; liquid–liquid extraction; pentachlorophenol; solidphase extraction; solid-phase microextraction.
1. Introduction
Pentachlorophenol (PCP) and related chloronated phenols (CPs) are commonly
used chemicals that have extensively distributed throughout the environment (1). CPs
can be detected in human tissues following both occupational and ambient exposures
(2–4). These compounds are considered to be procarcinogen in rodents (5) and possibly in humans (6,7), for whom the liver is the target organ of toxicity and carcinogenicity. PCP and some of the CPs have been included in the US Environmental
Protection Agency list of 11 priority pollutant phenols in water (8). Gas chromatography (GC) and liquid chromatography (LC) coupled with mass spectrometry (MS) have
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
111
112
Zhang
been widely used to detect PCP and other CPs in environmental (9–12) and biological
samples (13–18). With liquid–liquid extraction or solid-phase extraction (SPE) for
purifying and concentrating samples, GC–MS and LC–MS methods can provide the
sensitivity and specificity needed for measurement of PCP or CPs in biological
samples. This chapter discusses several extraction procedures and GC–MS and LC–
MS methods for determination of PCP or CPs in biological samples. Suitable extraction and detection methods can be selected for combination use based on interest and
capability of the laboratory.
2. Materials
1. Pesticide-quality solvents ethanol, ethyl acetate, toluene, isopropanol, and acetone.
2. Acetic anhydride and pyridine.
3. Standards of the CPs, including PCP and the ISTD 2,3,4,6-tetrachlorophenol (2,3,4,6TeCP) with purity higher than 98% (e.g., Sigma-Aldrich, Milwaukee, WI).
4. Analytical-grade sulfuric acid, potassium carbonate, and sodium hydroxide.
5. High-purity water is obtained using a Millipore system (Milford, MA).
6. Human urine and plasma blank acquired from healthy human volunteers who did not take
any medications for at least 1 mo.
7. Ultrahigh-purity helium (minimum purity 99.999%).
8. Centrifuge.
9. C18 SPE cartridges (Bond Elut SPE 300 mg, 5-cc reservoir; e.g. Varian, Harbor City,
CA).
10. C18 SPE disk (47 mm id, 3M, MN).
11. Solid-phase microextractor (SPME) fiber coated with an 85-µm film thickness
polyacrylate (e.g., Supelco, Bellefonte, PA).
12. Gas chromatograph (e.g., Hewlett-Packard MS Engine GC–MS, Palo Alto, CA) equipped
with a split/splitless programmed temperature injector and an autosampler.
13. A 3-m fused-silica capillary column for GC with 0.25-mm id, 0.5-µm thickness (e.g.,
DB-5.635, J&W Scientific, Folsom, CA).
14. Liquid chromatograph with an autosampler and an MSD mass spectrometer (e.g., Agilent
1100 series HPLC, Agilent Technologies, Palo Alto, CA).
15. A 150 × 2.1 mm id, 3-µm particle size column for LC (e.g., Thermo Hypersil, Bellefonte, PA).
3. Methods (see Note 1)
3.1. Preparation of Standard and Quality Control Samples
1. For primary solutions (200 µg/mL), weigh 20 mg of each standard, as well as of the
ISTD, into a 100-mL volumetric flask and fill the flask with isopropanol (see Note 2).
2. For the secondary solutions (2 µg/mL), transfer 1 mL each of the primary solution for all
standards into a 100-mL volumetric flask and fill the flask with isopropanol:water (50:50
v/v) to obtain a work solution containing all the target compounds (see Note 2).
3. For the ISTD solution (500 ng/mL), transfer 250 µL of the ISTD primary solution into a
100-mL volumetric flask and fill the flask with acetone (see Note 2).
4. Spike urine or plasma with aliquots of secondary solution to obtain 0.1, 0.5, 1, 5, 10, 50,
75, and 100 ng/mL concentrations of the calibration standards.
5. Urine and plasma pools spiked with CPs at 0.1, 5, 10, and 100 ng/mL are prepared for
quality control (QC) (see Note 3).
6. The calibration standards and QC standards are aliquoted and stored in a freezer at
approx −20°C.
Chlorinated Phenols by GC or LC–MS
113
3.2. Liquid–Liquid Extraction
1. Thaw the frozen urine or plasma samples in a water bath at room temperature and centrifuge at 2000g for 5 min at 4°C.
2. Place a 5-mL aliquot of each urine sample into a screw-capped test tube.
3. Add 50 µL of a solution of ISTD (500 ng/mL) in acetone.
4. Hydrolyze the samples with 120 µL of concentrated sulfuric acid at 100°C for 60 min.
5. Cool to room temperature and extract the urine samples with 4 mL of toluene by agitating
the mixture for 2 min.
6. Centrifuge the samples for 5 min at 3000g to break up the emulsions.
7. Remove the upper organic layer, acetylate with 100 mL of acetic anhydride-pyridine (5:2
v/v), and then agitate for 2 min.
8. Remove the excess acetylation reagent by shaking with 2 mL of 100 mM potassium carbonate buffer for 2 min.
9. Centrifuge, then take the organic layer, and dry with sodium sulfate.
10. For plasma samples, dilute 1 mL of the plasma with the same volume of water before
addition of ISTD.
11. Extract the plasma samples in the same way as for urine but without hydrolysis (see Note 4).
12. Concentrate the extracts to approx 0.5 mL and directly inject onto GC–MS for analysis
(see Note 5).
13. The samples are underivatized for LC–MS analysis.
14. The extracts need to be dried under nitrogen and resolubilized in 20 µL of acetonitrile
before LC–MS analysis.
3.3. Solid-Phase Extraction
1. Place cartridges or disks on a vacuum manifold and condition with 2 mL of methanol and
2 mL of water.
2. Pass the urine, after hydrolysis, or the diluted plasma through the cartridge or disk.
3. Elute with 2 mL of ethyl acetate, concentrate by evaporation under a steam of nitrogen,
and then resolubilize in 20 µL of acetonitrile before GC–MS or LC–MS analysis.
3.4. Solid-Phase Microextraction
1. Add HCl to adjust the pH of the urine samples to pH 1.0 (see Note 6).
2. Condition the fibers under helium in the hot injector of the gas chromatograph at 300°C
for 2–3 h prior to use.
3. Perform SPME in a 40-mL vial containing 25 mL of urine and equipped with a 1-in. stir
bar and a stirring plate. During the extraction, the urine samples are continuously agitated
at around 700g.
4. Continue the extraction of PCPs and CPs in urine samples with SPME for 50 min (see
Note 7).
5. Set the needle on the SPME manual holder at its maximum length (4 cm) in the GC
injector.
6. Use a desorption temperature of 290°C for 2 min, which produces the highest sensitivity
for detection of PCPs and CPs.
3.5. Gas Chromatography–Mass Spectrometry
1. Perform GC–MS analyses using injector in the splitless mode.
2. Keep helium carrier gas at a rate of 1 mL/min. For fiber injection, the injector is held
isothermally at 290°C. The temperature of the transfer line is held at 310°C.
114
Zhang
3. Maintain the ion source of the mass spectrometer at 250°C and 150°C for electronic impact and chemical ionization (CI), respectively.
4. Set the column initially at 60°C, ramped at 30°C/min to 190°C and from 190 to 310°C at
a rate of 10°C/min.
5. Use electron impact ionization with a 70°C electron energy, positive chemical ionization
(PCI) and negative chemical ionization (NCI) with methane as reagent gas to trace the
optimum ionization mode for analysis of PCPs and CPs.
6. Use single-ion monitoring (SIM) to detect the phenols and ISTD at the nominal molecular mass and isotopic molecular mass at a constant ratio of CPs (Table 1). The ions used
for quantitation are the molecular ions of CPs (see Note 8).
3.6. Liquid Chromatography–Mass Spectrometry
1. Use a mobile phase of (A) aqueous ammonium acetate/acetic acid (5 mM, pH 4.5), (B)
acetonitrile, and (C) methanol at a flow rate of 0.2 mL/min. The elution program starts at
an initial composition of A:B:C (60:30:10 v/v/v), and the isocratic step is maintained up
to 29 min; then, the composition is programmed to A:B:C (12:86:2 v/v/v) in 5 min and
held at this composition for 6 min. Finally, the mobile phase is returned to the initial
composition in 2 min and reequilibrated for 10 min before the next injection.
2. Atmospheric pressure chemical ionization (APCI) in negative mode is used with a 400°C
vaporizer temperature; −4000-V needle voltage; 70-V fragmentor potential; nebulizer and
dry gas (nitrogen) at 60 psi and 12 L/min, respectively. The APCI interface and MS parameters are optimized to obtain maximum sensitivity at unit resolution.
3. Use SIM to enhance sensitivity by monitoring [M-H]- ions (see Note 8).
3.7. Quantitation and Performance Characteristics
1. Use SIM mode analysis to generate the peak areas of CPs and ISTD.
2. Calculate the ratios of the peak areas of CPs to ISTD.
3. Build calibration curves by a weighted (1/Concentration2) least-squares linear regression
analysis.
4. Estimate concentrations of CPs in the samples using the equations from the appropriate
calibration curves.
5. For GC–MS analysis, linearity of the standard curves is between 0.1 and 100 ng/mL. The
lowest limit of quantitation (LLOQ) is 0.1 ng/mL (see Note 9) for all CPs.
6. For LC–MS analysis, standard curves are linear from 5 to 100 ng/mL, with a 5 ng/mL
LLOQ.
7. Acceptable precision (≤15%) and accuracy (100 ± 15%) are obtained for concentrations
above the sensitivity limit and within the standard curve range for both GC–MS and LC–
MS analysis.
4. Notes
1. All glassware should be silanized prior to use by socking the glassware overnight in toluene solution at a concentration of 10% dichlorodimethylsilane. The glassware is rinsed
with toluene and methanol, then dried in an oven for 2 h. Commercially available silanized
glassware can be used without further silanization.
2. The stock solutions were kept refrigerated (4°C) and discarded 1 mo after preparation.
3. The calibration standards and QC samples are prepared with appropriate volumes of stock
solutions in 100-mL volumetric flasks by diluting to the volumes with human urine or
plasma to achieve the desired concentrations.
tR
Selected ion/confirmed ion (isotope ratio)
115
No.
Compound
(min)
EI
PCI
NCI
1
2
3
4
5
2-Chlorophenol (2-CP)
2,4-Dichlorophenol (2, 4-DCP)
2,4,6-Trichlorophenol (2,4,6-TCP)
2,3,4,6-Tetrachlorophenol (2,3,4,5-TeCP)
Pentachlorphenol (PCP)
3.35
4.34
5.34
6.64
8.17
128/130 (3:1)
162/164 (3:2)
196/198 (1:1)
232/230 (4:3)
266/264/268 (15:9:10)
129/131 (3:1)
163/165 (3:2)
197/199 (3:1)
233/231 (4:3)
267/269 (3:2)
128/130 (3:1)
162/164 (3:2)
196/198 (1:1)
232/230 (4:3)
230/232 (3:2)
Chlorinated Phenols by GC or LC–MS
Table 1
Analytical Conditions of CPs as Determined by GC–MS
Reprinted with permission from ref. 14. Copyright 1998 Elsevier.
115
116
Zhang
Fig. 1. Mass ion chromatogram produced by SPME–GC–MS of (A) 25 µg/L CPs in urine at
pH 7.0 and (B) at pH 1.0; (C) blank urine. Numbers on the peaks correspond to those in Table
1. Reprinted with permission from ref. 14. Copyright 1998 Elsevier.
4. CPs are excreted in urine as free forms and sulfate and glucuronide conjugates, with the
amount of conjugation depending on the particular CP and its concentrations in urine.
However, CPs exist as free forms in plasma.
5. Acylation has been used in derivatization of CPs for GC–MS analysis for several reasons.
First, acylation reduces the polarity of the phenol groups, which in the underivatized
forms may not chromatograph very well because of nonspecific absorption effects, such
as tailing and ghost peaks. Second, acylation improves volatility on CPs, making them
more accessible to GC analysis. Third, acylation may help to separate closely related
CPs, which in the underivatized state may be difficult to resolve.
6. Extraction efficiency of CPs can be enhanced by decreasing the solubility of CPs in biological fluids. It is found that the best recovery is achieved by adjusting pH to approx 1.0
(Fig. 1). Because the extraction enhancement is related to the K values of CPs, a higher
increased factor is obtained with higher K value compounds. The extraction recovery for
PCP at pH 1.0 is approx 9 greater than that obtained in the original solution (pH 8.0).
Addition of saturated salts such as sodium chloride and potassium chloride combined
with acidification did not improve the extraction efficiency of CPs.
Chlorinated Phenols by GC or LC–MS
117
7. The efficiency of the extraction depends on the time. Good recoveries can be obtained
with time extraction longer than 40 min.
8. The use of the SIM technique in GC–MS and LC–MS analysis offers a second dimension
for compound identification. In addition to retention time, the ratios of ion clusters caused
by chlorine isotopes are used for identifying the CPs. The following criteria are used in
the identification (otherwise, no compounds are considered detected): at the retention
times of analytes deviation between the isotopic ratios obtained from the analysis, and the
theoretical values should be less than 13%. Also, for quantitation, the peak will be calculated only when the signal-to-noise ratio is greater than 3.
9. LLOQ is the lowest concentration of QCs that meets validation criteria with a precision
of ⱕ15% and accuracy of ⱕ100 ± 15%.
References
1. Jensen, J. (1996) Chlorophenols in the terrestrial environment. Rev. Environ. Contam.
Toxicol. 146, 25–51.
2. Ahlborg, U. G., Lindgren, J. E., and Mercier, M. (1974) Metabolism of pentachlorophenol. Arch. Toxicol. 32, 271–281.
3. Ahlborg, U. G. and Thunberg, T. (1980) Chlorinated phenols: occurrence, toxicity,
metabolism and environmental impact. CRC Crit. Rev. Toxicol. 7, 1–35.
4. Kutz, F. W. and Cook, B. T. (1992) Selected pesticide residue and metabolites in urine
from a survey of the US general population. J. Toxicol. Environ. Health 37, 277–291.
5. Schwetz, B. A., Quast, J. F., Keeler, P. A., Humiston, C. G., and Kociba, R. J.(1978)
Results of 2-year toxicity and reproduction studies on pentachlorophenol in rats, in Pentachlorophenol: Chemistry, Pharmacology, and Environmental Toxicology (Rao, K. R.,
ed.), Plenum Press, New York, pp. 301–309.
6. Hardell, L. and Sandstorm, A. (1979) Case–control study: soft-tissue sarcomas and exposure to phenoxyacetic acid or chlorophenols. Br. J. Cancer 39, 711–717.
7. Pearce, N. E., Smith, A. H., Howard, J. K., Sheppard, R. A., Giles, H. J., and Teague, C. A.
(1986) Non-Hodgkin’s lymphoma and exposure to phenoxyherbicides, chlorophenols, fencing work, and meat work employment: a case–control study. Br. J. Ind. Med. 43, 75–83.
8. (1997) Sampling and Analysis Procedure for Screening of Industrial Effluents for Priority
Pollutants. U.S. Environment Monitoring and Support Laboratory, Cincinnati, OH.
9. Jauregui, O., Moyano, E., and Galceran, M. T. (1997) Liquid chromatography–atmospheric pressure ionization mass spectrometry for the determination of chloro- and
nitrophenolic compounds in tap water and sea water. J. Chromatogr. A 787, 79–89.
10. Ribeiro, A. Neves, M. H., Almeida, M. F., Alves, A., and Santos, L. (2002) Direct determination of chlorophenols in landfill leachates by solid-phase micro-extraction-gas chromatography-mass spectrometry. J. Chromatogr. A 975, 267–274.
11. Hanada, Y., Imaizumi, I., Kido, K., et al. (2002) Application of a pentaflurobenzyl bromide derivatization method in gas chromatography/mass spectrometry of trace levels of
halogenated phenols in air, water and sediment samples. Anal. Sci. 18, 655–659.
12. Sarrion, M. N., Santos, F. J., Moyano, E., and Galceran, M. T. (2003) Solid-phase
microextraction liquid chromatography/tandem mass spectrometry for the analysis of
chlorophenols in environmental samples. Rapid Commun. Mass Spectrom. 17, 39–48.
13. Hargesheimer, E. E. and Coutts, R. T. (1983) Selected ion mass spectrometric identification of chlorophenol residues in human urine. J. Assoc. Off. Anal. Chem. 66, 13–21.
14. Lee, M., Yeh, Y, Hsiang, W., and Chen, C. (1998) Application of solid-phase
microextraction and gas chromatography–mass spectrometry for the determination of
chlorophenols in urine. J. Chromatogr. B 707, 91–97.
118
Zhang
15. Crespin, M. A., Gallego, M., and Valcarcel, M. (2002) Solid-phase extraction method for
the determination of free and conjugated phenol compounds in human urine. J.
Chromatogr. B 773, 89–96.
16. Kontsas, H., Rosenberg C., Pfaffli, P., and Jappinen, P. (1995) Gas chromatographic–
mass spectrometric determination of chlorophenols in the urine of sawmill workers with
past use of chlorophenol-containing anti-stain agents. Analyst 120, 1745–1749.
17. Treble, R. G., and Thompson, T. S. (1996) Normal values for pentachlorophenol in urine
samples collected from a general population. J. Anal. Toxicol. 20, 313–317.
18. Hovander, L., Malmberg, T., Athanasiadou, M., et al. (2002) Identification of hydroxylated PCB metabolites and other phenolic halogenated pollutants in human blood plasma.
Arch. Environ. Contam. Toxicol. 42, 105–117.
2,4-D Pesticide Radioimmunoassay
119
10
Analysis of 2,4-Dichlorophenoxyacetic Acid in Body Fluids
of Exposed Subjects Using Radioimmunoassay
Dietmar Knopp
Summary
The development of a radioimmunological method (radioimmunoassay, RIA) for the
determination of the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) in human body
fluids such as blood serum and urine is described. It comprises three major parts. The
first part deals with the generation of a polyclonal anti-2,4-D antiserum in rabbits. This
includes the preparation, purification, and characterization of 2,4-D–protein conjugates
(immunogens), immunization of rabbits, and evaluation of antiserum quality. A guide is
presented that with high probability will lead to useful antibodies. The second part outlines the synthesis and purification of the tracer (i.e., a tritiated 2,4-D with high specific
activity) that is selectively labeled in the 6-position of the aromatic moiety. The third
part describes carrying out the RIA, setting up the calibration curve, cross-reactivity
testing, and evaluation of matrix interferences.
Key Words: Cross-reactivity; 2,4-dichlorophenoxyacetic acid; exposed subjects;
herbicide; immunization; immunoassay; immunogens; matrix interferences; polyclonal
antibodies; radioimmunoassay; serum; tracer synthesis; urine.
1. Introduction
Immunoassay technology has been used successfully for decades in the clinical
laboratory as an extraordinarily effective analytical approach for both low and high
molecular analytes of clinical importance (1). The use of immunoassay has further
expanded to application for the determination of chemical pollutants in environmental
monitoring and human exposure assessment (2).
The new technique opened its road to success with the use of radioisotopes as labels. Radioactivity can be measured very easily and precisely; therefore, radioimmunoassays (RIAs) are known to be robust and less affected by matrix interferences. As
a disadvantage, instrumentation is rather complex, and dealing with radioactive materials is subject to strict regulations governing use and disposal. As a consequence,
development and use of RIA is restricted to special laboratories only.
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
119
120
Knopp
The search for alternative labels led to the enzymeimmunoassay (EIA), that is, the
use of enzymes as labels in conjunction with a suitable substrate to produce an assay
signal. As radioisotopes, enzymes offer a wide range of formats as well. RIA appears
to have diminished in its significance as judged by corresponding publications. However, radioisotopes are widely used, particularly in research.
In this chapter, the development of an RIA for the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) is described (3). It involves the generation of a polyclonal anti-2,4D antiserum in rabbits, the synthesis and purification of a tritiated 2,4-D that is
selectively labeled in the 6-position of the aromatic moiety, and carrying out the RIA.
Corresponding research was initiated in the early 1980s when the World Health Organization asked for data on the individual body burden of occupationally exposed workers to enable better assessment of the potential health hazard of this chemical (4). The
RIA was successfully used to determine 2,4-D in different samples, such as blood and
urine samples of (1) employees in the chemical industry, (2) herbicide sprayers in
agriculture and forestry industries, and (3) accidentally exposed persons (5–7). The
assay was further applied to study herbicide resorption and excretion in rats and the
behavior of 2,4-D, if present in the dialysate solution, during hemodialysis treatment (8,9).
According to the described schedule, RIA development is possible also with other
chlorinated phenoxyalcanoic acids. As an example, the immunoassay for 2-(2,4dichlorophenoxy) propionic acid should be mentioned (10).
2. Materials
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
2,4-D.
Research-grade crystalline bovine serum albumin (BSA).
Tri-n-butylamine.
Isobutyl chloroformate.
2,4,6-Trinitrobenzenesulfonic acid (TNBS).
Ultraviolet/visible (UV/Vis) spectrophotometer.
Sodium azide.
Dialysis tubing.
Freund’s complete and incomplete adjuvants (e.g., Difco Laboratories).
10% Pd/CaCO3.
Liquid scintillation counter (LSC)/beta scintillation counter (LSC).
Liquid scintillator cocktail such as Ultima cocktails (e.g., Perkin Elmer, Boston, MA).
Silica gel thin-layer chromatographic (TLC) plates.
Thin-layer scanner.
RIA buffer (dilution buffer for antiserum, tracer, and samples): 50 mM sodium phosphate
buffer, pH 7.4, 150 mM NaCl, 0.1% sodium azide, 0.1% gelatin (stable at 4°C for up to 1 mo).
UV lamp.
Human γ-globulin (HGG).
Polyethylene glycol (PEG) solution: 36.7 mM PEG 6000 in RIA buffer (stable at 4°C for
up to 1 mo).
Dialysis buffer: 10 mM glycine buffer, pH 9.0 (stable at 4°C up to 1 mo).
Freeze-dryer.
Vortex mixer.
2,4-D Pesticide Radioimmunoassay
121
Fig. 1. Schematic presentation of the 2,4-D–BSA conjugate (inmunogen).
3. Methods
The methods described outline (1) the synthesis and characterization of a 2,4-D–
protein conjugate, (2) the generation of polyclonal 2,4-D antibodies in rabbits and
their characterization, (3) the synthesis and purification of [6-3H]2,4-D, and (4) the
performance of the RIA.
3.1. 2,4-D–Protein Conjugate
Small molecules (haptens) do not alone elicit an immune response. They have to be
conjugated covalently to a larger carrier molecule before immunization (reviewed in
ref. 11; see Fig. 1). The steps described in Subheadings 3.1.1.–3.1.3. outline the procedure for the preparation, purification, and characterization of the immunogen used
for the subsequent immunization.
3.1.1. Preparation of 2,4-D–Protein Conjugates
Conjugates are prepared by the mixed anhydride method (12).
1. Dissolve 0.1 mmol 2,4-D in 3 mL dry dioxane and add an equimolar amount of tri-nbutylamine.
2. Cool the solution to about 5°C (put the solution into a refrigerator).
3. Add an equimolar amount of isobutyl chloroformate, vortex the solution, and put it again
into the refrigerator for about 20 min (solution A).
122
Knopp
4. Dissolve 40 mg BSA in 6 mL distilled water and 2 mL dioxane (solution B) (see Note 1).
5. Add solution A drop by drop to solution B and keep the mixture at room temperature for
at least 4 h.
3.1.2. Purification of the 2,4-D–Protein Conjugate
Methods of purification involve dialysis and gel filtration chromatography.
Although more time consuming, dialysis is reliable and very simple to perform.
1. Fill the coupling mixture into a dialysis tubing and close both ends of the tubing carefully
(see Note 2).
2. Take a 1-L beaker and fill it with dialysis buffer. Put the filled tubing into the buffer and
dialyze for 2 d against glycine buffer (dialysis buffer) and 1 d against distilled water. Stirring with a magnetic stirrer and frequent changes of the dialysate will accelerate dialysis.
3. After finishing dialysis, open one end of the tubing and put the liquid into a glass vessel
for subsequent freeze-drying (see Note 3).
4. Put the lyophilized conjugate into a tube and store it in the refrigerator.
3.1.3. Characterization of the 2,4-D–Protein Conjugate
Determination of the extent of incorporation of a hapten into the conjugate is
strongly recommended. Optimum coupling density depends on the selected carrier
protein, although there is no consensus regarding which ratio is best. What is important is not the molar ratio, but the packing density; that is larger proteins should have
higher substitution ratios. If available, a small amount of radio-labeled hapten of
known specific activity could be included in the conjugation reaction. Another possibility available is matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) (13). As a limitation, it can only be applied for smaller
immunogens such as serum albumins. A more general indirect method for conjugates
that are produced by reaction of ε-lysine-amino groups is measurement of the remaining free amino groups in the conjugate. The method of Habeeb involves titration of
free amino groups with TNBS (14).
1. Dissolve protein conjugate at a concentration of 2.4 mg/mL in 1N NaOH.
2. To 0.3 mL of conjugate solution, add the subsequent same amount of 1N HCl, 1.4 mL 4%
sodium bicarbonate solution at pH 8.5, and 1 mL of 0.1% aqueous TNBS solution. Mix
and incubate for 2 h at 40°C.
3. Add 1 mL 10% sodium dodecyl sulfate solution and 0.5 mL of 1N HCl. Mix and measure
absorbance at 335 nm. As a reference, use an analogously treated solution that contains
no protein.
4. Calculate the number of free amino groups n according to the formula (see Note 4)
n = (∆E MWprot)/(εNH2 Cprot)
where ∆E is the difference of extinction between conjugate and reference sample, MWprot
is the molecular weight of protein, Cprot is the molar concentration of protein, and εNH2 is
the molar extinction coefficient of a single free amino group of the carrier protein.
3.2. Generation of Antibodies
Antibodies can be obtained from a number of sources (reviewed in ref. 15). The
generation of polyclonal 2,4-D antibodies is described in Subheadings 3.2.1.–3.2.4.
This includes the immunization of rabbits and the evaluation of antiserum quality.
2,4-D Pesticide Radioimmunoassay
123
3.2.1. Immunization of Rabbits
Immunize two or more adult rabbits (weight depends on breed) intradermally at 10
multiple sites by injecting 0.1-mL aliquots of the emulsified 2,4-D–BSA conjugate,
which is prepared by dissolving 2 mg conjugate in 1 mL sterilized physiological saline
solution and emulsifying with 1 mL Freund’s adjuvant to give a stable water-in-oil
emulsion (see Note 5). For the initial immunization (priming), Freund’s complete adjuvant is used. Administer further immunizations (booster injections) 8 wk after priming and then about five times at 4-wk intervals with Freund’s incomplete adjuvant (see
Note 6). Seven to 10 d after each boost, bleed approx 2 mL from a marginal ear vein of
each rabbit to assess the progress of the immunization by performing the 2,4-D RIA
(see Note 7).
3.2.2. Evaluation of Antiserum Quality
During the course of immunization, the quantity (titer; this is the dilution of antiserum that will bind typically 50% of the mass of tracer added to the assay tube) and
quality (specificity, affinity, and sensitivity to matrix interferences) of the generated
2,4-D antibodies should be checked. Therefore, from the blood taken after each boost
either serum or plasma is separated from blood cells and submitted to testing by the
RIA (see Note 8). For antiserum assessment, perform the RIA as described in Subheading 3.4.1. with some modifications.
1. Prepare an antibody dilution curve without analyte but with different antiserum dilutions
(e.g., 1/10 to 1/105). Use RIA buffer as the sample matrix.
2. Plot percentage of bond tracer against antiserum dilution to obtain a sigmoidal dilution curve.
3. Repeat steps 1 and 2 with the addition of analyte concentration equivalent to the required
limit of detection. Use RIA buffer as the sample matrix. The resulting curve is termed the
displacement curve (see Note 9).
4. Repeat steps 1 and 2 with a serially diluted blank serum (from a nonimmunized animal)
instead of antiserum to assess nonspecific binding across the antiserum dilution range.
Use RIA buffer as the sample matrix.
5. Repeat steps 1 and 2 with the addition of test compound at a concentration of about 100fold above that of the analyte of interest, for which lack of cross-reactivity in the assay is
critical. Use RIA buffer as the sample matrix.
6. Establish two calibration curves as described in Subheading 3.4.2. using standard dilutions prepared (1) with RIA buffer and (2) with sample medium/RIA buffer (10:90 v/v)
(see Note 10).
When titer and quality are satisfactory, greater amounts of blood are collected from
the ear vein (do not collect more than 50 mL of blood at one time). Separate serum and
divide it into 1-mL aliquots for storage at lower temperatures (see Note 7).
3.3. Tracer Synthesis
Tracer synthesis is described in Subheadings 3.3.1 and 3.3.2 and includes (1) the
synthesis of 6-bromo-2,4-D, (2) the radio-labeling with tritium, and (3) the purification of [6-3H]2,4-D (see Fig. 2).
3.3.1. Synthesis of 6-Bromo-2,4-Dichlorophenoxyacetic Acid
1. Dissolve 50 g 2,4-dichlorophenol in a mixture of 250 mL water and 250 mL acetic acid.
124
Knopp
Fig. 2. Scheme of tracer synthesis.
2. Dissolve 16.5 mL bromine in 90 mL acetic acid and add to dichlorophenol solution under
stirring with a glass agitator (see Note 11). After cooling, the solution grows stiff to
form a pulp.
3. Add an excess of water and filtrate the formed precipitate over a paper filter.
4. Wash the precipitate extensively with about 500 mL of boiling water.
5. Recrystallize the solid precipitate in a water/ethanol mixture.
6. Check the purity of the 6-bromo-2,4-dichlorophenol, for example, by determination of its
melting point (68–69°C) or by TLC using a silica gel TLC plate and cyclohexane/benzene/acetic acid/paraffin (100:15:10:5 v/v/v/v) as mobile phase over a distance of 10 cm
beyond the origin. For detection, spray the dried TLC plate with silver nitrate reagent
solution (2.12 g silver nitrate, 12.5 mL distilled water, 3.75 mL 5N ammonia solution; fill
to 250 mL with acetone) and expose to UV light (e.g., CAMAG UV lamp) until the halogen-containing compounds become visible as darkish spots (see Note 12).
7. Dissolve 5 g 6-bromo-2,4-dichlorophenol in 30 mL 70% aqueous monochloroacetic acid
and adjust the final pH between 10.0 and 12.0 by adding 30% sodium hydroxide solution.
8. Boil the reaction mixture under reflux and stirring for 4 h.
9. Cool the solution to room temperature, collect the precipitate on a ceramic frit, and redissolve it in diethyl ether.
10. Shake the ether solution intensively with about the same volume of a 0.5% aqueous sodium hydrogencarbonate solution in a separation funnel.
11. Discard the organic phase and acidify the aqueous phase with concentrated sulfuric acid.
12. Add about the same volume of diethyl ether to dissolve the precipitate in the organic phase.
13. Separate the ether phase in a separation funnel
14. Repeat steps 10–13.
15. Remove the organic solvent by vacuum evaporation.
16. Check the purity of the 6-bromo-2,4-dichlorophenoxyacetic acid, for example, by determination of its melting point (181–184°C) or by TLC as described in step 6 (see Note 13).
3.3.2. Preparation of [6-3H]2,4-Dichlorophenoxyacetic Acid
Low-level radioactive materials are often used as tracers and labels. Dealings with
radioactive materials are subject to strict regulations governing use and disposal. Only
2,4-D Pesticide Radioimmunoassay
125
trained laboratory personnel should handle radioactive materials. The following catalytic hydrogenation with 3H gas is reserved for special laboratories only. Generally,
the radiochemical should be put at a customer’s disposal from corresponding suppliers
(e.g., GE Healthcare, formerly Amersham Biosciences, Uppsala, Sweden).
1. Dissolve 0.05 mmol 6-bromo-2,4-dichlorophenoxyacetic acid in 2 mL dry dioxane in a
round-bottom glass piston.
2. Add 300 mg catalyst (10% Pd/CaCO3).
3. Freeze the solution with liquid nitrogen and append the piston to the vacuum-handling
apparatus.
4. Exhaust the apparatus and thaw the solution by warming.
5. Induce tritium gas to start the hydrogenation. Stir the solution gently with a magnetic
stirrer for the entire reaction time at room temperature.
6. Absorption of tritium is finished after about 75 min.
7. Stop the reaction after another 60 min, freeze the solution with liquid nitrogen, and take
down the piston from the installation.
8. Thaw the solution and separate the catalyst by centrifugation at 1500g for 10 min.
9. Remove the solvent from the clear supernatant by freeze-drying.
10. Redissolve the residue in ethanol and store the solution for 48 h at room temperature (see
Note 14).
11. Remove the solvent by lyophilization and redissolve the residue in 10 mL ethanol.
12. Measure total radioactivity of the solution (e.g., on an LSC).
13. Purify the [6-3H]2,4-D by preparative TLC: 10-µL fractions of the ethanolic solution are
applied at a distance of 3 cm on TLC plates (silica gel G 60/kieselgur G, 2:3). On a
separate trace, apply nonradioactive 2,4-D as a control. Plates are developed with cyclohexane/benzene/acetic acid/paraffin (100:15:10:5 v/v/v/v) as the mobile phase over a distance of 18 cm beyond the origin. Plates are air dried. Detect nonradioactive 2,4-D by
spraying the separate trace with silver nitrate solution, followed by exposure to UV light.
If a radio-TLC scanner is available, it can be used to scan the radioactive traces completely. Scrape off the silica gel layer of the radioactive traces from the TLC plate in the
area (distance from origin) of the nonradioactive 2,4-D spot (see Note 15).
14. Extract the silica gel with ice-cold methanol and repeat TLC (step 13) to confirm radiochemical purity of the compound. Store the solution at −20°C. Radiochemical purity
higher than 95% can be obtained easily (see Note 16).
3.4. Radioimmunoassay
3.4.1. Procedure
The immunoassay is performed in 3-mL throwaway polyethylene tubes (RIA
tubes), which fit into commercial 20-mL LSC vials. As diluent, use RIA buffer. Equilibrate all reagents to room temperature before use (see Fig. 3).
1.
2.
3.
4.
5.
6.
7.
Add 100 µL 1:40 diluted normal rabbit serum (see Note 17).
Add 100 µL sample (see Note 18).
Add 100 µL diluted tracer [6-3H]2,4-D (see Note 19).
Add 100 µL antiserum dilution and close the tube (see Note 20).
Vortex for 10 s and incubate for 24 h at 4°C (see Note 21).
Open the tube and add 100 µL 0.33% HGG solution (see Note 22).
Add 1 mL PEG solution and close the tube.
126
Knopp
Fig. 3. Flow chart of the 2,4-D radioimmunoassay. NRS, normal rabbitt serum, from
nonimmunized animal.
8.
9.
10.
11.
12.
13.
14.
Vortex for 10 s and incubate an additional 30 min at 4°C.
Centrifuge at 3000g for 10 min (see Note 23).
Open the tube and aspirate the supernatant carefully with a Pasteur pipet (see Note 24).
Redissolve the pellet with 200 µL distilled water.
Add 1 mL scintillator cocktail and close the tube (see Note 25).
Vortex the tube vigorously and put it into a 20-mL glass scintillation vial (see Note 26).
Screw down the scintillation vial and measure the radioactivity for at least 10 min on an
LSC. The measured radioactivity (e.g., given as cpm) represents the antibody bond tracer B.
15. Interpolate analyte amount of unknown sample from the calibration curve.
3.4.2. Calibration Curve
Required assay sensitivity for human biomonitoring studies is in the nanogram- or
picogram-per-milliliter range. Performance must strictly be controlled for each matrix
type, which is under investigation.
1. Prepare stock solution by dissolving 25 mg 2,4-D in 100 mL methanol.
2. Prepare standard solutions (10, 50, 100, 500, 1000, 2500, 5000, 10,000 ng/mL) by appropriate dilution of the methanolic stock (from 1:25 to 1:25,000; v/v) with sample medium.
3. Prepare 1:10 (v/v) dilutions of standards with dilution buffer.
4. To measure total counts T, add 100 µL diluted tracer into an empty RIA tube and mix
with 1 mL scintillator cocktail.
5. Prepare all samples in triplicate and measure radioactivity.
2,4-D Pesticide Radioimmunoassay
127
6. Calculate data, for example, with weighted linear regression analysis of logit B/B0 vs log
dose or with spline function using appropriate software (e.g., GraphPad Prism 4 or
RiaCalc evaluation program) (see Note 27). Use normal rabbit serum dilution of a
nonimmunized animal as a blank and subtract corresponding counts as background (nonspecific binding) from each data point (see Note 20).
7. Determine intra- and interassay precision by repetitive analysis of replicates of different
standard samples over the working range of the calibration curve (see Note 28).
3.4.3. Cross-Reactivity Testing
For the user of an immunoassay, it is very important to know which analytes can be
trapped in the assay. The ability of the antiserum to discriminate between structurally
related chemicals, called specificity, can be tested by incubating a fixed amount of
antiserum and tracer with varying amounts of test chemicals. The corresponding procedure is known as cross-reactivity testing (16). First, other chlorinated phenoxyacid
herbicides and related phenols (possible metabolites) should be included (see Fig. 4
and Note 29). Use the same procedure as described in Subheading 3.4.1. but prepare
higher competitor concentrations of 200 to 8000 ng/mL of sample medium. Calculate
percentage cross-reactivity according to the following formula:
%CR = [(2,4-D Concentration at 50% antibody binding)/(Concentration of the test chemical
at 50% antibody binding)] × 100
3.4.4. Matrix Interferences
Antibodies are the key reagents in immunoassays. These proteins are sensitive to
nonphysiological conditions to a different extent. Concluding from this, all physical
and chemical factors that can interfere with the protein structure can also adversely
affect the assay. Considering biological samples such as blood serum/plasma and urine,
these are sample pH and ionic strength mainly. The effect of these parameters can be
checked very easily by simple modification of the RIA buffer regarding pH, molarity,
and even buffer type.
4. Notes
1.
2.
3.
4.
5.
6.
In general, 2,4-D should be coupled to a soluble carrier. Besides BSA, other proteins such
as keyhole limpet hemocyanin and thyroglobulin are known to be excellent carrier proteins.
Most easily, plastic clips should be used. One end of the tube should be closed with a
magnetic clip to allow comfortable moving of the tubing on a magnetic stirrer during
dialysis.
Depending on the freeze-dryer, either glass pistons or glass dishes can be used.
Generally, we use a second carrier protein sample that is treated in the same way but
without addition of the analyte (2,4-D) as a reference for the maximal absorbance (i.e.,
for the total number of measurable free amino groups).
For successful immunization, it is most important to prepare a stable emulsion. It can be
tested by expelling a small droplet of the mixture onto the surface of some water in a
beaker. The droplet should form a stable bead.
Repeated immunization with Freund’s complete adjuvant will lead to severe lesions at
the site of injection, which should be avoided. Besides Freund’s adjuvant, a number of
other immunological adjuvants such as Ribi Adjuvant, TiterMax, AdjuPrime, Adjuvax,
128
Knopp
Fig. 4. Phenoxyalcanoic acid herbicides that should be included in cross-reactivity testing
(2,4-D: 2,4-dichlorophenoxyacetic acid; 2,4-DME: (2,4-dichlorophenoxy)acetic acid methyl
ester; 2,4,5-T: (2,4,5-trichlorophenoxy)acetic acid; MCPA: 2-methyl-4-chlorophenoxyacetic acid;
2,4-DP: 2,4-dichlorophenoxypropionic acid; MCPP: 2-(2-methyl-4-chlorophenoxy)propionic acid;
2,4-DPME: 2,4-dichlorophenoxypropionic acid methyl ester; 2,4-DB: 4-(2,4-dichlorophenoxy)butyric
acid; MCPB: 4-(2-methyl-4-chlorophenoxy)butyric acid.
2,4-D Pesticide Radioimmunoassay
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
129
and others are known to enhance or modify the immune response to coadministered antigens. Generally, the examiner’s experience and preference seem to be most important for
the choice of adjuvant. The number of necessary booster injections varies and depends on
several factors, such as type of immunogen, the animal, route of immunization, dose of
antigen, choice of adjuvant, and so on.
Bleeding of rabbits requires a little more skill than immunizing them. The easiest method
is to cut the vein with a clean razor blade. Collect the blood by allowing it to drip into a
clean test tube. For preparation of serum, blood should be allowed to clot at 4°C overnight. Serum should be removed carefully with a Pasteur pipet. After preparation, serum
can be stored for many years at −20°C or in liquid nitrogen.
Although many different techniques are available for evaluating antibodies, the method
used should reflect the ultimate use of the antibody. In the present case, therefore, the 2,4D RIA should be used. This means that the tracer and other necessary reagents must be
prepared or made available very early during assay development. However, the sensitivity of the assay, which is ultimately related to the affinity of the antibodies, is dependent
on the assay conditions. Work at this stage will only give an indication of what is ultimately attainable.
The greater the shift of the displacement curve compared to the antibody dilution curve,
the higher is the affinity of the generated antibodies (i.e., the higher is the sensitivity of
the assay).
In the case of the absence of matrix effects, both calibration curves are almost identical.
Generally, matrix effect disappears using higher sample dilutions. However, this may
interfere with the required sensitivity.
Bromine vapor is highly toxic and may lead to irritation of eyes and mucous membranes
of the respiratory organs. Direct contact with the chemical should be avoided, and the
experiment should be performed under a fume hood.
Besides the synthesized compound, the starting compound (2,4-dichlorophenol) should
be applied to the plate as a reference. The retardation factor Rf, which is defined as the
ratio of the migration distance of the analyte to the migration distance of the mobile
phase, is clearly higher for the 6-bromo-2,4-dichlorophenol (compared to the
nonbrominated counterpart). A yield of about 25% will be obtained.
A yield of about 75% will be obtained. For TLC, as reference, 2,4-D should be applied.
Similar to the phenols (see Note 12), Rf value is higher for the brominated acid compared
to the nonbrominated compound. If a radio-TLC scanner is available, it can be used to
scan the radioactive traces completely. From the resulting chromatogram, the radiochemical purity of the labeled 2,4-D can easily be evaluated and its position on the TLC plate
accurately be localized. In default of a scanner, the position of the non-radio-labeled 2,4D is used as a reference for its radio-labeled counterpart.
During this time, tritium (which is unstable bound to the phenoxyacetic acid) is removed.
Purification is possible readily also by preparative high-performance liquid chromatography, if available.
Radiolyses (i.e., the disintegration of radio-labeled chemical compounds by radiation of
nuclides during storage of the compounds) is a well-known phenomenon. It is recommended to store the radiochemical in the absence of light and at low temperature. Further,
the radiochemical concentration should be low (i.e., as high a dilution as possible) should
be used. The latter will be specified by the intended use. Check radiochemical purity at
12-wk intervals. If necessary, repeat purification.
Normal rabbit serum can be obtained from a nonimmunized rabbit. Working dilution
should be prepared fresh.
130
Knopp
18. No or only minimal sample preparation is one of the outstanding properties of immunological methods. This depends mainly on the claimed sensitivity and selectivity, the robustness of the assay, and sample matrix type. According to the 2,4-D concentration, the
sample should be analyzed by the RIA at an appropriate dilution. Generally, serum and
urine sample dilutions lower than 1:10 interfere with the immunological method.
19. Prepare a tracer dilution to achieve about 12,000 cpm in a volume of 100 µL. For a [63H]2,4-D tracer with a specific radioactivity of 465 GBq/mmol, as prepared in our study,
this corresponds to about 380 pg tracer per assay tube. Working dilution should be prepared fresh.
20. Ideally, a preimmune serum as a reference should be collected from each animal selected
for the production of 2,4-D antibodies to estimate the progress of antibody generation in
the course of the immunization (i.e., for the evaluation of different bleedings). Antiserum
working dilution should be prepared fresh. Use an antiserum dilution that binds about
50% of the tracer added to the test tube.
21. During assay optimization, other conditions such as room temperature and shorter incubation times should be tested. Higher temperature may lead to faster attainment of equilibration, hence quicker assays.
22. A small amount of HGG has to be added as a bulking agent to obtain a visible white
precipitate in the antibody precipitation (step 9) to prevent its exhaustion during aspiration (step 10).
23. Use a fixed-angle rotor.
24. Aspirate supernatant from the bottom of the tube opposite the precipitate.
25. Use of a commercial scintillator is recommended, which gives high counting efficiency
for tritium and forms a stable microemulsion with up to 20% (v/v) of aqueous sample. If
possible, use newer safety cocktails that are less hazardous (e.g., Ultima-Flo M for serum
samples and Ultima Gold LLT for urine samples, both from Perkin Elmer). In any case,
follow hazard warnings and safety phrases clearly visible on the packing.
26. Use of plastic throwaway tubes is more economic and comfortable because much less
liquid scintillator cocktail is necessary (only approx 7% compared to the use of 20-mL
glass vials), and careful repetitive cleaning of vials can be avoided.
27. B and B0 represent counts bound by the antiserum in the presence or absence of nonradio-labeled 2,4-D (sample analyte).
28. Delete calibration standards within the quantitation range if they are not within ±20% of
the nominal value and the coefficient of variation of the triplicates is not ⱕ15%. The
curve fit can be considered acceptable if five or more points remain.
29. Be aware of interference by structurally related pharmaceuticals. As an example, in our
experiments false-positive results (2,4-D present in the sample) have been caused by
meclofenoxate [p-chlorophenoxyacetic acid-2-(dimethylamino)ethyl ester]. As a metabolite, 4-chlorophenoxyacetic acid is formed in the body that reacted with the 2,4-D antibodies.
References
1. Diamandis, E. P. and Christopoulos, T. K. (eds.). (1997) Immunoassay. Academic Press,
New York.
2. Aga, D. S. and Thurman, E. M. (eds.). (1996) Immunochemical Technology for Environmental Applications. ACS Symposium Series 657, ACS, Washington, DC.
3. Knopp, D., Nuhn, P., and Dobberkau, H.-J. (1985) Radioimmunoassay for 2,4-dichlorophenoxyacetic acid. Arch. Toxicol. 58, 27–32.
4. World Health Organization. (1984) 2,4-Dichlorophenoxyacetic acid (2,4-D). Environmental Health Criteria 29, WHO, Geneva.
2,4-D Pesticide Radioimmunoassay
131
5. Knopp, D. (1994) Assessment of exposure to 2,4-dichlorophenoxyacetic acid in the chemical
industry: results of a five year biological monitoring. Occup. Environ. Med. 51, 152–159.
6. Knopp, D. and Glass, S. (1991) Biological monitoring of 2,4-dichlorophenoxyacetic acidexposed workers in agriculture and forestry. Int. Arch. Occup. Environ. Health 63, 329–333.
7. Knopp, D., Schmid, M., and Niessner, R. (1993) Accidental bystander overexposure to the
herbicide 2,4-dichlorophenoxyacetic acid. Fresen. Environ. Bull. 2, 148–150.
8. Knopp, D. and Schiller, F. (1992) Oral and dermal application of 2,4-dichlorophenoxyacetic acid sodium and dimethylamine salts to male rats: investigations on absorption and
excretion as well as induction of hepatic mixed-function oxidase activities. Arch. Toxicol.
66, 170–174.
9. Knopp, D., Unger, G., and Niessner, R. (1994) Organic trace contaminants in water—a
potential health hazard for chronic dialysis patients. Zbl. Hyg. 195, 509–515.
10. Knopp, D., Skerswetat, M., Schmid, M., and Niessner, R. (1993) Preparation and characterization of polyclonal antibodies against the herbicide 2-(2,4-dichlorophenoxy)propionic
acid (dichlorprop). Fresenius Environ. Bull. 2, 274–280.
11. Hermanson, G. T. (ed.). (1996) Bioconjugate Techniques. Academic Press, New York.
12. Erlanger, B. F. (1973) Principles and methods for the preparation of drug protein conjugates for immunological studies. Pharmacol. Rev. 25 , 271–280.
13. Wengatz, I., Schmid, R., Kreissig, S., et al. (1992) Determination of the hapten density of
immunoconjugates by matrix-assisted UV laser desorption ionization mass-spectrometry.
Anal. Lett. 25, 1983–1997.
14. Habeeb, A. F. S. A. (1966) Determination of free amino groups in proteins by
trinitrobenzenesulfonic acid. Anal. Biochem. 14, 328–336.
15. Harlow, E. and Lane D. (eds.) (1988) Antibodies: A Laboratory Manual. Cold Spring
Harbor Laboratory (www.cshlpress.com).
16. Abraham, G. E. (1969) Solid-phase radioimmunoassay of estradiol-17β. J. Clin.
Endocrinol. Metab. 29, 866–870.
HTS–IS–ELISA for Biomonitoring Chlorophenols
133
11
A High-Throughput Screening Immunochemical Protocol
for Biological Exposure Assessment of Chlorophenols
in Urine Samples
Mikaela Nichkova and M.-Pilar Marco
Summary
This chapter presents a high-throughput screening (HTS) immunochemical procedure suitable for processing and analyzing simultaneously multiple urine samples. The
method presented here is addressed to assess the level of exposure of the population to
certain organochlorine substances (i.e., dioxins, lindane, hexachlorobenzene,
chlorophenols, etc.) by analyzing the concentration of chlorophenols in urine. The procedure consists mainly of three steps. First, the urine samples are treated in basic media
to hydrolyze the glucuronide and sulfate conjugates of the chlorophenols. Next, the free
chlorophenol fractions are selectively isolated by immunosorbents (ISs), specially prepared for this purpose. Finally, this fraction is quantified with a microplate ELISA (enzyme-linked immunosorbent assay). All solid-phase extraction (SPE) and analytical
methods can be performed on a 96-plate configuration. The HTS–IS–ELISA procedure
has been proved to be efficient, consistent, and reliable. The main advantages are the
simplicity, the high sample throughput capabilities, and the small urine sample volumes
required for each assay. With the present analytical protocol, quantitation can be accurately performed within 0.3 and 30 µg/L 2,4,6-trichlorophenol. About 100 samples per
day can be processed with inter- and intraassay precision (%CV) below 20%, except
when measurements take place at the level of the ELISA limit of detection. A protocol
such as that presented here may be generally applied in environmental or biological
monitoring programs for which many complex samples have to be screened as far as
antibodies with the necessary specificity and affinity are available.
Key Words: Biomarker; chlorophenols; dioxins; ELISA; exposure; hexachlorobenzene;
HTS; immunoaffinity extraction; lindane; 96-well immunosorbent SPE; urine.
1. Introduction
The monitoring of chlorophenols in human urine is normally used as an indication
of exposure to chlorophenols or to compounds having chlorinated phenols as products
of metabolism, such as chlorobenzenes, hexachlorobenzene, hexachlorocyclohexanes,
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
133
134
Nichkova and Marco
and chlorophenoxycarboxylic acids (1–3), which are widely used as solvents, deodorants, disinfectants, and plant-protecting agents. A continuous excretion of
trichlorophenols may also indicate a risk of dioxin exposure (4,5). Determination of
the actual chlorophenol intake by the population would provide a reliable estimation
of the individual health risk because of environmental (6–10) and occupational exposure (11–16).
Immunochemical techniques are gaining application in the area of human exposure
assessment (17,18), offering rapid, simple, and cost-effective alternative approaches
for analytical screening. High sample throughput is a feature of immunoassays that
makes them particularly suited to large-scale biomonitoring studies. Numerous urinary immunoassays (enzyme-linked immunosorbent assay, ELISA) have been developed as screening tools to a variety of industrial chemicals, trace contaminants, and
pesticides (for review, see refs. 19–21). Mostly, immunoassay interferences are
avoided by simple dilution of the biological sample, which means simply reducing,
but not removing, the interfering component. However, the interferences caused by
matrix components may vary from sample to sample, especially in complex biological
matrices from a large number of individuals. Thus, removing the interfering compounds would result in more controlled analysis for human biomonitoring purposes.
Immunoaffinity extraction, using immunosorbents (ISs) as solid-phase extraction
(SPE) stationary phases, of low molecular weight analytes from complex environmental and biological matrices provides highly selective extraction based on specific molecular recognition and minimizes reliance on organic solvents to achieve efficient
separation (22–24). Furthermore, antibody cross-reactivity allows multiresidue analysis targeting of a parent compound and its metabolites or a class of structurally related
analytes.
Here, we present an application of extraction performed in 96-column format
coupled to ELISA (high-throughput screening–immunosorbent–ELISA, HTS-ISELISA) for the urinary detection of chlorophenols as an analytical tool for biological
exposure assessment. The detailed evaluation and optimization of the HTS–IS–ELISA
method for chlorophenol urinary determination was reported in our previous work
(25). The optimized HTS-IS-ELISA protocol presented here consists of three main
steps: urine hydrolysis, chlorophenol extraction by HTS-IS-SPE, and ELISA quantification. The method was validated by gas chromatography coupled to mass spectrometry (GC–MS) analysis of more than 100 urine samples from different individuals, and
an excellent correlation between both methods was observed (25).
The methodology described here could be applied to the immunochemical determination of other urinary metabolites if specific antibodies against them are available. In
this case, it is necessary to optimize the HTS–IS–SPE conditions (sample volume,
washing and elution, loading level effects, etc.) to achieve quantitative extraction and
to eliminate possible matrix effects on the ELISA. Furthermore, the HTS–IS–SPE of
chlorophenols can be used as a cleanup method prior to their chromatographic identification and determination by GC-MS and gas chromatography with electron capture
detection (GC/ECD).
HTS–IS–ELISA for Biomonitoring Chlorophenols
135
2. Materials
2.1. Standards and Quality Controls
1. 2,4,6-Trichlorophenol (2,4,6-TCP).
2. Ethanol (EtOH).
3. Phosphate-buffered saline (PBS) buffer: 10 mM phosphate buffer, 0.8% saline solution,
pH 7.5.
4. Dimethylsulfoxide (DMSO).
2.2. Urine Samples
1. Urine samples (see Note 1 regarding their collection). Keep urine samples aliquoted (12
mL) at –30°C. Volume needed for two replicate analyses is 12 mL.
2. Pooled urine sample from different individuals (who tested negative for specific drugs of
abuse; e.g., Bio-Rad Laboratories) is used as a control matrix.
3. 15M KOH.
4. Concentrated H2SO4.
5. Sand bath.
2.3. High-Throughput Screening–Immunosorbent–Solid-Phase Extraction
1. Immunosorbent based on immunoglobulin G (IgG) fraction of polyclonal antisera As45
against 2,4,6-TCP (26,27) coupled to NHS (N-hydroxysuccinimide) activated Sepharose®
4 Fast Flow (e.g., Pharmacia Biotech). About 25 mL of gel suspension is needed to fill 96
columns (see Note 2).
2. VersaPlate 96-Well SPE System consisting of a 96-well baseplate, 96 removable empty
columns, and a vacuum manifold set (e.g., Varian, Sunnyvale, CA).
3. Vacuum controller (mechanical gages).
4. VersaPlate accessories (disposable waste reservoir, cartridge removal tool, 20-mm pore
frits, 96 glass vials (0.75 mL) in a collection rack, 96-well microplate Teflon-coated silicone rubber seal, sealing tape pads, and sealing caps) (e.g., Varian).
5. Multichannel electronic pipet (50–1200 mL) (e.g., Eppendorf, Hamburg, Germany).
2.4. Enzyme-Linked Immunosorbent Assay
1. Polyclonal antisera As43 against 2,4,6-TCP (26,27). A working aliquot is stored at 4°C
and remains stable for about 6 mo.
2. Coating antigen (8-BSA) is 3-(2-hydroxy-3,6-dichlorophenyl) propanoic acid coupled to
bovine serum albumin (BSA) by the active ester method (27). A stock solution of 1 mg
mL–1 is prepared in 10 mM PBS and kept at 4°C. The solution is stable for 1 mo.
3. 2,4,6-TCP. See Subheading 3.1. regarding preparation of the stock solution.
4. Goat antirabbit IgG (Sigma, A-8275). Store at –20°C in working aliquots. For continuous
use, store at 0–5°C.
5. PBS buffer: 10 mM phosphate buffer, 0.8 % saline solution, pH 7.5.
6. 7% EtOH/PBS: 10 mM PBS with 7% EtOH.
7. PBST buffer: PBS with 0.05% Tween 20.
8. Coating buffer: 50 mM carbonate–bicarbonate buffer, pH 9.6; store at 4°C.
9. Citrate buffer: 40 mM solution of sodium citrate at pH 5.5; store at 4°C.
10. 0.6% TMB (3,3',5,5'-tetramethylbenzidine) is prepared by dissolving 6 mg of TMB base
in 1 mL DMSO (dimethylsulfoxide). This stock solution should be stored at room temperature and protected from light.
136
Nichkova and Marco
11. For 1% H2O2, dilute 100 µL of 30% H2O2 in 3 mL water. This solution is stored in the
refrigerator on a plastic recipient for about 1 mo.
12. ELISA substrate solution: 0.01% TMB and 0.004% H2O2 in citrate buffer. Immediately
before use, for 25 mL of citrate buffer mix 400 µL TMB (0.6% DMSO) and 100 µL 1%
H2O2 .
13. Polystyrene microtiter 96-well plates (e.g., Nunc).
14. Microplate washer.
15. Microplate spectrometer.
16. Software: ELISA competitive curves are analyzed using SoftmaxPro (Molecular Devices).
3. Methods
The methods described outline (1) the preparation of quality controls (QCs), (2) the
urine hydrolysis (deconjugation step), (3) the HTS–IS–SPE extraction of chlorophenols,
and (4) their ELISA quantification.
3.1. Preparation of Standards and QCs
1. The stock solution of 2,4,6-TCP needed for the preparation of the ELISA standard curve
is 1 mM solution prepared in DMSO, and it should be stored at 4°C.
2. For QCs, a stock solution of 2,4,6-TCP at a concentration of 1 g/L is prepared in ethanol.
Standards of 2,4,6-TCP (80, 16, 8, and 1 mg/L concentrations) in PBS buffer (buffer
QCs) are prepared by further dilution with PBS. Urine QCs of the same concentrations
are prepared in a hydrolyzed pooled urine sample (see Subheading 3.2. for hydrolysis).
The urine QCs (6 mL each) are prepared by spiking with the corresponding volume of
500 mg/L 2,4,6-TCP standard solution prepared in PBS. All stock and QC solutions are
stored at 4°C.
3.2. Urine Hydrolysis (Deconjugation of Chlorophenol–Glucuronides
and Sulfates)
In biological monitoring studies it is important to determine the total urinary
chlorophenol concentration (free and conjugated) (see Note 3). Therefore, the
first step in the urine analysis is the hydrolysis of the chlorophenol conjugates.
Here, we suggest alkaline hydrolysis (see Note 4).
1. Add 2 mL 15M KOH to 10 mL urine sample in a glass vial, seal it, and heat it on a sand
bath for 30 min at 100°C.
2. Cool the sample to room temperature and neutralize it to pH 7.5 by adding dropwise
concentrated H2SO4 and mixing very well (see Note 5).
3. Centrifuge (10 min at 1520g) if a precipitation of salts or proteins is formed and use the
supernatant.
3.3. High-Throughput Screening–Immunosorbent–Solid-Phase Extraction
The detailed optimization, evaluation, and validation of the high-throughput–
immunoaffinity–solid-phase extraction (HTS–IS–SPE) (see Note 6) of chlorophenols
from urine samples were described in our previous work (25). We have also demonstrated that the extracts obtained after the HTS–IS–SPE have no matrix effects on the
ELISA measurements (28,29). Here, we present the optimized HTS–IS–SPE procedure that might be followed for efficient chlorophenol extraction from urine samples.
HTS–IS–ELISA for Biomonitoring Chlorophenols
137
3.3.1. HTS–IS–SPE Procedure
The HTS–IS–SPE procedure is performed with the VersaPlate 96-Well SPE System, which consists of a vacuum manifold set equipped with a vacuum controller and
water pump. All steps of the HTS–IS cleanup cycle are performed under gentle low
vacuum, maintaining a flow rate in the range 1–2 mL/min. The vacuum is manually
controlled to allow the different solvents (buffers, samples) to pass through the IS
extraction columns: The columns should be kept wet after both conditioning and loading steps and dried after the washing and elution steps. To protect the immunosorbent
from drying in the conditioning and loading steps, the vacuum should be stopped as
soon as the first columns are drained. All liquid loadings are done manually using an
eight-channel electronic pipet. During sample loading, washing, and regeneration
steps, waste is collected in the disposable reservoir. Before elution, the waste reservoir
should be replaced with the collection rack of 96 glass vials (0.75 mL).
The HTS–IS–SPE cycle consists of conditioning, sample loading, washing of the
unbound material, eluting of the specifically retained analyte, and regenerating of the
column for a next cycle (see Note 7).
1.
2.
3.
4.
5.
6.
7.
8.
Bring the columns to room temperature and wash them with 5 mL PBS.
Condition the columns by washing with 1.2 mL 70% EtOH followed by 1.2 mL PBS.
Load each column with 6 mL sample (spiked PBS, urine samples, and QCs).
Wash the columns with 1.2 mL PBS (if you want to elute the chlorophenol family) or
with 20% EtOH for more specific extraction (see Note 8).
Elute the bound chlorophenols with 0.6 mL 70% EtOH. For ELISA analysis, 0.1 mL of the
eluted fractions is diluted 10 times with 10 mM PBS to a 7% EtOH content (see Note 9).
Regenerate the columns with 1.2 mL PBS.
Dilute the collected extract 10 times with PBS and keep at 4°C sealed with a 96-well
microplate silicone rubber seal. Analyze the extracts by ELISA curve run in 7% EtOH/
PBS or by chromatographic analysis.
When not in use, store the VersaPlate 96-Well IS–SPE assembly sealed with caps at 4°C
in PBS containing 0.1% NaN3.
3.3.2. Quality Assurance
3.3.2.1. CONTROL OF COLUMN PREPARATION
As the ISs are packed manually, it is important to evaluate the variation in the
capacity of different columns. An experiment can be designed in which different columns placed in different positions of the rack holder are loaded with different amounts
of 2,4,6-TCP. Table 1 presents the recoveries obtained for HTS–IS–SPE of 2,4,6-TCP
from PBS standards of different concentrations (buffer QCs).
It should be noted that at the maximum capacity the columns are very reproducible
(%CV = 4.69, N = 10). The highest CV of 27.19% (N = 16) is observed for the lowest
loading level (0.72%). In general, in spite of the manual packing, the reproducibility
within columns is very good. If any of the prepared columns does not satisfy the above
characteristics, it should be discarded and replaced by a new column.
3.3.2.2. CONTROL OF IMMUNOSORBENT BINDING CAPACITY (SEE NOTE 10)
We strongly recommend the use of buffer and/or urine QCs in each HTS–IS–SPE
run to control the performance of the extraction procedure. A matrix blank (nonspiked
138
Nichkova and Marco
Table 1
Recovery Obtained for HTS–IS–SPE of 2,4,6-TCP From PBS Standards
(PBS Washing, 70% EtOH Elution in 0.6 mL)
Loading levela (%)
100
20
2.4
0.72
2,4,6-TCP (ng)
Nb
Recovery ± SD (%)
500
100
12
3.6
10
3
16
16
101.05 ± 4.74
84.81 ± 13.25
97.75 ± 16.84
95.77 ± 26.04
aSee
bN
Note 2.
is the number of mini-ISs used.
Table 2
Features of the 2,4,6-TCP Immunoassay (As43/8-BSA)
Parameter
Valuesa
Amax
Amin
IC50 (µg/L)
Dynamic range
Slope
LOD (µg/L)
r2
0.796 ± 0.174
0.018 ± 0.021
1.132 ± 0.361
0.288 ± 0.045 to 3.117 ± 0.679
1.22 ± 0.23
0.175 ± 0.027
0.991 ± 0.006
LOD, limit of detection.
aThe parameters are extracted from the four-parameter equation used to fit the standard curve. The data presented correspond
to the average of 34 calibration curves run in different plates in a
3-mo period. Each curve is built using two-well replicates.
pooled urine) can be used as a control for possible contamination. In addition, buffer
QCs (500, 100, 50, and 10 ng 2,4,6-TCP) corresponding to 100, 20, 10, and 2% loading levels, respectively, should be used regularly as QC of the immunosorbent-binding capacity within several applications of urine samples. Quantitative recovery (in
the range 80–100%) should be maintained for up to 35 analyses for all loading levels
according to our experience. If the binding capacity of some column decreases, the
column should be replaced by a new one. We observed that the recovery of 6% of the
96 IS (at 2.4% loading level) became lower than 40% after 30 cycles. This drawback
of the HTS–IS format can be improved with better packing of the columns or using
more resistant sorbent.
3.4. Enzyme-Linked Immunosorbent Assay
The ELISA (As43/8-BSA) for detection of 2,4,6-TCP was developed by Galve et
al. (27) (for immunoassay description, see Note 11). The assay parameters of the
immunoassay are summarized in Table 2.
HTS–IS–ELISA for Biomonitoring Chlorophenols
139
1. Coat the microtiter plates with 8-BSA in coating buffer (0.625 µg/mL, 100 µL/well) overnight at 4°C covered with adhesive plate sealers.
2. The following day, wash the plates four times with PBST.
3. Prepare a standard curve of 2,4,6-TCP standards (1000 to 0.625 nM in 7% EtOH/PBS) in
a separate mixing plate. The stock solution of 2,4,6-TCP is 1 mM in DMSO. The stock
solution is diluted 1/1000 in PBS to make a concentration of 1000 nM corresponding to
the highest concentration of the standard curve. Pipet 300 mL of this solution to well A1.
Pipet 270 mL of 7% EtOH/PBS into well B1 and 240 mL of 7% EtOH/PBS into well H1.
Pipet 150 mL of 7% EtOH/PBS into wells C1 through G1 of the mixing plate. Transfer 30
mL from well A1 to B1. Mix by gently drawing up and expelling the solution back into
the well three or four times. Transfer 150 mL from well B1 to C1 and mix. Continue to
transfer and mix. The last transfer of 150 mL is from well F1 to G1. Transfer 60 mL from
well G1 to H1 and mix. Pipet 150 mL of 7% EtOH/PBS into wells A2, A3, and A4 (zero
analyte concentration). This makes enough solution to run the calibration curve in duplicate on the coated ELISA plate.
4. Prepare serial dilutions in 7% EtOH/PBS of the HTS–IS–SPE extracts of the unknown
urine samples. For example, pipet 300 mL of one sample into well A4. Pipet 150 mL of
7% EtOH/PBS into wells B4 and C4. Transfer 150 mL from well A4 to B4 and mix.
Transfer 150 mL from well B4 to C4 and mix. This results in a sample that will be tested
neat, diluted by two and four. Larger dilutions may be made by adjusting volumes of
sample, diluent, and transfer volume appropriately. Each dilution can be analyzed in duplicate on the coated ELISA plate.
5. Add the 2,4,6-TCP standards and the samples to the coated plates (50 µL/well), followed by
the sera As43 (1/2000 in PBST, 50 µL/well), and incubate for 30 min at room temperature.
6. Wash the plates again four times with PBST.
7. Add a solution of goat antirabbit IgG coupled to horseradish peroxidase in PBST (1/
6000) to the wells (100 mL/well) and incubate for 30 min at room temperature.
8. Wash the plates four times with PBST.
9. Add the substrate solution (100 mL/well).
10. Stop color development after 30 min at room temperature with 4N H2SO4 (50 mL/well)
and read the absorbance at 450 nm.
11. Calculation of sample concentration using the standard curve. The concentration should
be reported in 2,4,6-TCP immunoreactivity equivalents (For ELISA crossreactivity see
Note 11). The standard curve should be fitted to a four-parameter logistic equation according to the following formula:
y = (A - B/[1 - (x/C)D]) + B
where A is the maximum absorbance, B is the minimum absorbance, C is the concentration producing 50% of the maximum absorbance, and D is the slope at the inflection point
of the sigmoidal curve (see Table 2).
12. Quality assurance and quality control of the HTS–IS–ELISA protocol. In each analysis, it
is necessary to run matrix spikes and blank sample through the entire procedure. We
suggest the analysis of unknown urine samples be performed in duplicate. The main features of the urinary analysis of 2,4,6-TCP by the HTS–IS–ELISA method are summarized in Table 3.
140
Nichkova and Marco
Table 3
Features of the Urinary Analysis of 2,4,6-TCP by HTS–IS–ELISA
Parameters
HTS–IS–ELISA
Sample volume
Speed of IS cleanup
Speed of total analysis
LODa (mg/L)
LOQb (mg/L)
MDCc (mg/L)
Interday precision (%CV)d
Intraday precision (%CV)e
Number of false positives
Number of false negatives
6 mL
96 samples/h
96 samples/d
0.3
0.55
30
17.4–22.9% for 0.7–8 mg/L (N = 24)
6.2–11.3% for 0.7–8 mg/L (N = 72)
0
0
aThe
limit of detection (LOD) is evaluated according to the LOD of the ELISA
(LOD7%EtOH/PBS = 0.2 mg/L, 90% of the signal at zero analyte concentration) and the
corresponding recoveries of the IS-SPE and of the hydrolysis.
bThe limit of quantification (LOQ) is evaluated according to the LOQ of the ELISA
(LOQ7%EtOH/PBS = 0.37 mg/L, 80% of the signal at zero analyte concentration) and the
corresponding recoveries of the IS-SPE and of the hydrolysis.
cMDC (maximum detectable concentration with recovery > 70%)
dThe %CV is the average of the %CVs for each concentration for each day (within
one 96-well SPE procedure).
eThe %CV corresponds to the recovery obtained for each concentration for 3 d
(between three 96-well SPEs). N is the number of ISs used for each concentration.
4. Notes
1. A study carried out with sawmill factory workers demonstrated that tri- and
tetrachlorophenols are excreted totally conjugated (97–92.9% for 24-h urine, 80.5–79.1%
for morning urine, and 86.4–81.6% for afternoon urine) and the extent of conjugation of
PCP (pentachlorophenol) is lower (76.2% for 24-h urine, 69% for afternoon urine) (29).
The urinary half-times for tri-, tetra-, and pentachlorophenol are 18 h, 4.3 d, and 16 d,
respectively.
2. The IgG fraction of As45 is isolated by 35% ammonium sulfate precipitation to remove
serum albumins according to a standard protocol (30). The obtained IgG is immobilized
to the NHS-activated Sepharose 4 Fast Flow gel by covalent coupling via the amino
groups as recommended by the manufacturer (Pharmacia Biotech). The NHS-activated
Sepharose 4 Fast Flow is highly cross-linked 4% agarose matrix with a 16–23 mmol
NHS/mL drained medium ligand density, 90-mm mean particle size, and 3.0–13.0 pH
stability. The antibody coupling can be performed at different scales (using 1, 5, 12, and
24 mL Sepharose suspension) with a coupling efficiency of about 97% in all cases (25).
The drained gel bed volume of each IS is 0.2 mL. This corresponds to maximum theoretical binding capacity for each column of approx 1 mg (5.1 nmol) 2,4,6-TCP; based on the
amount of IgG coupled (9.7 mg) and the assumption that bivalent binding takes place,
10% of the polyclonal IgG is specific, and 100% of the immobilized IgG is accessible. If
50% steric hindrance or no efficient antibody orientation is assumed, the theoretical binding capacity would be 0.5 mg (2.22 nmol) 2,4,6-TCP.
HTS–IS–ELISA for Biomonitoring Chlorophenols
141
3. Chlorophenols are excreted to the urine as such or in the form of glucuronide and sulfate
conjugates, with the amount of conjugation depending on the particular chlorophenol and
its concentration in the urine (29,31). At low concentration, sulfate conjugation is dominant, but when chlorophenol concentration increases, acid conjugation becomes more
important.
4. Alternatively, chlorophenol glucuronides and sulfates can be cleaved by acid (13) or enzymatic hydrolysis (29). However, we have demonstrated that for alkaline hydrolysis, quantitative analysis (extraction recovery higher than 70%) can be performed in a broader range
(1–20 mg/L 2,4,6-TCP urinary concentration) than for acid/enzymatic hydrolysis (28).
5. The neutral pH of the urine sample is very important to ensure effective antigen–antibody
interaction in the IS, resulting in an efficient immunoaffinity extraction.
6. SPE devices in a 96-well plate format were introduced in 1996, and they enjoyed widespread application and rapid acceptance in biotechnology and pharmaceutical laboratories, in which HTS is sought (32). The 96-well SPE sorbents (33) afford rapid
development and automation of SPE methods to eliminate traditional time-consuming
and labor-intensive sample preparation steps for environmental (34) and biological
samples (35–39). All these applications of 96-SPE formats are based on nonselective SPE
sorbents. However, the trends in SPE research are oriented not only toward reduction of
the SPE format and the automation for a high throughput, but also toward the development of more selective extraction procedures, such as those using immunoextraction sorbents (40). Immunoaffinity extraction provides highly selective extraction of low
molecular weight analytes from complex matrices based on the specific molecular recognition (22–24,41,42). Antibodies are covalently bonded onto an appropriate sorbent to
form the so-called immunosorbent. Single analytes can be targeted, but thanks to the
antibody cross-reactivity, immunoextraction sorbents have also been designed to target a
group of structurally related analytes. Because of antibody specificity, the problem of the
coextraction of matrix interferences is circumvented.
7. Detailed information about the basic principles and the factors affecting the IS–SPE procedures can be found in refs. 22, 23, and 43.
8. Halogenated phenols structurally related to 2,4,6-TCP are usually present in urine
samples. In previous work (28), we evaluated the selectivity of the IS–SPE procedure
described here and used IS with 1-mL bed size. The specificity studies were carried out
by GC/ECD analysis of the eluted fractions after toluene extraction and derivatization of
the chlorophenols with N,O–bis(trimethylsilyl) trifluoroacetamide. When a mixture of
penta-, tetra-, tri-, and dichlorophenol isomers and dibromophenols are loaded to the column (16 compounds, total loading level of the mixture is 20% [248 ng 2,4,6-TCP]), individual loading level is 1.7% (21 ng 2,4,6-TCP), and PBS washing is applied in the
cleanup; all penta-, tetrachlorophenols (2,3,4,6-TtCP, 2,3,4,5-TtCP, and 2,3,5,6-TtCP),
trichlorophenols (2,4,6-TCP, 2,4,5-TCP, 2,3,4-TCP, 2,3,5-TCP, and 2,3,6-TCP), 2,4,6tribromophenol, and 2,4-dibromophenol are retained in more than 80%. The
dichlorophenols are not detected in the eluted fractions. When the same mixture of halogenated phenols is loaded but 20% EtOH washing is used, the immunoaffinity extraction
is more specific: Only 2,4,6-TCP, 2,4,6-TBP, 2,3,4,6-TtCP, PCP, and 2,4-DBP were retained by the IS. Thus, when PBS washing is applied, the IS–SPE procedure can be used
as a class-selective IS–SPE of chlorophenols from urine samples that can be later analyzed by chromatographic or immunochemical methods. A more selective extraction can
be performed by washing with 20% ethanol buffer. If ELISA is used as a detection method
after both types of IS–SPE procedure, only the halogenated phenols with significant immunoassay cross-reactivity would be detected.
142
Nichkova and Marco
9. Chlorophenols can be identified and determined by GC/ECD or GC–MS. The 7% EtOH solutions obtained after the HTS–IS–SPE are extracted with toluene. Then, the chlorophenols are
derivatized with silylating agent [N,O-bis(trimethylsilyl)trifluoroacetamide] and directly analyzed (25,28).
10. An important issue to be considered when the HTS–IS–SPE protocol is used is the control of the immunosorbent stability (i.e., be sure that it keeps its efficient binding capacity). When water–organic modifier mixture is used for elution, the presence of nonpolar
solvents reduces the hydrophobic binding component of the antibody–antigen interaction. However, it also affects the stability of the hydrophobic bonds that maintain the
antibody tertiary structure, resulting in the release of the antigen. These harsh eluting
conditions can irreversibly denature antibodies, but because small volumes are required,
contact times can be minimized. In our studies, the regeneration of the IS is performed by
passing 10 bed volumes of PBS through the column. However, in the HTS–IS–SPE procedure, the washing and elution steps are performed until the columns are dried (to avoid
error in the collected volume), which can have a negative effect on the immunosorbent
stability. In addition, the backpressure formed is not equal for all the columns because
different resistance is created by the manually placed frits (different packing). The applied pressure to all the columns in the 96-well rack is not homogeneous. Some columns
get drier under elution. All these can create problems with column stability.
11. The antisera is raised against 3-(3-hydroxy-2,4,6-trichlorophenyl)propanoic acid covalently coupled by the mixed anhydride method to keyhole limpet hemocyanin. The
indirect ELISA uses a heterologous coating antigen prepared by conjugation of 3-(2hydroxy-3,6-dichlorophenyl)propanoic acid to BSA using the active ester method. The
assay performs well between pH 7.5 and 9.5, and it is inhibited at pH lower than 6.0. The
immunoassay detectabilities do not change significantly when the ionic strength of the
media is in the range 12–25 mS/cm. The ELISA for 2,4,6-TCP is quite specific, but some
cross-reactivity with other chlorinated phenols, such as 2,3,4,6-TtCP (21%), 2,4,5-TCP
(12%), and 2,3,5-TCP (15%), is observed. Brominated phenols are even more recognized
than the corresponding chlorinated analogues (e.g., 2,4,6-TBP, 710%; 2,4-DBP, 119%).
Acknowledgments
This work was supported by MCyT (AGL 2002-04653-C04-03) and EC (QLRT2000-01670). Mikaela Nichkova thanks the Spanish Ministry of Education for her
fellowship to the FPU program.
References
1. Angerer, J., Maaß, R., and Heinrich, R. (1983) Occupational exposure to hexachlorocyclohexane. VI. Metabolism of HCH in man. Int. Arch. Occup. Environ. Health 52, 59–67.
2. Hill, R. H., Jr., Head, S. L., Baker, S., et al. (1995) Pesticide residues in urine of adults
living in the United States: reference range concentrations. Environ. Res. 71, 99–108.
3. Guidotti, M., Ravaioli, G., and Vitali, M. (1999) Total p-nitrophenol determination in
urine samples of subjects exposed to parathion and methyl-parathion by SPME and GC/
MS. J. High Resolut. Chromatogr. 22, 628–630.
4. Wrbitzky, R., Angerer, J., and Lehnert, G. (1994) Chlorophenols in urine as an environmental medicine monitoring parameter. Gesundheitswesen 56, 629–635.
5. Wittsiepe, J., Kullmann, Y., Schrey, P., Selenka, F., and Wilhelm, M. (2000)
Myeloperoxidase-catalyzed formation of PCDD/F from chlorophenols. Chemosphere 40,
963–968.
HTS–IS–ELISA for Biomonitoring Chlorophenols
143
6. Angerer, J., Heinzow, B., Schaller, K. H., Weltle, D., and Lehnert, G. (1992) Determination of environmental caused chlorophenol levels in urine of the general population.
Fresenius J. Anal. Chem. 342, 433–438.
7. Hill, R. H., Jr., Ashley, D. L., Head, S. L., Needham, L. L., and Pirkle, J. L. (1995) pDichlorobenzene exposure among 1000 adults in the United States. Arch. Environ. Health
50, 277–280.
8. Schmid, K., Lederer, P., Goen, T., et al. (1997) Internal exposure to hazardous substances
of persons from various continents. Investigations on exposure to different organochlorine
compounds. Int. Arch. Occup. Environ. Health 69, 399–406.
9. Bartels, P., Ebeling, E., Kramer, B., et al. (1999) Determination of chlorophenols in urine
of children and suggestion of reference values. Fresenius J. Anal. Chem. 365, 458–464.
10. Lampi, P., Vohlonen, I., Tuomisto, J., and Heinonen, O. P. (2000) Increase of specific
symptoms after long-term use of chlorophenol polluted drinking water in a community.
Eur. J. Epidemiol. 16, 245–251.
11. Kauppinen, T., Kogevinas, M., Johnson, E., et al. (1993) Chemical exposure in manufacture of phenoxy herbicides and chlorophenols and in spraying of phenoxy herbicides. Am.
J. Ind. Med. 23, 903–920.
12. Wrbitzky, R., Goen, T., Letzel, S., Frank, F., and Angerer, J. (1995) Internal exposure of
waste incineration workers to organic and inorganic substances. Int. Arch. Occup. Environ.
Health 68, 13–21.
13. Kontsas, H., Rosenberg, C., Pfäffli, P., and Jäppinen, P. (1995) Gas chromatographicmass spectrometric determination of chlorophenols in the urine of sawmill workers with
past use of chlorophenol-containing anti-stain agents. Analyst 120, 1745–1749.
14. Kontsas, H., Rosenberg, C., Tornaeus, J., Mutanen, P., and Jappinen, P. (1998) Exposure
of workers to 2,3,7,8-substituted polychlorinated dibenzo-p-dioxin (PCDD) and
dibenzofuran (PCDF) compounds in sawmills previously using chlorophenol-containing
antistain agents. Arch. Environ. Health 53, 99–108.
15. Rosenberg, C., Kontsas, H., Tornaeus, J., et al. (1995) Chlorinated dioxin and dibenzofuran
levels in plasma of sawmill workers exposed to chlorophenol-containing anti-stain agents.
Organohalogen Comp. 26, 81–84.
16. Wrbitzky, R., Beyer, B., Thoma, H., et al. (2001) Internal exposure to polychlorinated
dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/PCDFs) of Bavarian chimney sweeps. Arch. Environ. Contam. Toxicol. 40, 136–140.
17. Van Emon, J. M. (2001) Immunochemical applications in environmental science. J. AOAC
Int. 84, 125–133.
18. Draper, W. M. (2001) Biological monitoring: exquisite research probes, risk assessment,
and routine exposure measurement. Anal. Chem. 73, 2745–2760.
19. Knopp, D. (1995) Application of immunological methods for the determination of environmental pollutants in human biomonitoring. A review. Anal. Chim. Acta 311, 383–392.
20. Biagini, R. E., Hull, R., Striley, C. A., et al. (1996) Biomonitoring for occupational exposure using immunoassay. In Environmental Immunochemical Methods. Perspectives and
Applications (Van Emon, J. M., Gerlach, C. L., and Johnson, J. C., eds.) ACS, Washington, DC, pp. 286–296.
21. Oubiña, A., Ballesteros, B., Carrasco, P. B., et al. (2000) Immunoassays for environmental analysis. In Sample Handling and Trace Analysis of Pollutants. Techniques, Applications and Quality Assurance (Barceló, D., ed.), Elsevier, Amsterdam, The Netherlands,
Vol. 21, pp. 289–340.
144
Nichkova and Marco
22. Delaunay, N., Pichon, V., and Hennion, M. C. (2000) Immunoaffinity solid-phase extraction for the trace-analysis of low-molecular-mass analytes in complex sample matrices. J.
Chromatogr. B 745, 15–37.
23. Stevenson, D. (2000) Immuno-affinity solid-phase extraction. J. Chromatogr. B 745, 39–48.
24. Weller, M. G. (2000) Immunochromatographic techniques—a critical review. Fresenius
J. Anal. Chem. 366, 635–645.
25. Nichkova, M. and Marco, M.-P. Development of HTS-IS-ELISA for urinary detection of
chlorophenols. Environ. Health Perspect., submitted.
26. Galve, R., Camps, F., Sanchez-Baeza, F., and Marco, M.-P. (2000) Development of an
immunochemical technique for the analysis of trichlorophenols using theoretical models.
Anal. Chem. 72, 2237–2246.
27. Galve, R., Nichkova, M., Camps, F., Sanchez-Baeza, F., and Marco, M.-P. (2002) Development and evaluation of an immunoassay for biological monitoring of chlorophenols in
urine as potential indicators of occupational exposure. Anal. Chem. 74, 468–478.
28. Nichkova, M. and Marco, M.-P. (2005) Development and evaluation of C18 and
immunosorbent solid-phase extraction methods prior immunochemical analysis of
chlorophenols in human urine Anal. Chim. Acta 533, 67–82.
29. Pekari, K., Luotamo, M., Järvisalo, J., Lindroos, L., and Aitio, A. (1991) Urinary excretion
of chlorinated phenols in saw-mill workers. Int. Arch. Occup. Environ. Health 63, 57–62.
30. Baines, M.G. and Thorpe R. (1992) Purification of Immunoglobulin G (IgG) In Immunochemical Protocols, Methods in Molecular Biology (Manson, M. M., ed.), Humana
Press, Totowa, NJ., Vol.10, pp.79–104
31. Drummond, I., van Roosmalen, P. B., and Kornicki, M. (1982) Determination of total PCP
in the urine of workers. A method incorporating hydrolysis, an internal standard and measurement by LC. Int. Arch. Occup. Environ. Health 50, 321–327.
32. Rossi, D. T. and Zhang, N. (2000) Automating solid-phase extraction: current aspects and
future prospects. J. Chromatogr. A 885, 97–113.
33. Wells, D. A. (1999) 96-well plate products for solid-phase extraction. LC GC North
America 17, 600-610.
34. Quayle, W. C., Jepson, I., and Fowlis, I. A. (1997) Simultaneous quantitation of 16 organochlorine pesticides in drinking waters using automated solid-phase extraction, highvolume injection, high-resolution gas chromatography. J. Chromatogr. A 773, 271–276.
35. Janiszewski, J., Schneider, R. A., Hoffmaster, K., Swyden, M., Wells, D., and Fouda, H.
(1997) Automated sample preparation using membrane microtiter extraction for
bioanalytical mass spectrometry. Rapid Commun. Mass Spectrom. 11, 1033–1037.
36. Souppart, C., Decherf, M., Humbert, H., and Maurer, G. (2001) Development of a high
throughput 96-well plate sample preparation method for the determination of trileptal
(oxcarbazepine) and its metabolites in human plasma. J. Chromatogr. B: Biomed. Sci.
Appl. 762, 9–15.
37. Shou, W. Z., Jiang, X., Beato, B. D., and Naidong, W. (2001) A highly automated 96-well
solid phase extraction and liquid chromatography/tandem mass spectrometry method for the
determination of fentanyl in human plasma. Rapid Commun. Mass Spectrom. 15, 466–476.
38. Rule, G. and Henion, J. (1999) High-throughput sample preparation and analysis using
96-well membrane solid-phase extraction and liquid chromatography–tandem mass spectrometry for the determination of steroids in human urine. J. Am. Soc. Mass Spectrom. 10,
1322–1327.
HTS–IS–ELISA for Biomonitoring Chlorophenols
145
39. Zhang, H. and Henion, J. (1999) Quantitative and qualitative determination of estrogen
sulfates in human urine by liquid chromatography/tandem mass spectrometry using 96well technology. Anal. Chem. 71, 3955–3964.
40. Hennion, M.-C. (1999) Solid-phase extraction: method development, sorbents, and coupling with liquid chromatography. J. Chromatogr. A 856, 3–54.
41. Pichon, V., Bouzige, M., Miege, C., and Hennion, M. C. (1999) Immunosorbents: natural
molecular recognition materials for sample preparation of complex environmental matrices. TrAC Trends Anal. Chem. 18, 219–235.
42. Rhemrev-Boom, M. M., Yates, M., Rudolph, M., and Raedts, M. (2001) (Immuno)affinity
chromatography: a versatile tool for fast and selective purification, concentration, isolation and analysis. J. Pharm. Biomed. Anal. 24, 825–833.
43. Ballesteros, B. and Marco, M.-P. (1998) Basic principles of the use of immunoaffinity
chromatography for environmental analysis. Food Technol. Biotechnol. 36, 145–155.
Postapplication Exposure Assessment
149
12
Assessment of Postapplication Exposure to Pesticides
in Agriculture
Joop J. van Hemmen, Katinka E. van der Jagt, and Derk H. Brouwer
Summary
Occupational exposure to pesticides may occur not only during the actual application
to crops and enclosed spaces, but also after the actual application when the crops are
handled (e.g., harvesting) or when treated spaces are reentered. This postapplication (reentry) exposure may occur on a daily basis (e.g., for harvesting of ornamentals or vegetables in greenhouses) and may have the duration of a full work shift. An overview is
given for the methodology that can be used for assessing the levels of exposure via skin
and inhalation. Such data are used for the risk assessment of the use scenarios relevant
for registration purposes throughout the world and form the basis for predictive exposure
modeling. For Europe, such a predictive postapplication exposure model is developed in
the EUROPOEM project funded by the European Union. Because exposure may have to
be reduced with various techniques in cases of anticipated unacceptable health risks, the
use of control measures comes into play, which are described for postapplication exposure. The assessment of internal exposure levels using biological monitoring methodology is also described.
Key Words: Biological monitoring; exposure modeling; fluorescent techniques;
gloves; hand washes; occupational exposure; personal protective equipment (PPE);
postapplication; reentry; tape stripping; whole body measurement; wiping.
1. Introduction
Agricultural crops, grown either indoors or outdoors, are frequently treated with
pesticides to prevent or rid pests of all kinds, such as weeds, insects, and fungi. In
doing so, either the ambient atmosphere (indoors) or the foliage or soil is treated with
amounts of pesticide that vary for effectivity, nature of the pest, degree of infestation,
and in practice the requirements posed by (inter)national regulations for export, such
as “no tolerance.” This means that the foliage and fruits of the crop become contaminated with pesticide residues that may or may not be removed or lost before workers
come into contact with the crop during various crop-related activities, such as harvestFrom: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
149
150
van Hemmen, van der Jagt, and Brouwer
ing. In practice, the applied amount and the time between application of the crop and
postapplication activities in the crop determines the level of exposure during these
activities. These levels are regulated by pesticide laws throughout the world. In Europe, the Plant Protection Products Directive (91/414/EC) requires a human health
risk assessment of exposure during application and postapplication (reentry) and of
exposure to bystanders present during application and postapplication activities.
In this chapter, the methodology for assessing exposure during postapplication is
described, as is the assessment of exposure for registration purposes. In Europe, the
EUROPOEM project has attempted to gather publicly available data for the risk assessment process required by European legislation for exposure during reentry of
treated crops and treated premises, such as greenhouses (1). Methodology is described
to assess internal exposure to pesticides, as well as methods to reduce exposure. An
overview of many exposure measurements carried out mainly in greenhouses is presented in ref. 2.
2. Materials and Methodology
The methodology for sampling the amount of exposure during postapplication
should in principle cover inhalation, skin exposure, and oral exposure. It might cover
either external exposure or internal exposure as assessed by biological monitoring.
Note, however, that oral exposure cannot yet be quantitatively estimated and is therefore either neglected or estimated together with exposures via the other routes of uptake
by biological monitoring.
These different methodologies are discussed to the extent needed for the present
purpose. The basic approach for exposure assessment to agricultural pesticides is presented in ref. 3. This is relevant for operators and reentry workers. A similar guidance
document is currently in preparation by the Organization for Economic Cooperation
and Development specifically for postapplication agricultural scenarios.
2.1. Inhalation Exposure Assessment
Aspiration efficiency and retention of the captured aerosols are key issues in the
performance of sampling devices. Aspiration efficiency is a device-depending property that varies with the aerodynamic diameter of the aerosol. Conventions have been
established to define aerosol size fraction and aspiration efficiencies by nose and mouth
breathing (4). The inhalable fraction (i.e., all material capable of being drawn into the
nose and mouth) is the most relevant fraction to measure.
Aerosols generated by sprayers or misters usually are mixed-phase aerosols in
which both vapor and the liquid or solid phase are present. Traditional particle-sampling devices or vapor-trapping devices (impingers, adsorbent tubes) have been used,
or these are combined to sample concurrently for particles and vapors in so-called
sampling trains. These approaches are now well documented in basic textbooks and
need no further discussion here.
Because particle sampling requires much higher flow rates, usually approx 2 L/
min, compared to vapor sampling (50 to 200 mL/min), retention of the vapors in the
vapor absorption/adsorption part may be inaccurate because of loss of material by
stripping from the adsorbent by the relatively high flow rate. To overcome such a
Postapplication Exposure Assessment
151
problem, an existing aerosol sampler that meets the criterion of inhalability has been
modified to retain vapors as well (5).
2.2. Dermal Exposure Assessment
Improved understanding of the process of dermal exposure has been achieved
through a conceptual model of dermal exposure (6) that systematically describes the
transport of contaminant mass from exposure sources to the surface of the skin. The
conceptual model describes the dermal exposure process as an event-based mass transport process resulting in “loading” of the skin (i.e., the skin contaminant layer compartment that is formed by sweat, skin oil, dead cells, and contaminants/dirt). To assess
skin loading, two major groups of methods are distinguished: direct methods, which
indicate directly how much pesticide is on the skin, and indirect methods, which provide indirect indication of potential for skin exposure.
2.2.1. Direct Methods for Dermal Exposure Sampling
Direct methods for assessing dermal exposure include methods that indicate the
mass of a contaminant or analyte that has deposited onto the skin surface over a period
of exposure. Direct methods can be grouped into three major sampling principles.
•
•
•
Collection of agent mass using collection media placed at the skin surface or replacing
work clothing during the measurement period (i.e., surrogate skin techniques).
Removal of the agent mass from the skin surface at the end of the measurement period
(i.e., removal techniques).
In situ detection of the agent or a tracer at the skin surface (e.g., through image acquisition and processing systems).
2.2.1.1. SURROGATE SKIN TECHNIQUES
Surrogate skin techniques (more precisely, interception techniques) are widely used
methods to assess dermal exposure (7,8). Basically, all methods use a collection medium onto which chemicals of interest are deposited on or transferred to by direct
contact. Reports in the literature show a variety of collection media, such as cotton,
gauze, paper, polyester, and charcoal. The ideal collection medium should mimic the
skin in terms of both collection from the environment and retention vs subsequent loss.
The collection medium is located against the skin of body parts during exposure.
After sampling, the medium is removed from the body part and transferred to the
laboratory, in which the relevant component is extracted from the medium and quantified by chemical analysis.
The size of the collection medium varies, from relatively small-size collection media located at different body parts (e.g., 10-cm2 patches) to a collection medium of the
same type covering a complete body part (i.e., whole-body garment sampling).
Surrogate sampling techniques have the advantages of relative ease of use in the
field, low capital cost, applicability for all body parts, and potential for high resolution
of exposure because the collection medium can be divided in small subsamples to be
analyzed separately and the ability to perform repeated sampling during an exposure
interval.
A general disadvantage is the need to assume that surrogate skin techniques mimic
the capture and retention properties of the skin. An additional disadvantage of small-
152
van Hemmen, van der Jagt, and Brouwer
size samplers (i.e., patches) is that the results of individual patches need to be extrapolated to the body part the patch represents.
2.2.1.2. REMOVAL TECHNIQUES
Removal techniques (i.e., removal of chemicals deposited on the skin by washing,
wiping, tape stripping) and subsequent chemical analysis of the amount of chemical
recovered from the washing solution, the wiping medium, or the adhesive strip are
used to assess dermal exposure (8). The techniques have the clear advantage of low
capital costs and ease of use; however, the use of solvents may disrupt skin barrier
function and enhance percutaneous absorption of the chemical (3). Removal of contaminants from the skin surface is accomplished by providing an external force that
equals or exceeds the force of adhesion.
For (hand) washing generally, two basic methods can be identified (9): washing
and rinsing. (Hand) washing can be defined as scrubbing the skin by mechanical agitation exercised by movement and pressure of both hands in liquid in a routine washing fashion. The contaminant is detached from the skin by a combination of mechanical
force and wet chemical action (dissolution). Tap water/soap flow or water/soap in
bags (500 mL) are commonly used methods. (Hand) rinsing or pouring can be defined
as liquid–skin contact by which the contaminant is removed by a combination of hydrodynamic drag and wet chemical action (dissolution).
Clearly, the basic distinction between both methods is the presence or absence of
mechanical forces in the process of detachment. Often, detergents are introduced in
the process to enhance the detachment of insoluble particles. Bags (250 mL for one
hand or 500 mL for two hands) are used and contain a variety of solvent with mild
irritating effects pure or in a water solution.
Identified sampling protocols for hand washing/rinsing show a reasonable similarity
of procedures. However, they deviate at possible key issues, such as amount of liquid
and duration of rinsing (bag rinsing), amount of liquid, amount of soap, duration of washing (water/soap methods). In general, removal efficiency varies between 40 and 90%
(10). Because of the limited data set on removal efficiencies and large differences in
components (related to physical properties), wash methods, and levels of loadings, no
general conclusions can be drawn on the strengths of the variables distinguished.
Skin wiping can be defined as the removal of contaminants from skin by providing
a manual external force to a medium that equals or exceeds the force of adhesion over
a defined surface area. Similar to hand washing, the contaminant is detached from the
skin by a combination of mechanical forces and wet chemical action (dissolution).
Identified sampling protocols deviate at possible key issues, such as wipe materials
and type of wiping. A wide variety of sampling media (cotton, gauzes, and sponges) is
used, dry or wet, for different surface areas of the skin. In addition, the number of
passes (i.e., the number of contacts of the wiped area with a single wipe) may vary
between 1 and 15, and the actual wiping movement may vary from a circular movement starting in the center to rectangular movements with or without use of templates.
Sampling efficiency usually is between 40 and 90% (10) and will be determined
not only by the sampling method, but also by the chemophysical properties of the
compound and wipe solvent.
Postapplication Exposure Assessment
153
Because of their ease of use and their low capital costs, the application of removal
techniques is widespread to assess dermal exposure. In spite of its potential for use for
all body parts, mostly the uncovered parts of the body are monitored. Especially for
wipe sampling, relatively high resolution of exposure per surface area can be achieved;
however, for hand washing this is not the case. Repeated sampling is possible, but the
exposure process is disturbed, and skin surfaces may be affected.
There is clear evidence that wipe sampling is less effective for removing contaminants from the skin despite the high removal efficiencies of wipe sampling reported in
one study (11). In a pesticide reentry study, Fenske et al. (12) compared hand exposure
rates determined by hand wash sampling and wipe sampling. They observed on average a sixfold lower hand exposure rate for wipe sampling compared to hand wash
sampling.
Tape stripping can be defined as the removal of stratum corneum cell layers by
(repeated) application of an adhesive tape to the skin. Tape stripping has been used for
dermatopharmacokinetic characterization of topical drug product movement into different layers of the horny layer or to assess the penetration of chemicals without the
intact barrier function of the skin. Commercially available adhesive tapes are used.
The surface area of the strips (3.8 to 10 cm2) as well as the number of strips (1 to 30)
varies between different studies.
Limited data are available that enable an evaluation of the precision, within- and
between-operator variability, and the influence of some physical sampling parameters,
such as applied pressure, adhesion time, or removal speed and angle. The data from
ref. 13 indicate a moderate variation of removal efficiency over different exposure
sites and different volunteers.
The application of the stripping method for field evaluation of dermal exposure
may be limited by analytical limits of sensitivity, but extraction of series of tapes may
overcome this problem. The need to sample a large quantity of (first) tape strips could
also be important for reasons of sampling strategy if there are heterogeneous surface
concentrations. The relatively small surface area of the tapes (typically less than 10
cm2) compared to larger surface areas that could have been contaminated may result in
similar problems in sampling strategy as for patch sampling and skin wiping.
2.2.1.3. IN SITU DETECTION TECHNIQUES
A fluorescent tracer technique to assess dermal exposure quantitatively known as
VITAE (video imaging technique for assessing dermal exposure) was introduced in
the late 1980s (14). A second-generation type of this technique was adopted by other
laboratories (15,16), whereas the basics of the technique have also been explored to
develop a novel lighting system, known as the fluorescent interactive video exposure
system (FIVES), to overcome significant problems related to quantification (17,18).
Basically, the techniques combine the introduction of a fluorescent tracer compound in the application process with image acquisition techniques. A fluorescent
tracer, selected from a wide variety of fluorescent whitening agents, deposited on the
skin is exposed to long-wave ultraviolet A (UV-A) light (320–400 nm), which activates the emission of fluorescent light by the tracer molecules. A (video) camera is
used to take and record images of the body part exposed. The amount of light emitted
154
van Hemmen, van der Jagt, and Brouwer
is detected by digitizing the analogue camera signal. The images consist of discrete
area units known as picture elements (pixels), which may have a value between 0 and
256 (gray value). Gray values of the pixels of pre- and postimages are compared to
calculate the increase of gray values resulting from exposure. A known relationship
between pixel gray levels and the amount of tracer enables calculation of exposure to
the tracer. Assuming a fixed tracer–substance ratio, the amount of tracer deposited on
the skin surface can be extrapolated to the amount of the substance of interest for
dermal exposure.
Application of fluorescent tracer techniques for dermal exposure assessment has
clear advantages compared to other direct techniques. Major strengths of these techniques are their ability to spot in situ dermal contamination on the skin surface. Absorption and retention processes that influence the results of surrogate skin sampling
or parameters affecting removal efficiency for removal techniques do not bias the
measurement. Because image acquisition is a noninvasive measurement, it does not
disturb these loading and unloading processes on the skin and enables repeated sampling within a work shift. Exposure processes can be studied relatively easily. For risk
assessment purposes, the high-resolution properties of the fluorescent tracer techniques
have a clear advantage. Because the true area exposed is detected by the system, no
estimates have to be made for the surface area exposed or the distribution of exposure
over the body part sampled. The possibility for a visual check on the distribution of
exposure over the body part that has been evaluated is helpful.
Major drawbacks of these techniques are related to the introduction of a fluorescent
tracer into the process of exposure. However, the most important limitation of these
techniques is that a tracer is detected and not the substance relevant for dermal uptake.
The premise is the similar behavior of tracer and relevant compounds during the entire
process of exposure.
Other relevant in situ determination techniques are available but hardly used routinely for pesticides; these include portable X-ray fluorescence (PXRF) (19) and
dirichlet tesselation (20).
2.2.2. Indirect Methods
2.2.2.1. SURFACE SAMPLING
Indirect methods include surface-sampling techniques and biological monitoring.
Surface sampling is relevant for an identified skin-surface contact. For reentry exposure, pesticide residues are sampled from surfaces to which workers come into contact.
The concept of dislodgeable foliar residue (DFR) (21,22), used in agriculture reentry exposure scenarios, apparently partly circumvents some of the problems related to
surface-sampling variability. This approach consists of a protocol to sample a discrete
surface area by removing (parts of) the surface (i.e., leaf portions or leaf punches are
taken from the foliage). Leaf punch samplers with punch diameters of 0.64, 1.27, and
2.54 cm are currently available that provide double-sided leaf areas of 2.5, 5.0, and 10
cm2, respectively. After sampling, the leaf portions or disks are extracted twice by
shaking at 200 strokes per min for 30 min with 100 mL distilled water per 100 cm2 leaf
surface area, containing 4 drops of a 1:50 dilution of a surfactant (e.g., Triton-X100
solution). Then, the bottle containing the leaves is rinsed with 25 mL liquid per 100
Postapplication Exposure Assessment
155
cm2 leaf surface area, and after removal of the leaves, it is rinsed again twice with 10
mL methanol/100 cm2 leaf surface area. When leaf samples are taken (instead of
punches), the leaf surface area should be determined afterward (e.g., by a light-detection-based surface area meter). Advantages of this approach compared to surface wipe
sampling are the standardized extraction procedure and person independency.
Although it is unclear how the removal procedure mimics the transfer from the
foliage surface to the worker’s skin or clothing, DFR has been used to predict dermal
exposure resulting from workers’ contact with foliage (see Subheading 3.). In refs.
23–25, pesticide residues monitored in treated fields were related to hourly dermal
exposure. The transfer coefficient (TC) has been introduced as an empirical multiplier
and usually is expressed in units of hourly dermal exposure (grams per hour) per unit
of DFR (grams per square centimeter).
2.2.2.2. BIOLOGICAL MONITORING
Biological monitoring is a method of evaluating the absorption of chemicals by
measuring the chemicals or their metabolites in body fluids, usually urine, blood, or
exhaled air. This is perceived as the principle advantage of biological monitoring over
methods of ambient exposure monitoring because the total mass of biological marker
represents the individual’s exposure from all routes of entry: inhalation, dermal, and
primary and secondary ingestion. The method requires detailed human metabolism
and pharmacokinetics data for the chemical involved for quantification (26) for an
appropriate selection of the metabolite to sample, excretion medium, and duration of
collection. Urine sampling, as a noninvasive method, is considered an ideal sampling
matrix (3), and urine collection has been practicable up to several days. Completeness
of urine voids over the full period of sampling is essential (knowledge of half-lives
needed), and no additional exposure should occur during the sampling period.
The absorbed dose, determined by biological monitoring, may be difficult to relate
to external exposure for multiple-route exposure pathways because these are very
likely to occur in pesticide exposure scenarios. However, by subtracting or eliminating
other routes of exposure, the contribution of one of the routes can be estimated in theory.
As stated, in using biological monitoring in field research of pesticide exposures, it
is important to understand the relationship between skin exposure and the biological
monitoring results. Generally, chemicals are absorbed through the skin more slowly
than through inhalation or the oral route. Also, the skin can act as a dynamic reservoir
of contaminants of past exposures, ready for mobilization and absorption under suitable conditions. Examples of these phenomena can be found in a study on exposure to
propoxur (27) (as described in Subheading 4.).
In field pesticide exposure studies, biological monitoring has been used to evaluate
and model reentry exposure (e.g., refs. 25 and 28) or to evaluate exposure reduction
by protective measures (e.g., refs. 27 and 29–31).
2.2.3. Summary and Discussion
Diverse measurement methods, partly based on different sampling principles, can
be observed. An overview for dermal exposure sampling techniques is given in
Table 1.
156
van Hemmen, van der Jagt, and Brouwer
Table 1
Overview of Measurement Methods for Dermal Exposure
Method
Sampling principle
Measured compartment
UV fluorescence of agent
or added tracer
Portable x-ray fluorescence
monitor
Wet wipe
Wet wipe
Fixed pressure dislodgeable
residue sampler
Dislodgeable foliar
residue sampling
Adhesive tape
Hand wash
In situ detection
Skin, surface
In situ detection
Surface, skin
Removal (manual wiping)
Removal (mechanized wiping)
Removal (mechanical transfer
in situ)
Removal (surface removal)
Surface, skin
Surface
Surface
Patch
Whole body
Removal (skin stripping)
Removal (wash with water
or alcohol)
Surrogate skin (passive)
Surrogate skin (passive)
Surface
Skin
Skin
Skin
Skin
It should be emphasized that all sampling methods have fundamental problems:
•
Removal methods (e.g., skin stripping and solvent washing) influence the characteristics
of the skin, limiting use for repeated sampling.
• Removal techniques (e.g., skin washing) are not appropriate for all body parts.
• Interception and retention characteristics of surrogate skin techniques differ from real
skin and might differ from the clothing. The amount recovered from the surrogate sampler does not represent the loading of the skin surface.
• Extrapolation from small areas sampled (e.g., patches, skin tape strips, or in situ detected
spots) to the entire exposed area can introduce substantial errors.
• The behavior of a (fluorescent) tracer introduced in the mass transport when using in situ
techniques may differ from the behavior of the substances of interest.
Therefore, it is recommended that these limitations be taken into account when
interpreting the sampling results, especially for risk assessment processes.
3. Exposure Modeling
On the basis of the available data on dermal exposure, attempts have been made to
develop a general approach for exposure modeling relevant for registration purposes.
This approach is based on the following steps in the process of dermal exposure: It
starts with the application of the pesticide, leading to coverage of the foliage with
pesticide residue that may or may not disappear in time because of various reasons,
such as uptake in the foliage or hydrolysis of some kind. What remains on the foliage
(DFR) may be transferred to clothing or skin of a worker who comes into contact with
the foliage. The transfer (via the transfer coefficient) will depend on the nature of the
contact and the degree of contact between body and foliage and the duration of the
work. The resulting generic model has the following algorithm:
Postapplication Exposure Assessment
Potential dermal exposure (DE) = DFR × TC × T
157
(1)
where DFR is the dislodgeable foliar residue (typically micrograms per square centimeter), TC is the transfer coefficient (typically square centimeters per hour), and T is
the time of contact (typically hours) (32). The DFR can be considered the applied
amount divided by the leaf area index (LAI):
DFR = AR/LAI
(2)
where AR is the application rate. The LAI is the ratio between the (one-sided)
foliage surface area and the ground surface area on which it grows. In these formulas,
one factor is not yet included: the dissipation (decay) of the active substance on the
foliage. This may be introduced as a factor or as a formula if the exact nature of the
dissipation over time is known. If no data are available on the degree of dissipation,
the conservative approach is to assume no dissipation between application and time of
reentry. In that case, DFR0 (at time zero) is used for calculations, that is, the residue
available directly after application (when dry).
In practice, this would mean that if no dermal exposure measurements are available, the exposure can be calculated using the relevant application rate or data or assumptions on DFR, the duration of the work activity, and information on TCs. This
requires a database on TCs, with special emphasis on the relevant scenario.
The various factors are discussed in detail in the ref. 1 on reentry exposure of the
EUROPOEM project, but the major issues involved are discussed here.
3.1. Dislodgeable Foliar Residue
The amount of residue on foliage depends on several factors, not only the application rate and droplet sizes, but also the crop type and the amount of foliage (LAI).
Moreover, dissipation of residues on crop foliage over time depends on the physical
and chemical properties of the applied active substance as well as on environmental
conditions.
Common methodologies for determination of foliar residues have been described.
Usually, a diluted surfactant in water is used for rinsing a certain leaf area, resulting
(after analysis) in an expression of residue amount per area: the DFR. It is important to
note whether the area given refers to one side or to both sides of the leaves (see Subheading 2.).
However, experimentally determined DFR data are not available in all cases. In
these cases, an estimation of the amount of DFR immediately after application can be
made by taking into account the application rate, the crop habitat (LAI), and the (possible) extent of residues remaining on foliage from previous applications (1).
3.2. Transfer Coefficient
The transfer of residues from the crop foliage to the clothes or skin of the worker
can be regarded as more or less independent of the kind of product applied, and the
level of worker exposure will depend only on the intensity of contact with the foliage.
This again is determined by the nature and duration of the maintenance activity to be
carried out during reentry.
158
van Hemmen, van der Jagt, and Brouwer
Therefore, it is advisable to group the various crop habitats and maintenance activities to reentry scenarios. Investigations to this end have been carried out, primarily in
the United States. These data are, however, of a proprietary nature. Especially, generic
transfer coefficients have been developed for a number of scenarios. Because the nature of the transfer coefficient used may depend on the data at hand (data for potential
or actual exposure, full body or only body parts), it is essential to make clear the type
of TC meant.
3.3. Exposure and Dermal Absorption
Dermal exposure (and, concomitantly, inhalation exposure) is by no means the ultimate goal of the assessment because, next to possible local effects on the skin and in
the airways, the active substance must enter the body for systemic health effects. This
requires absorption through the skin. Although the end point for the current report is
exposure assessment and not risk assessment, it is worthwhile to indicate the relevance
of knowledge on absorption and the possible validation of the use of data on dermal
exposure and dermal absorption. In the next section, the use of biological monitoring
for estimation of uptake in the human body is discussed in more detail.
3.3.1. Using the Generic Model
Equation (1) is applicable, using the database on TCs, when measured DFR values
are available. In most cases, especially when developing a new product, these data are
not available at an early stage. For the estimation of worker exposure at that stage, an
extended version of the formula together with a tiered approach can be used. The TC is
assumed to be relatively pesticide independent and crop and task specific. However,
between-crops and task variances of the TC may be substantial (33,34). In ref. 1,
several generic values for TCs are given related to specific use scenarios.
3.3.2. Tiered Approach to Risk Assessment for Reentry Workers
If use conditions are relevant to reentry exposure, a tiered approach to risk assessment is proposed (1). Adopting a tiered approach allows flexibility in the assessment
procedure. Although tier 1 uses only generic data and assumptions, the demand for
further and more specific information increases with each successive tier. Accordingly, information and assessments become less general (i.e., more refined and specific to the situations under consideration, as described below).
Comparing the estimated exposure value at any tier level with the AOEL (acceptable operator exposure level, which is applicable also to the reentry worker) may demonstrate an acceptable risk, leading to a regulatory decision to authorize the product.
On the other hand, failure to demonstrate an acceptable risk takes the assessment to
the next tier, which demands more exact input data. The general form of this tiered
approach is depicted in words in Table 2.
3.4. Estimation of Inhalation Exposure
The description of the generic model and the tiered approach reflects only dermal
exposure, not inhalation exposure. Although in many cases inhalation exposure will
be less important for the risk assessment than dermal exposure, some emphasis must
Postapplication Exposure Assessment
159
Table 2
Tiered Approach for Assessment of Reentry Exposure
Tier 1
Tier 2
Tier 3
Tier 4
Uses the generic assumption on initial DFR and database for transfer factors
to give single conservative point estimates (surrogate values) for total
potential exposure, fully exploiting the capacity of the database applicable
to a broad range of reentry scenarios common to European conditions.
If the estimated reentry exposure is within the AOEL, no further action
is required and approval can be granted.
Uses the generic database plus additional information relating to exposuremitigating factors (i.e., exposure reduction coefficients for personal protective
equipment [PPE]) pertinent to the case. This offers a middle course in which
supplementary use-specific information is used to refine the exposure
estimation, thus reducing uncertainty.
If the estimated reentry exposure, including defined specific instructions
on worker exposure, is within the AOEL, no further action is required,
and approval can be granted.
Uses additional data on product-specific percutaneous absorption and on DFRs
and their dissipation curves from foliar dislodgeable residue studies under
actual conditions of use.
If the estimated reentry exposure, including the redefined specific instructions
on worker exposure (if necessary), is within the AOEL, no further action
is required, and approval can be granted.
Uses product-specific data from biological monitoring studies or reentry
exposure studies on the active substance under consideration and the actual
reentry conditions. This provides absolute exposure data and places
the greatest demands on the quality and relevance of data required.
If the measured reentry exposure, including the redefined specific instructions
(if necessary) on worker exposure, is within the AOEL, no further action
is required, and approval can be granted.
If the measured reentry exposure exceeds the AOEL, reentry restrictions
have to be established.
be given to inhalation exposure. For the few available data, an algorithm is given for
some reentry scenarios based on the active substance (as):
mg as/h inhaled = kg/as/ha applied × Task-specific factor
The task-specific factors, which can be used in the first tier of the exposure and risk
assessment, have been estimated for a small set of exposure data on harvesting of
ornamentals and reentry of greenhouses about 8–16 h after specific applications. Some
task-specific factors are given in ref. 1.
In many cases, inhalation exposure is expected to be quite low in comparison with
dermal exposures, of course with exceptions for situations for which aerosols and volatile pesticides are of concern.
Inhalation exposure may be not only to vapors, but also to dusts. The relevance of
soil exposure to inhalation contamination with pesticides is also covered in ref. 1,
160
van Hemmen, van der Jagt, and Brouwer
with a possible approach to estimating this whenever considered relevant. Generally,
contaminated soil exposure will be relatively low compared to other exposures. The
case of possible dermal exposure to soil containing pesticide residues is treated using
the concept of dermal adherence.
4. Relevance of Methodology for Internal Exposure Assessment
The TC concept (as described in Subheading 3.) and the acceptance of its validity
are essential for the credibility and acceptance of a database of reentry exposure and
generic TCs for predicting reentry worker exposure. The concept has never been validated in terms of its ability to predict dermal exposure when used in conjunction with
compound-specific DFR data. Biological monitoring is recognized for giving the most
accurate estimate of the absorbed dose of a pesticide, particularly if studies are
designed and interpreted with the aid of human metabolism and pharmacokinetic data.
A direct comparison of the passive dosimetry and biological monitoring approaches to
the estimation of the absorbed dose would go a long way to providing the necessary
confidence in the TC concept’s validity.
Biological monitoring can also provide a good estimate of the uptake of a compound over a day’s work, considering the work process, use scenario, any measures
used for mitigation of exposure (control by engineering measures, personal protective
equipment [PPE], personal hygiene, etc.). In field practice, it therefore has the advantage of including all exposure pathways. Furthermore, using biological monitoring
has the advantage that additional factors in skin penetration under specific conditions
of protective clothing can be included in the interpretation of results, a scenario not
allowed by measurement of external potential or actual exposure.
The evaluation of protective clothing is a major reason for doing intervention type
of studies (“as is” and with a specific PPE regime) for which biological monitoring is
the gold standard for assessing the internal exposure. The main reason for studying the
internal exposure levels is that these levels are the most relevant for risk assessments;
that is, they are much better than external exposure levels corrected for clothing protection and taking percutaneous absorption into account, as is currently done for registration procedures.
De Vreede et al. (35) reported large variations in penetration of work clothing (from
a few percentage up to 30% for methomyl in operators, depending on location on the
body and on exposure levels). This indicates the importance of more detailed studies,
which have been carried out for some specific conditions (2). An intervention study
has been carried out for pest control operators using custom personal protection for the
pesticide chlorpyrifos (36).
For reentry conditions, the intervention type of study, using biological monitoring,
is seldom used, mainly because the study design is difficult, and the costs for such a
study are very high. In the Netherlands, such a study has been carried out for the
harvesting of carnations in greenhouses.
4.1. Greenhouse Reentry Example
An intervention study was carried out to evaluate the effectiveness of protective
clothing on the reduction of dermal exposure for the pesticide propoxur under field
Postapplication Exposure Assessment
161
conditions during application and postapplication harvesting of carnations (37). The
study was carried out in different greenhouses in the Netherlands (a relatively controlled environment). Both exposure of the hands and inhalation were measured for
applicators and harvesters for different protective clothing scenarios. The study was
carried out as an intervention study (normal working conditions), with a normal clothing scenario prior to the intervention and with additional protective clothing after the
intervention.
Both potential and actual exposure were assessed using the whole body technique
(3). Potential exposure to the hands was measured using monitoring gloves.
Postintervention, actual exposure to the hands was assessed for 18 harvesters following reentry. Hand exposure was assessed using hand washes; the rinse-off water was
collected and analyzed after two hand washes. Respiratory exposure was assessed using an Institute of Occupational Medicine, Edinburgh, UK (IOM) sampler. To assess
propoxur absorption, biological monitoring was carried out. A dose excretion study
(38) using volunteers indicated a significant increase in the dermal uptake of the active
ingredient under occlusion conditions, signifying increased blood flow, a rise in skin
temperature, and skin moisture. The relevance of skin moisture was identified (39). In
the study by Brouwer et al. (37), skin moisture was monitored on various locations on
the body.
Biological monitoring was interpreted by assessing the total amount of 2isopropoxy-phenol (IPP) (metabolite of propoxur) excreted in the urine. Volunteer
studies revealed a one-to-one relationship to absorbed propoxur and excreted IPP. A
pulmonary retention of 40% was found (40) and used to calculate the relative contribution of respiratory exposure to the internal dose. For dermal exposure, the calculated respiratory portion was subtracted from the total amount of IPP. The study found
that the amount of IPP excreted after working with normal clothing was 83–2189 nmol
propoxur and with protective clothing was significantly reduced from 16 to 917 nmol
for harvesters for similar external exposure patterns. It was also shown that all body
parts except the palms of the hands revealed higher skin moisture during the use of
protective clothing.
To enable the interpretation of biological monitoring, some very specific information had to be available. Information on the excretion pattern (e.g., to allow for proper
data collection), the absorption rate through the different exposure pathways (respiratory, oral, and dermal) and the relationship between the excreted amount and the initial dose must be known. PBPK studies provide some of this information, but they are
not readily available for most chemicals. Also, as shown in refs. 37 and 39, the excretion of metabolite can be affected by the influence of other factors on absorption into
the body (e.g., occlusion), complicating the interpretation of the contribution from the
different exposure routes and requiring more data.
The data obtained in the study compared reasonably well with other similar studies
(as indicated in ref. 37). This may indicate the value of the data for reentry exposure.
The apparent relatively small reduction in internal exposures, even after correction for
the small contribution of inhalation exposure seems to indicate that the typical modeling approach for registration purposes may be overly conservative when using only external exposure data.
162
van Hemmen, van der Jagt, and Brouwer
Acknowledgments
We thank the Dutch Ministry of Social Affairs and Employment for their financial
support of the experimental work in assessing exposure during pesticide application
and postapplication activities, which made the writing of this chapter possible. We
would also like to thank our colleagues at TNO Chemistry for their support and, most
important, the colleagues in the EUROPOEM project, with whom the many discussions on the issues involved have sharpened our approaches and views and made this
work possible. Many discussions with international colleagues from competent
authorities and agrochemical industry at workshops and conferences have also largely
contributed to the present state of the art of the postapplication exposure assessment
and modeling and their use in risk assessment for registration purposes.
References
1. EUROPOEM. (2003) Post-application Exposure of Workers to Pesticides in Agriculture.
Report of the Re-entry Working group, EUROPOEM II Project (FAIR3-CT96-1406),
TNO-BIBRA, Carshalton, UK.
2. Van Hemmen, J. J., Brouwer, D. H., and De Cock, J. S. (2001) Greenhouse and mushroom
house exposure, in Handbook of Pesticide Toxicology. Volume I. Principles (Krieger, R.
I., ed.), Academic Press, New York, pp. 457–478.
3. Organisation for Economic Co-operation and Development. (1997) Guidance Document for
the Conduct of Studies of Occupational Exposure to Pesticides During Agricultural Application, OECD Environmental Health and Safety Publications Series on Testing and Assessment, no. 9, Organisation for Economic Co-operation and Development, Paris, France.
4. CEN EN 481. (1993) Workplace Atmospheres. Size Fraction Definitions for Measurement
of Airborne Particles, European Committee for Standardization, Brussels, Belgium.
5. Brouwer, D. H., Ravensberg, J. C., De Kort, W. L. A. M., and Van Hemmen, J. J. (1994).
A personal sampler for inhalable mixed-phase aerosols. Modification to an existing sampler and validation test with three pesticides, Chemosphere 28, 1135–1146.
6. Schneider, T., Vermeulen, R., Brouwer, D. H., Cherrie, J. W., Kromhout, H., and Fogh, C.
L. (1999) Conceptual model for assessment of dermal exposure. Occup. Environ. Med. 56,
765–773.
7. Soutar, A., Semple, S., Aitken, R. J., amd Robertson, A. (200) Use of patches and whole
body sampling for the assessment of dermal exposure. Ann. Occup. Hyg. 44, 511–518.
8. Brouwer, D. H. (2002) Assessment of Occupational Exposure to Pesticides in Dutch Bulb
Culture and Glasshouse Horticulture, PhD thesis, Utrecht University, Zeist, The Netherlands.
9. Brouwer, D. H., Boeniger, M. F., and Van Hemmen, J. J. (2000) Hand wash and manual
skin wipes. Ann. Occup. Hyg. 44, 501–510.
10. Marquart, J., Brouwer, D. H., and Van Hemmen, J. J. (2002) Removing pesticides from
the hands with a simple washing procedure using soap and water. J. Occup. Environ. Med.
44, 1075–1082.
11. Geno, P. W., Camann, D. E., Harding, H. J., Villalobos, K., and Lewis, R. G. (1996)
Handwipe sampling and analysis procedure for the measurement of dermal contact with
pesticides. Arch. Environ. Contam. Toxicol. 30, 132–138.
12. Fenske, R. A., Simcox, N. J., Camp, J. E., and Hines, C. J. (1999) Comparison of three
methods for assessment of hand exposure to Azinphos-Methyl (Guthion) during apple
tinning. Appl. Occup. Environ. Hyg. 14, 618–623.
Postapplication Exposure Assessment
163
13. Surakka, J., Johnsson, S., Lindh, T., Rosén, G., and Fischer, T. (1999) A method for measuring dermal exposure to multifunctional acrylates. J. Environ. Monit. 1, 533–540.
14. Fenske, R. A., Leffingwell, J. T., and Spear, R. C. (1986) A video imaging technique for
assessing dermal exposure. I. Instrument design and testing. Am. Ind. Hyg. Assoc. J. 47,
764–770.
15. Archibald, B. A., Solomon, K. R., and Stephenson, G. R. (1994) A new procedure for
calibration the video imaging technique for assessing dermal exposure to pesticides. Arch.
Environ. Contam. Toxicol. 26, 398–402.
16. Bierman, E. P. B., Brouwer, D. H., and Van Hemmen, J. J. (1998) Implementation and
evaluation of the fluorescent tracer technique in greenhouse exposure studies. Ann. Occup.
Hyg. 42, 467–475.
17. Roff, M. W. (1994) A novel illumination system for the measurement of dermal exposure
using a fluorescent dye and image processor. Ann. Occup. Hyg. 38, 903–919.
18. Roff, M. W. (1997) Accuracy and reproducibility of calibrations on the skin using the
FIVES fluorescence monitor. Ann. Occup. Hyg. 41, 313–324.
19. Dost, A. A. (1995) Monitoring surface and airborne inorganic contamination in the workplace by a field portable x-ray fluorescence spectrometer. Ann. Occup. Hyg. 40, 589–610.
20. Wheeler, J. P. and Warren, N. D. (2002) A dirichlet tessellation-based sampling scheme
for measuring whole-body exposure. Ann. Occup. Hyg. 46, 209–217.
21. Gunther, F. A., Barkley, J. H., and Westlake, W. E. (1974) Work environment research II.
Sampling and processing techniques for determining dislodgeable pesticides residues on
leaf surfaces. Bull. Environ. Contam. Toxicol. 12, 641–644.
22. Iwata, Y., Knaak, J. B., Spear, R. C., and Foster, R. J. (1977) Worker re-entry into pesticide-treated crops: I Procedure for the determination of dislodgeable residues on foliage.
Bull. Environ. Contam. Toxicol. 10, 649–655.
23. Nigg, H. N., Stamper, J. H., and Queen, R. M. (1984) The development and use of a
universal model to predict tree crop harvesters pesticide exposure. Am. Ind. Hyg. Assoc. J.
45, 182–186.
24. Zweig, G., Leffingwell, J. T., and Popendorf, W. J. (1985) The relationship between dermal pesticide exposure by fruit harvesters and dislodgeable residues. J. Environ. Sci.
Health B20, 25–59.
25. Popendorf, W. J. and Leffingwell, J. T. (1982) Regulating organophosphate residues for
worker protection. Residue Rev. 82, 125–201.
26, Woollen, B. H. (1993) Biological monitoring for pesticide absorption. Ann. Occup. Hyg.
37, 525–540.
27. Brouwer, R., Van Maarleveld, K., Ravensberg, L., Meuling, W., De Kort, W. L. A. M.,
and Van Hemmen, J. J. (1993) Skin contamination, airborne concentrations, and urinary
metabolite excretion of propoxur during harvesting of flowers in greenhouses. Am. J.
Indust. Med. 24, 593–603.
28. Popendorf, W. J. (1992) Re-entry field data and conclusions. Rev. Environ. Contam.
Toxicol. 128, 71–117.
29. Maddy, K. T., Krieger, R. I., O’Connel, L., et al. (1989) Use of biological monitoring data
from pesticide users in making pesticide regulatory decisions in California. Study of captan exposure of strawberry picker, in Biological Monitoring for Pesticide Exposure (Wang,
R. G. M., Franklin, R. C., Honeycutt, R. C., and Reinert, J. C., eds.), ACS Symposium
Series no. 282, American Chemical Society, Washington, DC, pp. 338–353.
164
van Hemmen, van der Jagt, and Brouwer
30. Chester, G., Dick, J., Loftus, N. J., Woollen, B. H., and Anema, B. H. (1990) The effectiveness of protective gloves in reducing dermal exposure to, and absorption of, the herbicide fluazifop-p-butyl by mixer-loader-applicators using tractor sprayers, in Proceedings
of the Seventh International Congress of Pesticide Chemistry, IUPAC, New York, Vol. 3,
p. 378.
31. Aprea, C., Sciarra, A., Sartorelli, P., Desideri, E., Amati, R., and Satorelli, E. (1994) Biological monitoring of exposure to organophosphorous insecticides by assay of urinary
alkylphosphates: Influence of protective measures during manual operations with treated
plants. Int. Arch. Occup. Environ. Health 66, 333–338.
32. Van Hemmen, J. J., Van Golstein Brouwers, Y. G. C., and Brouwer, D. H. (1995) Pesticide exposure and re-entry in agriculture, in Methods of Pesticide Exposure Assessment
(Curry, P. B., Iyengar, S., Maloney, P. A., and Maroni, M., eds.), Plenum Press, New
York, pp. 9–19.
33. Krieger, R. I., Blewett, C., Edmiston, S., et al. (1991) Gauging pesticide exposure of handlers (mixer/loaders/applicators) and harvesters in California agriculture. Med. Lavoro
81, 474–479.
34. Brouwer, D. H., De Haan, M., and Van Hemmen, J. J. (2000) Modelling re-entry exposure
estimates. Application techniques and –rates, in Worker Exposure to Agrochemicals. Methods for Monitoring and Assessment (Honeycutt, R. C., and Day, E. W., Jr., eds.), Lewis,
Washington, DC, pp. 119–138.
35. De Vreede, J. A. F., De Haan, M., Brouwer, D. H., et al. (1996) Exposure to Pesticides.
Part IV. Application to Chrysanthemums in Greenhouses, Report S131-4, Ministry of
Social Affairs and Employment, The Hague, The Netherlands.
36. Van der Jagt, K. E., Tielemans, E., Links, I., Brouwer, D., and Van Hemmen, J. (2004)
Effectiveness of personal protective equipment: relevance of dermal and inhalation exposure to chlorpyrifos among pest control operators. Am. Ind. Hyg. Assoc. J. in press.
37. Brouwer, D. H., De Vreede, J. A. F., Meuling, W. J. A., and Van Hemmen, J. J. (2000)
Determination of the efficiency for pesticide exposure reduction with protective clothing:
a field study using biological monitoring, in Worker Exposure to Agrochemicals. Methods
for Monitoring and Assessment (Honeycutt, R. C., and Day, E. W., Jr., eds.), Lewis, Washington, DC, pp. 63–84.
38. Meuling, W. J. A., Bragt, P. C., Leenheers, L. H., and De Kort, W. L. A. M. (1991) Doseexcretion study with the insecticide propoxur in volunteers, in Prediction of Percutaneous
Penetration Methods. Methods, Measurements and Modelling (Scott, R. C., Guy, R. H.,
Hagraft, J., Bodde, H. E., eds.), IBC Technical Services, London, Vol. 2, pp. 13–19.
39. Meuling, W. J. A., Franssen, A. C., Brouwer, D. H., and Van Hemmen, J. J. (1997) The
influence of skin moisture on the dermal absorption of propoxur in human volunteers: a
consideration for biological monitoring practices. Sci. Total Environ. 199, 165–172.
40. Machemer, L., Eben, A., and Kimmerle, G. (1982) Monitoring of propoxur exposure, Stud.
Environ. Sci. 18, 255–262.
Bystander Exposure to Pesticides
165
13
Field Study Methods for the Determination
of Bystander Exposure to Pesticides
C. Richard Glass
Summary
Techniques to estimate bystander exposure are described. Passive sample media such
as filter paper are used to collect spray drift. Air-sampling devices are used to determine
the airborne concentration of pesticides. The use of a mannequin or volunteer dressed in
a disposable coverall standing downwind of the treated zone gives the most accurate
indication of the potential dermal exposure of a bystander.
Key Words: Bystander; exposure; field study; pesticides.
1. Introduction
The proximity of many rural populations to agriculture has brought about increased
awareness of the potential for exposure of bystanders to pesticides as particulates and
vapor fractions following the application of pesticides in both the open air and enclosed areas. In this context, a bystander can be described as someone who may be at
risk of exposure to pesticide drift but who is not involved with the application process
itself. Therefore, the bystander is not protected from dermal or inhalation exposure
and is often not even aware of the pesticide application.
Techniques to estimate bystander exposure are similar to those used to measure
spray drift (1,2) and involve the location of sampling media at distances between the
application area itself and sites downwind of this area here there is the potential for
bystanders to be present. Passive sample media such as filter paper collect spray drift
that sediments onto the ground, with cylindrical lines such as fishing line or fine
polythene tubing collecting the airborne fraction. Air sampling devices can also be
used to determine the airborne concentration of pesticides. The use of a mannequin or
volunteer dressed in a disposable coverall standing downwind of the treated zone gives
the most accurate indication of the potential dermal exposure of a bystander because
the collection of airborne droplets is determined by factors such as the airflow around
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
165
166
Glass
the collector and the momentum of the droplets. Such mathematical reasoning is well
documented (3) and does not require further explanation here.
2. Materials
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Petri dishes with lids.
Filter paper.
Chromatography paper (5-cm diameter).
Fishing line, strings, or Portex 2-mm diameter polythene tubing.
Disposable coveralls (e.g., Tyvek, Kimberly-Clark, Sontara).
Air-sampling pumps (2-L/min flow rate).
Institute of Occupational Medicine (IOM) sampling head/sorbent tubes (e.g. XAD-2).
Anemometer.
Wind vane.
Thermometer (wet and dry bulb).
Mannequins or human volunteers.
Suitable crop and sprayer.
Pesticide or tracer.
Measuring cylinders.
Stopwatch.
3. Methods
The methods described below outline (1) the selection of the field site for the study,
(2) the selection and calibration of spraying equipment and pesticide, (3) the location
of sampling media and devices, (4) measurements during the application of the pesticide, (5) labeling and storage of the sample media, and (6) expression of the data.
3.1. Field Site Selection
There is a wide range of field studies that could be done to determine potential
bystander exposure. Field studies can be set up in fields that allow easy sampling of
the spray drift, although these may not be situations in which bystander exposure is
likely to occur. Alternatively, studies can be done at specific locations that may be
representative of actual bystander exposure scenarios, such as sites where there are
dwellings or footpaths adjacent to fields or crops that are sprayed with pesticides.
Typical scenarios could be as follows:
1. Areas adjacent to an arable field of winter wheat with a height of 70–100 cm, for which a
late fungicide or insecticide treatment is made with a boom sprayer fitted with hydraulic
nozzles.
2. Areas adjacent to a top fruit orchard, such as for apples, with a tree height of 3m and for
which a fungicide or insecticide treatment is made with an axial fan orchard air blast
sprayer fitted with hydraulic nozzles.
3. Areas adjacent to a semiopen greenhouse with a tomato crop 2 m high for which a fungicide or insecticide treatment is made with a handheld lance with hydraulic nozzles.
There are many more scenarios that could involve the application of granules to the
soil surface or gases injected into the soil. In some cases, the vapor and particulates
from the pesticide application may travel several kilometers (4,5).
Bystander Exposure to Pesticides
167
However, unless a specific situation needs to be investigated, it is advised that initial studies be done in areas where the topography is uniform and flat and there are few
obstructions such as hedges, trees, or buildings. Such structures can interfere with
both wind speed and wind direction and cause eddies in the air around the field. Such
changes to the air movement may result in lack of deposition of pesticide drift in the
areas where collection media have been placed. If there are doubts about the suitability of a field site, the use of a smoke generator or pellets can give a useful indication of
the air currents. The field and surrounding area need to be large enough to allow the
study to be set up as described in Subheading 3.3.4.
The type of crop used for the field study is important because this will determine
the boom height for typical arable sprayers and as such the release height of the pesticide from the nozzle. The filtering effects of the crop will also influence the amount of
drift. For many temperate regions of the world, a mature crop such as wheat with a
height of approx 0.7 m represents a typical scenario of agricultural land that may be
adjacent to dwellings. Such crops need to be treated with a pesticide in the form of a
liquid using a boom sprayer. However, taller crops such as apples or oilseed rape
(canola) are likely to result in higher levels of bystander exposure because of greater
crop height or upward application technique in the case of orchard crops. For tree and
bush crops, the height of the crop and the density of the foliage will affect the amount
of spray drift.
3.2. Spraying Equipment and Pesticide
When a field study is planned specifically to generate data for bystander exposure,
it is important to consider the type of pesticide application equipment used. For the
typical bystander exposure scenario referred to in Subheading 3.1., this would be the
arable situation, with the pesticide applied to the crop using a mounted, trailed, or selfpropelled boom sprayer with hydraulic nozzles. The amount of bystander exposure is
considered closely related to the amount of airborne and ground-deposited spray drift
(6). The application technique, nozzles used, and operating pressure will affect the
amount of spray drift, which has been documented by a number of authors (7,8). The
pesticide used for the study also needs to be considered carefully because the volatility
of the active substance in the pesticide product will affect the airborne levels in the
period following the application. The selected pesticide must also be known to be
recoverable from the sampling media used for the study, as described in Subheading 3.3.
An alternative to using a pesticide is to use a tracer such as a food color (e.g., Green
S) or a fluorescent tracer (e.g., fluorescein). A tracer cannot provide data for exposure
to the volatile fraction but can be used for exposure to the particulates (droplets) for
short-term bystander exposure studies. Tracers are usually much cheaper and easier to
analyze than pesticides, although some fluorescent tracers can be unstable in strong
sunlight. Tracers also are advantageous because they are nonhazardous, making the
fieldwork easier by reducing the need for protective clothing. When tracers are used,
they should be tank mixed with an appropriate surfactant to give the spray liquid a
surface tension similar to diluted pesticide formulations. Surface tension is known to
affect the droplet production by nozzles, especially twin fluid nozzles.
168
Glass
3.2.1. Selection of Application Equipment
Once the crop and application technique have been selected, the type of application
equipment (sprayer) should be chosen. This is not as critical as the selection of the
application technique and is often determined by the availability of sprayers on the
farms available for the field study. Some of the key factors to consider are the following:
1. Boom width, which should be either 12 or 24 m to be representative of the most common
widths found on arable farms.
2. The boom suspension type because this will affect the boom stability. This is a key factor
because on uneven or rutted fields the movement of the boom causes uneven application
because of yawing. Rolling of the boom results in nozzles on the boom that are not at the
correct height above the crop.
3. Boom height. Arable field studies tend to be done with the boom 50 cm above the crop if
110° flat-fan nozzles are used, as described in Subheading 3.2.2.
4. If orchard crops are used for the study, an appropriate sprayer should be used that is
typically used locally.
3.2.2. Nozzle Selection
In northern Europe, most arable sprayers are fitted with 110° flat-fan hydraulic
nozzles. In some countries, such as Argentina (9), 80° flat-fan nozzles are more commonly used. It is advisable to use nozzles that are typical for the region where the
study is done or for the region where the data are to be used. During the late 1990s, a
number of new nozzle types were introduced onto the market in Europe. Twin fluid
nozzles have been available for some time; air and water are mixed under pressure to
produce droplets containing air. There are now low-drift nozzles that have a Venturi
system and others that have a preorifice mixing chamber. Such nozzles result in less
drift during the application by reducing the number of droplets smaller than 100 µm.
Therefore, it is important to select a nozzle appropriate to the local conditions under
study or the conditions for which the data are generated.
Alternative nozzle types used on application equipment include hollow-cone and
solid-cone nozzles. There are also spinning disks, often described as controlled droplet application.
3.2.3. Calibration of Application Equipment
The application equipment used in field studies must be calibrated to ensure that
the rate of application of the pesticide is known. The application equipment will have
user manuals that describe how the calibration should be done. This is often a simple
process that for arable sprayers involves measuring the output of liquid from selected
nozzles at the pressure intended to be used for the application (usually between 2 and
4 bar pressure). The pressure indicated on the pressure gage may not be accurate, so it
is advisable to consult the nozzle manufacturer’s recommendations. It is better to set
the pressure to give the nozzle output recommended in the manufacturer’s literature
because the pressure gages on farm equipment can have large errors. Record all details
of the calibration in the field record book for referral when the equipment is prepared
for the application in the field, as described in Subheading 3.3.
Bystander Exposure to Pesticides
169
Fig. 1. Field deployment for two types of ground deposit media.
3.3. Preparation and Deployment of Sampling Media
All media used for the study must be evaluated in the laboratory prior to the commencement of the fieldwork. Simple triplicate fortifications (spiking) with diluted
samples of the selected pesticide formulation for each media type to be used can determine the recovery of the active substance. This ensures that the field samples will
allow the pesticide to be extracted for analysis. Certain pesticides are difficult to extract
from material such as polythene or cotton. The stability and recovery of the pesticide
should be determined over the period of time the samples are expected to be stored
between the fieldwork and analysis.
3.3.1. Sampling Media for Ground Fallout of Spray Drift
One of the methods used to estimate bystander exposure is to measure the amount
of pesticide spray drift deposited on the ground. This type of media is usually filter
paper or similar media (e.g., Benchkote), which is laid out on the ground or on supports such as wood or petri dishes. Typical media used with tracer studies are shown in
Fig. 1.
3.3.2. Sampling Media for Airborne Pesticides
There are both active and passive collectors that can be used to measure airborne
pesticides. The vertical drift profile should be measured at two distances from the
edge of the swath using collection media such as 2-mm diameter Portex fine-bore
polythene line. The lines can be suspended horizontally or vertically across 0.5-m
170
Glass
Fig. 2. A field layout for a bystander exposure study.
wooden frames at 0.25-m intervals from 0.25 to 1.75 m above ground level. Two bystanders, wearing hooded absorbent coveralls as collection media, stand at the same
positions as the line frames. A diagrammatic representation of the field layout is given
in Fig. 2. When vertical lines are deployed, it is normal practice to collect the spray
drift up to a height of 10 m above the ground because this complies with the latest
International Organization for Standardization draft protocol for spray drift measurement in the field (10,11).
For active sampling of airborne pesticides, personal air samplers are used. These
can be connected to samplers such as the IOM head or sorbent tubes such as XAD-2
(12). These samples should be placed at heights above the ground representing the
normal breathing zone (i.e., 1.5–2 m for adults, although this could be 0.5 m for children). It is normal practice to attach the sample head to the lapel of the mannequin or
human volunteer. The flow rate of air through the sampler should be set according to
manufacturer’s recommendations for the particular sample head or absorbent tube used.
3.3.3. Sampling Using Mannequins or Volunteers
Life-size mannequins can be dressed in disposable coveralls such as Tyvek Classic
or Kimberly-Clark Kleenguard and positioned downwind of the application area close
to other sampling media such as the polythene lines. Alternatively, if the study is done
with nonhazardous tracer, human volunteer bystanders wearing the hooded coveralls
can stand at the same positions as the frames with polythene lines as described in
Subheading 3.3.2. and illustrated in Fig. 3. This method of sampling will give an
Bystander Exposure to Pesticides
171
Fig. 3. Typical field study showing bystander volunteer downwind of tracer application.
indication of the pesticide likely to be deposited on the whole body surface of a person. The coverall can be cut into sections to identify which areas of the body received
the most contamination.
3.3.4. Location of Sampling Media in the Field
It is advisable to position a range of sampling media to cover an area of crop and
adjacent land that includes sampling media for deposited pesticide within the application area and an area downwind of the application to a distance of at least one boom
width from the edge of the treated crop. A typical field layout for an arable crop situation is shown in Fig. 2. The distances sampled from the application area depend on
the type of the study and the expected levels of spray or vapor drift.
3.4. Monitoring of the Pesticide Application
Once the application equipment has been calibrated and set up for the field study,
there are a number of critical observations and recordings that should be made. The
application of the pesticide (or tracer) and the interaction with the prevailing wind
conditions are the factors that have greatest influence on the bystander exposure data
generated.
3.4.1. Pesticide Application Parameters
Details of the pesticide application are observed and recorded with a photographic
record advisable to allow rapid recording of visual information. Digital photographs
or videos provide a useful source of information that can be used to provide answers to
172
Glass
questions that may arise during the analysis of the data. The following is a list of
essential data that should be recorded.
1.
2.
3.
4.
Start time for application.
End time for application.
Area of crop treated (particularly the number of sprayer passes for the sampling media).
Observations during the mixing and loading procedure to ensure that the volume of pesticide formulation added to the spray tank is correct and recorded.
5. The ground speed of the sprayer. This can be done by recording the time taken to travel a
measured distance (e.g., 100 m). For example,
Ground speed = Distance/Time
If it takes 44 s to travel 100 m, then the speed is 100/44 = 2.3 m/s. To convert from ms–1
to km/h, multiply by 3.6. To convert from m/s to mph multiply, by 5.11.
6. Record all details for the application equipment and settings. The list should include the
following:
a.
b.
c.
d.
e.
f.
g.
h.
i.
Manufacturer and model of the application equipment.
Spray tank size.
Boom width and height above crop and ground.
Nozzle number and type (manufacturer’s marking).
Working pressure (taken from pressure gage),
Flow rate for a minimum of three nozzles with clean water.
Volumes of water and pesticide added to spray tank.
Estimate of volume left following application.
Application rate (liters of water per hectare or gallons per acre).
7. Details of the crop need to be recorded, including crop type, height, and growth stage
(with estimate of leaf area index if appropriate). Light detection and ranging (LIDAR) is
becoming commonly used now for tree and bush crops to determine dose rates based on
amount of foliage (13).
3.4.2. Meteorological Conditions
It is essential to record the ambient conditions for the duration of the field study. It
is recommended that data are collected at two heights above ground, with one of the
heights boom (spray release) height in the case of arable sprayers. The following data
should be collected:
1.
2.
3.
4.
Temperature.
Relative humidity.
Wind speed.
Wind direction.
The use of a data logger can allow these measurements to be taken at frequent
intervals over a long period.
3.5. Collection and Storage of Media
3.5.1. Time of Collection
The media placed in the field for the field trial can be collected shortly after the end
of the pesticide application because the liquid droplets dry quickly on all media types.
Bystander Exposure to Pesticides
173
In warm and sunny conditions, the pesticide may begin to degrade, so the media should
be collected as soon as possible. This also minimizes problems with contamination
from other sources in the field.
3.5.2. Method of Collection
Scientific staff collecting the media should wear disposable gloves to avoid cross
contamination of samples. Scientists who have been involved with handling of the
pesticide, either diluted or the concentrate, should not be involved with handling field
samples because of the risks of cross contamination. Samples should always be collected such that those expected to have the lowest residues (i.e., those furthest away
from the application area) are collected first. The samples can be collected in a number
of ways, depending on the nature of the sample.
The information can be written onto the label in the field or can be printed on selfadhesive labels, which can be taken to the field. The field samples should be collected
in the following order: air samplers, mannequin coveralls, Benchkote, and petri dishes.
3.5.2.1. AIR SAMPLERS
1.
2.
3.
4.
Switch off the sampling pumps.
Remove IOM sample heads or absorbent tubes (e.g., XAD-2) from the mannequins.
Remove the cassette containing the filter and secure with seal.
Place in a labeled polythene bag.
3.5.2.2. MANNEQUIN COVERALLS
1. Remove the mannequin (or volunteer) to a clean area of the field and place on a sheet of
polythene on the ground.
2. Remove the coverall from the mannequin, avoiding cross contamination between areas of
the coverall.
3. If the coverall is to be sectioned, this can be done in the field with a clean pair of scissors.
4. Place each of the sections or the whole coverall in a labeled polythene bag.
3.5.2.3. BENCHKOTE (OR SIMILAR FLAT MEDIA PLACED ON GROUND)
1. Starting with the media samples furthest from the application area, carefully roll or fold
the sections of Benchkote and place in labeled polythene bags.
2. When the collection media is fixed by staples or a similar mechanism, care needs to be
taken when removing the media from the support so the media does not tear, which may
result in lost pieces.
a. Collect the media from within the application area last because this is the most heavily
contaminated.
3.5.2.4. PETRI DISHES
1. Starting with the petri dishes furthest from the application area, place clean lids on each
and fix the lid with adhesive tape.
2. Label each petri dish.
3. Collect the petri dishes in sets of 5 or 10 and bind together with adhesive tape so that they
can be kept in order.
4. Place in clean polythene bags.
5. Collect the petri dishes from within the application area last because this is the most
heavily contaminated.
174
Glass
3.5.3. Labeling of Media
Each individual piece of collection media needs to have a unique label, so that it
can be readily identified, should it be separated from the rest of the samples during
transit. The label is the only way that the item can be correctly identified and as such
needs to have, as a minimum, the following information:
1.
2.
3.
4.
Study number.
Replicate number.
Date.
Sample location.
3.5.4. Fortified and Blank Samples
For each day of the field study, there needs to be fortified and blank media samples
from the field. The volume selected for the fortification should be representative of the
residue expected on the media in the field study. However, the volume fortified needs
to be accurate, so very small volumes are usually avoided. The steps required for field
fortification are as follows:
1. Select an area of the field or building similar to that where other media samples for the
study are prepared. This needs to be free from contamination and should be an area upwind of the application area.
2. Samples of each media type (minimum three replicates for fortified samples and three
replicates for blank sample) should be laid out on polythene sheeting or aluminum foil in
an area not too distant (e.g., less than 500 m) from the area where the pesticide application is taking place.
3. Fortify (spike) the media samples with the sample of pesticide solution taken from the
nozzle of the application equipment. Suggested fortification volumes are as follows:
a. 0.1 mL for ground deposit media and coveralls.
b. 0.05 mL for the media used for the airborne pesticide sampling.
A gas chromatographic syringe can be used for the 0.05-mL volumes, and an Eppendorftype pipet can be used for the 0.1-mL volumes.
4. Leave all samples for a period equivalent to the duration of the field study to ensure that
the media are exposed to the same ambient conditions as the media used for the experimental samples from the field.
5. At the end of the exposure period, the samples are treated in the same manner as the field
samples, as detailed in Subheading 3.5.2.
3.5.5. Storage of Samples
Once all of the field samples together with field blanks and fortified samples have
been collected and labeled, they need to be stored together in a container to protect
them from extreme temperatures and sunlight. This is sufficient for most pesticides
(analytes). The analytical validation work done in the laboratory by the analytical service prior to commencing the fieldwork will indicate the stability of the analyte used
in the study. If the analyte is unstable in ambient conditions (e.g., 20°C), then samples
will need to be transported to the laboratory immediately or carried in transit in a cool
box with ice blocks. In extreme cases, dry ice (solid carbon dioxide) may be required
Bystander Exposure to Pesticides
175
for long-distance transport and care should be taken to avoid a buildup of carbon dioxide gas in vehicles during transport.
3.6. Expression of Data
3.6.1. Analytical Data
The media samples from the field can be analyzed by any competent analytical
laboratory. The analytical protocol needs to stipulate the nature of the data that will be
returned. It is normal for the raw data to be returned to express the mass of pesticide or
volume of tracer solution on each individual media sample. The raw data need to be
manipulated to allow the data to be presented in terms of potential bystander exposure.
The ground fallout data should be presented as the mass of pesticide or volume of
tracer per unit area or as a proportion of the pesticide or tracer applied to the crop (14).
3.6.2. Ground Fallout Data
The data for ground fallout should be presented as the mass of pesticide or volume
of tracer per unit area (e.g., square meter). These data can also be represented as a
proportion of the pesticide or tracer applied to a unit area of the crop (hectare or acre).
A typical example of a calculation for a pesticide study is as follows:
Area of ground sample media = 60 cm2
Mass of pesticide on sample media = 0.005 mg
Mass of pesticide per square meter = 0.833 mg/m2 (10,000 cm2 = 1 m2)
From the dose rate of the pesticide, the unit dose can be calculated. For example, a
product applied at 500 g per hectare would have, per square meter of crop area,
500/10,000 = 0.05 gm–2 (50 mg/m2)
In the example, the proportion of the applied dose drifting would be
(0.833/50) × 100 = 1.67%
Such values can be used as generic data to estimate exposure in similar field conditions with pesticides used at different dose rates. The current trend in Europe is to use
data for the drift deposition on a 2-m2 area of ground to be equivalent to the potential
dermal exposure of a bystander at the same distance from the application area (6).
3.6.3. Airborne Drift Data
For passive samples such as the polythene lines, these data can be presented as the
mass of pesticide or volume of tracer passing through a unit area. If 2-mm diameter
lines are used as suggested in Subheading 3.3.2., then the mass of pesticide can be
estimated for a surface area equivalent to a bystander. The default value for a bystander is often taken as 2 m2, so it could be assumed that half of this area would be
exposed to any airborne drift.
176
Glass
Again, this can be related to the output from the sprayer by calculating the output of
spray per meter traveled for a single pass. For example, if for every meter traveled by
the sprayer, 150 mL of liquid were applied to the crop, this is calculated as follows:
Forward speed of sprayer calculated as 2 m/s (0.5 s to travel 1 m)
Flow rate measured as 0.75 L/min for each of 24 nozzles (18 L/min)
Flow rate per 0.5 s (1 m) would be
18/120 = 0.15 L (150 mL)
If the volume of spray deposited on the lines was 10 mL for a frame 1-m wide, then
the proportion of spray passing through his frame would be
(10/150) × 100 = 0.67%
For active sampling using the personal air samplers, then the calculation is simpler.
The mass of pesticide sampled is related to the volume of air sampled. For example, if
15 mg of pesticide are found to be on the sampling device, and the volume of air
sampled was 10 L, then the concentration of pesticide in the air would be
15/10 = 1.5 µg/L
The concentration of the pesticide in the air can be related to inhalation exposure of
the bystander by using an appropriate breathing rate for an adult, such as 3.6 m3/h.
3.6.4. Mannequin or Volunteer Data
The mannequin or volunteer data are likely to be the most realistic because the
amount of pesticide or tracer deposited on the coverall of the mannequin or volunteer
is the value for the potential dermal exposure of the bystander. The data can be presented for regions of the body (e.g., the mass of pesticide found on the hood of the
coverall or on the arms). However, it is normal practice to use the value for the entire
body and express these data as the potential dermal bystander exposure. For most
studies, the duration of the study will be short, so relating the exposure to a period of
exposure is not appropriate. For inhalation exposure data, the study may last longer.
The data can be related to duration of exposure.
If a number of collection types have been used in the field, the data from these can
be compared. This will give an indication of the relative merits of each type of collection device.
Acknowledgments
I wish to acknowledge the financial support of the UK Department for Environment, Food, and Rural Affairs (DEFRA), formerly the Ministry of Agriculture, Fisheries, and Food (MAFF), which has allowed many of the methods described here to be
developed and validated. The financial support of the European Union SMT program
is also acknowledged, through project SMT4-CT96-2048.
Bystander Exposure to Pesticides
177
References
1. Gilbert, A. J. and Bell, G. J. (1988) Evaluation of the drift hazards arising from pesticide
spray application. Aspects Appl. Biol. 17, 363–367.
2. Mathers, J. J., Wild, S. A., and Glass, C. R. (2000) Comparison of ground deposit collection media in field drift studies. Aspects Appl. Biol. 57, 242–248.
3. May, K. R. and Clifford, R. (1967). The impaction of aerosols on cylinders, spheres, ribbons and discs. J. Occup. Hygiene 10, 83–95.
4. EPPO (2003) Environmental risk assessment scheme for plant protection products. EPPO
Bull., 33, 115–129.
5. Landers, A. (2000) Drift reduction in the vineyards of New York and Pennsylvania.
Aspects Appl. Biol. 57, 67–73.
6. Gilbert, A. EUROPOEM Bystander Working Group Report. (2002, December). Project
FAIR CT96-1406, European Commission, Brussels, Belgium.
7. Zande, J. C. van de, Porskamp, H. A. J., Michielsen, J. M. P. G., Holterman, H. J., and
Huijsmans, J. F. M. (2000) Classification of spray application for driftability to protect
surface water. Aspects Appl. Biol. 57, 57–65.
8. Birchfield, N. (2004) Pesticide spray drift and ecological risk assessment in the US EPA:
a comparison between current default spray drift deposition levels and AgDRIFT predictions in screening-level risk assessment. Aspects Appl. Biol. 71, 125–131.
9. Martínez Peck, R. (2004) Spraying techniques used in Argentina. Aspects Appl. Biol. 71,
475–480.
10. BSI. Equipment for Crop Protection. Methods for the Field Measurement of Spray Drift,
Draft British Standard (ISO/CD 12057), BSI, London.
11. Moreira, J. F., Santos, J., Glass, C. R., Wild, S. A., and Sykes, D. P. (2000) Measurement
of spray drift with hand held orchard spray applications. Aspects Appl Biol. 57, 399–404.
12. Capri, E., Alberci, R., Glass, C. R., Minuto, G., and Trevisan, M. (1999) Potential operator
exposure to procymidone in greenhouses. J. Agric. Food Chem. 47, 4443–4449.
13. Cross, J. V., Murray, R. A., Walklate, P. J., and Richardson, G. M. (2004) Pesticide Dose
Adjustment to the Crop Environment (PACE): efficacy evaluations in UK apple orchards
2002–2003. Aspects Appl. Biol. 71, 287–294.
14. Matthews, G. and Hamey, P. Y. (2003). Exposure of bystanders to pesticides. Pesticide
Outlook 14, 210–212.
Determination of Insecticides in Indoor Air
179
14
Determination of Household Insecticides in Indoor
Air by Gas Chromatography–Mass Spectrometry
Edith Berger-Preiss and Lutz Elflein
Summary
An analytical method for the determination of commonly used insecticides and
acaricides (pyrethroids, organophosphates, carbamates, organochlorine pesticides) in
indoor air is described. Air samples are collected with a sampling train consisting of a
glass fiber filter (GFF) and two polyurethane foam (PUF) plugs, followed by a highvolume air pump. This combination is used to sample particle-bound compounds (on the
GFF) as well as gaseous compounds (on the PUF plugs). GFFs and PUF plugs are
extracted separately with ethyl acetate as solvent in an ultrasonic bath subsequent to the
sampling. The extracted insecticides and acaricides are identified and quantified by gas
chromatography–mass spectrometry with electron impact ionization in the selected ion
monitoring mode (GC–MS/EI/SIM).
Key Words: Air sampling; analysis; carbamates; gas chromatography; mass spectrometry; glass fiber filter; organochlorine pesticides; organophosphorus compounds;
polyurethane foam; pyrethroids.
1. Introduction
A wide variety of biocidal products for indoor use is available on the market for
both consumers and professionals. These products contain active ingredients such as
pyrethroids, organophosphates, organochlorines, and carbamates. Some of these compounds may persist in the indoor environment over a long period of time. To assess
possible hazards to human health that may result from the indoor use of insecticides/
acaracides, multicomponent analytical methods to determine the active ingredients of
these biocides, especially in indoor air, are a prerequisite. Several methods for the
analysis of single components or compound classes have been reported previously for
different air-sampling techniques (using, e.g., Tenax®, Chromosorb®, XAD®, extraction disks, polyurethane foam, air containers, impingers, impactors, glass fiber filters
(GFFs) or activated carbon as sampling media) and analytical methods for analyte
determination (e.g., liquid chromatography with ultraviolet detection and gas chromaFrom: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
179
180
Berger-Preiss and Elflein
tography [GC] with electron capture, nitrogen–phosphorus-sensitive, or mass spectrometric [MS] detection) (1–19).
The method described in this chapter permits sensitive and simultaneous determination of active ingredients of biocide products such as carbamates, pyrethroids,
organophosphorus, and organochlorine compounds in indoor air down to the low nanogram-per-square-meter range (20). A high-volume pump and a sampling unit with a
GFF and two polyurethane foam (PUF) plugs are used for air sampling, allowing the
collection of large volumes of air and separate determination of particle-bound and
gaseous compounds. Gas chromatography–mass spectrometry with electron impact
ionization and in selected ion monitoring (GC–MS/EI/SIM) mode is applied to provide high sensitivity and selectivity in multicomponent analysis.
2. Materials
2.1. Equipment
2.1.1. Air-Sampling Equipment
1. Air-sampling unit (see Fig. 1) consisting of a stainless steel cylinder carrying two PUF
plugs, a filter holder carrying a GFF, and a tube adapter.
2. GFF GF 10, 50-mm diameter.
3. PUF plugs, 60-mm diameter × 50 mm (see Note 1).
4. High-volume pump (flow rate ⱖ 0.05 m3/h).
5. Gas meter for sample volume determination.
6. Flow meter with restrictor for flow rate adjustment.
7. Timer.
8. Thermometer.
9. Hygrometer.
10. Barometer.
11. A pair of tweezers (filter handling).
12. Crucible tongs (PUF handling).
13. Petri dishes with caps for storage of filter samples.
14. 250-mL Amber bottles with a wide opening and screw tops for storage of PUF plugs.
15. Aluminum foil.
2.1.2. Equipment for Extraction
1. Ultrasonic bath for extraction.
2. Glass ware: beakers (50, 300, 600 mL), bulb flasks (250 mL), bulb or tubular flasks with
graduated stem (50 mL, graduation 0–5 mL), Pasteur pipets, volumetric flasks (1, 10, and
100 mL), and GC vials (2 mL) with inserts.
3. Plastic (polypropylene) microliter pipet tips plugged with silanized glass wool.
2.1.3. Analytical Equipment
1. Gas chromatograph (e.g., Agilent 6890, Palo Alto, CA) with split/splitless injector and an
autosampler (e.g., Agilent 7683).
2. Mass selective detector (MSD; e.g., Agilent 5973N).
3. Software for data acquisition and data analysis (e.g., HP Chemstation, Avondale, PA), including a mass spectral database (e.g., National Institute of Standards and Technology [NIST]).
4. GC capillary column 60 m long, 250 µm id, 0.25 µm df; bonded phase of 5% diphenyl
and 95% dimethylpolysiloxane on fused silica (e.g., Agilent HP-5 MS).
Determination of Insecticides in Indoor Air
181
Fig. 1. Air-sampling unit for the collection of particle-bound and gaseous compounds in
indoor air (top: assembled; bottom: disassembled). The parts from right to left are air plate, air
streamer, rubber sealing, Teflon O-ring, GFF, wire mesh support, Teflon O-ring, cylinder, PUF
plugs, rubber sealing, tube adapter.
2.2. Chemicals
1. Ethyl acetate (pesticide grade).
2. Standard substances: allethrin, chlorodecone, chlorpyrifos, cyfluthrin, cyhalothrin,
cypermethrin, deltamethrin, diazinon, dichlorvos, fenitrothion, fenthion, fenvalerate, lindane, malathion, permethrin, phenothrin, piperonyl butoxide, propoxur, resmethrin,
tetramethrin.
2.3. Calibration Solutions (see Note 2)
2.3.1. Preparation of Standard Solutions
1. Weigh approx 20 mg of each standard substance into separate 10-mL volumetric flasks.
Dissolve in 5–8 mL ethyl acetate. If necessary, utilize ultrasonic irradiation to facilitate
dissolution. Fill up to the index mark with ethyl acetate (individual standard solutions,
concentration 2000 µg/mL each).
2. Transfer 0.5 mL of each individual standard solution to a 100-mL volumetric flask and fill
up to the index mark with ethyl acetate (standard mix solution, concentration 10 µg/mL).
2.3.2. Preparation of Matrix-Matched Calibration Solutions
1. Prepare extracts of GFF and PUF plugs after sampling pesticide-free air according to
Subheadings 3.1. and 3.2. (extracts of five samples). Collect the individual extracts of
the GFF and PUF plugs in separate vessels.
2. Prepare matrix-matched calibration solutions of 0.1, 0.5, 1.0, 1.5, and 2.0 µg/mL by
pipeting 10, 50, 100, 150, or 200 µL of the standard mix solution (10 µg/mL) into a 1-mL
volumetric flask and by filling up to the index mark with the extracts obtained according
to step 1. Prepare matrix-matched calibration solutions for GFF and PUF matrix calibration separately.
182
Berger-Preiss and Elflein
3. Methods
The method outlines (1) the sampling of selected active ingredients of biocidal
products in air (i.e., the pyrethroids allethrin, cyfluthrin, cyhalothrin, cypermethrin,
deltamethrin, fenvalerate, permethrin, phenothrin, resmethrin, and tetramethrin; the
organophosphates chlorpyrifos, dichlorvos, diazinon, fenitrothion, fenthion, and
malathion; diflubenzuron [benzoyl-phenyl urea]; propoxur [carbamate]; the chlorinated pesticides chlorodecone and lindane; and insecticide synergist piperonyl butoxide; (2) the extraction methods used for GFFs and polyurethane foams; and (3) the
analytical determination by GC–MS.
3.1. Air Sampling
1. Insert the two PUF plugs into the cylinder of the air-sampling unit (Fig. 1) using clean
crucible tongs. Screw the tube adapter with the rubber sealing onto the cylinder to close
this side of the cylinder.
2. Place the GFF together with the Teflon O-rings and the wire mesh support into the filter
holder on the other side of the cylinder (according to the order shown in Fig. 1) using a
clean pair of tweezers. Screw the air plate and steamer with the rubber sealing onto the
cylinder.
3. Install the sampling unit about 1–1.5 m above the floor and at least 1 m away from the
walls. Connect the sampling unit, flow meter, gas meter, and pump in a series. Record
time, temperature, relative humidity, and air pressure. Start the pump and collect a total
sample volume of about 10 m3 air (flow rate of about 0.05 m3/min).
4. Stop the pump, record the time and sample volume, and remove the filter and PUF plugs
from the air-sampling unit; transfer the filter into a petri dish protected with aluminum
foil (see Note 3) and the PUF plugs into a wide-opening amber bottle (use a clean pair of
tweezers and clean crucible tongs, respectively, to avoid contamination).
3.2. Sample Preparation (see Note 4)
3.2.1. Glass Fiber Filter
1. Cut the GFF (containing the particle fraction of the sample) with a clean pair of scissors
and transfer it into a 50-mL glass beaker.
2. Add approx 10 mL of ethyl acetate.
3. Place the glass beaker into an ultrasonic bath and extract the filter for 5 min.
4. Transfer the extract into a bulb or tube flask with graduated stem and repeat this ultrasonic extraction procedure two more times.
5. Reduce the combined extracts to about 0.5 mL with a gentle flow of nitrogen (see Note 5).
6. Take up the reduced extract solution with a Pasteur pipet and filtrate through a 1-mL microliter pipet tip plugged with silanized glass wool into a 1-mL volumetric flask. Rinse the flask
with approx 0.4 mL ethyl acetate and wash the pipet tip used for filtration with the solvent.
7. Adjust the final volume in the volumetric flask to 1 mL with ethyl acetate.
3.2.2. PUF Plugs
1. Place each PUF plug (containing the gaseous fractions of the sample) separately into a
600-mL glass beaker.
2. Add approx 50 mL ethyl acetate onto the top of the plug.
3. Put the glass beaker into an ultrasonic bath and squeeze the PUF plug periodically with
the bottom of a 300-mL glass beaker during a 2-min extraction time.
Determination of Insecticides in Indoor Air
183
4. Squeeze the plug between the two beakers and pour the extract into a bulb flask. Repeat
this extraction procedure three more times.
5. Reduce the combined extracts to 2–3 mL using a rotary vacuum evaporator. Transfer the
extract with a Pasteur pipet into a bulb or tube flask with graduated stem. Rinse the bulb
flask two times with approx 1 mL ethyl acetate and transfer the rinses into the graduated
flask. Reduce the combined solutions to a volume of about 0.5 mL with a gentle flow of
nitrogen (see Note 5).
6. Take up the reduced extract solution with a Pasteur pipet and filtrate through a 1-mL
microliter pipet tip plugged with silanized glass wool into a 1-mL volumetric flask. Rinse
the flask with approx 0.4 mL ethyl acetate and wash the pipet tip used for filtration with
the solvent.
7. Adjust the final volume in the volumetric flask with ethyl acetate to 1 mL.
3.3. Analytical Determination
3.3.1. Measurement Parameters
1. Column: see Subheading 2.1.3.; carrier gas is helium 1.4 mL/min (constant-flow mode).
2. GC temperatures are as follows: 250°C injection port; oven program 60°C (1 min), 60–
170°C (10°C/min), 170–280°C (4°C/min), 280°C (25 min); 280°C transfer line.
3. MSD: positive EI ionization mode, 70-eV ion potential, 230°C ion source, 150°C quadrupole.
4. Data acquisition: Select the SCAN mode for compound identification. Use SIM mode for
quantification; select two ions per analyte.
Target and qualifier ions (m/z): allethrin (123/79), chlorodecone (272/237), chlorpyrifos
(197/314), cyfluthrin (163/215), cyhalothrin (181/141), cypermethrin (163/127),
deltamethrin (181/93), diazinon (179/137), dichlorvos (109/185), fenitrothion (277/125),
fenthion (278/125), fenvalerate (167/125), lindane (181/219), malathion (173/125),
permethrin (183/127), phenothrin (123/183), piperonyl butoxide (176/119), propoxur
(110/152), resmethrin (123/171), tetramethrin (164/123) (see Notes 6–8).
3.3.2. Matrix-Matched Calibration and Sample Measurement
3.3.2.1. GFF SAMPLES
1. Use the SCAN mode of the MSD and inject 1 µL of a calibration sample (2 µg/mL) into
the GC system.
2. Identify each compound by comparison of the measured mass spectra with the search
results of the mass spectral database.
3. Use the SIM mode (target and qualifier ions [m/z]; see Subheading 3.3.1.) and subsequently inject (splitless) 1 µL of each matrix-matched calibration solution. Measure each
level twice (see Note 9).
4. Plot the concentration of each compound of the calibration solution as a function of the
peak areas (obtained after peak integration) and calculate the regression function of the
calibration curve for each compound (see Note 10). Examples of calibration curves for
chlorpyrifos and permethrin are shown in Fig. 2.
5. Inject 1 µL (splitless) of a GFF sample extract (see Subheading 3.2.1.) and determine the
peak area after peak integration. A chromatogram of a filter sample extract is shown in
Fig. 3.
3.3.2.2. PUF PLUG SAMPLES
1. Apply the same procedure as described for the GFF samples, but now use the matrixmatched PUF calibration solutions (see Note 9).
184
Berger-Preiss and Elflein
Fig. 2. Calibration curves (y-axis: counts; x-axis: concentration in micrograms per milliliter) of chlorpyriphos and permethrin (GFF matrix).
2. Inject 1 µL (splitless) of a PUF sample extract (see Subheading 3.2.2.) and determine the
peak area after peak integration. Sample chromatograms are shown in Figs. 4 and 5.
3.3.3. Analyte Identification and Quantification
1. Identify each compound by its retention time and target/qualifier ion response ratio. Differences in retention times should not exceed those of the calibration solutions by more
than 0.5% (usually about 0.1%). Differences in the ion peak ratios used for analyte identification should not exceed those determined for the calibration solutions by more than 20%.
2. Determine the total amount of each analyte detected in the sample solution using the
corresponding calibration function. If necessary, take dilution factors into account (see
Note 11).
3. Calculate the amount of analyte in the air as follows:
Cair = (Csample × Vsample × d)Vair
where Cair is the concentration of the active ingredient in the air (µg/m3), Csample is the
concentration of the active ingredient in the sample extract (µg/mL), Vsample is the volume
of the sample extract (mL; 1 mL in the described method), d is the dilution factor, and Vair
is the air volume (m3).
3.3.4. Quality Assurance
1. Prepare blank samples (extract GFFs and PUF plugs; see Subheadings 3.2.1. and 3.2.2.)
and analyze them in SIM mode to check for blank values).
2. Check calibration by injecting a 1-µg/mL matrix-matched standard solution after every
10 samples (GFFs) and after every 5 samples (PUF plugs) (see Note 12).
3. Determine recoveries: Pipet 100 µL of the standard mix solution (concentration 10 µg/
mL) onto the center of the GFF and into the PUF plugs (1 µg absolute), extract the filter
(see Subheading 3.2.1.) and PUF plugs (see Subheading 3.2.2.), and analyze the extracts as described in Subheading 3.3.3. (see Note 13). Use a minimum of three GFFs
and PUF plugs for recovery studies (see Note 14).
4. Notes
1. The PUF plugs (30-kg/m3 density) are made by polymerization of toluene diisocyanate
and polyoxypropylenetriol. For initial cleanup before use, extract the foam plugs in a 1-L
Soxhlet apparatus (approx 30 extraction cycles each) successively with toluene (16 h),
Determination of Insecticides in Indoor Air
185
185
Fig. 3. Total ion current (TIC) chromatogram (y-axis: counts; x-axis: retention time in minutes; SIM mode) of the filter extract after an indoor
spraying experiment: (1a) p-chlorobenzene-isocyanate; (1b) 2,6-difluorobenzene amide; (2) dichlorvos; (3) propoxur; (4) lindane; (5) diazinon;
(6) fenitrothion; (7) malathion; (8) fenthion; (9) chlorpyrifos; (10) allethrin; (11) chlorodecone; (12) piperonyl butoxide; (13) resmethrin; (14)
tetramethrin; (15) phenothrin; (16) cyhalothrin; (17) permethrin (two peak isomers); (18) cyfluthrin (four peak isomers); (19) cypermethrin
(four peak isomers); (20) fenvalerate (two peak isomers); (21) deltamethrin.
186
186
Berger-Preiss and Elflein
Fig. 4. TIC chromatogram (y-axis: counts; x-axis: retention time in minutes; SIM mode) of the extract of the first PUF plug after an indoor
spraying experiment (peak assignment, see Fig. 3).
Determination of Insecticides in Indoor Air
187
187
Fig. 5. TIC chromatogram (y-axis: counts; x-axis: retention time in minutes; SIM mode) of the extract of the second PUF plug after an indoor
spraying experiment (peak assignment, see Fig. 3).
188
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
Berger-Preiss and Elflein
acetone (16 h), and ethyl acetate (16 h). After extraction, remove the bulk of the solvent
by squeezing the plugs between the bottoms of two 600-mL glass beakers. Dry the plugs
in an exsiccator using a small flow of nitrogen. Store the foams in 250-mL wide-opening
amber bottles until use.
Standard solutions are stable at 4–7°C for more than 1 yr; matrix-matched calibration
solutions must be prepared fresh because fenthion degrades in the presence of matrix.
Matrix-matched calibration is necessary to obtain accurate results in sample measurements (matrix-induced signal enhancement) as described in detail in ref. 20.
Be careful during transport to avoid sample loss because of contact of the exposed side of
the filter with the glass walls of the petri dish. Fold the exposed filter (exposed side against
exposed side) and place into the petri dish.
Extract the filter and PUF plugs as soon as possible to avoid analyte loss caused by degradation or evaporation.
Use a Pasteur pipet, for instance, to blow nitrogen into the flask. The flask may be placed
into a water bath (20–30°C) to facilitate solvent evaporation. Alternatively, a commercial
sample concentration workstation with nitrogen-assisted solvent evaporation and sample
heating block can be used.
Under the given conditions, diflubenzuron decomposes completely in the injection port,
resulting in two thermal degradation products (i.e., para-chlorobenzene isocyanate and
2,6-difluorobenzene amide), which are monitored. Use 2,6-difluorobenzene amide (141/
157) for quantification of diflubenzuron.
Use the underlined ion (m/z) for quantification (target ion) and the second ion (m/z) for
the confirmation of a specific compound (qualifier ion). Identify every compound by
retention time and target/qualifier ion response ratio.
Usually, the two most intense ion signals of each compound observed in the SCAN mode
are chosen. The more characteristic ion, which usually is the one with the higher mass or
the highest abundance, is used as target ion, the other one as qualifier ion. However for
some compounds (piperonyl butoxide, cyfluthrin, deltamethrin), different ions are selected because of interferences with signals from ubiquitously present phthalates (m/z
149) and GC column bleeding substances (m/z 207, 253).
Inject matrix samples (five times) before starting a calibration procedure. This procedure
allows the equilibration of the analytical system (injection port liner, column).
It was observed that quadratic regression functions are often better suited, especially for
pyrethroids and organophosphorus compounds.
If the sample signal exceeds the range of the calibration curve, dilute the sample and note
the dilution factor for calculations. Repeat the analysis once.
Recalibrate if deviation is 20% or more (GFF) or 25% or more (PUF).
Extract the GFFs immediately after evaporation of ethyl acetate. Otherwise, allethrin,
phenothrin, resmethrin, and tetramethrin cannot be recovered quantitatively.
The recovery rates of the analytes for spiked filters (without air throughput) range from
87 to 118%, relative standard deviation (RSD) 3–10% (except 40% recovery for dichlorvos). The recovery rates for PUF plugs (without air throughput) are between 89 and 107%,
RSD 5–9% (except 65% recovery for dichlorvos). The minimum method detection limits
for most active ingredients in the air are 0.1–0.3 ng/m3 (except 1 ng/m3 for fenvalerate
and 4–5 ng/m3 for cyfluthrin, cypermethrin, and deltamethrin). The method validation is
described in detail in ref. 20.
Determination of Insecticides in Indoor Air
189
Acknowledgment
The financial support of the Federal Institute for Risk Assessment (BfR), formerly
the Federal Institute for Health Protection of Consumers and Veterinary Medicine
(BgVV) in Berlin, is gratefully acknowledged.
References
1. Class, T. J. (1991) Determination of pyrethroids and their degradation products in indoor
air and on surfaces by HRGC–ECD and HRGC–MS(NCI). J. High Res. Chromatogr. 14,
446–450.
2. Leidy, R. B. and Wright, C. G. (1991) Trapping efficiency of selected adsorbents for various airborne pesticides. J. Environ. Sci. Health 26, 367–382.
3. Roinestad, K. S., Louis, J. B., and Rosen, J. D. (1993) Determination of pesticides in
indoor air and dust. J. AOAC Int. 76, 1121–1126.
4. Schenk, G., Rothweiler, H., and Schlatter, C. (1997) Human exposure to airborne pesticides in homes treated with wood preservatives. Indoor Air 7, 135–142.
5. Riegner, K. and Schmitz, J. R. (1994) Production of a test atmosphere and separation of
gaseous and particle-bound crop-protection agent residues from air in Tenax sampling
tubes. Planzenschutz-Nachrichten Bayer 47, 157–171.
6. Matoba, Y., Takimoto, Y., and Kato, T. (1998) Indoor behavior and risk assessment following space spraying of d-tetramethrin and d-resmethrin. AIHA J. 59, 181–199.
7. Clément, M., Arzel, S., Le Bot, B., Seux, R., and Millet, M. (2000) Adsorption/thermal desorption–GC/MS for the analysis of pesticides in the atmosphere. Chemosphere 40, 49–56.
8. Haraguchi, K., Kitamura, E., Yamashita, T., and Kido, A. (1994) Simultaneous determination of trace pesticides in urban air. Atmospheric Environ. 28, 1319–1325.
9. Millet, M., Wortham, H., Sanusi, A., and Mirabel, P. (1996) A multiresidue method for
determination of trace levels of pesticides in air and water. Arch. Environ. Contam.
Toxicol. 31, 542–556.
10. Murayama, H., Mukai, H., Mitobe, H., and Moriyama, N. (2000) Simple method for determining trace pesticides in air using extraction disks. Anal. Sci. 16, 257–263.
11. Berger-Preiss, E., Preiss, A., Sielaff, K., Raabe, M., Ilgen, B., and Levsen, K. (1997) The
behaviour of pyrethroids indoors. Indoor Air 7, 248–261.
12. Turner, B. C. and Glotfelty, D. E. (1977) Field air sampling of pesticide vapors with polyurethane foam. Anal. Chem. 49, 7–10.
13. Hsu, J. P., Wheeler, H. G., Jr., Camann, D. E., and Schattenberg, H. J. J. (1988) Analytical
methods for detection of nonoccupational exposure to pesticides. Chromatogr. Sci. 26,
181–189.
14. Foreman, W. T., Majewski, M. S., Goolsby, D. A., Wiebe, F. W., and Coupe, R. H. (2000)
Pesticides in the atmosphere of the Mississippi River Valley, part II—air. Sci. Total
Environ. 248, 213–216.
15. Majewski, M. S., Foreman, W. T., Goolsby, D. A., and Nakagaki, N. (1998) Airborne
pesticide residues along the Mississippi River. Environ. Sci. Technol. 32, 3689–3698.
16. Ramesh, A. and Vijayalakshmi, A. (2001) Monitoring of allethrin, deltamethrin,
esbiothrin, prallethrin and transfluthrin in air during the use of household mosquito repellents. J. Environ. Monit. 3, 191–193
17. Van Dyk, L. P. and Visweswariah, K. (1975) Pesticides in air: sampling methods. Residue
Rev. 55, 91–134.
190
Berger-Preiss and Elflein
18. Kawata, K., Mukai, H., and Yasuhara, A. (1995) Monitoring of pesticides in air by gas
chromatography–mass spectrometry and the use of quartz–fibre wool and activated carbon for sampling. J. Chromatogr. A 710, 243–250.
19. Kawata, K. and Yasuhara, A. (1994) Determination of fenitrothion and fenthion in air.
Bull. Environ. Contam. Toxicol. 52, 419–424.
20. Elflein, L., Berger-Preiß, E., Levsen, K., and Wünsch, G. (2003) Development of a gas
chromatography–mass spectrometry method for the determination of household insecticides in indoor air. J. Chromatogr. A 985, 147–157.
Exposure to Malathion and Metabolites
191
15
Assessment of Dermal and Inhalatory Exposure
of Agricultural Workers to Malathion Using Gas
Chromatography–Tandem Mass Spectrometry
Francisco J. Egea González, Francisco J. Arrebola Liébanas,
and A. Marín
Summary
The exposure of agricultural workers to malathion is assessed from different
approaches. Methods for potential and actual exposure assessment are proposed and validated using gas chromatography with tandem mass spectrometry (GC–MS/MS) as the
analytical technique. The metabolites α- and β-malathion monocarboxylic acids (α- and
β-MMA) are determined after a derivatization process to obtain their hexafluoroisopropyl
esters. Whole-body dosimetry is used for potential dermal exposure assessment. Inhalation exposure is estimated with active air sampling using personal air samplers and polyurethane foam (PUF) plugs as sorbents. The internal dose measurements are carried out
by analyzing urine samples, which are extracted by applying solid-phase extraction (SPE)
with C18. The recoveries of the analytes of the three matrices are between 90 and 102%.
Quantification limits are lower than 0.24 ng/L. The proposed methods are applied to
assess potential and actual exposure of applicators spraying malathion in greenhouses.
Key Words: Biomonitoring; dermal exposure; GC–MS/MS inhalation exposure;
malathion; metabolites.
1. Introduction
Directive 91/414/EEC (1) is the legislative basis for the regulation of pesticides in
the European Union. It states that members shall not allow a pesticide to be authorized
unless it is scientifically shown that normal use has no risk of harmful effects on humans, establishing exposure data requirements. The approaches for assessing dermal
exposure have been well described in several reviews (2–4) in which patch and wholebody dosimetry are discussed as sampling methods. It was concluded that there is a
need for systematic research on sampling and analytical methods to choose the adequate sampling media and to establish performance parameters for analytical proceFrom: Methods in Biotechnology, Vol. 19 Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
191
192
Egea González, Arrebola Liébanas, and Marín
dures. One advantage of whole-body dosimetry is its compatibility with biological
monitoring. The analysis of the coverall worn by applicators to obtain potential dermal exposure and the use of biological monitoring to measure the internal dose appear
the most sophisticated tools in exposure assessment.
The Organisation for Economic Cooperation and Development (OECD) (5) reports
a guidance for the study of potential dermal occupational exposure, including a quality
assurance and quality control procedure mainly to the sampling step. Nevertheless,
from a practice point of view aspects that might affect the reliability of results should
also be considered, such as the matrix effect in the quantification of pesticides or the
influence of the retention characteristics of different clothes used for whole-body dosimetry, because they may affect the exposure assessment (6,7). Relative to ambient
air monitoring, most references address the active sampling using solid sorbents attached to personal pumped air samplers as the best methodology for determining pesticides in air. In this aspect, it is important to consider both the generation of pesticide
standard vapors for validation purposes and the range of air concentrations in which
the sorbent is suitable without saturation or breakthrough (8,9).
Malathion, diethyl(dimethoxythiophosphorylthio) succinate, is a very widely used
nonsystemic insecticide and acaricide with contact, stomach, and respiratory action. It
is a cholinesterase inhibitor of low mammalian toxicity. Many studies have assessed
the metabolic effects of malathion on insects (10), rats, and humans (11). The principal route of malathion metabolism in animals is via deesterification to the α- and βmalathion monocarboxylic acids (α- and β-MMA), followed by further metabolism to
malathion dicarboxylic acid (MDA). This is a facile esterase-catalyzed detoxification
route considered responsible for the low toxicity of malathion to vertebrates. Another
metabolic pathway is the oxidative desulfuration that leads to the formation of
malaoxon, an active acetylcholinesterase inhibitor.
The main metabolites detected in humans are α- and β-MMA. Appreciable amounts
of MDA are also found, but malaoxon is a minor metabolite. Additional human metabolites identified were O,O-dimethyl phosphorodithioate, O,O-dimethyl
phosphorothioate, dimethyl phosphate, and monomethyl phosphate. Malathion is metabolized and then excreted predominantly in the urine (85–89%) and feces (4–15%).
Therefore, the best way to determine the actual exposure to malathion is by analyzing
MMA and MDA in urine. The analysis of MDA presents difficulty in that it is not
easily obtained in the pure state for use as an analytical standard. In addition, it is not
very stable. Unlike MDA, MMA is stable in the pure state and can be commercially
obtained.
Gas chromatography with tandem mass spectrometry (GC–MS/MS) has been successfully applied for determining other metabolites and pesticides in biological monitoring (12–15). The combination of the above-mentioned techniques allows the
analysis of ultratrace levels of target compounds in complex matrices such as biological fluids (urine or blood). Also, the confirmation of the results carried out by MS/MS
spectra obtained in special experimental conditions reduces the possibility of false
positives compared with other MS techniques (selected ion monitoring or full-scan
modes) used as GC detectors.
Exposure to Malathion and Metabolites
193
It is evident that the likely consequences of exposure assessment data on human
health and economics justify the need to use several approaches and powerful analytical tools. As presented in this chapter, the most complete information can be obtained
by combining potential dermal, inhalation, and internal dose measurements supported
in GC–MS/MS detection. Analytical methods for analyzing malathion in different
types of sampling media, protective clothing, polyurethane foam (PUF), and urine (in
which metabolites α- and β-MMA are also determined) have been validated, establishing the respective performance parameters and the quality control procedure. Finally,
the exposure levels obtained for three pesticide applicators have been determined.
2. Materials
1. Pesticide-quality solvents: n-hexane, methanol, diethyl ether, and acetone.
2. Standards of the pesticides malathion, MMA, and chlorpyrifos-methyl used as internal
standard (ISTDs) with purity higher than 99%.
3. Formulation of malathion 90 (malathion 90% w/v, EL, Lainco, SA).
4. Anhydrous sodium sulfate.
5. Potassium carbonate.
6. 1,1,1,3,3,3-Hexafluoroisopropanol (HFIP).
7. Diisopropylcarbodiimide (DIC).
8. Sep-Pak cartridge packed with 500 mg C18 (e.g., Waters, Milford, MA).
9. Latex gloves.
10. 65% cotton, 35% polyester disposable coveralls (Iturri, Sevilla, Spain).
11. Protective mask (3M model 4251).
12. SKC personal air samplers model PCEX3KB working at a sampling flow rate of 2 L/min.
13. PUF plugs 10 cm long, 2-cm diameter, and 0.022 g/cm3 density.
14. Gas chromatograph (e.g., Varian 3800, Sunnyvale, CA) with a split/splitless programmed
temperature injector (e.g., Varian model 1078) and an autosampler (e.g., Varian model 8200).
15. Ion trap mass spectrometer (e.g., Varian Saturn 2000).
16. Software for data acquisition and data analysis (e.g., Varian Saturn 2000).
17. GC column DB5-MS 30 m × 0.25 mm id × 0.25-µm film thickness (e.g., J&W Scientific,
Folsom, CA).
18. Test tube shaker with a variable-speed controller (e.g., Ika-Works).
19. Overhead mixer (agitator) to hold containers (1-L capacity with lid) is used for cold extraction of contaminated clothes.
20. Soxhlet extractor used for the extraction of PUF plugs.
3. Methods
3.1. Sampling Procedure
Gloves and coveralls are the sampling media for the whole-body methodology.
After applications, remove them carefully and dry in the shade (see Note 1).
Inhalation exposure during the applications is assessed for each operator with a
personal sampler, operating at a 2-L/min flow rate (see Note 2), connected to a PUF
plug, which is fitted downward, on the upper part of the chest, avoiding accidental
contamination by dripping or contact with contaminated items. Replace the PUF plug
each hour to avoid saturation and breakthrough. Store plugs in labeled bags and in a
portable fridge.
194
Egea González, Arrebola Liébanas, and Marín
Because usually the pharmacokinetics of compounds are unknown for human beings, for biomonitoring we recommend taking between 7 and 10 urine samples from
each volunteer up to 24 h after the application of malathion (see Note 3). Urine samples
are stored in sterilized polyethylene containers, frozen immediately, and kept at −
30°C until analysis.
A field quality control protocol (see Note 4) must be followed to ensure the integrity of samples and analytes during sampling, transport, storage, and analysis. Take an
aliquot of the spray liquid from the gun 15 min after starting and at the end of each
application to check its concentration and perform field spikes. Uncontaminated
samples of each medium (coverall, cotton gloves, PUF, and urine) are taken from each
operator before the applications to prepare field blanks and field spikes as field quality
control samples. Three samples are labeled field blanks and stored in the same way as
samples to check accidental contamination or degradation of sampling media. The rest
of the blank samples are spiked as follows: Three cotton gloves and three pieces (30 ×
30 cm2) of protective coverall are spiked with 100 µL of the spray tank liquid (around
135 µg of malathion, depending on the spray tank concentration); three PUF plugs are
spiked with 5 µL of the spray tank liquid (6.8 µg of malathion); and three aliquots of
uncontaminated urine are also spiked with malathion and MMA standards at 40-µg/L
concentration level. Field blanks, field spikes, and samples have to be stored, processed, and analyzed in the same batch. According to the acceptance criteria assumed
(5), recovery rates of field spikes should be between 70 and 120%, with a relative
standard deviation (RSD) of less than 20%; field blanks should not evidence any contamination or sample decomposition; slopes of calibration curves should not differ
more than 25% from those obtained in validation studies and should fit to straight
lines with r2 > 0.95.
3.2. Preparation of Stock Solutions
Prepare individual stock solutions of malathion and methyl-chlorpyrifos at 400 µg/
mL in acetone and store in a freezer (−30°C). The working solutions for biological
monitoring determinations, obtained by appropriate dilution of the stock solution with
the same solvent, should be stored in a refrigerator (4°C). Matrix-matched calibration
solutions of malathion are prepared for whole-body analysis using acetone extracts
from uncontaminated coveralls.
3.3. Extraction Procedures
3.3.1. Urine Extraction Procedure
1. Condition a C18 solid-phase extraction cartridge with 6 mL of methanol and 4 mL of
distilled water in that order (see Note 5).
2. Pass a 3-mL aliquot of urine through the C18 cartridge previously conditioned.
3. To carry out a cleanup step, pass 4 mL of distilled water through the cartridge. The last
drops of liquid from the cartridge are withdrawn with a vacuum pump.
4. Elute the analytes with 10 mL diethyl ether, which is passed through anhydrous sodium
sulfate.
5. Add to the extract 100 µL of ISTD solution (500 ng/mL in acetone).
6. Remove the solvent under a soft stream of nitrogen without heating it.
Exposure to Malathion and Metabolites
195
7. Redissolve the residue in 1 mL n-hexane.
8. Derivatize, for metabolites analysis (14,16) (see Note 6), by adding to the extract 10 µL
HFIP with gentle mixing while adding 15 µL DIC.
9. Shake for 3 min.
10. Wash the extract with 1 mL 5% aqueous potassium carbonate solution to neutralize the
excess derivatizing agent.
11. Transfer the organic layer to a 2-mL autosampler vial for GC–MS/MS analysis.
3.3.2. Personal Protective Equipment Extraction Procedure
The extraction procedure is similar to that described in ref. 6 based on the sectioning of coveralls in nine pieces and further extraction with different volumes of acetone.
1. Cut coverall in pieces as in Fig. 1, place each piece separately in 1-L bottles, and add the
corresponding volume of acetone.
a. Head and neck (250 mL).
b. Left arm (250 mL).
c. Right arm (250 mL).
d. Chest (350 mL).
e. Back (350 mL).
f. Thighs/waist, front (350 mL).
g. Thighs/waist, back (350 mL).
h. Lower leg, left (250 mL).
i. Lower leg, right (250 mL).
j. Glove, left (150 mL).
k. Glove, right (150 mL).
2. Agitate for 30 min in an overhead shaker at 18g.
3. Transfer an aliquot of this extract to a 10-mL volumetric flask containing 3.5 µg of ISTD
to get ready for GC–MS/MS analysis (see Note 7).
3.3.3. PUF Plugs Extraction
1. Place PUF plugs in a Soxhlet extractor, siphoning at 20 min/cycle, with 100 mL of acetone
for 8 h.
2. Evaporate the extract until almost dry, add ISTD (0.4 µg), and dilute the extract to 4 mL
to get ready for GC–MS/MS analysis.
3.4. Instrumental Analysis
3.4.1. Chromatographic Conditions
1. Set the injector temperature from 90°C (hold 0.1 min at 90°C) to 280°C at the rate of
200°C/min and hold it at 280°C for 20 min.
2. Set the oven temperature varying from 60°C (hold for 1.75 min) to 270°C at the rate of
20°C/min (hold for 20 min).
3. Set the carrier gas (helium) flow rate at 1 mL/min.
3.4.2. Ion Trap Conditions
1. Set the ion trap mass spectrometer in the electron ionization (EI; 70 eV) and MS/MS modes.
2. Perform an MS/MS/EI library especially for the target analytes under the experimental conditions (see Note 8). This acts as a reference spectra library for identification
purposes.
196
Egea González, Arrebola Liébanas, and Marín
Fig. 1. Coverall sectioning.
3. Optimize the sensitivity for mass detection by filling the trap with target ions, switching
on the automatic gain control (AGC) (see Note 9). For example, fix the AGC target at
2000 counts (higher values might cause electrostatic interactions among ions in the ion
trap chamber).
4. Choose for analysis a parent ion for each analyte on the basis of its m/z and its relative
abundance; both should be as high as possible to achieve greater sensitivity. In this case,
a nonresonant waveform (second ionization) is selected for all the compounds.
5. Select the excitation storage level and excitation amplitude as appropriate to generate
spectra with the parent ion as their molecular peaks (between 10 and 20% of relative
abundance).
6. Calibrate the mass spectrometer weekly.
7. For the case study, the operating conditions are summarized in Tables 1 and 2. MS/MS is
performed in a nonresonant mode for all compounds. The MS/MS spectra obtained in the
selected experimental conditions are shown in Fig. 2 (see Note 10).
3.5. Validation of the Analytical Methods
3.5.1. Potential Dermal Exposure Method
1. Prepare calibration curves in a wide concentration range (500 and 1500 µg/L) with pure
standards and using blank extracts of uncontaminated coveralls to avoid matrix effects in
the quantification. For that, cut a 30 × 30 cm2 piece of coverall and extract it with 250 mL
acetone following the method explained above. Use such extract for filling up to the
volume of calibration solutions. The statistical data we obtained are summarized in Table
3 (see Note 11).
2. Calculate limits of detection (LODs) and limits of quantification (LOQs) by analyzing 10
uncontaminated pieces of coveralls and following the IUPAC recommendations (17). The
values obtained (Table 3) are in the ng/L level, a good indication of the sensitivity of MS/
MS (see Note 12).
Exposure to Malathion and Metabolites
197
Table 1
Mass Spectrometer Operating Conditions
Ionization mode
Multiplier voltage
A/M amplitude voltage
Trap temperature
Manifold temperature
Transfer-line temperature
Emission current
Automatic gain control (AGC)
AGC target
EI
1700 V
4.0 V
200°C
45°C
280°C
80 mA
On
2000 counts
Table 2
MS/MS Conditionsa
Compound
Activation
time (min)
Range
(m/z)
Parent ion
(m/z)
Mass
defect
(mu/100 u)
Excitation
amplitude
(V)
Excitation
storage
level (m/z)
MMA
m-clor (IS)
Malathion
9.0–10.8
10.8–11.4
11.4–18.0
60–305
125–295
90–185
295
286
173
+74
0
0
37.5
66.0
70.0
80
80
89
aExcitation
time = 40 µs; isolation window = 2 u; nonresonant waveform.
3. Calculate recovery rates and precision by spiking and analyzing 10 coverall pieces that
are 30 × 30 cm2 and 10 cotton gloves at low and high concentration levels considering the
calibration curves (e.g., 720 and 1440 µg/L) (see Note 13)
4. Calculate intermediate precision by analyzing three pieces of coverall and gloves spiked
as above every 2 wk for 4 mo (see Note 14).
5. State the stability of samples by spiking 36 pieces (30 × 30 cm2) of each garment with 180
µg of malathion. Store them in darkness at 4°C for 4 mo and analyze a set of three samples
of each sampling medium the first day and each week for 1 mo. The percentage recovery
by storage time is calculated by comparing the amount recovered with the amount recovered on the first day after spiking (see Note 15).
3.5.2. Inhalation Exposure Method
1. Prepare calibration curves by diluting pure standard solution and using extract of uncontaminated PUF containing the ISTD (e.g., 100 µg/L) for filling to volume. Calculate linear ranges, LOD, and LOQ for the air analysis method using the same procedure as in the
dermal exposure method (17).
2. Select the appropriate sorbent by stating the trapping efficiency of sorbents such as
Porapak R, Chromosorb 102, Supelpak, Amberlites XAD2 and XAD4, or PUF to sample
malathion in greenhouse air.
3. Build up a system for generating pesticide standard atmospheres as described in previous
work (14,15); in our case, we used a chromatographic oven with a 0.5-cm diameter hollow glass column. This system allows study of the influence of such variables as sampling volume, sampling time, sampling flow rate (e.g., 1 or 2 L/min), air relative humidity
(e.g., dry to 100% saturation), breakthrough volume (e.g., until 1 m3), and concentration
198
Egea González, Arrebola Liébanas, and Marín
Fig. 2. MS/MS and structural formulas. (Top) MMA; (Middle) clorpyrifos-methyl (IS); and
(Bottom) malathion.
of saturation (e.g., until 0.4 mg malathion), which have to be studied to validate the airsampling method.
4. Optimize the optimum conditions for achieving the complete volatilization of compounds
(see Note 16).
5. Obtain recovery rates by injecting in the device different volumes of a standard solution,
sampling a known volume of air using PUF plugs, and analyzing them. Check the influence of air humidity by saturating the air with water (see Note 17).
Exposure to Malathion and Metabolites
199
Table 3
Limits of Detection (LOD) and Quantification (LOQ) and Calibration Data
Compound
LOD (ng l-1)
LOQ (ng l-1)
a
b
MMA
Malathion
0.01
0.07
0.03
0.24
3.09
0.67
-0.08
-0.11
r2
0.9988
0.9831
a, intercept; b, slope; r2, determination coefficient.
6. Check the breakthrough volume by connecting two PUF plugs in series and sampling
different volumes of standard atmospheres (see Note 18). The high sorption capacity of
PUF allows sampling of a wide range of pesticide concentrations in the air.
7. Study the stability of samples at least for a 1-mo period, for example, by storing spiked
PUF plugs at ambient temperature 4 and –18°C) and checking recovery rates weekly
(three replicates each) (see Note 19).
3.5.3. Actual Exposure (Biomonitoring) Method
1. Calibrate using a blank urine sample spiked with each analyte, such as the range 1–500
µg/L, which is an adequate calibration range for the expected analyte concentrations in
urine samples.
2. Add the ISTD at 100 µg/L.
3. Obtain LODs and LOQs by analyzing 10 control urine samples without malathion contamination (Table 3). The best results are obtained for MMA-hexafluoroisopropyl derivatives (see Note 20). The LOD and LOQ are low enough for monitoring exposure of
pest control operators to malathion.
4. Use solid-phase extraction C18 cartridges for sample preparation because these eluates
are better suited for direct GC analysis, and they seldom require cleanup prior to GC
analysis. Liquid–liquid extraction must involve a cleanup step to avoid reduction in column efficiency and contamination of injector and ion trap (see Note 21).
5. State the dependence of extraction efficiency on the initial concentration of analytes by
spiking 10 urine samples with two different concentrations (e.g., 40 and 200 µg/L) and
checking recoveries (see Note 22).
3.6. Application of Methods
3.6.1. Field Trial Design
The exposure is assessed during a total of three applications of malathion in greenhouses (see Note 23). Three flat-roof polyethylene greenhouses (200-µm thick, 15 ×
40 × 2.50 m) located in Almería (Spain) were selected for the applications. The lateral
windows remained closed during the experiment, and climatological conditions are
registered. In the studied case, crops were green beans (cultivar Helda), tomato (cultivar Daniela), and cucumber (cultivar Almería). They were 2 m high with a 1-m
interrow distance, allowing the applicators to walk between each row during the applications. For spraying, a semistationary high-volume application equipment with one
circular nozzle operating at a flow rate of 4 L/min was used. The volume sprayed was
375 L in each case, corresponding approximately to a dose of 1 Kg/ha of malathion.
For the three applications, the spray liquid was prepared by dispersing 600 mL of
malathion 90 EL in a tank containing 400 L water.
200
Egea González, Arrebola Liébanas, and Marín
Each of the treatments should take at least 90 min. Applicators spray following an
application pattern, in this case walking between the rows and spraying one side of the
crop and returning along the same row and spraying the other side of the row. The
protection equipment of the three applicators consisted of a cotton t-shirt for the first
applicator and a full cotton–polyester coverall for the other two. All wore a mask. In
the case study, applicator 1 did not wear any protective equipment, so that potential
dermal exposure was not assessed.
As a case study, inhalation, internal dose, and potential dermal exposure to
malathion is determined for the applicators who wore personal protective equipment
(operators 2 and 3), the latter expressed as milliliters of spray tank deposited on the
garment per hour of application. The total volume of spray liquid deposited on the suit
of the operators and its distribution on the body was very similar for both applicators
(72.3 and 73.0 mL/h, respectively) (see Note 24).
Considering the distribution on the body, approx 75% of total potential exposure is
found on the lower body (thighs and lower legs), with both lower legs the most contaminated sections (approx 19 mL/h each leg). The highest amount of pesticide on
these regions was caused by the operators, who directed the spray gun to cut the flow
downward and pointing to the legs when they passed from one row to another row. On
the upper body (head, torso, back, and arms), the amount found on both applicators
was approx 25% of the total, with the left arm (4.8 and 5.1 mL/h, applicators 1 and 2,
respectively) and right arm (4.3 and 3.9 mL/h, respectively) the most exposed areas.
The concentrations of malathion in the breathing area during the application were
69.4 and 85.9 µg/m3 for applicators 2 and 3, respectively.
Concerning biomonitoring results, the proposed method has been applied to the
analysis of the urine of the three applicators. A number of samples ranging between 7
and 10 were collected from each worker in the 24 h after the applications. Malathion
and MMA were not detected in the samples taken as blanks before the applications.
Figure 3 shows the results obtained in the postapplication samples. It can be seen that
malathion was not detected, but its metabolite MMA was present in most of samples.
In all cases, the highest concentration found in urine was 5–8 h after spraying malathion
(except applicator 3, which was 20 h after application). The total amount of MMA
excreted was calculated considering the concentration found in each sample and the
volume collected. The total amount excreted ranged between 133.75 and 671.42 µg.
The highest amount determined corresponds to the urine of the applicator who did not
wear a cotton coverall during the experiment. This fact reveals the important use of
protective equipment (coverall) to spray malathion.
4. Notes
1. Workers are placed in a clean location, where coveralls are removed carefully and held in
the shade until dry, then the coveralls are extended on aluminum foil and rolled together,
avoiding contact between different parts of the suit. Store them in appropriate labeled
bags and store in a portable refrigerator until arrival at the laboratory.
2. The flow rate of the personal pump must be well calibrated, taking into account that the
final result of the air concentration is referred to the volume of air sampled. Keep records
of the certificates of calibration.
Exposure to Malathion and Metabolites
201
Fig. 3. Gas chromatogram of a urine sample containing (1) MMA and (2) IS.
3. Take the whole urine sample, indicating on the label the date and hour in which the sample
is taken.
4. The field quality control checks if any accidental contamination occurs by analyzing blank
samples of each sampling media, urine, PUF plugs, and coveralls. Prepare a clean location that is safe from contamination and is close to the greenhouse. Identical samples
(three replicates) are spiked in the field to check recoveries of each sampling media. The
sample of spray tank is collected (three replicates) directly from the nozzle about 15 min
from the start of application to ensure the homogeneity of the tank. The concentration of
the spray tank must be calculated to express the results as milliliters of spray tank per
hour of application.
5. The cartridge should not become dry during conditioning.
6. A derivatization step necessary for the analysis of metabolites because of the low volatility and high polarity of MMA is applied. Several derivatizing agents (e.g., fresh
diazomethane, Sigmasil A, and HFIP) could be used. In our case, the methyl esters obtained with diazomethane presented questionable stability and low sensitivity. In addition, it is a carcinogenic reactive. The trimethylsilyl esters obtained by a reaction of dried
eluent with Sigmasil A are much more sensitive than methyl derivatives, but the rest of
the derivatizing agent and its by-products yield several interfering peaks. So, we prefer
HFIP derivatives, which are produced by rapid coupling of the eluent with HFIP in the
presence of DIC reaction, are highly sensitive and do not produce interfering substances.
202
Egea González, Arrebola Liébanas, and Marín
7. A specific concentration of the solvent is unnecessary because the amount of pesticide on
the suit is high enough to be determined, and lower concentrations are not relevant for
exposure assessment.
8. For confidence in results, an in-house library is necessary, prepared in the working conditions of the MS/MS, with standards. The fit is a parameter to quantify the match between
the spectra of the library and the spectra of samples, with identical spectra having a fit
value of 1000.
9. The AGC continuously adapts in an automatic mode the ionization time of the ion trap
detector to avoid a reduction of the sensitivity. For the optimization of the sensitivity of
the detector, the trap should be filled with the target ions. A higher AGC target would
cause electrostatic interactions between the ions (space–charge effects), degrading performance.
10. The α- and β-MMA HFIP derivatives coelute in the selected GC conditions at the 9.79min retention time and can be quantified as the sum of both isomers. It can be seen in the
chromatogram (Fig. 4) that the retention times for the ISTD and malathion were 11.20
and 11.57 min, respectively.
11. The whole-body method shows a matrix effect in the quantification of the analyte because of the composition of the garment and the presence of products that are different
from the active ingredient in the commercial formulation of malathion. This effect is
shown when recovery rates of malathion from garments are determined in the method
validation. Recovery rates obtained when spiked samples are quantified with a calibration curve prepared in solvent are lower than the ones obtained when a matrix-matching
calibration is used (83.4 vs 90.2%, respectively). Thus, matrix-matching calibration was
chosen for the quantification of malathion in personal protective equipment samples.
Matrix-matching calibration is performed by preparing the working standard solutions
with an extract of an uncontaminated sample containing all the matrix components. The
use of matrix-matching calibration solutions is extended in the field of pesticide analysis.
Matrix may affect the analytical signal, introducing constant error when the intercept is
modified in relation with a calibration prepared in solvent or a proportional error when
the slope is modified or both if either intercept or slopes are different.
12. Lower limits achieved with this technique are low enough for exposure assessment purposes without the need for concentrating the sample extract. A linear range in high concentrations is useful to avoid dilutions and reanalysis of samples with a high
concentration.
13. In our case, recovery rates ranged between 90.2 and 103.2%, with the precision (expressed
as RSD) lower than 9.1% in all cases (Table 4).
14. Typical values for RSD of these measures is less than 15%.
15. In our case, it was above 91% in all cases during the period studied.
16. Try different oven injector and detector temperatures and different caudal of air; for example, by setting the chromatographic oven at 150°C and the injector and detector at
200°C, we achieved the volatilization of a known amount of pesticides. Passing air for 20
min at a flow rate of 2 L/min is enough to achieve the transfer of the analyte to the sorbent.
17. The recovery rate in the case study for malathion was 93.2% (5.7% RSD). Using PUF, no
influence of the air humidity on recovery rates obtained using dry or saturated air (93.2
and 94.1%, respectively) was observed.
18. A sampling method has to be versatile enough to sample air either with a high concentration of the target compound for a short period of time or with a low pesticide concentration for a longer period of time for application in different working conditions. For
Exposure to Malathion and Metabolites
203
Fig. 4. Gas chromatogram of a clean urine fortified with 10 mg L-1of each analyte: (1)
MMA; (2) IS; and (3) malathion.
example, in indoor applications the air concentration is expected to be higher than in the
outdoor environment when the method is applied for bystander exposure assessment. In
the first case, a short sampling time is appropriate, but in the second a high volume of air
should be sampled to determine trace levels. For example, testing should be done that
breakthrough does not occur by sampling for 30 min a standard atmosphere contaminated
with 10 mg/m3 of pesticides and for 8 h a standard atmosphere containing 0.2 µg/m3 of
pesticides.
19. In our case, we observed that light affects PUF plugs, resulting in a decrease of recovery rates.
20. Worse results are found if the analyses are carried out in full-scan mode because of the
presence of interfering substances, which coelute with the target analytes and are difficult
to remove by background subtraction. The average spectral fit obtained when analyzing
10 clean urine samples spiked with 200 ng/mL of each compound are 531 (MMA) and
397 (malathion), using full-scan mode, and 882 (MMA) and 820 (malathion) using MS/
MS mode. When MS/MS is used, if a coeluted interfering substance has the same identification ion as the analyte, it can be avoided using special experimental conditions for the
collision-induced dissociation and quantifying with a specific ion from the analyte.
21. After testing several elution solvents (acetone, n-hexane, diethyl ether, methanol, ethyl
acetate, and dichloromethane), the maximum elution is found with 10 mL of diethyl ether.
204
Egea González, Arrebola Liébanas, and Marín
Table 4
Recoveries (R%) and Relative Standard Deviation (RSD%)
Compound
Sample
Coverall
Air
Cotton gloves
Urine
Fortification
level
MMA
720 µg/L
1440 µg/L
0.2 µg/m3
10 µg/m3
720 µg/L
1440 µg/L
40 µg/L
200 µg/L
—
—
—
—
—
—
107.2 (6.6)
102.1 (6.1)
Malathion
90.2 (8.5)
91.7 (7.6)
93.2 (5.7)
94.1 (6.0)
103.2 (6.9)
98.4 (9.1)
114.3 (15.2)
109.4 (12.3)
n = 10.
22. In our case, the average recoveries obtained were between 102.1 and 114.3% in all cases.
The repeatability expressed as RSD was smaller than 15.2%. The results are summarized
in Table 4.
23. Keep a record of a plan of the greenhouse and plot and take pictures of the distribution of
crops (including height and interrow distance) and the dimensions of the greenhouse.
Obtain the flow rate of the gun by measuring the volume sprayed in a baker for 1 min by
replicating (at least three times) in the same operating conditions as during the pesticide
applications. Application times have to be well controlled to refer the results to the amount
of pesticide per hour of work. Take pictures of the applicators during the treatments and
describe carefully the application patterns. The applicators will fill an agreement form of
cooperation and a declaration that they have been informed about the potential risk of
their work.
24. We prefer the expression of results for potential dermal exposure in milliliters of spray
liquid contaminating the suit per hour because it is independent of the concentration of
spray liquid and gives the possibility of comparing with other experiments. To obtain
such information, the spray liquid must be well analyzed because the raw data from the
mass spectrometer provides the amount of pesticide as the milliliters of spray liquid obtained by dividing such raw data by the concentration of the spray. Other ways to express
such exposure is as milligrams of active ingredient per square centimeter of body or milligrams per hour.
Acknowledgments
This research was supported by the European Union Project ALFA (DG-12-RSMT)
and by the Comisión Interministerial de Ciencia y Tecnología (CICYT) Project
AMB97-1194-CE.
References
1. Commission of the European Communities, Council Directive 91/414/EEC, Official Journal of the European Communities No. L230, Luxembourg, 19 August 1991.
Exposure to Malathion and Metabolites
205
2. Chester, G. (1995) Methods of pesticide exposure assessment. In: Curry, P. B., ed., Plenum Press, New York, 179–215.
3. Fenske, R. A. (1993) Dermal exposure assessment techniques. Ann. Occup. Hyg. 37, 687–706.
4. Van Hemmen, J. J., Brouwer, D. H. (1995) Assessment of dermal exposure to chemicals.
Sci. Total Environ. 168, 131–141.
5. OECD, Guidance document for the conduct of studies of occupational exposure to pesticides during agricultural application, Series on Testing and Assessment No. 9, OECD/GD
(1997).
6. Castro Cano, M. L., Martínez Vidal, J. L., Egea González, F. J., Martínez Galera, M., Cruz
Márquez, M. (2000) Gas chromatographic method and whloe body dosimetry for assessing dermal exposure of greenhouse applicators to chlorpyrifos-methyl and fenitrothion.
Anal. Chim. Acta 423, 127–136.
7. Martínez Vidal, J. L., Glass, C. R., Egea González, F. J., Mathers, J. J., Castro Cano, M. L.
(1998) Techniques for potential dermal exposure assessment in Southern Europe. Proceedings of 9th International Congress, Pesticide Chemistry, The Royal Society of Chemistry and the IUPAC, London.
8. Martínez Vidal, J. L., Egea González, F. J., Glass, C. R., Martínez Galera, M., Castro
Cano, M. L. (1997) Analysis of lindane, α- and β-endosulfan and endosulfan sulfate in
greenhouse air by gas chromatography. J. Chromatogr. A 765, 99–108.
9. Egea González, F. J., Martínez Vidal, J. L., Castro Cano, M. L., Martínez Galera, M.
(1998) Levels of methamidophos in air and vegetables after greenhouse applications by
gas chromatography. J. Chromatogr. A 829, 251–258.
10. Doichuanngam, K., Thornhill, R. A. (1992) Penetration, excretion and metabolism of 14C
malathion in susceptible and resistant strains of Plutella xylostella Comp. Biochem.
Physiol. 101C, 583–588.
11. PSD, Pesticide Safety Directorate, Evaluation (1995) 135, UK MAFF.
12. Martínez Vidal, J. L., Arrebola, F. J., Fernández-Gutiérrez, A., Rams, M. A. (1998) Determination of endosulfan and its metabolites in human urine using gas chromatography–
tandem mass spectrometry. J. Chromatogr. B 719, 71–78.
13. Arrebola, F. J., Martínez Vidal, J. L., Fernández-Gutiérrez, A. (1999) Excretion study of
endosulfan in urine of a pest control operator. Toxicol. Letters 107, 15–20.
14. Arrebola, F. J., Martínez Vidal, J. L., Fernández-Gutiérrez, A., Akhtar, M. H. (1999) Monitoring of pyrethroid metabolites in human urine using solid-phase extraction followed by
gas chromatography-tandem mass spectrometry Anal. Chim. Acta. 401, 45–54.
15. Arrebola, F. J., Martínez Vidal, J. L., Fernández-Gutiérrez, A. (2001) Analysis of endosulfan and its metabolites in human serum using gas chromatography-tandem mass spectrometry (GC-MS/MS). J. Chromatogr. Sci. 39, 177–182.
16. Glastrup, J. (1998) Diazomethane preparation for gas chromatographic analysis. J.
Chromatogr. A. 827, 133–136.
17. González Casado, A., Cuadros Rodríguez, L., Alonso Hernández, E., Vílchez, J. L. (1996)
Estimate of gas chromatographic blanks Application to detection limits evaluation as recommended by IUPAC. J. Chromatogr. A. 726, 133–139.
Biomarkers of Exposure
207
16
Pesticides in Human Fat and Serum Samples
vs Total Effective Xenoestrogen Burden
Patricia Araque, Ana M. Soto, M. Fátima Olea-Serrano,
Carlos Sonnenschein, and Nicolas Olea
Summary
Tests to screen for estrogenicity and appropriate biomarkers of human exposure are
required for epidemiological studies of endocrine disruption. This requirement is
addressed here by developing a protocol that investigates bioaccumulated xenoestrogens
that are candidates for estrogenicity and assesses their combined estrogenic effect. It
comprises two major parts. The first part consists of an exhaustive chemical determination of the compounds under study, including procedures for the extraction, purification,
identification, and confirmation of the organochlorine pesticides and the quantification
of lipids in the samples. This goal is achieved using a semipreparative high-performance
liquid chromatographic (HPLC) separation of xenoestrogens from endogenous hormones
and subsequent chromatographic analysis of the fractions. The second part corresponds
to the testing of HPLC eluted fractions in the E-Screen test for estrogenicity, which
yields the estimation of the total effective xenoestrogen burden of each sample.
Key Words: Biomarkers; endocrine disruption; estrogenicity; exposure assessment;
xenoestrogens.
1. Introduction
Many studies of the association between environmental estrogens and adverse
health effects are based on the identification and quantification of chemical residues in
biological samples from human populations for the purpose of exposure assessment.
Despite the merits of this approach, it is proposed that study of the combined effect of
these compounds would be a better method for the assessment of exposure (1). We
have faced this challenge by developing a mixed methodology using semipreparative
high-performance liquid chromatography (HPLC), followed by chemical identification, quantification, and application of an E-Screen assay. By this means,
organohalogenated xenoestrogens are efficiently separated from ovarian estrogens,
and the exposure is quantitatively assessed in terms of hormonal activity (total effecFrom: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
207
208
Araque et al.
tive xenoestrogen burden, TEXB) (2–5). The distinction between the estrogenicity of
the fractionated tissue samples is of maximum interest because preliminary studies
have indicated that estrogenicity caused by organohalogenated chemicals is a risk factor for breast cancer (6).
In this chapter, the methodology proposed opens up a new approach to xenoestrogen
exposure assessment because it can focus on particular chemicals present in tissue
fractions. In fact, the list of xenoestrogens has been expanded using this method (7,8),
and chlorinated bisphenols, brominated nonylphenols, and organochlorine pesticides
have been identified as putative candidates responsible for the estrogenicity observed
in the bioassay. The semipreparative HPLC fractions that have been associated with
cancer risk contain organochlorine pesticides, among other organohalogenated chemicals. DDT (dichlordiphenyltrichlor) and derivatives are present in almost 100% of the
samples assayed in populations from southern Spain (9).
Natural endogenous estrogens together with phytoestrogens and nonhalogenated
xenoestrogens elute in fractions collected later in the chromatographic run. Natural
estrogens are produced and accumulate in adipose tissue (10,11), but the combined
role of natural estrogens and xenoestrogens in the estrogenicity of these fractions is
not known. In fact, estradiol esters, together with bisphenols, polyphenols,
phytoestrogens, mycoestrogens, and ovarian estrogens, are eligible candidates to explain the estrogenicity of these fractions.
Most human epidemiological studies of xenoestrogen exposure estimate the serum
or adipose levels of one chemical or of a small number of chemicals, ignoring the
impact of other chemicals and the cumulative effects of mixtures in the cell environment. The protocol presented here helps establish a relationship between the content
of xenoestrogens in adipose tissue and the risk of hormonal diseases because it measures the combined effects of organohalogenated xenoestrogens separately from the
hormonal activity of endogenous estrogens.
2. Materials
2.1. Equipment
1. HPLC (e.g., model 501, Waters, Milford, MA) equipped with two pumps and an injector
with 500-µL load capacity with an ultraviolet/visible detector (e.g., Waters model 490)
and Millennium Chromatography Manager software (Varian, Sunnyvale, CA). A column
packed with Lichrospher Si-60 with 5-µm particle size is used (e.g., Merck, Darmstadt,
Germany).
2. Gas chromatography with electron capture detector (GC/ECD; e.g., Varian 3350) with a
63Ni electron capture detector and Chromatography Manager software (e.g., Millennium).
A CP SIL8 CB column (30 m × 0.25 mm) is used.
3. GC with mass spectrometry (GC–MS; e.g., Saturn 2000, Varian) detector equipment and
CP5860 WCOT fused silica column (30 m × 0.25 mm).
4. Pyrex glass column (6 mm id) for the chromatography.
5. Sep-Pak Cartridge part WATO51900 (e.g., Waters).
6. Vortex mixer.
7. Rotavapor.
8. Titertek multiscan apparatus.
9. 0.22-mm filter (e.g., Millipore, Bedford, MA).
Biomarkers of Exposure
209
2.2. Chemicals
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
Methanol.
Isopropanol.
Hexane.
Ethanol.
Chloroform.
Hydrochloric acid.
Alumina 90 (70–230 mesh) (e.g., 1097, Merck).
Aldrin.
Dieldrin.
Endrin.
Lindane.
Methoxychlor.
Endosulfan I.
Endosulfan II.
Mirex.
p,p′-DDT.
o,p′-DDT.
o,p′-DDD.
Hexachlorobenzene.
Vinclozolin.
p,p′-Dichlorobenzophenone.
p,p′-DDE.
Endosulfan diol.
Endosulfan sulfate.
Endosulfan lactone .
Endosulfan ether.
MCF-7 cell line (Tufts University, School of Medicine, Boston, MA).
Dulbecco’s modification of Eagle’s medium (DME) (e.g., Norit A, Sigma Chemical,
Poole, UK).
Trypsin.
Charcoal.
Sulforhodamine-B (SRB).
17β-Estradiol (E2).
17β-Ethynylestradiol.
Progesterone.
Testosterone.
Nonylphenol.
Bisphenol A.
Genistein.
Dextran T-70.
Charcoal–dextran-treated human serum (CDHuS) (e.g., Irvine Scientific, Santa Ana, CA).
Phenol red-free DME (e.g., BioWittaker, Walkersville, MD).
Fetal bovine serum (FBS; e.g., BioWittaker).
Trichloracetic acid.
Acetic acid.
24-Well plates.
96-Well plates.
210
Araque et al.
3. Methods
The methods described below outline the chemical determination of organochlorine compounds and the biological assay.
3.1. Chemical Analysis
The steps described under Subheadings 3.1.1.–3.1.7. include the procedures for
the extraction, purification, identification, and confirmation of the organochlorine pesticides and the lipid determination. The samples are frozen at −80°C until their use
(see Notes 1 and 2).
3.1.1. Extraction of Xenoestrogens From Adipose Tissue
Biocumulative compounds are extracted from adipose tissue (reviewed in ref. 12,
with slight modifications).
1. Extract 200 mg adipose tissue with 20 mL hexane and elute in a glass column filled with
200 mg alumina previously hydrated with 5% distilled water (see Note 3).
2. Concentrate the eluate obtained at reduced pressure and then under a stream of nitrogen
to a volume of 1 mL or until total dryness (see Note 4).
The alumina (70–230 mesh) used in the extraction is previously dried at 600°C
for 4 h.
3.1.2. Extraction of Xenoestrogens From Serum
1. Incubate a 4-mL aliquot of serum with 2 mL methanol in a glass tube and shake the
mixture vigorously.
2. Add 5 mL ethylic ether and hexane (v/v) to the same tube, centrifuge for 10 min at 1800g,
and collect the organic phase in another tube.
3. Repeat step 2 three times.
4. Concentrate the organic phases under a stream of nitrogen to a volume of 1 mL.
5. Add to the residue 0.5 mL of H2SO4 and 1 mL hexane, centrifuge, and collect the
organic phase.
6. Add 1 mL hexane twice, centrifuge, and collect the organic phases.
7. Concentrate the organic phases under a stream of nitrogen until total dryness.
3.1.3. Semipreparative HPLC
A preparative liquid chromatographic method is used to separate xenoestrogens
from natural estrogens without destroying them. Extracts are eluted by a gradient program based on a previously described method (reviewed in ref. 13) with modifications: Two phases are used as the mobile phase: n-hexane (phase A) and
n-hexane:methanol:2-isopropanol (40:45:15 v/v/v) (phase B) at a flow rate of 1.0 mL/
min (13) (see Note 5). The normal phase column separates xenoestrogens according to
their polarity, with the most lipophilic compounds eluting in the shortest times (see
Note 6). This is described under Subheadings 3.1.3.1.–3.1.3.2. and includes the separation of the compounds in three fractions and an extensive separation in 32 fractions.
3.1.3.1. HPLC SEPARATION OF XENOESTROGENS IN THREE FRACTIONS
1. Resuspend the residue extracted in 1 mL hexane, mix, and inject 500 µL.
Biomarkers of Exposure
211
2. Collect the result of the first 11 min in a tube. This fraction is called the α-fraction.
3. Collect the fraction between minutes 11 and 13. This fraction is called the x fraction.
4. Collect the fraction between minutes 13 and 32 in another tube. This fraction is called the
β-fraction.
5. Inject the other 500 µL and repeat steps 2–4.
6. Join together the α-, x, and β-fractions collected in both injections.
7. Concentrate until total dryness under a stream of nitrogen.
3.1.3.2. EXTENSIVE HPLC SEPARATION
OF
XENOESTROGENS
When a much more concentrated fraction is needed or when a more exhaustive
method is required, an extensive fractionation method is proposed. The method is the
same as described under Subheading 3.1.3.1. with some modifications.
1. After extracting three extracts of 500 mg each from homogenized fat samples, resuspend
the concentrate in 3 mL hexane, mix, and inject 500 µL.
2. Pass through the HPLC column and collect fractions of 1 mL from min 1 to 32.
3. Inject an additional 500 µL and repeat step 2, collecting minute 1 with min 1 of step 2,
and so on.
4. Repeat step 3 four additional times and join together the fractions collected at the same
times. Thus, each fat sample gives 32 fractions of 6 mL that correspond to 1500 mg of tissue.
3.1.4. Cleanup of Serum
The organic extracts are purified using silica Sep-Pak. The extract of serum is dried
in a tube (tube A).
1. Treat the cartridge with 2 mL hexane to condition the column.
2. Eluate the organic extract by adding 10 mL hexane to tube A (see Note 7), mix, add to the
cartridge, and collect the eluate in another glass tube (tube B).
3. Add 10 mL hexane:methanol:isopropanol (45:40:15 v/v/v) to tube A and repeat step 2.
4. Concentrate the eluate obtained at reduced pressure in a rotavapor and then under a stream
of nitrogen to a volume of 1 mL or until total dryness (see Note 4).
3.1.5. Identification and Quantification of Organochlorine
Compounds by GC
The α-fraction from HPLC and the serum eluated from Sep-Pak are identified using
GC/ECD (see Notes 8 and 9).
1. The HPLC α-fraction and serum extracts are dissolved, respectively, in 100 µL and 1 mL
of hexane labeled with p,p′-dichlorobenzophenone internal standard.
2. Mix vigorously.
3. Inject 1 µL of the solution into the chromatograph.
4. Quantitative analysis, internal standard method: p,p′-dichlorobenzophenone is selected
as THE internal standard because it appears in the chromatogram near the components
under study, is chemically similar to these components, and is expressed in comparable
concentrations. The reproducibility of the internal standard is excellent, and the calibration curve has a fit of R2 = 0.988 in a range of concentrations between 0.03 and 1.50 µg/
mL. The concentrations of the pattern solutions for the tested products are between 0.02
and 0.0001 µg/mL. The detection limits of the compounds studied have been established
following International Union of Pure and Applied Chemistry (IUPAC) norms, obtaining
212
Araque et al.
values of 0.1 to 3.0 ng/mL. Once the response factor is calculated, the equations of the
curves for each product are obtained, and the corresponding correlation coefficient is
calculated from the ratio of the areas to the concentrations, with a value more than 0.922.
3.1.6. Confirmation by GC/MS
The presence of organochlorines in HPLC α-fraction and in serum eluate is confirmed by GC–MS (see Note 10).
1. Inject 2 µL of the solution prepared under Subheading 3.1.5. (see Note 11).
2. Dry until total dryness to store.
3.1.7. Lipid Determination
Total lipid content is quantified gravimetrically.
1. Weigh the flask in which the extraction is to be performed (empty flask weight).
2. Homogenize 100 mg of adipose tissue in 5 mL of chloroform:methanol:hydrochloric acid
(20:10:0.1) in a glass potter and pass to a centrifuge tube.
3. Extract again with 5 mL of chloroform:methanol:hydrochloric acid (20:10:0.1) and pass
to another centrifuge tube.
4. Add 5 mL of 0.1 N HCl to each tube.
5. Centrifuge at 1800g for 10 min.
6. Collect the organic phases in the previously weighed flask.
7. Extract the nonorganic phases again and add them to the first extraction products.
8. Weigh the flask (full flask weight).
Calculate percentage lipid according to the formula
Filled flask weight (g) – Empty flask weight (g)
Lipid % = __________________________________________ × 100
Adipose tissue weight (g)
The total lipid content is expressed in grams of lipid per grams of adipose tissue.
3.2. Bioassay for Measuring Estrogenicity
The steps described under Subheadings 3.2.1.–3.2.5. include the description of the
human breast cancer cell line used, the procedures for the E-Screen assay, the standard
curve of estradiol, and the description of the transformation of cell proliferation into
estradiol equivalent units.
3.2.1. MCF-7 Cell Line
Cloned MCF-7 cancer cells are grown for routine maintenance in DME supplemented with 5% FBS in an atmosphere of 5% CO2/95% air under saturating humidity
at 37°C. The cells are subcultured at weekly intervals using a mixture of 0.05% trypsin
and 0.01% EDTA.
3.2.2. Charcoal–Dextran Treatment of Serum
1. Add calcium chloride to outdated plasma to a final concentration of 30 mM to facilitate
clot formation.
2. Remove sex steroids from serum by charcoal–dextran stripping.
3. Prepare a suspension of 5% charcoal with 0.5% dextran T-70.
Biomarkers of Exposure
213
4. Centrifuge at 1000g for 10-min aliquots of the charcoal–dextran suspension of similar
volume to the serum aliquot to be processed.
5. Aspirate supernatants.
6. Mix serum aliquots with the charcoal pellets.
7. Maintain this charcoal–serum mixture in suspension by rolling at 6 cycles/min at 37°C
for 1 h.
8. Centrifuge the suspension at 1000g for 20 min.
9. Filter the supernatants through a 0.22-µm filter.
10. Store the CDHuS at −20°C until needed.
3.2.3. Cell Proliferation Experiments
MCF-7 cells are used in the test of estrogenicity according to a technique slightly
modified (reviewed in ref. 14) from that originally described (reviewed in ref. 10).
1. Trypsinize cells and plate in 24-well plates at initial concentrations of 20,000 cells per
well in 5% FBS in DME.
2. Allow the cells to attach for 24 h.
3. Resuspend α-, x, and β-fractions obtained by preparative HPLC chromatography in 5 mL
CDHuS-supplemented phenol red-free medium.
4. Shake vigorously and leave to rest for 30 min.
5. Filter through a 0.22-µm filter.
6. Replace the seeding medium with 10% CDHuS-supplemented phenol red-free DME.
7. Test the product of step 5 in the assay for estrogenicity at dilutions from 1:1 to 1:10. (see
Note 12).
8. Stop the assay after 144 h by removing medium from wells.
9. Fix the cells and stain them with SRB.
10. Treat the cells with cold 10% trichloroacetic acid and incubate at 4°C for 30 min.
11. Wash the cells five times with tap water and leave to dry.
12. Stain for 10 min trichloroacetic-fixed cells with 0.4% (w/v) SRB dissolved in 1% acetic
acid.
13. Rinse the wells with 1% acetic acid and air dry.
14. Dissolve the bound dye with 10 mM Tris-HCl base, pH 10.7, in a shaker for 20 min.
15. Transfer aliquots to a 96-well plate.
16. Read in a Titertek Multiscan apparatus at 492 nm.
The linearity of the SRB assay with cell number is verified prior to the cell growth
experiments.
3.2.4. Estradiol Dose–Response
The first step toward the estradiol dose–response is to define the dose-proliferative
response curve for estradiol in MCF-7 cells as a reference curve (reviewed in ref. 9).
At concentrations below 1 pM estradiol, equivalent to 1 fmol in 1 mL of culture medium, mean cell numbers do not significantly differ from those in the steroid-free
control. Thus, 1 fmol estradiol/well is determined as the lowest detectable amount of
estrogen in this assay.
3.2.5. Estimation of the TEXB
The 100% proliferative effect (PE) is calculated as the ratio between the highest
cell yield obtained with 50 pM of estradiol and the proliferation of hormone-free control cells. The PE of α- and β-fractions was referred to the maximal PE obtained with
214
Araque et al.
estradiol and transformed into estradiol equivalent units (Eeq) by reading from the
dose–response curve prepared using estradiol (concentration range 0.1 pM to 10 nM)
(reviewed in ref. 15).
The TEXB is then expressed as the concentration of estradiol in picomolar units
that results in a similar relative PE to that obtained with the α- and β-fractions and
referred to the percentage of lipid in the sample.
4. Notes
1. Adipose tissue samples are taken from patients undergoing surgical treatments for breast
cancer. Breast adipose tissues are obtained in the operating room during the course of
surgery of primary lesions. Tissues are placed in a glass vial on ice, coded, and frozen to
−80°C, always within 30 min of excision or aspiration.
2. Blood is obtained by venipuncture before surgery using glass tubes with no substance
added. Serum is separated from cells by centrifugation, divided into 4-mL aliquots, coded,
and stored at −80°C until analysis.
3. For successful extraction, it is most important to extract the adipose tissue gradually,
adding the hexane to the potter in 3-mL amounts.
4. The extract obtained should be concentrated to total dryness if processing is not immediately performed.
5. The working conditions are as follows: gradient t = 0 min, 100% phase A; t = 17 min,
60% phase A; t = 22 min, 100% phase B; t = 32 min, 100% phase A.
6. The α-fraction contains organochlorine pesticides; the β-fraction contains natural endogenous estrogens together with phytoestrogens and nonhalogenated xenoestrogens.
7. The hexane and hexane:methanol:isopropanol should be added to tube A in 2-mL amounts
to ensure better purification.
8. Working conditions are as follows: ECD at 300°C; injector at 250°C; for the program,
initial T = 130°C (1 min), 20°C/min to 150°C, 10°C/min to 200°C, 20°C/min to 260°C
(20 min). The carrier gas is nitrogen at a flow of 30 mL/min, and the auxiliary gas is
nitrogen at a flow of 40 mL/min
9. The detection limits are between 0.1 and 1 ng/mL.
10. The working conditions are as follows: 250°C injector temperature; 50°C initial column
temperature (2 min), 30°C/min to 185°C (5.5 min), 2°C/min to 250°C (32.5 min), and finally 30°C/min to 300°C (6.67 min). The carrier gas is helium with an injector flow of 1 mL/
min. Manifold, transfer-line, and trap temperatures are 50, 230, and 200°C, respectively.
11. If the GC–MS is performed immediately after the injection into the GC–ECD, it is not
necessary to dry or resuspend again in hexane.
12. Each sample is done in triplicate with a negative (vehicle) and a positive (10 pM estradiol) control in each plate.
References
1. Rice, C., Birnbaum, L. S., Cogliano, J., et al. (2003) Exposure assessment for endocrine
disruptors: some considerations in the design of studies. Environ. Health Perspect. 111,
1683–1690.
2. Damstra, T., Barlow, S., Bergman, A., Kavlock, R., and Van der Kraak, G. (eds.). (2002)
Global Assessment of the State-of-the-Science of Endocrine Disruptors. WHO, Geneva.
3. Herbs, A. L., Ulfelder, H., and Poskanzer, D. C. (1971) Adenocarcinoma of the vagina. N.
Engl. J. Med. 284, 878–881.
Biomarkers of Exposure
215
4. Colborn, T., vom Saal, F. S., and Soto, A. M. (1993) Developmental effects of endocrinedisrupting chemicals in wildlife and humans. Environ. Health Perspect. 101, 378–384.
5. Snedeker, S. M. (2001) Pesticides and breast cancer risk: a review of DDT, DDE, and
dieldrin. Environ. Health Perspect. 109(Suppl. 1), 35–47.
6. Sonnenschein, C. and Soto, A. M. (1998) An updated review of environmental estrogen
and androgen mimics and antagonists. J. Steroid Biochem. Mol. Biol. 65, 143–150.
7. Borgert, C. J., LaKind, J. S., and Witorsch, R. J. (2003) A critical review of methods for
comparing estrogenic activity of endogenous and exogenous chemicals in human milk and
infant formula. Environ. Health Perspect. 111, 1020–1036.
8. Sonnenschein, C., Soto, A. M., Fernandez, M. F., Olea, N., Olea-Serrano, M. F., and RuizLopez, M. D. (1995) Development of a marker of estrogenic exposure in human serum.
Clin. Chem. 41(12 Pt. 2), 1888–1895.
9. Rivas, A., Fernandez, M. F., Cerrillo, I., et al. (2001) Human exposure to endocrine disrupters: standardisation of a marker of estrogenic exposure in adipose tissue. APMIS 109,
185–197.
10. Soto, A., Lin, T. M., and Justicia, H. (1992) An “in culture” bioassay to assess the estrogenicity of xenobiotics (E-SCRREEN), in Chemically Induced Alterations in Sexual Development: The Wildlife/Human Connection (Colborn, T. and Clement, C., eds.), Princeton
Scientific, Princeton, NJ, pp. 295–309.
11. Nilsson, S. and Gustafsson, J. A. (2002) Estrogen receptor action. Crit. Rev. Eukaryot.
Gene Expr. 12, 237–257.
12. Okond’ahoka, O., Lavaur, E., Le Sech, J., Phu Lich, N., and Le Moan, G. (1984) Etude de
l’impregnation humaine par les pesticids organo-halogenes au Zaire. Ann. Fals Exp. Chim.
77, 531–538.
13. Medina, M. B. and Sherman, J. T. (1986) High performance liquid chromatographic separation of anabolic oestrogens and ultraviolet detection of 17 β-oestradiol, zeranol,
diethylstilboestrol or zearalenone in avian muscle tissue extracts. Food Addit. Contam. 3,
263–272.
14. Villalobos, M., Olea, N., Brotons, J. A., Olea-Serrano, M. F., Ruiz de Almodovar, J. M.,
and Pedraza, V. (1995) The E-screen assay: a comparison of different MCF7 cell stocks.
Environ. Health Perspec. 103, 844–850.
Internal Quality Criteria
219
17
Quality Criteria in Pesticide Analysis
Antonia Garrido Frenich, José L. Martínez Vidal, Francisco J. Egea
González, and Francisco J. Arrebola Liébanas
Summary
There is an increasing concern in pesticide residue analysis laboratories to ensure the
quality of their analytical results. Internal quality control (IQC) measures are an essential element to ensure reliable results because they allow both the continuous monitoring
of the process and measurements and the elimination of causes of unsatisfactory performance. IQC measures involve the use of blanks, certified reference materials (CRMs),
quality control samples, calibrating standards, spiked samples, replicated samples, and
blind samples. IQC measures are included in the analytical batch, but it is important not
to forget that IQC criteria must be consistent with the cost of analyses, so that the number of IQC measures must not exceed 10% of the total number of samples. Finally, quality criteria in the identification and confirmation of pesticides are considered.
Key Words: Confirmation; identification; internal quality control; pesticides.
1. Introduction
Analytical laboratories, as entities that provide analytical information, have developed a quality system to ensure the quality of their results. There are three basic elements of that system: quality assurance (QA) (1,2), quality control, and quality
assessment. Quality management is related to planification, assurance, control, and
assessment of quality activities. QA is the essential organizational infrastructure that
underlies all reliable analytical measurements. It is concerned with achieving, among
others, appropriate levels in matters such as staff training and management; adequacy
of the laboratory environment; safety; storage, integrity, and identity of samples;
record keeping; maintenance and calibration of instruments; and use of technically
validated and properly documented methods to obtain measurement traceability. These
practices have been recognized as essential. However, the adequate introduction and
management of these elements are not enough to guarantee the quality of analytical
results obtained at a given time. For this aim, specific activities are also necessary that,
in the framework of the quality system, are termed quality control activities.
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
219
220
Garrido Frenich et al.
The International Standards Organization (ISO) 8402 (3) defines quality control as
the techniques and activities of operative character used to fulfill the requirements of
quality. It is a general definition that shows that quality control refers to operativetype activities; organizational and management activities would correspond to the QA
concept.
In the context of analytical laboratories (4), internal quality control (IQC) is defined as the set of procedures undertaken by laboratory staff for the continuous monitoring of an operation and the measurements to decide whether results are reliable
enough to be released. IQC is characterized as the responsibility of the staff (analysts,
technicians) who directly carry out the activities.
In the literature, IQC generally is also termed quality control, although it should not
be confused with external quality control (EQC). This provides both evidence of the
quality of the laboratory’s performance and individual analyst proficiency. Typical
EQC activities are proficiency testing or collaborative studies. Although important,
participation in EQC activities is not a substitute for IQC measures or vice versa.
IQC includes measures that involve both monitoring the process and eliminating
causes of unsatisfactory performance (5). IQC activities must be sufficient to ensure
that the measurement chemical processes (MCPs) are under statistical control (6). This
goal is achieved when the quality level is good enough to detect whether unexpected
or unwanted changes have occurred during analysis of samples. The frequency of IQC
measures will depend on the volume of work, the experience of the analysts, and costs
involved in ensuring that the analytical system is under control. Some IQC operations
must be carried out routinely (e.g., daily quality checks through control charting).
IQC is an important determinant of the quality of data, and as such is recognized by
international organizations and accrediting agencies. IQC is based on a number of
measures that an analyst can make to ensure the data obtained are fit for their intended
purpose. So, IQC measures enable the analyst to accept a result or reject it and repeat
the analysis. IQC influences the accuracy and the precision of the measurements.
IQC is undertaken by the inclusion of particular samples in the analytical sequence
and by replicate analysis. Some measures of IQC are the analysis of blanks, quality control samples, certified reference material (CRM) or in-house reference material, blind
samples, replicate samples, calibrating standards, and laboratory or field-spiked samples.
QA and quality control are essential in helping analytical chemists deliver reliable
and meaningful answers to their customers. Analytical results delivered without any
quality statements now should be considered counterproductive data.
This chapter describes IQC measures as well as other basic activities necessary to
obtain quality measurements in pesticide analysis.
2. Basic Activities in Pesticide Analysis
1. The laboratory must be distributed in well-defined work areas to avoid contamination of
standards, samples, and extracts. So, separate areas for sample reception, processing, and
extraction and for the storage and preparation of analytical standards must be defined.
2. All equipment (measurement instruments, balances, flask, pipets) must be calibrated regularly (to establish the relation between the value indicated by the equipment and the value
indicated by a standard) and records of calibration maintained. In addition, measurement
Internal Quality Criteria
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
221
instruments should be maintained (to avoid breakdown and bad operation) and verified
(to check that some requirements are fulfilled) according to an established program. These
activities are essential to ensure the traceability of measurements.
Laboratory operations should be carried out according to the requirements of international standards, such as ISO 17025, ISO 9001:2000, or good laboratory practices.
Analytical methods used must be validated in agreement with intended purpose and documented as standard operating procedures (SOPs).
The laboratory should analyze appropriate CRMs, when available, and participate in
interlaboratory studies when appropriate samples are available that may be used as indicators of the comparability of data generated by the laboratory.
Personnel must be qualified, trained, and motivated. The required qualification, apart
from personnel experience, is obtained through job-oriented internal and external
trainings. Staff must be trained in the appropriate laboratory skills, in the use of specialized analytical instrumentation, and in the evaluation and interpretation of the data they
produce. Training and experience are documented in records that must be kept for all
staff. Personnel must not carry out a sample analysis without demonstrating previously
its ability to give good results.
Sampling, usually done by the customer or by the laboratory, requires highly specialized
analytical expertise. The laboratory should state in the report that the samples were analyzed as received if it was not responsible for sampling. Samples must be transported to
the laboratory in clean containers in no more than 1 d. When it is not possible to send
samples of fresh products to the laboratory within a few hours, they must be frozen and
transported in boxes containing dry ice to avoid thawing. Samples must be clearly identified by legible labels that cannot be detached easily.
Samples preferably must be processed within 1 or 2 d of sample receipt. Analysis of
samples should be carried out immediately after processing unless it can be demonstrated
that residues in extracts are not affected by longer storage (freezer, overnight storage at
1–5°C in the dark). Analysis of certain volatile or labile pesticides must be carried out
quickly and without storage of the samples. The use of a smaller test portion may increase
the uncertainty of the MCP.
The quality of reagents used must be appropriate for the test concerned. The grade of any
reagent used should be stated in the SOP. If the quality of reagents is critical to a test,
changes in supply batches should be verified.
Reference materials, CRMs, and pesticide standards must be unambiguously identified
on receipt and accompanying certificates stored.
Reagents prepared in the laboratory should be labeled to identify compound, concentration, solvent, and date of preparation or expiry. Also, the analyst who prepares the reagent shall be identifiable either from the label or from records.
Individual primary calibration solutions, generally 100–1000 mg/L, for the majority of
the pesticides are stable for several months if kept at low temperature (in a refrigerator or
freezer) in the dark and sealed against evaporation. For its preparation, not less than about
10 mg of the pesticide standard must be weighed. In any case, the stability of the standard
solutions must be checked and documented.
Methods developed in-house must be fully validated (7–14) using internationally accepted
criteria (15–17). The laboratory must verify its capability to obtain good results when
using standard methods before any sample is analyzed. For that, the laboratory must recalculate the characteristic parameters of the standard method to decide if it is “fit to
purpose.” It may be possible to incorporate a new analyte to an existing method, or this
method may be used to analyze a different matrix with appropriate additional validation.
222
Garrido Frenich et al.
14. The validation process of the method has to include the estimation of uncertainty (18–21)
as an essential tool for ongoing IQC. The uncertainty of the analytical method is indispensable in establishing the comparability of the measurement.
15. The laboratory’s quality system must attend to compliance with safety, chemical hygiene,
and all applicable regulations. SOPs should include the safe disposal of all waste materials.
16. The laboratory environment should be clean enough to ensure that it has no influence on
analytical measurements.
17. IQC must be applied after analyzing a number of samples. It is very important to establish
the right set size, based on experimental studies, to demonstrate that the MCP does not
suffer changes intraset. On the other hand, the application of IQC should be consistent
with the cost of analysis, so the number of analyses because of IQC must not exceed 10%
of the total number of samples. In routine analysis, an IQC level of 5% is reasonable;
however, for complex MCP, levels between 20 and 50% are not unusual.
3. Internal Quality Control Measures
Quality control is a key element for ensuring reliable results. IQC measures (22)
must be included in the analytical batches to enable analysts to decide whether the
batches satisfy the preset quality criteria and that a set of the results can be accepted.
IQC measures involve the use of blanks, CRMs, calibrating standards, spiked samples,
replicate samples, and blind samples, among others (Fig. 1).
3.1. Blanks
Laboratory reagent blanks eliminate false positives by contamination in the extraction process, instruments, or chemicals used. A matrix blank has to be analyzed to
detect interferences of sample matrix. If a matrix blank is not available, the use of a
simulated home-made matrix is allowed (23). Analyses of blanks with each set of
samples ensures that the analytical signal is attributable just to the analyte (24,25).
3.2. CRMs and Quality Control Samples
Reference materials can be used to study the variation between batches of samples,
verifying the comparability of the measures. However, CRMs are expensive to use in
daily IQC of a laboratory. In addition, few reference material producers are dedicated
to pesticides in water or foods. This lack of reference materials may be overcome by
the preparation and use of home-made reference materials (QC sample), spiking a
blank sample matrix with 5–10% of the target pesticides. This sample, properly stored,
must be checked for stability and homogeneity and then used as a quality control
sample. This sample must be analyzed every day by applying the analytical method,
providing additional information about instrument performance (instrument sensitivity, column performance, etc.).
The variation in the data obtained from the analysis of the quality control sample is
normally monitored on a quality control chart, setting warning limits at ±2s (s = standard deviation of at least 10 replicate analyses) and action limits at ±3s. To set realistic
limits, the mean and standard deviation must include the effect of interday precision,
considering variations of analyst, chemicals, standards, and so on. Some rules based
on statistical criteria may be applied to the interpretation of data trends in quality
control charts (8,26,27).
Internal Quality Criteria
223
Fig. 1. Basic components of the IQC.
223
224
Garrido Frenich et al.
3.3. Calibrating Standards
Methodological calibration involves the use of chemical calibrating standards,
which may be analyzed separately from samples (external standards) or as part of the
samples (internal standards). A calibration curve must be carried out for every batch
of samples. A minimum of three standard concentrations, in routine use, has to be used
for the calibration of each pesticide. The first of them has to be equal or preferably
lower than the maximum residue level (MRL) allowed for each pesticide in the target
matrices. This point must be higher than or equal to the limit of quantitation (LOQ).
The fit (linear, quadratic, etc.) of the calibration function must be inspected visually to
ensure that it is satisfactory; also, the lack-of-fit test (8) may be used if replicate calibration points are available. Individual points of the calibration curve must not differ
more than ±20% (±10% if the MRL is exceeded or approached). So, the difference
between the concentration of analyte in each calibrating standard and the concentration calculated from the calibration curve must be lower than ±20% (±10% if the MRL
is exceeded or approached). In contrast, a more appropriate fit must be used or the
individual points must be repeated.
Calibration can also be performed by interpolation between two concentration levels. It is acceptable when the mean response factors (signal-to-concentration ratio),
also called sensitivity, calculated from replicate analysis at each level indicate good
linearity of the response. The higher response factor should not be more than 120% of
the lower one (110% if the MRL is exceeded or approached).
Finally, single-level calibration is also used and may provide more accurate results
than multilevel calibration if the detector response varies with the time. The sample
response should be within ±50% (±10% if the MRL is exceeded) of the calibration
response.
The slopes of the different calibration graphs must not differ significantly from the
value found in the validation of the method, when the LOQs were established, because
of the dependence of the quality of an analytical method for compounds at trace levels
of its sensitivity. A decrease in the slope of the calibration curve may be critical when
analyzing samples with analyte concentrations close to the LOQs. Figure 2a shows
calibration curves with slopes that are 30, 20, 15, and 10% lower than the slope value
found in the validation. These variations involve a decrease of the LOQ level according to its definition (27,28) of 45, 25, 18, and 12%, respectively (Fig. 2b). So, the
slope of the daily calibration curve must not be lower than 10% of the slope value
found in the validation step of the analytical method, mainly working close to the
LOQs. In a consistent way, a good option may be not to establish the characteristic
parameters of the analytical method (i.e., LOQs) using the best sensitivity of the MCP,
but instead a more realistic option should be taken into account, considering that, after
a long period of time, decreases in the capability of the method to carry out analytical
measures occur because of replacement of equipment parts, variations in the sample
matrix, changes in the environment, among others.
On the other hand, matrix influence (8,29) on the calibration step has to be considered at method validation. Unfortunately, the reliability of the above-described calibration approaches may not be absolute when the sample matrix is too complex and
Internal Quality Criteria
225
Fig. 2. Calibration plots with different slopes: (1) value found in the validation of the method
and varying by (2) 10%, (3) 15%, (4) 20%, and (5) 30% considering (A) all the linear range and
(B) the three first points of the linear range.
226
Garrido Frenich et al.
standards are prepared in solvent. If this is not taken into account in the developed
method, then systematic errors can affect the result and cause bias in the final results.
Matrix effect may affect both the slope and the intercept of the calibration line. In
these cases, calibration using external standards prepared in the sample matrix (6,30–
34) or standard addition procedure are then a recommended choice to avoid mistakes
in the quantitation step. However, they also suffer some problems, such as that different commodities and different concentrations of matrix may give matrix effects of
different magnitudes or the difficulties of obtaining a blank matrix for every sample
type. Most of them would be avoided if a matrix, selected as representative matrix,
would be used for calibration purposes for the same and similar matrices.
3.4. Spiked Samples
Recoveries measured from spiked matrix blanks are used to check the extraction
efficiency in each batch of samples (because of the lack of reference materials for
pesticide analysis). If the detection system allows, all recoveries may be combined in
a single analysis by adding all analytes to a matrix blank at a concentration level about
30% above the LOQ. This level of addition may be varied to have information over a
range of concentrations.
Mean recovery values are acceptable at the validation step within the range 70–
110% (16). Routine recovery values are acceptable in the range 60–140%, but recoveries for pesticides detected in the analyzed samples must be within the 70–110%
range. If a routine recovery result is too low, the batch of samples should be reanalyzed. If the routine recovery is too high and no positive residues are detected, it is not
necessary to reanalyze the samples, although high recovery should be investigated.
The above criteria about recoveries cannot be applied to solid-phase microextraction
and head space analyses.
An analyte surrogate can be added to all the samples before starting the analysis to
demonstrate that the MCP has been satisfactory for each sample and that mistakes
have been avoided (i.e., to monitor method performance for each sample).
3.5. Replicated Samples
Replicated samples provide a less-formal means for checking for drift than quality
control samples. Normally, the replicated sample is a conventional sample for which
the analysis is repeated later within the batch of samples or perhaps in different batches.
The results obtained from the analysis of these samples must be comparable, taking
into account the uncertainty of the method. They are located in the batch every certain
number of samples (i.e., 1 in every 10 samples). The analyst knows when replicated
samples are included in the batch.
3.6. Blind Samples
Blind samples are replicate samples placed in the analytical batch without being known
by the analyst. They may be sent by the laboratory management to check a particular
system or by the customer to check the laboratory. Together with replicated samples, they
are used to check inter- or intrabatch precision. In this way, blind samples are complementary to replicated samples, providing information about an analyst’s proficiency.
Internal Quality Criteria
227
Results of the replicated and blind samples have to be in agreement with the original analysis in the range established by the uncertainty of the method.
4. Quality Criteria in the Identification and Confirmation of Pesticide Residues
4.1. Identification
For the retention time windows (RTWs), reproducible retention times are important in helping to identify an analyte in chromatographic techniques. For that, it is
recommended to use relative retention data expressed with respect to the retention
time of a standard substance (e.g., internal standard). RTWs are calculated by injection (N = 10) of a calibrating standard of an analyte and are defined as retention time
averages plus or minus three standard deviations of retention time. Identification criteria set a RTW based on the reference retention time within which the analyte peak for
a real sample must occur (35).
4.2 Approaches to Confirmation
Confirmation of results is an essential step. In the case of negative results, the results are considered confirmed if the recovery result is acceptable for the batch in
which the samples are analyzed. This is also of application in the case of positive
results, but they require additional qualitative and quantitative confirmation. Several
alternatives may be used in chromatographic techniques, depending on the detection
method: liquid chromatography (LC) with diode array detection if the ultraviolet spectrum is characteristic; LC with ultraviolet/visible investigation or fluorescence in combination with other techniques; gas chromatography with electron capture detection,
nitrogenous phosphorus detection, or flame phosphorus detection applying stationary
or mobile phases of different selectivity or other techniques (36). However, mass spectrometry (MS) is often used for the confirmation of organic microcontaminants because it can provide potentially unequivocal confirmation.
4.2.1. Confirmation by MS
MS detection is carried out by recording full-scan mass spectra or selected ion
monitoring (SIM), as well as MS-MSn techniques such as selected reaction monitoring or other suitable MS or tandem MS (MS/MS) techniques in combination with
appropriate ionization modes such as electron impact (EI) or chemical ionization.
4.2.1.1. FULL SCAN
The confirmation of the results must be performed by comparing the spectrum of
the previously identified compound with that generated using the instrument employed
for analysis of the samples. It must be considered that distortion of ion ratios is observed when analyte overloads the detector, and background spectra are not carefully
subtracted to obtain representative spectra of the chromatographic peaks.
The target spectra must contain at least four measured diagnostic ions (the molecular ion, characteristic adducts of the molecular ion, characteristic fragment, and isotope ions) with a relative intensity of more than 10% in the reference spectrum of the
calibration standard. The spectrum may be accepted as sufficient evidence of identity
228
Garrido Frenich et al.
when ions unrelated to the analyte in a full-scan spectrum (i.e., from m/z 50 to 50 mass
units greater than the molecular ion) present relative intensities that do not exceed
25% (for EI) or 10% (for other ionization methods). When computer-aided library
searching is used, the comparison of mass spectral data has to exceed a critical match
factor (fit threshold) that shall be determined during the validation process for every
analyte. Such a factor must be calculated by considering variability caused by the
sample matrix and the detector performance. The fit thresholds are usually scaled to
1000 for the best match (identical spectra). The critical match factor shall be set by the
average fit of the spectra from 10 injections of the midlevel standard of calibration and
subtracting a factor that considers the variability above described (usually 250 units).
4.2.1.2. SELECTED ION MONITORING AND MS/MS
The molecular ion shall preferably be one of the selected diagnostic ions, which
should not exclusively originate from the same part of the molecule and must have a
signal-to-noise ratio of 3 or greater. Two ions of m/z > 200 or three ions of m/z > 100
are the minimum data requirement when SIM mode is used. The most abundant ion
that shows no evidence of chromatographic interference and the best signal-to-noise
ratio should normally be used for quantification. When full-scan and SIM modes are
employed, the relative intensity of the detected ions shall correspond to those of the
calibration standard at comparable concentrations and measured under the same experimental conditions and be within a tolerance of ±20%.
The acquisition of spectra performed by MS/EI or MS/MS/EI may provide good
evidence of identity and quantity in many cases. However, when mass spectra are produced by other process such as chemical ionization or atmospheric pressure ionization,
further evidence may be required because of the simpleness of the obtained mass spectra. The additional evidence can be sought using (1) a different chromatographic separation system; (2) a different ionization technique; (3) MS/MS; (4) medium/
high-resolution MS; or (5) altering fragmentation by changing the “cone voltage” in
LC–MS.
When MS/MS is employed, the following can be selected for confirmatory purposes: (1) one precursor and two daughter ions; (2) two precursor ions, each with one
daughter. When third order MS (MS/MS/MS) is used, the confirmation can be done by
comparing one precursor, one daughter, and two granddaughter ions. Finally, in highresolution mass spectrometry, the resolution shall typically be greater than 10,000 for
the entire mass range at 10% valley and shall require three ions for confirmation.
References
1. Funk, W., Dammann, V., and Donnevert, G. (1995) Quality Assurance in Analytical Chemistry, VCH, Weinheim.
2. Günzler, H. (ed.) (1994) Accreditation and Quality Assurance in Analytical Chemistry,
Springer-Verlag, Berlin.
3. International Organisation for Standardisation. (1986) Quality Vocabulary (ISO/IEC Standard 8402), International Organisation for Standardisation, Geneva.
4. Inczedy, J., Lengyel, T., and Ure, A.M. (1997) Compendium of Analytical Nomenclature.
Definitive Rules, 3rd ed., Blackwell Science, Oxford, UK.
Internal Quality Criteria
229
5. Thompson, M., and Wood, R. (1995) Harmonized guidelines for internal quality control in
analytical chemistry laboratories (technical report). Pure Appl. Chem.67, 649-666.
6. Analytical Methods Committee. (1989) Principles of data quality control in chemical
analysis. Analyst 114, 1497–1503.
7. Huber, L. (1998) Validation of analytical methods: review and strategy. LC–GC Int. 11,
96–105.
8. Massart, D. L., Vandeginste, B. G. M., Buydens, L. M. C., de Jong, S., Lewi, P. J., and
Smeyers-Verbeke, J. (1997) Handbook of Chemometrics and Qualimetrics: Part A,
Elsevier, Amsterdam.
9. Swartz, M. and Krull, I. S. (1997) Analytical Method Development and Validation, Dekker,
New York.
10. Feinberg, M. (1996) La Validation des Méthodes D’analyse, Masson, Paris.
11. Green, J. M. (1996) A practical guide to analytical method validation. Anal. Chem. 68,
305A–309A.
12. Jenke, D. R. (1996) Chromatographic method validation: a review of current practices and
procedures. I. General concepts and guidelines. J. Liq. Chromatogr. Rel. Technol. 19,
719–736.
13. Jenke, D. R. (1996) Chromatographic method validation: a review of current practices and
procedures. II. Guidelines for primary validation parameters. J. Liq. Chromatogr. Rel.
Technol. 19, 737–757.
14. Jenke, D. R. (1996) Chromatographic method validation: a review of current practices and
procedures. III. Ruggedness, revalidation and system suitability. J. Liq. Chromatogr. Rel.
Technol. 19, 1873–1891.
15. http://www.eurachem.ul.pt/guides/CITAC%20EURACHEM%20GUIDE.pdf
16. S. Reynolds. Quality Control Procedures for Pesticide Residues Analysis. Guidelines for
Residues Monitoring in the European Union, 3rd ed., (2003) Document no. SANCO/
10476/2003. European Commission. York, United Kingdom.
17. Eurachem Guide: The Fitness for Purpose of Analytical Methods. A Laboratory Guide to
Method Validation and Related Topics, (1998). LGC, Teddington, United Kingdom. Also
available from the EURACHEM Secretariat and Web site. 18. Cuadros-Rodríguez, L.,
Hernández Torres, M. E., Almansa López, E., Egea González, F. J., Arrebola Liébanas, F.
J., and Martínez Vidal, J. L. (2002) Assessment of uncertainty in pesticide multiresidue
analytical methods: main sources and estimation. Anal. Chim. Acta 454, 297–214.
19. Thompson, M., Ellison, S.L.R., and Wood, R. (2002) Harmonized Guidelines for singlelaboratory validation of methods of analysis (IUPAC technical report). Pure Appl.
Chem.74, 835-855.
20. Williams, A., Ellison, S. L. R., and Roesslein, M. (Eds.). EURACHEM Guide, Quantifying
Uncertainty in Analytical Measurement, 2nd ed.,(2000) available at: http://
www.eurachem.ul.pt/guides/QUAM2000-1.pdf
21. International Organisation for Standardisation. (1993) Guide to the Expression of Uncertainty in Measurement, International Organisation for Standardisation, Geneva.
22. Martínez Vidal, J. L., Garrido Frenich, A., and Egea González, F. J. (2003) Internal quality control criteria for environmental monitoring of organic micro-contaminants in water.
Trends Anal. Chem. 22, 34–40.
23. Keith, L., Libby, R., Crummer, W., Taylor, J., Deegan, J., and Wentler, G., Jr. (1983)
Principles of environmental analysis. Anal. Chem. 55, 2210–2218.
24. Pérez-Bendito, D. and Rubio, S. (1999) Environmental Analytical Chemistry, Elsevier,
Amsterdam.
230
Garrido Frenich et al.
25. Quevauviller, P. (ed.). (1995) Quality Assurance in Environmental Monitoring—Sampling
and Sample Pre-treatment, VCH, Weinheim.
26. International Organisation for Standardisation. (1995) ISO Standards Handbook, Statistical Methods for Quality Control, Vol. 2 Measurement Methods and Results. Interpretation
of Statistical Data. Process Control, 4th ed., International Organisation for
Standardisation, Geneva.
27. Long, E. L. and Winefordner, J. D. (1983) Limit of detection: a closer look at the IUPAC
definition. Anal. Chem. 55, 712–724.
28. Miller, J. N. (1991) Basic statistical methods for analytical chemistry, Part 2: calibration
and regression methods, Analyst 116, 3–14.
29. Kellner, R., Mermett, M., Otto, M., Valcárcel, M., and Widmer, H. M. (eds.). (2004) Analytical Chemistry, 2nd ed., Wiley-VCH, Weinheim, chapter 6, p 69–89
30. Quevauviller, P. (2002). Quality Assurance for Water Analysis, Wiley/European Commission, Brussels.
31. Taylor, M. J., Hunter, K., Hunter, K., Lindsay, D., and Le Bouhellec, S. (2002) Multiresidue method for rapid screening and confirmation of pesticides in crude extracts of
fruits and vegetables using isocratic liquid chromatography with electrospray tandem mass
spectrometry. J. Chromatogr. A 982, 225–236.
32. Zrostlíkivá, J., Hajslová, J., Poustka, J., and Begany, P. (2002) Alternative calibration
approaches to compensate the effect of co-extracted matrix components in liquid chromatography–electrospray ionisation tandem mass spectrometry analysis of pesticide residues
in plant materials. J. Chromatogr. A 973, 13–26.
33. Egea González, F. J., Hernández Torres, M. E., Almansa López, E., Cuadros-Rodríguez,
L., and Martínez Vidal, J. L. (2002) Matriz effects of vegetable commodities in electróncapture detection applied to pesticide multiresidue analysis. J. Chromatogr. A 966, 155–165.
34. Martínez Vidal, J. L., Arrebola, F. J., Garrido Frenich, A., Martínez Fernández, J., and
Mateu-Sanchez, M. (2004) Validation of a gas chromatographic–tandem mass spectrometric method for analysis of pesticide residues in six food commodities. Selection of a
reference matrix for calibration. Chomatographia 59, 321—327.
35. Hernández Torres, M. E., Egea González, F. J., Cuadros-Rodríguez, L., Almansa López,
E., and Martínez Vidal, J. L. (2003) Assessment of matrix effects in gas chromatography
electron capture pesticide residue analysis. Chromatographia 57, 657–664.
36. http://www.iupac.org/symposia/conferences/method_validation_4nov99/report.html
Pesticide Analysis by ELISA
231
18
Immunoassay Methods for Measuring Atrazine
and 3,5,6-Trichloro-2-Pyridinol in Foods
Jeanette M. Van Emon and Jane C. Chuang
Summary
This chapter describes the use of enzyme-linked immunosorbent assay (ELISA) methods for the analysis of two potential environmental contaminants in food sample media:
atrazine and 3,5,6-trichloro-2-pyridinol (3,5,6-TCP). Two different immunoassay formats are employed: a magnetic particle immunoassay testing kit and a 96-microwell
plate immunoassay. Diluted, filtered, nonfat baby foods were analyzed directly by a commercial magnetic particle immunoassay testing kit for the determination of atrazine. Fatty
baby foods were extracted with water for the magnetic particle immunoassay analysis of
atrazine. For 3,5,6-TCP analysis, the food samples from a duplicate diet exposure study
were analyzed by a laboratory-based 96-microwell plate immunoassay. Acidic methanol
(72% methanol, 26% water, and 2% acetic acid) was the solvent for the food samples.
Key Words: Atrazine; baby food; duplicate-diet food; enzyme-linked immunosorbent assay (ELISA); magnetic particle immunoassay testing kit; 96-microwell plate immunoassay; 3,5,6-trichloro-2-pyridinol (3,5,6-TCP).
1. Introduction
Children can be exposed to pesticides by inhaling contaminated air, ingesting
tainted food as well as nondietary substances (i.e., dust or soil), or absorption through
the skin from contaminated media. With the passage of the U.S. Food Quality and
Protection Act of 1996 (1), new, more stringent standards for pesticide residues in
foods were established to provide increased emphasis on health protection for infants
and children. Pilot-scale field studies suggested that dietary ingestion was a major
route of exposure to some pollutants and that the doses received by children could
exceed those of adults living in the same household (2–5).
Determination of pesticides in food is often complicated by the presence of fats.
Samples typically require extensive cleanup steps before final analysis, greatly increasing analytical costs. Simple, rapid, cost-effective methods are also needed for
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
231
232
Van Emon and Chuang
environmental and biological media to determine aggregate pesticide exposures. Enzyme-linked immunosorbent assay (ELISA) methods are generally sensitive, specific,
and cost-effective. They can facilitate a high sample throughput and can be used as a
quantitative tool for monitoring pesticides in various matrices. Several ELISA methods have been developed for the detection of environmental pollutants in various
sample media (6–16). Performance data have been reported for real-world samples
using ELISA testing kits (12–16) and laboratory-based 96-microwell plate immunoassays (9,10). This chapter describes analytical methods utilizing two immunoassay
method formats (magnetic particle and 96-microwell plate immunoassays) for the
determination of atrazine in nonfatty and fatty baby foods and 3,5,6-TCP in composite
diet food samples.
2. Materials
The materials listed next are grouped by the two immunoassay method formats: (1)
magnetic particle immunoassay and (2) 96-microwell plate immunoassay. Within each
immunoassay format, materials are listed in two subsections: one for preparing samples
for immunoassay and one for performing the immunoassay.
2.1. Magnetic Particle Immunoassay for Atrazine in Baby Foods
2.1.1. Preparing Baby Food Samples
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
Vortex mixer.
Stainless steel spatulas.
Kim wipes.
Clean glass wool.
Silanized glass vials with Teflon-lined screw caps.
Distilled, deionized water.
Glass rods.
Pressurized solvent extraction system (ISCO SFX-200 or Dionex ASE 200 or equivalent).
Glass funnels.
Silanized glass wool.
Solid-phase extraction manifold and reservoir.
Graduated cylinders.
Disposable Pasteur glass pipets.
Sand (reagent grade).
Latex or nitrile gloves.
Methanol (distilled-in-glass or reagent grade).
Quartz fiber filters.
Acrodisc polytetrafluoroethylene (PTFE) 25-mm, 0.45-µm syringe filters.
Nitrogen evaporator.
Volumetric flasks.
Eppendorf pipets (or equivalent).
2.1.2. Magnetic Particle Immunoassay
1. Atrazine assay testing kit (e.g., Strategic Diagnostics, Newark, DE).
2. Magnetic separator rack (e.g., Strategic Diagnostics).
3. Atrazine diluent (e.g., Strategic Diagnostics).
Pesticide Analysis by ELISA
4.
5.
6.
7.
8.
9.
10.
11.
12.
233
Adjustable volume pipet.
RPA-1 RaPID analyzer (e.g., Strategic Diagnostics).
Vortex mixer.
Digital timer.
Kim wipes.
Pipet tips.
Waste container.
Latex or nitrile gloves.
Glass vials with Teflon-lined screw caps.
2.2. 96-Microwell Plate Immunoassay for 3,5,6-TCP in Duplicate-Diet Foods
2.2.1. Preparing Food Samples
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Vortex mixer.
Latex or nitrile gloves.
Methanol (distilled-in-glass or reagent grade).
Distilled, deionized water.
Centrifuge.
Nitrogen evaporator.
Volumetric flasks.
Eppendorf pipets (or equivalent).
Quartz fiber filters.
Acrodisc PTFE 25-mm, 0.45-µm syringe filters.
Glass funnels.
Graduated cylinders.
Glass vials with Teflon-lined screw caps.
2.2.2. 96-Microwell Plate Immunoassay
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
High-binding, flat-bottom 96-well microtiter plates (Nunc Maxsorb I or equivalent).
Plate washer (Skatron 300 or equivalent).
Calibrated, single-channel, adjustable-volume pipets (1000, 250, and 10 µL).
Calibrated, multichannel, adjustable-volume pipet (250 µL).
Serological pipets (5, 10, 25 mL).
Presterilized pipet tips (1000, 250, and 10 µL).
Microfuge tubes.
Glass scintillation vials.
Spectrophotometer (microplate reader).
Vortex mixer.
Digital timer.
Latex or nitrile gloves.
Distilled, deionized water.
Goat antirabbit immunoglobulin G alkaline phosphatase conjugate.
Microwell substrate system: 5X diethanolamine substrate solution and 5-mg p-nitrophenyl
phosphate tablets.
16. Phosphate-buffered saline with 0.05% Tween-20 and 0.02% sodium azide (PBST buffer)
at pH 7.4.
17. 3,5,6-TCP monoclonal antibody (17).
18. Coating antigen (17).
234
Van Emon and Chuang
3. Methods
The methods described include (1) magnetic particle immunoassay for atrazine in
baby foods and (2) 96-microwell plate immunoassay for 3,5,6-TCP in composite
duplicate-diet foods.
3.1. Magnetic Particle Immunoassay for Atrazine in Baby Foods
The method for the determination of atrazine in nonfatty baby foods consists of (1)
diluting the baby food with water and (2) analyzing the sample extract with the magnetic particle immunoassay testing kit. The method for the determination of atrazine in
fatty baby foods consists of (1) extracting the baby food with water, (2) mixing the
extract with sand, and (3) analyzing the sample extract with the magnetic particle
immunoassay.
3.1.1. Sample Preparation for Atrazine Magnetic Particle Immunoassay
1. For nonfatty food samples, dilute an aliquot (1 g) of baby food with 5 mL deionized or
reagent water. For the matrix-spiked sample, add a known amount of atrazine into the
food sample prior to the dilution process. Filter the diluted baby food through silanized
glass wool into a 60-mL reservoir attached to a solid-phase extraction manifold (see Note
1). The aqueous extract is now ready for the immunoassay. The immunoassay analysis
procedure used is described in Subheading 3.1.2.
2. For fatty food samples, remove an aliquot (nominal 4 g) of baby food after thoroughly
mixing the contents of the glass jar with a glass stirring rod. Mix the baby food with 4 g
sand. For the matrix-spiked sample, add a known amount of atrazine into the baby foodand-sand mixture. Transfer the mixture to an extraction cell (the baby food-and-sand mixture is sandwiched between two plugs of silanized glass wool and sand) for pressurized
liquid extraction. Deionized water is used as the extraction solvent. The instrumental
pressurized liquid extraction conditions are: (1) 2000-psi extraction pressure, (2) 150°C
extraction temperature, and (3) 20 min static and 20 min dynamic extraction times. The
resulting aqueous extract is then analyzed by the magnetic particle immunoassay for atrazine (see Note 2).
3.1.2. Atrazine Magnetic Particle Immunoassay Procedures
1. Carefully place 200-µL aliquots of the calibration solution (0, 0.1, 1.0, and 5.0 ng/mL),
control solution (3 ng/mL), sample extracts, and quality control samples (duplicates,
matrix spikes, and method blanks) into the bottom of individually labeled test tubes
secured onto a magnetic rack (see Note 3).
2. Add a 250-µL aliquot of the atrazine enzyme conjugate and a 500-µL aliquot of the atrazine antibody-coupled paramagnetic particles to the inside wall of each tube and allow to
flow down the side (see Note 4).
3. Mix the above solution on a vortex mixer and then incubate at room temperature
for 15 min.
4. Affix the magnetic separation rack to the magnetic base and let the samples sit for 2 min
to allow the magnetic particles to separate and adhere to the wall of the tube.
5. Invert the rack assembly over a waste container to decant the solution containing any
unbound reagents.
6. Blot the rim of each test tube on several layers of clean paper towels.
7. Add a 1-mL aliquot of the atrazine washing solution down the inside wall of each test
tube and allow the solution to stand for 2 min.
Pesticide Analysis by ELISA
235
8. Decant the solution into the waste container as before and blot the rim of each test tube on
paper towels. Repeat this washing step.
9. Remove the magnetic rack from the magnetic base.
10. Add a 500-µL aliquot of the color reagent down the inside wall of each tube and mix this
solution on the vortex mixer.
11. Allow the solution to incubate for 20 min at room temperature.
12. At the end of the incubation period, add a 500-µL aliquot of the stopping solution down
the wall of each tube to stop color development.
13. Analyze each test tube on the RPA-I RaPID photometric analyzer at 450 nm within 15
min of the addition of stopping solution (see Note 5).
3.2. 96-Microwell Plate Immunoassay for 3,5,6-TCP in Duplicate-Diet Food
The method for the determination of 3,5,6-TCP in food consists of (1) extracting
the food with acidic methanol (72% methanol, 26% water, and 2% acetic acid), (2)
diluting the sample extract with PBST, and (3) analyzing the sample extract with the
96-microwell plate immunoassay.
3.2.1. Sample Preparation Procedures for Duplicate-Diet Foods
Duplicate-diet sampling methodology has been used for determining exposures to
potential pesticide residues in food in the context of aggregated exposure measurements via dietary ingestion route (2,4,5,18–20). Duplicate-diet samples are the duplicate portions of each food and beverage that the study participants consumed.
Depending on study designs of the exposure field studies, composite duplicate-diet
solid food samples may represent the entire solid food intake of the study participants
over several days. Therefore, the composite duplicate-diet solid food samples are extremely complex in food composition, with mixtures of the four basic food groups
present in any sample.
1. Prior to the immunoassay, mix the composite solid food samples with dry ice in equal
proportions.
2. Homogenize the mixture with a commercial mechanical food processor.
3. Mix thoroughly individual aliquots of the food sample homogenates with Celite 545 and
sonicate with acidic methanol (72% methanol, 26% water, and 2% acetic acid) for 30 min.
4. Centrifuge the mixture at 1260g (2500 rpm) at 4°C for 20 min.
5. Remove a 200-µL aliquot of the supernatant, located beneath the fat layer, and dilute with
800 µL of PBST for subsequent ELISA analysis.
3.2.2. Procedures for 96-Microwell Plate Immunoassay
1. Perform the ELISA analyses for food samples using a laboratory-based 96-microwell
format (10,16).
2. Coat a 96-microwell plate with 100 µL of coating antigen (125 ng/mL) and incubate
overnight at 4°C.
3. Wash each plate three times with PBST in a plate washer programmed for a three-cycle
wash. Rotate the plates 180° between wash cycles to remove unbound antigens effectively.
4. Dry the plates further by tapping on absorbent paper, seal each plate with an acetate
cover, and store in a refrigerator until needed.
5. Prepare the calibration standard solutions in clean borosilicate vials by serial dilutions
with 10% methanol in PBST from a stock solution of 3,5,6-TCP to final concentrations of
25, 12.5, 6.25, 3.13, 1.56, 0.78, 0.39, 0.198, and 0.1 ng/mL.
236
Van Emon and Chuang
6. Also prepare a fresh aliquot of PBST solution containing none of the 3,5,6-TCP (designated as 0.0-ng/mL standard solution) for each assay.
7. Add individual 100-µL aliquots of the standard solutions, sample extracts, and blanks to
appropriate microwells in the antigen-coated plate.
8. Add a 100-µL aliquot of a 3,5,6-TCP monoclonal antibody (1:4000) in PBST to all
microwells except those used for instrument blanks.
9. Incubate the plates for 2 h at room temperature on an orbital shaker at low speed.
10. Remove the excess reagent, not bound to the plate, by washing with PBST as described above.
11. Dry the plate further by tapping on absorbent paper.
12. Add a 100-µL aliquot of goat antimouse immunoglobulin G alkaline phosphatase conjugate at a 1:1000 dilution in PBST to each microwell.
13. Incubate the plates again for 2 h at room temperature on the orbital shaker at low speed.
14. Remove the excess conjugate by washing with PBST and add 100 µL of para-nitrophenyl
phosphate at 1 ng/mL in diethanolamine buffer to each microwell.
15. After a 30-min room temperature incubation, read each microwell using a Molecular
Devices Spectra Max Plus microplate spectrophotometer (or equivalent).
16. Determine the absorbance of the microwells at 405 nm and normalize to a 1-cm path length.
17. Perform data processing with SOFTmaxPro software version 2.1.1 or equivalent interfaced to a personal computer using a four-parameter curve fit.
4. Notes
1. Quality control samples for each sample set should include a method blank, matrix spike,
and duplicate aliquots of samples. In a previous study (15), no atrazine was detected in
any of the nonspiked baby food samples. Quantitative recoveries of spiked baby foods
(pear, carrot, green bean, chicken noodle, broccoli/chicken/cheese) were achieved using
the methods described in Subheading 3.1. Overall method accuracy was 100 ± 20%, and
method precision was within ±20%.
2. If there are particles present in the extract, the sample extract should be filtered again
with an Acrodisc PTFE 25-mm, 0.45-µm syringe filter. The filtrate will then be ready for
the magnetic particle immunoassay. A solvent spike sample should also be prepared for
the Acrodisc filtration to assess any loss occurring during the filtration step.
3. It is important to warm the reagents to room temperature before conducting the magnetic
particle immunoassay. If the reagents are not at the proper temperature, the calibration
curve may not meet the specified requirements provided by the testing kit. It is also a
good practice to bring reagents to room temperature prior to measuring for the 96microwell plate immunoassay protocol.
4. The commercially available magnetic particle immunoassay testing kits typically have a
small dynamic optical density (od) range (i.e., 1.0–0.35 od) and small changes in od correlate to large changes in derived concentrations. Note that the differences between absorbance values from duplicate assays are generally small and are well within the
acceptance requirement (%CV < 10%) for the calibration standard solutions. However,
the percentage difference of the derived concentrations of the standard solution from duplicate assays sometimes exceeds 30%. The greater percentage difference values obtained
for some of the measured concentrations for the standards and samples may be caused by
a small volume of standard or sample retained in the pipet tip during the transfer step.
Extreme care should be taken when transferring each aliquot of standard or sample to the
test tube. A trace amount of aliquot not delivered to the test tube may result in a large
variation in the data from duplicate assays.
Pesticide Analysis by ELISA
237
5. For quantitative analysis, if the result of a sample extract is above the assay calibration
range (>5 ng/mL), the sample extract should be diluted accordingly with diluent and
reanalyzed by the magnetic particle immunoassay.
Acknowledgment
The US Environmental Protection Agency (EPA), through its Office of Research
and Development, funded and collaborated in the research described here under Contract 68-D-99-011 to Battelle. It has been subjected to agency review and approved for
publication. Mention of trade names or commercial products does not constitute
endorsement or recommendation by the EPA for use. We gratefully acknowledge J. J.
Manclus and A. Montoya, Laboratorio Integrado de Biogenieria, Universidad
Politecnica de Valencia, Spain, for the generous gift of TCP antibody and antigen.
References
1. Food Quality Protection Act of 1996. Available at: http://www.epa.gov/opppspsl/fqpa/
fqpa-iss.htm.
2. Wilson, N. K., Chuang, J. C., Lyu, C., and Morgan, M. K. (2003) Aggregate exposures of
nine preschool children to persistent organic pollutants at day care and at home. J. Expo.
Anal. Environ. Epidemiol. 13, 187–202.
3. MacIntosh, D. L., Kabiru, C., Echols, S. L., and Ryan, P. B. (2001) Dietary exposure to
chlorpyrifos and levels of 3,5,6-trichloro-2-pyridinol in urine. J. Expos. Anal. Environ.
Epidemiol. 11, 279–285.
4. Chuang, J. C., Callahan, P. J., Lyu, C. W., and Wilson, N. K. (1999) Polycyclic aromatic
hydrocarbon exposures of children in low-income families. J. Expo. Anal. Environ.
Epidemiol. 2, 85–98.
5. Chuang, J. C., Lyu, C., Chou, Y.-L., et al. (1998) Evaluation and Application of Methods
for Estimating Children’s Exposure to Persistent Organic Pollutants in Multiple Media,
EPA 600/R-98/164a, 164b, and 164c. US EPA, Research Triangle Park, NC.
6. Van Emon, J. M. and Lopez-Avila, V. (1992) Immunochemical methods for environmental analysis. Anal. Chem. 64, 79A–88A.
7. Van Emon, J. M., Brumley, W. C., and Reed, A. W. (2001) Elegant environmental immunoassays paper presented at the 221st ACS National Meeting, American Chemical Society, Division of Environmental Chemistry, April 1–5, 2001.
8. Lopez-Avila, V., Charan, C., and Van Emon, J. M. (1996) Quick determination of pesticides in foods by SFE-ELISA. Food Test. Anal. 2, 28–37.
9. Chuang, J. C., Miller, L. S., Davis, D. B., Peven, C. S., Johnson, J. C., and Van Emon, J.
M. (1998) Analysis of soil and dust samples for polychlorinated biphenyls by enzymelinked immunosorbent assay (ELISA). Anal. Chim. Acta 376, 67–75.
10. Van Emon, J. M., Reed, A. W, Chuang, J. C., Montoya, A., and Manclus, J. J. (2000)
Determination of 3,5,6-Trichloro-2-pyridinol (TCP) by ELISA. Paper presented at Immunochemistry Summit 7, 219th National ACS Meeting, San Francisco, CA, March 26–31.
11. Lucas, A. D., Goodrow, M. H., Seiber J. N., and Hammock, B. D., (1995) Development of
an ELISA for the N-dealkylated s-triazines: application to environmental and biological
samples. Food Agric. Immunol. 7, 227–241.
12. Mackenzie, B. A., Striley, C. A. F., Biagini, R. E., Stettler, L. E., and Hines, C. J. (2001)
Improved rapid analytical method for the urinary determination of 3,5,6-trichloro-2pyridinol, a metabolite of chlorpyrifos. Bull. Environ. Contam. Toxicol. 65, 1–7.
238
Van Emon and Chuang
13. Shackelford, D. D., Young, D. L., Mihaliak, C. A., Shurdut, B., A., and Itak, J. A. (1999)
Practical immunochemical method for determination of 3,5,6-trichloro-2-pyridinol in
human urine: applications and considerations for exposure assessment. J. Agric. Food
Chem. 47, 177–182.
14. Chuang, J. C., Pollard, M. A., Chou, Y.-L., and Menton, R. G. (1998) Evaluation of
enzyme-linked immunosorbent assay for the determination of polycyclic aromatic hydrocarbons in house dust and residential soil. Sci. Total Environ. 224, 189‚ 199.
15. Chuang, J. C., Pollard, M. A., Misita, M., and Van Emon, J. M. (1999) Evaluation of analytical methods for determining pesticides in baby food. Anal. Chim. Acta 399, 135–142.
16. Chuang, J. C., Van Emon, J. M., Reed, A. W., and Junod, N. (2004) Comparison of immunoassay and gas chromatography/mass spectrometry methods for measuring 3,5,6trichloro-2-pyridinol in multiple sample media. Anal. Chim. Acta 517, 177–185.
17. Manclús, J. J. and Montoya, A. (1996) Development of an enzyme-linked immunosorbent
assay for 3,5,6-trichloro-2-pyridinol. 1. Production and characterization of monoclonal
antibodies. J. Agric. Food Chem. 44, 3703–3709.
18. Wilson, N. K., Chuang, J. C., Iachan, R., et al. (2004) Design and sampling methodology
for a large study of preschool children’s aggregate exposures to persistent organic pollutants in their everyday environments. J. Expo. Anal. Environ. Epidemiol. 14, 260–274.
19. Thomas, K., Sheldon, L. S., Pellizzari, E., Handy, R., Roberts, J., and Berry, M. (1997)
Testing duplicate diet sample collection methods for measuring personal dietary exposures to chemical contaminants. J. Expo. Anal. Environ. Epidemiol. 7, 17–36.
20. Scanlon, K., Macintosh, D., Hammerstrorm, K., and Ryam, P. (1999) A longitudinal investigation of solid-food based dietary exposure to selected elements. J. Expo. Anal.
Environ. Epidemiol. 9, 485–493.
QuEChERS Approach for Pesticides
239
19
Quick, Easy, Cheap, Effective, Rugged, and Safe Approach
for Determining Pesticide Residues
Steven J. Lehotay
Summary
This chapter describes a simple, fast, and inexpensive method for the determination
of pesticides in foods and potentially other matrices. The method, known as the quick,
easy, cheap, effective, rugged, and safe (QuEChERS) method for pesticide residues involves the extraction of the sample with acetonitrile (MeCN) containing 1% acetic acid
(HAc) and simultaneous liquid–liquid partitioning formed by adding anhydrous magnesium sulfate (MgSO4) plus sodium acetate (NaAc), followed by a simple cleanup step
known as dispersive solid-phase extraction (dispersive-SPE). The QuEChERS method is
carried out by shaking a fluoroethylenepropylene (FEP) centrifuge tube that contains 1
mL 1% HAc in MeCN plus 0.4 g anhydrous MgSO4 and 0.1 g anhydrous NaAc per gram
wet sample. The tube is then centrifuged, and a portion of the extract is transferred to a
tube containing 50 mg primary secondary amine (PSA) and 50 mg C18 sorbents plus 150
mg anhydrous MgSO4 per milliliter extract (the dispersive-SPE cleanup step). Then, the
extract is centrifuged and transferred to autosampler vials for concurrent analysis by gas
chromatography–mass spectrometry (GC–MS) and liquid chromatography–tandem mass
spectrometry (LC–MS/MS). Different options in the protocol are possible depending on
alternate analytical instrumentation available, desired limit of quantitation (LOQ), scope
of targeted pesticides, and matrices tested.
Key Words: Food; fruits; gas chromatography; liquid chromatography; mass spectrometry; pesticide residue analysis; sample preparation; vegetables.
1. Introduction
Multiresidue analysis of pesticides in fruits, vegetables, and other foods is a primary function of many regulatory, industrial, and contract laboratories throughout the
world. It is estimated that more than 200,000 food samples are analyzed worldwide
each year for pesticide residues to meet a variety of purposes. Once analytical quality
requirements (trueness, precision, sensitivity, selectivity, and analytical scope) have
been met to suit the need for any particular analysis, all purposes for analysis favor
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
239
240
Lehotay
practical benefits (high sample throughput, ruggedness, ease of use, low cost and labor, minimal solvent usage and waste generation, occupational and environmental
friendliness, small space requirements, and few material and glassware needs).
A number of analytical methods designed to determine multiple pesticide residues
have been developed in the time since this type of analysis became important (1–10).
However, few if any of these methods can simultaneously achieve high-quality results
for a wide range of pesticides and the practical benefits desired by all laboratories. In
2003, the QuEChERS (quick, easy, cheap, effective, rugged, and safe) method for
pesticide residue analysis was introduced (11); it provides high-quality results in a
fast, easy, inexpensive approach. Follow-up studies have further validated the method
for more than 200 pesticides (12), improved results for the remaining few problematic
analytes (13), and tested it in fat-containing matrices (14).
The QuEChERS method has several advantages over most traditional methods of
analysis in the following ways: (1) high recoveries (>85%) are achieved for a wide
polarity and volatility range of pesticides, including notoriously difficult analytes; (2)
very accurate (true and precise) results are achieved because an internal standard
(ISTD) is used to correct for commodity-to-commodity water content differences and
volume fluctuations; (3) high sample throughput of about 10–20 preweighed samples
in about 30–40 min is possible; (4) solvent usage and waste are very small, and no
chlorinated solvents are used; (5) a single person can perform the method without
much training or technical skill; (6) very little labware is used; (7) the method is quite
rugged because extract cleanup is done to remove organic acids; (8) very little bench
space is needed, thus the method can be done in a small mobile laboratory if needed;
(9) the acetonitrile (MeCN) is added by dispenser to an unbreakable vessel that is
immediately sealed, thus minimizing solvent exposure to the worker; (10) the reagent
costs in the method are very inexpensive; and (11) few devices are needed to carry out
sample preparation.
This chapter provides the protocol for the QuEChERS method that is currently undergoing an extensive interlaboratory trial for evaluation and validation by pesticidemonitoring programs in several countries. In brief, the method uses a single-step
buffered MeCN extraction while salting out water from the sample using anhydrous
magnesium sulfate (MgSO4) to induce liquid–liquid partitioning. For cleanup, a
simple, inexpensive, and rapid technique called dispersive solid-phase extraction (dispersive-SPE) is conducted using a combination of primary secondary amine (PSA)
and C18 sorbents to remove fatty acids among other components and anhydrous
MgSO4 to reduce the remaining water in the extract. Then, the extracts are concurrently analyzed by liquid chromatography (LC) and gas chromatography (GC) combined with mass spectrometry (MS) to determine a wide range of pesticide residues.
The final extract concentration of the method in MeCN is 1 g/mL. To achieve <10ng/g limit of quantitation (LOQ) in modern GC–MS, a large volume injection (LVI) of
8 µL is typically needed, or the final extract can be concentrated and solvent exchanged
to toluene (4 g/mL), in which case 2-µL splitless injection provides the anticipated
degree of sensitivity. If MS instruments are not available in the laboratory, other options are also possible to analyze the samples using LC and GC coupled to element-selective detectors. These aspects are discussed in more detail in Subheadings 1.2., 1.3., and 3.
QuEChERS Approach for Pesticides
241
Table 1 lists the many pesticides that have been successfully evaluated with the
QuEChERS method. Many other untested pesticides in the same classes can be analyzed by the method, and the final choice of analytes for this protocol depends on the
analyst’s particular needs. The only pesticides that have failed to be validated successfully in studies thus far include asulam, daminozide, dicofol, captan, folpet, pyridate,
and thiram. The method does not work for carboxylic acids, such as daminozide, because of their strong retention on PSA during the cleanup step: dicofol degrades rapidly to dichlorobenzophenone in samples, which is why it was not found in the extracts;
asulam, pyridate, and thiram are exceptionally difficult and are not currently analyzed
in multiclass, multiresidue methods; and the problems with captan and folpet are not
likely to be because of the QuEChERS sample preparation method, but related to their
GC–MS analysis, which is especially difficult because of their degradation on active
sites in the GC system. (Unfortunately, these pesticides cannot be readily analyzed by
LC–tandem mass spectrometry [MS/MS] either.)
1.1. Calibration in Pesticide Methods
In any quantitative method, the accuracy of the result cannot be better than the
accuracy of the calibration. Pesticide residue analysis using chromatographic methods
nearly always utilizes external calibration, in which analyte solutions of known concentrations are injected contemporaneously (in the same sequence) as the sample extracts, and the intensity of the analyte peaks in the standards is compared with those
from the samples to determine the pesticide concentrations. The number of calibration
standards needed in the determination and their concentrations depend on the quality
assurance (QA) requirements for the analysis or laboratory, but generally four calibration standards (plus the matrix blank, or zero standard) dispersed from the LOQ to the
highest expected analyte concentration are accepted practice (15,16). Reported results
should not list concentrations outside the concentration range covered by the calibration standards.
Furthermore, QA guidelines generally dictate that analytical methods be evaluated
to determine the effects of matrix components in the extracts on the quantitative results (15,16). If it is demonstrated that no differences are observed between analyte
peak intensities in matrix extracts vs those in solvent only over the entire concentration range, then calibration standards may be prepared in solvent-only solutions. Each
pesticide–matrix pair must be evaluated in this case, which can be a great deal of work.
Otherwise, the matrix effects must be overcome empirically because the determined
results may not be altered with a “fudge factor” in most pesticide analysis applications.
In general, GC methods for organochlorine insecticides are not affected by matrix,
and LC using non-MS detection techniques dos not encounter matrix effects (unless
there are chemical interferences in the signals). However, LC–MS techniques, particularly using electrospray ionization (ESI), are susceptible to ion suppression effects
from coeluting components in the chromatogram, even though direct interference in
the MS spectrum is seldom observed (17). This indirect matrix effect in LC–MS tends
to yield falsely low results in the samples when compared to standards that do not
contain matrix components. In the case of GC, matrix components tend to fill active
sites in the system (mainly in the injector liner and capillary column). This reduces the
242
Lehotay
Table 1
Possible Pesticide Analytes That Have Been Shown to Yield >90% Recoveries Using
the QuEChERS Method
acephate,a acetamiprid, Acrinathrin, aldicarb, aldicarb sulfone, aldicarb sulfoxide, Aldrin,
azaconazole, azamethiphos, azinphos-methyl, azoxystrobin, Bifenthrin, bitertanol,
Bromopropylate, bromuconazole, Bupirimate, buprofezin, butocarboxim, butocarboxim sulfone, butocarboxim sulfoxide, Cadusafos, carbaryl, carbendazim, carbofuran, 3-hydroxycarbofuran, chlorbromuron, (α-, γ-)Chlordane, (α-, β-)Chlorfenvinphos, Chlorpropham,
Chlorpyrifos, Chlorpyrifos-methyl, Chlorthaldimethyl, Chlorothalonil, a Chlozolinate,
clofentezine, Coumaphos, cycloxydim, a (λ-)Cyhalothrin, cymoxanil, Cypermethrin,
cyproconazole, cyprodinil, (2,4′-, 4,4′-)DDE, (2,4′-, 4,4′-)DDT, Deltamethrin, demeton,
demeton-O-sulfoxide, demeton-S-methyl, demeton-S-methyl sulfone, desmedipham, Diazinon,
dichlofluanid,a Dichlorobenzophenone, dichlorvos, diclobutrazole, Dicloran, dicrotophos, Dieldrin, Diethofencarb, difenoconazole, Diflufenican, dimethoate, dimethomorph, diniconazole,
Diphenyl, Diphenylamine, disulfoton, disulfoton sulfone, diuron, dmsa, dmst, dodemorph, (α-,
β-)Endosulfan, Endosulfan sulfate, EPN, epoxiconazole, Esfenvalerate, etaconazole,
ethiofencarb sulfone, ethiofencarb sulfoxide, Ethion, ethirimol, Ethoprophos, etofenprox,
Etridiazole, Famoxadone, fenamiphos, fenamiphos sulfone, Fenarimol, Fenazaquin,
fenbuconazole, fenhexamid, a Fenithrothion, fenoxycarb, Fenpiclonil, Fenpropathrin,
Fenpropidine, fenpropimorph, fenpyroximate, Fenthion, fenthion sulfoxide, Fenvalerate,
florasulam,a Flucythrinate I and II, Fludioxonil, flufenacet, Flufenconazole, flusilazole,
Flutolanil, Fluvalinate, Fonophos, fosthiazate, Furalaxyl, furathiocarb, furmecyclox, Heptachlor, Heptachlor epoxide, Heptenophos, Hexachlorobenzene, hexaconazole, hexythiazox,
imazalil, imidacloprid, Iprodione, iprovalicarb, isoprothiolane, isoxathion, kresoxim-methyl,
Lindane, linuron, Malathion, malathion oxon, Mecarbam, mephosfolan, Mepronil, Metalaxyl,
metconazole, methamidophos,a Methidathion, methiocarb, methiocarb sulfone,a methiocarb
sulfoxide, methomyl, methomyl-oxime, metobromuron, metoxuron, Mepanipyrim, Mevinphos,
monocrotophos, monolinuron, myclobutanil, nuarimol, Ofurace, omethoate, oxadixyl, oxamyl,
oxamyl-oxime, oxydemeton-methyl, paclobutrazole, Parathion, Parathion-methyl,
penconazole, pencycuron, (cis-, trans-)Permethrin, phenmedipham, o-Phenylphenol, Phorate,
phorate sulfone, Phosalone, Phosmet, Phosmet-oxon, phosphamidon, Phthalimide,
picoxystrobin, Piperonyl butoxide, pirimicarb, pirimicarb-desmethyl, Pirimiphos-methyl,
prochloraz, Procymidone, profenofos, Prometryn, Propargite, Propham, propiconazole,
propoxur, Propyzamide, Prothiofos, pymetrozine,a Pyrazophos, pyridaben, pyridaphenthion,
pyrifenox, pyrimethanil, Pyriproxyfen, Quinalphos, Quinoxyfen, Quintozene, sethoxydim,a
spinosad, spiroxamine, tebuconazole, tebufenozide, Tebufenpyrad, tetraconazole, Tetradifon,
Tetrahydrophthalimide, Terbufos, Terbufos sulfone, thiabendazole, thiacloprid, thiamethoxam,
thiodicarb, thiofanox, thiofanox sulfone, thiofanox sulfoxide, thiometon, thiometon sulfone,
thiometon sulfoxide, thiophanate-methyl, Tolclofos-methyl, tolylfluanid, a triadimefon,
triadimenol, Triazophos, trichlorfon, tricyclazole, tridemorph, trifloxystrobin, trifluminazole,
Trifluralin, Triphenylphosphate, vamidothion, vamidothion sulfone, vamidothion sulfoxide,
Vinclozolin
GC-amenable pesticides are capitalized; those preferentially analyzed by LC–MS/MS are not capitalized; those that can be analyzed by either technique are underlined.
aOr
>70%.
QuEChERS Approach for Pesticides
243
number of active sites exposed to those analytes that also tend to adsorb on the sites.
Therefore, the common effect of matrix in GC is to cause greater response of the
susceptible analytes in the sample extracts than in solvent only because more of the
analytes are lost to active sites in calibration standards in solvent-only solutions (18–
25). Those pesticides most strongly affected in GC tend to contain hydroxy, amino,
phosphate, and other relatively polar groups (21).
Several approaches have been devised in an attempt to overcome matrix effects in
LC–MS (26–28) and GC (11,19–25), but in both instrumental methods, the most common approach is the use of matrix-matched calibration standards (20–23). Matrix
matching has been shown to work better than most other approaches, but it is not ideal
because it requires many blank matrices (which may be hard to find), entails extra
extractions, and reduces ruggedness by introducing more matrix to the analytical instrument in a sequence than would be injected otherwise.
In the future, enough evidence may accumulate for two promising approaches to
replace matrix-matching calibration: (1) the echo technique in LC–MS and (2) analyte
protectants in GC. The echo technique involves injection of a calibration standard in
solvent only just prior to (or immediately after) the sample extract when the mobile
phase gradient has just started. This leads to two peaks adjacent to each other per
analyte; one is the standard, and the other is from the sample. If ion suppression effects
are the same for both peaks, then this will lead to accurate results (26–28). In GC, the
use of analyte protectants takes advantage of the increased response provided by the
matrix-induced enhancement effect to equalize the signals of susceptible analytes in
sample extracts and calibration standards alike (11,19,24,25). This is done by adding a
high concentration of components (analyte protectants) with multiple hydroxy groups
to sample extracts and calibration standards in solvent. The analyte protectants have
been shown to work well in providing accurate results, better peak shapes, and lower
LOQ, and they surprisingly increase ruggedness of the analysis by continuing to work
even in a very dirty GC system (11,24,25).
Although the two alternate approaches may become the standard methods in the
near future, it is too early to make this assertion now. Also, the careful choice of
analytes quantified by LC–MS/MS and GC–MS may bypass matrix effects altogether.
In the meantime, instructions in this protocol (see Subheading 3.3.) are given for the
use of four matrix-matched calibration standards (plus the zero standard) to cover the
concentration range of the pesticides that need to be detected in the samples.
1.2. Analysis of GC-Amenable Pesticide Residues
Traditionally, selective detectors in GC have been used to detect individual classes
of GC-amenable pesticides, such as organochlorines, organophosphates, and
organonitrogens (1–6). Either multiple injections were necessary or split flows would
be made to multiple detectors. GC–MS has become the primary approach to analyze
all classes of GC-amenable pesticides in the same chromatogram (7–10). Traditionally, GC–MS was mainly used for confirmation of analytes previously detected by
selective detectors, but modern GC–MS instruments are sensitive, easy to use, reli-
244
Lehotay
able, and affordable for most laboratories. GC–MS has become a standard laboratory
instrument and can provide qualitative and quantitative information for essentially
any GC-amenable analyte in a single injection. Especially when fitted with LVI, GC–
MS can provide comparable sensitivity of selective detectors even in complicated extracts.
Several MS techniques are available, the most common of which use a quadrupole
design that is very rugged and practical. Ion trap MS instruments provide the advantages of lower LOQ in full-scan operation and the option for conducting MSn of targeted analytes. Time-of-flight (TOF) instruments are more expensive, but may provide
greater speed or higher mass resolution in the analysis. Magnetic sector is a fourth MS
instrument option, but they are very large and expensive and generally reserved for
special applications. Any of these MS techniques may be coupled with GC for pesticide residue analysis and should produce equal high-quality results (26,27). Any difference in analytical accuracy between these types of MS systems is most likely a
function of the injection process and not related to detection (10).
Each MS approach also has multiple modes of operation. The most common ionization approach for GC–MS analysis of pesticides is electron impact (EI) ionization,
which often yields many mass fragments to aid analyte identification. EI at 70 eV is
the standard used for generating spectra with commercial instruments, and mass spectral libraries are available that contain full-scan spectra for as many as 300,000 compounds at these conditions. Another facet in MS analysis involves whether selected
ion monitoring (SIM) or MSn should be employed to provide lower LOQ and greater
selectivity in the analysis of targeted pesticides (8,9), or whether full-scan MS should
be conducted to potentially identify any GC-amenable chemical in the chromatogram
(7). The targeted approach limits the number of analytes to about 60 that can be
detected in a typical 30- to 40-min GC chromatogram, but full-scan operation permits
a nearly unlimited number of analytes in a single injection. The analyst should refer to
the literature if needed for further discussion (29–31).
1.3. Analysis of LC-Type Pesticide Residues
Since the development of robust atmospheric pressure ionization (API) ion source
designs, which consist of ESI and atmospheric pressure chemical ionization (APCI),
very powerful and reliable LC–MS instruments have been introduced commercially.
Depending on the source design, APCI works equally well or better as ESI for many
pesticides, but APCI heats the analytes more than ESI, which potentially leads to problems for thermolabile pesticides. Thus, ESI has greater analytical scope and has
become the primary ionization technique in LC–MS, but if all of the analytes in a
method are compatible with APCI, then APCI may provide benefits of fewer ion suppression effects and a higher flow rate.
Because of the soft ionization nature of API, high background of LC mobile phases,
and relatively low separation efficiency of LC, tandem MS (or high resolution) is
often required to determine pesticide residues in complex extracts. Just as quadrupole,
ion trap, TOF, and magnetic sector instruments may be coupled to GC, they may also
be used in LC with the same advantages and disadvantages (30). Moreover, just as
trueness and precision in the analytical result are generally influenced by injection in
QuEChERS Approach for Pesticides
245
GC–MS more than detection, the performance of the ion source is typically the limiting factor in LC–MS techniques.
LC–MS/MS is rapidly becoming an indispensible analytical tool in analytical chemistry, and most pesticide-monitoring laboratories in developed countries have access
to LC–MS/MS instruments. Many modern pesticides are not GC amenable, and if they
do not fluoresce or contain a strong chromophore for ultraviolet/visible absorption,
then LC–MS/MS is the only way to detect the chemical in its underivatized form.
Derivatization of these types of analytes followed by GC analysis was often done in
the past, but such methods are usually problematic to develop and implement in practice, and they do not lend themselves to multiclass, multiresidue applications (1,7).
Despite the great capital expense of the instruments, the powerful attributes of LC–
MS/MS provide exceptional analytical performance, save time in method development, and can be used robustly in a variety of routine or special projects
(12,17,26–28,32).
The quality of LC–MS/MS analyses and instruments has reached the point that
LC–MS/MS provides superior results than GC–MS even for many GC-amenable pesticides. This is indicated in Table 1; 90% of the underlined pesticides are not capitalized, which means that LC–MS/MS provided better sensitivity, greater trueness, or
more precision than GC–MS for that pesticide (12). The broad peaks in LC separations allow plenty of time in the MS/MS data collection process to monitor many other
coeluting peaks without affecting quality of the results. Thus, hundreds of pesticide
analytes can be monitored by LC–MS/MS in a single chromatogram (12,26–28), which
is not possible in GC–MS using SIM or MSn techniques. Alternate methods for LC
analysis using selective detectors rely on the LC separation to resolve the difference
analytes from each other and matrix interferences. This is acceptable in a few
multiresidue applications, such as N-methyl carbamate insecticides (1,6–8), but traditional LC methods cannot meet multiclass, multiresidue analytical needs.
Indeed, the concurrent use of LC–MS/MS and (LVI) GC–MS for nearly any pesticide constitutes the state-of-the-art approach to multiclass, multiresidue analysis of
pesticides in a variety of matrices. The QuEChERS method is an effective sample
preparation procedure that very efficiently produces sample extracts suitable for both
of these powerful analytical tools. This approach can be improved further in the near
future by integrating other advanced techniques, such as direct sample introduction
(33–35) and fast-GC–MS separations (30,36–38), which may someday become the
ultimate approach to pesticide residue analysis. The following protocol is an important step to meeting that challenge.
2. Materials
2.1. Sample Comminution
1.
2.
3.
4.
5.
6.
Food chopper (e.g., Stephan or Robotcoupe vertical cutters).
Probe blender (e.g., Ultraturrax) or Polytron homogenizers.
Container jars.
Blank sample verified to contain no detectable analytes.
Samples to be analyzed.
Freezer.
246
Lehotay
Optional items are:
1. Dry ice or liquid nitrogen.
2. Cryogenic chopper.
2.2. QuEChERS Sample Preparation
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
Analytical-grade MeCN.
High-performance liquid chromatographic (HPLC)-grade glacial acetic acid (HAc).
1% HAc in MeCN (v/v) (e.g., 10 mL glacial HAc in 1 L MeCN solution).
Reagent-grade anhydrous sodium acetate (NaAc) (see Note 1).
Powder form anhydrous MgSO4 > 98% pure (see Note 2).
PSA sorbent with 40-µm particle size (e.g., Varian, Harbor City, CA) (see Note 3).
Analytical-grade toluene.
Pesticide reference standards, typically above 99% purity (e.g., Chemservice,
Accustandard, Dr. Ehrenstorfer).
Pesticide stock solutions (10 mg/mL): add 5 mL toluene to each 50 mg pesticide reference standard in 8-mL dark glass vials with Teflon-lined caps and store at 20°C or below
(see Note 4).
ISTD stock solution (2 mg/mL): add 5 mL toluene to 10 mg d10-parathion (e.g., C/D/N
Isotopes or Cambridge Isotope Laboratories) in 8-mL dark glass vial with Teflon-lined
cap and store at 20°C or below (see Note 5).
Triphenylphosphate (TPP) stock solution (2 mg/mL): add 5 mL toluene to 10 mg TPP in
8-mL dark glass vial with Teflon-lined cap and store at 20°C or below.
Working standard pesticides solution (40 ng/µL): add 400 µL of each pesticide stock
solution at room temperature (RT) to a 100-mL volumetric flask containing 10 mL 1%
HAc in MeCN and dilute with MeCN to the mark. Transfer four roughly equal portions of
the solution to 40-mL dark glass vials with Teflon-lined caps and store at 20°C or below
(see Note 6).
ISTD working solution (20 ng/µL): add 250 µL of the ISTD stock solution at RT to a 25mL volumetric flask and dilute with MeCN to the mark. Transfer the solution to a 40-mL
dark glass vial with Teflon-lined cap and store at 20°C or below.
TPP working solution (2 ng/µL): add 25 µL of the TPP stock solution at RT to a 25-mL
volumetric flask and dilute with 1% HAc in MeCN to the mark. Transfer the solution to a
40-mL dark glass vial with Teflon-lined cap and store at 20°C or below (see Note 7).
Calibration standard spiking solutions w, x, y, and z (for w, x, y, and z standards): add 50
µL of ISTD stock solution, 2.5 mL of 1% HAc in MeCN solution, and 12.5•(w, x, y, and
z) µL of the 40-ng/µL working standard pesticides solution at RT per (w, x, y, and z) ng/
g desired equivalent calibration standard concentration into a 25-mL volumetric flask and
fill to the mark with MeCN. For example, if the w standard is to be 10 ng/g, then add 125
µL of the 40-ng/µL working standard pesticides solution to the flask. Transfer the solutions to four 8-mL dark glass vials with Teflon-lined caps and store at 20°C or below.
50-mL Fluoroethylenepropylene (FEP) centrifuge tubes (e.g., Nalgene 3114-0050 or
equivalent) (or 250-mL FEP centrifuge bottles for 16- to 75-g samples).
Top-loading balance.
Solvent dispenser (15 mL for 15-g sample) and 1- to 4-L bottle.
Centrifuges.
Vials containing anhydrous NaAc plus anhydrous MgSO4: add 1.5 g anhydrous NaAc
plus 6 g anhydrous MgSO4 to each vial for use with 15-g sample size (see Note 8).
QuEChERS Approach for Pesticides
247
21. Sealable centrifuge tubes (2–15 mL) containing powders for dispersive SPE: add 50 mg
PSA sorbent plus 150 mg anhydrous MgSO4 per 1 mL of extract to undergo cleanup (see
Note 8).
Optional items:
1.
2.
3.
4.
5.
6.
7.
8.
Mechanical shaker, probe blender, or sonication device.
C18 sorbent with 40-µm particle size (see Note 9).
Graphitized carbon black (GCB; e.g., Supelco or Restek) (see Note 10).
Vortex mixer.
Minicentrifuge.
Evaporator (e.g., Turbovap or N-Evap).
Graduated centrifuge tubes (10–15 mL) for use in evaporator.
Calibration standard spiking solutions w, x, y, and z in toluene (for w, x, y, and z standards): add 50 µL of ISTD stock solution and 12.5•(w, x, y, and z) µL of the 40-ng/µL
working standard pesticides solution at RT per (w, x, y, and z) ng/g desired equivalent
calibration standard concentration into a 25-mL volumetric flask and fill to the mark with
toluene. For example, if the w standard is to be 10 ng/g, then add 125 µL of the 40-ng/µL
working standard pesticides solution to the flask. Transfer the solutions to four 8-mL
dark glass vials with Teflon-lined caps and store at 20°C or below.
2.3. Analysis of GC-Amenable Pesticides
1.
2.
3.
4.
GC–MS system.
Programmable temperature vaporizer for LVI.
Autosampler.
A 30-m analytical capillary column with 0.25 mm id, 0.25 µm of (5% phenyl)methylpolysiloxane low-bleed stationary phase (e.g., DB-5ms or equivalent).
5. Retention gap such as a 1- to 5-m, 0.25 mm id deactivated capillary column.
6. Helium at 99.999% purity.
Alternatives:
1. GC system(s) coupled with selective detector(s) such as pulsed flame photometric detector, flame photometric detector, halogen-specific detector, electron capture detector, electrolytic conductivity detector, atomic emission detector, nitrogen–phosphorus detector.
2. Split/splitless injector.
2.4. Analysis of LC-Type Pesticides
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
LC–MS/MS system.
ESI ion source.
Automated divert valve placed between analytical column and ion source.
Syringe pump for direct infusion of solutions into ion source.
Autosampler.
HPLC-grade methanol (MeOH).
HPLC-grade water.
Double-distilled, 88% formic acid.
5 mM Formic acid in MeOH: add 214 µL formic acid to MeOH in 1 L solution.
5 mM Formic acid in water: add 214 µL formic acid to water in 1 L solution.
6.7 mM Formic acid in water: add 72 µL formic acid to water in 250 mL solution.
15 cm long, 3.0 mm id, 3-µm particle size C18 analytical column.
4 cm long, 3.0 mm id C18 guard column.
248
Lehotay
Fig. 1. Outline of the protocol in the QuEChERS method.
Alternatives:
1. LC system(s) coupled with selective detector(s) (e.g., fluorescence, diode array detector,
ultraviolet/visible absorbance).
2. Postcolumn derivatization system and reagents.
3. Methods
Figure 1 shows a flowchart of the overall protocol of the approach, including the
QuEChERS sample preparation method and its two main options that essentially depend on the desired LOQ in GC–MS. Option A relies on LVI to achieve the low LOQ
if needed, and Option B entails solvent evaporation and exchange to toluene to increase the amount of equivalent sample injected in splitless mode. Once all the mate-
QuEChERS Approach for Pesticides
249
rials are ready and the 15-g homogenized subsamples have been weighed into the 50mL tubes, a single analyst can prepare 10–20 extracts with the QuEChERS method in
approx 30–40 min in Option A. The solvent exchange and evaporation step in Option
B approximately doubles the time needed for the analyst to complete the method.
3.1. Sample Comminution
For food samples, an appropriate chopper (e.g., vertical cutter) must be used to
comminute large, representative sample portions up to 9 kg (1). Blend the sample until
it gives a consistent texture. Transfer approx 200 g to a sealable container for freezer
storage after further comminution with a probe blender. Blend the subsample with the
mixer until it is homogeneous. A second subsample (e.g., 15 g) is taken for extraction
immediately, and the container is then sealed and stored in the freezer in case reanalysis is necessary (see Notes 11 and 12).
3.2. QuEChERS Sample Preparation
The QuEChERS method may be scaled appropriately to any subsample size shown
to be adequately representative of the original sample. If LVI is not used for GC–MS,
then 12 g or more must be extracted to typically detect <10 ng/g of the pesticides in
food. The method is designed for samples with >75% moisture. If needed, add water
to hydrate drier samples so that moisture becomes approx 80% and pores in the sample
are more accessible to the extraction solvent. The following instructions are scaled for
15-g samples (after hydration, if needed) extracted in 50-mL FEP centrifuge tubes.
Safety note: Work with pesticides and solvents in a hood and wear appropriate laboratory safety glasses, coat, and gloves; ensure that the centrifuge is balanced and do not
exceed the safety limits of the tubes or rotors used.
3.2.1. Extraction and Cleanup
1. Weigh 15 g sample into each tube (use 13 mL water for a reagent blank).
2. Weigh 15 g blank(s) to attain enough extract for five matrix-matched calibration standards as described in Subheadings 3.2.2. and 3.2.3. Add 75 µL working standard pesticides solution to an additional matrix blank (this will yield 200 ng/g) as a quality control
(QC) spike for evaluating recoveries.
3. Add 15 mL 1% HAc in MeCN into each tube using the solvent dispenser.
4. Add 150 µL of ISTD solution (this will yield 200 ng/g) to samples, reagent blank, and QC
spike, but not to blank(s) used for matrix-matched calibration standards (see Note 13).
5. Add 6 g anhydrous MgSO4 plus 1.5 g anhydrous NaAc (or 2.5 g NaAc•3H2O) to all tubes
(the extract will reach 40–45°C) and seal the tubes well (ensure that powder does not get
into the screw threads or rim of the tube).
6. Shake the tubes vigorously by hand for 1 min (using a motion from the arms more than
the wrist) with 3–5 tubes at once in each hand, ensuring that the solvent interacts well
with the entire sample and that crystalline agglomerates are broken up sufficiently during
shaking. (see Note 14).
7. Centrifuge the tubes at more than 3000g. The greater the force, the better for forming a
solid sample plug and providing potentially cleaner extracts.
8. Transfer needed amount (1–8 mL) of the MeCN extract (upper layer) at RT to the dispersive-SPE tubes containing 50 mg PSA (and C18 for fatty samples) plus 150 mg anhy-
250
Lehotay
drous MgSO4 per milliliter extract. For matrix blanks to be used for the five matrixmatched calibration standards, first combine the blank extracts (if multiple blanks were
extracted), then either transfer the needed amounts (1–8 mL) into separate dispersive SPE
tubes as with the sample extracts or proportionately scale up the dispersive SPE step to
obtain the extract volume needed for the standards after cleanup (see Subheadings 3.2.2.
and 3.2.3. for further explanation).
9. Seal the tubes well and mix by hand (or use a vortex mixer) for approx 30 s.
10. Centrifuge the dispersive SPE tubes at more than 3000g.
3.2.2. Options for Handling Extracts for Analysis
Depending on the LOQ needed, the chosen pesticide analytes, and analytical instruments and techniques used, 1–8 mL of the extract will be taken for dispersive-SPE
cleanup. This cleanup technique loses half of the extract volume to the powder reagents, and the extraction method yields 1-g/mL equivalent sample concentrations.
For GC–MS, approx 8 mg should be injected to generally achieve an LOQ below 10
ng/g, assuming that matrix interferences are not the limiting source of noise. If this
degree of sensitivity is needed, then either LVI (e.g., 8-µL injection) must be used or
the extracts must be concentrated. LVI is the simpler option, but if such a device is not
available on the GC instrument (or it does not provide acceptable results for certain
pesticide analytes), then splitless injection of the concentrated extract is the remaining
option. When performing the MeCN evaporation step in this option, it is convenient to
exchange solvent to toluene, which acts as a good keeper for the pesticides and has
benefits in traditional GC analysis (e.g., smaller vaporization expansion volume). Further details, including a comparison of GC injection solvents, are provided elsewhere
for this application (13,39).
In Option A, if the desired LOQ can be achieved in GC with injection of the MeCN
extract (using LVI or not), then a 1-mL aliquot is taken to minimize reagent costs (or
a larger volume is taken, and the procedure is scaled up appropriately at slightly greater
materials cost). In Option B, if direct injection of the MeCN extract in GC cannot
achieve the necessary LOQ using the available instrumentation, then 8 mL is taken for
dispersive SPE cleanup, and an extract concentration and solvent exchange step is
performed prior to GC analysis (LC injection volume can be more easily increased,
thus extract concentration is less of an issue in that case). Each of these options is
described as follows:
Option A. Use 1 mL extract in step 8, and then after step 10:
11a. Transfer 500 µL of the final extracts from the dispersive SPE tubes (or five 500-µL
aliquots of the combined matrix blank extract after dispersive SPE) to autosampler vials
for (LVI) GC–MS.
12a. Add 50 µL of the 2-ng/µL TPP working solution at RT to all extracts (to make 200-ng/g
equivalent concentration and 0.09% HAc, which improves stability of certain pesticides).
13a. Add 25 µL of MeCN to all sample extracts, the QC spike, the reagent blank, and the zero
standard (to compensate for the volume to be added to the calibration standards in the
next step).
14a. Follow procedures described in Subheading 3.2.3., Option A, for the four matrix blank
extracts to be used for matrix-matched calibration standards (w, x, y, and z standards).
QuEChERS Approach for Pesticides
251
15a. Cap and shake the vials to mix solutions, then uncap them.
16a. Transfer 150 µL of the extracts from each vial to a counterpart LC autosampler vial into
which 0.45 mL of 6.7 mM formic acid solution has been added (this is done to match the
organic solvent and formic acid contents in the initial LC mobile phase of 5 mM formic
acid in 25% MeOH).
17a. Cap all vials and conduct (LVI) GC–MS and LC–MS/MS analytical sequences according
to Subheadings 3.3. and 3.4.
Option B. Use 8 mL extract in step 8, and then after step 10:
11b. Transfer 250 µL of the MeCN extracts from the dispersive SPE tubes (or five 250-µL
aliquots of the combined matrix blank extract after dispersive SPE) to autosampler vials
for LC–MS/MS.
12b. Add 25 µL of the 2-ng/µL TPP working solution at RT to all vials and 12.5 µL of MeCN
to all sample extracts, the QC spike, the reagent blank, and the zero standard.
13b. Follow procedures described in Subheading 3.2.3., Option B, for the four matrix blank
extracts to be used for the w, x, y, and z standards.
14b. Add 860 µL of 6.7 mM formic acid solution to achieve the acid concentration and organic
solvent content at the initial LC mobile phase and cap all vials.
For evaporation and solvent exchange to toluene for GC–MS (without LVI):
15b. Transfer 4 mL of each extract (or five 4-mL aliquots of the combined matrix blank extract
after dispersive SPE) to 10- to 15-mL graduated centrifuge tubes containing 1 mL of
toluene and 400 µL of the 2-ng/µL TPP working solution added at RT.
16b. Evaporate the extracts at 50°C and sufficient N2 gas flow until volume is 0.3–0.5 mL.
17b. Follow procedures described in Subheading 3.2.3., Option B, for the four matrix blank
extracts to be used for the w, x, y, and z standards.
18b. Add toluene to take each extract up to the 1-mL mark
19b. Add anhydrous MgSO4 to reach the 0.2-mL mark on the tube and swirl to rinse above the
6-mL mark.
20b. Centrifuge the tubes at more than 600g.
21b. Transfer ≈0.6 mL of the final extract to the GC autosampler vials, and cap all vials.
22b. Conduct (LVI/)GC/MS and LC/MS-MS analytical sequences according to Subheadings
3.3. and 3.4.
3.2.3. Preparation of Matrix-Matched Calibration Standards
The concentration range of the matrix-matched calibration standards is to be
decided by the analyst, and these concentrations are listed as w, x, y, and z (given as
nanograms-per-gram equivalent concentrations with respect to the original sample).
As an example, if the LOQ of the method is 10 ng/g, then the four suggested concentrations of the standards are 10, 50, 250, and 1250 ng/g. In continuation of the procedures above, the instructions for the preparation of the matrix-matched calibration
standards are as follows:
Option A. If 1- to 2-mL aliquots of the extracts are taken for dispersive SPE in step
8, then only a single 15-g matrix blank is typically needed to provide enough extract
for the zero, w, x, y, and z standards. For the 0.5-g equivalent extracts described in step
14a, add 25 µL of the respective calibration standard spiking solution (w, x, y, and z) at
RT to the appropriate four matrix blank extracts (w, x, y, and z standards). Similarly, if
252
Lehotay
2-mL aliquots are taken in step 8, then 1-mL extracts are to be transferred in step 11a,
in which case add 50 µL of the respective calibration standard spiking solution (w, x,
y, and z) to the appropriate four matrix blank extracts (w, x, y, and z standards) in step 14a.
Option B. At least 22 mL of matrix blank extract is needed after dispersive SPE
cleanup (or ⱖ44 mL of initial extract) to prepare the zero, w, x, y, and z standards.
Depending on the matrix and water content, a 15-g sample will typically yield 11 mL
MeCN extract after centrifugation, thus four (but maybe five) 15-g blank samples
need to be extracted. For the w, x, y, and z standards in LC–MS/MS described in step
13b, add 12.5 µL of the respective calibration standard spiking solutions w, x, y, and z
at RT. For the w, x, y, and z standards in toluene for GC–MS as described in step 17b,
add 200 µL of the respective calibration standard spiking solution (w, x, y, and z) at
RT. The calibration standard spiking solutions for GC in this case should preferably
be in toluene. If the spiking solution is in MeCN, then 200 µL MeCN should also be
added to the other extracts in step 18b. Be aware that the presence of 20% MeCN may
lead to poor chromatography, and MeCN should not be added if an N-sensitive GC
detector (e.g., nitrogen–phosphorus detector) is used without a detector bypass vent.
3.3. Analysis of GC-Amenable Pesticides
Generic conditions are given next and in Table 2 for the GC–MS analysis of selected pesticides from the list in Table 1. The analyst may use many different sets of
conditions that offer equally valid results in the separation and detection of pesticides
of their particular interest. In fact, the analyst should optimize the given conditions to
yield the lowest LOQ for their chosen analytes in the shortest amount of time. The
selected ions for quantitation and identification should be made to maximize S/N ratios of the analytes while avoiding matrix interferences. Information about the expected retention times (tR) and intense ions in the mass spectra for hundreds of
pesticides are listed elsewhere (1,7,8). Commercial mass spectral libraries (e.g., National Institute of Standards and Technology [NIST] and Wiley) also contain the EI
spectra of hundreds of pesticides, which can help determine their tR and choose
quantitation masses when optimizing the GC conditions.
Otherwise, the way to determine the tR and mass spectrum for a pesticide is to inject
> 1 ng and look for the peak(s). The presence of the molecular ion (M+) in the spectrum helps ensure that the pesticide does not degrade during injection, and if no library
spectrum is available, it should be verified that the spectrum makes sense relative to
the structure of the pesticide. In general, the analyst should choose the ion(s) for
quantitation with the highest intensity at higher mass, but all selections should be verified to meet LOQ requirements in the matrix(es) of interest. Proper choice of
quantitation ions can often substantially reduce LOQ, especially in complex backgrounds.
For extracts in MeCN, inject only as much as needed to achieve the LOQ desired in
the analysis. Split mode (e.g., 10:1 split ratio for a 1-µL injection) may be all that is
needed for applications designed to detect pesticides >1 µg/g in the samples, but LVI
is required for maximal sensitivity. In most applications, 8 mg equivalent sample injected onto the column should be sufficient to achieve <10 ng/g LOQ for most pesticides. This would necessitate 8-µL injection in LVI of the 1-g/mL MeCN extracts
from Subheading 3.2.2., Option A. In this case, it is suggested to program the pro-
253
Analyte
tR (min)
Quant. ion(s) (m/z)
Methamidophos
Dichlorvos
Propoxur
Ethoprophos
Hexachlorobenzene
Lindane
Diazinon
Chlorothalonil
Chlorpyrifos-methyl
Carbaryl
Dichlofluanid
Chlorpyrifos
d10-Parathion (ISTD)
5.95
6.02
8.96
9.22
10.15
10.79
10.89
11.26
12.17
12.49
13.20
13.44
13.61
94,95, 141
109,185
110,152
158,200
282,284,286
181,183,219
179,276,304
264, 266,268
199,286,288
115,116,144
123, 224
199,314,316
301
Analyte
tR (min)
Dichlorobenzophenone
Cyprodinil
Penconazole
Tolylfluanid
Heptachlor epoxide
cis-Chlordane
p,p′-DDE
Dieldrin
Endosulfan sulfate
TPP (QC)
cis-Permethrin
trans-Permethrin
Coumaphos
13.85
14.39
14.57
14.68
14.80
15.80
16.47
16.63
18.27
18.50
20.54
20.66
20.73
Quant. ion(s) (m/z)
139, 250
224
213,248
137,181,238
237,353
237,272,375
246,316,318
263,277
237,272,387
326
183
183
226,334,362
QuEChERS Approach for Pesticides
Table 2
Conditions for the GC–MS Analysis of Selected Analytes, TPP, and the ISTD Using the Generic GC Method Described in the Text
Quant., quantitation.
253
254
Lehotay
grammable temperature vaporizer to start at 75°C for 3 min followed by a 200°C/min
temperature ramp to 275°C. A solid plug of Carbofrit or inert sorbent is typically
needed to contain the liquid solvent during the vaporization process in LVI (12,40,41).
For the 4-g/mL extracts in toluene, 2-µL splitless injection at 250°C should be satisfactory to achieve <10 ng/g LOQ. It is recommended to use a 1– 5-m phenylmethyldeactivated guard column as a retention gap to minimize solvent condensation effects
and better protect the analytical column. This also serves to reduce the effect of GC
maintenance on the tR of the analytes because the retention gap is shortened, not the
analytical column.
For GC, set helium head pressure on the column at 10 psi or flow to 1 mL/min with
systems capable of electronic pressure/flow control. After an appropriate time for solvent delay (e.g., approx 1.5 min in splitless and approx 4 min in LVI), a generic oven
temperature program for MeCN extracts is 75°C initial temperature ramped to 175°C
at 25°C/min, then to 225°C at 5°C/min, followed by a 25°C/min ramp to 290°C, at
which it is held for 10 min. In the case of toluene injections, the initial oven temperature should be increased to 100°C and everything else kept the same. Of course, other
temperature programs may be used, but in any case, peak shapes should be Gaussian,
and peak widths at half-heights should be less than 5 s.
For the MS, the analyst should follow the instructions provided by the instrument
manufacturer to optimize the system for detection of the pesticide analytes. Prior to
injection of the sequence, a system suitability test should be made, such as autotuning
of the MS, to help ensure that analytical quality is acceptable (15,16,42). It is suggested that the calibration standards be dispersed throughout the sequence to demonstrate adequate instrument performance over the entire time-frame that the samples
are injected.
3.4. Analysis of LC-Type Pesticides
In the case of LC–MS/MS, the analyst should follow the instrument manual guidelines to set the ion source temperature, gas flows, voltage potentials, and other general
parameters for the particular instrument and analytical needs. Based on the LC conditions described below, the MS/MS detection parameters for each analyte should be
optimized by using a syringe pump to infuse approx 1 ng/µL of the pesticide in 5 mM
formic acid in 1/1 MeOH/water solution at 0.3 mL/min into the source. Most of the
pesticides will ionize well in ESI-positive (+) mode, thus the M+1 mass spectral peak
should first be optimized, and then conditions for collision-induced dissociation to
maximize the S/N ratio of the first MS/MS transition should be determined. Most
instruments have automated programs to optimize the parameters with little analyst
intervention. It is not difficult also to test the signals in negative mode for comparison
purposes, but nearly all of the LC-type analytes listed in Table 1 ionize sufficiently
well in ESI+. In some cases, Na+ adducts with the ionized pesticides form in the ion
source. This is not necessarily problematic if all of the analyte generates the adduct
and if the result is quantitatively reproducible.
Each instrument will give somewhat different optimized settings, even for the same
model, but sensitivity will not typically be a problem. With the latest instruments,
QuEChERS Approach for Pesticides
255
Table 3
Conditions for the LC–MS/MS Analysis of Selected Pesticides in a Triple Quadrupole
Instrument Using ESI+ Mode at the LC Conditions Given in the Text
Analyte
Methamidophos
Pymetrozine
Acephate
Carbendazim
Thiabendazole
Imidacloprid
Imazalil
Thiophanate-methyl
Dichlorvos
Carbaryl
Dichlofluanid
Ethoprophos
Cyprodinil
Tolylfluanid
Penconazole
tR (min) Precursor ion (m/z) Product ion (m/z) Collision energy (V)
9.6
10.0
11.1
11.9
13.2
15.9
16.3
18.8
19.0
19.3
20.9
21.2
21.2
21.3
21.5
141.8
217.9
138.8
191.8
201.8
255.9
296.8
342.8
220.7
202.2
332.7
242.8
225.9
346.7
283.8
112.0
105.0
143.0
160.0
174.9
209.0
159.0
151.0
127.0
145.0
223.8
173.0
108.0
237.9
159.0
17
27
19
25
37
21
31
29
23
13
17
21
35
15
39
LOQ < 10 ng/g can typically be achieved with a 10-µL injection volume for the extracts of 0.25-g/mL equivalent sample concentrations. The water and acid contents of
the extract closely match the initial LC mobile phase; thus, a larger volume may be
injected without seriously affecting peak shapes. Therefore, a lower LOQ can usually
be achieved by injecting a larger volume of the extract if needed.
As an example, generic LC conditions for the analysis of multiple pesticide residues are as follows: 0.3-mL/min flow rate; reservoirs to contain 5 mM formic acid in
(1) water and (2) MeOH; gradient program of 25% solution B ramped to 100% linearly over 15 min, then held for an additional 15 min. After 30 min, the flow can be
increased to 0.5 mL/min and the mobile phase returned to 75% solution A over the
course of 2 min and allowed to equilibrate for 6 min. A divert valve should be placed
between the column outlet and ion source to eliminate the introduction of salts and
early eluting matrix components into the MS instrument before the tR of the first
analyte and any coextracted matrix components that may elute after the last pesticide
of interest. Some pesticides may give broad or dual peaks if the mobile phase pH is not
acidic enough. In this case, the formic acid content may be increased in an attempt to
provide better chromatographic peak shapes. Table 3 lists sample conditions for 15
selected pesticides in LC–MS/MS.
Just as with GC–MS, QA protocols should be followed and system suitability tests
conducted prior to analyzing a sequence of samples. Regular preventive maintenance
must be done to ensure adequate operation of the instruments. Inject the matrix blank
to determine if a significant interferant is present at the tR of the analytes. No evidence
of carryover should be present in the reagent blank, which should be injected after the
most highly concentrated standard in the sequence.
256
Lehotay
3.5. Data Analysis
Quantitation is based on least-linear-squared calibration of analyte peak areas divided by the ISTD peak areas plotted vs analyte concentration. The ratio of analyte
peak area to ISTD peak area becomes the signal S. The analyte concentrations in the
matrix-matched standards on a per-sample basis (nanogram per gram) can be determined by multiplying the volume (microliters) added to the extract by the analyte
concentrations in the added solutions (nanograms per microliters) and dividing by the
equivalent amount (grams) of sample in the extract. The concentrations (in nanograms
per gram) C of the pesticide analytes in the samples and QC matrix spike are determined from the equation
C = (S − y intercept)/Slope
If there are no interferences, the y-intercept should be nearly zero, and the correlation coefficient of the slope should be >0.99. In some circumstances, a nonlinear relationship occurs in the calibration plot and a quadratic best-fit curve may provide better
correlation and results. The TPP is a QC measure to isolate the variability of the analytical step from the sample preparation method. The volumes of the final extracts and
each preceding step are carefully controlled in the sample preparation protocol, and
ideally the ISTD would not need to be used to achieve equally accurate results. Pipets,
syringes, and balances should be periodically calibrated to ensure accuracy. However,
random and systematic errors in volumetric transfers are inherent in analytical methods, and the ISTD should improve the accuracy of the results. The recoveries of the
ISTD can be assessed by comparing the peak areas of the ISTD in the samples with
those from the calibration standards. The TPP/ISTD peak area ratio should remain
consistent (<10% relative standard deviation) in the method, and if any extract gives a
substantially different ratio from the others, then the results from that extract should
be questioned. Furthermore, if the QC spike yields recoveries <70% or >120%, then
the results from all the samples should be questioned. If all pesticide recoveries outside the acceptable range are the same, then a systematic bias is indicated. If variable
recoveries are obtained, then a systematic bias is not likely to be the source of the
problem. Many pesticides can be analyzed by both LC–MS/MS and GC–MS, and the
comparison of their results from both distinct methods can be invaluable in isolating
any problems that may occur with one of the instruments or techniques.
4. Notes
1. NaAc•3H2O may be substituted for anhydrous NaAc, but 1.7 g per gram sample must be
used rather than 1 g anhydrous NaAc per gram sample.
2. Heat bulk quantities of anhydrous MgSO4 to 500°C for longer than 5 h to remove phthalates and any residual water prior to its use in the laboratory, but this is not critical.
3. Aminopropyl SPE sorbent can be substituted for PSA, but 75 mg per milliliter of extract
should be used.
4. Toluene is the most suitable solvent for long-term storage (>10 yr) of pesticide stock
solutions in general because of its slower evaporation rate, miscibility with MeCN, and
the higher solubility and stability of pesticides in toluene compared to other solvents.
However, not all pesticides can be dissolved at 10 mg/mL in toluene. In these cases,
QuEChERS Approach for Pesticides
5.
6.
7.
8.
9.
10.
11.
257
MeCN, acetone, MeOH, or ethyl acetate should be used, but long-term stability may become an issue, and old solutions should be replaced more often.
The choice of ISTD is very important because it must not already be present in the sample,
but be completely recovered in the method for detection in both GC–MS and LC–MS/MS
(otherwise, a pair of ISTDs may be used). A relatively inexpensive deuterated pesticide
(d10-parathion) was chosen as the ISTD in this protocol. Deuterated chlorpyrifos or
chlorpyrifos-methyl are more suitable for a greater range of selective GC detectors, but
they are more expensive. It is also possible to use an uncommon compound as the ISTD,
but its suitability would have to be determined.
In this protocol, 250 is the maximum number of pesticides that can be added to make this
solution, which will consist of 100% toluene if the stock standards are all in toluene. This
is not ideal for spiking of the sample or preparation of calibration standard spiking solutions. The stock standards can be prepared in MeCN, but some pesticides will have reduced stability, which is significantly improved in 0.1% HAc solution, but degradation is
not eliminated (39). An alternative approach is to prepare mixtures of pesticides in stock
solutions by dissolving multiple pesticide reference standards in the same vial.
The TPP working standard is prepared in MeCN with 1% HAc because when it is added
to the MeCN extracts in steps 12a or 12b and 15b, the extract will contain 0.09% HAc for
improved stability of certain pesticides (e.g., chlorothalonil, captan, folpet, tolylfluanid,
dichlofluanid, carbaryl).
To speed the process greatly, the density of the powders can be determined and scoops
made of the appropriate volume, but weighing should still be done to check consistency
(reagent weights ± 5% deviation from the stated amount are acceptable). The containers
should be sealed during storage and can be refilled and reused without cleaning between
uses. A commercial product (#CUMPSC2CT) containing 50 mg of PSA + 150 mg anh.
MgSO4 is available from United Chemical Technologies.
If samples contain ⱖ 1% fat, add the same amount of C18 sorbent as PSA (in addition to
PSA) in centrifuge tubes for dispersive SPE. As the fat content increases, a third phase
(lipids) will form in the extraction tube, and the recoveries of nonpolar pesticides will
decrease as they partially partition into the lipid layer. The most nonpolar pesticides (e.g.,
hexachlorobenzene, DDE) will give < 70% recovery at approx 5% fat content, but relatively polar GC-amenable and LC-type pesticides are completely recovered at >15% fat
(14). A commercial product (#CUMPSC18CT) containing 50 mg each of PSA and C18 +
150 mg anh. MgSO4 is available from United Chemical Technologies.
If none of the analytes have planar structures, then GCB can be used to provide additional
cleanup, especially for removal of chlorophyll, sterols, and planar matrix coextractives.
In this case, add the same amount of GCB as PSA and C18 (50 mg each per 1 mL of
extract) in centrifuge tubes for dispersive-SPE. Planar pesticides include terbufos, thiabendazole, hexachlorobenzene, and quintozene, among many others (11).
The advantages of this approach include (1) the extracted portion is highly representative
of the initial sample; (2) the sample is well comminuted to improve extraction by shaking
rather than blending; (3) less time is spent on the overall homogenization process than
trying to provide equivalent homogenization of the large initial sample using the chopper
alone; and (4) a frozen subsample is available for reanalysis if needed. The sample homogenization step is a critical component in the overall sample preparation process; unfortunately, many analysts do not pay adequate attention to this important step. If the
sample is not homogenized properly, then the analytical results will not be as accurate as
they could be, independent of the performance of the sample preparation and analytical steps.
258
Lehotay
12. To provide the most homogeneous comminuted samples, frozen conditions, sufficient
chopping time, and appropriate sample size to chopper volume should be used. Use of
frozen samples also minimizes degradative and volatilization losses of certain pesticides
(e.g., dichlorvos, chlorothalonil, dichlofluanid). If best results of susceptible pesticides
are needed, then cut the food sample into 2- to 5-cm3 portions with a knife and store the
sample in the freezer prior to processing. Cryogenic blending devices, liquid nitrogen, or
dry ice may also be used (but make sure all dry ice has sublimed before weighing samples
and ensure that water condensation is minimal, especially in a humid environment). For
further information about sample processing in pesticide residue analysis of foods, the
analyst should refer to several publications on the topic (43–48).
13. An uncommon or deuterated pesticide standard may be spiked into the sample during
homogenization to determine the effectiveness of the procedure through the measurement of recovery and reproducibility using the technique and specific devices. For typical
applications, the recovery should be > 70%, with relative standard deviation < 20% for a
100- to 500-ng/g fortification level.
14. Alternately, do not seal the tubes and use a probe blender for extraction, taking care not to
overheat the extract. Another option is to extract using sonication. These stronger measures may be needed to ensure that any bound residues are extracted. Fruits, vegetables,
and other high-moisture samples do not typically interact strongly with the residues, and
shaking alone is usually acceptable for extraction of nearly all pesticides. However, dry
or porous/sorptive sample types, such as grains and soils, require blending, higher temperature, more acidic or basic conditions, or more time to completely extract those residues prone to strong matrix interactions.
Acknowledgment
Mention of brand or firm name does not constitute an endorsement by the US Department of Agriculture above others of a similar nature not mentioned.
References
1. Food and Drug Administration. (1999) Pesticide Analytical Manual Volume I:
Multiresidue Methods, 3rd ed., US Department of Health and Human Services, Washington, DC. Available at: http://www.cfsan.fda.gov/~frf/pami3.html
2. Luke, M. A., Froberg, J.E., and Masumoto, H. T. (1975) Extraction and cleanup of organochlorine, organophosphate, organonitrogen, and hydrocarbon pesticides in produce for
determination by gas–liquid chromatography. J. Assoc. Off. Anal. Chem. 58, 1020–1026.
3. Specht, W. and Tilkes, M. (1980) Gas chromatographische bestimmung von rückständen
an pflanzenbehandlungsmitteln nach clean-up über gel-chromatographie und minikieselgel-säulen-chromatographie. Fresenius J. Anal. Chem. 301, 300–307.
4. Lee, S. M., Papathakis, M. L., Hsiao-Ming, C. F., and Carr, J. E. (1991) Multipesticide
residue method for fruits and vegetables: California Department of Food and Agriculture.
Fresenius J. Anal. Chem. 339, 376–383.
5. Andersson, A. and Pålsheden, H. (1991) Comparison of the efficiency of different GLC
multi-residue methods on crops containing pesticide residues. Fresenius J. Anal. Chem.
339, 365–367.
6. Cook, J., Beckett, M. P., Reliford, B., Hammock, W., and Engel, M. (1999) Multiresidue
analysis of pesticides in fresh fruits and vegetables using procedures developed by the
Florida Department of Agriculture and Consumer Services. J. AOAC Int. 82, 1419–1435.
QuEChERS Approach for Pesticides
259
7. General Inspectorate for Health Protection. (1996) Analytical Methods for Pesticide Residues in Foodstuffs, 6th ed., Ministry of Health Welfare and Sport, The Netherlands.
8. Fillion, J., Sauvé, F., and Selwyn, J. (2000) Multiresidue method for the determination of
residues of 251 pesticides in fruits and vegetables by gas chromatography/mass spectrometry and liquid chromatography with fluorescence detection. J. AOAC Int. 83, 698–713.
9. Sheridan, R. S. and Meola, J. R. (1999) Analysis of pesticide residues in fruits, vegetables, and milk by gas chromatography/tandem mass spectrometry. J. AOAC Int. 82,
982–990.
10. Lehotay, S. J. (2000) Determination of pesticide residues in nonfatty foods by supercritical
fluid extraction and gas chromatography/mass spectrometry: collaborative study. J. AOAC
Int. 83, 680–697.
11. Anastassiades, M., Lehotay, S. J., Stajnbaher, D., and Schenck, F. J. (2003) Fast and easy
multiresidue method employing acetonitrile extraction/partitioning and “dispersive solidphase extraction” for the determination of pesticide residues in produce. J. AOAC Int. 86,
412–431.
12. Lehotay, S. J., Hiemstra, M., van Bodegraven, P., and de Kok, A. (2005) Validation of a
fast and easy method for the determination of more than 200 pesticide residues in fruits
and vegetables using gas and liquid chromatography and mass spectrometric detection. J.
AOAC Int. 88, 595–614.
13. Lehotay, S. J., Mastovská, K., and Lightfield, A. R. (2005) Use of buffering to improve
results of problematic pesticides in a fast and easy method for residue analysis of fruits
and vegetables. J. AOAC Int. 88, 615–629.
14. Lehotay, S. J., Mastovská, K., and Yun, S.-J. (2005) Evaluation of two fast and easy
methods for pesticide residue analysis in fatty food matrices. J. AOAC Int. 88, 630–638.
15. Fajgelj, A. and Ambrus, Á. (eds.) (2000) Principles and Practices of Method Validation,
Royal Society of Chemistry, Cambridge, UK, pp. 179–295.
16. Hill, A. R. C. and Reynolds, S. L. (1999) Guidelines for in-house validation of analytical
methods for pesticide residues in food and animal feed. Analyst 124, 953–958.
17. Stry, J. J., Amoo, J. S., George, S. W., Hamilton-Johnson, T., and Stetser, E. (2000)
Coupling of size-exclusion chromatography to liquid chromatography/mass spectrometry for determination of trace levels of thifensulfuron-methyl and tribenuron-methyl in
cottonseed and cotton gin trash. J. AOAC Int. 83, 651–659.
18. Erney, D. R., Gillespie, A. M., Gilvydis, D. M., and Poole, C. F. (1993) Explanation of
the matrix-induced chromatographic enhancement of organophosphorus pesticides during open tubular column gas chromatography with splitless or hot on-column injection
and flame photometric detection. J. Chromatogr. 638, 57–63.
19. Erney, D. R. and Poole, C. F. (1993) A study of single compound additives to minimize
the matrix induced chromatographic response enhancement observed in the gas chromatography of pesticide residues. J. High Resolut. Chromatogr. 16, 501–503.
20. Erney, D. R., Pawlowski, T. M., and Poole, C. F. (1997) Matrix-induced peak enhancement of pesticides in gas chromatography: is there a solution? J. High Resolut.
Chromatogr. 20, 375–378.
21. Schenck, F. J. and Lehotay, S. J. (2000) Does further clean-up reduce the matrix enhancement effect in gas chromatographic analysis of pesticide residues in food? J. Chromatogr.
A 868, 51–61.
22. Hajslová, J., Holadová, K., Kocourek, V., et al. (1998) Matrix-induced effects: a critical point in gas chromatographic analysis of pesticide residues. J. Chromatogr. A 800,
283–295.
260
Lehotay
23. Hajslová, J. and Zrostlíková, J. (2003) Matrix effects in (ultra)trace analysis of pesticide
residues in food and biotic matrices. J Chromatogr A. 1000, 181–197.
24. Anastassiades, M., Mastovská, K., and Lehotay, S. J. (2003) Evaluation of analyte
protectants to improve gas chromatographic analysis of pesticides. J. Chromatogr. A
1015, 163–184.
25. Mastovská, K. and Lehotay, S.J. (submitted) Optimization and evaluation of analyte
protectants in gas chromatographic analysis. Anal. Chem.
26. Mol, H. G., van Dam, R. C., and Steijger, O. M. (2003) Determination of polar organophosphorus pesticides in vegetables and fruits using liquid chromatography with tandem
mass spectrometry: selection of extraction solvent. J. Chromatogr. A 1015, 119–127.
27. Klein, J. and Alder, L. (2003) Applicability of gradient liquid chromatography with tandem mass spectrometry to the simultaneous screening for about 100 pesticides in crops.
J. AOAC Int. 86, 1015–1037.
28. Zrostlíková, J., Hajslová, J., Poustka, J., and Begany, P. (2002) Alternative calibration
approaches to compensate the effect of co-extracted matrix components in liquid chromatography–electrospray ionisation tandem mass spectrometry analysis of pesticide residues in plant materials. J. Chromatogr. A 973, 13–26.
29. Niessen, W. M. A. (ed.) (2001) Current Practice of Gas Chromatography–Mass Spectrometry, Dekker, New York.
30. Mastovská, K. and Lehotay, S. J. (2003) Practical approaches to fast gas chromatography–mass spectrometry. J. Chromatogr. A 1000, 153–180.
31. Cochran, J. W. (2002) Fast gas chromatography–time-of-flight mass spectrometry of
polychlorinated biphenyls and other environmental contaminants. J. Chromatogr. Sci.
40, 254–268.
32. Niessen, W. M. (2003) Progress in liquid chromatography–mass spectrometry instrumentation and its impact on high-throughput screening. J Chromatogr A 1000, 413–436.
33. Amirav, A. and Dagan, S. (1997) A direct sample introduction device for mass spectrometry studies and gas chromatography mass spectrometry analyses. Eur. Mass Spectrom. 3,
105–111.
34. Lehotay, S. J. (2000) Analysis of pesticide residues in mixed fruit and vegetable extracts
by direct sample introduction/gas chromatography/tandem mass spectrometry. J. AOAC
Int. 83, 680–697.
35. Patel, K., Fussell, R. J., Goodall, D. M., and Keely, B. J. (2003) Analysis of pesticide
residues in lettuce by large volume–difficult matrix introduction–gas chromatography–
time of flight–mass spectrometry (LV–DMI–GC–TOF–MS). Analyst 128, 1228–1231.
36. Matisová, E. and Domotorová, M. (2002) Fast gas chromatography and its use in trace
analysis. J. Chromatogr A 1000, 199–221.
37. Amirav, A., Gordin, A., and Tzanani, N. (2001) Supersonic gas chromatography/mass
spectrometry. Rapid Commun. Mass Spectrom. 15, 811–820.
38. Mastovská, K., Lehotay, S. J., and Hajslová, J. (2001) Optimization and evaluation of
low-pressure gas chromatography–mass spectrometry for the fast analysis of multiple
pesticide residues in a food commodity. J. Chromatogr. A 926, 291–308.
39. Mastovská, K. and Lehotay, S. J. (submitted) Evaluation of common organic solvents for
gas chromatographic analysis and stability of multiclass pesticide residues. J.
Chromatogr. A.
40. Martinez Vidal, J. L., Arrebola, F. J., and Mateu-Sanchez, M. (2002) Application to routine analysis of a method to determine multiclass pesticide residues in fresh vegetables by
gas chromatography/tandem mass spectrometry. Rapid Commun. Mass Spectrom. 16,
1106–1115.
QuEChERS Approach for Pesticides
261
41. Rosenblum, L., Hieber, T., and Morgan, J. (2001) Determination of pesticides in composite dietary samples by gas chromatography/mass spectrometry in the selected ion monitoring mode by using a temperature-programmable large volume injector with
preseparation column. J. AOAC Int. 84, 891–900.
42. Soboleva, E. and Ambrus, Á. (2004). Application of a system suitability test for quality
assurance and performance optimisation of a gas chromatographic system for pesticide
residue analysis. J. Chromatogr. A 1027, 55–65.
43. Young, S. J., Parfitt, C. H., Jr., Newell, R. F., and Spittler, T. D. (1996) Homogeneity of
fruits and vegetables comminuted in a vertical cutter mixer. J. AOAC Int. 79, 976–980.
44. Lyn, J. A., Ramsey, M. H., Fussell, R. J., and Wood, R. (2003) Measurement uncertainty
from physical sample preparation: estimation including systematic error. Analyst 128,
1391–1398.
45. Hill, A. R. C., Harris, C. A., and Warburton, A. G. (2000) Effects of sample processing on
pesticide residues in fruits and vegetables, in Principles and Practices of Method Validation (Fajgelj, A. and Ambrus, Á., eds.), Royal Society of Chemistry, Cambridge, UK, pp.
41–48.
46. Maestroni, B., Ghods, A., El-Bidaoui, M., et al. (2000) Testing the efficiency and uncertainty of sample processing, in Principles and Practices of Method Validation (Fajgelj,
A. and Ambrus, Á., eds.), Royal Society of Chemistry, Cambridge, UK, pp. 49–88.
47. Lehotay, S. J., Aharonson, N., Pfeil, E., and Ibrahim, M. A. (1995) Development of a
sample preparation technique for supercritical fluid extraction in the multiresidue analysis of pesticides in produce. J. AOAC Int. 78, 831–840.
48. Fussell, R. J., Jackson-Addie, K., Reynolds, S. L., and Wilson, M. F., (2002) Assessment
of the stability of pesticides during cryogenic sample processing. 1. Apples. J. Agric.
Food Chem. 50, 441–448.
Determination of OP Pesticide Residues in Vegetable Oils
263
20
Determination of Organophosphorus Pesticide Residues
in Vegetable Oils by Single-Step Multicartridge Extraction
and Cleanup and by Gas Chromatography With Flame
Photometric Detector
Alfonso Di Muccio, Anna M. Cicero, Antonella Ausili,
and Stefano Di Muccio
Summary
The method presented is applicable to the determination of organophosphorus (OP)
pesticide residues in vegetable oils. The method performs in a single step an on-column
extraction and cleanup of OP pesticide residues by means of a system of three cartridges.
A solution of 1 g oil in n-hexane is loaded into an Extrelut-NT3 cartridge (large-pore
diatomaceous material). The OP pesticide residues are extracted by eluting the cartridge
with 20 mL acetonitrile, which is cleaned up by passing through a silica and a C18 cartridge connected on-line to the Extrelut NT-3 cartridge. A few milligrams of lipid is
carried over into the eluate, which after concentration and solvent exchange is directly
amenable to determination by gas chromatography (GC) with flame photometric detector with optical filter for phosphorus compounds (FPD-P). Recovery values for 45 OP
pesticide residues are reported at two spiking levels. In the lower concentration range
tested (0.09–0.60 mg/kg), satisfactory results (74–86%) were obtained for 39 OP pesticides; exceptions were formothion (5%), disulfoton (32%), phosalone (54%), demetonS-methyl sulfone (60%), fenthion (62%), and borderline phosphamidone (68%). In the
higher concentration range tested (0.38–2.35 mg/kg), satisfactory results (82–109%)
were obtained for 43 OP pesticides; exceptions were formothion (48%) and disulfoton
(53%). Compared to conventional techniques, such as liquid–liquid partition and sizeexclusion chromatography (SEC), the method described is faster and simpler, requires
minimal solvents and essentially only disposable items, and does not require skilled operators or maintenance of costly apparatus.
Key Words: C18 cleanup; extraction; flame photometric detector; gas chromatography; multicartridge cleanup; organophosphorus pesticide residues; partition cleanup;
solid–matrix partition; vegetable oil.
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
263
264
Di Muccio et al.
1. Introduction
Organophosphorus pesticides (OP) are a class of compounds that includes derivatives of phosphoric, phosphorous, thiono-phosphoric, and thion-thiolo phosporic acids
esterified with methyl or ethyl and different alcohol groups. Depending on the alcoholic moiety, the polarity of OP pesticides ranges from water-soluble compounds such
as dimethoate to lipophilic compounds such as bromophos-ethyl. The majority of OP
pesticides are insecticides with anticholinesterase activity. OP pesticides are used in
agriculture, for the control of eso- and endoparasites of animals, and for civil uses.
Depending mainly on the chemical stability and the dose, time, and mode of application, pesticide residues may occur in crops and derived products. Regarding vegetable oils, residues of OP pesticides are likely to occur essentially in “virgin” olive oil
because it is produced without chemical treatments. In contrast, seed oils usually undergo chemical refining, including alkaline treatment, which cleaves the ester bond of
OP pesticides.
Extraction of OP pesticide residues from oils is usually carried out by (1) liquid–
liquid partition in a separatory funnel between n-hexane and acetonitrile (1,2), in which
the OP pesticides partition into the acetonitrile phase, and the major part of the oil
remains in the apolar phase (n-hexane), or (2) size-exclusion chromatography (3–7),
in which the major part of the lipid matrix is eluted in the excluded volume and is
separated from the OP pesticides, which have relatively lower molecular masses than
triglycerides.
The method described here is based on a separation of OP pesticide residues from
lipid material by a liquid–liquid partition carried out on a disposable, ready-to-use
cartridge filled with large-pore diatomaceous material (solid–matrix partition). A silica
gel cartridge and a C18 cartridge, connected in series downstream of the partition
cartridge, provide further removal of polar and apolar components. The identification
and determination are carried out by gas chromatography (GC) with flame photometric detector with optical filter for phosphorus compounds (FPD-P).
The solid–matrix partition has been able to extract different classes of pesticide
residues from fatty matrices (8–12). Compared to conventional methods, it is simple
and fast, requires a minimum of solvents and essentially only disposable items, and
does not require skilled operators or maintenance of costly apparatus.
2. Materials
1.
2.
3.
4.
Extrelut NT-3 cartridge (e.g., E. Merck, cat. no. 1.15095.0001, Darmstadt, Germany).
Sep-Pak silica cartridge (e.g., Waters, part no. 51900, Milford, MA).
Sep-Pak C18 cartridge (e.g., Waters, part no. 51910).
Solvents: n-hexane, acetonitrile, methanol, acetone, pesticide residues grade, or analytical reagent grade redistilled from an all-glass apparatus.
5. Solvent mixtures: acetonitrile saturated with n-hexane, used for solid–matrix partition (in
a separatory funnel with polytetrafluoroethylene stopcock, shake acetonitrile with some
n-hexane and let phases separate; prepare daily some time before use to allow for phase
separation); iso-octane plus acetone (80:20 v/v), used to dissolve the sample extracts for
the GC analysis.
6. Triphenylphosphate (TPP) internal standard.
Determination of OP Pesticide Residues in Vegetable Oils
265
7. Gas chromatograph with twin injectors, twin columns, twin detectors, and typical instrument setup and operating conditions:
• autosampler/autoinjector
• split/splitless injector, operated in pulsed (25 psi for 2 min) splitless mode with a 1min purge-off time, with a dual-tapered deactivated glass liner and temperature set at
240°C
• capillary, fused-silica columns, either SPB 1 or SPB 5, and SPB-1701, 30 m × 0.25
mm id × 0.25-µm film thickness, with an uncoated deactivated retention gap, 2.5 m ×
0.25 mm id
• temperature program of the column oven: 60°C (2 min), 10°C/min to 160°C, then
3°C/min to 260°C, finally at 260°C (20 min); total time 65 min
• helium carrier gas supplied through electronic pressure control module at 1.5 mL/min
(set at room temperature) in constant-flow mode
• FPD-P; temperature of detector base set at 250°C; nitrogen as auxiliary gas; hydrogen
and airflow rates to the detector set according to the manufacturer’s directions
3. Methods
3.1. Preparation of the Analytical Sample and the Reduced
Analytical Sample
If the laboratory sample has been kept in a refrigerator, allow it to warm to room
temperature. Shake the bottle or can so that the material inside can be considered
homogeneous (analytical sample). If the laboratory sample is made up of several
bottles or cans, take from each vessel an amount of material proportional to the content size. Combine the aliquots and mix thoroughly (reduced analytical sample).
3.2. Analytical Procedure
1. Weigh in a 10-mL test tube an amount of the analytical sample (or reduced analytical
sample) close to 1 g (±0.01 g) (test sample). Add 1 mL n-hexane and mix well. Using a
Pasteur pipet, transfer the solution into an Extrelut NT-3 cartridge. Apply the solution as
close as possible to the upper surface of the Extrelut NT-3 cartridge. Avoid touching the
inner wall of the cartridge. Let the solution drain into the filling material. Wash the test
tube three times with 0.5 mL n-hexane and transfer the washings into the Extrelut NT-3
cartridge. Let the washings drain into the filling material. Wait 10 min to obtain an even
distribution (see Note 1).
2. Connect the short end of a Sep-Pak silica cartridge to the Luer tip of the Extrelut NT-3
cartridge. Cut away 0.5 cm of the longer end of the silica cartridge. Then, connect a SepPak C18 cartridge to the Sep-Pak silica cartridge using a short length of glass tube, typically 10 × 4 mm ed × 2 mm id (see Fig. 1). Cut the end of the C18 cartridge in a fluted
mouth shape. Arrange for collection of the eluate in a preweighed (±0.0001 g) 50-mL
Erlenmeyer flask. Elution is carried out under gravity alone (see Note 2).
3. Wash the test tube with five 1-mL portions of acetonitrile saturated with n-hexane and
transfer the washings into the Extrelut NT-3 cartridge. Elute the system of the three combined cartridges with three additional 5-mL portions of acetonitrile saturated with n-hexane. For both washings and eluting solvent, apply each portion after the previous one has
just disappeared into the filling material. If elution does not start spontaneously, it is
possible to force the flow with slight pressure (see Note 3).
266
Di Muccio et al.
Fig. 1. Assembly of the three cartridges for extraction and cleanup and syringe assembly to
force the flow temporarily.
4. Add 4 mL methanol to the combined eluates and concentrate cautiously to dryness by
rotatory evaporator (55°C bath temperature, reduced pressure) (see Note 4).
5. To check the efficiency of the lipid removal, weigh the Erlenmeyer flask and calculate by
difference the mass of lipid residue. For olive oil, it is generally a few milligrams and is
compatible with the GC injection systems (see Note 5).
6. Dissolve the residue in 1 mL iso-octane plus acetone (80:20 v/v) and add the internal
standard solution.
Determination of OP Pesticide Residues in Vegetable Oils
267
3.3. Identification
Analyze by GC/FPD-P by injecting into two GC columns of different polarity. The
minimum identification criterion is based on matching the retention times of the
analytes (both absolute and relative to the internal standard) in the sample run with
those obtained in the calibrant solution run in the same sequence of analyses. Whenever possible, a confirmation by GC–mass spectrometry (GC–MS) or liquid chromatography–mass spectrometry (LC–MS) should be carried out.
3.4. Determination and Calculation
On both GC columns, the quantitation of each compound is carried out by comparing its peak area in the sample run to that in the standard solution run. The working
standard solution used for quantitation should contain an amount of sample residue
comparable to that in the extract of the sample to be analyzed (matrix-matched
calibrant) (see Note 6).
Quantitation can be carried out according to a calibration curve, by interpolation
between the responses of two calibrant solutions that encompass the response in the
sample run, or by proportion to the response of a calibrant solution comparable within
±50% to that in the sample run (±10% if the level of the determination is close to the
maximum residue limit). The concentration of the pesticide in the sample is given by
the formula
mg/kg = µg/g = [(Ra,i/IS)s × (Rµg,i/IS)c/(Ra,i/IS)c] × [(µgIS)s/g]
where (Ra,i/IS)s and (Ra,i/IS)c are the ratios of the peak area of the ith compound to
the area of ISTD in the sample and in the calibrant solution, respectively; (Rµg,i/IS)c
is the ratio of the amount of the ith compound to the amount of ISTD in the calibrant
solution; (µgIS)s is the amount in µg of ISTD in the sample solution; and g is the
amount in grams of the test sample in the sample solution. Usually, the result is not
corrected for the recovery value.
3.5. Checking the Recovery of the Method
Prepare spiked samples as follows: Analyze the sample of oil to be spiked and
check the absence of interferences with the compounds to be determined. Samples
spiked at different levels can be obtained by adding to a test tube 1 g oil and 1 mL
standard solution in n-hexane at appropriate concentration and then processing the
spiked sample as described in the method; otherwise, in a 10-mL test tube, add 1 g oil
and the following volumes of standard solution:
Standard solution
(µL)
5
10
20
50
(µg/mL)
Compound
(µg)
Spiking level
(mg/kg)
10
10
10
10
0.05
0.1
0.2
0.5
0.05
0.1
0.2
0.5
268
Di Muccio et al.
Table 1
Mean (N = 6) Recovery Values of 45 Organophosphorus Pesticides From 1 g Olive Oil Spiked
at Two Different Levels (ISO Names Used)
p-valuea
Pesticide
Spiking level
(mg/kg)
Recovery (%),
mean (N = 6) ± SD
Lb
Hc
0.77
1.92
0.60
0.58
1.03
0.60
0.79
0.46
0.76
0.58
2.35
1.17
1.60
77.2 ± 5.7
77.5 ± 5.1
95.5 ± 3.5
79.5 ± 5.2
99.9 ± 4.1
98.1 ± 6.2
81.6 ± 3.9
97.0 ± 6.2
98.2 ± 4.7
92.7 ± 4.8
80.5 ± 4.3
97.0 ± 3.4
59.7 ± 4.8
98.2 ± 4.7
91.8 ± 3.7
94.1 ± 3.7
96.2 ± 4.3
93.3 ± 4.2
95.6 ± 4.8
98.4 ± 5.4
103.0 ± 5.7
101.1 ± 5.0
93.1 ± 4.0
100.0 ± 5.2
87.4 ± 4.7
81.6 ± 4.8
97.9 ± 2.8
74.4 ± 4.7
81.7 ± 5.0
94.6 ± 4.6
93.4 ± 3.5
31.6 ± 4.1
96.0 ± 6.1
98.6 ± 2.8
97.9 ± 5.8
84.7 ± 5.5
81.1 ± 5.9
80.2 ± 6.0
62.3 ± 5.5
94.6 ± 5.2
81.3 ± 3.9
5.2 ± 4.7
85.9 ± 4.8
109.5 ± 4.6
97.8 ± 3.9
82.3 ± 6.2
84.6 ± 5.7
80.8 ± 4.2
97.8 ± 3.8
95.7 ± 5.3
98.6 ± 4.5
90.1 ± 4.4
95.2 ± 3.7
53.0 ± 3.7
98.5 ± 5.6
95.3 ± 3.9
96.3 ± 4.6
99.3 ± 5.1
96.8 ± 3.7
94.0 ± 3.5
83.9 ± 4.7
93.3 ± 4.6
96.6 ± 4.9
47.7 ± 5.1
96.1 ± 4.2
97.8 ± 4.4
94.7 ± 4.1
94.7 ± 5.6
96.4 ± 5.1
92.7 ± 4.7
Azinphos-Et
Azinphos-Me
Bromophos
Bromophos-Et
Cadusafos
Carbophenothion
Chlorfenvinphos
Chlorpyrifos-Et
Chlorpyrifos-Me
Coumaphos
<0.01
<0.01
0.26
0.36
0.30
0.15
0.05
0.25
0.13
0.01
DDVP
Demeton-S-methyl
sulfone
Diazinon
Diazoxon
Dichlofenthion
Dimethoate
Dioxathion
Disulfoton
Ethion
Ethoprophos
Etrimfos
Fenamiphos
Fenchlorphos
Fenitrothion
Fenthion
Fenthoate
Fonofos
Formothion
Heptenophos
Isofenphos
Malathion
Methacrifos
Methidathion
Parathion-Et
0.04
<0.01
0.20
0.49
0.12
0.15
0.21
0.15
0.21
0.10
0.15
0.11
0.60
0.24
0.41
0.24
0.06
0.26
<0.01
<0.01
0.15
0.11
0.17
0.16
0.03
0.19
0.02
0.06
0.06
0.16
<0.01
0.04
0.08
0.03
0.04
<0.01
0.03
0.11
0.10
0.10
0.10
0.16
0.16
0.09
0.15
0.19
0.34
0.19
0.24
0.12
0.15
0.10
0.28
0.10
0.11
0.19
0.12
0.26
0.18
0.53
0.38
0.39
0.40
0.80
0.62
0.45
0.76
0.95
1.71
0.73
0.93
0.47
0.76
0.38
1.36
0.38
0.55
0.93
0.60
0.99
0.69
Parathion-Me
Phosalone
Phosphamidon (E + Z)
Pirimiphos-Me
Pyrazophos
Pyridafenthion
Sulfotep
<0.01
0.02
<0.01
0.16
0.04
0.01
0.08
0.10
0.31
0.39
0.10
0.31
0.33
0.09
0.38
1.52
1.54
0.38
1.52
1.67
0.44
Lb
81.5 ± 3.2
53.7 ± 3.4
68.2 ± 3.8
81.9 ± 3.4
92.3 ± 4.2
88.1 ± 6.3
96.5 ± 3.3
Hc
92.9 ± 4.8
91.3 ± 4.8
91.5 ± 4.8
96.7 ± 6.0
98.9 ± 4.4
99.4 ± 5.8
94.4 ± 4.5
(continued)
Determination of OP Pesticide Residues in Vegetable Oils
269
Table 1 (continued)
Mean (N = 6) Recovery Values of 45 Organophosphorus Pesticides From 1 g Olive Oil Spiked at
Two Different Levels (ISO Names Used)
Spiking level
(mg/kg)
p-valuea
Pesticide
Tetrachlorvinphos
Tolclofos-Me
Triazophos
Trithion
0.03
0.12
<0.01
0.17
Lb
Hc
0.27
0.17
0.32
0.15
1.33
0.83
1.29
0.76
Recovery (%),
mean (N = 6) ± SD
Lb
95.7 ± 3.8
97.4 ± 3.6
75.5 ± 4.8
106.0 ± 4.9
Hc
96.1 ± 3.6
98.2 ± 4.2
101.6 ± 4.6
95.5 ± 4.7
a p value between n-hexane and acetonitrile by GC/FPD-P after a single distribution (p-value is the
fraction of solute partitioning into the nonpolar phase of an equivolume two-phase system).
bL is the lower spiking level, range 0.09–0.60 mg/kg.
cH is the higher spiking level, range 0.38–2.35 mg/kg.
SD, standard deviation.
The sample spiked at about 0.1 mg/kg is used as the quality control sample for routine
recovery check with each batch of analyses. The quantitation of the spiked samples is
carried out using a matrix-matched calibrant solution.
3.6. Performance of the Method
Typical recovery values and standard deviation for 45 OP pesticides are reported in
Table 1 (see Note 7) in the lower (0.09–0.60 mg/kg) and higher (0.38–2.35 mg/kg)
ranges of concentration.
In the lower concentration range tested, satisfactory (70–110%) results (74–86%)
were obtained for 39 OP pesticides, but not for formothion (5%), disulfoton (32%)
phosalone (54%), demeton-S-methyl sulfone (60%), fenthion (62%), and
phosphamidone (which was borderline at 68%). In the higher concentration range
tested, satisfactory results (82–103%) are obtained for all OP pesticides except
formothion (48%) and disulfoton (53%).
4. Notes
1. Because the nominal volume of the Extrelut NT-3 cartridge is 3 mL, no solvent is expected
to drain from the cartridge at this stage.
2. The flow rate is dropwise and is self-regulated by the pressure drop through the cartridge
system.
3. Sometimes, the air bubble at the end of the Extrelut NT-3 cartridge or in the glass connector between the silica and C18 cartridges can block the elution. To start the elution, temporarily apply, as far it is needed, slight pressure to the top of the Extrelut NT-3 cartridge
by a syringe connected to an “inverted” stopcock (see Fig. 1). When removing the syringe, slide the stopcock off to avoid sucking back the eluting solvent. Although the flow
rate is not critical regarding extraction efficiency, avoid increasing the flow rate too much.
4. Because traces of pesticides can be lost during concentration of the solution, the distillation temperature is lowered by adding methanol prior to concentration to form an azeotrope with acetonitrile. Avoid bringing the solution to complete dryness with the rotatory
270
Di Muccio et al.
evaporator. Instead, stop the concentration when a few drops of solvent are left. Then,
remove the flask from the evaporator and bring to dryness by manually rotating the flask
kept in an inclined position. The minute amount of lipid left after the cleanup acts as
“keeper,” that is, it helps reduce losses by volatilization.
5. Regarding the efficiency of the cleanup, the amount of the lipid matrix carried over into
the acetonitrile eluate mainly depends on the composition (triglycerides and minor components) of the fat analyzed. Solid fats such as pork fat are almost completely removed,
but highly unsaturated fish oils are less efficiently removed, and a further cleanup, for
instance, by high-performance size-exclusion chromatography (3–7), should be given.
6. Matrix effect in analytical chemistry is defined as the combined effect of all components
of the sample other than the analyte on the measurement of the quantity. If a specific
component can be identified as causing an effect, then it is referred to as interference.
Interferences can most likely produce effects at the detector level by enhancing or quenching the response for the analyte. For instance, matrix components not removed by the
cleanup step and eluting from the GC column at the same time as an OP pesticide may
influence its quantitation by FPD-P. Indeed, combustion in the detector flame produce
CO2, which absorbs part of the radiation emitted by the OP pesticide, quenching the
response of the detector. Instead, the bulk of matrix components can produce a matrix
effect at the injector level. Depending on the type, geometry, and operating conditions of
the injector, labile compounds, including certain OP pesticides, can undergo partial degradation in the injector. The coextractives injected generally have a protective action on
the analyte, so the proportion of the injected amount of the analyte transferred to the GC
column (and hence detected) is influenced by the amount of the coextractives injected
together with the analyte. Consequently, the matrix effect results in enhancement of the
signal in a sample extract compared to the signal for a solvent-based calibration standard
of the same concentration. In these cases, the calculated concentration of an affected
pesticide in the sample is higher than the true concentration. The entity of this matrix
effect depends on the pesticide, concentration, matrix components, and condition of the
GC system. The most common approach to counteract this matrix enhancement effect is
the use of matrix-matched standards, that is, calibration standards in blank sample extracts (13,14). To prepare a matrix-matched calibrant solution, process a blank sample
with the described method to obtain the final blank extract. Redissolve with the working
standard solution and use as calibrant solution. The operator should check under the instrument and operating conditions if a relevant matrix effect occurs with the analyte(s) of
interest.
7. The ability of the method to recover compounds of different polarity through the oncolumn partition step can be predicted by calculating the p value (15,16), defined as the
fraction of solute partitioning into the nonpolar phase of an equivolume two-phase system. The lower the p value, the more efficiently the polar compounds are partitioned into
the acetonitrile eluate. The 45 OP pesticides tested have p values between n-hexane and
acetonitrile in the range <0.01–0.36, indicating the ability of the method to recover compounds with a wide range of polarity.
References
1. McMahon, B. M., and Hardin, N. F. (eds.). (1994) Pesticide Analytical Manual, US Department of Health and Human Services, Food and Drug Administration, Washington,
DC, Volume I, Section 304, pp. 15–17.
Determination of OP Pesticide Residues in Vegetable Oils
271
2. Parfitt, C. H. (ed.). (2000) Pesticide and industrial chemical residues, in Official Methods
of Analysis of AOAC International, 7th ed. (Horwitz, W., ed.), AOAC International,
Gaithersburg, MD, pp. 6–7.
3. Blaha, J. J. and Jackson, P. (1985) Multiresidue method for quantitative determination of
organophosphorus pesticides in foods. J Assoc. Off. Anal. Chem. 68, 1095–1099.
4. Specht, W. and Tilkes, M. (1985) Gas-chromatographische Bestimmung von Rückständen
an Pflanzebehandlungsmitteln nach Clean-up über Gel-Chromatographie und Mini-KieselSäulen-Chromatografie. Fresenius Z. Anal. Chem. 322, 443–455.
5. Roos, A. H., van Munsteren, A. J., Nab, F. M., and Tuinstra, L. G. M. Th. (1987) Universal extraction/clean-up procedure for screening of pesticides by extraction with ethyl acetate and size exclusion chromatography. Anal. Chim. Acta 196, 95–102.
6. Seymour, M. P., Jefferies, T. M., and Notarianni, L. J. (1986) Large-scale separation of
lipids from organochlorine pesticides and polychlorinated biphenyls using a polimeric
high-performance liquid chromatographic column. Analyst 111, 1203–1205.
7. McMahon, B. M. and Hardin, N. F. (eds.). (1994) Pesticide Analytical Manual, 3rd ed.,
US Department of Health and Human Services, Food and Drug Administration, Washington, DC, Vol. 1, Section 304, pp. 21–24.
8. Di Muccio, A., Pelosi, P., Attard Barbini, D., et al. (1999) Determination of pyrethroid
pesticide residues in fatty materials by solid-matrix dispersion partition followed by minicolumn size-exclusion chromatography. J. Chromatogr. A 833, 19–34.
9. Di Muccio, A., Pelosi, P., Attard Barbini, D., Generali, T., Ausili, A., and Vergori, F.
(1997) Selective extraction of pyrethroid pesticide residues from milk by solid-matrix
dispersion. J. Chromatogr. A 765, 51–60.
10. Di Muccio, A., Ausili, A., Vergori, L., Camoni, I., Dommarco, R., and Gambetti, L. (1990)
Single-step multi-cartridge clean up for organophosphate pesticide residue determination
in vegetable oil extracts by gas chromatography. Analyst 115, 1167–1169.
11. Di Muccio, A., Generali, T., Attard Barbini, D., et al. (1997) Single-step separation of
organochlorinated pesticide residues from fatty material by combined use of solid-matrix
partition and C18 cartridges. J. Chromatogr. A 765, 61–68.
12. Di Muccio, A., Pelosi, P., Attard Barbini, D., et al. (2002) Application of single step, solid
matrix partition-C18 cleanup to the analysis of N-methylcarbamate residues in fats and
oils, in Abstract Book Fourth European Pesticide Residues Workshop (EPRW 2002),
Rome, Italy, May 28–31, Poster 143.
13. Schenck, F. J. and Lehotay, S. J. (2000) Does further clean-up reduce the matrix enhancement effect in gas chromatographic analysis of pesticide residues in food? J. Chromatogr.
A 868, 51–61.
14. Hajslová, J. and Zrostlíková, J. (2003) Matrix effects in (ultra)trace analysis of pesticide
residues in food and biotic matrices. J. Chromatogr. A 1000, 181–197.
15. Bowman, M. C. and Beroza, M. (1965) Extraction p-values of pesticides and related compounds in six binary solvent systems. J. Assoc. Off. Anal. Chem. 48, 943–965.
16. Beroza, M., Inscoe, M. N., and Bowman, M. C. (1969) Distribution of pesticides in immiscible binary solvent systems for cleanup and identification and its application in the
extraction of pesticides from milk. Residue Rev. 30, 1–61.
Pesticide Analysis by LPGC–MS/MS
273
21
Multiclass Pesticide Analysis in Vegetables
Using Low-Pressure Gas Chromatography
Linked to Tandem Mass Spectrometry
Francisco J. Arrebola Liébanas, Francisco J. Egea González,
and Manuel J. González Rodríguez
Summary
A method for determining pesticide residues in vegetables by low-pressure gas chromatography–tandem mass spectrometry (LPGC–MS/MS) is proposed after a fast and
simple extraction of the vegetable with dichloromethane and without cleanup steps. The
technique reduces the total time required to determine 72 pesticides to less than 31 min,
increasing the capability of a monitoring routine laboratory with respect to conventional
capillary GC. The use of a guard column and a carbofrit plug into the glass liner in
combination with LPGC avoids previous cleanup steps, simplifying the manipulation of
the sample and reducing time, cost, and uncertainty of the final result. The method presents limits of quantitation (LOQs) low enough to determine the pesticide residues at
concentrations below the maximum residue levels stated by legislation.
Key Words: Fast gas chromatography; low-pressure gas chromatography; pesticides;
tandem MS; vegetables.
1. Introduction
The monitoring of pesticide residues in fruits and vegetables became a priority
problem because of the large list of active ingredients and large amounts applied
throughout the world. Several factors favor the application of pesticides to minimize
the incidence of pests and diseases caused by climatic conditions, crop cycles, or agronomic aspects such as high plants density or excessive use of fertilizers.
Pesticide levels are lower in agricultural commodities now because of the application of good farming practices. However, one must be completely certain that the residues are below the maximum residue levels (MRLs) established by governments or
regulatory bodies to minimize their consumer intake.
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
273
274
Arrebola Liébanas, Egea González, and González Rodríguez
The need is evident for programs for monitoring pesticide residues in fresh products to ensure compliance with MRLs (1) and to estimate better the actual exposure of
consumers to pesticide residues. Because of the trace detection levels required and the
complex matrices in which the target analytes have to be determined, efficient sample
preparation, detection at very low levels, and unambiguous identification are essential
steps in analytical methodology development. Probably two of the most important
features of an analytical method are the degree of selectivity and the detection limit.
Gas chromatography (GC)–tandem mass spectrometry (MS/MS) using benchtop
ion trap systems has been a relevant approach in pesticide residue analysis, allowing
both increased selectivity and decreased detection limits (2,3). However, a main goal
in the development of new GC–MS methods is the increase of analysis speed to reduce
the analysis time because the multiresidue methods currently used in pesticide residue
laboratories are relatively slow, restricting the number of analyses per day.
An approach to perform very fast separations, as Gidding first demonstrated (4), is
to conduct GC at subambient pressure conditions, that is, by creating a high vacuum in
the analytical column, what is called low-pressure gas chromatography (LPGC) (4–8).
This is achieved by coupling a wide-bore capillary column (0.53 mm id) to a restriction capillary that is positioned at the injector part. As a consequence, the optimal
linear gas velocity for capillary columns operated under vacuum can be increased by a
factor of 10. These high velocities result in very short analysis times compared to
conventional GC. The application of LPGC provides large sample capacity and originates chromatographic signals with similar peak widths as in traditional GC methods.
The last feature allows the use of a common scanning mass spectrometer (ion trap or
quadrupole) to obtain enough points for building the signals. In addition, LPGC provides a high signal-to-noise ratio because of the increased peak heights obtained at the
high gas velocities, improving detection limits. Another benefit is the low column
temperatures, which provide the possibility of analyzing thermolabile compounds at
trace levels as bleed will also be low owing to elution temperatures. A drawback of
this approach is a loss only in separation efficiency because of the use of shorter columns (10 m). The use of MS detection does not need complete chromatographic resolution between all compounds for analysis (9,10).
The present method is based on simple and fast solvent extraction of the vegetables
without postextraction cleanup steps before analysis. After that, an LPGC–MS/MS
determination is proposed for analyzing 72 multiclass pesticides in fresh vegetables in
an instrumental step of less than 31 min (a reduction of more than 50% with respect to
an alternative method based on conventional capillary GC).
2. Materials
2.1. Reagents
1. Pesticide standards with purity certified higher than 99% (e.g., Riedel-de-Haën, SeelzeHannover, Germany).
2. Caffeine used as internal standard (ISTD) with purity certified (e.g., Riedel-de-Haën).
3. Pesticide-quality solvents n-hexane, dichloromethane, methanol, and acetone.
4. Residue analysis-quality anhydrous sodium sulfate.
Pesticide Analysis by LPGC–MS/MS
275
2.2. Stock and Working Standard Solutions
1. Stock standard solutions (between 75 and 550 µg/mL must be prepared by exact weighing and dissolution in acetone and stored in a freezer at −30°C without exposure to light
(see Note 1).
2. Working standard solutions (5 µg/mL) are prepared by appropriate dilution of the stock
standard solutions with cyclohexane and stored in a refrigerator (4°C) (see Note 2).
2.3. Apparatus
1. Gas chromatograph with an ion trap tandem mass spectrometry detector (e.g., Varian
Instruments, Sunnyvale, CA). It must be fitted with electronic flow control, an
autosampler with a 100-µL syringe and a temperature-programmable injector.
2. Glass liner equipped with a carbofrit plug (e.g., Resteck Corp., Bellefonte, PA) (see Note 3).
3. Guard column consisting of a fused silica-untreated capillary column 2 m × 0.25 mm id
(e.g., Supelco, Bellefonte, PA) (see Note 4).
4. Wall-coated, open tubular, fused-silica column reference CP-Sil 8 CB with low bleed of
10 m × 0.53 mm id × 0.25-µm film thickness (e.g., Varian Instruments).
5. Helium (at least 99.999% pure).
6. Chopper.
7. Homogenizer (e.g., Polytron PT2100; Kinematica A.G., Littan/Luzern, Switzerland).
8. Rotary evaporator.
3. Methods
The method described outlines (1) the pesticide extraction procedure from vegetables, (2) the instrumental determination, and (3) the identification and quantification of the pesticide residues.
3.1. Pesticide Extraction From Vegetables
1. Chop and homogenize 2 kg vegetable sample (see Note 5).
2. Weight exactly a 15-g aliquot into a glass and mix with 50 mL of the dichloromethane in
the Polytron for 2 min.
3. Add 50 g anhydrous sodium sulfate and mix with the Polytron for 1 min.
4. Allow the mixture to rest for 2 min and then filter through a 9-cm Büchner funnel and
filter again through a paper filter with anhydrous sodium sulfate.
5. Evaporate the solvents to dryness in a rotary evaporator (35–40°C).
6. Redissolve the dried residue with 5 mL cyclohexane.
7. Add 1 mL of this solution to a 2-mL volumetric flask containing 50 µL of ISTD solution
of 20 mg/L and reach the final 2-ml volume with cyclohexane.
3.2. Instrumental Determination
1. Inject aliquots of 10 µL of sample into the gas chromatograph operating at a syringe
injection flow rate of 10 µL/s.
2. Hold the initial injector temperature at 70°C for 0.5 min and then increase at 100°C/min
to 310°C, which is held for 10 min (see Note 6). Hold the column temperature at 70°C for
3.5 min, increase at 50°C/min to 150°C, and then at 3°C/min to 235°C, and finally increase to 300°C at 50°C/min and hold for 3 min (see Notes 7 and 8).
3. Operate the ion trap mass spectrometer in MS/MS with electron impact (EI) (see Note 9).
4. Set the transfer line, manifold, and trap temperatures at 280, 50, and 200°C, respectively.
276
Arrebola Liébanas, Egea González, and González Rodríguez
5. Perform the analysis with a filament-multiplier delay of 4.75 min to prevent instrument
damage.
6. Activate the automatic gain control (AGC) with an AGC target of 5000 counts (see Note 10).
7. Set the emission current for the ionization filament at 80 µA, generating electrons with
70-eV energy, and set the axial modulation amplitude 4.0 V.
8. Carry out the MS/MS process by collision-induced dissociation (CID) with a nonresonant
excitation for all the compounds studied.
9. Set the electron multiplier voltage at 1700 V (+200 V offset above the autotuning process).
10. Scan rate and mass range scanned depend on the number of pesticides analyzed simultaneously (see Note 11). Typical parameters found using the described experimental conditions are shown in Table 1.
3.3. Identification and Quantification
1. Calculate the retention time window (RTW) for each pesticide like the retention time
average plus or minus three standard deviations of retention time when 10 blank samples
spiked at the second calibration level of each compound are analyzed.
2. Compare the retention time obtained in the analyzed sample with the RTW as identification criterion.
3. Confirm a previously identified compound by comparing the MS/MS spectrum obtained in
the sample with another stored as a reference spectrum in the same experimental conditions.
4. Obtain the reference spectra daily by injecting a blank cucumber sample spiked at the
concentration of the second calibration point (see Note 12). Figure 1 shows a fragment of
a gas chromatogram obtained in the selected experimental conditions monitoring the
quantification ion of each pesticide.
5. Build a calibration line, using at least three calibration points prepared into blank matrix
extract (see Notes 13 and 14), by plotting peak areas related to the ISTD against concentration of pesticide in milligrams per kilogram.
6. Calculate the amount of pesticide in the sample in milligrams per kilogram from the calibration curve.
7. Use as quality control criteria the analyses of a blank extract, a calibration set, and a blank
extract spiked with a known amount of the pesticides (see Note 15).
4. Notes
1. Some pesticides are light sensitive. They can be stored for at least 1 yr in the established
conditions.
2. They can be stored for at least 2 mo.
3. The size of the carbofrit plug must be adapted to the inner diameter of the glass liner. For
that, over a clean surface, the carbofrit must be softly rolled by pushing with the finger.
The reduction of the carbofrit size must be until just the internal glass liner diameter to
avoid plug movement during instrumental operation.
4. The use of a guard column together with the carbofrit plug reduces considerably the frequency of maintenance operations over the analytical column.
5. No degradation of the pesticides was detected in samples stored at 4°C for 24 h.
6. Several injection techniques are available with LPGC because, despite the fact that the
analytical column has to be kept under low-pressure conditions, the injector works at
conventional column head pressures. As a consequence, typical injection volumes can be
used, and the sample capacity is not limited. The amount injected (10 µL) allows the
determination of pesticide residues at concentrations below or equal to the MRLs with a
Pesticide Analysis by LPGC–MS/MS
7.
8.
9.
10.
11.
12.
277
good peak shape. Typical LOQs obtained for the studied compounds using similar instrumentation ranged from 0.2 to 22 µg/kg. The injector temperature is increased from 70 to
310°C to minimize breakdown of the most thermolabile pesticides.
Electronic flow control of the carrier gas is recommended to optimize separation of the
target analytes when a GC analysis with LPGC columns is performed as well as with
ovens with temperatures that can be programmed to provide fast heating rates and highfrequency digital output detection.
In general, LPGC columns show lower separation efficiency than conventional capillary
columns in the analysis of complex compound mixtures. The lack of selectivity in the
analysis of complex pesticide mixture is compensated by using the MS/MS detector,
which allows essentially error-free identification of the compounds if the optimization of
the MS/MS parameters is properly adjusted.
Ion trap detectors that carry out the ionization inside the trap chamber can quickly switch
between chemical ionization and EI modes along the same run. This allows optimization
of the ionization step for each pesticide. However, because of the high number of pesticides frequently analyzed, sometimes it is necessary compromise when various chemical
ionization and EI pesticides coelute.
The AGC continuously adapts in an automatic mode the ionization time of the ion trap
detector to avoid a reduction of the sensitivity. For the optimization of detector sensitivity, the trap should be filled with the target ions. A higher AGC target would cause electrostatic interactions between the ions (space–charge effects), providing degraded
performance.
MS/MS detection mode can apply different CID conditions that switch quickly. Each
CID condition is specific for each coeluted analyte. After acquisition, the plotting of the
experimental data obtained separately for each pesticide offers a selective chromatogram
for each compound. Nevertheless, the capability of the detector to analyze a large number
of coeluting analytes is limited. With a constant mass spectrometer scanning speed (for
the Saturn 2000, it is 5600 thomson/s), the scan time for a MS/MS experiment depends,
among other things, on the m/z range scanned and the number of microscans acquired to
obtain an averaged spectrum of adequate signal-to-noise ratio. The lack of optimization
of these parameters may generate chromatographic peaks defined by too few points or by
enough points obtained with an elevated uncertainty; that is, it can affect the precision of
the chromatographic data. For this reason, the parameters mentioned above have been
extensively studied for the pesticides that coelute to obtain good-quality spectra and peak
shapes. The m/z range scanned is adjusted for each pesticide to cover only the product
ions obtained under the MS/MS conditions selected. In the case of MS/MS spectra with
several not-very-intense qualifier ions, some of these ions are discarded and not scanned
to shorten in the scan time. Figure 2 represents the influence of m/z range scanned on the
total scan time. The number of microscans averaged to obtain a spectrum is relevant in
the peak shape and spectral fit. Typical chromatographic peak shapes obtained are shown
in Fig. 3. Acceptable peak shapes are obtained for two and three microscan cases, but
appreciably worse results are generated when one microscan is selected (some intensity
points can decrease or increase abnormally). This shows that the process of spectral averaging improves the precision of the total intensity of the spectrum, and that at least two
microscans should be obtained to average the final spectrum.
For some pesticides, small differences have been observed between spectra obtained with
and without matrix influence. The comparison results (fit) are scaled to 1000 for the best
match (identical spectra). To set the fit threshold for each pesticide, the average fits of the
278
Arrebola Liébanas, Egea González, and González Rodríguez
Table 1
GC–MS/MS Conditions (see Note 16)
Pesticide
Dichlorvos
Acephate
Heptenophos
Propoxur
Ethoprophos
Dimethoate
Lindane
Pyremethanil
Chlorthalonil
Disulfoton
Etrimphos
Pirimicarb
Caffeine
Formothion
Ethiofencarb
Chlorpirifos-m
Vinclozoline
Parathion-m
Metalaxyl
Pirimiphos-m
Fenitrotion
Malathion
Chlorpyrifos
Fenthion
Triadimefon
Tetraconazole
Dicofol
Pendimethalin
Penconazole
Chlozolinate
Isonfenphos
Pyrifenox
Chlorfenvinphos
Procymidone
Quinometionathe
Endosulfan I
Fenaminphos
Fludioxinil
Buprofezin
Hexaconazole
Bupimirate
Endosulfan II
Parent ion
(m/z)
CID
Amplitude
(V)
CID
Rf
(m/z)
Quantification
ion
(m/z)
185
136
124
152
158
125
219
198
266
186
292
166
194
170
168
286
285
263
206
290
260
173
314
278
208
336
250
252
248
331
213
263
267
283
234
241
303
248
249
231
273
241
78
37
37
41
27
55
70
100
90
60
45
49
56
38
39
72
34
48
54
64
65
51
100
92
62
96
49
62
77
88
52
90
82
57
60
84
56
84
50
100
77
84
81
47
47
66
47
60
100
81
85
71
70
53
60
70
63
85
100
80
75
85
71
75
170
112
75
108
90
95
89
145
93
100
100
80
83
80
95
89
80
100
120
80
109 + 131
107 + 119
89
110
94 + 114 + 130
79
180 + 183
98
133
97
181
83
120
107
107
208
241 + 213
136 + 216
132 + 162
151
122 + 138 + 170
99
258
135
144
218
215
208 + 191 + 162
192 + 157
259
185
192 + 228
159
253:257
196
170 + 172
195
152 + 154 + 127
191:195
159
193
170 + 172
Range
(m/z)
80–190
80–190
80–160
80–160
70–230
70–230
140–220
90–300
90–300
90–300
90–300
80–200
80–200
80–200
80–200
100–300
100–300
100–300
100–300
90–300
90–300
90–320
90–320
90–320
90–345
90–345
90–345
90–345
90–300
90–300
90–300
90–300
90–300
90–300
69–250
69–250
120–305
120–305
120–305
120–275
120–275
120–275
(continued)
Pesticide Analysis by LPGC–MS/MS
279
Table 1 (Continued)
GC–MS/MS Conditions (see Note 16)
Pesticide
Oxadixyl
Ethion
Benalaxyl
Carbofenothion
Endosulfan III
Propiconazole
Nuarimol
Tebuconazole
Propargite
Iprodione
Bromopropylate
Bifenthrin
Fenpropathrin
Tetradifon
Furathiocarb
Phosalone
Piriproxifen
Cyhalothrin
Amitraz
Pirazofos
Acrinathrin
Permethrin
Pyridaben
Cyfluthrin
Cypermethrin
Flucythrinate
Esfenvalerate
Difenoconazole
Deltramethrin
Azoxistrobina
Parent ion
(m/z)
CID
Amplitude
(V)
CID
Rf
(m/z)
Quantification
ion
(m/z)
Range
(m/z)
163
231
148
342
272
259
235
250
173
314
341
181
265
229
325
182
136
181
162
265
181
183
147
206
163
157
225
323
253
345
46
63
46
64
64
78
56
63
56
88
45
40
72
95
77
70
57
90
50
87
87
74
53
96
53
69
51
87
57
92
71
100
50
131
80
114
75
75
66
125
70
50
95
100
140
80
59
80
71
120
80
70
64
86
70
79
70
122
90
115
132
175 + 203
91
199 + 157
235 + 238
191 + 173
139
125
117 + 145
245 + 271
181:187
165
210
197:203
194
111 + 138
96
152
132 + 147
210
152
152
111 + 105
149:152
127
107
119
265
172 + 174
329
100–235
100–235
90–345
90–345
90–345
100–260
100–260
100–260
100–260
140–345
140–345
140–275
140–275
140–275
100–330
100–330
70–140
120–290
120–290
120–290
70–200
70–200
70–200
100–325
100–325
100–325
100–325
100–325
120–350
120–350
MS/MS spectra from 10 injections of the midlevel standard are determined, and 250 units
are subtracted from the average. It often can be automatically carried out by the instrument software if the signal-to-noise ratio of the chromatographic peak is above 3. Typical
confirmation threshold fits are obtained between 500 and 725.
13. More calibration points would increase the fit of the calibration function to the experimental data but reduce the total number of real samples analyzable in routine laboratories. It has been observed that three calibration levels can be considered appropriate for
quantifying all the pesticides included in the method. The concentration level for each
calibration point should be stated considering the MRL regulated for each pesticide and
food commodity. For all compounds, the first point of the calibration curve is set at a
concentration between LOQ and the smallest MRL found for the vegetables studied at
280
Arrebola Liébanas, Egea González, and González Rodríguez
Fig. 1. Extract of a gas chromatogram showing six of the studied pesticides. It includes the
product ion monitored for quantitation.
different legislations. In cases such as for acephate, when the LOQ is not much lower
than the minimum MRL, the first calibration point is the MRL. On the other hand, for all
pesticides, the highest calibration concentration is set to 15 times the first calibration
concentration. Therefore, the range of calibration must include the MRL stated. Typical
correlation coefficients between 0.98 and 0.99 can be obtained using instrumentation similar to the above described using linear calibration functions.
14. The origin can be added as a calibration point, but the calibration function should not be
forced through the origin. The fit of the calibration function must be plotted and inspected
visually, avoiding reliance on correlation coefficients, to ensure that the fit is satisfactory
in the region relevant to the residues detected. Extracts containing high-level residues
may be diluted to bring them within the calibrated range, adjusting accordingly the concentration of matrix extract. It is recommended to evaluate potential matrix effects at
method validation. Food commodities should be classified according to certain reference
matrices for calibration purposes. Such matrices must correspond at least to the next crop
groups: (1) cereals and other dry crops, (2) commodities with high water content, (3)
commodities with high fat content, and (4) fruits with high acid content. The validation
process must evidence the representativeness of such reference matrices used for calibration purposes. Analysis of spiked blank samples with the pesticides originates typical
recovery data between 71 and 108% with relative standard deviations always lower than 18%.
15. A proposal for quality control criteria is as follows:
For blank analysis, no signals should be detected in the RTWs of the target analytes.
Spiked sample should be spiked at the second calibration level, and the pesticides
should present routine recovery rates between 60 and 140% (70–110% when residue
levels higher than the MRLs have been determined).
Pesticide Analysis by LPGC–MS/MS
281
Fig. 2. Influence of m/z range on the scan time.
The calibration curve should present a coefficient of determination R2 higher than
0.95, and the individual points must not exceed more than ±20% (±10% when the
MRL is approached or exceeded) from the calibration curve in the relevant region.
Otherwise, a more satisfactory calibration function must be used, or the determinations must be repeated.
16. For the dissociation conditions, in general, the precursor ion isolated is selected with the
aim of achieving a compromise between both selectivity (the highest m/z ion) and sensitivity (the highest intensity ion). To achieve this, precursor ions are fragmented (CID)
with the goal of generating spectra with multiple fragment ions of relatively high intensity that permitted accurate quantification while preserving a certain proportion (10 and
20%) of the precursor ions. This objective can be achieved by appropriate selection of the
nonresonant excitation amplitude and excitation storage level. The excitation storage
level, which is related to the trapping field that stabilizes the parent ion, is selected as the
minimum value that allows the dissociation of the parent ion. If a higher excitation storage level is applied, the ions are held in the trapping field more strongly, allowing the
application of a higher excitation voltage, which is able to produce more product ions.
Nevertheless, if the excitation storage level is too high, the lower mass product ions will
not be trapped and will not be observed in the spectrum. The MS/MS spectra obtained
under the final experimental conditions are stored in a home-made MS/MS library.
Acknowledgments
We are grateful to Instituto Nacional de Investigación y Tecnología Agraria y
Alimentaria (INIA) (Project CAL03-055) and FIAPA (2000/01), Spain for financial support.
282
Arrebola Liébanas, Egea González, and González Rodríguez
Fig. 3. Influence of number of microscans used to obtain averaged spectra on GC peak
shape for pirimiphos methyl.
References
1. Community Directive 93/58 EEC, Off. Eur. Commun. L 211/6, European Community,
Brussels, 1993.
2. Martínez Vidal, J. L., Arrebola, F. J., and Mateu-Sánchez, M. (2002) Application to routine analysis of a method to determine multiclass pesticide residues in fresh vegetables by
gas chromatography/tandem mass spectrometry. Rapid Commun. Mass Spectrom. 16,
1106–1115.
3. Martínez Vidal, J. L., Arrebola, F. J., and Mateu-Sánchez, M. (2002) Application of gas
chromatography–tandem mass spectrometry to the analysis of pesticides in fruits and
vegetables. J. Chromatogr. A 959, 203–213.
4. Giddings, J. C. (1962) Theory of minimum time operation in gas chromatography. Anal.
Chem. 34, 314–319.
5. Van Deursen, M. M., Janssen, H. G., Beens, J., et al. (2000) Fast gas chromatography
using vacuum outlet conditions. J. Microcol. Sep. 12, 613–622.
Pesticide Analysis by LPGC–MS/MS
283
6. Amirav, A., Tzanami, N., Wainhaus, S. B., and Dagan, S. (1998) Megabore vs microbore
as the optimal column for fast gas chromatography/mass spectrometry. Eur. Mass
Spectrom. 4, 7–13.
7. De Zeeuw, J., Peene, J., Janssen, H.-G., and Lou, X. (2000) A simple way to speed up
separations by GC–MS using short 0.53 mm columns and vacuum outlet conditions. J.
High Resolut. Chromatogr. 23, 677–680.
8. Mastovská, K., Lehotay, S. J., and Hajslová, J. (2001) Optimization and evaluation of
low-pressure gas chromatography–mass spectrometry for the fast analysis of multiple
pesticide residues in a food commodity. J. Chromatogr. A 926, 291–308.
9. González Rodríguez, M. J., Garrido Frenich, A., Arrebola Liébanas, F. J., and Martínez
Vidal, J. L. (2002) Evaluation of low-pressure gas chromatography linked to ion-trap
tandem mass spectrometry for the fast trace analysis of multiclass pesticide residues.
Rapid Commun. Mass Spectrom. 16, 1216–1224.
10. Arrebola, F. J., Martínez Vidal, J. L., González-Rodríguez, M. J., Garrido-Frenich, A.,
and Sánchez Morito, N, (2003) Reduction of analysis time in gas chromatography—
application of low-pressure gas chromatography–tandem mass spectrometry to the determination of pesticide residues in vegetables. J. Chromatogr. A 1005, 131–141.
MSPD for Pesticides in Fish and Foods
285
22
Use of Matrix Solid-Phase Dispersion for Determining
Pesticides in Fish and Foods
Steven A. Barker
Summary
We describe here a method using matrix solid-phase dispersion (MSPD) for the analysis of atrazine, metribuzin, cyanazine, and simazine in fish muscle tissue with a minimal
amount of time and solvent consumed. A tissue sample is placed in a glass mortar containing a bonded-phase solid support material. The solid support and sample are manually blended together using a glass pestle. The blended material is packed into a column
containing activated Florisil and eluted with acetonitrile:methanol (9:1). The eluate is
concentrated and analyzed by high-performance liquid chromatography with ultraviolet
detection. The linearity of response ranges from 0.35 to 8.0 ppm, and the average percentage recoveries are between 75 ± 3 and 106 ± 4%, for a spiking level of 0.35 ppm. The
intraassay variability is <3%, and the interassay variability is <5%.
Key Words: Atrazine; cyanazine; fish; high performance liquid chromatography;
matrix solid-phase dispersion; metribuzin; MSPD; simazine; triazines.
1. Introduction
The most difficult biological samples to extract and subsequently analyze for pesticides are solids, semisolids, and highly viscous samples. A method first introduced in
1989 has greatly simplified this task and found extensive application for drug and
pesticide analysis of biological samples. In the years since its introduction, this method
has become a proven protocol for the isolation of a wide range of pesticides from a
variety of biological samples (1–52). The method is known as matrix solid-phase dispersion or MSPD (52).
The utility of MSPD in this regard has been based on the fact that the MSPD process simultaneously and efficiently accomplishes several steps in the more classical
approach to sample preparation and solid-phase extraction (SPE)/fractionation, is
somewhat generic, and eliminates many of the confounding properties of more classical extraction procedures. The application of MSPD to difficult analytical problems
has shown that it can greatly reduce analyst time, increase sample throughput and
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
285
286
Barker
shorten turnaround time, reduce solvent use and the attendant expense of solvent purchase and disposal, and eliminate emulsion formation seen in classical extractions
while providing analytical results equal to or better than classical or “official” methods.
Thus, a sample (tissue, fruit, etc.) is placed in a glass mortar containing a bondedphase solid support material, such as octadecylsilyl-derivatized silica (C18). The solid
support and sample are manually blended using a glass pestle. In this manner, the
irregularly shaped silica-based solid support serves as an abrasive that promotes disruption of the sample’s general architecture and acts as a bound solvent that appears to
further disrupt the sample by inducing lysis of cells and other cellular structures. Studies have shown that the sample is dispersed over the surface of the solid support material, greatly enhancing sample surface area available to extraction (24,25,47,52).
The blended material is packed into a column (or a co-column containing other
column packings) suitable for conducting sequential elution with solvents. The blended
sample components and their distribution in the bonded phase and support provide a
new phase that exhibits a unique character for performing sample fractionation.
We describe here the details of an MSPD method (23), having selected members of
the family of triazines, specifically atrazine [1912-24-9], metribuzin [21097-64-9],
cyanazine [21725-46-2], and simazine [122-34-9], to serve as models to define a complete process for the rapid extraction, detection, and analysis of compounds of concern
in the incidence of fish kills. Triazines are highly effective for pre- and postemergent
weed control but are often associated with unintentional fish kills from overspraying,
runoff, and improper disposal.
The multiresidue method detailed here is designed to detect lethal concentrations of
triazine pesticides in fish (usually parts per million) with a minimal amount of time and
solvent consumed and is adaptable to analysis of a variety of different classes of pesticides.
2. Materials
1. Liquid chromatographic (LC)-grade solvents from commercial sources: acetonitrile
(ACN), hexane, dichloromethane, water, and methanol.
2. 0.01 M Phosphate buffer, pH 6.0 (NaOH).
3. 0.45-µm Membrane filter (e.g., Metricel®, Gelman Sciences, Inc., Ann Arbor, MI).
4. Atrazine [1912-24-9], metribuzin [21097-64-9], cyanazine [21725-46-2], and simazine [12234-9] reference standards (99% purity; e.g., Crescent Chemical Co., Inc., Haupauge, NY).
5. Preparative-grade (bulk) C18 SPE material, 40-µm particle size, 18% carbon load, end
capped (e.g., Analytichem Bondesil™, Varian Associates, Harbor City, CA; see Note 1).
The C18 is cleaned prior to use by washing with two volumes each of hexane,
dichloromethane, and methanol. The material is then vacuum aspirated overnight to remove excess solvent. This material is stored at room temperature in a closed plastic container until used (see Note 2).
6. Pesticide residue (PR)-grade Florisil (e. g. Alltech Assoc., Inc., Deerfield, ILUSA), 60–
100 mesh [1343-88-0]. Activate by heating to 130°C for at least 1 wk before use. Activated Florisil is stored at 130°C in a solvent-washed, aluminum-foil-covered beaker.
7. Paper filters (1.5 cm, Whatman no. 1, Whatman, Florham Park, NJ).
8. 10-mL Disposable plastic syringe barrels and plungers (e.g., Becton Dickinson Co.,
Franklin Lakes, NJ) washed with hot soapy water, triple rinsed with tap water, doubledistilled water, and methanol. The syringe barrels and plungers are air dried prior to use.
MSPD for Pesticides in Fish and Foods
287
9. 1-mL Disposable plastic syringe barrels and plungers (e.g., Becton Dickinson Co.) are
washed with hot soapy water, triple rinsed with tap water, double distilled water, and
methanol. The syringe barrels and plungers are air dried prior to use.
10. Plastic 250-µL pipet tips.
11. Glass mortars and pestles (see Note 3).
12. 10-mL Disposable glass tubes.
13. Rubber bulb.
14. 1.5-mL Polypropylene test tube (e.g., MicroFuge, Sarstedt, Inc., Newton, NC).
15. 0.45-µm Syringe filters (e.g., Nalgene R, Rochester, NY).
16. LC autosampler vial (e.g., Hewlett-Packard, Wilmington, DE).
17. Narrow-bore column packed with octadecysilyl (ODS)-derivatized silica (200 × 2.1 mm,
ODS Hypersil, 5 µm; e.g., Hewlett-Packard, Wilmington, DE).
18. ODS guard column cartridge (20 × 2.1 µm, 5 µm; e.g., Hewlett-Packard).
19. 0.45-µm Membrane filter (e.g., FP Vericel™, Gelman Sciences, Inc.).
20. Centrifuge (e.g., Centra-M, International Equipment Co., Needham Heights, MA).
21. Software for LC control, data acquisition, and peak integration (e.g., Hewlett-Packard
ChemStation software).
3. Methods
The MSPD process is illustrated in Fig. 1A,B. The major steps involve column
preparation, sample dispersion onto a solid support material, analyte isolation, and
extract concentration, followed by analytical determination.
3.1. Preparation of Sample Extraction Columns
1. Tissue extraction columns are fashioned from 10-mL disposable plastic syringe barrels
washed with hot soapy water, triple rinsed with tap water, double-distilled water, and
methanol.
2. The syringe barrels and plungers are air dried prior to use.
3. Paper filters (two) are placed inside the base of the columns to serve as a frit.
4. Place 2 g of activated Florisil in the column.
5. A plastic pipet tip is secured to the outlet of the 10-mL barrels.
3.2. Extraction Procedure
1. In glass mortars containing 2.0 g of C18, place 0.5-g catfish fillet samples (see Note 4).
2. The samples are allowed to reach ambient temperature and, for standard curves, are injected with 40 µL of each triazine stock solution (concentrations of 4.37, 8.75, 25, 50, and
100 µg/mL) to achieve tissue concentrations of 0, 0.35, 0.7, 2, 4, and 8 µg/g, respectively.
Blanks (no tissue) and negative controls (tissue without analyte spiking) receive solvent only.
3. The samples are allowed to stand 5 min and then are blended using glass pestles (see Note 5).
4. The resulting mixture is transferred to a 10-mL column fitted with two 1.5-cm disk paper
filters and containing 2.0 g activated Florisil.
5. Another paper filter is placed on top of the transferred material and compressed to a
volume of approx 7.5 mL using a syringe plunger (see Note 6).
6. The column is placed in a rack over a clean 10-mL glass test tube.
7. Add 8 mL of a 9:1 ratio of ACN and MeOH (see Note 7).
8. The triazines are eluted over a 15- to 25-min period using gravity flow. Slight positive
pressure is applied to assist in initiating flow via a rubber bulb. The resulting eluent is
approx 5 mL (see Note 8).
288
Barker
9. The extract is placed in a water bath (35°C) and evaporated under nitrogen.
10. The eluent residue is reconstituted by the addition of 500 µL of mobile phase and
vortexed.
11. The sample extracts are placed in a 1.5-mL polypropylene test tube and centrifuged for 5
min at 15,600g.
12. The supernatant is placed in a previously cleaned 1-mL syringe fitted with a 0.45-µm
syringe filter, and the supernatant is passed into an LC autosampler vial.
Total extraction time is under 40 min.
3.3. LC Analysis
All high-performance liquid chromatographic (HPLC) analyses are performed using a liquid chromatograph with an autosampler. Data are acquired with a photodiode
array detector set at 220 nm with a 4-nm bandwidth and a reference signal at 450 nm
with an 80-nm bandwidth. Detector sensitivity is set at 20 mAU full scale.
A reversed-phase, narrow-bore, packed-silica column fitted with an ODS guard
column cartridge maintained at 40°C is used for all analyses.
MSPD for Pesticides in Fish and Foods
289
Fig. 1. (opposite page) (A) Preparation of the sample by MSPD; (B) preparation and elution
of the MSPD column.
290
Barker
The mobile phase composition is a 7:3 ratio of 0.01 M aqueous NaH2PO4 (pH 6.0)
(phosphate buffer) and ACN, respectively, delivered at a flow rate of 0.4 mL/min.
Mobile phase solvents are filtered over a 0.45-µm membrane filter. All solvents are
thoroughly purged with helium before use. A 10-µL aliquot of muscle extract is injected for LC analysis (see Note 9).
3.4. Identification and Quantification
Individual triazines are identified by their retention time relative (±1%) to reference standards and their ultraviolet diode array spectrum. Peak purity measurements
are also conducted to ensure the absence of coeluting interferences. Quantification of
the individual triazines is conducted using the relative peak height (or area) of the
detected peak to those observed from fortified samples plotted as a standard curve,
fitted to the linear regression line and equation for the line so derived (see Notes 9–14).
3.5. Data Analysis
The statistical parameters used to validate this method for triazine analysis include linearity of response, precision, and accuracy. Specificity and sensitivity are also evaluated.
1. Linearity of response: A standard curve covering the range of concentrations from 0.35 to
8 ppm for standards and extracts is made using the mean of the area of the replicate
samples (see Note 10).
2. Precision is evaluated by examining intraassay variability and interassay variability. The
values for the intraassay variation are derived from the coefficient of variation (CV) of
means plus or minus standard deviation (SD) of peak areas of three repetitions of analysis
of the same sample for each concentration. Overall intraassay variability of the method is
determined by averaging the CVs for the five concentrations (0.35–8 ppm) examined.
The values for the interassay variability are derived from the CV of peak areas of three
distinct samples extracted and assayed on three different days. Overall interassay variation (±SD) of the method is obtained by averaging the CV of each individual concentration (0.35–8 ppm; see Note 11).
3. Recovery is evaluated by dividing the average peak area of each concentration obtained
after extraction by the average peak area of the respective standard concentration obtained without extraction. The average percentage recovery P is calculated by summing
the recovery percentage for each sample concentration on each separate day and dividing
by three. The relative standard deviation of P is calculated by determining the standard
deviation of P and dividing by P (see Note 12).
4. Specificity is calculated as the percentage of true negative samples of the number of
known negatives tested (see Note 13).
5. Sensitivity is calculated as the percentage of correctly identified positive samples (true
positives) of the total number of known positives tested (see Note 14) within the limits of
the assay.
4. Notes
1. To date, silica-based support materials have been the most frequently used for MSPD.
The use and effect of synthetic polymer-based solid supports is a subject for further study,
particularly supports that possess unique surface and pore chemistries, such as hydrophobic interaction supports. For silica-based materials, however, studies have shown that the
pore size is of minor importance in MSPD. This effect could vary with the sample and
MSPD for Pesticides in Fish and Foods
2.
3.
4.
5.
291
should be considered, however. The effect of average particle size diameter has also been
examined. As may well be expected, the use of very small particle sizes (3–10 µm) leads
to extended solvent elution times for a MSPD column, requiring excessive pressures to
obtain adequate flow. However, 40-µm particle size materials (60-Å average pore diameter) have been used most frequently and quite successfully. It has been reported that a
blend of silicas possessing a range of particle sizes (40–100 µm) also works quite well,
and such materials also tend to be less expensive. Depending on the application, non-endcapped materials or materials having a range of carbon loading (8–18%) may also be
used. It is a simple matter to examine these variables for a given application and should
be considered for obtaining the best extraction efficiency and the cleanest sample. The
bonded phase will, of course, play a pivotal role. Depending on the polarity of the phase
chosen, rather dramatic effects on the results may be observed, and a range of available
phases should be examined for each application. It has been reported that, in applications
requiring a lipophilic bonded phase, C18 and C8 can be used interchangeably. In general,
it has been observed that the isolation of more polar analytes from biological samples is
assisted by the use of polar phases (e.g., cyanopropyl) and less-polar analytes by lesspolar phases. This would be expected based on retention characteristics of compounds
discerned from classical SPE (24,25,47,52).
Preconditioning of the materials used for MSPD greatly enhances analyte recovery, as
has been established with SPE. However, in MSPD it also appears to speed the process of
sample blending and dispersal by breaking the surface tension differences that may exist
between the sample and bonded-phase solid support. As with SPE, washing or rinsing the
solid support materials prior to use also eliminates contaminants from the final eluates
obtained for analysis.
Glass or agate mortars and pestles are preferred. Porcelain mortars and pestles have been
observed to cause loss of analyte and cross-contamination to subsequent samples, perhaps because of the more porous nature of this material.
It is important that the sample used is truly representative. Homogeneity issues can be
reconciled by previous homogenization of a larger sample. Taking 0.5-g subsamples of
the homogenate for MSPD analysis is simply a smaller scale version of the more classical
approach to the problem. The best ratio of sample-to-bonded-phase solid support material
is 1 to 4. Most applications have employed lipophilic bonded phase (C18) materials,
blending 2.0 g solid support with 0.5 g sample. The best ratio, of course, is dependent on
the application and should be examined as a variable during method development. Ratios
of bonded phase solid support to sample less than 4:1 have been used successfully, and
samples have been scaled up to 2 g from the typical 0.5 g used in most MSPD procedures,
blended with a proportionately greater amount of solid support (24,25,47,52).
The process of blending requires only moderate pressure to produce sample dispersion
onto the solid support surface. It is not necessary, and is perhaps deleterious, to use excessive force, “grinding” the sample and solid support into the mortar surface. The blending
process does not require vigorous effort to accomplish but is dependent on the degree of
connective tissue or other more rigid biopolymer content of the sample. Different analysts may apply differing amounts of pressure or attain different degrees of dispersion of
the sample. This may be reflected in different levels of recovery in analyst-to-analyst
comparisons during method validation studies. However, excellent agreement is still usually attained in the final result, with good overall accuracy and precision and low variability. It should be kept in mind that in MSPD the sample itself is dispersed throughout the
column. In contrast, much of the sample is retained only in the first few millimeters of the
column bed in SPE. In MSPD, the sample matrix components cover much of the bonded-
292
6.
7.
8.
9.
10.
Barker
phase solid support surface, creating a new phase that is dependent on the interactions
with the solid support and bonded phase, interactions that give the MSPD column its
unique character. This new phase, in association with the analyte’s distribution and own
interactions with it, are perhaps the most important controlling factors in elution vs retention (24,25,47,52).
The column should be loosely packed, keeping in mind the basic principles of chromatography, avoiding voids or channels. Tightly compressing the column causes the elution
flow rate to be greatly diminished.
The correct choice of elution solvents and the sequence of their application to a column
are of utmost importance to the success of MSPD or SPE fractionation of samples. Elution solvent sequence and composition can be varied to obtain the best analytical results,
attempting to isolate the analyte or further clean the column of interfering substances
with each solvent step. The use of co-columns, such as the Florisil used here, is also
available to enhance sample cleanup. The nature of MSPD columns and the enhanced
degree of interaction with matrix components permit isolation of different polarity
analytes or entire chemical classes of compounds in a single solvent or in differing polarity solvents passed through the column. This characteristic makes MSPD amenable to
conducting multiresidue isolation and analysis on a single sample. In this regard, true
gradient elution of a MSPD column has not been reported to date but should nonetheless
prove applicable to the complete fractionation of samples for a range of pesticides. It has
been observed that, in an 8-mL elution of a 2-g C18 column blended with 0.5 g sample,
that most of the target analytes elute in the first 4 mL or in approx 1 column volume. This
will of course vary with each application and with appropriate solvent selection but should
be examined to reduce the use of solvent and the unintended elution of other potentially
interfering components.
The solvent elution rate optimum has not been established. However, the general principles of chromatography apply; the solvent should not flow through the column so fast
that it precludes adequate distribution from the solid phase into the mobile phase or flow
so slowly that analysis time is unnecessarily long. Although gravity flow is used here, use
of a vacuum box is recommended, giving greater control over flow rates and permitting
greater ease of handling larger numbers of samples (24,25,47,52).
HPLC was selected for analysis of the triazines. After reviewing the literature on HPLC
of nonvolatile organic compounds, such as the triazines, in environmental samples, it was
decided to use 0.1M ammonium acetate (NH4Ac) as the aqueous portion of the mobile
phase. However, spectroscopic analysis of this solution showed absorbance in the 220- to
240-nm range that interfered with maximum triazine absorbance. A (0.01M) phosphate
buffer (NaH2PO4·H20) that offers no interference with triazine absorption is satisfactorily
substituted in this method. Initially, five wavelengths are monitored from 200 to 260 nm,
but 220 nm consistently gives the best absorbance maximum for all the triazines in this
study. Comparison of the ultraviolet spectra of extracts to standards showed excellent
peak purity. This method has 100% specificity for the four triazines examined individually at the concentrations tested. However, the LC method does not resolve all four compounds simultaneously because cyanazine and simazine have approximately the same
retention times (23). Adjustments in the mobile phase could resolve this problem as would
the use of LC–mass spectrometry or LC–tandem mass spectrometry.
A linear response is observed for daily five-point calibration curves for standards and
MSPD extracts of muscle using mean peak area ratio values of triplicate injections. Correlation coefficients of 0.999 or more were obtained for all calibration curves using standard solutions. Daily standard curves for MSPD-extracted muscle samples have
MSPD for Pesticides in Fish and Foods
11.
12.
13.
14.
293
correlation coefficients ranging from 0.998 to 1.000, with average daily values of 0.999 ±
0.001 for each triazine (23).
This method measured the amount of variability of the test results from the repeated application of the procedure. The intraassay variability or repeatability of the method as
determined by the CV of triplicate injections is below 3% for the triazines at concentrations of 0.35–8 ppm for extracts and all of the standards (23). The interassay variability or
reproducibility of the method varies from approx 5% for metribuzin at concentrations of
0.35 µg/g muscle to 0.39% for muscle containing 2 µg/g using the mean peak area ratio
values for triplicate injections. The overall daily variation for muscle extracts containing
0.35 to 8.0 ppm ranged from 0.89 to 2.43% (23).
Average percentage recoveries range from 75 ± 3% for 0.35-ppm metribuzin to 106 ± 4%
for 0.35-ppm atrazine (N = 9 for extracted pesticides). Data indicate that the MSPD methodology allows successful extraction and determination of all four triazines tested in catfish muscle (23).
This method correctly identifies negative samples because neither method blanks nor
control blanks produces interfering peaks. Therefore, this method has 100% specificity
for the four triazines when examined under the conditions detailed here (23).
The sensitivity of this test is evaluated by its ability to correctly identify the samples
known to be positive for triazines in fortified tissues ranging from 0.35 to 8 ppm. This
method has 100% sensitivity for the four triazines examined individually at the concentrations tested. The levels tested are not meant to reflect the limit of detection of the
method but rather the limit of quantitation as determined from the concentrations examined. This method has a proven limit of quantitation of 350 ppb for each triazine and
represents a starting point in quantitating toxic levels in fish muscle, which are significantly higher (23). Indeed, the sensitivity of the present method could be immediately
enhanced by injection of 50–100 µL of reconstituted extract vs 10 µL as used here.
References
1. Albero, B., Sanchez-Brunete, C., and Tadeo, J.L. (2003) Determination of organophosphorus pesticides in fruit juices by matrix solid-phase dispersion and gas chromatography.
J. Agric. Food Chem. 51, 6915–6921.
2. Giza, I. and Sztwiertnia, U. (2003) Gas chromatographic determination of azoxystrobin
and trifloxystrobin residues in apples. Acta Chromatogr. 13, 226–229.
3. Husain, S. W., Kiarostami, V., Morrovati, M., and Tagebakhsh, M. R. (2003) Multiresidue
determination of diazinon and ethion in pistachio nuts by use of matrix solid phase dispersion with a lanthanum silicate co-column and gas chromatography. Acta Chromatogr. 13,
208–214.
4. Kastelan-Macan, M. and Babic, S. (2003) Pesticides, in Handbook of Thin-Layer Chromatography, 3rd ed. Chromatographic Science Series, Vol. 89, pp. 767–805.
5. Tadeo, J. L. and Sanchez-Brunete, C. (2003) Analysis of pesticide residues in fruit
juices by matrix solid-phase dispersion and gas chromatographic determination.
Chromatographia 57, 793–798.
6. Li, Z.-Y., Zhang, Z.-C,, Zhou, Q.-L., Wang, Q.-M., Gao, R.-Y., and Wang, Q.-S. (2003)
Stereo- and enantioselective determination of pesticides in soil by using achiral and chiral
liquid chromatography in combination with matrix solid-phase dispersion. J. AOAC Int.
86, 521–528.
7. Morzycka, B. (2002) Determination of organophosphorus pesticides in fruits and vegetables by matrix solid-phase dispersion method. J. Plant Protect. Res. 42, 17–22.
294
Barker
8. Fernandez, M., Pico, Y., and Manes, J. (2002) Rapid screening of organophosphorus pesticides in honey and bees by liquid chromatography–mass spectrometry. Chromatographia
56, 577–583.
9. Morzycka, B. (2002) Simple method for the determination of trace levels of pesticides in
honeybees using matrix solid-phase dispersion and gas chromatography. J. Chromatogr.
A 982, 267–273.
10. Michel, M. and Buszewski, B. (2002) HPLC determination of pesticide residue isolated
from food matrices. J. Liq. Chromatogr. Relat. Technol. 25, 2293–2306.
11. Blasco, C., Font, G., and Pico, Y. (2002) Comparison of microextraction procedures to
determine pesticides in oranges by liquid chromatography-mass spectrometry. J.
Chromatogr. A 970, 201–212.
12. Bordajandi, L. R., Merino, R., and Jimenez, B. (2001) Organochlorine exposure in peregrine falcon (Falco peregrinus) eggs and its avian prey (Columbia livia). Organohalogen
Comp. 52 (Dioxin 2001), 139–142.
13. Perret, D., Gentili, A., Marchese, S., Sergi, M., and D’Ascenzo, G. (2002) Validation of a
method for the determination of multiclass pesticide residues in fruit juices by liquid chromatography/tandem mass spectrometry after extraction by matrix solid-phase dispersion.
J. AOAC Int. 85, 724–730.
14. Blasco, C., Pico, Y., and Font, G. (2002) Monitoring of five postharvest fungicides in fruit
and vegetables by matrix solid-phase dispersion and liquid chromatography/mass spectrometry. J. AOAC Int. 85, 704–711.
15. Sanchez-Brunete, C., Albero, B., Miguel, E., and Tadeo, J. L. (2002) Determination of
insecticides in honey by matrix solid-phase dispersion and gas chromatography with nitrogen-phosphorus detection and mass spectrometric confirmation. J. AOAC Int. 85, 128–133.
16. Ahmed, F. E. (2001) Analyses of pesticides and their metabolites in foods and drinks.
Trends Anal. Chem. 20, 649–661.
17. Yague, C., Bayarri, S., Lazaro, R., Conchello, P., Arino, A., and Herrera, A. (2001)
Multiresidue determination of organochlorine pesticides and polychlorinated biphenyls in
milk by gas chromatography with electron-capture detection after extraction by matrix
solid-phase dispersion. J. AOAC Int. 84, 1561–1568.
18. Pous, X., Ruiz, M. J., Pico, Y., and Font, G. (2001) Determination of imidacloprid,
metalaxyl, myclobutanil, propham, and thiabendazole in fruits and vegetables by liquid
chromatography–atmospheric pressure chemical ionization-mass spectrometry. Fresenius
J. Anal. Chem. 371, 182–189.
19. Albero, B., Sanchez-Brunete, C., and Tadeo, J. L. (2001) Multiresidue determination of
pesticides in honey by matrix solid-phase dispersion and gas chromatography with electron-capture detection. J. AOAC Int., 84, 1165–1171.
20. Valenzuela, A. I., Pico, Y., and Font, G. (2001) Determination of five pesticide residues in
oranges by matrix solid-phase dispersion and liquid chromatography to estimate daily intake of consumers. J. AOAC Int. 84, 901–909.
21. Kristenson, E. M., Haverkate, E. G. J., Slooten, C. J., Ramos, L., Vreuls, R. J. J., and
Brinkman, U. A. T. (2001) Miniaturized automated matrix solid-phase dispersion extraction of pesticides in fruit followed by gas chromatographic–mass spectrometric analysis.
J. Chromatogr. A 917, 277–286.
22. Curren, M. S. S. and King, J. W. (2001) Ethanol-modified subcritical water extraction
combined with solid-phase microextraction for determining atrazine in beef kidney. J.
Agric. Food Chem. 49, 2175–2180.
23. Gaunt, P. and Barker, S. A. (2000) Matrix solid phase dispersion extraction of triazines
from catfish tissues; examination of the effects of temperature and dissolved oxygen on
the toxicity of atrazine. Int. J. Environ. Pollut. 13, 284–312.
MSPD for Pesticides in Fish and Foods
295
24. Barker, S. A. (2000) Matrix solid-phase dispersion. J. Chromatogr. A 885, 115–127.
25. Barker, S. A. (2000) Applications of matrix solid-phase dispersion in food analysis. J.
Chromatogr. A 880, 63–68.
26. Valenzuela, A. I., Pico, Y., and Font, G. (2000) Liquid chromatography/atmospheric pressure chemical ionization–mass spectrometric analysis of benzoylurea insecticides in citrus
fruits. Rapid Commun. Mass Spectrom. 14, 572–577.
27. Valenzuela, A. I., Redondo, M. J., Pico, Y., and Font, G. (2000) Determination of
abamectin in citrus fruits by liquid chromatography–electrospray ionization mass spectrometry. J. Chromatogr. A 871, 57–65.
28. Fernandez, M., Pico, Y., and Manes, J. (2000) Determination of carbamate residues in
fruits and vegetables by matrix solid-phase dispersion and liquid chromatography-mass
spectrometry. J. Chromatogr. A 871, 43–56.
29. Valenzuela, A. I., Lorenzini, R., Redondo, M. J., and Font, G. (1999) Matrix solid-phase
dispersion microextraction and determination by high-performance liquid chromatography
with UV detection of pesticide residues in citrus fruit. J. Chromatogr. A 839, 101–107.
30. Dorea, H. S. and Lancas, F. M. (1999) Matrix solid-phase dispersion extraction of organophosphorus and synthetic pyrethroid pesticides in cashew nut and passion fruit. J.
Microcolumn Sep. 11, 367–375.
31. Torres, C. M., Pico, Y., Marin, R., and Manes, J. (1997) Evaluation of organophosphorus
pesticide residues in citrus fruits from the Valencian Community (Spain). J. AOAC Int. 80,
1122–1128.
32. Torres, C. M., Pico, Y., and Manes, J. (1997) Comparison of octadecylsilica and graphitized carbon black as materials for solid-phase extraction of fungicide and insecticide residues from fruit and vegetables. J. Chromatogr. A 778, 127–137.
33. Crouch, M. D. and Barker, S. A. (1997) Analysis of toxic wastes in tissues from aquatic
species. Applications of matrix solid-phase dispersion. J. Chromatogr. A 774, 287–309.
34. Yago, L. S. (1996) Matrix solid-phase dispersion: the next step in solid phase extraction
for food samples? An overview of the technology. Sem. Food Anal. 1, 45–54.
35. Viana, E., Molt, J. C., and Font, G. (1996) Optimization of a matrix solid-phase dispersion
method for the analysis of pesticide residues in vegetables. J. Chromatogr. A 754, 437–444.
36. Tekel, J. and Hatrik, S. (1996) Pesticide residue analyses in plant material by chromatographic methods: clean-up procedures and selective detectors. J. Chromatogr. A 754,
397–410.
37. Obana, H. and Hori, S. (1996) Latest analytical methods for the residual pesticides in
foods. Jpn. J. Toxicol. Environ. Health 42, 1–16.
38. Torres, C. M., Pico, Y., and Manes, J. (1995) Analysis of pesticide residues in fruit and
vegetables by matrix solid-phase dispersion (MSPD) and different gas chromatography
element-selective detectors. Chromatographia 41, 685–692.
39. Torres, C. M., Pico, Y., Redondo, M. J., and Manes, J. (1996) Matrix solid-phase dispersion extraction procedure for multiresidue pesticide analysis in oranges. J. Chromatogr. A
719, 95–103.
40. Schenck, F. J. and Wagner, R. (1995) Screening procedure for organochlorine and organophosphorus pesticide residues in milk using matrix solid phase dispersion (MSPD) extraction and gas chromatographic determination. Food Addit. Contam. 12, 535–541.
41. Ling, Y.-C. and Huang, I.-P. (1995) Multiresidue-matrix solid-phase dispersion method
for determining 16 organochlorine pesticides and polychlorinated biphenyls in fish.
Chromatographia 40, 259–266.
42. Ling Y. C. and Huang, I. P. (1995) Multi-residue matrix solid-phase dispersion method for
the determination of six synthetic pyrethroids in vegetables followed by gas chromatography with electron capture detection. J. Chromatogr. A, 695, 75–82.
296
Barker
43. Pico, Y., Molto, J. C., Manes, J., and Font, G. (1994) Solid phase techniques in the extraction of pesticides and related compounds from foods and soils. J. Microcolumn Sep. 6,
331–359.
44. Lott, H. M. and Barker, S. A. (1993) Comparison of a matrix solid phase dispersion and a
classical extraction method for the determination of chlorinated pesticides in fish muscle.
Environ. Monit. Assess. 28, 109–116.
45. Walker, C. C., Lott, H. M., and Barker, S. A. (1993) Matrix solid-phase dispersion extraction and the analysis of drugs and environmental pollutants in aquatic species. J.
Chromatogr. 642, 225–242.
46. Lott, H. M. and Barker, S. A. (1993) Extraction and gas chromatographic screening of 14
chlorinated pesticides in crayfish (Procambarus clarkii) hepatopancreas. J. AOAC Int. 76,
663–668.
47. Barker, S. A., Long, A. R., and Hines, M. E., II. (1993) Disruption and fractionation of
biological materials by matrix solid-phase dispersion. J. Chromatogr. 629, 23–34.
48. Lott, H. M. and Barker, S. A. (1993) Matrix solid-phase dispersion extraction and gas
chromatographic screening of 14 chlorinated pesticides in oysters (Crassostrea virginica).
J. AOAC Int. 76, 67–72.
49. Stafford, S. C. and Lin, W. (1992) Determination of oxamyl and methomyl by high-performance liquid chromatography using a single-stage postcolumn derivatization reaction
and fluorescence detection. J. Agric. Food Chem. 40, 1026–1029.
50. Long, A. R., Crouch, M. D., and Barker, S. A. (1991) Multiresidue matrix solid-phase
dispersion (MSPD) extraction and gas chromatographic screening of nine chlorinated pesticides in catfish (Ictalurus punctatus) muscle tissue. J. AOAC Chem. 74, 667–670.
51. Long, A. R., Soliman, M. M., and Barker, S. A. (1991) Matrix solid phase dispersion
(MSPD) extraction and gas chromatographic screening of nine chlorinated pesticides in
beef fat. J. AOAC Chem. 74, 493–496.
52. Barker, S. A., Long, A. R., and Short, C. R. (1989) Isolation of drug residues from tissues
by solid phase dispersion. J. Chromatogr. 475, 353–361.
Fungicides by CE–MS
297
23
Analysis of Fungicides in Fruits and Vegetables
by Capillary Electrophoresis–Mass Spectrometry
Yolanda Picó
Summary
A method based on solid-phase extraction (SPE) and capillary electrophoresis–mass
spectrometry (CE–MS) for determining fungicides in fruits and vegetables is described.
The sample, previously chopped and homogenized, is extracted with a methanol–water
mixture by sonication, filtrated, and adjusted to an appropriate volume with water. The
target compounds are isolated by solid-phase extraction (SPE) on C8, eluted with
dichloromethane, evaporated to dryness, and reconstituted in buffer. Fungicide residues
present in the sample are preconcentrated by stacking with buffer removal. Separation is
achieved by capillary zone electrophoresis (CZE) using a buffer of formic acid–ammonium formate at pH 3.5 with 2% methanol and an untreated 150 cm × 75 µm fused-silica
capillary placed in a special external detector adapter (EDA) cartridge. The CE device is
coupled to an electrospray interface by a commercial sheath flow adapter, in which the
CE eluate is mixed with a suitable sheath liquid at the probe tip and then nebulized using
nitrogen gas. The detection of fungicides is carried out on a single quadrupole using
positive ionization and selected ion monitoring modes.
Key Words: Capillary electrophoresis–mass spectrometry; food analysis; fruits; fungicides; solid-phase extraction; vegetables.
1. Introduction
Capillary electrophoresis (CE) is an alternative technique for the rapid and highly
efficient separation of pesticide residues; it resolves the different analytes with an
efficiency similar to gas chromatography (GC) and determines thermally degradable
or nonvolatile molecules like liquid chromatography (LC) (1–6). However, CE suffers
from poor concentration sensitivity because of the small injection volumes (typically
from 1 to 10 nL), which represent <1% capillary length (1,4,5,7,8). This limitation
constitutes a significant obstacle for routine analysis of levels of pesticides below milligrams per kilogram in real samples by this technique (9,10). Alternative detector
formats, such as mass spectrometry (MS), offer greater sensitivity and selectivity than
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
297
298
Picó
ultraviolet absorbance, increasing the applications of this technique to wider types of
analytes and matrices (11–18). Coupling of CE and MS has been described, and the
most common technique for hyphenating capillary separation techniques to the MS
has been electrospray ionization (ESI) (16,19–22).
The routine application of CE–MS still suffers from “electrodrilling” inside the
capillary, large capillary length, and low throughput (15–17). This is reflected by the
fact that almost all CE–MS interfaces described in the literature are custom made (7,8,
12,14,15,18,23). The combination of off-line preconcentration by solid-phase extraction (SPE), which enriches analytes and performs sample cleanup prior to analysis,
and on-line preconcentration or “stacking” represents an effective and versatile way to
enhance concentration sensitivity in CE (4,5,7,8,23). The determination of two fungicides, thiabendazole and procymidone, in fruits and vegetables illustrates how these
approaches are combined to detect their residues at the levels below parts per million,
levels at which they are usually present in real samples.
2. Materials
1. P/ACE MDQ CE system (e.g., Beckman, Fullerton, CA) with an external detector adapter
(EDA; e.g., Beckman).
2. CE–MS/ESI (e.g., Agilent Sprayer Kit, G1607A, Waldbronn, Germany).
3. Mass spectrometer with atmospheric pressure ionization (API)/electrospray source (e.g.,
Hewlett-Packard HP1100, Palo Alto, CA).
4. Pump to add the sheath liquid (e.g. Hewlett-Packard HP1100 series).
5. Procymidone and thiabendazole standards, 99.99% pure.
6. Gradient-grade methanol for LC.
7. Dichloromethane for organic trace analysis.
8. Deionized water.
9. Ammonium formate.
10. Formic acid.
11. Octylsilica sorbent (particle diameter in the range 45–55 µm).
12. 100 mm × 9 mm id glass column fitted with a coarse frit (no. 3) with a standardized
hollow key (14/23) and standard ground cone (29/32) that can be combined with several
laboratory glassware items, such as funnels, Kitasato flasks, vacuum adapters, and the
like. Prepare the glass column by transferring 1 g C8 into it and covering with a plug of
silanized glass wool.
13. An untreated 150 cm × 75 µm id fused-silica capillary.
14. For stock standard solution of procymidone, add 50 mg thiabendazole to 50-mL volumetric flask. Dissolve and bring to volume with methanol. Store in stained glass bottles.
Stable at 4°C for up to 1 mo.
15. For standard mixtures of fungicides, add appropriate volumes of the standard solutions of
procymidone in methanol to 5 mL volumetric flask. Bring to volume with sample buffer.
Make fresh mixtures as required.
16. Capillary conditioning solution 1: 100 mM NaOH.
17. Capillary conditioning solution 2: deionized water.
18. Separation buffer: 12 mM ammonium formate, 20 mM formic acid, pH 3.5, 2% methanol.
19. Sheath liquid: 12 mM ammonium formate, 20 mM formic acid, pH 3.5, 2% methanol.
20. Sample buffer for stacking of 1.5 mM ammonium formate, 2.5 mM formic acid, at pH 3.5
can be prepared by diluting the separation buffer eight times.
Fungicides by CE–MS
299
21. Fruit and vegetable samples are taken at various places distributed throughout the lot;
they should weigh at least 1 kg and consist of at least 10 individual pieces. The sample is
collected on a net bag and transported to the laboratory within 24 h of pickup. Samples
are stored at 4°C until the analysis.
22. Filter standard solutions, samples, and buffers through a 0.22-µm membrane filter.
3. Methods
The methods detailed below summarize (1) the extraction of fungicides from fruits
using an isolation-and-preconcentration method based on SPE, (2) the coupling of CE
to MS, (3) the capillary electrophoretic separation of both fungicides using a simple
stacking procedure, and (4) their identification and quantification by MS.
3.1. Sample Extraction
Frequently, the fungicides of interest are present at levels too low for detection.
Sample preparation can concentrate the components to adequate amounts for measurement (see Note 1). The extraction, isolation, and concentration of thiabendazole
and procymidone from fruits and vegetables are explained in Subheadings 3.1.1.–
3.1.4. This involves (1) the description of sample pretreatment, (2) the extraction of
fungicides from the solid matrix, (3) the isolation of fungicides using SPE, and (4)
their elution and concentration.
3.1.1. Sample Pretreatment
1. Samples are to be analyzed within 3 d of sample receipt or within 4 d of sample pickup.
Samples are kept at 4°C prior to analysis to prevent disappearance or degradation of
fungicide residues.
2. Analyze the samples unwashed, with the peel intact and, if applicable, stoned.
3. Chop the samples into small pieces using a conventional kitchen knife.
4. Homogenize a representative portion of the sample (200 g whole fruit or vegetable) in a
food chopper (see Note 2).
3.1.2. Pesticide Extraction From the Solid Matrix
1. Weigh a 5-g portion of fruit or vegetable sample and place it into an Erlenmeyer flask.
Add process control or spiking solutions at this step and let the samples stand at room
temperature for 3 h to achieve the solvent evaporation and the fungicide distribution in
the fruit or vegetable.
2. Add 5 mL methanol and 5 mL water and homogenize by sonication for 15 min.
3. Filter the resulting suspension through a Whatman 40-µm filter and wash the filter cake
twice with 5 mL deionized water.
4. Adjust the filtrate to a volume of 100 mL with deionized water.
3.1.3. Solid-Phase Extraction
The SPE is carried out using conventional C8-bonded silica and a glass column produced according to the design specification described in the Subheading 2. (see Note 3).
1. Connect the glass column containing the solid phase to a Kitasato flask.
2. Condition or activate the solid phase using 10 mL methanol and 10 mL water to solvate
the bonded phase. Do not allow the solid phase to dry out to prevent reversion to its
original state.
300
Picó
3. Attach the conditioned glass column to a 200-mL glass funnel.
4. Pump samples through the conditioned solid phase with the aid of vacuum at a flow rate
between 10 and 25 mL/min.
5. Dry the solid phase with air to avoid the coelution of the remaining water with the elution
solvent.
3.1.4. Elution and Concentration
1. Elute fungicides by gravity into a 15-mL conical glass tube with 10 mL of dichloromethane.
2. Apply vacuum to ensure that all dichloromethane is removed from the solid phase.
3. Evaporate the eluate to dryness using a gentle stream of nitrogen at 40°C.
4. Reconstitute the dry residue in 500 µL of 4 mM sample stacking buffer, thoroughly mixing in an ultrasonic bath for 5 min.
5. Transfer to polymerase chain reaction vial for the EC–MS analysis. These vials allow
small sample volumes to be handled. Conventional vials for electrophoresis require at
least 2 mL of sample.
This extraction procedure yields a mean recovery of 65% for thiabendazole and
75% for procymidone. In addition, it provides at least a 10-fold concentration factor,
and the extracts obtained are quite clean, suitable for further determination without
any additional cleanup.
3.2. Coupling CE to the Mass Spectrometer
The connection of a P/ACE System MDQ to a mass selective detector (MSD) is
carried out using a liquid sheath electrospray (ESI) source (see Note 4 and Fig. 1), as
described in Subheadings 3.2.1.–3.2.4. This includes (1) the connection of the system
to deliver the sheath liquid, (2) the preparation of the capillary, (3) the capillary electrophoretic system, and (4) the mass spectrometer. The combination of both instruments requires careful optimization to prevent some coupling problems encountered
in practice (see Note 5). Most frequent difficulties are siphoning, longer migration
times, and lower peak resolution. To avoid siphoning the CE system, put the inlet vial at
the same height as the sprayer tip of MSD (see Note 6). To minimize the second effect,
place both instruments close to each other to allow a short capillary length (see Note 7).
3.2.1. Preparing the System to Deliver the Sheath Liquid
A syringe pump, which can deliver a precise flow rate of 1–25 µL/min, or a conventional LC pump with a flow splitter are the alternatives to deliver the sheath liquid
into the ESI source. In this case, the sheath flow splitter (Fig. 1) (included in the
Agilent CE–MS sprayer kit) has been connected to the pump outlet.
1. Connect the tubing labeled “Pump” to the pump outlet. The recycle or waste tubing may
be drawn back into the sheath liquid bottle to reuse the solvent.
2. Leave the tubing labeled “Out” disconnected from the sprayer but place its end in a beaker. It will be connected later.
3. Fill the sheath liquid in solvent the bottle A of the 1100 pumping system. Open the purge
valve and flush the pump at 2 mL/min (100% A) for 5 min. Reduce the flow rate to 1.3 mL/
min and close the purge valve. The splitter splits the sheath liquid in the ratio 1:100, so the
sheath liquid flow rate will be 13 µL/min. The backpressure at 13 mL/min is approx 130 bar.
Fungicides by CE–MS
301
Fig. 1. Scheme of the instrumental setup of CE coupled to the MS system: (A) capillary
electrophoresis; (B) CE–MS/ESI sprayer; (C) sheath flow splitter; and (D) mass spectrometer.
4. The sheath liquid must be degassed prior to use, which can be done by sonication or by a
vacuum degasser. The vacuum degasser can be directly connected to the pump; in this
case, the flush time should be longer.
3.2.2. Preparing the P/ACE MDQ System
The P/ACE MDQ system works with the EDA, which is designed for connection to
external detectors such as mass spectrometers. The EDA consists of instrument modifications, software changes, and hardware to carry the capillary outside the MDQ.
This modification is not user installable.
The instrument is used with a special EDA cartridge, in which the capillary exits
the instrument and an external ground electrode completes the high-voltage circuits
(Fig. 2). Basic difference with a conventional cartridge is that the inlet side of the
cartridge is blocked (only maintains the cooling liquid circuit). Using an EDA cartridge, the MDQ detector is not available, and the length of capillary from the point
sample injection to the outside of the MDQ is substantially reduced.
The experiments are carried out in the anionic mode (cathode at the inlet and anode
at the outlet) of the MDQ system. When the EDA is installed, the function of the
polarity indicator lights on the front of the MDQ is reversed (the reverse indicator
light will light in normal polarity and vice versa).
302
Picó
Fig. 2. EDA-only vs conventional cartridge.
1. Insert the capillary through the outlet side of the cartridge. Push the capillary through the
cartridge and the outlet side coolant tube until it emerges from the capillary adapter body.
2. Trim the capillary to length using the MDQ trimming template before installing it in the
instrument.
3. Insert the capillary adapter body into the slot in the right side of the MDQ instrument.
Secure it with the locking ring.
3.2.3. Inserting and Adjusting the CE Capillary in the CE–MS/ESI Sprayer
1. Cut the outlet end of the capillary. Make sure that the cut is flat and the capillary is not
shattered at the end because the quality of the cut determines the precision of the spray
and avoids the presence of adsorptive sites for analytes.
2. Remove 2 to 3 mm of the polyamide coating at the tip of the CE capillary by burning it off
and cutting the capillary to make the MS signal more stable.
3. Turn the adjustment screw counterclockwise (+ direction) until its mechanical stop. Then,
turn two complete turns clockwise (− direction).
4. Fix the capillary so that it still can be moved up or down. The capillary should be aligned
flat with the sprayer tip.
5. Tighten the fitting screw tight enough to keep the capillary in place.
6. Turn the adjustment screw a quarter turn counterclockwise (2 mark in + direction).
Finally, the capillary should protrude approx 0.1 mm out of the sprayer tip to obtain a
stable MS signal.
Fungicides by CE–MS
303
3.2.4. Preparing the MSD
1. Connect the nebulizing gas and the sheath liquid to the CE sprayer.
2. Carefully insert the CE sprayer into the electrospray chamber of the MSD. Do not touch
the electrospray chamber with the sprayer tip because it can easily damage the sprayer
tip. Do not hold the sprayer at the adjustment screw while inserting it into the ion source.
This can misalign the sprayer.
3.3. CE Separation
The next step is the separation of the thiabendazole and procymidone using a simple
stacking procedure to enhance sensitivity (see Note 8). CE instrumentation is controlled from a different computer with a System Gold software selecting the EDA
mode so that the adapter functions correctly. It is important to remember that, in the
EDA configuration, the capillary inlet is in the outlet side of the instrument. This
affects programming for both voltage and pressure. The parameters giving in Subheadings 3.3.1. and 3.3.2. are typical for determining the selected analytes in fruit and
vegetable samples. However, they might have to be adapted when other analytes or
other samples are analyzed.
3.3.1. Capillary Equilibration
Prior to first use, a new capillary should be properly conditioned. The CE capillary
should also be reconditioned daily prior to experimental use to obtain a stable baseline
in the detection system.
Equilibrate the capillary, executing in order the following high-pressure (20-psi)
forward rinse steps:
0.1M sodium hydroxide for 20 min
Deionized water for 10 min
Separation buffer for 80 min
When the sheath liquid is running, there is no need to remove the capillary from the
system.
3.3.2. Stacking and Separation of the Compounds
1. Perform a rinse flushing the capillary with the running buffer, 2 min at 20 psi, from a vial
that contains separation buffer at a temperature of 16°C because application of the lowest
thermostated temperature improves the resolution of the compounds.
2. Inject the sample hydrodynamically by pressure (0.5 psi) for 15 s.
3. Apply a negative voltage of −30 kV to the inlet end of the capillary.
4. When the current is 95% of the original running buffer, turn off the electrodes (see Note 8).
5. Carry out the separation with a positive power supply of 30 kV (average current 5.5 µA)
at a temperature of 16°C.
Using the “stacking” technique, the analytes are concentrated fivefold compared
with the standard injection (hydrodynamic injection, 0.5 s, 0.5 psi) (see Fig. 3). The
sensitivity is not dramatically improved by the stacking, but the detection limits are
better, and the peak shape is maintained.
The separation technique provides peak efficiencies higher than 4,520,000 (plates
number) and resolution factor (R’s) between both compounds up to 0.6.
304
Picó
Fig. 3. CE–MS/ESI electropherograms in the selected ion monitoring mode of thiabendazole and procymidone standards (0.1 and 1 µg/mL) obtained by (A) standard injection and (B)
stacking with matrix removal.
3.4. MS Identification and Quantification
Described below are the steps that can be utilized in the determination of thiabendazole and procymidone by MS. The MSD, data acquisition, and handling are controlling by an independent computer by the LC ChemStation software (Agilent).
1. Set the spray chamber and mass spectrometer parameter (see Table 1 and Note 9).
2. Analysis start/stop signals are provided by relay contacts on the CE instruments that are
closed only during separation.
The peaks corresponding to thiabendazole and procymidone can be seen in the chromatograms at the retention times of 7.8 and 8.5 min, respectively (see Fig. 4). The
detection limits obtained are 0.03 and 0.003 µg/mL for procymidone and thiabenda-
Fungicides by CE–MS
305
Table 1
Parameters of the Spray Chamber and Mass Spectrometer
Parameter
General information
Use MSD
Ionization mode
Polarity
Stop time
SIM parameters
Ions selected
Gain
Dwell time (ms)
Spray chamber parameters
Drying gas flow
Drying gas temperature
Nebulizing gas pressure
Voltage of the capillary
Fragmentor voltage
Value
Enable
API/ES
Positive
12 min
m/z 202 for thiabendazole
m/z 284 for procymidone
3
349
11 L/min
150°C
40 psi
4000 V
100 V
zole, respectively (see Fig. 4A). The electropherograms displayed after extraction of
fruit or vegetables samples that did not contain the studied fungicides show a stable
baseline without interfering peaks caused by endogenous compounds (see Fig. 4B).
The analysis of spiked sample extract shows no matrix interferences. The method provides quantification limits of 0.05 mg/kg for procymidone and 0.005 mg/kg for thiabendazole, making the determination reliable in real matrices (see Fig. 4C).
4. Notes
1. Multiple methods can be utilized to extract, isolate, and concentrate the fungicides present
in fruit and vegetables. Methods such as solid–liquid extraction with organic solvents
followed by liquid–liquid partitioning or solid-phase cleanup have been widely reported
in the literature, and all can be combined with CE to analyze fungicides (1–3,6,23). However, the detection limits obtained should meet the criterion of being lower (at least twice)
than the maximum residue limits established by the European Union (EU). Because of this,
it is interesting that the selected method achieves a concentration factor of at least fivefold.
The SPE procedure proposed easily provides concentration factors of 10-fold or more.
2. Good sample preparation is essential for accurate results with only a few sample measurements. Sample homogenization is the most neglected step in the analysis of fungicides in fruit and vegetables. If too large samples are taken, the time required for the
homogenization is much too long, and the matrix is not homogeneous enough. On the
contrary, small sample sizes can be little representative of the entire sample.
3. The SPE system reported here has been utilized very effectively to analyze different pesticides from water and aqueous extracts of fruit and vegetables (10,24–26). Other SPE
systems have also proven to be very effective in isolating and concentrating pesticides
prior to CE. Some of these include different formats (cartridges, syringes, and disks) and
306
Picó
Fig 4. CE–MS/ESI electropherograms in the selected ion monitoring mode of (A) thiabendazole and procymidone standards (0.1 and 1 µg/mL), (B) untreated control orange sample, and
(C) control orange sample spiked at 0.01 and 0.1 mg/kg, respectively. Reprinted from ref. 25
with permission from Elsevier Science.
Fungicides by CE–MS
4.
5.
6.
7.
8.
307
several sorbents [in addition to the traditional bonded silicas, C18 especially designed for
polar compounds, several styrene–divinylbenzene copolymers, graphitized carbon blacks,
and poly(divinylbenzene-co-N-vinylpyrrolidone) copolymers) (4–6,23).
CE is most often interfaced to MS with the aid of an ESI source. The liquid sheath ESI
source, first introduced by Smith et al. (27), has become the most popular choice because
it can most easily accommodate the high-concentration buffer systems typically used as
eluents in CE and can tolerate both high and low electrosmotic flow rates as well. In a
typical liquid sheath ESI configuration, the CE capillary is inserted in a stainless steel
needle with an inner diameter that closely matches the outer diameter of the fused-silica
capillary. The ESI voltage is applied to this metal needle. A liquid sheath, usually a mixture of CH3OH/H2O/CH3COOH, is supplied through the needle around the last section of
the CE capillary. The liquid sheath serves two main purposes: (1) it provides electrical
contact at the CE capillary terminus, and (2) it dilutes the CE background electrolyte,
making it electrosprayable. The composition of sheath liquid affects ESI sensitivity and
CE resolution. The best results are mostly obtained when the composition of sheath liquid
is similar to the running buffer.
When a liquid sheath ESI source is used to couple CE to MS, variations in migration time
and loss of separation efficiency are sometimes experienced. Increased migration times
(compared to ultraviolet detection) can simply be a result of the extra column length
necessary to allow interfacing of the two techniques. However, there are several other
factors that may interfere with and alter the separation efficiency and migration times,
such as moving ionic boundaries; buffer depletion (toward the end of the CE capillary in
a hot ESI source); penetration of the liquid sheath by diffusion into the CE capillary;
electrode reaction at the ESI needle, which may result in pH modification; suction effect
induced by the sheath gas flow used in addition to the liquid sheath flow; and alteration of
electrosmotic flow by the radial electric field that penetrates across the fused silica capillary wall. In addition, the separation efficiency may also be compromised by the data
acquisition speed, the response time of the mass spectrometer, the liquid sheath flow rate,
and the relative positioning of the CE capillary and the ESI needle.
Siphoning of the sample is caused by a pressure difference between the inlet and the
outlet. The solution is to keep both capillary ends at approximately the same height, which
is ± 0.5 cm around the sprayer’s levels, using a height-adjustable table placed under the
CE instrument. However, typically this position is reached by placing both instruments in
the same bench without more adjustment.
A standalone CE system maintains the capillary thermostated at a fixed temperature and
handles separation capillary length from 20 to 50 cm because the detector is internal and
close to the capillary. The coupling to an external mass spectrometer requires considerably extended capillaries with an overall length of 60 cm or more. As the mobility of an
ion is proportional to the applied field strength, the latter is inversely proportional to the
capillary length, which means that migration time is increased. In addition, only a small
portion of the capillary is thermostated, and a large part of it (that between the CE outlet
and the MS/ESI) is at room temperature. As the resolution between analytes is inversely
proportional to the Joule effect, the peak resolution diminishes.
The term stacking was coined to describe any on-capillary mode of concentrating analytes
based on changes of electrophoretic mobility because of the electric field across the concentration boundaries. The injected samples are prepared in a lower ionic strength buffer
than the separation one. When the separation voltage is applied across the capillary, the
analytes move quickly through the sample until they reach the buffer zone, where they
slow because the high ionic strength of the separation buffer achieving analytes’ concen-
308
Picó
tration. The optimum sample plug length that can be injected into the capillary without
loss of separation efficiency is the limitation of the stacking. The sample volume injected
can be increased if the sample buffer is removed after stacking by reversing the polarity.
The stacking efficiency depends on the injection time, injection plug length, and ratio of
conductivity between the separation sample and buffers.
9. The parameters of the mass spectrometer should be checked and optimized in full-scan
mode prior to setting the instrument in selected ion monitoring mode because some variations and particular characteristics can be observed depending on the type and model of
mass spectrometer, the individual tuning of the instrument, or the trademark of the
reactives used as buffer or sheath liquid. For example, procymidone tends to form cluster
ions with NH4+ that can be the observed ion instead of the protonated molecule.
Acknowledgments
This research was supported by the Ministry of Science and Technology, Spain
together with the European Regional Developments Funds (ERDF) (project AGL200301407).
References
1. Picó, Y., Rodríguez, R., and Mañes, J. (2003) Capillary electrophoresis for the determination of pesticide residues. Trends Anal. Chem. 22, 133–151.
2. Karcher, A. and El Rassi, Z. (1999) Capillary electrophoresis and electrochromatography
of pesticides and metabolites. Electrophoresis 20, 3280–3296.
3. Malik, A. K. and Faubel, W. (2001) A review of analysis of pesticides using capillary
electrophoresis. Crit. Rev. Anal. Chem. 31, 223–279.
4. Martínez, D., Borrull, F., and Calull, M. (1999) Strategies for determining environmental
pollutants at trace levels in aqueous samples by capillary electrophoresis. Trends Anal.
Chem. 18, 282–291.
5. Martínez, D., Cugat, M. J., Borrull, F., and Calull, M. (2004) Solid-phase extraction coupling to capillary electrophoresis with emphasis on environmental analysis. J. Chromatogr.
A 902, 65–89.
6. Menzinger, F., Schmitt-Kopplin, P., Freitag, D., and Kettrup, A. (2000) Analysis of agrochemicals by capillary electrophoresis. J. Chromatogr. A 891, 45–67.
7. Shihabi, Z. K. (2000) Stacking in capillary zone electrophoresis. J. Chromatogr. A 902,
107–117.
8. Osbourn, D. M., Weiss, D. J., and Lunte, C. E. (2000) On-line preconcentration methods
for capillary electrophoresis. Electrophoresis 21, 2768–2779.
9. Rodríguez, R., Picó, Y., Font, G., and Mañes, J. (2001) Determination of urea-derived
pesticides in fruit and vegetables by solid-phase preconcentration and capillary electrophoresis. Electrophoresis 22, 2010–2016.
10. Rodríguez, R., Boyer, I., Font, G., and Picó, Y. (2001) Capillary electrophoresis for the
determination of thiabendazole, prochloraz and procymidone in grapes. Analyst 126, 2138.
11. Song, X. and Budde, W. L. (1998) Determination of chlorinated acid herbicides and related compounds in water by capillary electrophoresis-electrospray negative ion mass
spectrometry. J. Chromatogr. A 829, 327–340.
12. Otsuka, K., Smith, C. J., Grainger, J., et al. (1998) Stereoselective separation and detection of phenoxy acid herbicide enantiomers by cyclodextrin-modified capillary zone electrophoresis–electrospray ionization mass spectrometry. J. Chromatogr. A 817, 75–81.
Fungicides by CE–MS
309
13. Tsai, C. Y., Chen, Y. R., and Her, G. R. (1998) Analysis of triazines by reversed electroosmotic flow capillary electrophoresis–electrospray mass spectrometry. J. Chromatogr. A
813, 379–386.
14. Lazar, I. M. and Lee, M. L. (1999) Capillary electrophoresis time-of-flight mass spectrometry of paraquat and diquat herbicides. J. Microcolumn Sep. 11, 117–123.
15. Menzinger, F., Schmitt-Kopplin, P., Frommberger, M., Freigtag, D., and Kettrup, A.
(2001) Partial-filling micellar electrokinetic chromatography and non-aqueous capillary
electrophores for the analysis of selected agochemicals. J. Chromatogr. A 371, 25–34.
16. Hau, J. and Roberts, M. (1999) Advantages of pressurization in capillary electrophoresis/
electrospray ionization mass spectrometry. Anal. Chem. 71, 3977–3984.
17. Goodwin, L., Startin, J. R., Keely, B. J., and Goodall, D. M. (2003) Analysis of glyphosate
and glufosinate by capillary electrophoresis–mass spectrometry utilising a sheetless
microelectrospray interface. J. Chromatogr. A 1004, 107–119.
18. Núñez, O., Moyano, E., and Galceran, M. T. (2002) Capillary electrophoresis–mass
spectrometry for the analysis of quaternary ammonium herbicides. J. Chromatogr. A
974, 243–255.
19. Niessen, W. M. A., Tjaden, U. R., and van der Greef, J. (1993) Capillary electrophoresismass spectrometry. J. Chromatogr. A 636, 3–19.
20. Nielen, M. W. F. (1995) Industrial applications of capillary zone electrophoresis-mass
spectrometry. J. Chromatogr. A 712, 269–284.
21. Tanaka, Y., Otsuka, K., and Terabe, S. (2003) Evaluation of an atmospheric pressure
chemical ionization interface for capillary electrophoresis–mass spectrometry. J. Pharm.
Biomed. Anal. 30, 1889–1895.
22. Schmitt-Kopplin, P. and Frommberger, M. (2003) Capillary electrophoresis–mass spectrometry. Fifteen years of developments and applications. Electrophoresis 24, 3837–3867.
23. Da Silva, C. L., de Lima, E. C., and Tavares, M. F. M. (2003) Investigation of
preconcentration strategies for the trace analysis of multi-residue pesticides in real samples
by capillary electrophoresis. J. Chromatogr. A 1014, 109–116.
24. Rodríguez, R., Mañes, J., and Picó, Y. (2003) Off-line solid-phase microextraction and
capillary mass spectrometry to determine acidic pesticides in fruits. Anal. Chem. 75,
452–459.
25. Rodríguez, R., Picó, Y., Font, G., and Mañes, J. (2002) Analysis of thiabendazole and
procymidone in fruits and vegetables by capillary-electrophoresis-electrospray mass spectrometry. J. Chromatogr. A 949, 359–366.
26. Rodríguez, R., Picó, Y., Font, G., and Mañes, J. (2001) Analysis of post-harvest fungicides by micellar electrokinetic chromatography. J. Chromatogr. A 924, 387–396.
27. Smith, R. D., Barinaga, C. J., and Udseth, H. R. (1998) Improved electrospray ionization
for capillary zone electrophoresis–mass spectrometry. Anal. Chem. 60, 1948–1952.
Residues in Grain and Dried Foodstuffs
311
24
Application of Supercritical Fluid Extraction
for the Analysis of Organophosphorus Pesticide Residues
in Grain and Dried Foodstuffs
Kevin N. T. Norman and Sean H. W. Panton
Summary
A supercritical fluid extraction (SFE) method using carbon dioxide (CO2) and cleanup
by solid-phase extraction (SPE) with graphitized carbon black is presented. Gas chromatography using flame photometric detection (GC/FPD) and gas chromatography–mass
spectrometric detection (GC–MSD) allow the quantitative determination of organophosphorus (OP) pesticide residues in grains such as wheat, maize, and rice as well as other
dried foodstuffs such as cornflakes and kidney beans. The method is robust and sensitive, allowing residues to be determined down to 0.05 mg/kg or lower using GC–MSD.
Extraction, cleanup, and determination are automated, allowing higher sample throughput compared to methods using solvent extraction and gel permeation chromatography.
Solvent consumption is minimal using the SFE method, and hazardous waste is reduced.
The SFE and cleanup methods used are likely to be suitable for the determination of OP
pesticide residues in other dried foodstuffs without the need to alter the SFE or SPE
conditions.
Key Words: Cereals; dried foods; flame photometric detection; gas chromatography; grains; mass spectrometric detection; organophosphorus pesticides; supercritical
fluid extraction.
1. Introduction
Current methodologies to determine pesticide residues usually use liquid extraction (1,2), often incorporating a partitioning stage, concentration of extract, as well as
a cleanup stage prior to determination using chromatography. Such manual methods
are labor intensive, need many hours of analyst time, and use large volumes of solvent
that require disposal. An attractive alternative is to use supercritical fluids, which are
substances above their critical temperature and pressure. Supercritical fluids have densities similar to liquids, but lower viscosities and higher diffusion coefficients. This
combination of properties results in a fluid that is more penetrative, has a higher solvating power, and will extract solutes faster than liquids.
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
311
312
Norman and Panton
A number of supercritical fluid extraction (SFE) studies suggested recoveries of
pesticides are higher using SFE than those obtained using liquid extraction (3–6), and
extracts are potentially cleaner (7,8). Supercritical carbon dioxide (CO2) is a suitable
fluid for the extraction of pesticide residues and has the additional advantages of a low
critical point (31.05°C, 74.8 bar) (9), ready availability, and relatively low toxicity.
Commercial SFE instruments control supercritical conditions and automatically extract samples and collect analytes on sorbent traps, cryogenic traps, or in solvent. Extracts may then be analyzed directly, concentrated, or cleaned up prior to determination
by chromatography using an appropriate detector. Once conditions are established,
routine extractions are straightforward, and labor costs are reduced compared to conventional liquid extraction.
In this chapter, an automated method is described for the SFE of organophosphorus
(OP) pesticides from grains and dried foodstuffs. Pesticides are collected on an
octadecylsilane (ODS) sorbent trap and desorbed by acetone prior to clean up using
automated solid-phase extraction (SPE) with ENVI-Carb cartridges (e.g., Supelco,
Poole, UK) (10). This method allows the analyst to prepare eight extracts in 2.5 h
compared to 9 h using conventional liquid extraction and gel permeation chromatography (11). The approach is robust, avoids the need for cleanup using gel permeation
chromatography, and is suitable for many low-moisture food commodities, including
cereals such as wheat, maize, white rice, and brown rice, as well as other dried foodstuffs, such as kidney beans and cornflakes. Conditions for determination using gas
chromatography with flame photometric detection (GC/FPD) and mass spectrometric
(MS) detection are also provided.
2. Materials
1. Supercritical fluid extractor (e.g., Agilent 7680T, Palo Alto, CA,); 7-mL extraction
thimbles; end caps (e.g., Crawford Scientific, Strathaven, UK).
2. Glen Creston (Stanmore, UK) Retsch sample divider.
3. Glen Creston type 11-500 Laboratory Disc Mill (see Note 1) using a setting of 10.
4. Screen that allows 1 mm or smaller particles to pass through when sieving (e.g., Endecotts
Ltd., London, UK).
5. Organic solvents (acetone, acetonitrile, toluene) suitable for pesticide residue analysis.
6. Pesticide standards as required.
7. 50- to 100-mesh acid washed sand, general purpose reagent (GPR; see Note 2).
8. Whatman GF/F 15-mm diameter glass microfiber filter disk.
9. ODS 50-µm particles (IST, Hengoed, UK; see Note 3) for use in the SFE sorbent trap.
10. SFE-grade CO2 (99.995% pure), industrial Grade cryogenic CO2 with dip tube (99.95%
pure; see Note 4).
11. 2-mL Autosampler vials sealed with a polytetrafluoroethylene-faced septum for collecting SFE extracts and GC autosampler vials.
12. Acetonitrile:toluene (3:1 v/v) SPE elution solvent.
13. Automated Gilson ASPEC XL (e.g., Villiers-Le-Bel, France) with 6-mL cartridges containing ENVI-Carb (500 mg).
14. Techne DB 3-A, Dri-block, and Techne sample concentrator for blowing down of extracts (Techne, Princeton, NJ).
15. Corning Pyrex disposable borosilicate culture tube, 85 mm × 15 mm (New York, NY).
Residues in Grain and Dried Foodstuffs
313
16. Gas chromatograph (e.g., Agilent model 5890 Series II, Waldborn, Germany) fitted with
an FPD; 30 m × 0.25 mm DB-5, with a film thickness of 0.25 µm (e.g., J&W Scientific,
Folsom, CA); model 7673 autosampler; computer data acquisition system using
ChemStation software, version A 08.03 (Agilent).
17. Gas chromatograph (e.g., Agilent model 5890 Series II, Waldborn, Germany) fitted with
an electron impact ionization (70-eV) mass spectrometric detector (e.g., Agilent model
5971, Palo Alto, CA); 30 m × 0.25 mm DB-5 MS, with a film thickness of 0.25 µm (e.g.,
J&W Scientific); computer data acquisition system using ChemStation software,
G1034.C, version C 03.00.
3. Methods
3.1. Preparation of Solutions for Calibration
1. Prepare individual pesticide standard stock solutions of 1000 µg/mL in acetone and a
standard mix containing 40 µg/mL of each of the pesticides in acetone from the individual standard stocks.
2. Use the standard mix to prepare solutions for spiking samples and matrix-matched standards appropriately diluted (see Notes 5 and 6).
3.2. Sample Storage and Homogenization
1. Store samples in a freezer (–18°C or lower).
2. Homogenize laboratory samples (2 kg) using the sample divider and recombining fractions from the sample divider.
3. Take a portion of the recombined fractions (500 g) and mill to a coarse powder/particles
(see Note 7).
4. Store milled samples at –18°C or lower.
3.3. SFE Unit Preparations
1. Prepare the SFE trap by removing the old packing material and frit, taking care not to
damage the screw thread of the trap.
2. Insert new frit and add fresh ODS using the supplied Agilent funnel.
3. Pack down using gentle tapping on the bench; do not pack down using glass rod or similar
(see Note 8).
4. Install the SFE trap in the SFE unit and perform a system check using an empty extraction
thimble and end caps prior to an extraction sequence (see Note 9). When the system
check is successful, prepare samples for SFE sequence.
3.4. Preparation of Samples and Spiked Samples for SFE Sequence (see Fig. 1)
1. Place a glass microfiber filter disk in the bottom of an SFE extraction thimble and pack
with milled sample (3.1–3.8 g) using a funnel (see Note 10).
2. Fill any dead volume with sand, tap down (adding more sand if required), and top with a
glass microfiber filter disk before sealing with an SFE thimble end cap. A typical extraction sequence may contain eight samples or fewer if quality control samples are required.
3. Prepare spiked samples by adding 90 µL of acetone containing OP pesticides (2 or 20 µg/
mL) using a microliter syringe to milled sample (3.1–3.8 g) known not to contain pesticide residues (see Note 6). This corresponds to a residue of approx 0.05 or 0.5 µg/g.
4. Allow the solvent to evaporate for 10 min (see Note 11).
314
Norman and Panton
Fig. 1. Packing of the SFE extraction thimble.
3.5. Sample Extraction
1. Load extraction thimbles into SFE unit and insert appropriate number of capped
autosampler vials in the SFE collection carousel.
2. Enter the SFE parameters into the SFE unit. Suggested extraction conditions are 5 min
static extraction period at 245 bar and 70°C (0.73 g/mL density), followed by a 35-min
dynamic extraction period at a flow rate of 1.0 mL/min.
3. Collect analytes following decompression of CO2 on an ODS trap at 10°C with a nozzle
temperature of 50°C.
4. Use acetone (1.5 mL) to desorb the ODS trap at 30°C with a flow rate of 2 mL/min into a
2-mL vial sealed with a polytetrafluoroethylene-faced septa.
5. Rinse the trap with 5 mL acetone at 30°C to waste to reduce the possibility of analyte
carryover.
6. Remove SFE extracts from SFE unit, quantitatively transfer extracts to 2-mL volumetric
flasks, and bring to volume with acetone (see Note 12).
3.6. SPE Cleanup of SFE Extract for GC Analysis
1. Transfer contents of 2-mL volumetric flask to an 85 × 15 mm borosilicate culture tube
and seal with parafilm (see Note 13).
2. Enter the SPE parameters into the SPE unit.
3. Condition the cartridges with 5 mL SPE elution solvent at a flow rate of 5 mL/min.
4. Load 1 mL SFE extract onto the cartridge (5 mL/min) and elute with 5 mL elution solvent
(1 mL/min).
5. Collect in a Corning Pyrex disposable borosilicate culture tube.
6. Reduce the extract to near dryness (0.2 mL) under nitrogen using a Techne dry block
(45°C; see Note 14), and transfer the residuum to a 2-mL volumetric flask using three
0.5-mL aliquots of acetone, and bring to volume.
7. Transfer aliquots to GC autosampler vial ready for analysis.
Residues in Grain and Dried Foodstuffs
315
3.7. Analysis of Extracts Using GC/FPD
1. Inject 1 µL of cleaned SFE extract into a split/splitless injector containing a 4-mm id
deactivated single-taper liner at 250°C with the split vent opening after 0.75 min (see
Note 15).
2. Use helium as carrier gas with electronic pressure control to maintain a linear velocity of
about 30 cm/s.
3. Hold the column temperature at 100°C for 1 min, program at 20°C/min to 170°C for 15
min, 2°C/min to 180°C for 2 min, and at 30°C/min to 290°C and hold for 1.33 min.
4. Operate the detector in the phosphorous mode at 250°C.
3.8. Analysis of Extracts Using GC–Mass Spectrometric Detection
1. Inject 1 µL of cleaned SFE extract into a split/splitless injector containing a 4-mm id
deactivated single taper liner at 250°C with the split vent opening after 0.75 min.
2. Use helium as carrier gas with electronic pressure control to maintain a linear velocity of
about 27.5 cm/s.
3. Hold the column temperature at 100°C for 1 min, program at 25°C/min to 180°C for 2.1
min, 1°C/min to 190°C for 2.5 min, and at 25°C/min to 310°C and hold for 2.4 min.
4. Set the GC detector interface at 300°C and acquire data using selective ion monitoring to
collect from 3 to 12 ions in a timed window (see Note 15).
3.9. Identification and Calibration
Pesticides can be identified by analyzing a single pesticide in acetone (1 µg/mL or
higher) by GC/FPD or by GC–mass spectrometric detection (MSD) in full-scan mode
using a single pesticide in acetone (10 µg/mL or higher; see Note 16) and recording
retention times. The following calibration approach is suitable for the analysis of extracts using GC/FPD and GC–MSD. Use external standard calibration by bracketing
blank, spiked sample, and samples with four calibrant levels. Prepare the lowest
calibrant level equivalent to the required limit of quantitation. Choose a range of
calibrants that covers the range of residues to be determined. Typical range for an
initial run is 0.05–0.40 mg/kg (see Note 17).
4. Notes
1. A setting of 10 gives coarse powder/particles of which 99% passed through a 1-mm screen
for dry commodities with moisture contents less than 20%.
2. Extract sand using the SFE method prior to use to ensure there are no contaminants
present. If necessary, acid wash sand and recheck.
3. Any high-performance liquid chromatographic sorbent with particle size greater than 15
µm is suitable for use in the SFE sorbent trap.
4. SFE-grade CO2 is used to extract samples. Cheaper, industrial grade CO2 is suitable for
cryogenic cooling of the SFE trap. Store a full cylinder of each type of gas in the laboratory so they are at ambient temperature and ready for immediate use when replacing
empty cylinders.
5. Matrix-matched standards are prepared by adding, using microliter syringes, known
amounts of pesticides to sample extracts that contain the same matrix concentration as
samples. Calibrants prepared in this way protect analytes from degradation during GC
injection, thus ensuring consistent responses are obtained for calibrants, spiked recover-
316
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
Norman and Panton
ies, and samples. Sufficient blank extract for matrix-matched standards should be prepared in advance by extracting samples known not to contain pesticide residues.
Any commodities needed as blank material used for matrix-matched standards or spiking
must be checked before use by SFE and GC analysis. Organically grown commodities are
usually suitable for commodity blanks but must also be checked before use.
Clean the sample divider and mill between samples by brushing and then processing a
sample known not to contain pesticide residues and follow with further brushing.
It is not necessary to use a new trap for each sequence of eight sample extractions. Traps
should only be repacked if it is suspected that extracts contain excessive amounts of
coextractives.
Use the system check, which is a pressure drop test that automatically monitors leak
rates. The user is notified of any leaks exceeding acceptable ranges; then, the user should
leak test the SFE instrument and associated gas lines. Check gas lines and fittings for
large CO2 leaks, which will be seen as frosty deposits, and test for smaller leaks using 1%
soap solution. The use of a separate extraction thimble and end caps, which are not used
for samples, is recommended for the system check.
The mass of sample that can be loaded into an extraction thimble will vary depending on
the sample density and particle size. Care should be taken to avoid contamination of
extraction thimble/cap threads with sample or associated sample dust to ensure an effective seal is made.
Calculation of spiked recoveries gives an indication of how well the SFE unit is extracting and is a useful quality control tool. Do not use more than 100 µL solvent as this may
lead to leaching of analytes through the bottom of the extraction thimble. It is important
to allow the solvent to evaporate as any remaining solvent may act as a modifier, altering
the polarity and extraction efficiency of the supercritical CO2. A blank (i.e., a sample
known not to contain pesticide residues) can be included in an extraction sequence following the spiked blank to show there is no carryover of pesticide residues to subsequent
extractions if desired.
Avoid dependence on volumes of solvent dispensed by the SFE instrument trap as these
may not be accurate. Collect solutions and bring to a fixed volume.
Parafilm used to cover the borosilicate culture tube reduces solvent evaporation while
extracts are waiting SPE cleanup. It is not necessary to cover the collection vessels with
parafilm because of the lower volatility of the SPE eluant solvents.
Care is required to prevent extract reaching complete dryness, which is likely to lead to
the loss of more volatile pesticides such as dichlorvos and methacrifos.
Deterioration of chromatography, observed as peak broadening and change in detector
response during the analysis of a batch of samples, may be observed because of the accumulation of coextractives or fats in the injector liner or the first 30 cm of analytical column. It is advisable to change the injection port liner and to remove the first 30 cm of
analytical column following analytical runs of about 40 injections. Such a maintained
system is capable of detecting pesticides at levels of 0.05 mg/kg with a minimum signalto-noise ratio equal to 4 for the following OP pesticides: dichlorvos, methacrifos,
diazinon, etrimfos, phosphamidon, chlorpyrifos methyl, fenitrothion, pirimiphos methyl,
malathion, and chlorpyrifos ethyl. The extraction and cleanup technique is also suitable
for additional OP pesticides and pesticides of other classes, such as organochlorine and
synthetic pyrethroids.
For GC–MSD analysis, take a spectra of the pesticide peak and note its retention time.
Select the most appropriate ion to be used for quantitation and select two qualifying ions
Residues in Grain and Dried Foodstuffs
317
for each pesticide. Higher mass ions are most desirable, but also consider the abundance
of the ions to ensure the limit of quantitation is achieved. Selecting a higher mass ion will
limit any interference from commodity coextractives, some of which may coelute with
pesticides.
17. It is convenient to prepare calibrants using levels that increase by a factor of two; this also
facilitates interpretation of data. However, it may be more practical to use higher calibrant
levels if anticipating samples that may contain high residue levels or samples known to
contain residues at a higher level. The first and second set of calibrant response should
not deviate by more than 20% from the mean response of the sets of calibrants to ensure
accurate quantitation. If the response change is greater than 20%, it may be necessary to
change the injection port liner and remove the first 30 cm of column or to calibrate more
frequently.
References
1. Luke, M. A., Froberg, J. E., Doose, G. M., and Masumoto, H. T. (1981) Improved
multiresidue gas chromatographic determination of organophosphorus, organonitrogen,
and organohalogen pesticides in produce, using flame photometric and electrolytic conductivity detectors. J. Assoc. Off. Anal. Chem. 64, 1187–1195.
2. Bottomley, P. and Baker, P. G. (1984) Multiresidue determination of organochlorine, organophosphorus and synthetic pyrethroid pesticides in grain by gas–liquid and high performance chromatography. Analyst, 109, 85–90.
3. Norman, K. N. T. and Panton, S. W. (2001) Supercritical fluid extraction and quantitative
determination of organophosphorus pesticide residues in wheat and maize using gas chromatography with flame photometric and mass spectrometric detection. J. Chromatogr.
907, 247–255.
4. Valverde-García, A., Fernandez-Alba, A. R., Contreras, M., and Agüera, A. (1996)
Supercritical fluid extraction of pesticides from vegetables using anhydrous magnesium
sulfate for sample preparation. J. Agric. Food Chem. 44, 1780–1784.
5. Faugeron, J., Tourte, J., Gros P., Charabel S., and Cooper J. F. (1997) Extraction par fluide
supercritique de résidus de pesticides. Développement et validation d’une méthode
appliquée aux ceréales et à leurs dérivés. Analusis 25, 192–196.
6. Scopec, Z. V., Clark, R., Harvey, P. M. A., and Wells, R. J. (1993) Analysis of organophosphorus pesticides in rice by supercritical fluid extraction and quantitation using an
atomic emission detector. J. Chromatogr. Sci. 31, 445–449.
7. Kim, D. H., Heo, G. S., and Lee, D. W. (1998) Determination of organophosphorus pesticides in wheat flour by supercritical fluid extraction and gas chromatography with nitrogen-phosphorus detection. J. Chromatogr. A, 824, 63–70.
8. Wang, J. H., Xu, Q., and Jiao, K. (1998) Supercritical fluid extraction and off-line cleanup for the analysis of organochlorine pesticide residues in garlic. J. Chromatogr. A, 818,
138–143.
9. Anonymous. (1976) International Thermodynamic Tables of the Fluid State, Carbon Dioxide. Pergamon Press, Oxford, UK.
10. Fillion, J., Sauve, F., and Selwyn, J. (2000) Multiresidue method for the determination of
251 pesticides in fruits and vegetables by gas chromatography/mass spectrometry and liquid chromatography with fluorescence detection. J. Assoc. Off. Anal. Chem. 83, 698–713.
11. Chamberlain, S. J. (1990) Determination of multi-pesticide residues in cereals, cereal products and animal feeds using gel-permeation chromatography. Analyst, 115, 1161–1165.
Analysis of Dithiocarbamates in Food
319
25
Application of Microwave-Assisted Extraction
for the Analysis of Dithiocarbamates in Food Matrices
Euphemia Papadopoulou-Mourkidou, Emmanuil Nikolaos Papadakis,
and Zisis Vryzas
Summary
Microwave-assisted extraction (MAE) is a simple, fast, and accurate method developed for the analysis of N,N-dimethyldithiocarbamate (DMDTC) and ethylenebis(dithiobamate) (EBDTC) fungicides in fruits and vegetables. Residues are extracted from the
plant matrices and hydrolyzed to CS2 in a single step in the presence of 1.5% SnCl2 in 5N
hydrochloric acid using a laboratory microwave oven operated in the closed-vessel mode.
The evolved CS2, trapped in a layer of isooctane overlaying the reaction mixture, is
analyzed by gas chromatography/flame photometric detection (GC/FPD). Sets of 12
samples are processed simultaneously. Quantification is based on external standard calibration curves made with either standard solutions of individual DMDTCs (thiram,
ziram) or EBDTCs (maneb, zineb, mancozeb), which are processed as the field samples,
or using standard solutions of CS2 made in isooctane. Calibration curves are better fitted
with quadratic equations with correlation coefficients >0.999; however, good linear correlation coefficients can also be obtained in narrower calibration ranges. Limits of detection (LODs) and limits of quantitation (LOQs) are in the range 0.005–0.1 mg/kg.
Recoveries are >80%, with respective relative standard deviation values <20%.
Key Words: CS2; Dithiocarbamates; fruits and vegetables; fungicides; gas chromatographic analysis; microwave-assisted extraction (MAE); residues.
1. Introduction
Dithiocarbamate (DTC) fungicides are very important nonsystemic fungicides used
worldwide for the control of fungal and bacterial pathogens on tomatoes, grapes,
apples, peaches, tobacco, lettuce, and other fruit and vegetable crops. DTCs used as
plant protection products are divided into two subgroups: the N,N-dimethyldithiocarbamates (DMDTCs; thiram and ziram) and ethylenebis(dithiocarbamates) (EBDTCs;
maneb, zineb, and mancozeb).
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
319
320
Papadopoulou–Mourkidou, Papadakis, and Vryzas
Several methods have been published for the determination of DTC residues in
fruits and vegetables. Most of these methods are based on an initial acid hydrolysis
step of the DTCs in the presence of stannous chloride, as proposed by Keppel (1,2),
and subsequent analysis of the evolved CS2 by spectrophotometry (1,3) or gas chromatography (4–8). Methods employing a separation technique, such as high-performance liquid chromatography, prior to a spectophotometric-based technique for the
final qualitative and quantitative analysis of residues of individual members of the
DTCs have been also reported (9–12). However, it should be emphasized here that
maximum residue limits of DTCs in food are set collectively for the entire group of
fungicides expressed as carbon disulfide; thus, irrespective of the analytical approach
employed for their determination, residues are expressed in milligrams of carbon disulfide equivalents per kilogram of food.
Microwave-assisted extraction (MAE) techniques have been incorporated into
many residue methods developed for the analysis of pesticides in a variety of substrates (8,13–21) and offer advantages such as improved accuracy and precision,
reduced extraction time, low solvent consumption, and high level of automation compared to conventional extraction techniques (22–24). Such an MAE-based method for
the analysis of DTCs in tobacco and peaches has been published (8), and this method
as adapted for the analysis of DTCs in a variety of fresh fruits and vegetables is presented here.
Briefly, DTCs are subjected to acid hydrolysis in the presence of stannous chloride
in an MAE system. The evolved CS2 trapped in an overlaying isooctane layer is subjected to gas chromatographic analysis for qualitative and quantitative determinations.
Sets of 12 samples are processed simultaneously. Two DTC fungicides were selected
for method validation: thiram (a DMDTC) and mancozeb (an EBDTC). The selected
commodities for method validation were apples, green beans, and peaches for thiram
and potatoes and tomatoes and green peppers for mancozeb. Two additional commodities representing low-moisture processed foods containing fruits and vegetables were
analyzed for mancozeb (baby fruit cream powder and dehydrated vegetable cubes).
2. Materials
1.
2.
3.
4.
5.
6.
7.
8.
Professional analysis-grade isooctane.
Hydrolysis solution of 1.5% stannous (II) chloride in 5M HCl , freshly prepared daily.
Mancozeb diluent of 0.2 M ethylenediaminetetraacetic acid and 0.4 M NaOH.
Microwave extraction system (e.g., MSP 1000, CEM, Matthews, NC) equipped with
polytetrafluoroethylene-lined extraction vessels (see Note 1).
Gas chromatograph equipped with an FPD detector operated in the sulfur mode, split/
splitless injector, and an autosampler (optional).
Chromatographic column 10 m × 0.53 mm (20 µm film thickness) with a 2.5-m particle
trap (e.g., PORAPLOT Q column, Varian Analytical Instruments, The Netherlands).
Thiram stock and calibration solutions: Prepare a stock solution of 20 µg/mL in acetone
(stable at –18°C for 5 days); dilute appropriately to produce calibration standards of 10,
5, 1, and 0.5 µg/mL.
Mancozeb stock and calibration solutions: Prepare a stock solution of 20 µg/mL in
mancozeb diluent (use only freshly prepared solutions); dilute appropriately to produce
calibration standards of 10, 5, 1, and 0.5 µg/mL.
Analysis of Dithiocarbamates in Food
321
Table 1
Operational Parameters of Microwave Oven
Magnetron power (W)
Maximum temperature (°C)
Maximum pressure (psi)
Time the system remains at above conditions (min)
Weight of sample (g)
Number of vessels
800
100
120
25
10 for wet tissues
2 for dry tissues
12
9. CS2 stock and calibration solutions: Prepare a stock solution of 1 mg/mL in isooctane;
dilute appropriately to produce calibration standards of 0.05, 0.1, 0.5, 1, 5, and 10 µg/mL
in isooctane (store at –18°C).
3. Methods
The methods presented deal with (1) safety and sample pretreatment, (2) the preparation of samples and calibration standards, (3) the chromatographic determination,
and (4) the results.
3.1. Initial Considerations
3.1.1. Safety Precautions
Because of the handling of strong acid solutions and the fact that some of the DTCs
are suspected carcinogens, all operations should be performed in a well-ventilated
fume hood with the analyst wearing protective gloves.
3.1.2. Sample Pretreatment
1. Take a representative portion of the commodity to be analyzed.
2. If the sample is to be analyzed on the same day, homogenize it in a food processor at low
speed. Immediately transfer the appropriate sample weight into the extraction vessels.
3. If the sample is to be analyzed on another occasion, keep the intact sample in a freezer
(–18°C) (see Note 2).
3.2. Preparation of Samples and Calibration Standards
3.2.1. Sample Preparation
1. Weigh 10-g portions of sample (2 g in the case of low-moisture products) and transfer
them into the sample vessels.
2. Add 10 mL isooctane and 30 mL hydrolysis solution.
3. Seal the vessels and shake them vigorously for approx 30 s (see Note 3).
4. Place the vessels into the MAE system.
5. Program the MAE system by entering the values depicted in Table 1 (see Note 4).
6. Start the extraction.
7. When the extraction period is over, carefully remove the hot vessels from the MAE system, shake them for another 30-s period, and place them in an ice bath.
8. Monitor the temperature of the vessels at regular intervals by inserting the temperature
probe into the control vessel.
322
Papadopoulou–Mourkidou, Papadakis, and Vryzas
Table 2
Preparation of Calibration Solutions to Construct a 10-Point Calibration
Curve for Either DTC
Calibration
level
1
2
3
4
5
6
7
8
9
10
Amount (µg)
of pesticide added
to each vessel
Volume (mL)
of calibration
solution transferred
to each vessel
0.1
0.25
0.5
1
2.5
5
10
20
40
50
0.2
0.5
1
1
0.5
1
1
1
2
2.5
Calibration solutions
(µg/mL)
0.5
0.5
0.5
1
5
5
10
20
20
20
9. Shake the vessels for 30 s when the temperature is in the range 50–60°C
10. When the temperature of the control vessel has reached 35°C, the sample vessels can be
removed from the ice bath.
11. Carefully open the vessels and with the help of a glass Pasteur pipet transfer an aliquot of
the isooctane phase into an autosampler vial (or other appropriate container). Seal the vial
tightly to avoid carbon disulfide loss.
3.2.2. Preparation of Calibration Standards
Calibration curves are prepared by processing calibration standard solutions of either
fungicide in the same manner as for the samples. To construct a 10-point calibration
curve, pipet the appropriate volume of each calibration solution, as specified in Table 2,
into each MAE vessel. Follow steps 2–10 of the Subheading 3.2.1. (see Note 5).
3.2.3. Preparation of Fortified Samples
Fortified samples are prepared by spiking DTC–free portions of each commodity
with appropriate volumes of thiram or mancozeb calibration solutions. After spiking,
handle samples as described in steps 2–10 of Subheading 3.2.1.
3.3. Gas Chromatography
3.3.1. Operational Conditions
Gas chromatographic analysis of carbon disulfide is carried out on a styrene–
divinylbenzene copolymer porous column (see Note 6).
1. Use helium (99.999% pure) as a carrier gas at a constant linear velocity of 35 cm/s and
nitrogen as makeup gas for the FPD at a flow rate of 30 mL/min. Also, set the air and
hydrogen flow at 150 and 100 mL/min, respectively.
Analysis of Dithiocarbamates in Food
323
Table 3
Temperature Zones of Gas Chromatograph
Injector temperature
Detector temperature
Oven program
120°C
200°C
40–130°C at 8°C/min
130–160°C at 10°C/min
Hold at 160°C for 3 min
2.
3.
4.
5.
6.
Program chromatograph temperature zones according to Table 3.
Set the detector in square root output mode (if applicable) (see Note 7).
Operate the split/splitless injector in the splitless mode.
Set the split valve to close 12 s prior to run start and to open 45 s after run start.
Use septum purge flow of about 0.5 mL/min and surge pressure of 2 psi from 4.8 s to 48
s after run start to ensure quick entry of carbon disulfide into the column.
7. Set the injection volume to 6 µL.
8. Start injection sequence.
3.3.2. Routine Sample Analysis
With every batch of samples, a blank run, three injections of a 10-µg/mL carbon
disulfide standard solution and an injection of isooctane, should be performed to ensure
acceptable retention time repeatability and sensitivity. A new calibration curve must
be prepared each time a significant change in the sensitivity of the system is observed.
3.4. Results
3.4.1. Calibration Curves and Calculations
1. Construct calibration curves for each fungicide by plotting peak areas against the respective amount (micrograms) of fungicide added to each vessel.
2. Calculate the amount found for each pesticide, in micrograms, by referring to the appropriate calibration curve.
3. Report residue value by applying the following formula:
Residue (µg/g) = µg from calibration curve/Sample amount in g
Sample calibration curves for carbon disulfide, thiram, and mancozeb are shown in
Figs. 1–3. Calibration curves are better described by quadratic equations with correlation coefficients above 0.999. Good linear correlation coefficients (r2 = 0.999) between
concentrations and peak areas are also found at narrower concentration ranges (see
Note 8).
Alternatively, results can be reported in micrograms CS2 per gram of commodity.
Calibration solutions of carbon disulfide are directly injected into the chromatographic
system, and a calibration curve is constructed by plotting peak areas against respective
concentrations (micrograms per microliter) of the carbon disulfide standard solutions
injected. Results are calculated by the following formula:
CS2 (µg/g) = 10 mL × (µg/mL CS2 from calibration curve)/Sample amount (g)
324
Papadopoulou–Mourkidou, Papadakis, and Vryzas
Fig. 1. Sample calibration curve for carbon disulfide.
Fig. 2. Sample calibration curve for thiram.
3.4.2. Method Validation
The efficiency of the method is evaluated at regular intervals. This is performed by
analyzing fortified samples of each commodity. When a new commodity is analyzed
for the first time, recovery studies are performed to determine percentage recoveries in
at least three fortification levels and establish respective LOD and LOQ values. In
routine analysis, usually a single fortification level is adequate (see Note 9).
Analysis of Dithiocarbamates in Food
325
Fig. 3. Sample calibration curve for mancozeb.
Typical recovery values for thiram and mancozeb at three fortification levels, respectively, and for different commodities are given in Table 4. For all commodities,
limits of detection (LODs) values are set at 0.005 µg/g for thiram and 0.01 µg/g for
mancozeb. For thiram, limits of quantitation (LOQ) values of 0.01, 0.05, and 0.05 are
determined for peach, green bean, and apple, respectively, whereas for mancozeb,
LOQ values of 0.01 (tomato), 0.05 (potato, fruit cream powder, dehydrated vegetable
cube), and 0.1 (green pepper) are obtained. Sample chromatograms are shown in Figs.
4 and 5 (see Note 10).
4. Notes
1. Because the solvents used are mutually immiscible, sample particles tend to accumulate
in the interface of the two layers; thus, contamination buildup is observed inside the vessel, especially when analyzing dry tissues. When this happens, it is possible to observe
electric sparks inside the vessels, which could in extreme cases destroy the vessels. To
avoid this, all vessels must be scrupulously cleaned with hot detergent solution and scrubbing after each extraction. In case of excess contamination buildup, the vessels can be
cleaned with concentrated nitric acid after consulting the manufacturer.
2. Although it has been reported that DTC breakdown begins when residues are exposed to
tissue juice, this seems to be a problem in methods in which the analysis of intact fungicide molecules is required (7,9). However, it is advisable to proceed with sample preparation without undue delay. For tissues with high water content, they could be placed in the
freezer and homogenized when partially frozen.
3. The vigorous shaking of the vessels facilitates tissue moistening, especially in the case of
dry tissues; thus, sample accumulation in the interface is minimized.
4. The microwave system must be programmed to heat samples providing the maximum
allowable energy at all times until the predetermined settings have been reached. This
feature is called standard control in the specific instrument.
326
Thiram
326
Fortification level (µg/g)
Peach
0.5
1
5
90 (11)
100 (2)
85 (6)
Mancozeb
Green bean
Apple
Tomato
Green pepper
Potato
103 (7)
98 (5)
100 (1)
92 (3)
105 (3)
95 (2)
110 (3)
113 (2)
87 (4)
94 (1)
98 (2)
95 (2)
85 (3)
93 (6)
97 (1)
Fruit cream
powder
81 (5)
95 (4)
94 (1)
Dehydrated
vegetable cube
83 (8)
82 (9)
93 (3)
Papadopoulou–Mourkidou, Papadakis, and Vryzas
Table 4
Method Validation Data: Recoveries and Respective (Relative Standard Deviation) Values of the Selected DTCs
in Fruits and Vegetables
Analysis of Dithiocarbamates in Food
327
Fig. 4. Sample chromatogram from the analysis of a potato sample fortified with mancozeb
at the 0.05-µg/g level.
Fig. 5. Sample chromatogram from the analysis of an apple sample fortified with thiram at
the 0.05-µg/g level.
5. Although visualization between the two phases is easy in the case of samples, it can be
quite difficult to do when constructing a calibration curve; thus, there is a danger of taking up acidic reaction mixture along with isooctane. Also, avoid purging with air when
transferring the sample with the Pasteur pipet into the autosample vials, or carbon disulfide loss may occur.
6. Porous layer open tubular (PLOT) columns are recommended for the analysis of solvents
and volatile compounds such as CS2, although traditional packed columns may also be
used if carbon disulfide can be resolved from isooctane. The new type of bonded PLOT
328
7.
8.
9.
10.
Papadopoulou–Mourkidou, Papadakis, and Vryzas
columns promises many advantages compared to nonbonded predecessors, but they must
be tested for the specific use. PLOT columns must be handled with extreme caution during installation and operation to avoid bed channeling.
When the FPD is operated in the sulfur mode, sulfur is detected as S2, and the response is
proportional to the square of the concentration of the sulfur-containing compound. When
the square root output mode is selected, the detector’s electrometer output is modified to
correct for the nonlinear relationship between the detector output current and sulfur concentration. This feature is not applicable to all instruments.
When analyzing samples with residues near the LOQ levels, more accurate results can be
obtained by constructing a calibration curve of only calibration points near the residue level.
The LOD is determined as the lowest concentration of the fungicide giving a signal-tonoise ratio of 3. The LOQ is determined as the lowest concentration of the fungicide
giving a response that can be quantified with a relative standard deviation below 20%.
Except from the CS2 and isooctane peaks, in some commodities peaks corresponding to
other sulfur-containing compounds (mercaptans, hydrogen sulfide) appear in the chromatogram. In some instances, a compound with a retention time similar to carbon disulfide elutes from the column, and although it can be adequately resolved later, loss of
column efficiency because of contamination from sample compounds can result in quantification errors. Also, loss of resolution between CS2 and isooctane peaks can be observed because of column contamination.
References
1. Keppel, G. E. (1969) Modification of the carbon disulfide evolution method for dithiocarbamate residues. J. AOAC 52, 162–167.
2. Keppel, G. E. (1971) Collaborative study of the determination of dithiocarbamate residues
by a modified carbon disulfide evolution method. J. AOAC 54, 528–532.
3. Kesari, R. and Gupta, V. K. (1998) A sensitive spectrophotometric method for the determination of dithiocarbamate fungicide and its application in environmental samples.
Talanta 45, 1097–1102.
4. Ahmad, N., Guo, L., Mandarakas, P., and Appleby, S. (1995) Determination of dithiocarbamate and its breakdown product ethylenethiourea in fruits and vegetables. J. AOAC Int.
78, 1238–1243.
5. Woodrow, J. E. and Seiber, J. N. (1995) Analytical method for the dithiocarbamate fungicides ziram and mancozeb in air: Preliminary field results. J. Agric. Food Chem. 43, 1524–
1529.
6. Ahmad, N., Guo, L., Mandarakas, P., Farah, V., Appleby, S., and Gibson, T. (1996)
Headspace gas–liquid chromatographic determination of dithiocarbamate residues in fruits
and vegetables with confirmation by conversion to ethylenethiourea. J. AOAC Int. 79,
1417–1422.
7. Royer, A., Ménand, M., Grimault, A., and Communal, P. Y. (2001) Development of automated headspace gas chromatography determination of dithiocarbamates in plant matrixes.
J. Agric. Food Chem. 49, 2152–2158.
8. Vryzas, Z., Papadakis, E. N., and Papadopoulou–Mourkidou, E. (2002) Microwave–Assisted Extraction (MAE)–acid hydrolysis of dithiocarbamates for trace analysis in tobacco
and peaches. J. Agric. Food Chem. 50, 2220–2226.
9. Gustafsson, K. H. and Fahlgren, C. (1983) Determination of dithiocarbamate fungicides in
vegetable foodstuffs by high–performance liquid chromatography. J. Agric. Food Chem.
31, 461–463.
Analysis of Dithiocarbamates in Food
329
10. Ekroth, S. B., Ohlin, B., and Österdahl, B.-G. (1998) Rapid and simple method for determination of thiram in fruits and vegetables with high-performance liquid chromatography
with ultraviolet detection. J. Agric. Food Chem. 46, 5302–5304.
11. Lo, C.-C., Ho, M.-H., and Hung, M.-D. (1996) Use of high–performance liquid chromatography and atomic absorption methods to distinguish propineb, zineb, maneb, and
mancozeb fungicides. J. Agric. Food Chem. 44, 2720–2723.
12. Weissmahr, K. W., Houghton, C. L., and Sediak, D. L. (1998) Analysis of the dithiocarbamate fungicides ziram, maneb, and zineb and the flotation agent ethylxanthogenate by
ion–pair reversed–phase HPLC. Anal. Chem. 70, 4800–4804.
13. Steinheimer, T. R. (1993) HPLC determination of atrazine and principal degradates in
agricultural soils and associated surface and ground water. J. Agric. Food Chem. 41, 588–595.
14. Molins, C., Hogendoorn, E.A., Heusinkveld, H. A. G., van Harten, D. C., van Zoonen, P.,
and Baumann, R.A. (1996) Microwave assisted solvent extraction for the efficient determination of triazines in soil samples with aged residues. Chromatographia 43, 527–532.
15. Hoogerbrugge, R., Molins, C., and Baumann, R. A. (1997) Effects of parameters on
microwave assisted extraction of triazines from soil: evaluation of an optimization trajectory. Anal. Chim. Acta 348, 247–253.
16. Xiong, G., Liang, J., Zou, S., and Zhang, Z. (1998) Microwave–assisted extraction of
atrazine from soil followed by rapid detection using commercial ELISA kit. Anal. Chim.
Acta 371, 97–103.
17. Papadakis, E. N. and Papadopoulou–Mourkidou, E. (2002) Determination of metribuzin
and major conversion products in soils by microwave-assisted water extraction followed
by liquid chromatographic analysis of extracts. J. Chromatogr. A 962, 9–20.
18. Vryzas, Z. and Papadopoulou-Mourkidou, E. (2002) Determination of triazine and
chloroacetanilide herbicides in soils by microwave-assisted extraction (MAE) coupled to
gas chromatographic analysis with either GC-NPD or GC-MS. J. Agric. Food Chem. 50,
5026–5033.
19. Molins, C., Hogendoorn, E. A., Dijkman, E., Heusinkveld, H. A. G., and Baumann, R. A.
(2000) Determination of linuron and related compounds in soil by microwave–assisted
solvent extraction and reversed–phase liquid chromatography with UV detection. J.
Chromatogr. A 869, 487–496.
20. Hogendoorn, E. A., Huls, R., Dijkman, E., and Hoogerbrugge, R. (2001) Microwave
assisted solvent extraction and coupled–column reversed–phase liquid chromatography
with UV detection–Use of an analytical restricted–access–medium column for the efficient multi–residue analysis of acidic pesticides in soils. J. Chromatogr. A 938, 23–33.
21. Patsias, J., Papadakis, E. N., and Papadopoulou–Mourkidou, E. (2002) Analysis of
phenoxyalkanoic acid herbicides and their phenolic conversion products in soil by microwave assisted solvent extraction and subsequent analysis of extracts by on–line solid–
phase extraction–liquid chromatography. J. Chromatogr. A 959, 153–161.
22. Eskilsson, C. S. and Björklund, E. (2000) Analytical–scale microwave–assisted extraction. J. Chromatogr. A 902, 227–250.
23. Buldini, P. L., Ricci, L., and Sharma, J. L. (2002) Recent applications of sample preparation techniques in food analysis. J. Chromatogr. A 975, 47–70.
24. Camel, V. (2000) Microwave–assisted solvent extraction of environmental samples.
Trends Anal. Chem. 19, 229–248.
α-Hexachlorocyclohexane in Food
331
26
Enantioselective Determination of α-Hexachlorocyclohexane
in Food Samples by GC–MS
Chia-Swee Hong and Shaogang Chu
Summary
A method for the determination of individual α-hexachlorocyclohexane (α-HCH)
enantiomers is described. The method consists of ultrasonic extraction, sulfuric acidmodified silica gel cleanup, fractionation on a polar silica solid-phase extraction (SPE)
column, and final determination by gas chromatography/electron capture negative ion
mass spectrometry (GC–MS/ECNI) on a Chirasil-Dex column. The MS is operated in
selected ion monitoring mode. Racemic α-HCH is used as the calibration standard, and
ε-HCH is used as the surrogate internal standard. Each α-HCH enantiomer is quantitated
by the relative response factor method using the m/z 255 ion. The enantiomeric ratio
(ER) is obtained as the area ratio of the (+)/(−) peaks eluting from the cyclodextrin column. ER determinations are important because enantiomers differ considerably in how
they accumulate in organisms and decompose in the environment. This method provides
a simple and useful tool to monitor the enantioselectivity of α-HCH in food samples.
Key Words: Chiral; food; GC; α-HCH; MS; SPE.
1. Introduction
Hexachlorocyclohexane (HCH) has been used as a pesticide since 1942, when the
insecticidal properties of the γ-isomer were discovered. Technical HCH has an
approximate composition of 60–70% α-HCH, 5–12% β-HCH, 10–15% γ-HCH, and
minor percentages of other isomers; it is a widely used organochlorine compound and
is found all over the world (1–4). Although γ-HCH is the isomer with the dominant
insecticidal properties, the other isomers also have toxic properties (4). The technical
mixture was banned in the United States and Canada in 1978 and 1971, respectively,
but is still used in some developing countries.
α-HCH is easily transported via the atmosphere, and it has contaminated all environmental matrices, even those distant from sources (4). α-HCH is the only chiral
HCH isomer and exists as two structurally distinct, mirror images called enantiomers
(Fig. 1) on the basis of a lack of axial symmetry. Enantiomers have identical physical
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
331
332
Hong and Chu
Fig. 1. Enantiomers of α-HCH.
properties and are designated as either (+) or (−) corresponding to their ability to rotate
a plane of polarized light. The chiral compound is released into the environment as a
racemic mixture (5); however, the enantiomers may exhibit enantiomer-specific biological and toxicological characteristics (6,7). Thus, the determination of enantiomeric
ratios (ERs) or enantiomeric fractions (EFs) of chiral compounds can be used to assess
the potential stereoselectivity of biotransformation pathways and enantiomer-specific
biological activity because these processes may affect the relative accumulation of
chiral compounds in biota. The ER (+/−) of α-HCH has been measured in many environmental samples, and different ratios have been observed in samples taken from air,
water, fish, birds, and sea mammals (6,8–11).
The determination of ERs of organochlorines by high-resolution gas chromatography became possible with the introduction of suitable chiral stationary phases (CSPs)
a decade ago. Since then, a number of CSPs with modified cyclodextrins have been
applied for the enantiomeric separation of chiral organochlorines (12–14).
This chapter describes a method for determining the α-HCH enantiomers in food
samples by gas chromatography/electron capture negative ion mass spectrometry (GC–
MS/ECNI) (12,15,16) using a commercially available, modified cyclodextrin GC column.
2. Materials
1. (a) α-HCH standard; (b) a surrogate internal standard (ε-HCH; Ultra Scientific,
Kingstown, RI; see Note 1).
2. Organic solvents (hexane, acetone, dichloromethane, methanol, isooctane) certified for
ultratrace analyses or pesticide residue trace analyses.
3. Concentrated H2SO4 analytical reagent.
4. A food processor/blender or tissuemizer.
5. Ultrahigh-purity helium and methane (minimum purity 99.999%) for GC–MS/ECNI
analysis; prepurified nitrogen (minimum purity 99.995%) for solvent evaporation after
extraction, before fractionation, and before GC analysis.
6. Analytical balances (Ohaus, Florham, NJ; see Note 2).
7. Anhydrous sodium sulfate (see Note 3).
8. Sorvall RC-3 automatic refrigerated centrifuge, HL-8 rotor with 100-mL bucket.
9. Empty solid-phase extraction (SPE) reservoirs (20 mL) with frits (20-µm pore size)
(Varian Inc., Walnut Creek, CA).
α-Hexachlorocyclohexane in Food
333
10. Silica gel (Aldrich; 70–230 mesh).
11. Polar silica SPE columns (Bond Elut straight-barrel columns, 40-µm particle size), 500
mg sorbent mass, 3-mL volume (Varian).
12. Kuderna-Danish (K-D) evaporator with 125-mL capacity fitted with Snyder column and
12-mL volumetric receiving tube, Kontes Glass Co.
13. Ultrasonic processor with titanium probe.
14. Agilent 6890 GC equipped with a programmed temperature vaporizing (PTV) injector
and 5973 quadrupole mass spectrometer operated in ECNI mode (see Note 4); ChirasilDex column (Chrompack, Raritan, NJ; 25 m × 0.25 mm id and 0.25-µm film thickness;
see Note 5) with immobilized permethyl 2,3,6-tri-O-methyl β-cyclodextrin on a
polysiloxane backbone as the stationary phase.
15. A 3-m long retention gap with 0.25-mm id (Agilent Technologies, Palo Alto, CA; see
Note 6).
16. 2-mL GC vials equipped with plastic screw caps and Teflon-lined septa.
3. Methods
3.1. Preparation of Standard Solutions (see Note 7)
1. Prepare stock solution A of standard α-HCH in isooctane (1 mg/mL) and a separate solution B of ε-HCH (1 mg/mL) in isooctane to be used as a surrogate internal standard.
2. Make a 1:10 dilution with isooctane to obtain the working solution.
3. Prepare the standard solution by adding 100 µL each of A and B work solutions to a 100mL volumetric flask. Bring to volume with isooctane.
3.2. Sample Extraction
1. Homogenize the food sample (meat, fish fillet, egg) in a food processor/blender or with a
tissuemizer.
2. Weigh 2–5 g of homogenized food sample (biological tissue) directly into a 100-mL centrifuge bottle on a top-loading balance.
3. Add 20 g of anhydrous sodium sulfate in a 100-mL centrifuge bottle, mix well with
spatula. For egg samples, weigh 2–5 g of homogenized sample directly into a 100-mL
centrifuge bottle, add 3 mL methanol, shake well, and let sit for 20 min before adding 20
g of anhydrous sodium sulfate.
4. Spike the sample with 100 µL surrogate internal standard (100 µg/mL).
5. Extract with 30 mL of 1:1 hexane:acetone by sonication for 5 min and then centrifuge at
1699g for 10 min (see Note 8).
6. Repeat step 5 twice more, combining extracts.
3.3. Lipid Determination
1. Accurately measure the extract volume and remove 10 mL of extract to a preweighed and
labeled test tube.
2. Evaporate the solvent by a gentle stream of nitrogen and then completely dry in oven at
105°C overnight.
3. Cool to ambient temperature and weigh the residue accurately on an analytical balance.
3.4. Evaporation
1. Transfer the remaining extract into a 125-mL K-D flask with 12-mL receiving tube.
2. Add small boiling chip to sample and concentrate the extracts to 6–8 mL using a threeball Snyder column on a steam bath.
334
Hong and Chu
3. Rinse Snyder column twice with hexane; when dry, remove Snyder column and flask. Put
Vigreaux column onto 12-mL receiving tube. Concentrate to approx 4 mL, rinse Vigreaux
column twice with hexane, remove column, and continue concentrating to 0.5 mL with a
gentle stream of nitrogen. Solvent exchange into hexane (see Note 9).
3.5. Lipid Removal
3.5.1. Preparation of 50% Sulfuric Acid on Silica
1. Rinse silica gel with consecutive methanol and dichloromethane.
2. Air-dry the dichloromethane-saturated material in the fume hood and then in an oven at
180°C for 3 h.
3. Cool and place in an appropriate size glass bottle.
4. Add sufficient concentrated sulfuric acid directly to the silica to yield an acid concentration of 50% based on total weight.
5. Shake manually until no clumping can be observed and store in a desiccator over phosphorous pentoxide until use. Caution: This reagent retains all of the properties of concentrated sulfuric acid and should be handled accordingly.
3.5.2. Acid-Modified Silica Cleanup (see Note 10)
1. Place 8 g acid-modified silica gel into an empty SPE column with a frit on the bottom.
Settle the silica gel by tapping.
2. Quantitatively transfer the sample extract to the column (add the rinses).
3. Elute with 30 mL hexane and collect the eluate.
4. Concentrate to 0.5 mL as described in Subheading 3.4.
3.6. SPE Cleanup and Fractionation (see Note 11)
1. Preelute the polar silica SPE column (prepacked SPE tubes) with 5 mL hexane. Discard
the eluate. Just before exposing the top frit to air, stop the flow.
2. Quantitatively transfer the concentrated extract to the column.
3. Elute with 10 mL hexane, discard the first 3 mL (contains most of the polychlorinated
biphenyls [PCBs] and some pesticides) and collect 5 mL of the eluate, which contains the
HCH isomers.
4. Reduce the eluate to near dryness with a gentle stream of nitrogen and reconstitute in 100
µL isooctane.
5. Transfer to a 150-µL glass insert in GC vial for the following GC–MS determination.
3.7. Gas Chromatography–Mass Spectrometry
1. Inject 25 µL (multiple injection, 5 × 5 µL) of sample with a large-volume PTV injector
(see Note 12). The parameters for the injection are as follows: 60°C initial temperature,
hold for 1 min, then increase to 300°C at 600°C/min. The vent time is 0.9 min, and the
purge time is 2.5 min. The column temperature is held at 60°C for 3 min, ramped to
140°C at 10°C/min, ramped to a final temperature of 190°C at 5°C/min, and held at 190°C
for 45 min, for a total analysis time of 66 min (see Note 13). The MS ion source is held at
250°C, and the quadrupoles are held at 150°C. Methane is used as the reagent gas and
perfluoro-5,8-dimethyl-3,6,9-trioxadodecane is used as the calibrant.
2. In selected ion monitoring (SIM) mode, record the ions at m/z 253 and m/z 255 and use
ion at m/z 255 for quantitation and ion at m/z 253 for qualification. In addition to retention
time, use relative intensities of the monitored ions for identification (require to be within
10% of standard values).
α-Hexachlorocyclohexane in Food
335
Fig. 2. ECNI–selected ion monitoring chromatograms (m/z at 255) showing elution of αHCH on the Chirasil-Dex column in (A) a standard and (B) a chicken egg sample.
3. Run a hexane solvent blank prior to analyzing standards (see Note 14) and samples (Fig. 2).
4. Calculate the ER (see Note 15) as the area ratio of the (+)/(−) peaks eluting from the
cyclodextrin column.
5. Calculate the individual enantiomer by the following equation:
(+)-α-HCH or (−)-α-HCH concentration, ng/g = (ACFG)/(BEDW)
where the symbols are defined as follows: A is the peak area of (+)-α-HCH or (−)-α-HCH
in the sample; B is the peak area of (+)-α-HCH or (−)-α-HCH in the standard; C is half of
the concentration of the racemic α-HCH standard (nanograms per milliliter); W is the
initial sample weight (grams); D is the peak area of the internal standard (ε-HCH) in the
sample at m/z 255; E is the concentration of the internal standard (ε-HCH) in the standard
solution (nanograms per milliliter); F is the peak area of the internal standard (ε-HCH) in
the standard solution at m/z 255; and G is the weight of internal standard (ε-HCH) added
to the sample (nanograms).
The recovery (R) of the internal standard (ε-HCH) is:
R = [(EDU)/(FG)] × [V/(V–10)] × 100%
336
Hong and Chu
where U is the final volume of the sample for GC–MS analysis (milliliters) and V is the
volume of the sample extract before taking 10 mL for lipid determination (milliliters).
3.8. Quality Control
The following limits are set for a positive identification: (1) agreement of ER values at m/z 255 and 253 should be within ±5%, (2) the area ratios of the monitored ions
for samples and standards should be within ±10%, and (3) the GC retention time should
be within ±1% compared to a reference standard. α-HCH is manufactured as a racemic mixture of the two enantiomers. If no metabolism occurs, the ERs of α-HCH
should be 1.00 (see Note 16). Replicate (n = 3) injections of analytical standards yields
racemic ER values with a standard deviation of ±0.02, demonstrating that chiral phase
GC–MS is capable of highly precise enantiomeric analysis (Fig. 2A). Average ERs
are calculated from replicate injections of two or more separately extracted portions of
the food sample, and standard deviations are calculated. All ERs meeting these requirements are considered reliable and are normalized by dividing by the average ER
of the racemic standards for a given set of samples. This removes any bias that the
column or instrument may introduce. To determine whether matrix effects alter the
ERs, a control sample is spiked with racemic α-HCH standard. The ERs for the extracted spiked α-HCH should also be racemic if there is no matrix effect. If the sum of
enantiomers determined on an achiral column is known, the concentrations of the (+)
and (−) enantiomers can be calculated from the ERs.
For quantitative analysis, the samples are spiked with the surrogate internal standard of ε-HCH prior to extraction to assess the efficacy of the technique and to account for
procedurally related analyte losses. Surrogate recoveries must fall between 60 and 120%.
With each set of six samples, a matrix spike and a matrix blank are also extracted.
All quality control samples undergo the same cleanup procedure as the samples. The
matrix spike contains a known amount of the target analyte at a concentration similar
to that expected in the samples. Spike recoveries must range between 60 and 120%.
4. Notes
1. ε-HCH, a minor component in the technical HCH mixtures and not commonly observed
in biological samples, was used as surrogate internal standard during development of this
method. ε-HCH is consistently baseline resolved in the presence of native pesticides during GC. PCBs 30, 65, and 204; δ-HCH; and perdeuterated α-HCH have been used by
other research groups as internal standards and are potentially suitable, provided that the
chosen standard is also absent from commercial Aroclor mixtures or technical HCH mixtures and thus does not occur in environmental samples. However, because most PCBs
are eluted in the first 3-mL fraction (which is discarded) of the SPE fractionation step and
are only partially recovered in the HCH fraction, they will not be suitable as surrogate
internal standards in this method.
2. Balances are required that are capable of weighing neat standards (milligrams), sample
material (grams), and centrifuge bottles (>100 g). Two balances are used for this work,
one high weight range for sample and extraction vessel weighing and the other for
standard(s) preparation.
3. It is recommended that only 10- to 60-mesh or similar granular sodium sulfate be used
because some analytes can be adsorbed onto the powdered material. Also, it is important
α-Hexachlorocyclohexane in Food
4.
5.
6.
7.
8.
9.
10.
337
that this material be contaminant free, so it should be purchased as pesticide residue grade
in glass containers or baked in a muffle furnace if purchased in bulk packages, for which
exposure to plastic is an issue. Sodium sulfate must be treated as follows: Place it in a
porcelain evaporating dish in a muffle furnace at 600°C for a minimum of 6 h; next, place
it into a glass container while still hot (< 60°C) and seal with a Teflon®-lined cap to
prevent the material from readsorbing contaminants from the atmosphere.
α-HCH enantiomers are present in samples at particularly low levels and in a complex
mixture. Use of a highly selective detection technique, either GC/ECD or GC–MS/SIM,
is mandatory. If injections of different concentrations of samples lead to variations in the
ERs caused by interferents, MS will be a better detection method than ECD because the
interferents have different m/z values that are not recorded by the MS/SIM. For this work,
GC–MS/ECNI has been used. Numerous studies have shown the applicability of GC–
MS/electron impact or ECNI to α-HCH enantiomer analysis as well (7,9,17–22).
At present, permethylated β-cyclodextrin seems to be the phase of choice for the enantiomeric separation of α-HCH in biological samples. This type of column is commercially
available from a number of manufacturers. The immobilized permethylated cyclodextrins
of the Chirasil-Dex type have the advantages of solvent compatibility, resistance to temperature shock, and longevity. Usually, columns more than 30 m long are not recommended which may lead to extended retention times.
Prefacing the coated separation column with a section of uncoated but deactivated fused
silica tubing can limit contamination of the separation column (nonvolatile residues tend
to accumulate in the “guard column”). “Press-fit” connectors offer convenient low thermal mass fittings that, properly installed, can be highly dependable. Tubing ends should
be freshly cut square, wiped with an acetone- or methanol-wetted tissue to remove any
fragments, and examined under suitable magnification. When chromatographic peaks start
to tail or are otherwise bad, about 30 cm can be cut from the beginning of the retention
gap to restore good peak shapes. This can be done only two or three times before needing
to change to a completely new retention gap.
Standards can be prepared from neat standards or by serial dilution of commercially prepared standards. All standards should be prepared in clean, solvent-rinsed volumetric
glassware and stored in a freezer when not in use.
Soxhlet and ultrasonic extraction are the most common extraction techniques for the
semivolatile compounds in solid samples. Sonication is a faster technique but requires
constant operator attention. In both techniques, problems usually are caused by contaminated reagents (especially sodium sulfate) or poor laboratory practice when transferring
sample extracts. The sample must be mixed with the sodium sulfate to achieve a sandy
consistency prior to solvent addition.
It is critical that all extracts be reduced to as small a volume as possible before reconstitution in hexane since any residual acetone will affect separation in the next cleanup step.
If the solvent (acetone/hexane) does not exchange to hexane after extraction, the remaining acetone in the extract will render the subsequent cleanup process irreproducible; also, the
eluate from acid-modified silica becomes yellow, which may result in interferences in GC.
Because sulfuric acid may react with many double-bond, triple-bond, or aromatic compounds, this reaction can be used to convert many compounds found in pesticide and PCB
extracts, from organic-soluble compounds to aqueous-soluble compounds, resulting in an
extract that is much less contaminated. The H2SO4/silica removes the bulk of the lipids
and other oxidizable components from the hexane extract. It is important to note that
many pesticides will undergo this reaction, so such a cleanup can only be used for analysis of PCBs and some pesticides.
338
Hong and Chu
11. The use of prepacked SPE tubes containing silica packing can increase laboratory efficiency and reduce the amount of solvents used for these processes. They are used for
fractionation of HCH from similar organics after acid-modified silica cleanup and for
retaining coextractants that may interfere with GC analysis of HCH. Slower gravity elution of the samples will minimize premature breakthrough or channeling and will ensure
maximum recoveries in the recovered fraction. It is very important to evaluate each lot of
tubes to ensure minimal background from the device itself and to verify that the packing
is at maximum activity level to maintain the expected retention capacity.
12. Splitless injection is usually used for HCH analysis. However, in environmental samples
that have relatively low concentration of α-HCH enantiomers, large-volume injection has
advantages over splitless injection. The benefit of large-volume injection is the obvious
improvement in sensitivity. A second benefit to large-volume injection is a savings of
time and effort in the preparation of small volume of samples (concentration step) for GC
analysis; this also improves the accuracy of the procedure by eliminating losses associated with the concentration step. The major technical challenge associated with largevolume injection is to remove the solvent without losing the analytes of interest. PTV
injectors can be used for the injection of large sample volumes, either by multiple injections or by solvent venting in the cold split mode. For a multiple-injection method, large
volumes are injected in several smaller fractions (up to eight injections), with the solvent
evaporating at low temperatures and exiting through the open split vent, between one
injection and the next. Once a sufficient quantity of trace analytes is built up, the injector
temperature is rapidly increased to evaporate the solutes onto the column. The solvent
venting process, time, flow, and temperature all need to be optimized to minimize the loss
of the analytes of interest.
13. Because α-HCH is an early-eluting organochlorine compound, the number of potential
coelutions is limited after a good sample cleanup (lipid removal and group separation by
SPE). This allows the application of relatively short GC columns as well as low separation temperatures. Because of the relatively low maximal operation temperatures of chiral
GC columns (Tmax = 200°C and Tmax = 225°C for isothermal and temperature programming, respectively), comparably long hold times at the final temperature are necessary
before the next injection.
14. In most enantiomer analyses, a definitive order of elution can only be established by
injection of enantio-enriched standards. In the case of α-HCH, the elution order of the
enatiomers on various CSPs is well known. Loss of a chiral compound during the sample
cleanup will not influence the ER. The ER is not influenced by sample manipulations
(dilution, injection, detection, or chemical and physical losses). Therefore, an individual
enantio-enriched α-HCH standard is not necessary for the determination of ER or EF values.
15. The enantiomeric composition of chiral chemicals can be expressed as ratios (ERs) or
fractions (EFs). ERs are more commonly used; EFs are more easily compared and used in
mathematical equations (23). The ER is defined as ER = A+/A- [A+ and A- correspond the
peak areas of the (+) and (−) enantiomers] when the optical rotations are known; otherwise, the ER is expressed as ER = A1/A2 (the peak area of the first eluting enantiomer over
the second eluting enantiomer). The corresponding EF is defined as EF = A+/(A+ + A-) or
EF = A1/(A1 + A2). The EF can also be calculated from the ER value by the equation EF =
ER/(ER + 1).
16. The verification of the expected 1:1 ratio of a racemic mixture is mandatory in enantiomer analysis by chromatography. Indeed, a racemic composition represents an ideal
equimolar mixture and is useful for testing the precision of integration facilities, which
should always produce a correct ER of 1.
α-Hexachlorocyclohexane in Food
339
References
1. Kutz, F. W., Wood, P. H., and Bottimore, D. P. (1991) Organochlorine pesticides and
polychlorinated-biphenyls in human adipose-tissue. Rev. Environ. Contam. Toxicol. 120,
1–82.
2. Li, Y.-F., McMillan, A., and Scholtz, M. T. (1996) Global HCH usage with 1° × 1° longitude/latitude resolution. Environ. Sci. Technol. 30, 3525–3533.
3. Simonich, S. L. and Hites, R. A. (1995) Global distribution of persistent organochlorine
compounds. Science 269, 1851–1854.
4. Willett, K. L., Ulrich, E. M., and Hites, R. A. (1998) Differential toxicity and environmental fates of hexachlorocyclohexane isomers. Environ. Sci. Technol. 32, 2197–2207.
5. Hegeman, W. J. M. and Laane, R. W. P. M. (2002) Enantiomeric enrichment of chiral
pesticides in the environment. Rev. Environ. Contam. Toxicol. 173, 85–116.
6. Mössner, S., Spraker, T. R., Becker, P. R., and Ballschmitter, K. (1992) Ratios of enantiomers of α-HCH and determination of α-, β-, and γ-HCH isomers in brain and other tissues of neonatal northern fur seals (Callorhinus ursinus). Chemosphere 24, 1171–1180.
7. Ulrich, E. M., Willett, K. L., Caperell-Grant, A., and Hites, R. A. (2001) Understanding
enantioselective processes: a laboratory rat model for α-hexachlorocyclohexane accumulation. Environ. Sci. Technol. 35, 1604–1609.
8. Müller, M. D., Schlabach, M., and Oehme, M. (1992) Fast and precise determination of αhexachlorocyclohexane enantiomers in environmental samples using chiral high-resolution gas chromatography. Environ. Sci. Technol. 26, 566–569.
9. Jantunen, L. M. and Bidleman, T. F. (1995) Differences in enantioselective degradation of
α-hexachlorocyclohexane in the Bering-Chukchi Seas and the Arctic Ocean.
Organohalogen Compounds 24, 425–428.
10. Pfaffenberger, B., Hühnerfuss, H., Kallenborn, R., Köhler-Günther, A., König, W. A., and
Krüner, G. (1992) Chromatographic-separation of the enantiomers of marine pollutants. 6.
Comparison of the enantioselective degradation of α-hexachlorocyclohexane in marine
biota and water. Chemosphere 25, 719–725.
11. Tanabe, S., Kumaran, P., Iwata, H., Tatsukawa, R., and Miyazaki, N. (1996) Enantiomeric
ratios of α -hexachlorocyclohexane in blubber of small cetaceans. Mar. Pollut. Bull. 32,
27–31.
12. Vetter, W., Klobes, U., Hummert, K., and Luckas, B. (1997) Gas chromatographic separation of chiral organochlorines on modified cyclodextrin phases and results of marine biota
samples. J. High Resol. Chromatogr. 20, 85–93.
13. Vetter, W. and Schurig, V. (1997) Review: enantioselective determination of chiral organochlorine compounds in biota by gas chromatography on modified cyclodextrins. J.
Chromatogr. A 774, 143–175.
14. Kallenborn, R. and Hühnerfuss, H. (ed.). (2001) Chiral Environmental Pollutants. Trace
Analysis and Ecotoxicology. Springer-Verlag, New York.
15. Buser, H.-R. and Müller, M. D. (1994) Isomer- and enantiomer-selective analyses of toxaphene components using chiral high-resolution gas chromatography and detection by
mass spectrometry/mass spectrometry. Environ. Sci. Technol. 28, 119–128.
16. Hoekstra, P. F., O’Hara, T. M., Karlsson, H., Solomon, K. R., and Muir, D. C. G. (2003)
Enantiomer-specific biomagnification of α-hexachlorocyclohexane and selected chiral
chlordane-related compounds within an Arctic marine food web. Environ. Toxicol. Chem.
22, 2482–2491.
17. Falconer, R. L., Bidleman, T. F., and Szeto, S. Y. (1997) Chiral pesticides in soils of the
Fraser Valley, British Columbia. J. Agric. Food Chem. 45, 1946–1951.
340
Hong and Chu
18. Wiberg, K., Letcher, R. J., Sandau, C. D., Norstrom, R. J., Tysklind, M., and Bidleman, T.
F. (2000) The enantioselective bioaccumulation of chiral chlordane and α-HCH contaminants in the polar bear food chain. Environ. Sci. Technol. 34, 2668–2674.
19. Moisey, J., Fisk, A. T., Hobson, K. A., and Norstrom, R. J. (2001) Hexachlorocyclohexane (HCH) isomers and chiral signatures of α-HCH in the Arctic marine food web of the
Northwater polynya. Environ. Sci. Technol. 35, 1920–1927.
20. Meijer, S. N., Halsall, C. J., Harner, T., et al. (2001) Organochlorine pesticide residues in
archived UK soil. Environ. Sci. Technol. 35, 1989–1995.
21. Fisk, A. T., Holst, M., Hobson, K. A., Duffe, J., Moisey, J., and Norstrom, R. J. (2002)
Persistent organochlorine contaminants and enantiomeric signatures of chiral pollutants in
ringed seal (Phoca hispida) collected on the east and west side of the Northwater Polynya,
Canadian Arctic. Arch. Environ. Contam. Toxicol. 42, 118–126.
22. Wong, C. S., Lau, F., Clark, M., Mabury, S. A., and Muir, D. C. G. (2002) Rainbow trout
(Oncorhynchus mykiss) can eliminate chiral organochlorine compounds
enantioselectively. Environ. Sci. Technol. 36, 1257–1262.
23. Harner, T., Wiberg, K., and Norstrom, R. J. (2000) Enantiomer fractions are preferred to
enantiomer ratios for describing chiral signatures in environmental analysis. Environ. Sci.
Technol. 34, 218–220.
Screening of Pesticides by HS-SPME–GC–MS
343
27
Automated Headspace Solid-Phase Microextraction
and Gas Chromatography–Mass Spectrometry for Screening
and Determination of Multiclass Pesticides in Water
Taizou Tsutsumi, Mitsushi Sakamoto, Hiroyuki Kataoka,
Janusz Pawliszyn
Summary
The method for the determination of multiclass pesticides in water samples by
headspace solid-phase microextraction and gas chromatography–mass spectrometry (HSSPME–GC–MS) is described. Of the 174 pesticides, 158 are extracted with a
polyacrylate-coated fiber at 30 to 100°C and are classified into four groups according to
the shape of their extraction temperature profiles. Each group of pesticides is continuously analyzed by HS-SPME–GC–MS using the Combi PAL autosampler. This method
is successfully applied to the analyses of drinking and environmental water samples. The
automated HS-SPME–GC–MS system is an extremely powerful, flexible, and low-cost
approach for multiclass pesticide analyses in various water samples. The recoveries and
reproducibilities are good, and the results are in good agreement with those obtained by
the solid-phase extraction method. Although it has not yet been theoretically useful, the
physical property diagram may be a valuable tool in inductively predicting adaptability
of untested compounds in the HS-SPME system.
Key Words: Automated analysis; Combi PAL; extraction temperature profile;
headspace solid-phase microextraction; mineral water; multiclass pesticides; river water.
1. Introduction
Pesticides are used on a large scale for agricultural purposes. The adverse effects of
pesticides on both human health and the environment are a matter of public concern.
Thus, both the actual state and the transition of pesticide residues in various matrices,
including water, soil, and agricultural products, should be extensively monitored to
determine that they are within specified limits. Therefore, screening, identification,
and determination methods for these pesticides in the environment are necessary.
Although performance enhancement and improvement of sensitivity and specificity of
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
343
344
Tsutsumi et al.
the analytical instrument have been attempted to satisfy this demand, until now most
analytical instruments could not directly handle complex matrices such as environmental samples. Specifically, sample preparation steps such as extraction, concentration, fractionation, and isolation of analytes are very complicated, and over 80% of
analysis time is generally spent on these steps.
Solid-phase extraction (SPE) has been widely adopted for preparing samples in the
analysis of pesticides. SPE offers the following advantages over liquid–liquid procedures: less organic solvent usage, no forming or emulsion problems, and easier operation. Although conventional sample preparation methods have been used to analyze
pesticide residues in various matrices, many of these methods require expensive instrumentation and an expert analyst and are very time costly. Therefore, efficient analytical systems that do not have these drawbacks are required.
Solid-phase microextraction (SPME), developed by Pawliszyn and coworkers (1),
has received an increasing amount of attention as a simple and convenient sample
preparation technique that can be applied to numerous environmental matrices (2–
10). It saves preparation time, solvent purchase, and disposal costs. The SPME consists of two extraction modes. One is the direct immersion mode (DI-SPME) in which
analytes are extracted from the liquid phase onto an SPME fiber, and the other is the
headspace mode (HS-SPME), in which analytes are extracted from the gaseous phase
(headspace) over liquid or solid samples onto the SPME fiber. DI-SPME and HSSPME techniques can be used in combination with any gas chromatography (GC),
GC–mass spectrometry (MS), high-performance liquid chromatography, and liquid
chromatography–MS systems. In general, DI-SPME is more sensitive than HS-SPME
for analytes present in a liquid sample, although HS-SPME gives lower background
than DI-SPME (2). SPME methods with DI and HS mode have been reported for the
determination of various pesticides in water (11–21). Some compounds need to convert to their volatile derivatives prior to SPME extraction (12,14).
Because it was previously thought that HS-SPME could be used to differentiate
volatile compounds from less-volatile compounds (22), the use of HS-SPME extraction for semi- (and less-) volatile compounds has seldom been applied (4). Furthermore, pesticide extraction is not thought to be more efficient when the temperature
increases to above 60°C (4); therefore, SPME extractions are usually conducted at
room temperature. However, the sensitivity to an analyte and the fundamental applicability of a method toward the analyte are two independent parameters. We considered
that it is necessary to recognize anew the applicability of SPME to the fields in which
researchers take little interest before pursuing the sensitivity of the analytical system.
We attempted to evaluate the applicability of HS-SPME determination of semi- and
less-volatile pesticides in water samples and to expand the application range to the
pesticides in actual matrices.
In this chapter, a screening method for multiclass pesticides categorized into subgroups based on the extraction temperature and a quantitative method for the determination of 45 pesticides using automated HS-SPME–GC–MS with a commercial
autosampler (Combi PAL) (23) are described. The 174 pesticides detectable with GC
were selected objectively and impartially based on their physical properties: vapor
pressure and partition coefficient between octanol and water (see Note 1). The extrac-
Screening of Pesticides by HS-SPME–GC–MS
345
Fig. 1. Automated headspace solid-phase microextraction and gas chromatography–mass
spectrometry system using the Combi PAL autosampler.
tion temperature profiles in HS-SPME were evaluated to classify the pesticides. The
relationship between the features of the pesticide’s extraction temperature profile and
its physical properties provides us with a useful guide not only to systematic screening
of pesticides not included in this study, but also to optimization of HS-SPME in actual
matrices. We also developed a new multiple analytical system using the HS-SPME–
GC–MS used in a great number of pesticide residue monitoring and compared it with
the conventional SPE–GC–MS method. Optimum conditions for the automated HSSPME–GC–MS method and typical problems encountered in the development and
application of the method are discussed.
2. Materials
2.1. Equipment
1. GC ion trap MS system (e.g., Trace GC 2000-Polaris, Thermoquest Co., Austin, TX)
equipped with programmable temperature vaporizing (PTV) injector fitted with a glass
insert (1-mm id) (see Note 2).
2. Rtx-5MS fused-silica capillary column, 30 m × 0.25 mm id, 0.25 µm (e.g., Restek Co.,
Bellefonte, PA).
3. Combi PAL autosampler (Fig. 1) fully controlled with Cycle Composer software (e.g.,
CTC Analytics, Basel, Switzerland) (see Note 3).
4. SPME fibers: 85-µm polyacrylate (PA), 100-µm polydimethylsiloxane (PDMS), 65-µm
PDMS–divinylbenzene (PDMS–DVB), 65-µm carbowax–DVB (CW–DVB), and 75-µm
carboxen–PDMS (CAR–PDMS) (e.g., Supelco Co., Bellefonte, PA).
5. Sep-pack PS-2 plus cartridge (e.g., Waters Co., Milford, MA).
6. Crimp-top headspace vial (20 mL) equipped with a blue silicon/polytetrafluoroethylene
(PTFE) septa and an open-center magnetic cap (e.g., La-Pha-Pack, Langerwehe, Germany).
346
Tsutsumi et al.
2.2. Reagents
1. Pesticide standards (>95% pure). The pesticides are listed in Table 1 (see Note 4).
2. Internal standards thiobencarb-d10 and chlornitrofen-d4 (>96% pure).
3. Other materials: All solvents and anhydrous sodium sulfate are pesticide-analysis grade.
Pure water is used after fresh purification with a Milli-Q Gradient 10A system (e.g.,
Millipore, Tokyo, Japan).
2.3. Solutions
1. Standard pesticide solutions: Standard stock solution (each 1 mg/mL) is prepared in acetone. Each pesticide is mixed at the concentration of 0.01–10 µg/mL in acetone. Several
mixed standard solutions as vial packing are also purchased from Kanto Kagaku (Tokyo,
Japan). These standard solutions are stored at 4°C.
2. Working mixed standard solutions: Appropriate amounts of the mixed standard solutions
of step 1 are spiked into the water–sample vial at a concentration of 0.01–10 ng/mL.
These working standard solutions are stored at 4°C.
3. Internal standard solutions: Internal standard stock solutions (each 1 mg/mL) are prepared in acetone and are stored at 4°C.
2.4. Water Samples
Water samples are pure water, commercially available natural mineral waters
(Volvic®, Evian®, and Contrex) and surface water collected from the river Katsuura
located in Tokushima prefecture in Japan. The natural mineral water and the surface
water are tested to ensure that they are free from the selected pesticides and stored at
4°C until use.
3. Methods
Two methods, HS-SPME and SPE, are proposed. HS-SPME is a new automated
technique and is described in detail. SPE is widely adopted for preparing samples in
the analysis of pesticides and is used for comparison with the HS-SPME method.
3.1. Automated HS-SPME–GC–MS System
Automation of the HS-SPME procedures is achieved with a Combi PAL
autosampler. The computer controlled all the movements of the autosampler and the
GC–MS. Run cycles of autosampler and GC-MS are shown in Fig. 2 (see Notes 5 and 6).
3.1.1. Preparation of Samples
1. A 10-mL volume of a water sample and 4 g anhydrous sodium sulfate are placed in a 20mL crimp-top headspace autosampler vial equipped with a PTFE-coated magnetic stir
bar, and the solution is stirred with a magnetic stirrer at 235g.
2. For preparing the spiked water samples over the concentration range of 0.01–10 ng/mL,
the appropriate amounts of the mixed standard solution of pesticides at 0.01–10 µg/mL in
acetone are spiked into each vial (see Note 7).
3. The vials are sealed with both a blue silicon/PTFE septa and an open-center magnetic
cap, and the solutions are stirred again.
4. In the calibration and quantitation studies, the mixed internal standard solution is also
added to each sample.
Screening of Pesticides by HS-SPME–GC–MS
347
3.1.2. Automated HS-SPME Procedure
1. Photographs of the SPME step using the Combi PAL autosampler are presented in Fig. 3.
All movements of the SPME fiber in the processes of adsorption, desorption, and cleaning could be precisely controlled using this autosampler.
2. The SPME fibers are conditioned before use according to the supplier’s instructions with
the fiber cleaning station in the Combi PAL (see Note 8).
3. The sample vials are set on the sample tray in the Combi PAL, which is programmed to
control the SPME extraction and subsequent desorption (see Note 9).
4. A sample vial is transported into the agitator in the Combi PAL, which keeps the vial
oscillating at an optional fixed temperature during extraction.
5. The SPME needle pierces the septum of the sample vial, and the fiber is exposed in the
headspace above the sample (see Notes 10–12).
6. A suitable SPME extraction temperature can be selected from four types of pesticides by
the relationship between the characteristic features in extraction and their physical properties, such as vapor pressure and octanol/water partition coefficient. In the actual procedures for comprehensive monitoring, the same sample is divided into several vials for
multigroup analysis. Each vial is sequentially examined by each group method in turn
(see Notes 13–21).
7. After suitable extraction time (see Note 21), the fiber is withdrawn into the needle; the
needle is removed from the septum and then inserted directly into the GC injection port.
8. The Combi PAL continuously inserts the fiber into the GC injection port in a short, fixed
interval, and then the GC measurement starts simultaneously (Fig. 2).
9. The sample vial is then returned to the sample tray, and the fiber is thoroughly cleaned at
270°C under nitrogen for 10 min in the cleaning station (inert gas purging) in the Combi
PAL, ready for the next extraction (see Note 22).
3.1.3. Gas Chromatography–Mass Spectrometry
1. GC–MS analysis of the pesticides is performed using a GC system with an ion trap mass
spectrometer. It is equipped with a PTV injector fitted with a glass insert (1-mm id). It is
used in the PTV splitless mode with a splitless time of 3 min and with the following
temperature program: hold at 50°C for 0.5 min, 10°C/s to 250°C, hold for 3 min, 5°C/sec
to 260°C, hold for 28 min (see Note 23).
2. The fused-silica capillary column follows a temperature program of 50°C held for 1 min,
25°C/min to 125°C, 10°C/min to 300°C, hold for 7 min. The carrier gas is helium at a
constant flow (1 mL/min).
3. The GC–MS transfer line is held at 260°C and the ion source at 200°C. The full-scan
mode (scan range 50–500 m/z) for all pesticides and the tandem mass spectrometry (MS/
MS) mode for 11 pesticides (bitertanol, cyproconazole, fenvalerate, fludioxonil,
isofenphos-oxon, metribuzin, myclobutanil, paclobutrazol, propiconazole, pyraclofos,
pyridaphenthion) are used for detection and confirmation of the pesticides. One or two
ions are selected from the spectrum of each pesticide to quantify the response. The ion
energy used for electron impact is 70 eV (see Note 23).
4. The calibration curves are prepared as follows: The ratio of the peak area for the target
pesticide to the peak area for the internal standard is plotted on the y-axis, and the initial
concentration of the target pesticide is plotted on the x-axis. The concentrations of the
pesticides in the samples are 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, and 10 ng/mL.
348
Tsutsumi et al.
Table 1
CAS Registry Number, Physical Properties, Type of Extraction–Temperature Profile,
and Optimum Extraction Temperature of the Studied Pesticides
Screening of Pesticides by HS-SPME–GC–MS
Table 1 (Continued)
349
350
Tsutsumi et al.
Table 1 (Continued)
CAS Registry Number, Physical Properties, Type of Extraction–Temperature Profile,
and Optimum Extraction Temperature of the Studied Pesticides
Screening of Pesticides by HS-SPME–GC–MS
351
Table 1 (Continued)
5. The limit of detection (LOD) is calculated as the concentration giving a signal-to-noise
ratio of 3 (S/N = 3). Pure water samples that are spiked with target pesticides at concentration
levels ranging from 0.01 to 10 ng/mL are analyzed to estimate the LOD (see Notes 24–26).
3.1.4. Analysis of Water Samples
Commercially available natural mineral waters (Volvic, Evian, and Contrex) and
river surface water are tested to ensure that they are free from the selected pesticides.
The recoveries for target pesticides spiked to water samples are determined as the ratio
of peak area in each tested sample to that in pure water under the same conditions (see
Notes 27–29).
3.1.5. Identification and Quantification
Detected analytes are quantified via each ion of pesticides (Table 2) in MS/MS mode.
The concentration (nanograms per milliliter) of the pesticides in the samples is given as
follows:
352
Tsutsumi et al.
Fig. 2. Schematic diagram of the automated continuous analysis by headspace solid-phase
microextraction and gas chromatography–mass spectrometry.
C = (y − b)/a
where y is the area count obtained from the sample; a is the slope of the regression line
in the standard calibration curve; and b is the intercept of the regression line in the
standard calibration curve.
3.2. Solid-Phase Extraction
1. A 500-mL volume of water is spiked with 0.5 mL of the mixed standard solution of
pesticides at 0.5 µg/mL in acetone and mixed well.
2. A Sep-pack PS-2 plus cartridge is conditioned by sequentially rinsing with 5 mL each of
dichloromethane, methanol, and pure water.
3. The 500-mL water sample is then pulled through the SPE cartridge at a flow rate of 10
mL/min.
4. The SPE cartridge is dried by introducing air into the cartridge for more than 30 min to
dislodge the bound water.
353
Fig. 3. Photographs of each step of headspace solid-phase microextraction using the Combi PAL. (A) Transfer of vial from sample tray to
agitator; (B) agitation for equilibration (heat block is actually covered); (C) insertion of the fiber into headspace of sample vial during agitation;
(D) fiber cleaning in the fiber-cleaning station after desorption in the GC injection port.
Screening of Pesticides by HS-SPME–GC–MS
353
354
Tsutsumi et al.
Table 2
Quantitation Ion, Limits of Detection (LOD), Linearity, and Precision Data
for 45 Pesticides by HS-SPME
From ref. 23, with permission.
Screening of Pesticides by HS-SPME–GC–MS
355
5. The SPE cartridge is then eluted with 3 mL dichloromethane.
6. The dichloromethane eluate is evaporated under nitrogen until its volume is condensed to
less than 0.5 mL, and 0.5 mL of the solution containing thiobencarb-d10 and chlornitrofend4 at 0.5 µg/mL is added as internal standard.
7. Adjust 1 µL of the solution to 1 mL with dichloromethane, then inject into the GC–MS
(see Note 30).
4. Notes
1. Vapor pressure Pv and octanol/water partition coefficient P are taken from the literature
(24,25). Because the Pv and P vary widely, it is convenient to express them on a logarithmic scale. The log Pv values range from −7.0 to 5.5, and partition coefficient (log P)
values range from −0.6 to 8.2.
2. A quadrupole ion trap mass spectrometer is adopted as a GC–MS detector because of its
accurate identification of a target pesticide in both full-scan and MS/MS modes (26).
3. The Combi PAL is selected as an SPME module, and mounted on a GC–MS system. It
consists of a sample tray with valuable vial penetration depth for headspace or liquid
extraction, heated agitator, fiber cleaning station (optional), and injection unit (Fig. 1).
4. Among the 174 pesticides tested, 158 pesticides were detectable at a concentration of 10
ng/mL in pure water. The other 16 pesticides could not be detected at 10 ng/mL under any
condition used in this study.
5. Because the movements of the GC–MS and the autosampler are independent of each
other, different procedures for two samples [GC procedure for nth sample and SPME
procedure for (n + 1)th sample] could be performed simultaneously. Moreover, GC measurements for samples could be consecutively carried out by synchronizing the end of the
GC–MS procedure for the former sample with the start of the GC injection in the SPME
procedure for the latter sample (Fig. 2).
6. The entire SPME and GC–MS analysis of pesticides is accomplished automatically within
60 min.
7. The total concentration of acetone in each sample vial throughout the study was controlled within 0.05% (v/v).
8. The HS-SPME technique reduces background adsorption and matrix effects and consequently enhances the life expectancy of the SPME fiber because the fiber is not in contact
with the sample (27). The SPME fiber must be carefully handled because the coating is
prone to strip from the needle during insertion and removal.
9. The sample vials can be set up to 32.
10. Five different commercially available SPME fibers (PA, PDMS, PDMS–DVB, CW–
DVB, and CAR–PDMS) were tested for HS-SPME extraction of pesticides from water
samples. Although the optimum fibers differed depending on the pesticide, all 158 pesticides except pencycuron could be sufficiently extracted with the PA fiber. The chromatogram of pencycuron extracted with the PA fiber is not suitable for quantitative treatment
because of the small peak and the spread band.
11. The salt addition in HS-SPME increases the ionic strength of the solution, consequently
decreasing the solubility of analyte, and the affinity of analyte to gaseous phase increases.
The effect of the salt addition on the HS-SPME was tested at the concentration of 0–50%
(w/v) of sodium sulfate with the PA fiber for 30 min at 80°C. The increase in the extraction yield for most pesticides declined when more than 40% (w/v) of sodium sulfate was
356
12.
13.
14.
15.
16.
17.
Tsutsumi et al.
added. In addition, it was observed that the rates of increase for pesticides with log P
values below 4 (log P < 4) are higher than those for pesticides with log P values above 4
(log P > 4). There was no change in the value of pH for each mixture solution, in which
the 40% (w/v) of sodium sulfate is already added, before and after the working standard
mixture was added. Therefore, no pH adjustment for the tested solution was carried out.
To optimize the extraction time and temperature, HS-SPME of pesticides was tested by
triplicate extractions with PA fiber from 10-mL pure water samples spiked with the studied pesticides at 10 ng/mL containing 40% (w/v) sodium sulfate as the extraction time
was increased in 10-min steps from 10 to 60 min and the extraction temperature was
increased in 10° steps from 30 to 100°C. The optimum extraction temperature for each
pesticide (see Table 1) was determined after due consideration of not only the extraction
temperature profile, but also the extraction time profile.
The extraction temperature profiles are classified into four types according to their shapes
(Table 1). Typical examples of types 1–3 profiles are shown in Fig. 4A–C, respectively.
The log Pv and log P values of the pesticides classified into the same type aggregate into
a cluster. The distribution of three types and boundary lines of the applicability are shown
in Fig. 5.
Type 1: A peak shape is a characteristic feature of this type. The profile has one peak in
which the apex lies at 60–80°C. The extraction yield increases by elevating the temperature from 30°C to the apex level at 60–80°C. As the temperature increases to a value
higher than the apex temperature, the extraction yield rapidly decreases. Although we
have not yet confirmed the mechanism behind their profiles experimentally, there seem
to be two possibilities. One is a reduction in the distribution coefficients between the
coating material and analytes at elevated temperature (27), and the other is hydrolysis of
the pesticides (28). The log Pv and log P values of the pesticides in this type range from −
2.0 to 5.5 and from 1.7 to 6.5, respectively. The physical property values of the pesticides
in this type are distributed in circle A (Fig. 5) with one exception, dichlorodiisopropyl
ether (DCIP).
Type 2: A plateau shape is a typical feature of this type. In contrast to type 1, the profile
of this type does not have a well-defined peak. The extraction yield increases with elevating temperature until it reaches a maximum at 60–80°C. The extraction yield is steady or
slightly decreases as temperature increases to higher than the maximum temperature. The
log Pv and log P values of the pesticides in this type range from −3.9 to 1.9 and from 1.6
to 6.9, respectively. The physical property values of the pesticides in this type are distributed in circle B (Fig. 5). Circle B lies on the upper and left side of circle A.
Type 3: A steep slope is a characteristic feature of this type. An outstanding characteristic
of this type is its uniqueness. There is no or a poor extraction yield of each pesticide that
belonged to Type 3 at room temperature. Over the boundary temperature (about 60°C),
the extraction yield of the pesticides continued to increase with temperature until 100°C.
The log Pv and log P values of the pesticides in this type range from −7.1 to 1.3 and from
1.6 to 8.2, respectively. The physical property values of the pesticides in this type are
distributed in circle C (Fig. 5) with a few exceptions, a larger area than both circles A and
B. Circle C is upward and to the left of circles A and B. The discovery of type 3 contributed greatly to the enhancement of applicability from the viewpoint that the physical
properties are spread over a wide range of values.
Type 4: This type has no defining feature. The profiles of three pesticides (dichlofluanid,
folpet, and fthalide) are classified into this type as shown in Table 1. The phenomenon
caused by hydrolysis is observed in folpet as follows: In the extraction time profile at 30–
Screening of Pesticides by HS-SPME–GC–MS
357
Fig. 4. Example extraction profiles given by analyzing pure water samples (10 mL) spiked
at 1 ng/mL of each pesticide. Each point represents an average of triplicate extractions with a
PA fiber. EPN, p-nitrophenyl phenyl phosphonothionate. From ref. 23 with permission. Copyright 2004 Elsevier.
358
Tsutsumi et al.
Fig. 5. Physical property diagram rearranged according to the classification of extraction
temperature profiles of the selected pesticides. logPv, logarithmic value of vapor pressure
(mPa); logP, logarithmic value of octanol–water partition coefficient. From ref. 23 with permission. Copyright 2004 Elsevier.
50°C, the extraction yields of folpet started decreasing at 40–60 min, whereas they continued to increase from 10 to 30 min. There were no pesticides observed in the extract
over the course of the extraction (10–60 min) at temperatures higher than 50°C.
18. Although the regions in the circles overlap each other (Fig. 5), this diagram is useful for
estimating the extraction feature in pesticides that have not been examined.
19. A line of demarcation separating detectable pesticides and nondetectable pesticides can
be drawn in the diagram (Fig. 5). The observation that the demarcation line is curved
upper and leftward suggests that the hydrophobic pesticides are apt to be extracted more
easily than hydrophilic pesticides as the vapor pressure of pesticide becomes lower.
20. The decision of analytical condition for a pesticide in multigroup analysis does not necessarily coincide with the optimization for the pesticide but is more simple and flexible than
the fractionation adjustment in such conventional sample preparations as liquid–liquid
extraction and SPE. When a new pesticide should be added in a monitoring list, it is easy
to select the grouping temperature for the pesticide because the preexamination for ob-
Screening of Pesticides by HS-SPME–GC–MS
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
359
taining the extraction profile of the pesticide can be rapidly carried out by the autosampler
device. Therefore, new pesticides can be easily classified into the suitable group without
altering the conditions established for already-existing pesticides.
It is difficult to carry out the simultaneous determination of 45 pesticides under one set of
conditions because their optimum conditions are different from each other (Table 1).
Therefore, multigroup analysis is adopted for the simultaneous determination of 45 pesticides. The 45 pesticides are divided into three groups and extracted at 60, 80, or 100°C, as
shown in Table 2. The pesticides are extracted with the PA fiber for 40 min in such a way
that each sample could be analyzed within 1 h. The values for the quantitative evaluations
are obtained under the conditions for the multigroup method, not under the optimum
conditions for each pesticide.
One fiber can be used repeatedly at least more than 100 times.
To determine whether the automated HS-SPME–GC–MS system is quantitatively useful
for detecting multiresidue pesticides in water, 45 of the 158 detectable pesticides were
selected. The selected pesticides and the selected ions (m/z) for the determination of each
pesticide with the mass chromatograms under full-scan and MS/MS modes are listed in
Table 2.
The calibration curves are linear, ranging from 0.05 to 5 µg/mL. The correlation coefficient was calculated from the 15 data (triplicates in five points) on the calibration curve
and ranged between 0.979 and 0.999, as shown in Table 2.
The LOD values for each pesticide are given in Table 2. The values of 0.01 ng/mL in
LOD for the 17 pesticides are achieved only under approximate conditions for screening,
not under optimized conditions for each pesticide.
The precision of the method is evaluated by calculating the relative standard deviation
(RSD) in pure water. The RSD values for each pesticide in pure water are obtained by
triplicate analysis of spiking target pesticides into pure water at the concentration of the
lowest standard solution for each calibration curve. The RSD values ranged from 3.6 to
18% (Table 2). The HS-SPME system could provide superior productivity and reproducibility.
To confirm validity of the HS-SPME–GC–MS method, known amounts of pesticides are
spiked at 0.5 ng/mL to water samples (pure water, three different natural mineral waters,
and surface water), and their recoveries are calculated. Of the 45 pesticides tested, 7
(metalaxyl, malathion, fthalide, methyldymron, edifenphos, pyridaphenthion, and
mefenacet) were excluded from subsequent examinations because the LOD values for
these seven pesticides were more than 0.5 ng/mL. The mean recovery values and the RSD
values for the 38 selected pesticides in water samples at the concentration of 0.5 ng/mL
were obtained with five replicate analyses (Table 3).
Typical chromatograms for the spiked pesticides in pure water and in the surface water
are shown in Fig. 6.
The recovery values and the RSD values of the HS-SPME technique are compared with
those values of the SPE technique by analyzing pure water and surface water samples
(five replicates) spiked with the tested pesticides at 0.5 ng/mL. The results are in good
agreement with those obtained by SPE, as shown in Table 3.
The GC–MS conditions are the same as those of the HS-SPME–GC–MS method except
for a splitless time of 1 min.
360
Table 3
Recoveries and Relative Standard Deviations (RSD) for 38 Pesticides in Water Samples
by HS-SPME and SPE
360
Tsutsumi et al.
361
Screening of Pesticides by HS-SPME–GC–MS
Table 3 (Continued)
Recoveries and Relative Standard Deviations (RSD) for 38 Pesticides in Water Samples
by HS-SPME and SPE
361
362
362
Tsutsumi et al.
Fig. 6. HS-SPME–GC–MS mass chromatograms for the studied pesticides in (A) pure water spiked at 0.5 ng/mL of each pesticide and (B)
surface water (Katsuura River) spiked at 0.5 µg/mL of each pesticide. GC–MS conditions: Rtx-5MS column (30 m × 0.25 mm i., 0.25-µm film
thickness); column temperature programmed at 50°C, hold for 1 min, 25°C/min to 125°C, 10°C/min to 300°C, hold for 7 min; PTV splitless
mode injection with a splitless time of 3 min and with the following temperature programmed at 50°C, hold for 0.5 min, 10°C/s to 250°C, hold for
3 min, 5°C/s to 260°C, hold for 28 min; helium carrier gas at a constant flow (1 mL/min); 260°C transfer line temperature; 200°C ion source
temperature; 70-eV ionization voltage. Peaks: 1, dichlorvos (m/z 185); 2, simetryne (m/z 213); 3, thiobencarb (m/z 100); 4, mepronil (m/z 119).
Screening of Pesticides by HS-SPME–GC–MS
363
References
1. Arthur, C. L. and Pawliszyn, J. (1990) Solid-phase microextraction with thermal desorption using fused silica optical fibers. Anal. Chem. 62, 2145–2148.
2. Kataoka, H., Lord, H. L., and Pawliszyn, J. (2000) Applications of solid-phase
microextraction in food analysis. J. Chromatogr. A 880, 35–62.
3. Lord, H. L. and Pawliszyn, J. (2000) Evolution of solid-phase microextraction technology. J. Chromatogr. A 885, 153–193.
4. Beltran, J., Lopez, F. J., and Hernandez, F. (2000) Solid-phase microextraction in pesticide residue analysis. J. Chromatogr. A 885, 389–404.
5. Alpendurada, M. de F. (2000) Solid-phase microextraction: a promising techniques for
sample preparation in environmental analysis. J. Chromatogr. A 889, 3–14.
6. Pawliszyn, J. (2001) Solid-phase microextraction. Adv. Exp. Med. Biol. 488, 73–87.
7. Kataoka, H. (2002) Automated sample preparation using in-tube solid-phase
microextraction and its application—a review. Anal. Bioanal. Chem. 373, 31–45.
8. Buldini, P. L., Ricci, L., and Sharma, J. L. (2002) Recent applications of sample preparation techniques in food analysis. J. Chromatogr. A 975, 47–70.
9. Zambonin, C. G. (2003) Coupling solid-phase microextraction to liquid chromatography.
A review. Anal. Bioanal. Chem. 375, 73–80.
10. Krutz, L. J., Senseman, S. A., and Sciumbato, A. S. (2003) Solid-phase microextraction
for herbicide determination in environmental samples. J. Chromatogr. A 999, 103–121.
11. Lambropoulou, D. A. and Albanis, T. A. (2001) Optimization of headspace solid-phase
microextraction conditions for the determination of organophosphorus insecticides in natural waters. J. Chromatogr. A 922, 243–255.
12. Henriksen, T., Svensmark, B., Lindhardt, B., and Juhler, R. K. (2001) Analysis of acidic
pesticides using in situ derivatization with alkylchloroformate and solid-phase
microextraction (SPME) for GC–MS. Chemosphere 44, 1531–1539.
13. Queiroz, M. E., Silva, S. M., Carvalho, D., and Lancas, F. M. (2001) Comparison between
solid-phase extraction methods for the chromatographic determination of organophosphorus pesticides in water. J. Environ. Sci. Health B 36, 517–527.
14. Gerecke, A. C., Tixier, C., Bartels, T., Schwarzenbach, R. P., and Muller, S. R. (2001)
Determination of phenylurea herbicides in natural waters at concentrations below 1 ng/L
using solid-phase extraction, derivatization, and solid-phase microextraction-gas chromatography-mass spectrometry. J. Chromatogr. A 930, 9–19.
15. Ramesh, A. and Ravi, P. E. (2001) Applications of solid-phase microextraction (SPME) in
the determination of residues of certain herbicides at trace levels in environmental samples.
J. Environ. Monit. 3, 505–508.
16. Boussahel, R., Bouland, S., Moussaoui, K. M., Baudu, M., and Montiel, A. (2002) Determination of chlorinated pesticides in water by SPME/GC. Water Res. 36, 1909–1911.
17. Perez-Trujillo, J. P., Frias, S., Conde, J. E., and Rodriguez-Delgado, M. A. (2002) Comparison of different coatings in solid-phase microextraction for the determination of organochlorine pesticides in ground water. J. Chromatogr A 963, 95–105.
18. Tomkins, B. A. and Ilgner, R. H. (2002) Determination of atrazine and four organophosphorus pesticides in ground water using solid phase microextraction (SPME) followed by
gas chromatography with selected-ion monitoring. J. Chromatogr. A 972, 183–194.
19. Souza, D. A. and Lancas, F. M. (2003) Solventless sample preparation for pesticides analysis in environmental water samples using solid-phase microextraction-high resolution gas
chromatography/mass spectrometry (SPME–HRGC/MS). J. Environ. Sci. Health B 38,
417–428.
364
Tsutsumi et al.
20. Li, H. P., Li, G. C., and Jen, J. F. (2003) Determination of organochlorine pesticides in
water using microwave assisted headspace solid-phase microextraction and gas chromatography. J. Chromatogr. A 1012, 129–137.
21. Gonçalves, C. and Alpendurada, M. F. (2004) Solid-phase microextraction–gas chromatography–(tandem) mass spectrometry as a tool for pesticide residue analysis in water
samples at high sensitivity and selectivity with confirmation capabilities. J. Chromatogr.
A 1026, 239–250.
22. Zhang, Z. and Pawliszyn, J. (1993) Headspace solid phase microextraction. Anal. Chem.
65, 1843–1852.
23. Sakamoto, M. and Tsutsumi, T. (2004) Applicability of headspace solid-phase
microextraction to the determination of multi-class pesticides in waters. J. Chromatogr. A
1028, 63–74.
24. TomLin, C. D. S. (ed.). (2002) The e-Pesticide Manual, A World Compendium, 12th ed.
British Crop Protection Council, Bracknell, U.K.
25. Research Center for Environmental Risk (provider). Webkis-Plus Chemicals Database.
Available at: http://w-chemdb.nies.go.jp/index.html (2003). National Institute for Environmental Studies, Ibaraki, Japan.
26. Reyzer, M. L. and Brodbelt, J. S. (2001) Analysis of fire ant pesticides in water by solidphase microextraction and gas chromatography/mass spectrometry or high-performance
liquid chromatography/mass spectrometry. Anal. Chim. Acta 436, 11–20.
27. Doong, R. A. and Liao, P. L. (2001) Determination of organochlorine pesticides and their
metabolites in soil samples using headspace solid-phase microextraction. J. Chromatogr.
A 918, 177–188.
28. Zini, C. A., Lord, H., Christensen, E., de Assis, T. F., Caramão, E. B., and Pawliszyn, J.
(2002) Automation of solid-phase microextraction–gas chromatography–mass spectrometry extraction of eucalyptus volatiles. J. Chromatogr. Sci. 40, 140–146.
In-Tube SPME–LC–MS of Herbicides in Water
365
28
Analysis of Herbicides in Water by On-Line In-Tube
Solid-Phase Microextraction Coupled With Liquid
Chromatography–Mass Spectrometry
Hiroyuki Kataoka, Kurie Mitani, and Masahiko Takino
Summary
We have developed a method using in-tube solid-phase microextraction coupled with
liquid chromatography–mass spectrometry (SPME–LC–MS) for the assay of herbicides
in water samples. Chlorinated phenoxy acid herbicides have been automatically extracted
into a DB-WAX capillary by repeated draw/eject cycles of sample solution and desorbed
with acetonitrile. Triazine herbicides have also been extracted easily by this in-tube
SPME method. Compared with direct sample injection into LC–MS, the in-tube SPME
technique resulted in a greater than 25-fold concentration. The automated in-tube SPME–
LC–MS system can continuously extract herbicides from aqueous samples, followed by
LC–MS. It provides a simple, rapid, selective, sensitive, low-cost method for herbicide
analyses and can be directly applied to various water samples without any pretreatment.
Although the in-tube SPME technique has not yet been extensively applied, its application to various fields is expected because the analytical processes, from sample preparation to chromatography and data analysis, can be automated.
Key Words: Automated analysis; chlorinated phenoxy acid herbicides; in-tube solidphase microextraction; liquid chromatography–mass spectrometry; river water; triazine
herbicides.
1. Introduction
Throughout the world, pesticides and herbicides are used in agriculture on an increasingly large scale, with pollution from these agents spread throughout ecosystems
by leaching and runoff from soil into groundwater and surface water. When released
into the environment, these compounds can also disrupt normal endocrine function in
a variety of aquatic and terrestrial organisms, making appropriate control of these compounds and prevention of related health hazards important (1–3). Thus, both the actual
state and the transition of residues of pesticides and herbicides in various matrices,
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
365
366
Kataoka, Mitani, and Takino
including water, soil, and agricultural products, have received increasing attention in
the last few decades. These environmental samples have been analyzed by various
techniques, including gas chromatography (GC), high-performance liquid chromatography (HPLC), and capillary electrophoresis using various detection systems, to obtain
quantitative and qualitative information on the presence of these residues (4–7). Most
of these techniques, however, require extensive and time-consuming sample preparation methods, such as extraction, concentration, fractionation, and isolation, prior to
analysis, leading to the need for a major simplification in sample preparation methods,
including miniaturization in scale (8–13).
Solid-phase microextraction (SPME) (14) is a simple and convenient sample preparation technique that uses a fused-silica fiber coated on the outside with an appropriate
stationary phase. The analyte in a sample is directly extracted onto the fiber coating.
SPME has been used routinely in combination with GC and GC–mass spectrometry
(GC–MS) and successfully applied to a wide variety of compounds in gaseous, liquid,
and solid samples, especially for the extraction of volatile and semivolatile organic
compounds from environmental samples (12,13,15–20). SPME has also been directly
coupled with HPLC and LC–MS to analyze weakly volatile or thermally labile compounds not amenable to GC or GC–MS. In addition, a new SPME–HPLC system,
known as in-tube SPME, which uses an open-tubular fused-silica capillary instead of
the SPME fiber, has been developed (16,21,22). In-tube SPME is suitable for automation, and extraction, desorption, and injection can be performed continuously using a
standard autosampler. Automated sample-handling procedures not only shorten total
analysis time, but also are more accurate and precise than manual techniques. With the
in-tube SPME technique, organic compounds in aqueous samples are directly extracted
from the sample into the internally coated stationary phase of a capillary and then
desorbed by introducing a stream of mobile phase or static desorption solvent when
the analytes are more strongly adsorbed to the capillary coating. Desorbed compounds
are finally injected into the column for analysis. The in-tube SPME method has been
used in the analysis of pesticides and herbicides from environmental matrices (21–26).
In this chapter, we describe a method for the analysis of herbicides in environmental waters using automated on-line in-tube SPME coupled with LC–MS. LC–MS with
electrospray ionization (LC–MS/ESI) was used to analyze six chlorinated phenoxy
acid herbicides, whereas LC–tandem mass spectrometry (LC–MS/MS) was used to
analyze five triazine herbicides. Optimum conditions for the in-tube SPME method
and typical problems encountered in the development and application of this method
are discussed.
2. Materials
2.1. Equipment
1. Liquid chromatograph (e.g., Agilent 1100 series, Agilent Technologies, Waldborn, Germany), consisting of a vacuum solvent degassing unit, a binary high-pressure gradient
pump, an autosampler, a column thermostat, and a diode array detector connected on line
to the MS system described here.
2. MS system single-quadrupole instrument for the analysis of chlorinated phenoxy acid
herbicides (e.g., an Agilent 1100 series mass selective detector [MSD], equipped with
In-Tube SPME–LC–MS of Herbicides in Water
3.
4.
5.
6.
367
orthogonal spray/ESI (e.g., Agilent Technologies, Palo Alto, CA). LC–MS data are analyzed using LC/MSD ChemStation software (e.g., Agilent, Palo Alto, CA).
MS system triple-quadrupole mass spectrometer for the analysis of triazine herbicides
(e.g., API 4000, Applied Biosystems, Foster City, CA) and equipped with a turbo ion
spray interface. LC–MS/MS data are analyzed using software (e.g., Analyst Software
1.3.1, Applied Biosystems).
LC columns: An inertsil octadecylsilane 3 (ODS3) LC column 150 × 2.1 mm id, 5-µm LC
column (e.g., GL Science, Tokyo, Japan) for the analysis of chlorinated phenoxy acid
herbicides and a TSK gel Super-Octyl 100 × 2.0 mm id, 2-µm LC column (e.g., TOSOH,
Tokyo, Japan) for the analysis of triazine herbicides.
GC capillaries (60 cm long) for in-tube SPME: DB-1 with 0.25-mm id, 1.0-µm film thickness (e.g., J&W Scientific, Folsom, CA); DB-5 with 0.25-mm id, 1.0-µm film thickness
(e.g., J&W Scientific); DB-17 with 0.25-mm id, 1.0-µm film thickness (e.g., J&W Scientific); DB-50 with 0.25-mm id, 1.0-µm film thickness (e.g., J&W Scientific); DB-WAX,
0.25-mm id, 1.0-µm film thickness (e.g., J&W Scientific); Carbowax, 0.25-mm id, 1.0µm film thickness (e.g., Supelco Co., Bellefonte, PA); Omegawax 250 with 0.25-mm id,
1.0-µm film thickness (e.g., Supelco Co.); and Supel Q-PLOT, 0.32-mm id, 12-µm film
thickness (e.g., Supelco Co.) (see Note 1).
Screw-cap autosampler 2-mL vials equipped with silicon/polytetrafluoroethylene septa
(e.g., Agilent Technologies, Palo Alto, CA).
2.2. Reagents and Solutions
1. Chlorinated phenoxy acid herbicides (>99% pure): 4-chloro-2-methylphenoxy acetic acid
(MCPA); 2,4-dichlorophenoxy acetic acid (2,4-D); 2-(2,4-dichlorophenoxy) propionic
acid (dichlorprop); 2,4,5-trichlorophenoxy acetic acid (2,4,5-T); 3-(2,4-dichlorophenoxy)
butyric acid (2,4-DB); and 2-(2,4,5-trichlorophenoxy) propionic acid (2,4,5-TP) (e.g.,
Hayashi Pure Chemicals, Osaka, Japan). The chemical structures of these herbicides are
shown in Fig. 1A.
2. Triazine herbicides (>99% pure): atrazine, simazine, ametryne, propazine, and
prometryne (e.g., GL Science). These chemical structures are shown in Fig. 1B.
3. Standard herbicide solutions: Standard stock solution (each 1 mg/mL) is prepared in
methanol, stored in the dark at 4°C, and diluted to the desired concentration with pure
water prior to use.
4. Ammonium acetate, formic acid, dibutylamine acetate (DBA), and acetonitrile.
5. Other materials: solvents and pure water for mobile phase are HPLC grade. All other
chemicals are of analytical reagent grade. Water is purified with a Milli-Q system
(Millipore, Tokyo, Japan).
2.3. Water Samples
Water samples from a river, a lake, the pond of a golf course, and a paddy field
were collected in glass bottles, filtered through 0.2-µm nylon syringe filters 13 mm in
diameter (TOSOH, Tokyo, Japan), and stored at 4°C until tested.
3. Methods
3.1. Preparation of Samples
1. Water samples are adjusted to the appropriate pH to increase the extraction efficiency of
the analyte to stationary phase in SPME (see Note 2).
368
Kataoka, Mitani, and Takino
Fig. 1. Chemical structures of the chlorinated phenoxy acid and triazine herbicides used in
this study.
In-Tube SPME–LC–MS of Herbicides in Water
369
2. For the analysis of chlorinated phenoxy acid herbicides, 0.9 mL of each water sample is
transferred to a 2-mL screw-cap autosampler vial to which 0.1 mL of 20 mg/mL formic
acid is added. The vial is vortexed and set onto the sample tray in the autosampler (see
Note 3).
3. For the analysis of triazine herbicides, 1.0 mL of each water sample is transferred to a 2mL screw-cap autosampler vial, and the vial is set on the sample tray in the autosampler.
3.2. Automated In-Tube SPME–LC–MS System
The in-tube SPME procedures are automated with an Agilent 1100 series
autosampler. The computer controls all movements of the autosampler and LC–MS. A
schematic diagram of the in-tube SPME–LC–MS system is shown in Fig. 2.
3.2.1. Automated In-Tube SPME Procedure
1. The GC capillary used as an in-tube SPME device is cut to the appropriate length with a
ceramics cutter (see Notes 4–7).
2. The capillary is placed between the injection loop and the injection needle of the
autosampler. A photograph of the connection of the GC capillary and the autosampler is
presented in Fig. 3 (see Note 8).
3. Vials (2 mL) are each filled with 1 mL sample to be extracted and set onto the autosampler,
which is programmed to control the SPME extraction and desorption technique. In addition, 2-mL autosampler vials with septa and 1.5 mL each of methanol and water are set
onto the autosampler (see Note 9).
4. The capillary column is washed and conditioned by two repeated draw/eject cycles (40
µL each) of methanol and water, and a 50-µL air plug is drawn prior to the extraction step
(see Note 10).
5. The extraction of herbicides onto the capillary coating is performed by 20–25 repeated
draw/eject cycles of 30–40 µL of sample at a flow rate of 100–200 µL/min with the sixport valve in the load position (Fig. 2A) (see Notes 11–13).
6. After washing the tip of the injection needle by one draw/eject cycle of 2 µL methanol,
the extracted compounds are desorbed from the capillary coating with acetonitrile or
mobile phase flow (see Notes 14–16).
7. The compounds are transported to the LC column by switching the six-port valve to the
inject position (Fig. 2B) and detected by the diode array detector and MS system. During
LC–MS analysis, the GC capillary is washed and conditioned with mobile phase for the
next extraction (see Notes 17 and 18).
3.2.2. LC–MS for Analysis of Chlorinated Phenoxy Acid Herbicides
1. LC separation of chlorinated phenoxy acid herbicides is performed on a 150 × 2.1 mm
column packed with 5 µm Inertsil ODS3 using linear gradient elution for 15 min with a
mobile phase of acetonitrile–water containing 5 µmol/mL DBA (from 30 + 70 to 85 + 15
v/v). The flow rate is 0.2 mL/min (see Note 19).
2. All MS optimization steps are carried out in the ESI negative ion mode using the analytical column. Nitrogen as nebulizing and drying gas (350°C) is generated from compressed
air using a nitrogen generator. The nebulizing gas pressure is set at 60 psi, and the drying
gas is held at 12 L/min. The drying gas temperature is kept at 350°C, and the fragmentor
voltage for in-source fragmentation is set at 100 V. The skimmers 1, 2, and entrance lens
voltages in the ion source of the MSD are automatically optimized using a calibration
standard and set at 23, 47, and 57 V, respectively. Mass spectra are acquired over the scan
370
370
Kataoka, Mitani, and Takino
Fig. 2. Schematic diagram of the automated in-tube solid-phase microextraction–liquid chromatography–mass spectrometry system: (A)
extraction step; (B) desorption step. SS, stainless steel.
In-Tube SPME–LC–MS of Herbicides in Water
371
Fig. 3. Photograph of the connection between a capillary and the Agilent 1100 autosampler.
3.
4.
5.
6.
range m/z 100–500 unified atomic mass units (u) using a step size of 0.1 u and a scan
speed of 0.5 scan/s (see Notes 20 and 21).
Quantitative analysis is carried out using the selected ion monitoring (SIM) mode of base
ion peaks at m/z 199 (MCPA), 219 (2,4-D), 233 (dichlorprop), 255 (2,4,5-T), 161 (2,4DB) and 267 (2,4,5-TP), with a dwell time of 250–500 ms. To verify the presence of
target analytes in river water, the halogen isotopic ion of all target analytes is monitored
(see Note 22).
The calibration curves are prepared in the range 0.05–50 ng/mL as follows: The ratio of
the peak area for the target herbicide to the peak area count is plotted on the y-axis, and
the initial concentration of the target herbicide is plotted on the x-axis. The concentrations of the chlorinated phenoxy acid herbicides in the samples are 0.05, 0.1, 0.2, 0.5, 1.0,
2.0, 5.0, 10, 20, and 50 ng/mL.
The limit of detection (LOD) is calculated as the concentration giving a signal-to-noise
ratio of three (S/N = 3), and the limit of quantification (LOQ) is defined as 10 times the
standard deviation with a spiked real sample, such as river water. Pure water and river
water samples spiked with target herbicides at concentrations of 0.05 ng/mL and higher
are analyzed to estimate the LOD and LOQ (see Note 23).
The concentration (nanograms per milliliter) of the pesticides in the samples is given as
follows:
C = (y − b)/a
where y is the area count obtained from the sample, a is the slope of the regression line in
the standard calibration curve, and b is the intercept of the regression line in the standard
calibration curve.
372
Kataoka, Mitani, and Takino
3.2.3. LC–MS/MS for Triazine Herbicide Analysis
1. LC separation for triazine herbicides is performed on a 100 × 2.0 mm column packed with
2 µm TSK gel Super-Octyl. The HPLC column temperature is 40°C, and the mobile phase
and flow rate are acetonitrile/2 mM ammonium acetate (50 + 50 v/v) and 0.2 mL/min,
respectively (see Note 24).
2. The turbo ion spray interface is operated in the positive ion mode at 5500 V and 500°C.
Nitrogen as a nebulizing and drying gas is generated from compressed air using a Kaken
N2 generator (System Instruments Co. Ltd., Tokyo, Japan). The ion sources gas 1 (GS1)
and 2 (GS2) are set at 60 and 70 L/min, respectively. The curtain gas flow is set at 20 L/
min, and the collision gas is set at 4.0 L/min (see Note 25).
3. Quantification is performed by multiple reaction monitoring (MRM) of the protonated
precursor ion and the related product ion for triazine herbicides. Quadrupoles Q1 and Q3
are set on unit resolution. MRM in the positive ionization mode is performed using a
dwell time of 150 ms per transition to detect ion pairs at m/z 228.04/186.05 (ametryne;
25-eV collision energy), m/z 215.90/173.95 (atrazine; 25-eV collision energy), m/z
201.93/131.95 (simazine; 27-eV collision energy), m/z 229.93/145.95 (propazine; 33-eV
collision energy), and m/z 242.02/158.05 (prometryne; 33-eV collision energy). The analytical data are processed by Analyst software (version 1.3.1) (see Note 26).
4. The calibration curves are prepared at concentrations ranging from 0.05 to 10 ng/mL by
plotting the ratio of the peak area for the target herbicide to the peak height or peak area
count on the y-axis and the initial concentration of the target herbicide on the x-axis. The
concentrations of the triazine herbicides in the samples are: 0.05, 0.1, 0.2, 0.5, 1.0, 2.0,
5.0, and 10 ng/mL.
5. The LOD is calculated as the concentration giving a signal-to-noise ratio of three (S/N =
3). Pure water and river water samples spiked with target herbicides at concentrations of
0.05 ng/mL and higher are analyzed to estimate the LOD (see Note 27).
6. The concentration (nanograms per milliliter) of the pesticides in the samples is given as
follows:
C = (y − b)/a
where y is the area count obtained from the sample, a is the slope of the regression line in
the standard calibration curve, and b is the intercept of the regression line in the standard
calibration curve.
3.3. Analysis of Water Samples
Various environmental water samples are tested. The recoveries of target pesticides
spiked into water samples are determined as the ratio of peak area in each tested sample
to that in pure water under the same conditions (see Note 28).
4. Notes
1. For in-tube SPME, several commercially available capillary columns are usually used.
Each column has different selectivity in its type of stationary phase, internal diameter,
length, and film thickness, as well as during GC analysis. For example, in a low-polarity
column with methyl silicon liquid phase, the hydrophobic compounds are selectively retained (extracted) in comparison with hydrophilic compounds, whereas in a high-polarity
column with polyethylene glycol liquid phase, hydrophilic compounds are selectively
extracted in comparison with the hydrophobic compounds.
In-Tube SPME–LC–MS of Herbicides in Water
373
2. The extractions of acidic and basic compounds are effective under acidic and alkaline
conditions of the sample solution, respectively. The stability of each compound in the
sample solution, however, must be verified beforehand. Chlorinated phenoxy acid and
triazine herbicides are extracted at acidic pH and neutral pH (in water), respectively.
Although salting out increases the extraction efficiency for fiber SPME, it causes blockage of the column by salt deposits with in-tube SPME. In addition, hydrophilic solvents
such as methanol decrease the extraction efficiency by increasing the solubility of the
compound in the sample. The extraction efficiency, however, is almost uninfluenced by
methanol concentrations of 5% or less. The amount of compound extracted by the stationary phase depends on the concentration of the compound in the sample, and over 0.5
mL is necessary for the injection needle soak using a 2-mL autosampler vial.
3. To increase the extraction efficiency, 0.2% formic acid (pH 2.0) is added as a sample
matrix modifier.
4. Because the capillary column is generally stable for the mobile phase usually used in
HPLC, one capillary can be used repeatedly more than 500 times. To maintain the GC
capillary after 50 samples, it should be rinsed with 100 µL acetonitrile and removed from
the instrument, followed by purging of the remaining solvent with dry nitrogen gas. Although the capillary column with chemically bonded or cross-linked liquid phase is very
stable to water and organic solvents, strong inorganic acids or alkali can easily cause
deterioration. It is therefore necessary to monitor the durability of the coating to exposure
to mobile phases and any desorption solvents required by the loss of response of known
analytes. Thus, it is necessary to monitor the loss of response of known analytes. For the
storage of the capillary, each end should be plugged using a stainless steel union to avoid
oxidation of the stationary phase by air.
5. The internal diameter, length, film thickness, and so on of the column are related to sample
load and the amount of compounds extracted. If these increase, the load and amount extracted will increase, and the extension of sample bandwidth will cause peak broadening
and tailing. In addition, if the film thickness of the stationary phase is large, large amounts
of compound can be extracted, but it may not be possible to desorb the compound quantitatively from the capillary column. In our experience, a 50- to 60-cm length of capillary
column or a narrow-bore column in which the film thickness is comparatively small has
been most suitable for maximizing the extracted amount, for minimizing peak tailing, and
for preventing carryover with in-tube SPME.
6. We compared the extraction efficiencies of three capillaries (DB-WAX, DB-50, and DB1) for chlorinated phenoxy acid herbicides from aqueous solution. As shown in Fig. 4, the
relatively polar DB-WAX gives the best extraction efficiency compared with the lesspolar DB-5 and DB-1 for all herbicides. The effect of film thickness on extraction is very
important in SPME. When we evaluated three capillaries of different thickness (0.25, 0.5,
and 1.0 µm), we found that the maximum extraction efficiency for each herbicide was
obtained using the thickest (1.0 µm).
7. For in-tube SPME of triazine herbicides, a porous polymer-type capillary column, SupelQ PLOT, gives superior extraction efficiency compared with the liquid phase-type capillary columns, Omegawax 250, DB-17, and DB-1 (Fig. 5).
8. In-tube SPME is carried out using the Agilent 1100 series LC system without modification of the autosampler itself. Capillary connections are facilitated using a 2.5-cm sleeve
of 1/16-in. polyetheretherketone (PEEK) tubing at each end of the capillary. A PEEK
tubing internal diameter of 330 µm is suitable for the capillary used. Normal 1/16-in.
stainless steel nuts, ferrules, and connectors are then used to complete the connections.
374
Kataoka, Mitani, and Takino
Fig. 4. Evaluation of three capillary columns for in-tube SPME of chlorinated phenoxy acid
herbicides. In-tube SPME conditions included 100 ng/mL of each herbicide, a sample pH of
5.0, 15 draw/eject cycles, a draw/eject volume of 25 µL, a draw/eject rate of 0.2 mL/min, and
mobile phase desorption (dynamic elution). From ref. 26 with permission.
The injection loop is retained in the system to avoid fouling of the metering pump. The
autosampler software is programmed to control the in-tube SPME extraction, desorption,
and injection.
9. Up to 100 sample vials can be set up.
10. Air plugging before the extraction step is carried out to prevent not only sample mixing
but also desorption of the analyte from the capillary coating by the mobile phase during
the ejection step.
11. The draw/eject volume and the number of sample solutions are related to the extracted
amount and are dependent on the capacity of the column. Complete equilibrium extraction is generally not obtained for any of the analytes, however, because the analytes are
partially desorbed into the mobile phase during each ejection step. Although the amount
extracted increases independent of the draw/eject volume, the bandwidth extends, and the
peak becomes broad. For columns 60 cm long and 0.25 mm in internal diameter, the
column capacity is 29.4 µL, and the capacity from the injection needle (10 µL) to the tip
of the column is 39.4 µL. In our experiments, the optimum draw/eject volume is 30–40
µL for tested drugs, and the extraction efficiency did not increase even at high volumes.
Although an increase in the number of draw/eject cycles can enhance extraction efficiency, peak broadening is often observed. In addition, the draw/eject speed corresponds
to the agitation speed of fiber SPME, and the extraction efficiency increases with this
speed. We find, however, that the optimal flow rate of draw/eject cycles is 50–100 µL/
min. Below this level, extraction requires an inconveniently long time, and above this
level, bubbles form inside the capillary and the extraction efficiency is reduced. Ideally,
In-Tube SPME–LC–MS of Herbicides in Water
375
Fig. 5. Evaluation of five capillary columns for in-tube SPME of triazine herbicides. In-tube
SPME conditions included 100 ng/mL of each herbicide, 20 draw/eject cycles, a draw/eject volume of 40 µL, a draw/eject rate of 0.1 mL/min, and mobile phase desorption (dynamic elution).
the compound has reached distribution equilibrium, and the extraction amount is maximized. To reduce analysis time, it is possible to stop the extraction prior to equilibrium,
but only if sufficient sensitivity is obtained. The extraction time depends on the volume,
speed, and cycle of the draw/eject procedure, and these conditions must be fixed to obtain
quantitative reproducibility.
12. For chlorinated phenoxy acid herbicides, the optimum extraction conditions are 25 draw/
eject cycles of 30 µL sample in 0.2% formic acid (pH 2.0) at a flow rate of 0.2 mL/min
using a DB-WAX capillary (Fig. 6). Extraction equilibrium is not reached for all herbicides after 30 draw/eject cycles, and peak broadening for MPCA, 2,4-D, and dichlorprop
is observed at 30 cycles. This peak broadening is likely because of broadening of the
bandwidth of the analytes extracted into the capillary.
13. For triazine herbicides, the optimum in-tube SPME conditions are 20 draw/eject cycles of
40 µL of sample at a draw/eject rate of 100 µL/min using a Supel-Q PLOT capillary column.
14. There are two methods for desorption of the compound adsorbed to the capillary column:
the dynamic method, which desorbs into the flow of the mobile phase, and the static
method, which desorbs into the solvent aspirated from the outside. Static desorption is
preferred when the analytes are more strongly adsorbed to the capillary coating. In either
case, it is necessary to carry out quick and perfect desorption with a minimum volume of
solvent. For a capillary column 60 cm long and 0.25 mm in internal diameter, desorption
is usually carried out by aspirating 40 µL. For the static method, it is also necessary to
consider the compound’s solubility and miscibility with the mobile phase. For the
dynamic method, it is possible to desorb to the mobile phase flow directly after switching
the six-port valve. Although carryover may be observed after the analysis of highly con-
376
Kataoka, Mitani, and Takino
Fig. 6. Extraction time profiles of chlorinated phenoxy acid herbicides with the DB-WAX
capillary column. Sample modifier is 0.2% formic acid. Other conditions are identical to those
in Fig. 4. From ref. 26 with permission.
15.
16.
17.
18.
19.
centrated samples, it is possible to wash the injection needle and the capillary column by
rinsing with methanol and the mobile phase several times prior to the next analysis via the
draw/eject mode. Therefore, carryover with in-tube SPME is much lower, or eliminated,
in comparison with fiber SPME. It is therefore possible that these conditioning, extraction, and desorption operations are automatically carried out by the overall injection program.
The effect of the desorption solvent on the desorption of chlorinated phenoxy acid herbicides from the capillary is examined using acetonitrile, methanol, and the mobile phase. The
maximum intensities of all analytes are obtained using 10 µL acetonitrile by static desorption. Above 10 µL, peak broadening is observed, although the intensities do not increase.
The extracted triazine herbicides are easily desorbed from the capillary by dynamic desorption using a mobile phase flow, and no carryover is observed because the capillary
column is washed and conditioned by draw/eject cycles of methanol and mobile phase
prior to extraction.
The extraction yields estimated from the amounts of analytes extracted in the stationary
phase by in-tube SPME under optimal conditions ranged from 23.9 to 30.7% for chlorinated phenoxy acid herbicides and 25.7 to 35.7% for triazine herbicides.
The entire automatic in-tube SPME extraction and desorption of chlorinated phenoxy
acid herbicides took 10 min. The in-tube SPME–LC–MS method took 30–40 min, and
automatic analysis of about 40 samples per day is possible during overnight operation.
The postcolumn addition of neutralization buffer is required to form ions in solution and
to facilitate the charging of droplets. An equimolar amount of triethylamine is therefore
added to the formic acid mobile phase at a flow rate of 0.1 mL/min by the tee union
installed between the analytical column and the ion source. The best separation for all
herbicides is obtained with 10 µmol/mL ammonium acetate, 0.1% formic acid, and 5
µmol/mL DBA as the mobile phase modifiers. However, the response factor is at least
In-Tube SPME–LC–MS of Herbicides in Water
20.
21.
22.
23.
24.
25.
377
twice as sensitive for all herbicides when 0.1% triethylamine rather than 0.1% formic
acid is used as the postcolumn additive.
Although the mobile phase containing DBA as a volatile ion-pairing reagent is directly
compatible with MS/ESI, the use of the ion-pairing reagent will cause analyte suppression and a high chemical background because of the formation of a complex with target
analytes (27) if the MS/ESI condition is not optimized. The intensity of the analyte does
not show a large variation when the drying gas flow rate is varied from 4 to 13 L/min. For
the nebulizer gas pressure, when the volatile ion-pairing reagent is used, a higher value
ensures the best sensitivity for the analytes because it can break the neutral ion pairs of
the analytes (28). These parameters are maintained at 12 L/min and 60 psi.
Fragmentor voltage (capillary exit voltage) is applied to the exit of the capillary and affects the transmission and fragmentation of sample ions. At higher fragmentor voltage,
more fragmentation and better ion transmission will occur, and maximum structural information and sensitivity will be obtained. The intensities of the [M–H]– and [M–
RCOOH]- ions for all herbicides are shown as a function of the fragmentor voltage. For
all herbicides except 2,4-DB, which exhibited [M–(CH2)3COOH]- as the base peak, [M–
H]- ions are observed as the base peak at less than 60 V and presented maximum sensitivities. At higher fragmentor voltage, the intensities of [M–H]– ions decreased, and the
intensities of [M–RCOOH]- ions increased. Other ions observed in the mass spectra of all
herbicides are isotopic ions, which derived from the chlorine element and are of maximum abundance for 2,3,5-T and 2,4,5-TP. The fragmentor voltage for all herbicides is set
at 60 V, and Table 1 shows the typical mass spectra of the six chlorinated phenoxy acid
herbicides at 60 V.
The [M–H]- ions are selected for all chlorinated phenoxy acid herbicides, except that [M–
(CH2)3COOH]- is selected for 2,4-DB. Typical total ion and SIM chromatograms of a
standard mixture of six herbicides (each 1 µg/mL) are shown in Fig. 7.
As shown in Table 1, the linearity in the range 0.05–50 ng/mL is very good for all herbicides with correlation coefficients r2 higher than 0.999. The LOD for each herbicide is in
the range 0.005–0.03 ng/mL, whereas the LOQ of each herbicide is in the range 0.02–
0.06 ng/mL. The intraday and interday precisions for the analysis of river water samples
spiked with 0.1 ng/mL are 2.5–4.1% and 6.2–9.1%, respectively. The quantitative results
for all herbicides spiked into river water, at 0.1 ng/mL and using external standards, are
shown in Table 1. The accuracy of these quantitative results is 10–20%, and no significant interference peaks are observed.
Triazine herbicides are analyzed within 10 min on a TSK gel Super-Octyl column. Although ametryne and propazine are partially coeluted (Fig. 8), the tandem mass spectrometer allows the selective detection of substances with varying masses or fragments
without chromatographic separation.
A solution of 10 ng/mL in 50% methanol containing 1% acetic acid infused at a flow rate
of 5 µL/min produced a signal of appropriate abundance in the positive ion mode for the
protonated precursor ion [M+H]+ using the turbo ion spray. Parameters, including nebulizer gas stream, curtain gas, and ion spray voltage, are optimized by flow injection analysis with a mobile phase flow of 0.2 mL/min. Tuning is processed using an automatic
tuning tool of the Analyst software to determine the declustering and focusing potentials,
the fragmentation pattern, the collision energy, and the collision cell exit potential. The
most abundant fragments are sufficiently separated by Q3 in unit resolution, so that could
be used for quantification. The main fragments are formed by the secession of moieties of
masses of m/z 41.99 (possible sum formulas C3H6).
378
Table 1
Sensitivity, Linearity and Precision of Chlorinated Phenoxy Acid Herbicides
Sensitivity (ng/mL)
Herbicides
378
MCPA
2,4-D
Dichlorprop
2,4,5-T
2,4-DB
2,4,5-TP
r2
LODa
LOQb
Quantitativec
results (ng/mL)
0.9998
0.9996
0.9996
0.9998
0.9994
0.9992
0.01
0.005
0.01
0.02
0.03
0.02
0.04
0.02
0.04
0.02
0.06
0.04
0.12
0.09
0.11
0.12
0.11
0.08
Precision (RSD, %)
Repeatabilityd
Reproducibilitye
3.5
2.5
3.3
2.6
4.1
3.7
Kataoka, Mitani, and Takino
Source: From ref. 26 with permission.
of detection (LOD) was defined as S/N = 3 for the river water spiked with 0.05 ng/mL.
bLimit of quantification (LOQ) was defined as 10 standard deviations for five replicates of the river sample spiked with 0.1 ng/mL.
cCalculated for river water spiked at 0.1 ng/mL.
dRepeatability was calculated by analyzing five water samples spiked with 0.1 ng/mL within 1 d.
eReproducibility was calculated by analyzing three river water samples spiked with 0.1 ng/mL per day for 3 d.
aLimit
8.3
9.1
7.9
8.7
7.3
6.2
In-Tube SPME–LC–MS of Herbicides in Water
379
379
Fig. 7. Total ion and SIM chromatograms of the six chlorinated phenoxy acid herbicides: (A) Total ion chromatograms are obtained using
dibutylamine acetate (DBA) as ion-pairing reagent. Eluents A (water) and B (acetonitrile) containing 5 mmol/L DBA. Linear gradient from 30%
B/A to 85% B/A in 15 min, 15 min reequilibration. (B) SIM chromatograms are obtained by in-tube SPME–LC–MS of river water spiked with
0.05 ng/mL. Peaks: 1, MCPA; 2, 2,4-D; 3, dichlorprop; 4, 2,4,5-T; 5, 2,4-DB; 6, 2,4,5-TP. From ref. 26 with permission.
380
Kataoka, Mitani, and Takino
Fig. 8. Chromatogram of water sample spiked with 10 ng/mL standard triazine herbicides
obtained in MRM in positive ionization mode by in-tube SPME–LC–MS/MS. Peaks: 1, simazine (m/z 201.93 → 131.95); 2, atrazine (m/z 215.90 → 173.95); 3, ametryne (m/z 228.04 →
186.05); 4, propazine (m/z 229.93 → 145.95); 5, prometryne (m/z 242.02 → 158.05).
26. To determine the optimal composition, different mobile phases consisting of acetonitrile–ammonium acetate were tested. A standard solution of 10 ng/mL of each triazine
herbicide used for flow injection analysis was prepared in water. The best signal was
achieved using acetonitrile–2 mM ammonium acetate (50:50 v/v). The development of
the chromatographic system was focused on short retention times and coelution of triazine herbicides, paying attention to matrix effects as well as good peak shapes. A high
proportion of organic solvent was used to coelute each substance. Thus, an increased flow
rate of 0.2 mL/min produced a good peak shape and made a runtime of 10 min possible.
27. We observed good linearity for each herbicide in the concentration range 0.05–10 ng/mL,
with correlation coefficients above 0.992. The LOD of each herbicide is in the range of
0.003–0.01 ng/mL, except for simazine (0.11 ng/mL). The in-tube SPME method shows
17–30 times higher sensitivity than the direct injection method.
28. The recoveries of herbicides spiked into water samples are each above 95%. MCPA and
2,4-D are detected in 7/30 river water samples tested. For each of these, good agreement
is obtained between in-tube SPME–LC–MS and other methods, including SPE–GC–MS
and SPE–HPLC. Triazine herbicides were not detected in the environmental water
samples tested in this study.
References
1. Dearfield, K. L., McCarroll, N. E., Protzel, A., Stack, H. F., Jackson, M. A., and Waters,
M. D. (1999) A survey of EPA/OPP and open literature on selected pesticide chemicals.
II. Mutagenicity and carcinogenicity of selected chloroacetanilides and related compounds.
Mutat. Res. 443, 183–221.
In-Tube SPME–LC–MS of Herbicides in Water
381
2. Schantz, S. L. and Widholm, J. J. (2001) Cognitive effects of endocrine-disrupting chemicals in animals. Environ. Health Perspect. 109, 1197–1206.
3. Waissmann, W. (2002) Health surveillance and endocrine disruptors. Cad. Saude. Publ.
18, 511–517.
4. van der Hoff, G. R. and van Zoonen, P. (1999) Trace analysis of pesticides by gas chromatography. J. Chromatogr. A 843, 301–322.
5. Karcher, A. and El Rassi, Z. (1999) Capillary electrophoresis and electrochromatography
of pesticides and metabolites. Electrophoresis 20, 3280–3296.
6. D’Ascenzo, G., Curini, R., Gentili, A., Bruno, F., Marchese, S., and Perret, D. (2000)
Determination of herbicides in water using HPLC–MS techniques. Adv. Chromatogr. 40,
567–598.
7. Hogendoorn, E. and van Zoonen, P. (2000) Recent and future developments of liquid chromatography in pesticide trace analysis. J. Chromatogr. A 892, 435–453.
8. Sabik, H., Jeannot, R., and Rondeau, B. (2000) Multiresidue methods using solid-phase
extraction techniques for monitoring priority pesticides, including triazines and degradation products, in ground and surface waters. J. Chromatogr. A 885, 217–236.
9. Wells, M. J. and Yu, L. Z. (2000) Solid-phase extraction of acidic herbicides. J.
Chromatogr. A 885, 237–250.
10. Pico, Y., Font, G., Molto, J. C., and Manes, J. (2000) Solid-phase extraction of quaternary
ammonium herbicides. J. Chromatogr. A 885, 251–271.
11. Lee, N. A. and Kennedy, I. R. (2001) Environmental monitoring of pesticides by
immunoanalytical techniques: validation, current status, and future perspectives. J. AOAC
Int. 84, 1393–1406.
12. Beltran, J., Lopez, F. J., and Hernandez, F. (2000) Solid-phase microextraction in pesticide residue analysis. J. Chromatogr. A 885, 389–404.
13. Krutz, L. J., Senseman, S. A., and Sciumbato, A. S. (2003) Solid-phase microextraction
for herbicide determination in environmental samples. J. Chromatogr. A 999, 103–121.
14. Arthur, C. L. and Pawliszyn, J. (1990) Solid-phase microextraction with thermal desorption using fused silica optical fibers. Anal. Chem. 62, 2145–2148.
15. Kataoka, H., Lord, H. L., and Pawliszyn, J. (2000) Applications of solid-phase
microextraction in food analysis. J. Chromatogr. A 880, 35–62.
16. Lord, H. and Pawliszyn, J. (2000) Evolution of solid-phase microextraction technology. J.
Chromatogr. A 885, 153–193.
17. Alpendurada, M. de F. (2000) Solid-phase microextraction: a promising technique for
sample preparation in environmental analysis. J. Chromatogr. A 889, 3–14.
18. Pawliszyn, J. (2001) Solid-phase microextraction. Adv. Exp. Med. Biol. 488, 73–87.
19. Buldini, P. L., Ricci, L., and Sharma, J. L. (2002) Recent applications of sample preparation techniques in food analysis. J. Chromatogr. A 975, 47–70.
20. Zambonin, C. G. (2003) Coupling solid-phase microextraction to liquid chromatography.
A review. Anal. Bioanal. Chem. 375, 73–80.
21. Eisert, R. and Pawliszyn, J. (1997) Automated in-tube solid-phase microextraction coupled
to high-performance liquid chromatography. Anal. Chem. 69, 3140–3147.
22. Kataoka, H. (2002) Automated sample preparation using in-tube solid-phase
microextraction and its application—a review. Anal. Bioanal. Chem. 373, 31–45.
23. Gou, Y., Tragas, C., Lord, H. L., and Pawliszyn, J. (2000) On-line coupling of in-tube
solid-phase microextraction (SPME) to HPLC for analysis of carbamates in water samples:
comparison of two commercially available autosamplers. J. Microcol. Sep. 12, 125–134.
24. Gou, Y. and Pawliszyn, J. (2000) In-tube solid-phase microextraction coupled to capillary
LC for carbamate analysis in water samples. Anal. Chem. 72, 2774–2779.
382
Kataoka, Mitani, and Takino
25. Wu, J., Tragas, C., Lord, H., and Pawliszyn, J. (2002) Analysis of polar pesticides in water
and wine samples by automated in-tube solid-phase microextraction coupled with highperformance liquid chromatography–mass spectrometry. J. Chromatogr. A 976, 357–367.
26. Takino, M., Daishima, S., and Nakahara, T. (2001) Automated on-line in-tube solid-phase
microextraction followed by liquid chromatography/electrospray ionization–mass spectrometry for the determination of chlorinated phenoxy acid herbicides in environmental
waters. Analyst 126, 602–608.
27. Takino, M., Daishima, S., and Yamaguchi, K. (2000) Determination of haloacetic acids in
water by liquid chromatography–electrospray ionization–mass spectrometry using volatile ion-pairing reagents. Analyst 125, 1097–1102.
28. Takino, M., Daishima, S., and Yamaguchi, K. (1999) Analysis of anatoxin-a in freshwaters by automated on-line derivatization-liquid chromatography-electrospray mass spectrometry. J. Chromatogr. A 861, 191–197.
LC/LC for Pesticide Analysis
383
29
Coupled-Column Liquid Chromatography
for the Determination of Pesticide Residues
Elbert Hogendoorn and Ellen Dijkman
Summary
This chapter demonstrates the versatility and feasibility of coupled-column reversedphase liquid chromatography (LC/LC) for the rapid, selective, and sensitive determination of pesticides in environmental water samples. The work includes the setup and
application of three different methods, covering the wide polarity range of pesticides as
well as various LC/LC approaches and the important parameters and aspects to be considered in method development.
Key Words: Coupled column; liquid chromatography; pesticide residues.
1. Introduction
1.1. General Aspects
For a number of important features such as automation of sample pretreatment and
improvement of sensitivity or selectivity, column switching in liquid chromatography
(LC) has been widely adopted in the field of pesticide residue analysis. Column switching usually involves the use of two columns, which can be switched on- or off-line by
a six-port high-pressure switching valve. Basically, the first column (C-1) serves for
sample enrichment (injection) and cleanup, and the second column (C-2) provides the
(final) separation of the compound(s).
Depending on the dimension of the first column C-1, one can discriminate between
precolumn switching LC (LC/PC) or solid-phase extraction LC (SPE–LC) and
coupled-column LC, LC/LC. The major difference between these two techniques is
the type of the first column and the inherent important features dimension, particle
size, and separation power.
In SPE–LC, the first column C-1 is a small precolumn, typically 2- to 4.6-mm id
and less than 10 mm long and usually is packed with materials of a relatively large
particle size (10–40 μm) to facilitate large volumes of aqueous samples. In LC/LC, the
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
383
384
Hogendoorn and Dijkman
dimension of C-1 is that of an analytical column packed with highly efficient materials
(particle size ⱕ 5 μm).
Hence, the major difference between SPE–LC and LC/LC is the difference in separation power of C-1, which is low in SPE–LC (plate number N < 50) and high in LC/
LC (plate number N > 2000). Reviews (1–3) extensively informed on the scope (applications), the type of configurations, and new developments (trends) of LC/LC in residue analysis of pesticides and related compounds.
In environmental trace analysis of polar organic contaminants, reversed-phase liquid chromatography (RPLC) is usually confronted with an excess of polar interferences (e.g., inorganic and organic ions and degradation products of organic matter like
humic and fulvic acids). Especially for not very selective ultraviolet (UV) detection,
determination of more polar analytes eluting in the first part of the chromatogram will
be difficult or impossible.
This common situation is illustrated by the simulated chromatogram in Fig. 1, which
presents the interferences usually encountered in pesticide residue analysis employing
RPLC/UV. As indicated by S1, abundantly present early eluting sample constituents
cause the major problem. Usually, this problem is (partly) solved by a laborious
cleanup procedure.
S1 interferences can be partly removed via low-resolution cleanup, such as off-line
SPE or on-line with LC/PC. However, for analytes of type A1 with a polarity in the
range of the excess of interferences, such a cleanup will not provide sufficient selectivity with UV detection. For mass spectrometric (MS) or tandem mass spectrometric
(MS/MS) detection, selectivity will be distinctly less influenced. However, the presence of an excess of matrix compounds can severely affect the ionization efficiency,
which will usually result in signal suppression of the analytes, making reliable quantification difficult. Studies clearly demonstrated the improvement in MS detectability
and quantification of analytes when using LC/LC for on-line cleanup of water samples
(4) or plant extracts (5,6).
The two remaining type of interferences, S2 and S3, are usually controlled by optimizing (changing) chromatographic conditions. For example, a separation between S2
and A3 might be achieved by tuning the LC selectivity with a change in eluotropic
strength ϕ or type of modifier. Extension of the run time caused by a late-eluting S3
interference can be (partly) reduced by a fast, steep gradient, started after the elution
of A3. Note that such a step also consumes additional analytical time for reconditioning the separation column prior to the next injection. Reversed-phase coupled-column
LC (LC/LC) can effectively remove interferences of type S1 and S3.
1.2. Development of an Analytical Method Using LC/LC
The scheme of a reversed-phase LC/LC system is presented in Fig. 2. In comparison to the back-flush column-switching SPE–LC technique, schematically shown in
Fig. 3 (see Note 1), LC/LC is a forward-flush, column-switching, heart-cutting technique. As shown in Fig. 2, it consists of three different steps to perform on-line cleanup
and analysis of aqueous samples or extracts.
LC/LC for Pesticide Analysis
385
Fig. 1. Simulated chromatogram usually encountered in the RPLC/UV pesticide residue
analysis of environmental samples. A1, A2, and A3, eluting target compounds; S1, S2, and S3,
types of sample interferences (for further explanation, see text).
Step 1 involves the injection of an aliquot of uncleaned aqueous sample or extract
onto the first column C-1, followed by a cleanup with a certain volume of M-1, the
cleanup volume, which removes from C-1 a large part of S1 interferences with the
mobile phase M-1.
In Step 2, just before the elution of the (first) analyte A1, takes place, C-1 is
switched on-line with the second separation column C-2 during a time that the fraction
containing the analyte(s) (the transfer volume) is completely transferred from C-1 to C-2.
Finally, in Step 3, the analytes A1, A2, and A3 are separated on C-2, and simultaneously the remaining part of S1 interferences as well as that of type S3 will be washed
from C-1 with M-1 or a stronger eluent and reconditioned with a volume of M-1 prior
to the next injection.
The procedure in LC/LC method development is straightforward and usually includes a number of consecutive steps as schematically presented in Fig. 4. First, information must be obtained regarding whether sufficient sensitivity will be available with
the selected detection mode, which in most cases will be UV detection, MS detection,
or fluorescence detection (FLD). Without sufficient sensitivity, the setup of an LC/LC
method is not feasible. If information on detectability is not available, preliminary
experiments will be necessary (e.g., in case of MS detection, by infusion experiments
386
Hogendoorn and Dijkman
Fig. 2. Schematic presentation of the three steps applied in the forward-flush, heart-cutting,
column-switching technique of coupled column LC (LC/LC). M-1 and M-2, first and second
mobile phase, respectively; C-1 and C-2, first and second analytical separation column, respectively; HV, six-port high-pressure switching valve; AS, autosampler; S, S1, and S3, interferences (see Fig. 1); A, A1, A2, and A3, target compounds (see Fig. 1); D, detector; W, waste.
LC/LC for Pesticide Analysis
387
Fig. 3. Schematic presentation of the third step applied in the backflush, column-switching
LC/SPE technique. M-1 and M-2, first and second mobile phase, respectively; C-1 and C-2,
first and second analytical separation column, respectively; HV, six-port high-pressure switching valve; AS, autosampler; S1 and S3, interferences (see Fig. 1); A1, A2, and A3, target compounds (see Fig. 1); D, detector; W, waste.
with standard solutions in a suitable buffer). Unfortunately, only a few pesticides have
a favorable native fluorescence property. Hence, the selection of FLD usually depends
on the reactivity of the pesticide(s) with a suitable fluorogenic label, such as 9fluoronylmethylchloroformate (FMOC-Cl) and o-phthalaldehyde. Regarding UV detection, the sensitivity depends on the value of the molar extinction coefficient ε
(L.mol-1.cm-1) at a suitable wavelength λ (nanometers). The molar extinction coefficient (ε) of a species is defined by the equation A = εbc, where A is the absorbance of
the solution, b is the path length, and c is the concentration of the species. This information can easily be calculated from the data of the peak in the RPLC chromatogram
(see Note 2). In our experience in the analysis of pesticides in water samples, UV
detection becomes feasible with values for ε and λ above 2000 L.mol-1.cm-1 and 200
nm, respectively.
The next important parameter to be considered is the retention on a C18 silica-bonded
phase. Based on our experience, the k value of the compound on the C18 column with
pure water as the mobile phase must be above 1 to aim at a successful LC/LC procedure.
As indicated in Fig. 4, the next steps involve the selection of columns and the establishment of suitable chromatographic conditions on the first and second columns.
These experiments will be done without the use of the high-pressure switching valve
(HV), and the outlet of the separation column (C-1 or C-2) will be directly connected
to a detector. C-1 must provide sufficient separation to remove a major part of the
abundantly present early eluting matrix constituents prior to elution of the analyte.
Therefore, a column with high separation power is attractive. However, an unnecessary increase of separation power and dimension of the column must be avoided. First,
the peak elution volume of the analyte should be kept as low as possible. Second, an
increase of the column dimension will also increase the reconditioning time of C-1
between analyses. As a rule of thumb, the eluotropic strength of M-1 should be selected in such a way that the capacity factor of the analyte is in the range of 1 < k < 5,
388
Hogendoorn and Dijkman
Fig. 4. Scheme of straightforward LC/LC method development in the trace analysis of
pesticides.
LC/LC for Pesticide Analysis
389
rendering a cleanup volume of at least two times the dead volume of the column V0 to
remove a large part of the excess of early eluting interferences.
Especially in the analysis of compounds with little C18 retention, it is favorable to
select a second column (C-2) with a higher separation power than C-1. This provides
flexibility when optimizing the eluotropic strength of M-2 to reach an adequate compromise between the required separation efficiency on the second column and the desired peak compression (sensitivity of detection). The favorable feature of peak
compression obtained by a step-gradient elution in column switching is a result of an
increase in eluotropic strength ϕ (fraction of organic modifier) of the mobile phase on
C-1. This favorable process has been clearly described and visualized (7,8). It must be
emphasized here that the ϕ of M-1 never must exceed the ϕ of M-2 (ϕM-1 < ϕM-2) to
avoid unnecessary band broadening of the compounds. For the selection of C-2, one
should not overkill separation power. As a rule of thumb and to achieve fast analysis
and good sensitivity, the capacity factor of the analyte(s) on C-2 should not exceed 15.
Especially for UV detection, one selects the same modifier (methanol, acetonitrile, or
mixtures) for both mobile phases (M-1 and M-2) and minimizes the size of the step
gradient (viz. the difference in eluotropic strength of two eluents) to minimize baseline
distortion in the chromatogram.
After the selection of adequate conditions, the attainable sensitivity is determined
by large-volume injection (LVI) of standard solutions in high-performance liquid chromatography (HPLC)-grade water or buffer (see Note 3). This is done by connecting C1 to the UV detector, which simultaneously provides the values for cleanup volume
and transfer volume, as illustrated in Fig. 5.
The maximum allowable sample injection volume, that is, the volume that can be
injected without excessive band broadening during injection, largely depends on the
C18 retention of the analyte. To maximize sample injection volume for the analysis of
acidic pesticides, the initial pH of the mobile phase should be as low as possible for
stationary phases based on modified silica’s typically are around pH 2.5. Special attention must be paid to analytes with little C18 retention, such as ethylenethiourea
(ETU; main metabolite of maneb and zineb), with a k value of 1.2 in pure water as the
mobile phase. Such a property makes top-column focusing of the analyte impossible,
and because of migration of ETU during injection, band broadening rapidly starts to
increase with increasing injection volume. In general, the start of peak deformation of
the analyte on injection on C-1 is selected as a criterion for the maximum allowable
injection volume.
If sufficient sensitivity cannot be obtained with an LVI below 10 mL, an off-line
concentration step will be necessary. An example of this approach involving the processing of extracts with LC/LC is shown in the second method (see below). After the
selection of suitable conditions, the LC/LC method is applied to the analysis of reallife environmental samples or extracts. Of course, depending on the type of sample
and the site of sampling, the concentration and nature of the ionic and/or highly polar
interferences can vary strongly. During this part of the optimization one can, if required, tune selectivity by choosing another type of hydrophobic column packing material or one from a different manufacturer or, in most cases, firstly, by changing the
390
Hogendoorn and Dijkman
Fig. 5. Simulated chromatogram of an injection of a standard solution on C-1 connected to
the detector for the selection of LC column-switching conditions. A–B, injection volume; A–C,
cleanup volume; C–D, transfer volume.
mobile phase constituents such as type of modifier, buffer and pH. As shown in the
determination of ETU in various types of ground water (9), increasing the separation
power of C-1 is most efficient for very polar compounds.
In the RPLC/UV analysis of acidic compounds employing a buffer at low pH (<4),
no modifier gradient should be used because these will result in a large interfering peak
(hump) caused by a release of humic and fulvic acids from the column during the gradient; it is demonstrated that the use of pH-based gradients offers higher selectivity (10).
2. Materials
2.1. Reagents
1. Pesticides (purity > 99%) (e.g., Dr. S. Ehrenstorfer, Promochem, Wesel, Germany).
2. HPLC-grade acetone, acetonitrile, methanol, and pure water.
3. Phosphoric acid (89% pure), hydrochloric acid (37% pure), and trifluoroacetic acid (TFA;
99% pure).
LC/LC for Pesticide Analysis
391
4. Analytical-grade potassium hydroxide, potassium dihydrogen phosphate, and disodium
tetraborate decahydrate.
5. FMOC-Cl.
2.2. Equipment
1. HPLC column-switching system (Fig. 2), basically consisting of two LC pumps (flow set
at 1 mL/min); an autosampler (AS); a six-port HV; two analytical reversed-phase columns (C-1 and C-2); a detector (D; UV, MS, or fluorescence); and a recorder or integrator
for quantitative measurements of the peak heights.
2. 3-mL SPE cartridges containing 500 mg 40 μm C18-bonded silica.
3. A 50 × 4.6 mm id and 100 × 4.6 mm id column packed with 3-μm C18 as C-1 and C-2,
respectively, for Method 1.
4. A 50 × 4.6 mm id column packed with 3-μm C18 as C-1 and a 150 × 4.6 mm id column
packed with 5-μm SPS-5PM-S5-100-ODS as C-2 for Method 2. (SPS, semipermeable
surface; S5, sperical 5 μm particle; ODS, octadecyl silane.)
5. A 30 × 4.6 mm id column packed with 5-μm C18 as C-1 and a 250 × 4.6 mm id column
packed with 5-μm Hypersil APS (NH2) as C-2 for Method 3.
2.3. Solutions and Mobile Phases
1. Stock standard pesticide solutions (~500 μg/mL) are made in acetonitrile or methanol.
Dilutions are made in HPLC-grade water.
2. 0.05 M phosphate buffer, pH 5.7, prepared by dissolving 6.803 g potassium dihydrogen
phosphate in water and adjusting pH with a 2 M potassium hydroxide solution.
3. 0.05 M disodium tetraborate, pH 9.0, solution in HPLC-grade water.
4. 0.025 M disodium tetraborate, pH 9.0, solution in HPLC-grade water.
5. FMOC-Cl solution of 2000 μg/mL in acetonitrile.
6. Mobile phase (M-1 and M-2) of acetonitrile–water (48:52 v/v) for Method 1 (isoproturon).
7. Mobile phase (M-1) of acetonitrile–0.03 M phosphate buffer, pH 2.4 (35:65 v/v), and a
mobile phase (M-2) of acetonitrile-0.03 M phosphate buffer, pH 2.4 (40:60 v/v), for
Method 2 (bentazone and bromoxynil).
8. Mobile phase (M-1 and M-2) of acetonitrile-0.05M phosphate buffer, pH 5.7 (35:65 v/v),
for Method 3 (glyphosate and aminomethylphosphonic acid [AMPA]).
3. Methods
Three LC/LC methods for the rapid analyses of various pesticides in water samples
involving on-line and off-line approaches are presented below. Information on the
pesticides analyzed with the three selected methods is given in Table 1. As can be
seen from this table, the three methods involve the trace analysis of (1) a rather neutral
compound (isoproturon), (2) acidic compounds (bentazone and bromoxynil), and (3)
amphoteric/ionic compounds (glyphosate and AMPA), thus covering a wide polarity
range in the determination of pesticides.
3.1. Determination of Isoproturon
This application deals with the direct LC/LC/UV trace analysis of a phenyl ureum
herbicide (isoproturon) in water. Phenyl urea herbicides form a group of compounds
with favorable RPLC properties, such as sufficient C18 retention, and good elution
performance without the use of a buffer. Sensitive detection is possible with both UV
and MS, making a combination with RPLC the preferred technique of analysis.
392
Hogendoorn and Dijkman
Table 1
Information for Selected Methods and Pesticides
Method
Pesticide
Chemical family
pKa
3.1.
3.2.
Isoproturon
Bentazone
Bromoxynil
Glyphosate
Urea
Benzothiadiazole
Hydroxybenzonitrile
Phosphonic acid
AMPA
Phosphonic acid
n.a.
3.3
3.86
0.78
2.29
5.59
n.a.
3.3.
Solubility
in water (mg/L)
65
570
130
12,000
>100,000
n.a., information not available.
The high selectivity of MS and moreover of tandem mass spectrometric detection
(MS/MS) offers the possibility to perform quantification and identification simultaneously in one run. However, low-cost and robust UV detection can be a very attractive technique in monitoring studies involving a limited number of target pesticides to
be analyzed in a large number of environmental samples with a low expectation to find
positive samples.
3.1.1. Method Development
According to the scheme of Fig. 4, the following considerations and steps are made
in LC/LC/UV method development:
1. Isoproturon has a good UV detectability (ε of about 20,000 L/mol.cm at about 244 nm).
2. With a k value of about 5 in a mobile phase of methanol–water (50:50 v/v), the C18
retention can be considered high. This means that there is top-column focusing of the
analyte during the injection of a large volume of water sample.
3. Having sufficient C18 retention, a short cartridge column (50 × 4.6 mm id) packed with
3-μm C18 is selected as C-1. To enhance somewhat the separation power, a 100 × 4.6 mm
id column with the same material is used for C-2. A cartridge housing system favors the
flexibility of including a guard column before C-1.
4. Regarding the modifier of the mobile phase, acetonitrile is preferred above methanol because of slightly improved peak shape and a decrease in column pressure. For both M-1
and M-2, a mobile phase of acetonitrile–water (48:52 v/v) is selected, providing a k value
of 4.1 for isoproturon.
5. A sample injection volume of 4.0 mL is selected to provide the required 0.1-μg/L limit of
detection for isoproturon in water.
6. Selecting a 5.85-mL cleanup volume and a 0.45-mL transfer volume as accurately adjusted column switching conditions (see Fig. 5), it appeared that the LC/LC method is
suitable for the analysis of isoproturon in surface and ground water samples.
3.1.2. Analytical Procedure (see Note 4)
1. Inject a 4.0-mL volume of water sample on C-1.
2. After cleanup with 5.85 mL M-1 (injection volume included), switch C-1 on-line with C2 for 0.45 min for the transfer of the analyte containing fraction to C-2.
LC/LC for Pesticide Analysis
393
3. Do quantification of isoproturon by external calibration with standard solutions of the
analytes in pure water, with UV detection at a wavelength of 244 nm.
3.2. Determination of Bentazone and Bromoxynil
This application involves multimodal LC/LC employing an analytical C18 column
and an analytical column packed with efficient restricted-access material (RAM). This
material combines two different selectivities in one column, that is, size exclusion of
large molecular compounds and an efficient separation of the target compounds. The
use of such a column in environmental analysis in LC/LC for the trace analysis of
acidic pesticides is attractive to exclude (remove) large molecular weight compounds,
such as dissolved organic compounds like humic and fulvic acids (11–15) (see Note
5). The major problem encountered in the trace analysis of acidic pesticides in water
samples is visualized in Fig. 6. This figure clearly shows that the sampling at low pH
of 100 mL of groundwater on a 100-mg SPE C18 cartridge results in a large increase
of coextracted acidic interferences in comparison to the sampling at a neutral pH. In
the RPLC analysis of acidic compounds involving a buffer at low pH (<4.0), the
coextracted humic acid interferences always show up in the chromatogram as a big
hump, obscuring the analytes at low levels and making quantification difficult.
3.2.1. Method Development
According to the scheme of Fig. 4 and to the information given in ref. 14, the
following considerations and steps are made in method development:
1. Bromoxynil and bentazone can be sensitively detected by UV detection (ε of about 22,000
L/mol.cm) at a wavelength of 217 nm.
2. The C18 retention of both compounds is considerably high (comparable to that of isoproturon)
when using a buffer at low pH (2.4) as the aqueous constituent of the mobile phase.
3. The RPLC/UV characteristics of both bromoxynil and bentazone are attractive for investigation of the feasibility of the direct analysis of water samples with LVI. The injection
of about 3–4 mL of sample should be sufficient to reach the 0.1-μg/L (ppb) level. However, this project involved the sampling before, during, and after agricultural applications
of the herbicides. To encompass this period of several months, it was decided to apply SPE
shortly after the arrival of samples and to analyze batches of extracts (see Subheading 3.2.2.).
4. As applied for isoproturon, the feasibility of the two cartridge columns (50 × 4.6 and 100
× 4.6 mm id) packed with 3-μm C18 for C-1 and C-2 was investigated. Rendering adequate k values of the acidic pesticides and providing some additional peak compression
for the enhancement of sensitivity, mixtures of acetonitrile–phosphate buffer, pH 2.4, of
35:65 (v/v) and 40:60 (v/v) were selected for M-1 and M-2, respectively.
5. Using an injection volume of 200 μL of the SPE extract to reach the required limit of
detection of 0.05 μg/L, the cleanup and transfer volumes are precisely determined. Unfortunately, as a result of an elevated background signal (hump) of the transferred interferences of these samples, the LC/LC method with the two C18 columns did not provide
sufficient selectivity to reach the required sensitivity.
6. The feasibility of a RAM column is investigated. As a rule of thumb, separation power of
both columns is minimized to speed analysis. However, available precolumns packed
with RAM materials did not provide sufficient retention or resulted in too much band
broadening of the analytes (14). At the time of method development, only a 150 × 4.6 mm
394
Hogendoorn and Dijkman
Fig. 6. Two RPLC/UV (228 nm) chromatograms of extracts of a groundwater sample
obtained after loading of 25 mL sample adjusted at pH 7.0 and pH 2.0 on 100-mg C18 SPE
cartridges. After evaporating the 1 mL of acetone used for desorption, the residue is redissolved in 1 mL 0.05% aqueous TFA. Injection of 100 μL of extract on a 3 μm C18 column (100
× 4.6 mm id) and a mobile phase of methanol–0.05% TFA in water (60:40 v/v) at 1 mL/min.
id RAM analytical column packed with 5-μm SPS-ODS material was available. To apply
cleanup, the use of a RAM column as C-1 in LC/LC seems to be more adequate. However, the length of the available column makes this configuration unsuitable. Time for
cleanup and transfer will be unnecessarily long, and the exposure of such an expensive
column to the injection of uncleaned extracts is not attractive. Therefore, the analytical
SPS column is used as C-2 in combination with the 50 × 4.6 mm id 3-μm C18 column as
C-1. This C18/SPS column combination provided the required selectivity to analyze these
types of water samples at the required sensitivity.
3.2.2. Analytical Procedure (see Note 6)
1. Precondition the SPE cartridges with 3 mL methanol, acetone, and methanol and 6 mL
0.1% phosphoric acid in water.
2. Bring a 200-mL water sample to pH 2.1 (±0.1) with 200 μL TFA and percolate through
the preconditioned cartridge at a flow rate of approx 4 mL/min.
LC/LC for Pesticide Analysis
395
3. After sample loading, dry the cartridge by passing air for 20 min.
4. Transfer the cartridge above a calibrated tube and, by means of slight overpressure, pass
2 mL acetone through the cartridge and collect in the tube.
5. Evaporate, prior to the LC analysis, the acetone extract to dryness using a warm water
bath and a gentle stream of nitrogen.
6. Redissolve the residue by first adding 400 μL acetonitrile, followed by 1600 μL 0.1%
phosphoric acid in water (see Note 7).
7. Inject a 200-μL volume obtained after the SPE procedure on C-1.
8. Switch, after cleanup with 2.9 mL M-1 (injection volume included), C-1 on-line with C2 for 0.90 min for the transfer of the analyte containing fraction to C-2.
9. Do the quantification of bentazone and bromoxynil by external calibration with standard
solutions of the analytes in acetonitrile–0.1% phosphoric acid in water (20:80 v/v) with
UV detection at a 217-nm wavelength.
3.3. Determination of Glyphosate and AMPA
This application is a successful multimodal LC/LC method developed for the efficient residue analysis of the highly polar phosphonic acid herbicides glufosinate and
glyphosate and glyphosate’s major metabolite AMPA in water, soil, and plant materials (16–21). As reviewed (22), the sample pretreatment procedures in conventional
analytical methodologies still in use are very laborious for obtaining sufficient sensitivity and selectivity. In the early 1990s, an original methodology employing LVI and
multimodel LC/LC was developed that eliminated almost completely the existing laborious sample pretreatment procedures (see Note 8).
3.3.1. Method Development
According to Fig. 4 and published information (16–22), the following steps in
method development have been made:
1. Phosphonic herbicides like glyphosate and glufosinate are small molecules without a chromophore suitable for UV or FLD detection. For sensitive and selective detection, the
technique of precolumn derivatization with FMOC-Cl is selected. The final solution of
the formed FMOC–glyphosate and FMOC–AMPA is a 2.5-mL mixture of acetonitrile–
borate buffer (20:80 v/v).
2. Because of the required ion exchange chromatography on C2, the suitable LC conditions
on C-1 are determined by the required conditions on C-2. Changes in mobile phase composition as a result of column switching can severely affect the stability of the ion exchange retention of analytes. Therefore, the mobile phase consisting of acetonitrile–0.05M
phosphate buffer, pH 5.7 (35:65 v/v) is used on both columns.
3. Regarding separation power, C-1 must perform an efficient preseparation between the
very-fast-eluting derivatives and the less-polar excess of formed FMOC–OH reagent. In
addition, an LVI should be performed to obtain sufficient sensitivity without the necessity of a tedious off-line concentration step. As indicated below, these conditions can be
adequately obtained on a short 30 × 4.6 mm id column packed with 5-μm C18 material.
4. Because of the high percentage of acetonitrile (elution power), LVI of the solution
obtained after derivatization will lead to excessive band broadening of the compounds
during injection. This problem could be resolved by diluting the solution with aqueous
buffer prior to injection. A fourfold dilution is sufficient to provide fully top-column
focusing of the compounds during injection (up to 2 mL of diluted solution).
396
Hogendoorn and Dijkman
Fig. 7. Establishment of LC/LC column-switching conditions for the LC/LC/FLD analysis
of glyphosate and AMPA. Injection of 2.0 mL of a standard solution obtained after
derivatization and dilution. C-1, 30 × 4.6 mm id column packed with 5 μm C18 material, directly connected to FLD; mobile phase (M-1), acetonitrile–0.05 M phosphate buffer, pH 5.7
(35:65 v/v) at 1 mL/min.
5. Selecting a 2.0-mL sample injection volume to obtain sufficient sensitivity, the cleanup
and transfer volumes are determined by performing LVI on C-1 connected to the FLD.
The result of this experiment is displayed in Fig. 7. It nicely illustrates the top-column
focusing of the analytes during the 2-mL injection of sample solution, followed by the
elution as (almost) unretained analytes.
Under the selected column-switching conditions, the LC/LC/FLD method appeared
to be very adequate and efficient for the fast processing of extracts of different types
of soils and foodstuffs obtained after extraction, derivatization, and dilution.
3.3.2. Analytical Procedure (see Note 9)
1. Transfer a 1.5-mL volume of water sample into a glass tube together with 0.5 mL 0.05 M
borate buffer (pH 9.0) and follow by 0.5 mL FMOC-Cl solution (2000 μg/mL).
2. Shake the tube and leave for 30 min at room temperature.
3. Add 7.5 mL of 0.025 M borate buffer to dilute this solution.
4. Inject 2.00 mL of the final solution on C-1.
5. After cleanup with 2.42 mL M-1 (injection volume included), switch C-1 on-line with C2 for 0.35 min to transfer the fraction containing both glyphosate and AMPA derivates to C-2.
6. Do the quantification of the analytes by external calibration with standard solutions in
water processed with the precolumn derivatization procedure with an FLD set at 263
(excitation) and 317 nm (emission).
LC/LC for Pesticide Analysis
397
4. Notes
1. As indicated in Fig. 2, LC/LC is (almost) always performed in the forward-flush mode.
The main reason is to fully maintain the separation of analytes on C-1 and to avoid (partly)
nullification of this separation by running it again on C-1 in a reverse direction. SPE–LC
is preferably performed in the back-flush mode. The different connection of the SPE–LC
mode is displayed in Fig. 3. SPE–LC aims at fully top-column focusing of the analytes on
the precolumn, thus avoiding unwanted additional band broadening of the analytes by
transport through the less-efficient large-size column-packing material. Obviously, the
cleanup performance of SPE–LC regarding removal of S1 interferences will be distinctly
less compared to LC/LC (see also Fig. 3).
2. Assuming a Gaussian peak shape and performing an isocratic elution, the molar extinction coefficient ε can be calculated from the peak in the chromatogram requiring the
following information:
Description
Symbol
Flow of the mobile phase
F
Half the peak width at 0.6 of the peak height
σ
Injection volume
V0
Concentration of the injected compound
C0
UV absorption of the compound
E
Path length of the flow cell of the UV detector
b
The dilution D of the compound in the flow cell is given by the equation
D = (F ∗ σ ∗ (2 ∗ Π)1/2)/V0
Unit
mL/min
min
mL
mol/L
AU
cm
(1)
The concentration of the compound (moles/liter) in the flow cell corresponding with the maximum of the Gaussian peak is given by the equation
C = C0/D
(2)
The molar extinction coefficient ε of the compound at the given wavelength is given by the
Lambert–Beer equation:
E=ε∗b∗C
(3)
Combining Eqs. (1)–(3) gives the value of ε by the equation
ε = (E ∗ F ∗ σ ∗ (2 ∗ Π)1/2)/(b ∗ C0 ∗ V0)
3. The high sample throughput of LVI-LC/LC originates from the fact that the sample injection is performed in the high-pressure mode with an autosampler equipped with a largevolume loop and a syringe pump. To perform efficient injection, a visible air gap is
inserted at the front and end of the sample by the injector. This adequately replaces the
three-times loop filling required for accurate injection, providing a fast and accurate LVI
with minimal consumption of sample. For acidic analytes, before injection the pH value
of the sample must always be brought about 2 units below the pKa value of the analyte(s).
4. The performance of the LC/LC procedure and the inherent important features of this technique are clearly demonstrated in Fig. 8. It must be emphasized that one would not expect
such an improvement in selectivity of homomodal LC/LC using columns of similar selectivity. The multidimensional effect of LC/LC obtained by the efficient removal of the
excess of matrix compounds allows the direct trace analysis of target analytes in aqueous
398
Hogendoorn and Dijkman
Fig. 8. Selectivity and sensitivity performance of the on-line homomodal LVI-LC/LC (244
nm) of a surface water sample spiked with isoproturon at a level of 0.50 μg/L (ppb) and indicating the applied volumes for injection (4.0 mL), cleanup (5.85 mL), and transfer (0.45 mL). C1, 50 × 4.6 mm id column packed with 3 μm C18; C-2, 100 × 4.6 mm ID column packed with 3
μm C18; M-1 and M-2, acetonitrile–water (48:52 v/v) at 1 mL/min; dashed line corresponds to
the chromatogram obtained using the two columns connected in series without column switching.
LC/LC for Pesticide Analysis
5.
6.
7.
8.
9.
399
samples in less than 10 min with nonselective UV detection. This application is an example of a single-residue method using a small transfer volume (typically < 1.0 mL),
providing high selectivity. As shown in Fig. 1, the major problem concerns S1, the excess
of early eluting interferences in the first part of the chromatogram. Obviously, in case of
compounds with sufficient C18 retention (e.g., analytes of type A2 and A3), the separation power of C-1 eliminates the major part of the type S1 interferences. For such applications, an increase in transfer volume does not significantly affect the selectivity. This is
clearly demonstrated for the multiresidue analysis of triazine herbicides (23), carbamate
pesticides (24), and phenylurea herbicides (25) in environmental water samples, using
the same LC/LC-UV approach and transfer volumes of 2.0, 5.9, and 10 mL, respectively.
RAM columns in LC/LC modes can greatly enhance the cleanup. Successful applications
have been developed for the analysis of acidic pesticides in soils (11,12) and water
(13,14). Method development strategies for using various types of analytical RAM columns as regards the type of packing material and separation power (dimension) and the
use in various types of LC/LC modes have been described (15). The comprehensive study
revealed that the combination of one analytical RAM column with a C18 column is most
favorable in this field of analysis (15).
The multidimensional effect clearly shown in Fig. 9 makes it possible to determine the
compounds to a level of 0.05 μg/L (ppb) in difficult types of surface water samples. As
regards the total separation power of the two columns, the chromatographic analysis is
significantly improved when LC/LC (with column switching) is used instead of only LC
(without column switching).The combination of off-line SPE and the fast instrumental
analysis of uncleaned extracts (less than 15 min) provides an efficient procedure with a
high sample throughput.
After SPE and evaporation of the organic solvent, the obtained residue must be redissolved
properly into an aqueous phase suitable for RPLC. This is always done by first adding the
volume of the organic modifier (acetonitrile or methanol) followed by the volume of water.
This methodology is based on an unusual multimodal LC/LC approach first developed
for the rapid determination of glufosinate in environmental waters (16). In this new approach, the off-line tedious concentration step and the liquid–liquid extraction procedure
after derivatization of the herbicides with FMOC-Cl followed by the instrumental analysis is replaced by a rapid on-line LVI-LC/LC/FLD procedure. In the LC/LC method, the
powerful cleanup on C-1 is performed in a reversed way. Normally, the first step in LC/
LC (see Fig. 2) is focused on the removal of an excess of the early eluting interferences
(S1) and the transfer of a fraction containing the analyte(s) with sufficient C18 retention.
The powerful cleanup performance of the new approach is obtained by advantageously
using the amphoteric properties of the analytes and the unusual way of heart cutting. The
ionized analytes will have very little C18 retention on C-1 and adequate retention on C-2,
having a different (ion exchange) retention mechanism. The efficient cleanup is now
obtained by transferring an almost-unretained small analyte-containing fraction, typically
200–250 μL, from C-1 to C-2. All interferences with more C18 retention (e.g., the excess
of FMOC–OH) are retained on C-1 and sent to waste by the rinsing mobile phase during
the separation of the analyte(s) on C-2.
The combination of a very simple sample pretreatment and the developed multimodal
LC/LC/FLD method provides a very efficient methodology for the analysis of phosphonic
acid herbicides in environmental waters with a high sample throughput. The performance
of this approach is illustrated Fig. 10, showing the LVI-LC/LC/FLD analysis of a surface
400
Hogendoorn and Dijkman
Fig. 9. Performance of multimodal LC/LC (217 nm) of 200 μL extract obtained after offline SPE of a ditch water sample spiked with bentazone and bromoxynil at a level of 0.50 μg/L
(ppb) with indication for the applied volumes for cleanup (2.90 mL) and transfer (0.90 mL). C1, a 50 × 4.6 mm id column packed with 3 μm C18; C-2, a 150 × 4.6 mm id column packed with
5 μm SPS RAM material; M-1, acetonitrile–0.03 M phosphate buffer, pH 2.4 (35:65 v/v) at 1
mL/min; M-2, acetonitrile–0.03 M phosphate buffer, pH 2.4 (40:60 v/v) at 1 mL/min; dashed
line corresponds to the chromatogram obtained using M-2 and the two columns connected in
series without column switching.
water sample after derivatization and dilution and containing both AMPA (1.0 μg/L) and
glyphosate (7.5 μg/L). Besides the analysis of environmental waters (16,18,21), the meth-
LC/LC for Pesticide Analysis
401
Fig. 10. Multimodal LC/LC/FLD (μex/μem, 263/317 nm) of a 2-mL injection of a surface
water sample obtained after derivatization with FMOC and dilution and containing glyphosate
(7.5 μg/L) and AMPA (1.0 μg/L). C-1, 30 × 4.6 mm id column packed with 5 μm C18; C-2, 250
× 4.6 mm id column packed with 5 μm Hypersil NH 2; M-1 and M-2, acetonitrile–0.05M phosphate buffer, pH 5.7 (35:65 v/v), both at 1 mL/min. For cleanup and transfer volume, see Fig. 7.
odology with a high sample throughput has been successfully applied to other matrices,
such as soils (17) and plant materials (19,20).
References
1. Hogendoorn, E. A. and van Zoonen, P. (2000) Recent and future developments of liquid
chromatography in pesticide trace analysis. J. Chromatogr. A 892, 435–453.
2. Hogendoorn, E. A. (2000) High-performance liquid chromatographic methods in pesticide residue analysis, in Encyclopedia of Analytical Chemistry (Meyers, R. A., ed.), Wiley,
Chichester, UK, pp. 6264–6299.
3. Hogendoorn, E. A., van Zoonen, P., and Herández, F. (2003) The versatility of coupledcolumn LC. LC–GC Europe 16, 44–51.
4. Dijkman, E., Mooibroek, D., Hoogerbrugge, R., et al. (2001) Study of matrix effects on
the direct trace analysis of acidic pesticides in water using various liquid chromatographic
modes coupled to tandem mass spectrometric detection J. Chromatogr. A 926, 113–125.
5. Choi, B. K., Hercules, D. M., and Gusev, A. I. (2001) Effect of liquid chromatography
separation of complex matrices on liquid chromatography–tandem mass spectrometry signal suppression. J. Chromatogr. A 907, 337–342.
402
Hogendoorn and Dijkman
6. Pascoe, R., Foley, J. P., and Gusev, A. I. (2001) Reduction in matrix-related signal suppression effects in electrospray ionization mass spectrometry using on-line two-dimensional liquid chromatography. Anal. Chem. 73, 6014–6023.
7. Verhij E.R. (1993) Strategies for Compatibility Enhancement in Liquid Chromatography–
Mass Spectrometry. PhD thesis, University of Leiden, Febodruk-Enschede.
8. Gort, S. M., Hogendoorn, E. A., Dijkman, E., van Zoonen, P., and Hoogerbrugge, R. (1996)
The optimization of step-gradient elution conditions in liquid chromatography: application to pesticide residue analysis using coupled-column reversed-phase LC.
Chromatographia 42, 17–24.
9. Hogendoorn, E. A., van Zoonen, P., Brinkman, U. A. T. (1991) Column-switching RPLC
for the trace-level determination of ethylenethiourea in aqueous samples. Chromatographia 31, 285–292.
10. Hogendoorn, E. A. and van Zoonen, P. (1995) Coupled-column reversed-phase liquid chromatography in environmental analysis. J. Chromatogr. A 703, 149–166.
11. Parrilla, P., Kaim, P., Hogendoorn, E. A., and Baumann, R. A. (1999) An internal surface
reversed phase column for the effective removal of humic acid interferences in the trace
analysis of mecoprop in soils with coupled-column RPLC-UV. Fresenius J. Anal. Chem.
363, 77–82.
12. Hogendoorn, E. A., Huls, R., Dijkman, E., and Hoogerbrugge, R. (2001) Microwave assisted solvent extraction and coupled-column reversed-phase liquid chromatography with
UV detection. Use of an analytical restricted-access-medium column for the efficient
multi-residue analysis of acidic pesticides in soils. J. Chromatogr. A 938, 23–33.
13. Martínez Fernández, J., Martínez Vidal, J. L., Parrilla Vázquez, P., and Garrido Frenich,
A. (2001) Application of restricted-access-media column in coupled-column RPLC with
UV detection and electrospray mass spectrometry for determination of azole pesticides in
urine. Chromatographia 53, 503–509.
14. Hogendoorn, E. A., Westhuis, K., Dijkman, E., et al. (1999) Semi-permeable surface analytical reversed-phase column for the improved trace analysis of acidic pesticides in water
with coupled-column reversed-phase liquid chromatography with UV detection. Determination of bromoxynil and bentazone in surface water. J. Chromatogr. A 898, 45–54.
15. Hogendoorn, E. A., Dijkman, E., Baumann, R. A., Hidalgo, C., Sancho, J. V., and
Hernández, F. (1999) Strategies in using analytical restricted access media columns for
the removal of humic acid interferences in the trace analysis of acidic herbicides in water
samples by coupled column liquid chromatography with UV detection. Anal. Chem. 71,
1111–1118.
16. Sancho, J. V., López, F. J., Hernández, F., Hogendoorn, E. A., and van Zoonen, P. (1994)
Rapid determination of glufosinate in environmental water samples using 9fluoronylmethoxycarbonyl precolumn derivatization, large-volume injection and coupledcolumn liquid chromatography J. Chromatogr. A 678, 59–67.
17. Sancho, J. V., Hidalgo, C., López, F. J, Hernández, F., Hogendoorn, E. A., and Dijkman,
E. (1996) Rapid determination of glyphosate residues and its main metabolite AMPA in
soil samples by liquid chromatography. Int. J. Environ. Anal. Chem. 62, 53–63.
18. Sancho, J. V., Hernández, F., López, F. J, Hogendoorn, E. A., Dijkman, E., and van
Zoonen, P. (1996) Rapid determination of glufosinate, glyphosate and aminomethylphosphonic acid in environmental waters using precolumn fluorogenic labeling and
coupled-column liquid chromatography. J. Chromatogr. A 737, 75–83.
LC/LC for Pesticide Analysis
403
19. Hogendoorn, E. A., Ossendrijver, F. M., Dijkman, E., and Baumann R. A. (1999) Rapid
determination of glyphosate in cereal samples by means of pre-column derivatization with
9-fluorenylmethyl chloroformate and coupled-column liquid chromatography with fluorescence detection. J. Chromatogr. A 833, 67–73.
20. Hernández, F., Hidalgo, C., and Sancho, J. V. (2000) Determination of glyphosate residues in plants by precolumn derivatization and coupled-column liquid chromatography
with fluorescence detection. J. AOAC Int. 83, 728–734.
21. Hidalgo, C., Rios, C., Hidalgo, M., Salvadó, V., Sancho, J. V., and Hernández, F. (2004)
Improved coupled-column liquid chromatographic method for the determination of
glyphosate and aminomethylphosphonic acid residues in environmental waters. J.
Chromatogr. A 1035, 153–157.
22. Stalikas, C. D. and Konidari, C. N. (2001) Analytical methods to determine phosphonic
and amino acid group-containing pesticides. J. Chromatogr. A 907, 1–19.
23. Hernández, F., Hidalgo, C., Sancho, J. V., and Lopez, F. J. (1998) Coupled-column liquid
chromatography applied to the trace-level determination of triazine herbicides and some
of their metabolites in water samples. Anal. Chem. 70, 3322–3328.
24. Martínez Vidal, J. L., Parrilla Vázquez, P., and Martínez Fernández, J. (2000) Coupled
column liquid chromatography for the rapid determination of N-methylcarbamates and
some of their main metabolites in water. Chromatographia 51, 187–192.
25. Van der Heeft, E., Dijkman, E., Baumann, R. A., and Hogendoorn, E. A. (2000) Comparison of various liquid chromatographic methods involving UV and atmospheric pressure
chemical ionization mass spectrometric detection for the efficient trace analysis of
phenylurea herbicides in various types of water. J. Chromatogr. A 870, 39–50.
Analysis of Quaternary Ammonium Herbicides
405
30
On-Line Admicelle-Based Solid-Phase Extraction–Liquid
Chromatography–Ionization Trap Mass Spectrometry
for the Analysis of Quaternary Ammonium Herbicides
in Drinking Water
Dolores Pérez-Bendito, Soledad Rubio, and Francisco Merino
Summary
Ion pair admicelle-based solid-phase extraction (SPE) is proved here to be a valuable
strategy to concentrate quaternary ammonium compounds (quats; chlormequat,
mepiquat, paraquat, diquat, and difenzoquat) from drinking water. The approach is based
on the adsolubilization of quats–surfactant ion pairs on sodium dodecyl sulfate (SDS)coated alumina at pH 2.0. The on-line coupling of admicelle-based SPE to liquid chromatography (LC)–electrospray ionization trap mass spectrometry (MS/ESI) permits the
identification and quantification of quats at the levels required by the international recommended levels (0.1 µg/L). The concentration factor achieved is about 250 using 50mL sample volumes. The detection limits range from 10 to 30 ng/L. On-line regeneration
of the sorbent in each run is easily achieved by disruption of SDS admicelles with methanol and posterior coating of the alumina with SDS.
Key Words: Admicelles; chlormequat; diquat; difenzoquat; drinking water; ion trap
mass spectrometry; liquid chromatography; mepiquat; on-line LC/SPE; paraquat; pesticides; quaternary ammonium herbicides; quats; sodium dodecyl sulfate-coated alumina;
solid-phase extraction.
1. Introduction
Hemimicelles and admicelles, largely studied by physical chemists (1–10) and
applied in analytical processes to admicellar-enhanced chromatography (11) and to
the preconcentration of heavy metals from aqueous samples (12–17), have been seldom used for the extraction/concentration of organic compounds (18–21). These sorbents are formed by the adsorption of ionic surfactants on metal oxides such as
alumina, silica, titanium dioxide, and ferric oxyhydroxides. Hemimicelles consist of
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
405
406
Pérez-Bendito, Rubio, and Merino
monolayers of surfactants adsorbing head down on the opposite-charged surface of
the oxide. The formation of admicelles occurs after surface saturation by the adsorbed
surfactant. Admicelles have the structure of bilayers, with the hydrophobic interaction
of the nonpolar chain groups of the surfactants the driving force for their formation.
So, the outer surfaces of the hemimicelle and admicelle are hydrophobic and ionic,
respectively, providing a twofold mechanism for retention of organics. Benefits
obtained with the use of these sorbents have been high extraction yields, easy elution
of analytes, high breakthrough volumes, and high flow rate for sample loading (22).
An additional advantage is that there are many surfactants commercially available, so
both the degree of hydrophobicity and the charge of the sorbent can be easily modified
according to the nature of analytes.
The usefulness of these sorbents for the concentration of pesticides from environmental water samples is illustrated here for the analysis of quaternary ammonium herbicides (quats: chlormequat [CQ], mepiquat [MQ], paraquat [PQ], diquat [DQ], and
difenzoquat [FQ]) in drinking water sources and finished drinking water. The method
is based on (1) the preconcentration of quats on sodium dodecyl sulfate (SDS)
admicelles on the basis of the formation of SDS–quats ion pairs, (2) the on-line separation of quats by liquid chromatography (LC), and (3) the quantification and identification of analytes using electrospray ionization (ESI) in the positive mode/ionization
trap mass spectrometry (MS).
2. Materials
2.1. Reagents
1.
2.
3.
4.
5.
High-performance liquid chromatography-grade acetonitrile.
Heptafluorobutyric acid (HFBA) (99% pure, reagent grade)
SDS (98% pure, reagent grade)
Reagent-grade concentrated hydrochloric acid.
Reagent-grade methanol.
2.2. Reagent Solutions
1. Admicelle formation solution: Dissolve 0.3200 g SDS in 490 mL bidistilled water, then
adjust at pH 2.0 with hydrochloric acid and dilute to 500 mL in a volumetric flask.
2. Eluting solution: Dilute 325 µL HFBA to 25 mL with methanol in a volumetric flask.
3. Alumina surface-regenerating solutions: methanol and bidistilled water adjusted at pH
2.0 with hydrochloric acid.
2.3. Stock Standard Solutions
1. Stock standard 200-mg/L solutions of the following reagent-grade herbicides: DQ, MQ,
FQ, PQ, and CQ. Prepare individual stock solutions in bidistilled water and keep them in
polyethylene containers at 4ºC under light protection conditions.
2. Internal standard solution: Prepare a stock 200-mg/L ethyl viologen dibromide solution
in bidistilled water and store it in a polyethylene container at 4°C under light protection
conditions.
Analysis of Quaternary Ammonium Herbicides
407
Fig. 1. On-line setup coupling admicelle-based SPE to LC.
2.4. Mobile Phase
1. Solvent A: Add 250 mL bidistilled water to 750 mL acetonitrile.
2. Solvent B: Add 3.25 mL HFBA to 800 mL bidistilled water and dilute to 1 L in a volumetric flask.
2.5. Sampling Equipment
1. Amber polyvinylchloride 0.1- to 1-L high-density or silanized glass bottles. If amber
bottles are not available, protect samples from light.
2. Nylon 0.45-µm pore size, 47-mm diameter membrane filters.
2.6. On-Line Extraction System
The on-line setup coupling the admicelles-based solid-phase extraction (SPE) to
LC can be easily performed in any laboratory and consists of the following elements:
a speed-variable peristaltic pump, silicon rubber pumping tubes (1.14-mm id, 2.82mm od), an injection valve with a 200-µL sample loop, a Teflon precolumn (35 mm
long, 0.4-mm id) packed with 80 mg γ-alumina (155 m2/g surface area; 8.5 point of
zero charge [pcz]; 50- to 200-µm particle diameter range; 100-µm mean value; 58-Å
mean pore size; 3.97 g/cm3 density) and with cotton placed on either end to support
the alumina and a six-port switching valve with a 200-µL sample loop. These
elements are assembled according to the configuration shown in Fig. 1 using
polytetrafluoroethylene tubes (0.8-mm id).
408
Pérez-Bendito, Rubio, and Merino
2.7. LC–MS Equipment
An LC/ESI trap or quadrupole MS system (e.g., Agilent Technologies 1100 series,
Palo Alto, CA, or equivalent) coupled on-line with the extraction system above described. The analytical column recommended is a 25-cm C8 column with 4.1-mm id
and 5-µm particle diameter.
3. Methods
The methods described below outline (1) the way in which the sample must be
collected and preserved, (2) the on-line extraction of quats from water samples by
admicelles-based SPE, (3) the quantitation of analytes by LC–MS, and (4) their identification from tandem mass spectrometry (MS/MS) spectra.
3.1. Sample Collection and Preservation
1. Collect grab samples in either amber polyvinylchloride high-density or silanized glass
bottles. The analytes are light sensitive, particularly diquat.
2. Filter samples through 0.45-µm filters to remove suspended solids.
3. Preserve samples by storage at 4°C and addition of hydrochloric acid to pH 2.0.
4. Analyze samples within 7 days of collection.
3.2. On-Line Admicelle-Based Extraction (see Note 1)
The general scheme for the on-line preconcentration of quats onto SDS admicelles,
their elution, and regeneration of the sorbent is described in Subheadings 3.2.1.–3.2.5.
This includes (1) the formation of SDS admicelles onto the alumina surface, (2) the
sample preparation, (3) the percolation of the sample through the sorbent, (4) the elution of quats and their injection into the chromatographic system, and (5) the regeneration of the sorbent (see Note 2).
3.2.1. Formation of SDS Admicelles Onto the Alumina Surface (see Note 3)
The amount of SDS that must be passed through the mineral oxide to obtain maximum adsorbed surfactant (i.e., 176 mg SDS/g alumina) should be at least 200 mg
SDS/g alumina to consider the losses of surfactant caused by the admicelles:aqueous
surfactant monomers equilibrium.
1. Set the injector and switching valves in position 2 (Fig. 1)
2. Form admicelles by passing 25 mL admicelles formation solution (Subheading 2.2.1.)
through the precolumn at a flow rate of 2.5 mL/min.
3.2.2. Sample Preparation
The sample volume to be analyzed for quats must be less than 75 mL, which is the
breakthrough volume for the most polar quats (CQ and MQ) (see Note 4).
1. Add ethyl viologen (final concentration 1 µg/L) to 50 mL of the sample acidified with
hydrochloric acid (pH 2.0) using the internal standard solution (Subheading 2.3.2.).
2. Add the appropriate amount of SDS to give a concentration of 460 mg/L (see Note 5).
3.2.3. Percolation of Samples Through Admicelles
1. Pass the 50-mL water samples containing the analytes, the internal standard, and SDS at
pH 2.0 through the precolumn at a flow rate of 2.5 mL/min with the injector and switching valves set at position 2.
Analysis of Quaternary Ammonium Herbicides
409
2. Meanwhile, load the 200-µL sample loop of the injector with the eluting solution (Subheading 2.2.2.) and equilibrate the analytical column with the mobile phase (15% of
solvent A and 85% of solvent B, Subheading 2.4.).
3.2.4. Elution of Quats and Injection in the Chromatographic System
1. Switch the injection valve to position 2 and inject 200 µL of the eluting solution (Subheading 2.2.2.) (see Note 6)
2. Conduct the eluted analytes to the 200-µL sample loop of the six-port switching valve by
distilled water using a flow rate of 2.5 mL/min for 15 s (see Note 7)
3. Set the switching valve at position 1 to inject the quats in the chromatographic system and
simultaneously start the mobile phase gradient.
4. Return the switching valve to position 2 within 0.5–1 min to ensure the complete introduction of quats into the chromatographic system.
3.2.5. Regeneration of the Sorbent
1. Set the injection valve at position 1.
2. Regenerate the alumina surface into the precolumn by successively passing 1 mL of
MeOH, which disrupts the admicelles and removes the surfactant, and 5 mL of 0.01 M
HCl to recover the initial charge density on the alumina surface (see Note 8).
3. For initiation of a new run, proceed according to Subheading 3.2.1.
3.3. LS–MS Quantification
The steps described in Subheadings 3.3.1.–3.3.3. outline the procedure for the separation of quats by LC on a C8 reversed-phase column using HFBA as an ion pair
reagent and their quantification by MS (see Note 9).
3.3.1. Operating Conditions for Analysis of Quats
1. Establish the following elution gradient program for the chromatographic separation of
quats and methyl viologen: 0–20 min (linear gradient from 15 to 35% of solvent A, see
Subheading 2.4.1.); 20–25 min (linear gradient to 100% of solvent A); 25–32 min
(isocratic conditions with 100% of solvent A). The flow rate is 0.6 mL/min.
2. Program the diver valve to send the mobile phase to waste in the first 12 min of the
initiation of the elution gradient program to remove the most polar matrix compounds,
which can dirty the ionization source. After that, send the eluted components to the ESI
source.
3. Set the parameters of the MS/ESI specified in Table 1.
4. Acquire full-scan spectra of quats and the internal standard in the range 105–255 m/z,
with the target mass fixed to the following m/z values: 114 for MQ, 122 and 124 for CQ,
183 and 184 for DQ, 185 and 186 for PQ, 249 for FQ, and 212 and 213 for ethyl viologen.
5. Obtain smooth chromatograms by using the Gauss function (5-point width, 1 cycles).
3.3.2. Calibration
1. To closely match calibration standards to samples, process standards using the whole
procedure, that is, with the same experimental conditions as selected for the analysis of
unknown water samples (see Note 10). Working in this way, it is not necessary to know
the recovery of the extraction process for each analyte.
2. Prepare 50-mL calibration solutions containing between 3 and 400 ng of each quat, 1 µg/L
ethyl viologen, and 460 mg/L SDS; adjust with hydrochloric acid to pH 2.0 and make up
to volume.
410
Pérez-Bendito, Rubio, and Merino
Table 1
ESI Parameters Set for the Analysis of Quats
ESI(+) quats
Parameter
CQ
Capillary voltage (kV)
Capillary exit voltage (V)
Skimmer (V)
Trap drive
Source temperature (ºC)
Drying gas (L/min)
Nebulizer gas (psi)
Maximal accumulation time (ms)
–1.0
50
10
35
MQ
–1.0
50
10
35
DQ
PQ
–3.5
–3.5
30
30
20
20
40
40
350
10
80
IS
FQ
–3.0
40
30
35
–1.0
40
20
40
100
ISTD, internal standard.
3. Analyze a minimum of five calibration standards utilizing the LC–MS conditions specified in Subheading 3.3.1.
4. From the full-scan mass spectra of quats and methyl viologen (m/z scan range 105–255),
obtain the extracted ion chromatograms at the m/z values specified in Subheading 3.3.1.
for each herbicide and the internal standard (Fig. 2). Construct calibration curves from
the quats/internal standard ratio of peak areas of the extracted ion chromatograms. The
correlation coefficients r2 obtained are higher than 0.994 for all the quats (see Note 11).
3.3.3. Method Performance
1. The practical detection limits are estimated from independent complete determinations of
analyte concentrations in a typical matrix low-level material (22). They are calculated by
using a signal-to-noise ratio of 3 (the ratio between the quat peak area/internal standard
peak area and the peak area of noise). The detection limits calculated from six determinations ranged between 20 and 30 ng/L for CQ, MQ, PQ, and DQ, and it was about 10 ng/L
for FQ. These values were similar in distilled, tap, and mineral water.
2. Single-laboratory precision and accuracy results at several concentration levels in tap and
mineral water using the whole procedure are presented in Table 2.
3. The absence of interferences from matrix components that could elute with quats causing
ion suppression or space-charge effects on the ion trap was checked by comparison of the
calibration curves obtained from standards and those obtained from tap and mineral water
samples fortified with known amounts of quats. Because the analytical characteristics of
both types of calibration curves were similar, ordinary calibration is recommended for
analysis of quats in drinking water. Application of the method to other types of environmental water requires the assessment of the effect of matrix components (see Note 12).
4. Anionic and nonionic surfactant concentrations up to about 500 mg/L, which is the maximum level generally found in sewage effluents (23), do not interfere. Sodium chloride
concentrations below 0.04 M do not affect the adsorption of quats. Higher electrolyte
concentrations, however, decrease their recoveries. Thus, recoveries decrease about 75%
for CQ and MQ, 70% for DQ and PQ, and 55% for FQ in the presence of 0.2 M NaCl.
Analysis of Quaternary Ammonium Herbicides
411
Fig. 2. LC–MS extracted ion chromatograms obtained from a fortified tap water sample
containing 0.6 µg/L of each quat and has been treated using the whole procedure.
3.4. MS/ESI Identification of Quats
The steps that can be utilized for the identification of quats in water samples, on the
basis of the comparison of their retention time and MS/MS spectra with those obtained
from standard solutions, are described below (see Note 13).
1. Set in the ion trap the MS2 fragmentation mode and fix the related instrumental parameters to the following values: 27% of ion parent cutoff mass; 40-ms collision-induced
time; 4-m/z unit isolation width. The resonance excitation value used for each quat is
shown in Table 3.
2. Isolate the precursor ion specified for each quat in Table 3.
3. For quats in sampling matching the retention time of standards identify them on the basis
of the MS/MS spectra specified in Table 3.
4. Notes
1. The isotherm for the adsorption of SDS onto the positively charged alumina surface at pH
2.0 (Fig. 3) shows three regions available for the SPE of organic compounds: the
hemimicellar, hemimicellar/admicellar, and admicellar regions. The last one is recommended for adsolubilization of ionic organic compounds because their retention is favored owing to the formation of analyte:surfactant ion pairs. The quats PQ and DQ, which
have two quaternary nitrogens in their molecular structure, form with SDS ion pairs of
stoichiometry 1:2, whereas CQ, MQ, and FQ yield 1:1 quat:SDS ion pairs.
412
Table 2
Mean Recovery (%) and (Relative Standard Deviation [%]) of Quats in Fortified (N = 5) Drinking Water Samples (Analyzed
by On-Line Admicelle-Based SPE–LC–MS)
Fortified tap water (mg/L)
412
0.1
0.6
1.8
0.1
0.6
1.8
90 (11)
99 (13)
107 (8)
96 (10)
104 (9)
98 (10)
100 (8)
102 (8)
93 (9)
97 (7)
97 (6)
98 (5)
98 (6)
103 (4)
101 (3)
90 (12)
104 (11)
108 (9)
100 (7)
103 (10)
101 (9)
96 (9)
104 (7)
101 (8)
97 (8)
98 (6)
97 (7)
99 (5)
104 (6)
100 (4)
Pérez-Bendito, Rubio, and Merino
CQ
MQ
DQ
PQ
FQ
Fortified mineral water (mg/L)
Analysis of Quaternary Ammonium Herbicides
413
Table 3
Chemical Structure of Quats, Precursor Ions, and Excitations Resonance Values
Selected for Fragmentation and Relative Abundance and Structure of the Product Ions
Generated Under MS/MS/ESI(+) Analysis
414
Pérez-Bendito, Rubio, and Merino
2. The SPE methods developed for quats have been revised by Picó et al. (24). They are
based on cation exchange resins, silica sorbents, and apolar phases. Ion pair formation
using apolar SPE is the preferred method for isolating quats, and it has been proposed by
the Environmental Protection Agency as the reference method for DQ and PQ determination (25). However, some serious problems still remain (e.g., accuracy and precision are
very poor, and the methods are often too time consuming and tedious) that make it difficult to optimize the methods for monitoring a large number of samples (24). On the other
hand, methods for the determination of the most recently commercialized quats (FQ, MQ,
CQ) have been hardly developed.
3. According to the adsorption isotherm of SDS on alumina at pH 2.0 (Fig. 3), the amount of
surfactant adsorbed in the admicellar region is constant, with a rough value of 176 mg
SDS/g alumina. In this region, the SDS admicelles are in equilibrium with monomers of
surfactant in the aqueous phase at concentrations in the range 300–1417 mg/L.
4. The breakthrough volume increases to 100 mL for DQ and PQ and 125 mL for FQ. When
possible, it is better to handle a sample volume lower than the lowest breakthrough volume for more reproducible results. The preconcentration factor achieved for 50 mL of
sample using the LC/SPE–MS approach described here is about 250.
5. The addition of surfactant to samples is essential to ensure that the concentration of
admicelles in the mineral oxide remains constant during percolation of the sample because
it can be inferred from data of the SDS adsorption isotherm (Fig. 3), when admicelles are
used in on-line SPE applications, that the surfactant in the admicellar phase will continuously partition to the aqueous phase during percolation of the sample. As a result, the
concentration of admicelles will progressively decrease during operation, and the partition constant for analytes and therefore their retention will change. The concentration of
surfactant in the sample must be enough to replenish the losses of SDS caused by the
admicelles:aqueous monomers equilibrium and below the critical micellar concentration
of SDS at pH 2.0 (1417 mg/L) to avoid the partition of quats between aqueous micelles
and admicelles.
6. The eluting solution must cause desorption of analytes from the admicelle and be compatible with the mobile phase (acetonitrile and the ion pair reagent HBFA). Organic solvents
such as acetonitrile and methanol caused disruption of the admicelles and therefore elution of analytes. However, the eluted SDS–quats ion pairs are only partially substituted
by the HFBA–quats ion pairs through the chromatographic process. As a result, the chromatogram shows peaks corresponding to both types of ion pairs. It is therefore necessary
to add HFBA to the elution solvent at concentrations of about 0.1 M to produce complete
destruction of the SDS–quats ion pairs and as a result quantitative recovery of analytes.
The use of only aqueous HFBA does not achieve complete elution of quats. Sodium hydroxide, which also causes disruption of SDS admicelles by desorption of the surfactant
(8.5 pcz of the alumina), is not a good eluent for quats because low recoveries are obtained for the most apolar analytes probably because of their high retention on the negatively charged surface of the alumina.
7. This time must be calculated for each on-line extraction system because it depends on the
length of the tube connecting the precolumn and the switching valve.
8. The extraction precolumn works within a run for at least 20 cycles without deterioration.
However, progressive loss of efficiency has been observed for runs between days. Therefore, it is advisable to substitute the alumina daily.
9. LC procedures for analyzing ammonium quaternary herbicides in various samples after
SPE commonly use C18 reversed-phase columns and ion-pairing reagents in the mobile
Analysis of Quaternary Ammonium Herbicides
415
Fig. 3. Experimental adsorption isotherm for SDS on alumina at pH 2.0.
phase, such as heptanesulfonate (26,27), octanesulfonate (28), and orthophosphate (29).
Polymeric packings such as PS-DVD are recommended by the Environmental Protection
Agency to avoid the free silanol group effect (30–32). Coupling ion pair chromatography
with MS is not a good approach because of the high concentration of nonvolatile conventional ion pair reagents in the mobile phase. Systems containing only volatile buffers
such as HFBA (33) must be used. The utilization of ammonium acetate is not recommended because of the formation of quats–acetate adducts (34,35).
10. With on-line systems, it is not advisable to carry out quantitative analysis by comparison
with direct injections (36). First, the volume of many injection loops is specified to an
average accuracy of 20%, and calibration of a loop is a rather delicate and time-consuming operation. This does not have to be considered with off-line procedures because the
same loop is used for both analysis of unknown extracts and construction of calibration
curves. Second, slight but imperceptible band broadening may occur.
11. No gains in sensitivity are achieved by reducing the m/z scan range to 10 (termed selected
ion monitoring [SIM] mode in the operation of the Agilent system), which is logical
considering how an ion trap works (37). Thus, mass analysis in an ion trap consists of two
steps: (1) accumulation of ions in the trap and (2) production of a spectrum by resonantly
ejecting the ions from the trap to detector. Reducing the acquisition range only shortens
one part of the scan program (e.g., the time spent to production of the spectrum). As a
416
Pérez-Bendito, Rubio, and Merino
result, the number of microscans that can be acquired is increased, and the ion current
observed for SIM would be greater. However, only slight gains in sensitivity are achieved
(about two to three times). Although this modest gain in sensitivity may be beneficial in
some cases, the additional information that would have been provided by a full scan is
typically more significant. The inherent high sensitivity of the ion trap allows full-scan
spectra to be obtained at lower levels than can be detected with SIM on conventional
quadrupolar instruments. If an ion trap is not available and quantification is carried out
with a quadrupole filter instrument, SIM greatly improves sensitivity vs full scan by continuously collecting current for a single mass.
12. Space charge, defined as the electrostatic forces that exist between ions that are held in
closely to each other, can degrade severely the performance of the ion trap as a mass
spectrometer. The effects of space charge are observed commonly as losses in mass resolution or mass shifts. Therefore, it is very important to avoid overfilling the trap with
ions. However, the experts all agree that overfilling the trap is unlikely with commercial
instruments because an automatic gain control test scans to determine the total ion current
and adjusts accordingly the gate time for admitting ions into the trap. In real samples,
coelution of ions from components of the matrix can decrease the sensitivity for the target
ion because the trap is partially filled with other ions, but this possible interference can be
detected by comparison of the results obtained from calibration using a fortified sample
with known amounts of quats and using external standards.
13. Identification of quats in samples has been undertaken using thermospray (38), fast atom
bombardment (39), and atmospheric pressure ionization interfaces (40–42), typically in
combination with separation by either LC (38,40,41) or capillary electrophoresis (42,43).
Reported product ions by the different MS/MS techniques used have been similar. Some
detailed MSn studies on ion trap instruments have allowed the examination of the fragmentation pathways and the identification of a number of transitions that are highly specific to each quat (44). Assignation of structures to the product ions in Table 3 is based on
these previous studies.
Acknowledgment
We gratefully acknowledge financial support from the Spanish CICyT (project
BQU 2002-01017).
References
1. Dobias, B. (ed.). (1993), Coagulation and Flocculation. Surfactant Sciences, Series 477.
Marcel Dekker, New York.
2. Bohmer, M. R. and Koopal, L. K. (1992) Adsorption of ionic surfactants on variablecharge surfaces. 1. Charge effects and structure of the adsorbed layer. Langmuir 8,
2649–2659.
3. Bohmer, M. R. and Koopal, L. K. (1992) Adsorption of ionic surfactants on variablecharge surfaces. 2. Molecular architecture and structure of the adsorbed layer. Langmuir
8, 2660–2665.
4. Koopal, L. K., Lee, E. M., and Bohmer, M. R. (1995) Adsorption of cationic and anionic
surfactants on charged metal oxide surfaces. J. Colloid Interface Sci. 170, 85–97.
5. Goloub, T. P., Koopal, L. K., Bijsterbosch, B. H., and Sidorova, M. P. (1996) Adsorption
of cationic surfactants on silica. Surface charge effects. Langmuir 12, 3188–3194.
6. Valsaraj, K. T. (1989) Partitioning of hydrophobic nonpolar volatile organics between the
aqueous and surfactant aggregate phase on alumina. Sep. Sci. Technol. 24, 1191–2005.
Analysis of Quaternary Ammonium Herbicides
417
7. Valsaraj, K. T. (1992) Adsorption of trace hydrophobic compounds from water on surfactant-coated alumina. Sep. Sci. Technol. 27, 1633–1642.
8. Harwell, J. H., Hoskins, J., Schechter, R. S., and Wade, W. H. (1985) Pseudophase separation model for surfactant adsorption: isomerically pure surfactants. Langmuir 1, 251–262.
9. Behrends, T. and Herrmann, R., (2000) Adsolubilization of anthracene on surfactant covered silica in dependence on pH: indications for different adsolubilization in admicelles
and hemimicelles. Colloids Surf. A 162, 15–23.
10. Bury, R., Favoriti, P., and Treiner, C. (1998) Specific interactions between salicylate derivatives and cetylpyridinium chloride both at the silica/water interface and in solution. A
calorimetric investigation. Colloids Surf. A 139, 99–107.
11. Pramauro, E. and Pelizzetti, E. (eds.). (1996) Surfactants in Analytical Chemistry, Applications of Organized Amphiphilic Media. Elsevier, New York.
12. Manzoori, J. L., Sorouraddin, M. H., and Schemirani, F. (1995) Chromium speciation by a
surfactant-coated alumina microcolumn using electrothermal atomic absorption spectrometry. Talanta 42, 1151–1155.
13. Hiraide, M. and Shibata, W. (1998) Collection of trace heavy metals on dithizone-impregnated admicelles for water analysis. Anal. Sci. 14, 1085–1088.
14. Manzoori, J. L., Sorouraddin, M. H., and Schabani, A. M. H. (1998) Determination of
mercury by cold vapor atomic absorption spectrometry after preconcentration with
dithizone immobilized on surfactant-coated alumina. J. Anal. At. Spectrom. 13, 305–308.
15. Manzoori, J. L., Sorouraddin, M. H., and Schabani, A. M. H. (1999) Atomic absorption
determination of cobalt after preconcentration by 1-(2-pyridylazo)-2-naphtol immobilized
on surfactant-coated alumina. Microchem. J. 63, 295–301.
16. Hiraide, M., Iwasawa, J., and Kawaguchi, H. (1997) Collection of trace heavy metals
complexed with ammonium pyrrolidinedithiocarbamate on surfactant-coated alumina sorbents. Talanta 44, 231–237.
17. Hiraide, M. and Hori, J. (1999) Enrichment of metal–APDC complexes on admicellecoated alumina for water analysis. Anal. Sci. 15, 1055–1058.
18. Rubio, S. and Pérez-Bendito, D. (2003) Supramolecular assemblies for extracting organic
compounds. Trends in Anal. Chem. 22, 470–485.
19. Saitoh, T., Nakayama, Y., and Hiraide, M., (2002) Concentration of chlorophenols in water with sodium dodecylsulfate-γ-alumina admicelles for high-performance liquid chromatographic analysis. J. Chromatogr. A 972, 205–309.
20. Merino, F., Rubio, S., and Pérez-Bendito, D. (2003) Solid-phase of amphiphiles based on
mixed hemimicelle/admicelle formation: application to the concentration of benzalkonium
surfactants in sewage and river water. Anal. Chem. 75, 6799–6806.
21. Merino, F., Rubio, S., and Pérez-Bendito, D. (2004) Evaluation and optimization of an online admicelle-based extraction–liquid chromatography approach for the analysis of ionic
organic compounds. Anal. Chem. 76, 3878–3886.
22. Thompson, M. and Ellison, S. L. R. (2002) Harmonised guidelines for single laboratory
validation of methods of analysis. Pure Appl. Chem. 74, 835–855.
23. Matthew, J. S. and Jones, M. N. (2000) The biodefradation of surfactants in the environment. Biochim. Biophys. Acta, 1508, 235–251.
24. Picó, Y., Font, G., Moltó, J. C., and Mañes, J. (2000) Solid-phase extraction of quaternary
ammonium herbicides. J. Chromatogr. A 885, 251–271.
25. Hodgeson, J. W., Bashe, W. J., and Eichelberger, J. W. (1997) Method 549.2 Determination of Diquat and Paraquat in Drinking Water by Liquid–Solid Extraction and High Performance Liquid Chromatography With UV Detection. Environmental Protection Agency,
Cincinnati, OH, p. 101.
418
Pérez-Bendito, Rubio, and Merino
26. Corasaniti, M. T., Strongoli, M. C., and Nisticò, G. (1990) Determination of paraquat in
rat brain using ion-pair solid-phase extraction and reversed-phase high-performance liquid chromatography with ultraviolet detection. J. Chromatogr. B 527, 189–195.
27. Corasaniti, M. T. and Nisticò, G. (1993) Determination of paraquat in rat brain by highperformance liquid chromatography. J. Chromatogr. A 643, 419–425.
28. Needham, L., Paschal, D., Rollen, Z. J., Liddle, J., and Bayse, D. (1979) Determination of
paraquat in marihuana by reversed-phase paired-ion high performance liquid chromatography. J. Chromatogr. Sci. 17, 87–90.
29. Ahmad, I. (1983) On-line trace enrichment of difenzoquat in water and its determination
by HPLC. J. Environ. Sci. Health, 18, 207–219.
30. Hodgeson, J. W. and Bashe, W. J. (1990) Method 549, in Determination of Diquat and
Paraquat in Drinking Water by Liquid–Solid Extraction and High Performance Liquid Chromatography With UV detection. Environmental Protection Agency, Cincinnati, OH, p 101.
31. Hodgeson, J. W., Bashe, W. J., and Eichelberger, J. W. (1992) Method 549.1, in Determination of Diquat and Paraquat in Drinking Water by Liquid–Solid Extraction and High
Performance Liquid Chromatography With UV detection. Environmental Protection
Agency, Cincinnati, OH, p. 119.
32. 40 CFR Part 141. (1998) National Primary Drinking Water Regulation: Analytical Methods for Certain Pesticides and Microbial Contaminants, Proposed Rule. Environmental
Protection Agency, Cincinnati, OH.
33. Marr, J. C. and King, J. B. (1997) A simple high performance liquid chromatography/
ionspray tandem mass spectrometry method for the direct determination of paraquat and
diquat in water. Rapid Commun. Mass Spectrom. 11, 479–483.
34. Catherine, S. E., Startin, J. R., Goodall, D. M., and Keely, B. J. (2001) Formation of gasphase clusters monitored during electrospray mass spectrometry: a study of quaternary
ammonium pesticides. Rapid Commun. Mass Spectrom. 15, 1341–1345.
35. Taguchi, V. Y., Jenkins, S. W. D., Crozier, P. W., and Wang, D. T. (1998) Determination
of diquat and paraquat in water by liquid chromatography (electrospray ionization) mass
spectrometry. J. Am. Soc. Mass Spectrom. 9, 830–839.
36. Hennion, M. C. (1999) Solid-phase extraction:method development, sorbents, and coupling with liquid chromatography. J. Chromatogr. A 856, 3–54.
37. Yates, N. A., Booth, M. M.; Stepheson, J. L., and Yost, R. A. (1995) Practical Ion Trap
Technology: GC/MS and GC/MS/MS, in Practical Aspects of Ion Trap Mass Spectrometry (Raymon, E. M. and Todd, J. F. J., eds.). CRC Press, New York, 1995, Chapter 4, pp.
121–186.
38. Barcelo, D., Durant, G., and Vreeken, R. J. (1993) Determination of quaternary amine
pecticides by thermospray mass spectrometry. J. Chromatogr. A 647, 271–277.
39. Todeur, Y., Sovocool, G. W., Mitchum, R. K., Niederhut, W. J., and Donnelly, J. R. (1987)
Use of FAB MS/MS for analysis of quarternary amine pesticide standards. Biomed.
Environ. Mass Spectrom. 14, 733–736.
40. Evans, C. S., Startin, J. R., Goodall, D. M., and Keely, B. J. (2000). Optimisation of ion
trap parameters for the quantification of chlormequat by liquid chromatography/mass spectrometry and the application in the analysis of pear extract. Rapid Commun. Mass
Spectrom. 14, 112–117.
41. Castro, R., Moyano, E., and Galceran, M. T. (1999) Ion-pair liquid chromatography–atmospheric pressure ionization mass spectrometry for the determination of quaternary ammonium herbicides. J. Chromatogr. A 830, 145–154.
Analysis of Quaternary Ammonium Herbicides
419
42. Moyano, E., Games, D. E., and Galceran, M. T. (1996) Determination of quaternary ammonium herbicides by capillary electrophoresis/mass spectrometry. Rapid Commun. Mass
Spectrom. 10, 1379–1385.
43. Wycherley, D., Rose, M. E., Giles, K., Hutton, T. M., and Rimmer, D. A. (1996) Capillary
electrophoresis with detection by inverse UV spectroscopy and electrospray mass spectrometry for the examination of quaternary ammonium herbicides. J. Chromatogr. A 734,
339–349.
44. Catherine, S. E., Startin, J. R., Goodall, D. M., and Keely, B. J. (2001) Tandem mass
spectrometric analysis of quaternary ammonium pesticides. Rapid Commun. Mass
Spectrom. 15, 699–707.
Molecular Imprinted Solid-Phase Extraction
421
31
Molecular Imprinted Solid-Phase Extraction for Cleanup
of Chlorinated Phenoxyacids From Aqueous Samples
Claudio Baggiani and Cristina Giovannoli
Summary
Solid-phase extraction (SPE) represents a suitable way to clean up and preconcentrate
samples containing traces of chlorinated phenoxyacids. High selectivity levels may be
obtained using columns packed with materials based on well-defined molecular recognition mechanisms, such as immunoaffinity columns. SPE procedures involving molecular imprinted polymers (MISPE, molecular imprinted solid-phase extraction) have been
proposed as a valid substitute for immunoaffinity procedures because of their simplicity
of preparation and high stability to extreme chemical conditions. Here, we describe the
preparation and the use of a polymer obtained by imprinting with the herbicide 2,4,5trichlorophenoxyacetic acid as a molecular imprinted SPE sorbent. The polymer will be
useful for extracting and concentrating selectively several strictly related phenoxyacids
(2,4,5-trichlorophenoxyacetic acid; 2,4-dichlorophenoxyacetic acid; (R,S)-2-(2,4,5trichlorophenoxy)-propionic acid; (R,S)-2-(2,4-dichlorophenoxy)-propionic acid; 2-methyl-4-chlorophenoxyacetic acid; and (R,S)-2-(2-methyl-4-chlorophenoxy)-propionic
acid) from water samples before performing the analysis by capillary electrophoresis or
high-performance liquid chromatography.
Key Words: Cleanup; 2,4-D; dichlorprop; fenoprop; halogenated phenoxyacids;
herbicides; MCPA; mecoprop; molecular imprinting; molecular recognition;
preconcentration; solid-phase extraction; 2,4,5-T.
1. Introduction
Legislation poses severe limits on the presence of chlorinated phenoxyacids in waters because of their high toxicity for mammals and aquatic organisms and long-term
persistence in the environment. Thus, these pesticides are suitable subjects of trace
analysis. Because of their insufficient sensitivity, the detection and quantification of
these substances at trace levels cannot be performed directly using traditional analytical techniques, but it requires one or more preconcentration steps.
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
421
422
Baggiani and Giovannoli
Solid-phase extraction (SPE) represents a suitable way to clean up and
preconcentrate samples containing traces of chlorinated phenoxyacids. This technique
is more rapid, simple, economical, and environment friendly than traditional liquid–
liquid extraction. The main drawback associated with SPE columns packed with ordinary stationary phases is the low selectivity of the retention mechanism. Also, with the
desired analyte(s), many interfering substances of similar hydrophobicity/hydrophilicity are retained and concentrated because of the very limited selectivity of the partition equilibriums involved (1–4).
Selectivity may be obtained using columns packed with materials based on welldefined molecular recognition mechanisms, such as immunoaffinity columns. These
kinds of SPE columns are affected by problems that limit more general use. High
production costs for specific antibodies from polyclonal or monoclonal antisera and
the poor stability of the antibody-binding sites in the organic solvents make largescale use of these sorbents impracticable (5–7).
Of the many ways to make synthetic hosts able to imitate natural antibodies, one of
the most interesting involves molecular imprinting. In this technique, functional monomers are assembled around a template (imprint) molecule by noncovalent interactions
and then linked together using a cross-linking agent. Template removal leaves cavities
within the molecularly imprinted polymer (MIP) that possess a shape and functional
group complementarity to the imprint molecule, allowing its tight and selective uptake
(8–10). SPE procedures involving molecular imprinted polymers (MISPE, molecular
imprinted solid-phase extraction) have been proposed as a valid substitute for
immunoaffinity procedures because of their simplicity of preparation and high stability to extreme chemical conditions (11–14).
Here, we describe the use of a polymer obtained by imprinting with the herbicide
2,4,5-trichlorophenoxyacetic acid (2,4,5-T) as a MISPE sorbent. This polymer is used
to extract and concentrate several strictly related phenoxyacids from water samples
before analysis by capillary electrophoresis or high-performance liquid chromatography (HPLC).
2. Materials
2.1. Halogenated Herbicides
1. Analytical-grade 2,4,5-T. Caution: Do not use technical 2,4,5-T because of the risk of
contamination by chlorinated dioxins.
2. Analytical-grade 2,4-dichlorophenoxyacetic acid (2,4-D). Caution: Do not use technical
2,4-D because of the risk of contamination by chlorinated dioxins.
3. Analytical-grade (R,S)-2-(2,4,5-trichlorophenoxy)-propionic acid (fenoprop).
4. Analytical-grade (R,S)-2-(2,4-dichlorophenoxy)-propionic acid (dichlorprop).
5. Analytical-grade 2-methyl-4-chlorophenoxyacetic acid (MCPA).
6. Analytical-grade (R,S)-2-(2-methyl-4-chlorophenoxy)-propionic acid (mecoprop).
7. Mother solutions for items 1–6: 2 mg/mL in acetonitrile; store at −20°C.
2.2. Polymerization Reagents
1. Synthesis-grade 4-vinylpyridine (4-VP). Caution: Toxic for ingestion; skin sensitizer, risk
of irreversible effects.
Molecular Imprinted Solid-Phase Extraction
423
2. Synthesis-grade ethylene dimethacrylate (EDMA).
3. Synthesis-grade 2,2′-azobis-(butyronitrile) (AIBN). Caution: The solid decomposes violently when heated; store at −20°C)
2.3. Solvents and Chemicals
1. Analytical-grade methanol. Caution: Toxic for inhalation, ingestion, and contact. Risk of
irreversible effects.
2. HPLC-gradient-grade acetonitrile. Caution: Highly flammable. Toxic for inhalation, ingestion, and contact.
3. Analytical-grade glacial acetic acid. Caution: Risk of severe burns.
4. Analytical-grade formic acid. Caution: Risk of severe burns.
5. Analytical-grade sodium phosphate monobasic dihydrate.
6. Analytical-grade sodium tetraborate decahydrate.
7. Ultrapure water.
8. α-Cyclodextrin.
9. β-Cyclodextrin.
10. γ-Cyclodextrin.
2.4. Laboratory Equipment
1.
2.
3.
4.
5.
6.
7.
8.
Ultrasound bath.
Mechanical mortar.
90- and 25-µm sieves.
Soxhlet apparatus for continuous extraction.
Empty SPE cartridges (glass or polypropylene).
Vacuum manifold for SPE.
Capillary electrophoresis apparatus with ultraviolet (UV) detector.
HPLC apparatus with binary pumps and UV detector.
3. Methods
The methods described below outline (1) the preparation of the 2,4,5-T-imprinted
polymer, (2) the preparation of the MISPE column, (3) the extraction of halogenated
phenoxyacids from aqueous samples, and (4) the determination of extracted analytes
by capillary electrophoresis and HPLC.
3.1. Preparation of the 2,4,5-T-Imprinted Polymer
This method describes the preparation of a 4-vinylpyridine-co-ethylene
dimethacrylate polymer by radical thermopolymerization in the presence of a template
molecule able to mimic the analytes. The use of a mimic is justified by the necessity to
imprint the polymer with a molecule not present in the analytical samples to avoid interferences in the subsequent analysis because of the slow release of residual template.
The molecular recognition properties of the 2,4,5-T-imprinted polymer are caused
by ionic and hydrophobic interactions between the molecules of template and the binding sites (see Fig. 1). To obtain strong hydrophobic interactions, it is necessary to use
a polar porogenic solvent during the polymerization process. Solvents frequently used
in molecular imprinting technology such as chloroform and acetonitrile are less efficient. In fact, polymers obtained with these solvents show poor binding capacity and
reduced selectivity (15).
424
Baggiani and Giovannoli
Fig. 1. Conceptual model of the molecular recognition properties of the 2,4,5-T-imprinted
polymer are caused by ionic and hydrophobic interactions between the molecules of the template and the binding site.
1. In a 10-mL wall test tube, dissolve under sonication 0.600 g 2,4,5-T (2.35 mmol) into
3.70 mL methanol–water (3:1 v/v) (see Note 1). Then, add 0.243 mL (2.35 mmol, molar
ratio template–functional monomer 1:1) 4-VP, 3.53 mL EDMA (15.7 mmol, molar ratio
functional monomer–cross-linker 1:8) (see Note 2) and 0.050 g AIBN (see Note 3).
2. Purge the test tube with analytical-grade nitrogen for almost 5 min (see Note 4), seal with
an airtight plug. and leave it to polymerize overnight at 65°C in a water bath (see Notes 5
and 6).
3. After complete polymerization of the mixture, open the plug (see Note 7) and grind the
pale blue-white monolith obtained (see Note 8) in a mechanical mortar (see Note 9).
4. Separate the grinded powder through a double sieve (90-µm upper screen, 25-µm lower
screen) to isolate a fraction suitable for SPE column packing.
5. Wet the fraction retained by the 25-µm screen with methanol and wash carefully with
abundant deionized water to eliminate the submicrometric dust that adheres to the polymer particles (see Note 10).
6. Wash the obtained particle fraction with acetic acid by overnight extraction in a Soxhlet
apparatus to eliminate the residual template (see Note 11). Dry the polymeric particles at
50°C overnight (see Note 12).
3.2. Preparation of the MISPE Column
This method describes the packing and the stabilization of SPE columns with the
imprinted polymer. The amount of polymer used is suitable for the extraction/cleanup
of aqueous samples not exceeding 100 mL. The stabilization of the columns is a necessary step to eliminate residual molecules of template that could interfere in the pesticide extraction and analysis (see also Note 13).
Molecular Imprinted Solid-Phase Extraction
425
Fig. 2. Structure of halogenophenoxyacid herbicides recognized by the 2,4,5-T-imprinted
polymer.
1. Mix 0.200 g dry polymer with 1 mL methanol in a test tube and sonicate until complete
homogeneity of the suspension is reached (see Note 14).
2. Transfer the suspension rapidly into an empty 5-mL SPE column provided with outlet frit
and stopcock to secure the packing (see Note 15).
3. Connect the column to a vacuum manifold and apply a gentle vacuum until the polymer is
completely packed (see Note 16). Then, apply an inlet frit, gently pushing it into the
column with a glass rod of proper dimension (see Note 17).
4. Wash the SPE column, adding sequentially 1 mL acetic acid, methanol, and water.
5. Check the presence of residual 2,4,5-T after washing with acetic acid (see Note 13; see
also Subheadings 3.4. and 3.5.).
6. Repeat the cycle if 2,4,5-T is present in the eluate.
3.3. Extraction of Halogenated Phenoxyacids From Aqueous Samples
This method describes the extraction of some halogenated phenoxyacids from aqueous samples. The polymer imprinted with 2,4,5-T shows selectivity toward a small
group of halogenated phenoxyacids, strictly resembling the template in their molecular structures (see Fig. 2): 2,4-D, fenoprop, dichlorprop, MCPA, and mecoprop. Other
halogenated phenoxyacids and related esters are not recognized (see Table 1). The
same happens for acidic pesticides characterized by molecular structures very different from the template.
The extraction protocol is based on three distinct steps (see Fig. 3): (1) column
loading, in which the analytes and other hydrophobic substances are retained and hydrophilic neutral substances and inorganic ions are eluted; (2) column washing, in
which the analytes are retained and other hydrophobic substances are eluted; (3) column elution, in which the analytes are recovered.
1. Filtrate about 5 mL aqueous sample on 0.22-µm polyethylene or Teflon membranes
mounted on cartridges (see Note 18). If the filtered sample is viscous, dilute 1:1 with
deionized water.
426
Table 1
Recoveries on MISPE Column Using 10 mL Deionized Water Containing 2 mg/mL of Analytes
Herbicides, recovery percentage for 20 mg in 10 mL deionized water
426
Washing, first milliliter
Washing, second milliliter
Washing, third milliliter
Elution, first milliliter
Elution, second milliliter
Elution, third milliliter
Recovery percentage
2,4,5-T
2,4-D
Fenoprop
Dichlorprop
MCPA
Mecoprop
Atrazine
Bentazone
n.d.
n.d.
n.d.
97.5 ± 4
6±2
n.d.
103.5 ± 6
n.d.
n.d.
n.d.
98.5 ± 3.5
n.d.
n.d.
98.5 ± 3.5
n.d.
n.d.
n.d.
96.5 ± 4
n.d.
n.d.
96.5 ± 4
n.d.
n.d.
n.d.
95 ± 7.5
n.d.
n.d.
95.0 ± 7.5
n.d.
n.d.
6.5 ± 2.5
87 ± 7
n.d.
n.d.
87.0 ± 7
n.d.
n.d.
10.5 ± 3.5
88.5 ± 8
n.d.
n.d.
88.5 ± 8
98.5 ± 3
n.d.
n.d.
n.d.
n.d.
n.d.
0
98 ± 2
n.d.
n.d.
n.d.
n.d.
n.d.
0
Baggiani and Giovannoli
Source: Data taken from ref. 16. The recovery was calculated excluding the herbicide found in methanol after column washing. n.d., not
detectable.
Molecular Imprinted Solid-Phase Extraction
427
Fig. 3. Scheme of a typical molecularly imprinted solid-phase extraction.
2. Adjust the pH to 3.0 with 0.1 N aqueous hydrogen chloride (see Note 19). Samples containing organic solvents typically need to be diluted with water. The actual concentration
of organic solvent that can be tolerated without affecting the column capacity must be
less than 10% (v/v).
3. Rinse the column with 3 mL deionized water, pH 3.0, applying a flow rate of 3–5 mL/
min.
4. Apply 1 mL sample (see Note 20) to the column with the vacuum turned off.
5. Aspirate the sample through the column at a flow rate of approx 1 mL/min or allow it to
flow by gravity (see Note 21).
6. Wash the column three times with 1 mL methanol at a flow rate of approx 1 mL/min (see
Note 22).
7. After the wash methanol has been passed through the column, dry the column under full
vacuum for 2–5 min.
8. Turn off the vacuum and wipe the tips of the manifold needles to remove any residual
wash solvent (see Note 23).
9. Insert collection tubes into the manifold rack.
10. Elute the column three times with 1 mL methanol–acetic acid or methanol–trifluoroacetic
acid 4:1 (v/v) (see Notes 22 and 24) at a flow rate of approx 1 mL/min and collect the
analytes (see Note 25).
11. Evaporate the eluate in a rotating evaporator or under a gentle stream of nitrogen.
12. Rinse the collection tubes three times under sonication with 0.200 mL of a solution suitable for the analytical detection (phosphate–borate buffer for capillary electrophoresis,
acetonitrile–water 2:3 v/v containing 25 mM formic acid for liquid chromatography) (see
Note 26).
13. Store the samples at −20°C.
3.4. Determination of Extracted Analytes by Capillary Electrophoresis
There is a large body of literature on the detection and quantification of halogenated phenoxyacids by capillary electrophoresis or liquid chromatography. The examples reported here (see Figs. 4 and 5) were chosen because of their simplicity. It
should be noted that the capillary electrophoresis method is not suitable for a mass
428
Baggiani and Giovannoli
Fig. 4. Capillary electrophoresis of a 5-mL tap water sample spiked with a mixture containing 2 µg of a, dichlorprop; b, fenoprop; c, mecoprop; d, 2,4-D; and e, 2,4,5-T.
spectroscopy detector because of the presence of cyclodextrins in the running buffer;
the liquid chromatography method can be easily adapted.
3.4.1. Capillary Electrophoresis
1. Prepare standard solutions of halogenated phenoxyacids in concentrations ranging from
0.25 to 25.0 mg/L by dilution of mother solutions with the running buffer (vide infra).
2. Filter 0.5 mL of each standard through a 0.22-µm polyethylene filter in suitable polypropylene autosampler vials (see Note 27).
3. Before each run (see Note 28), rinse the capillary (fused silica 50-µm id, 50 cm total
length) with 0.1M sodium hydroxide for 90 s, with ultrapure water for 120 s, and with run
buffer for 120 s.
Running conditions: running buffer is phosphate–borate buffer (50 mM sodium phosphate monobasic, pH corrected to 7.5 with sodium tetraborate, containing 2.75 mM α-, β, and γ-cyclodextrin); capillary thermostated at 25°C; hydrodynamic injection mode (0.07
MPa/s) for 3 s; cathodic run with applied voltage to 20 kV (current of about 60 µA); 200nm UV detection at the cathodic end of the capillary.
4. For each standard and sample, perform a minimum of three runs. For each sample, integrate the peaks and calculate the mean area (see Note 29).
5. Build a calibration line by plotting the mean peak areas vs the concentrations of the standard solutions.
Molecular Imprinted Solid-Phase Extraction
429
Fig. 5. Liquid chromatography of a tap water sample extracted on the MISPE column. 5 mL
spiked with a mixture containing 2 µg of 2,4-D (1), MCPA (2), dichlorprop (3) and mecoprop (4).
6. The concentration of the phenoxyacids in the samples is given by the formula d × (V1/V2)
× (A × b0)/b1, where d is the dilution factor of the sample (Subheading 3.3., steps 1 and
2); V1 is the volume of the sample introduced in the MISPE column (Subheading 3.3.,
step 4); V3 the overall volume of the solution used to recover the eluate after the evaporation step (Subheading 3.3., step 12); A is the mean peak area; and b0 and b1 are the
intercept and the slope of the calibration line, respectively.
7. Use common statistical tests to verify method accuracy and reproducibility.
3.4.2. Liquid Chromatography
1. Prepare standard solutions of halogenated phenoxyacids in concentrations ranging from
0.20 to 20.0 mg/L by dilution of mother solutions with eluent A (vide infra).
2. Filter 0.5 mL of each standard through a 0.22-µm polyethylene filter in suitable polypropylene autosampler vials (see Note 27).
3. Before each run (see Note 30), equilibrate the column with eluent A following the absorbance at 230 nm until it falls below 0.001 UAFS and is stable for more than five column
volumes.
Elution conditions: column thermostated at 25°C; 5-µL loop injection; linear gradient
from 60% acetonitrile–40% water (containing 25 mM formic acid, eluent A) to 80%
acetonitrile–20% water (containing 25 mM formic acid, eluent B) in 30 min; mobile phase
flow rate 1 mL/min; 230-nm UV detection.
4. For each standard and sample, perform a minimum of three runs. For each sample, integrate the peaks and calculate the mean area.
430
Baggiani and Giovannoli
5. Build a calibration line by plotting the mean peak areas vs the concentrations of the standard solutions.
6. The concentration of the phenoxyacids in the samples is given by the formula d × (V1/V2)
× (A × b0)/b1, where d is the dilution factor of the sample (Subheading 3.3., steps 1 and
2), V1 is the volume of the sample introduced in the MISPE column (Subheading 3.3.,
step 4); V3 is the overall volume of the solution used to recover the eluate after the evaporation step (Subheading 3.3., step 12); A is the mean peak area; and b0 and b1 are the
intercept and the slope of the calibration line, respectively.
7. Use common statistical tests to verify method accuracy and reproducibility.
4. Notes
1. 2,4,5-T cannot be appreciably dissolved in deionized water. To obtain a solution rapidly,
dissolve 2,4,5-T in methanol and then slowly add the proper amount of water under continuous stirring or sonication. Direct dissolution of 2,4,5-T in the hydroalcoholic mixture
is less efficient.
2. Commercial 4-VP and EDMA are stabilized with alkylphenols to suppress polymerization. They must be purified by distillation under reduced pressure immediately before
use. Liquid–liquid extraction with diluted sodium hydroxide solutions is not convenient
with the water-soluble 4-VP and less efficient with EDMA.
3. Other suitable radical initiators are 2,2′-azobis-(2,2,3-trimethylbutyronitrile) and 2,2′azobis-(3-methoxy-2,2,3-trimethylbutyronitrile). When these initiators are used instead of
AIBN, the polymerization temperature must be decreased to 50°C and 30°C, respectively.
4. Molecular oxygen is a powerful inhibitor of radical polymerization. Attention should be
paid to maintain an inert atmosphere during the polymerization stage. Nitrogen can be
conveniently substituted with argon or helium.
5. Imprinted polymers can be obtained by photoinduced radical polymerization using UV
light sources (high- or medium-pressure mercury vapor lamps with 366-nm line of emission). The polymerization process is noticeably faster, and useful polymers are obtained
within 1–6 h working at room temperature or in an ice bath. It should be taken into account that materials prepared by photopolymerization show enhanced selectivity but reduced sample capacity with respect to materials prepared by thermopolymerization.
6. Radical polymerization is an exothermic process. To avoid dangerous superheating of the
polymerization mixture (with risk of an explosive runaway), do not try to prepare very
large quantities of polymer (exceeding 250 mL of prepolymerization mixture) at once.
7. Very frequently, the polymeric monolith cannot be easily taken out of the test tube. In this
case, smash the test tube with a steel spatula. The use of hammers or related devices
should be avoided because of the risk of loss of polymer and contamination by glass
fragments.
8. The polymer should be a white to very pale blue homogeneous monolith, sometimes with
cracks. Excessive translucency, bubbles, or marked discontinuities in the polymeric texture indicate incomplete polymerization. Yellow-to-reddish appearance indicates 4-VP
oxidation. Such polymers should be discarded.
9. The grinding/sieving step produces many very fine, submicrometric particles. This dust
is potentially dangerous for the lungs. Undertake the operation under a hood or wear a
suitable antidust mask. A porcelain mortar can also be used for manually grinding the
polymer. However, this option is suitable only with a limited amount of material and
takes a longer time.
Molecular Imprinted Solid-Phase Extraction
431
10. Very fine, submicrometric powder could cause excessive high back pressures in the SPE
column during and after the packing procedure. Multiple washings are fundamental to
obtain dust-free polymeric particles.
11. Polymers for SPE applications require exhaustive Soxhlet extraction with the highly polar glacial acetic acid to obtain materials sufficiently free from residual template. Do not
use methanol or acetonitrile as an extracting solvent because the amount of residual template in the polymer makes this material suitable for column chromatography but not for SPE.
12. Imprinted polymers are very stable under ordinary laboratory conditions and are resistant
to acidic or basic conditions, organic solvents, high temperature (not exceeding 150°C),
and pressure. They can be stored dry at room temperature for an indefinite amount of time
without loss of binding properties. Avoid chemical oxidation.
13. Changing solvents from acetic acid to methanol and water causes cycles of polymer swelling/shrinking, with subsequent release of residual template molecules. We observed that
2,4,5-T-imprinted polymers are less prone to slow release of residual template than other
imprinted polymers.
14. The suspension should be very homogeneous without colored particles or visible aggregates. After transferring the suspension in the column, polymer particles remaining in the
test tube can be recovered by washing with some aliquots of methanol.
15. Glass SPE columns are expensive, but they can be accurately washed and recycled. Polyethylene SPE columns are very economical and commercially available in many formats
but are more easily contaminated by several chemicals.
16. Never let the packed layer of polymer dry. Control the vacuum aspiration, slowly sucking
the liquid layer of mobile phase. Close the stopcock immediately before the column runs
dry. Extractions of analytes performed on dry columns are less reproducible and recoveries are not quantitative. If the column goes dry, it should be discarded, recovering the
polymer eventually.
17. When pushing the inlet frit, do not press the polymer layer. A compressed layer offers
more flow resistance to the liquid samples, and it makes column elution more difficult
and, sometimes, very slow.
18. In most cases, particulates and other insoluble material can rapidly clog the column. The
use of filtration membranes is efficient for elimination of these materials. It should be
taken into the account that many biomacromolecules are too small to be retained by the
membrane and potentially may interfere with the SPE and successive detection of the
analytes. Avoid direct extraction of biological fluids, applying this protocol without a
proper sample pretreatment.
19. The extraction column works efficiently only when aqueous samples are acidified. Aqueous hydrogen chloride may be substituted by diluted nitric or phosphoric acid. Avoid
organic acids such as acetic, trifluoroacetic, or chloroacetic acid because they interfere
with the retention mechanism. If the sample is buffered, use more concentrated acid.
20. Sample volumes between 0.5 and 10 mL do not require modifications to the method.
Extraction of water samples with a volume up to 10 mL requires optimization of the
washing and extraction volumes.
21. A slow rate of sample application is generally preferable because the kinetics of sorbentanalyte interactions is highly variable and strongly influenced by the composition of the
sample.
22. Three small aliquots of solvent ensure improved analyte recovery rather than a single,
larger volume aliquot.
432
Baggiani and Giovannoli
23. Drying removes all traces of residual sample and washes solvent from the polymer. This
produces a more concentrated final extract with a constant volume and composition and
ensures better reproducibility and higher recoveries. Avoid overdrying the column because analyte recovery may decrease with excessive vacuum or drying times above 5
min. Note that dry columns look distinctly different from moist ones. Make a note of the
column appearance before and after conditioning.
24. Trifluoroacetic acid is more efficient for eluting the analytes, but its methanolic solutions
are unstable and should be prepared each day.
25. Allow the elution solvent to remain and soak the polymeric bed (without vacuum) for
approx 1 min, which may slightly increase the analyte recovery.
26. Evaporation under a stream of nitrogen is simpler and can be performed simultaneously
on several samples using a multiple nitrogen sparger. There is a risk of cross-contamination between samples. Repeated rinsing under continuous sonication is necessary to ensure quantitative recoveries.
27. The standard solutions of halogenated phenoxyacids should be prepared each day from
stock solutions and fresh running buffer.
28. The protocol is reported for a Bio-Rad Capillary Electrophoresis model BioFocus 2000.
Different instruments could require slightly different procedures.
29. Many commercial software programs calculate peak area corrected for the time corresponding to the peak maximum. This correction is necessary because in capillary electrophoresis the velocity of the analytes is not constant.
30. The protocol is reported for an Econosphere 25 cm × 4.6 mm id filled with 5-µm C18
reversed-phase packing (Alltech). Different C18 columns require slightly different elution conditions.
References
1. Thurman, E. M. and Mills, M. S. (1986) Solid-Phase Extraction—Principles and Practice. Wiley-Interscience, New York.
2. Pichon, V. (2000) Solid-phase extraction for multiresidue analysis of organic contaminants in water. J. Chromatogr. A 885, 195–215.
3. Wells, M. J. M. and Yu, L. Z. (2000) Solid-phase extraction of acidic herbicides. J.
Chromatogr. A 885, 237–250.
4. Bruzzoniti, M. C., Sarzanini, C., and Mentasti, E. (2000) Preconcentration of contaminants in water analysis. J. Chromatogr. A 902, 289–309.
5. Hage, D. S. (1998) Survey of recent advances in analytical applications of immunoaffinity
chromatography. J. Chromatogr. B 715, 3–28.
6. Van Emon, J. M., Gerlach, C. L., and Bowman, K. (1998) Bioseparation and bioanalytical
techniques in environmental monitoring. J. Chromatogr. B 715, 211–228.
7. Hennion, M. C. and Pichon, V. (2003) Immuno-based sample preparation for trace analysis. J. Chromatogr. A 1000, 29–52.
8. Sellergren, B. (ed.). (2000) Molecular Imprinted Polymers—Man Made Mimics of Antibodies and Their Applications in Analytical Chemistry. Elsevier, Amsterdam.
9. Haupt, K. (2003) Imprinted polymers—tailor-made mimics of antibodies and receptors.
Chem. Commun. 21, 171–178.
10. Zimmerman, S. C. and Lemcoff, N. G. (2004) Synthetic hosts via molecular imprinting—
are antibodies realistically possible? Chem. Commun. 7, 5–14.
11. Andersson, L. I. (2000) Molecular imprinting for drug bioanalysis. A review on the application of imprinted polymers to solid-phase extraction and binding assay. J. Chromatogr.
B 739, 163–173.
Molecular Imprinted Solid-Phase Extraction
433
12. Lanza, F. and Sellergren, B. (2001) Molecularly imprinted extraction materials for highly
selective sample cleanup and analyte enrichment. Adv. Chromatogr. 41, 138–173.
13. Martin-Esteban, A. (2001) Molecularly imprinted polymers: new molecular recognition
materials for selective solid-phase extraction of organic compounds. Fresenius J. Anal.
Chem. 370, 795–802.
14. Ensing, K., Berggren, C., and Majors, R. E. (2001) Selective sorbents for solid-phase
extraction based on molecularly imprinted polymers. LC–GC 10, 942–954.
15. Baggiani, C., Giraudi, G., Giovannoli, C., Trotta, F., and Vanni, A. (2000) Chromatographic characterization of molecularly imprinted polymers binding the herbicide 2,4,5trichlorophenoxyacetic acid. J. Chromatogr. A 883, 119–126.
16. Baggiani, C., Giovannoli, C., Anfossi, A., and Tozzi, C. (2001) Molecularly imprinted
solid-phase extraction sorbent for the clean-up of chlorinated phenoxyacids from aqueous
samples. J. Chromatogr. A 938, 35–44.
Automated Trace Analysis of Pesticides
435
32
Automated Trace Analysis of Pesticides in Water
Euphemia Papadopoulou-Mourkidou, John Patsias, and Anna Koukourikou
Summary
An automated system appropriate for the analysis of a variety of chemical classes of
pesticides and conversion products in water is presented. The system is based on the online solid-phase extraction (SPE) of target solutes followed by high-performance liquid
chromatography (HPLC) tandem photodiode array/postcolumn derivatization/fluorescence detection (PDA/PCD/FLD). SPE is carried out on Hysphere-GP (10 × 2 mm)
reversed-phase cartridges using the automated PROSPEKT system. Aliquots of 100 mL
acidified (pH 3.0) samples are processed. The on-line HPLC analysis is carried out on a
C18 analytical column eluted with a binary gradient of 10 mM phosphate buffer and an
acetonitrile/water (90:10 v/v) mixture. Solutes are tentatively identified by tandem PDA/
PCD/FLD. The PDA detector is used as a general-purpose detector; the FLD is useful for
confirmation of N-methyl-carbamate and N-methyl-carbamoyloxime pesticides, which
are postcolumn derivatized with o-phthalaldehyde and N,N-dimethyl-2-mercaptoethylamine-hydrochloride after hot alkaline hydrolysis. The entire analytical system is
controlled and monitored by a single computer operated by the chromatographic software. Solute recoveries from water samples are better than 80%, except for some highly
polar and highly hydrophobic compounds; for these compounds, the respective recoveries are in the range of 10–80%. The limits of identification, based on the PDA detector,
are in the range 0.02–0.1 µg/L for the majority of target analytes; the limits of detection
of the PCD/FLD system are in the range 0.005–0.02 µg/L for all amenable analytes.
Key Words: Automation; liquid chromatography; pesticides; postcolumn
derivatization; solid-phase extraction; water analysis.
1. Introduction
Automation is of significant importance in modern pesticide trace analysis in water, and fully automated systems operated in user-unattended mode have been reported.
Most of them are based on combined solid-phase extraction (SPE) of analytes from
water samples with high-performance liquid chromatographic (HPLC) analysis
involving on-line elution of the adsorbed analytes from the SPE cartridges by the flow
of the mobile phase of the HPLC system (1–4). SPE on reversed-phase materials proFrom: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
435
436
Papadopoulou-Mourkidou, Patsias, and Koukourikou
vides, when compared to conventional liquid–liquid preconcentration techniques, significant advantages, such as less solvent consumption, limited operator involvement,
and high potential for automation, especially when combined with on-line HPLC
analysis. Automated systems based on on-line SPE–gas chromatographic (GC) analysis have also been reported (5,6), but their application range is limited because parent
compounds of many chemical groups of pesticides, especially those of the herbicides,
and most major known conversion products of pesticides, are not GC amenable
because of low volatility and increased thermolability. Even though GC and liquid
chromatography (LC) are viewed as supplementary techniques in pesticide trace analysis, liquid chromatography is the first choice, especially regarding analysis of polar
and thermolabile compounds (7).
Analyte detection in LC analysis has been performed traditionally using an
ultraviolet-visible (UVis) detector. Even though this detector is of medium sensitivity
and selectivity, it is preferred because of the ease and low cost of operation, the good
signal stability, the high application range, and in the case of use of a photodiode array
detector, the on-line acquisition of UV spectra is possible, providing valuable information for the tentative identification of sought analytes. Depending on the physicochemical properties of the target analytes, other means of detection have also been
exploited. Fluorescence detectors are quite selective and sensitive; however, their application range in pesticide trace analysis is very limited because a few pesticides
exhibit inherent fluorescence; these are used mainly in combination with a
derivatization step, producing fluorescent derivatives before (precolumn) or after
(postcolumn) the liquid chromatographic analysis (1,2). Mass spectrometric detectors
have also been introduced for analyte detection in liquid chromatographic analysis,
and many applications have been already reported (8–14).
In this chapter, a multiresidue analytical method for pesticide determination in water at trace levels based on the on-line coupling of SPE and HPLC is described. Analyte
detection is performed by photodiode array and fluorescence detectors operated in
tandem mode. The photodiode array detector is used as a general-purpose detector; the
fluorescence detector is considered only for the confirmation of N-methyl-carbamate
and N-methyl-carbamoyloxime insecticides after hot alkaline hydrolysis and
derivatization with o-phthalaldehyde and N,N-dimethyl-2-mercaptoethylamine-hydrochloride with the derivatization step performed on-line right after the elution of solutes from the diode array detector.
2. Materials
2.1. Reagents
1. Stock solutions of target pesticides: Prepare stock solutions of individual analytes
at 1 mg/mL in methanol; add a few drops of 3 N hydrochloric acid in solutions of
hydroxyatrazine, hydroxysimazine, and simazine to facilitate dissolution. Stock solutions
are prepared annually and stored in Teflon-lined capped vials under deep freeze (<−20°C).
2. Mixed working calibration solutions: Prepare mixed calibration solutions at concentrations of 50, 25, 10, 5, 2.5, 1, 0.5, 0.25, 0.1, and 0.05 µg/mL in methanol; calibration
solutions are prepared every 2 mo and stored under deep freeze (see Note 1).
3. Mobile phase solvent A: prepare a 10 mM KH2PO4/H3PO4 aqueous buffer of pH 3.2;
prepare solution daily.
Automated Trace Analysis of Pesticides
437
4. Mobile phase solvent B: Prepare an acetonitrile/water (90:10 v/v) mixture.
5. Derivatization reagent 1: Prepare a 0.2% NaOH aqueous solution, pH 13.0.
6. Derivatization reagent 2: Prepare a 0.01% o-phthalaldehyde and 0.2% N,N-dimethyl-2mercaptoethylamine-hydrochloride solution dissolved in an aqueous buffer consisting of
0.3% boric acid and 0.09% NaOH at pH 9.1; prepare solution daily.
7. Prepare 3 N sulfuric acid and 3 N hydrochloric acid solutions.
8. Membrane filters for aqueous solutions with 0.2-µm pore diameter.
9. A reversed-phase C18 analytical column (150 × 4.6 mm, dp = 5 µm) (e.g., Nucleosil 100/
5 C18 reversed-phase analytical column, Macherey-Nagel, Duren, Germany).
10. Disposable SPE cartridges suitable for the PROSPEKT automated solid-phase extraction
system (e.g., Hysphere-GP, 20 × 2 mm, Spark Holland, Emmen, The Netherlands).
2.2. Instrumentation
1. PROSPEKT automated solid-phase extraction system (e.g., Spark Holland) or other
equivalent.
2. HPLC system appropriate for at least linear binary gradient elution.
3. Autosampler suitable for loop flow injections in HPLC systems equipped with a six-port,
two-position switching valve and a 20-µL or lower injection loop.
4. UV photodiode array detector (e.g., model 996, Waters, Milford, MA) with spectrum
resolution of at least 1.2 nm.
5. Millenium software (Waters) for data treatment.
6. Postcolumn derivatization system (e.g., model Prometheus 300, Rigas Labs, Thessaloniki,
Greece) equipped with two reaction coils, with the first coil heated and thermostated with
an accuracy of ±0.1°C; two pulse-dampened reagent pumps with one-way valves in the
reagent influent lines; and a 500-psi adjustable backpressure regulator. All parts of the
system must be constructed by proper material to withstand strong alkaline conditions.
7. Fluorescence detector (e.g., model Spectroflow 980 fluorescence detector, Kratos,
Ramsey) with variable and adjustable excitation and emission wavelengths.
8. Personal computer operated under a proper HPLC software supporting the installed analytical equipment.
9. The HPLC system must be connected with the PROSPEKT system in such a way that the
adsorbed analytes on the SPE cartridge to be eluted by the mobile phase flow onto the
analytical column in the back-flush mode. A flow diagram of the analytical system is
presented in Fig. 1.
3. Methods
3.1. Protocol and Overview
3.1.1. Sample Preparation
Centrifuge water samples for the precipitation of suspended solids; centrifugation
for 30 min at 3000g is proposed as the starting point (see Note 2). Transfer the supernatant to a clean glass container and adjust the pH to 3.0 by addition of 3 N sulfuric
acid (see Note 3).
3.1.2. SPE of Samples
Program the PROSPEKT to perform sample SPE on disposable reversed-phase cartridges following four steps: (1) cartridge conditioning with a water-miscible organic
solvent, followed by pure water; (2) sample loading; (3) cartridge washing; and (4)
on-line analyte desorption.
438
Papadopoulou-Mourkidou, Patsias, and Koukourikou
438
Fig. 1. Simplified flow diagram of the analytical system.
Automated Trace Analysis of Pesticides
439
Table 1
Mobile Phase Composition and Flow Rate Settings
Time (min)
00
03
35
40
45
50
Solvent B (%)
Flow rate (mL/min)
5
20
100
100
5
5
1.00
1.00
1.00
1.40
1.25
1.00
The proposed method was validated by using 100-mL sample aliquots extracted on
Hysphere-GP (10 × 2 mm) disposable reversed-phase SPE cartridges at a flow rate of
4 mL/min. SPE cartridges were previously conditioned by elution with 10 mL acetonitrile and 10 mL water at a flow rate of 4 mL/min. After sample loading, SPE cartridges
were washed with 2 mL of water at a flow rate of 2 mL/min and placed on-line with
the mobile phase flow of the HPLC system in such a way that the adsorbed analytes
were eluted onto the analytical column in the back-flush mode (see Note 4).
3.1.3. HPLC Analysis
Prepare the HPLC system equipped with an alkaline-bonded silica reversed-phase
analytical column eluted with a binary mobile phase consisting of aqueous buffer/
acetonitrile mixture.
The proposed method was validated using a C18 reversed-phase analytical column
(1.5 × 4.6 mm, dp = 5 µm) and a binary gradient mixture of a 10 mM phosphate buffer
at pH 3.2 (solvent A) and an acetonitrile/water (90:10 v/v) mixture (solvent B) as a
mobile phase; the gradient composition and the flow rate settings are presented in
Table 1 (see Notes 5 and 6).
3.1.4. Photodiode Array Detection
Operate the photodiode array detector in the range 190–400 nm and at a spectrum
resolution of 1.2 nm. The data acquisition rate must be in compliance with the width of
the eluted peaks; a value of 2 spectra/s is proposed (see Note 7). After data acquisition,
chromatograms at various wavelengths (depending on the absorption spectra of the
target analytes) are reconstructed, and the eluted peaks with a signal-to-noise ratio (S/
N) ⱖ 3 are located. Analyte detection is based both on retention time and UV absorption spectra match. Spectra from the top of each chromatographic peak, properly corrected with the background spectrum, are compared with target analyte reference
spectra stored in custom-created libraries, and matches above a predetermined threshold fit and within a predetermined retention time window are reported (see Note 8).
The identification limits of the target analytes in water are determined as the lower
concentration levels at which the respective peaks could be detected at S/N ⱖ 3 and
identified according to their UV spectra.
440
Papadopoulou-Mourkidou, Patsias, and Koukourikou
3.1.5. Postcolumn Derivatization of the N-Methyl-Carbamates
The postcolumn derivatization system is connected at the outlet of the photodiode
array detector. Hot alkaline hydrolysis of the N-methyl-carbamates and N-methylcarbamoyloximes producing methylamine is performed in a 300-µL reaction coil
thermostated at 100°C by a 0.2% NaOH aqueous solution at pH 13.0 (reagent 1) introduced before the reaction coil at a flow rate of 0.3 mL/min. The produced methylamine is subsequently reacted in a second 500-µL coil operated at room temperature
with a solution consisting of 0.01% o-phthalaldehyde and 0.2% N,N-dimethyl-2mercaptoethylamine-hydrochloride dissolved in an aqueous buffer consisting of 0.3%
boric acid and 0.09% NaOH at pH 9.1 (reagent 2) introduced before the reaction coil
at a flow rate of 0.3 mL/min to produce a highly fluorescent indole derivative (see
Note 9).
3.1.6. Fluorescence Detection
Fluorescence detection of the N-methyl-carbamates and N-methyl-carbamoyloximes after their postcolumn derivatization is performed using an excitation wavelength of 330 nm and an emission wavelength of 465 nm. The data acquisition rate, as
for the photodiode array detector, must be in compliance with the width of the eluted
peaks; a value of 2 measurements/s is proposed. Analyte detection is based strictly on
the retention time of the eluted peaks (see Note 10). The detection limits of the target
analytes in water are determined as the lower concentration levels at which the respective elution peaks could be detected at S/N ⱖ 3.
3.1.7. Analyte Quantification
Detected analytes are quantified via external standard calibration curves prepared
by loop flow injections of the mixed working calibration solutions; 10-point external
standard calibration curves corresponding to a 1- to 1000-ng injected amount (for 20µL injections) are prepared for each analyte and for both detectors when appropriate
(N-monomethyl-carbamates). The concentration of the pesticides in the samples is
given by the formula:
Analyte concentration (µg/L) =
Calculated analyte amount (absolute value, ng)/Sample volume (mL)
3.1.8. Automation
The analytical system is fully automated and can be operated user unattended. This
is accomplished either by employing a proper software controlling all different parts
of the analytical equipment or via the “external events” of the PROSPEKT system
delivering simple run/stop commands to other devices of the analytical system ordering the run of preprogrammed triggered cycles.
3.1.9. Method Validation
After the selection of operating conditions, the performance of the analytical method
is fully validated by calculating all performance parameters like chromatographic behavior (retention time, peak width, and asymmetry factor of the eluted peaks), recoveries, and detection limits for all target analytes (see Notes 11 and 12). Method
Automated Trace Analysis of Pesticides
441
variability and reproducibility are also calculated. Complete method validation is subsequently required only when a significant change concerning the instrumentation or
the operating parameters that seriously affects the performance of the method is made.
During normal continuous operation, the performance of the analytical method is recorded by analyzing daily three calibration solutions and three spiked samples made
in environmental water at various concentrations and calculating the performance parameters mentioned above. Their values must be in the range of the predetermined
windows; otherwise, the method must be fully revalidated.
3.2. Work Program for Routine Sample Analysis
1. Prepare mobile phase solvents; filter water and acetonitrile prior to solvent preparation;
degas mobile phase solvents by bath sonication for at least 10 min in case of an on-line
mobile phase degasser is not available. In the last case, during normal daily operation
mobile phase solvents are further degassed by purging helium through the mobile phase
reservoirs for 5 min for each hour of operation.
2. Turn system on; increase linearly the mobile phase flow to the operating value within 5
min or less; turn the first reaction coil heater on and wait for steady-state temperature to
be achieved (see Note 13). Turn the flow of the derivatization reagents on and wait for the
signal of the fluorescence detector to be stabilized; the analytical system is then ready for
operation.
3. Analyze a calibration solution and a spiked field sample and make sure that method performance parameters are in the range of the desired levels.
4. Proceed with daily routine sample analysis sequence by analyzing a mixed working calibration solution and a spiked field sample every five unknown field samples; the concentrations of calibration solutions and those of spiked field samples must alternate between
high and low levels of calibration and measurement, respectively.
5. To turn the analytical system off, proceed as follows: Turn the first reaction coil heater
off and wait for its temperature to decrease below 50°C; turn the flow of the derivatization
reagents off; decrease slowly the mobile phase flow rate to zero within 5 min or less; turn
the system off.
4. Notes
1. Calibration solutions are made in mixtures of 10–30 target analytes, taking into account
their retention times from the selected chromatographic column so that solutes included
in each calibration mixed solution are adequately separated with resolution (R) values
between adjacently eluting solutes higher than 1.
2. Precipitation of the suspended solids is required to avoid problems with clogging of the
SPE cartridges during sample loading. Sample filtration must be avoided when highly
hydrophobic pesticides are included in the target analyte list because they are amenable
to adsorption onto membrane filter surfaces. When hydrophobic compounds are not included in the target analyte list of the indented user, filtration through a membrane filter
with a pore size of 0.45 µm or lower is preferred.
3. Adjustment of sample pH at 3.0 or lower is required when acidic pesticides are included
in target analyte list to suppress their ionization and therefore increase their affinity on
reversed-phase SPE sorbents. Because sample acidification also increases the amount of
the coextracted humic material contained in the field water samples, when acidic compounds are not included in the target analyte list, pH modification is not required.
442
Papadopoulou-Mourkidou, Patsias, and Koukourikou
4. The type of the sorbent material, the dimensions of the SPE cartridge, the elution mode,
and the sample volume play a predominant role not only on the retention capacity of the
target analytes, but also on the chromatographic performance of the overall analytical
system (15). Therefore, the initial selection and later modification of these parameters
must be accompanied by a complete and consistent optimization and validation process.
The type of the SPE sorbing material is selected according to the polarity and water solubility of the target solutes, and the sample volume is selected mainly according to the
desired detection level, taking into account the sensitivity of the detector(s) used. By
increasing sample volume, better detection limits are obtained when solutes are quantitatively retained. Polar solutes, however, are not quantitatively retained when a sample
volume above the respective breakthrough volumes is adopted because of their early
breakthrough from the SPE cartridge. In many cases, however, sample volumes above the
breakthrough volumes of the target solutes result in increased method sensitivity for polar compounds regardless of their reduced extraction recoveries (15,16). On the contrary,
highly hydrophobic solutes exhibit higher extraction recoveries as the sample volume is
increased (15,17), probably because of the partial saturation of the secondary retention
sites on the surfaces of the transfer lines prior to introduction onto the SPE cartridge.
Sample volume also plays a predominant role in the shape of the eluted peaks. The width
and asymmetry factor of the eluted peaks are increased with increasing sample volume.
This is more significant in the case of cartridges packed with sorbent materials of high
retention capacity (i.e., Hysphere-GP) and less significant or negligible for other types of
sorbents with lower retention capacity (15). Cartridge geometry (length and diameter)
plays a predominant role in the shape of the eluted peaks. Large-dimension cartridges
contain more sorbent material and provide higher solute retention; however, they result in
poor chromatographic performance when coupled on-line with HPLC analysis. Long cartridges provide wide elution peaks from the analytical column; thus, cartridges longer
than 10 mm are rarely employed. Cartridge diameter also must be below a specific percentage of the diameter of the analytical column for narrow elution peaks to be achieved
because of better refocusing of the eluted analytes onto the analytical column. The effect
is more intense in the case of forward-flush elution and in the case of cartridges packed
with sorbents of high retention capacity when compared to the sorbing capacity of the
packing material of the analytical column (as in the case of cartridges packed with
Hysphere-GP material and C18 analytical column) (15). In any case, back-flush elution
provides narrower analyte elution peaks and must be preferred.
5. Acidification of the mobile phase is required when acidic pesticides are to be analyzed to
suppress their ionization. Phosphate buffer has been preferred because of its low UV
absorbance. Acidification of the mobile phase is also suppressing the ionization of the
residual silanol groups on the bonded-silica surface and permits the usage of lower cost,
not end-capped analytical columns. The retention times of ionizable pesticides of acidic
(phenoxy-alkanoic acids, sulfonylureas, picolinic acids, imidazolinones, and other herbicides) and basic (i.e., triazine herbicides) behavior depend strongly on the mobile phase
pH, and it is therefore strongly recommended that the pH of the mobile phase be adjusted
precisely to obtain reproducible data. When acidic compounds are not included in the
target analyte list, acidification of the mobile phase is not required; however, in this case
end-capped analytical columns or proper mobile phase modifiers should be included to avoid
secondary retention phenomena caused by the presence of ionized residual silanol groups.
6. A different type of reversed-phase analytical column with respect to the packing material
or column dimensions and different mobile phase composition or gradient regime could
Automated Trace Analysis of Pesticides
7.
8.
9.
10.
11.
443
also be used according to the intended user’s special needs and availability of new commercial chromatographic products. Every change in the operational parameters, however,
should be first optimized and validated carefully, taking into account not only the chromatographic performance of the column, but also the compatibility with the selected sorbent type and geometry of the SPE cartridges (see Note 4).
Increasing the acquired spectrum range, spectrum resolution, and acquisition rate increases the detection quality; however, the amount of raw data and the required time for
data processing are also increased. During initial selection or later modification of these
parameters, the storage capacity and the processing rate of the available computer hardware must be taken into account.
UV absorption maxima of some analytes are affected by the analytical conditions used
during data acquisition (mainly the mobile phase pH), and it is therefore strongly recommended to compare spectra acquired only under the same experimental conditions.
The flow rates of the derivatization reagents must be optimized with respect to the HPLC
mobile phase flow rate for maximum sensitivity to be achieved.
Even though the derivatization reactions are very selective for the N-methyl-carbamates
and N-methyl-carbamoyloximes, interferences from the matrix still appear in the respective chromatograms (1,2), and data derived from the fluorescence detector cannot be used
solely for analyte identification; data derived from the fluorescence detector are used in
complementary support of the findings of the photodiode array detector.
The proposed method using the experimental conditions described in Subheading 3. and
operated on a system consisting of the apparatus described in Subheading 2. and shown
in Fig. 2 has been validated for more than 170 pesticides and conversion products; included among the target solutes are representative members of most chemical families of
pesticides, also including 23 N-methyl-carbamate and N-methyl-carbamoyloxime compounds amenable for postcolumn derivatization/fluorescence detection. The target analyte
list, however, can be expanded furthermore depending on the special needs of the intended users. Analyte recoveries derived from the analysis of spiked water samples are
presented in Tables 2 and 3. Recovery values are better than 80% for the majority of
targeted analytes, except for the highly polar and the highly hydrophobic compounds.
The highly polar analytes clopyralid, picloram, hydroxysimazine, and hydroxyatrazine
exhibit reduced recoveries (11, 49, 19, and 75%, respectively, at a concentration level of
2 µg/L; see Table 2), because of their early breakthrough from the SPE cartridges. The
recoveries of the highly hydrophobic compounds (organochlorines, pyrethroids, hydrophobic organophosphates, and other hydrophobic compounds) are below 80% because of
sorption onto surfaces of transfer lines of the SPE system; recoveries increase as the
sample volume increases (15,17). Analyte identification limits calculated on the basis of
data acquired by the photodiode array detector are presented in Table 2. Values range
from 0.02 to 0.1 µg/L for the majority of the targeted analytes. Fluorescence detection
provides better detection limits (0.005–0.02 µg/L) for amenable compounds; however, as
mentioned in Note 7, these findings cannot solely support analyte identification in water,
and the identification limits of the proposed analytical method are those provided by the
photodiode array detector. A sample chromatogram derived from the analysis of a field
water sample (River Loudias, Macedonia, Greece) is presented in Fig. 2. By means of the
photodiode array detector, atrazine and molinate (peaks 2 and 3, respectively) at respective concentrations of 0.03 and 15.9 µg/L are determined. In the same sample, caffeine
(peak 1) is also detected and quantified (0.67 µg/L). The “hill-type” peak in the first half
of the chromatogram (Fig. 2A) is caused by elution of humic substances present in sur-
444
Papadopoulou-Mourkidou, Patsias, and Koukourikou
Table 2
Retention Times tR, Quantification Wavelengths λquan, Recoveries % (Relative Standard Deviation
[RSD] %), and Detection Limits of the Target Analytes
tR
λquan
No.
Analyte
(min)
(nm)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
Clopyralid
Aldicarb sulfoxide
Picloram
Aminocarb
Butoxycarboxim
Aldicarb sulfone
Hydroxysimazine
Oxamyl
Methomyl
Imazapyr
Desisopropylatrazine
Hydroxyatrazine
Dicamba
Carbendazim
Metamitron
Imidacloprid
Mevinphos 1
Diketometribuzin
3-OH carbofuran
Desethylatrazine
Chloridazon
Metolachlor sulfonic acid
Desaminodiketometribuzin
Dioxacarb
Dimethoate
Mevinphos 2
Butocarboxim
Oxycarboxin
Desaminometribuzin
Aldicarb
Bentazon
Metoxuron
Imazamethabenz
Bromacil
Pirimicarb
Terbacil
Metolcarb
Paraoxon methyl
Imazaquin
Metribuzin
Simazine
Carbofuran
2,4-D
Thophanate methyl
4.4
7.7
7.7
8.2
8.7
8.8
8.8
8.9
9.1
10.1
10.4
10.6
11.1
11.5
12.2
12.5
12.5
12.6
12.9
12.9
13.0
13.5
13.5
13.7
13.9
14.5
15.1
15.2
15.4
15.6
15.7
16.3
16.4
16.4
16.7
16.8
16.9
16.9
17.2
17.2
17.3
17.8
18.0
18.0
221, 280
215
223
215
215
215
240
220
233
215, 240
214
241
215
215
215, 308
270
215
259
215
215
228, 285
215
260
215
215
216
215
253
237
215
240, 310
215, 245
215
215, 276
219
215, 280
215
215, 273
249
215, 294
222
215
229, 284
215, 265
Recovery %
(RSD %, n = 3)
0.2 µg/L
12 (10)
99 (8)
54 (11)
101 (14)
99 (11)
105 (12)
21 (9)
103 (9)
102 (9)
108 (10)
108 (4)
78 (7)
108 (11)
91 (10)
106 (8)
99 (5)
104 (5)
90 (4)
94 (8)
105 (4)
108 (6)
106 (7)
102 (4)
101 (8)
96 (7)
99 (6)
104 (6)
103 (6)
103 (6)
96 (8)
104 (7)
103 (6)
102 (6)
103 (8)
102 (3)
107 (7)
100 (10)
102 (2)
103 (7)
102 (4)
104 (6)
99 (2)
104 (4)
88 (12)
Detection
limit
2 µg/L
(µg/L)
11 (4)
97 (2)
49 (3)
97 (3)
98 (3)
98 (4)
19 (6)
98 (3)
100 (2)
100 (5)
99 (1)
75 (5)
100 (5)
86 (7)
101 (2)
97 (3)
99 (3)
86 (1)
91 (6)
100 (1)
100 (2)
99 (2)
100 (2)
95 (2)
95 (5)
96 (3)
99 (3)
99 (3)
100 (3)
94 (5)
98 (2)
99 (2)
100 (2)
100 (4)
99 (1)
101 (3)
99 (1)
99 (1)
99 (3)
99 (2)
101 (3)
98 (2)
100 (1)
83 (7)
0.20
0.10
0.10
0.20
0.10
0.10
0.10
0.10
0.10
0.10
0.02
0.05
0.05
0.10
0.02
0.05
0.10
0.02
0.10
0.02
0.02
0.10
0.02
0.10
0.10
0.10
0.10
0.05
0.02
0.10
0.10
0.02
0.05
0.05
0.05
0.05
0.10
0.05
0.05
0.02
0.02
0.10
0.10
0.05
(continued)
Automated Trace Analysis of Pesticides
445
Table 2 (Continued)
Retention Times tR, Quantification Wavelengths λquan, Recoveries % (Relative Standard Deviation
[RSD] %), and Detection Limits of the Target Analytes
tR
λquan
No.
Analyte
(min)
(nm)
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
Bendiocarb
Simetryne
Propoxur
MCPA
Thiodicarb
Triasulfuron
Carbaryl
Thiofanox
Terbumeton
Fluometuron
Ethiofencarb
Chlortoluron
Carboxin
2,4,5-T
Atrazine
Dichlorprop
Isoproturon
Monolinuron
Isoprocarb
Hydroxymetolachlor
2,4-Dichlorophenol
Diuron
Paraoxon ethyl
Metobromuron
Propachlor
Ametryne
Fenobucarb
Thiophanate ethyl
Nuarimol
Methiocarb
Propazine
Promecarb
Propanil
Dicloran
2,4-DB
Phosmet
Desmedipham
Linuron
Terbuthylazine
2,4,5-Trichlorophenol
Fenarimol
Naptalam
Ethofumesate
Azinphos methyl
18.5
18.5
18.7
18.7
18.9
19.2
19.7
19.9
19.9
20.0
20.2
20.2
20.2
20.3
20.3
20.4
20.4
20.6
20.9
20.9
21.2
21.2
21.4
21.5
21.8
22.3
22.4
22.5
22.5
22.6
22.9
23.1
23.1
23.2
23.4
23.5
23.9
24.0
24.1
24.3
24.3
24.5
24.6
24.8
215, 276
222
215
228, 279
235
223, 286
215
215
219
243
215
215, 243
252, 293
215, 288
222
230, 285
215
245
215
215
229, 286
250
215, 273
248
215
222
215
215, 267
215
215
222
215
215, 250
215, 360
230, 285
215
236
215, 249
223
215, 292
215
222
226, 279
223, 285
Recovery %
(RSD %, n = 3)
0.2 µg/L
100 (8)
102 (3)
101 (4)
101 (6)
105 (3)
100 (7)
100 (7)
99 (11)
103 (8)
102 (5)
89 (5)
102 (4)
107 (9)
106 (5)
103 (3)
109 (6)
103 (5)
102 (7)
107 (6)
103 (9)
102 (8)
104 (3)
103 (5)
102 (8)
106 (6)
106 (7)
106 (9)
089 (10)
100 (6)
101 (8)
101 (6)
103 (7)
103 (5)
101 (7)
98 (5)
102 (6)
102 (6)
102 (7)
102 (7)
100 (6)
107 (8)
108 (9)
106 (4)
104 (5)
Detection
limit
2 µg/L
(µg/L)
99 (2)
99 (1)
100 (1)
98 (2)
101 (2)
99 (1)
99 (1)
96 (8)
100 (3)
100 (1)
86 (1)
99 (1)
101 (1)
100 (3)
101 (1)
101 (1)
98 (3)
100 (2)
98 (2)
100 (3)
100 (4)
10.0 (1)
98 (2)
101 (1)
101 (2)
100 (1)
100 (5)
85 (5)
97 (3)
97 (1)
101 (2)
101 (4)
99 (1)
98 (4)
97 (1)
100 (1)
98 (2)
100 (1)
101 (1)
96 (2)
101 (2)
102 (3)
101 (2)
100 (2)
0.10
0.02
0.10
0.10
0.10
0.05
0.02
0.20
0.05
0.02
0.10
0.02
0.05
0.05
0.02
0.10
0.02
0.02
0.10
0.10
0.05
0.02
0.05
0.02
0.10
0.02
0.10
0.05
0.05
0.10
0.02
0.10
0.02
0.05
0.10
0.05
0.05
0.02
0.02
0.02
0.05
0.02
0.10
0.10
(continued)
446
Papadopoulou-Mourkidou, Patsias, and Koukourikou
Table 2 (Continued)
Retention Times tR, Quantification Wavelengths λquan, Recoveries % (Relative Standard Deviation
[RSD] %), and Detection Limits of the Target Analytes
tR
λquan
No.
Analyte
(min)
(nm)
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
Propyzamide
Prometryne
Molinate
Diflubenzuron
Napropamide
Phenmedipham
Fenoxycarb
Fenamiphos
Bitertanol
Parathion methyl
Alachlor
Acetochlor
Fenitrothion
Metolachlor
Chlorothalonil
Diphenylamine
Azinphos ethyl
Bupirimate
Penconazole
Diclofluanid
EPTC
Tolyfluanid
Iprodione
Fenthion
Prochloraz
Parathion ethyl
Pyrazophos
Hexaflumuron
Benzoylprop ethyl
Pirimiphos methyl
Chlorpyriphos methyl
Cycloate
Chlorobenzilate
Thiobencarb
Pretilachlor
Dialifos
Methoxychlor
Chloropropylate
Furathiocarb
Diclofop methyl
Tetradifon
Temephos
Fluazifop butyl
Tralkoxydim
24.9
24.9
25.0
25.1
25.1
25.1
25.2
25.2
25.2
25.4
26.4
26.6
26.7
26.7
26.8
27.0
27.2
27.2
27.3
27.4
27.6
28.5
28.6
28.7
28.8
29.0
29.2
29.4
29.6
30.2
30.5
30.5
30.8
30.9
31.0
31.5
31.9
32.3
32.5
32.6
33.2
33.3
33.3
33.3
215
222
215
215, 257
215, 292
236
228, 279
215, 252
215, 250
215
215
215
215, 269
215
232
284
223, 286
245
215
215
215
215
217, 249
215
215
215, 275
245
215, 255
215
247
229, 289
215
215
220
215
222
228
225
215, 281
215
215
215, 252
224, 268
254
Recovery %
(RSD %, n = 3)
0.2 µg/L
106 (7)
106 (5)
103 (6)
106 (9)
105 (8)
93 (9)
105 (7)
101 (6)
100 (4)
102 (3)
106 (9)
107 (8)
104 (3)
103 (6)
100 (5)
105 (7)
103 (5)
103 (4)
99 (7)
89 (10)
104 (7)
97 (8)
105 (7)
101 (6)
103 (6)
102 (3)
103 (4)
103 (10)
103 (2)
101 (4)
100 (7)
105 (4)
102 (7)
93 (7)
102 (7)
96 (9)
107 (8)
108 (10)
85 (8)
92 (4)
96 (8)
68 (11)
87 (5)
110 (9)
Detection
limit
2 µg/L
(µg/L)
101 (4)
99 (2)
101 (2)
100 (1)
100 (3)
89 (7)
100 (3)
99 (2)
98 (2)
98 (1)
101 (2)
98 (3)
99 (1)
101 (2)
98 (3)
98 (6)
99 (2)
100 (1)
96 (3)
83 (7)
100 (3)
93 (5)
100 (3)
98 (3)
99 (2)
99 (2)
100 (1)
97 (6)
100 (1)
98 (2)
97 (3)
100 (1)
99 (2)
89 (2)
99 (2)
95 (6)
101 (4)
102 (6)
82 (2)
89 (1)
94 (5)
63 (6)
85 (3)
99 (3)
0.05
0.05
0.10
0.02
0.05
0.05
0.05
0.10
0.02
0.05
0.10
0.10
0.10
0.10
0.02
0.02
0.10
0.10
0.05
0.10
0.10
0.10
0.10
0.10
0.10
0.05
0.02
0.02
0.10
0.02
0.05
0.10
0.10
0.05
0.10
0.05
0.10
0.10
0.10
0.10
0.05
0.10
0.10
0.10
(continued)
Automated Trace Analysis of Pesticides
447
Table 2 (Continued)
Retention Times tR, Quantification Wavelengths λquan, Recoveries % (Relative Standard Deviation
[RSD] %), and Detection Limits of the Target Analytes
tR
λquan
No.
Analyte
(min)
(nm)
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
Pendimethalin
Dicofol
Oxadiazon
Benfluralin
Trifluralin
Pirimiphos ethyl
Carbophenothion ethyl
Flucythrinate
λ-Cyhalothrin
Isopropalin
p,p′-DDT
Fenvalerate
p,p′-DDE
Decamethrin
o,p′-DDT
Permethrin-trans
Permethrin-cis
o,p′-DDE
Bifentrin
Carbosulfan
33.5
33.7
33.8
33.9
34.1
34.2
34.5
35.5
35.7
35.8
35.9
36.8
37.1
37.1
37.5
37.8
38.1
38.4
38.6
39.0
240
230
215, 292
215, 275
215, 274
247
215, 263
215
215
215, 242
236
215
248
215
235
215
215
246
215
215, 282
Recovery %
(RSD %, n = 3)
0.2 µg/L
92 (7)
76 (11)
101 (8)
83 (9)
78 (8)
99 (7)
64 (8)
39 (11)
39 (10)
76 (9)
58 (10)
46 (9)
52 (11)
48 (8)
49 (12)
44 (7)
39 (10)
47 (10)
46 (7)
59 (8)
Detection
limit
2 µg/L
(µg/L)
89 (4)
71 (7)
99 (1)
80 (5)
77 (5)
90 (2)
61 (7)
34 (7)
37 (5)
70 (4)
52 (6)
42 (4)
47 (7)
41 (3)
45 (6)
40 (5)
36 (6)
41 (7)
40 (4)
54 (4)
0.05
0.05
0.05
0.05
0.05
0.02
0.05
0.10
0.10
0.05
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
Data were recorded by the diode array detector. Validation data were calculated by analyzing spiked samples
made in Axios River water samples.
face water samples. Its position on the chromatogram depends on the pH of the mobile
phase (17). By means of the fluorescence detector, 3-OH-carbofuran is determined at a
concentration of 0.009 µg/L. However, the presence of this compound in the sample was
not confirmed by the photodiode array detector as the concentration was lower than its
respective identification limit, and its detection by the fluorescence detector alone is of
limited value. Two other peaks (annotated by an asterisk) not corresponding to any compound from the target analyte list are also recorded. Another chromatogram derived from
the analysis of a groundwater sample is presented in Fig. 3. Carbaryl is detected in the
sample by both fluorescence and diode array detectors at concentrations of 0.11 and 0.12
µg/L, respectively. In the inset, the UV adsorption spectrum match provided by the photodiode array detector is shown. The detection of carbaryl by both detectors increases the
possibility for its positive identification.
12. In unknown samples, poorly separated solutes or solutes with the same retention time are
discriminated on the basis of their UV spectra. In this respect, the postcolumn hydrolysis,
derivatization, and fluorescence detection of eluted solutes provide an additional piece of
information taken into account for the tentative identification of solutes. Among the target analytes included in Table 2, there are certain coeluting solutes that are difficult to be
discriminated on the basis of their respective UV spectra; such a case is the analysis of the
448
Papadopoulou-Mourkidou, Patsias, and Koukourikou
Table 3
Retention Times tR, Recoveries % (Relative Standard Deviation [RSD] %), and Detection Limits
for N-Methyl-Carbamates and N-Methyl-Carbamoyloximes Spiked in Water Samples
tR
Recovery %
(RSD %)
Detection
limit
No.
Analyte
(min)
(0.2 µg/L
2 µg/L
(µg/L)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Aldicarb sulfoxide
Aminocarb
Butoxycarboxin
Aldicarb sulfone
Oxamyl
Methomyl
3-OH carbofuran
Dioxacarb
Butocarboxin
Aldicarb
Metolcarb
Carbofuran
Bendiocarb
Propoxur
Thiodicarb
Carbaryl
Thiofanox
Ethiofencarb
Isoprocarb
Fenobucarb
Methiocarb
Promecarb
Furathiocarb
8.7
9.1
9.4
9.6
9.7
9.9
13.6
14.3
15.9
16.2
17.5
18.4
19.3
18.8
19.5
20.3
20.5
20.7
21.4
23.0
23.2
23.7
33.1
91 (11)
93 (15)
95 (8)
98 (4)
97 (5)
101 (6)
93 (7)
91 (9)
99 (4)
94 (8)
100 (4)
99 (3)
100 (2)
101 (4)
100 (3)
99 (2)
95 (9)
87 (9)
99 (4)
100 (3)
98 (5)
100 (4)
83 (3)
87 (8)
90 (7)
93 (3)
96 (2)
95 (4)
99 (3)
90 (4)
87 (7)
98 (3)
92 (5)
98 (2)
98 (2)
99 (1)
99 (2)
99 (1)
98 (1)
93 (7)
83 (6)
98 (3)
99 (1)
97 (2)
98 (2)
82 (1)
0.010
0.020
0.010
0.010
0.005
0.005
0.005
0.005
0.005
0.005
0.005
0.005
0.005
0.005
0.005
0.005
0.010
0.010
0.005
0.005
0.005
0.005
0.005
Data were recorded by the fluorescence detector.
choroacetanilide herbicides alachlor, acetoclor, and metolachlor, which are commonly
found in field water samples; in such cases, samples should be also analyzed by either
HPLC or GC with mass spectrometry detection.
13. Care must be taken not to heat the reaction coil before the establishment of the mobile
phase flow.
References
1. Patsias, J. and Papadopoulou-Mourkidou, E. (1999) A fully automated system for analysis
of pesticides in water: on-line extraction followed by liquid chromatography–tandem photodiode array/postcolumn derivatization/fluorescence detection. J. AOAC Int. 82, 968–981.
2. Hiemstra, M. and de Kok, A. (1994) Determination of N-methylcarbamate pesticides in
environmental water samples using automated on-line trace enrichment with exchangeable
cartridges and high performance liquid chromatography. J. Chromatogr. 667, 155–166.
Automated Trace Analysis of Pesticides
449
Fig. 2. Chromatogram from the analysis of a water sample taken from the river Loudias
(Macedonia, Greece). (A) data recorded by the diode array detector at 215 nm; peaks are annotated as follows: 1, caffeine; 2, atrazine; 3, molinate. (B) data recorded by the fluorescence
detector; *, matrix interferences (see Note 11).
450
Papadopoulou-Mourkidou, Patsias, and Koukourikou
Fig. 3. Chromatogram from the analysis of a groundwater sample taken from a groundwater
well from the region of Kavala (Macedonia, Greece). Data recorded by the fluorescence detector; the insert of the figure is the UV adsorption spectrum match provided by the diode array
detector.
3. Slobodnik, J., Croenewegen, M. G. M., Brouwer, E. R., Lingeman, H., and Brinkman, U.
A. T. (1993) Fully automated multi-residue method for trace level monitoring of polar
pesticides by liquid chromatography. J. Chromatogr. 642, 359–370.
4. Liska, I., Brouwer, E. R., Ostheimer, A. G. L., Lingeman, H., and Brinkman, U. A. T.
(1992) Rapid screening of a large group of polar pesticides in river water by on-line trace
enrichment and column liquid chromatography. Int. J. Environ. Anal. Chem. 47, 267–291.
5. Pocurull, E., Aguilar, C., Borull, F., and Marce, R. M. (1998) On-line coupling of solidphase extraction to gas chromatography with mass spectrometric detection to determine
pesticides in water. J. Chromatogr. A 818, 85–93.
6. Louter, A. J. H., van Beekvelt, C. A., Montanes, P. C., Slobodnik, J., Vreuls, J. J., and
Brinkman, U. A. T. (1996) Analysis of organic microcontaminants in aqueous samples by
fully automated on-line solid-phase extraction–gas chromatography–mass selective
detection. J. Chromatogr. A 725, 67–83.
7. Liska, I. and Slobodnik, J. (1996) Comparison of gas and liquid chromatography for analyzing polar pesticides in water samples. J. Chromatogr. A 733, 235–258.
Automated Trace Analysis of Pesticides
451
8. Santos, T. C. R., Rocha, J. C., and Barcelo, D. (2000) Determination of rice herbicides,
their transformation products and clofibric acid using on-line solid-phase extraction followed by liquid chromatography with diode-array and atmospheric pressure chemical ionization mass spectrometric detection. J. Chromatogr. A 879, 3–12.
9. Hu, J.-Y., Aizawa, T., and Magara, Y. (1999) Analysis of pesticides in water with liquid
chromatography/atmospheric pressure chemical ionization mass spectrometry. Water Res.
33, 417–425.
10. Crescenzi, C., Di Corcia, A., Guerriero, E., and Samperi, R. (1997) Development of a
multiresidue method for analyzing pesticide traces in water based on solid-phase extraction and electrospray liquid chromatography mass spectrometry. Environ. Sci. Technol.
31, 479–488.
11. Hogenboom, A. C., Jagt, I., Vreuls, R. J. J., and Brinkman, U. A. T. (1997) On-line trace
level determination of polar organic microcontaminants in water using various pre-column–analytical column liquid chromatographic techniques with ultraviolet absorbance and
mass spectrometric detection. Analyst 122, 1371–1377.
12. Slobodnik, J., Hogenboom, A. C., Vreuls, J. J., et al. (1996) Trace-level determination of
pesticide residues using on-line solid-phase extraction–column liquid chromatography
with atmospheric pressure ionization mass spectrometric and tandem mass spectrometric
detection. J. Chromatogr. A 741, 59–74.
13. Chiron, S., Papilloud, S., Haerdi, W., and Barcelo, D. (1995) Automated on-line liquid–
solid extraction followed by liquid chromatography–high-flow pneumatically assisted
electrospray mass spectrometry for the determination of acidic herbicides in environmental waters. Anal. Chem. 67, 1637–1643.
14. Slobodnik, J., van Baar, B. L. M., and Brinkman, U. A. T. (1995) Column liquid chromatography–mass spectrometry: selected techniques in environmental applications for polar
pesticides and related compounds. J. Chromatogr. A 703, 81–121.
15. Patsias, J. and Papadopoulou-Mourkidou, E. (2000) Development of an automated on-line
solid-phase extraction high-performance liquid chromatographic method for the analysis
of aniline, phenol, caffeine and various selected aniline and phenol compounds in aqueous
matrices. J. Chromatogr. A 904, 171–188.
16. Subra, P., Hennion, M. C., Rosset, R., and Frei, R. W. (1988) Recovery of organic compounds from large-volume aqueous samples using on-line liquid chromatographic
preconcentration techniques. J. Chromatogr. 456, 121–141.
17. Papadopoulou-Mourkidou, E. and Patsias, J. (1996) Development of a semi-automated
HPLC-DAD system for screening pesticides at trace levels in aquatic systems of the Axios
River basin. J. Chromatogr. A 726, 99–113.
Analysis of Organotins by GC–HRMS
453
33
Gas Chromatography–High-Resolution Mass
Spectrometry-Based Method for the Simultaneous
Determination of Organotin Compounds in Water
Michael G. Ikonomou and Marc P. Fernandez
Summary
A gas chromatography–high-resolution mass spectrometry (GC–HRMS)-based
method has been developed for the accurate and sensitive determination of nine organotin
compounds in water: tetrabutyltin, tributyltin, dibutyltin, monobutyltin, triphenyltin,
diphenyltin, monophenyltin, tricyclohexyltin, and dicyclohexyltin. Details on procedures
for glassware treatment, sample conditioning, extraction, and derivatization are all provided. In situ derivatization with sodium tetraethylborate is employed to overcome difficulties associated with extracting ionic compounds into an organic solvent from an
aqueous matrix. GC–HRMS conditions under selective ion monitoring mode and quality
control criteria for the positive identification of analytes are presented. Linearity of response and minimal detectable limits are provided for each of the nine compounds, and
the estimates of method limits of detection are 7–29 ng/L based on a 100-mL water
sample. All GC–HRMS quantitative formulas for the calculation of internal standard
recovery and recovery-corrected organotin concentration in unknown samples are provided. Method precision and accuracy are determined using spiked clean water samples
as well as spiked seawater samples used in bioconcentration experiments.
Key Words: Antifouling paints; ethylation; GC–HRMS; organometallic compounds;
seawater; speciation; tributyltin; ultratrace analysis.
1. Introduction
Organotin (OT) compounds, characterized by containing at least one carbon–tin
bond and generally represented as RnSnX(4-n) (n = 1–4; R = alkyl or aryl; X = H, OR′,
halogen, etc.), have been incorporated into many industrial and agricultural biocides
and wood-preserving and antifouling agents. Because of the former widespread use of
these compounds in such products, parent OT compounds and their breakdown products (i.e., di- and monosubstituted OT) have been found in both fresh and saltwater
sources. The importance of accurate OT chemical speciation with a low part-per-bilFrom: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
453
454
Ikonomou and Fernandez
lion limit of detection (LOD) in environmental samples has been acknowledged by
various scientists performing monitoring and ecotoxicological studies on these compounds. Most OT methods published determine environmental concentrations of
tributyltin (TBT), dibutyltin (DBT), monobutyltin (MBT), triphenyltin (TPhT),
diphenyltin (DPhT), monophenyltin (MPhT), tricyclohexyltin (TCyT), dicyclohexyltin
(DCyT), tetrabutyltin (TeBT), fenbutatin oxide (FBTO), or various methyl-, ethyl-, or
propyl-tin compounds (reviewed in refs. 1 and 2).
Gas chromatography (GC) analysis is performed for OT analysis in most cases,
utilizing one of many suitable detection methods, including atomic absorption spectrometry (AAS), atomic emission detection (AED), microwave-induced plasma–
atomic emission spectroscopy (MIP–AES), flame photometric detection (FPD), pulsed
flame photometric detection (PFPD), mass spectrometry (MS), and inductively
coupled plasma–mass spectrometry (ICP–MS) (1,3,4; reviewed in refs. 5–7). However, the main limitations and drawbacks of photometric emission/absorption-based detectors used in OT analysis include a lack of selectivity or sensitivity, limited dynamic
range, or poor calibration stability. In addition, low-resolution MS suffers from interference in the low molecular mass region in which most diagnostic ions for OT appear (2).
To date, high-resolution mass spectrometry (HRMS) has not been evaluated for OT
analysis in environmental samples. This technique is very sensitive and extremely
selective because of the narrow mass channels (10,000 resolution) used to monitor the
target analytes. GC–HRMS-based analysis in conjunction with isotope dilution
quantitation is one of the most robust methodologies used in ultra-trace environmental
analyses. Also, because of the high specificity of the technique, minimum sample size
is required for processing, and this is a substantial advantage in terms of minimizing
potential matrix interferences and cost of analysis.
In this chapter, we describe a GC–HRMS-based methodology for the simultaneous
determination in water of nine OT compounds: TeBT, TBT, DBT, MBT, TPhT, DPhT,
MPhT, TCyT, and DCyT. Details such as (1) sample preparation, (2) instrumental
analysis conditions, (3) quantitation and data treatment, and (4) overall method performance are presented.
2. Materials
1. Laboratory glassware: 100-mL graduated cylinders; 250-mL separatory funnels; 125-mL
round-bottom flasks; hexane-rinsed 15-mL centrifuge tubes (polyethylene); precleaned
glass microvials for GC analysis.
2. Magnetic sector high-resolution mass spectrometer (e.g., Micromass Autospec, EBE
geometry).
3. Gas chromatograph (e.g., Hewlett-Packard HP 5890, Wilmington, DE) equipped with a
split/splitless injector and a temperature-controlled GC–MS interface. The column used
is a 30 m × 0.25 mm id (0.1-µm film) DB-5 capillary column (e.g., J&W, Folsom, CA).
4. OT standard mix: A mix of 1 ng cation/µL mono(n-butyl)tin trichloride (>99% pure),
tri(n-butyl)tin monochloride (>99% pure), mono(n-phenyl)tin trichloride (>99% pure),
di(n-phenyl)tin dichloride (>98% pure), tri(n-phenyl)tin monochloride (>99% pure), di(ncyclohexyl)tin dichloride (>99% pure), and tri(n-cyclohexyl)tin monochloride (>99%
pure); 2 ng cation/µL di(n-butyl)tin dichloride (>99% pure) (Quasimeme programme,
Vrije Universiteit Amsterdam, Amsterdam, Netherlands); and 10 ng cation/µL tetra(n-
Analysis of Organotins by GC–HRMS
5.
6.
7.
8.
9.
455
butyl)tin (>94% pure) (e.g., Alpha Aesar, Ward Hill, MA) in MeOH at −20°C protected
from light for 4 months.
Method surrogate internal standard (ISTD): 1.00 ng cation/µL di(n-propyl)tin (DPrT)
dichloride (e.g., Aldrich Chemical Company Inc., Milwaukee, WI) in MeOH at −20°C
protected from light for 4 months.
Performance standard: 2.77 ng cation/µL tetra(n-pentyl)tin (TePeT; Quasimeme
programme) in toluene at −20°C protected from light for 4 months.
Buffer: 1M NaOAc/acetic acid, pH approx 4.5 at room temperature.
Derivatization reagent: 1% (w/v) sodium tetraethylborate [NaB(Et)4] (Alpha Aestar) in
methanol made fresh as required. Note: this reagent is spontaneously flammable in air
and therefore was prepared under nitrogen.
Miscellaneous reagents: cyclohexane (reagent grade or better); ultrahigh-purity helium
and nitrogen; double-deionized water (on-site Milli-Q® water purification system); 2%
nitric acid (HNO3) bath; 5% dichlorodimethylsilane (DCDMS) in dichloromethane (DCM).
3. Methods
3.1. Sample Preparation
The preparation of liquid water samples for ultratrace GC-based analysis requires a
number of steps: (1) glassware cleaning for ultratrace OT analysis; (2) sample spiking
and ISTD addition; (3) sample conditioning, derivatization, and extraction; and (4)
preparation of calibration standards.
3.1.1. Glassware Cleaning Protocol (see Note 1)
1.
2.
3.
4.
5.
6.
7.
8.
9.
Rinse each piece of glassware with hot tap water several times.
Soak in 2% nitric acid (HNO3), preferably overnight.
Rinse with hot tap water again.
Rinse in a laboratory dishwasher using distilled water without detergent.
Rinse twice with acetone and twice with DCM.
Treat with 5% DCDMS in DCM to deactivate the glassware surfaces.
Rinse twice with DCM to remove excess DCDMS.
Oven bake for 6 h at 325°C (see Note 2).
Rinse twice with acetone and twice with hexane before use.
3.1.2. Batch Composition, Method Validation, and Addition of Standards
1. Each sample processing batch should consist of 13 samples. The batch composition is a
procedural blank (i.e., 100 mL double-deionized water or high-performance liquid chromatography-grade water); nine “real” 100-mL samples (see Note 3), of which one should
be analyzed in duplicate; a spiked sample (i.e., 100 mL double-deionized water or highperformance liquid chromatography-grade water spiked with 50 µL OT standard mix);
and a certified reference material (CRM) (see ref. 8) as well as a calibration standard (see
Subheading 3.1.4.).
2. The overall analytical method is validated in terms of percentage recovery of the spiked
compounds (i.e., accuracy), precision, and long-term stability using spiked samples analyzed in triplicate. Environmental water samples or matrix-free water samples need to be
spiked with 50 µL of the OT standard mix (see Note 4) and be processed in triplicate
through the entire method. Spiked samples should also be included in each batch in which
real samples are to be processed.
456
Ikonomou and Fernandez
3. For quality control purposes, a CRM for the compounds of interest should be included in
the batch.
4. Add 100 µL of surrogate ISTD solution (see Note 4) to all samples, spikes, CRM, and blanks.
3.1.3. Sample Conditioning, Derivatization, and Extraction
1.
2.
3.
4.
5.
6.
7.
8.
9.
Add 10 mL of NaOAc buffer to each sample so that the final pH of the sample is approx 4.5.
Shake samples and add 1 mL of the derivatization reagent (see Note 5).
Immediately shake samples for 1 min, add 50 mL hexane, and shake for 1 min again.
Allow samples to react at room temperature for 30 min and finally shake for 1 min.
Collect upper organic layer into a round-bottom flask and add another 0.5-mL aliquot of
NaB(Et)4 to the aqueous layer of each sample to ensure complete derivatization (see Note 6).
Repeat hexane extraction with an additional 50-mL aliquot.
Combine both organic extracts and reduce by rotary evaporation to approx 10 mL (see
Note 7).
Transfer the reduced extract to a prerinsed centrifuge tube with hexane, add 2–3 drops of
toluene, and evaporate under a gentle stream of nitrogen (temperature <30°C in both
steps 7 and 8) to approx 0.3 mL (see Note 7).
Transfer the residue to a microvial suitable for GC analysis with toluene and add 10 µL of
TePeT performance standard (PS) (see Note 4).
3.1.4. Preparation of Calibration Standard
1. Add 50 µL of the OT standard mixture (see Note 4) along with 100 µL ISTD (see Note 4)
solution into a prerinsed 15-mL centrifuge tube.
2. Add 1 mL NaOAc buffer followed by 1 mL of 1% NaB(Et)4 to this mixture and mix on a
vortex stirrer.
3. This mixture is then extracted three times with 2 mL hexane.
4. The hexane extracts are combined and reduced to approx 300 µL, and 10 µL of PS (see
Note 4) is then added.
3.2. GC–HRMS Analysis
To ensure high-quality data, rigorous quality assurance/quality control procedures
need to be in place to ensure ultimate performance of the GC–HRMS system. These
are (1) check if the instrument needs to be optimized, if necessary, daily to ensure that
it is operating at 10,000 resolving power under both static and dynamic conditions; (2)
check column resolution; (3) check ultimate sensitivity by analyzing the lowest concentration standard (see Table 1); (4) check linearity by analyzing a series of calibration standard solutions (see Table 1); (5) check sample carryover by injecting toluene
after a calibration standard solution; and (6) check stability over the course of the
analysis of real samples by analyzing calibration standard CS3 (see Table 1) every
8–10 h of operation. Although the information provided here may be adapted to other
GC–MS techniques, both high and low resolution (see Note 8), HRMS provides benefits in terms of lower detection limits and higher analyte specificity. Both GC and
HRMS conditions and parameters are provided along with details of the selected ion
monitoring (SIM) method.
3.2.1. Operating Parameters for GC
GC conditions are optimized (see Table 2) to provide maximum separation and
delivery of analyte species together with minimization of possible sample degradation
throughout the run.
Concentration of calibration standard (CS)
(µg cation/µL)
Compound
457
MBT
DBT
TBT
TeBT
MPhT
DPhT
TPhT
DCyT
TCyT
aMDL
CS1
CS2
CS3
CS4
CS5
CS6
CS7
6
11
5
57
6
7
6
6
5
28
57
26
286
30
33
29
30
27
85
171
78
857
89
100
86
91
82
226
457
208
2286
238
267
229
242
218
283
571
260
2857
297
334
286
303
272
453
914
416
4571
475
535
457
485
435
849
1714
780
8571
891
1003
857
909
816
R2
2
[R(critical) = 0.3]
0.986
0.998
0.996
0.992
0.998
0.991
0.976
0.985
0.809
MDLa
(pg)
2.4
1.8
2.4
5.9
0.13
0.53
0.50
1.4
0.87
Analysis of Organotins by GC–HRMS
Table 1
Calibration Curves for the Nine Target OT Analytes
calculation based on a 1-µL injection.
457
458
Ikonomou and Fernandez
Table 2
Operating Parameters for GC
Parameter
Value
Injection volume
Carrier gas
Injector temperature
Column temperature program:
Initial temperature
Ramp 1
Ramp 2
Final hold
1 µL sample plus 0.5 µL air
Helium at constant pressure (~60 kPa)
250°C
80°C
5°C/min for 10 min
10°C/min for 15 min
280°C for 5 min
Table 3
Operating Parameters for HRMS
Parameter
Value
GC–MS interface temperature
Ionization source temperature
Electron impact ionization energy
Detector voltage
HRMS resolution
250°C
280°C
33 eV
350 V
10,000
3.2.2. Operating Parameters for HRMS (Magnetic Sector of EBE Geometry)
The mass spectrometer should be operated in the electron impact positive (EI+)
ionization mode. OT compounds under electron impact ionization conditions fragment readily, and the molecular ions are of very low intensity. The mass spectra are
dominated by fragment ions that are characteristic for each analyte. In our previous
publication (see ref. 8), we provided details on the profiles of the fragment ions of the
analyte described in this procedure. The fragmentation is compound dependent and can
vary depending on ion source temperature, ionization energy, and instrument geometry.
The temperature of the GC–MS interface, the ion source, and the ionization conditions are optimized to provide maximum sensitivity for the target analytes (Table 3).
The aim is to establish conditions for controlled fragmentation (see Note 9) and to maximize the relative abundance of the diagnostic ions produced by each OT compound.
3.2.3. SIM Method
In the selection of SIM channels for each analyte, there is generally a trade-off
between using the most intense ions and thus maximizing sensitivity, and choosing
distinct ions (i.e., not present in any coeluting interference components) and thus minimizing interference. The ions selected for the SIM analysis of all nine OT analytes are
listed in Table 4. Two distinct isotopic fragment ions containing tin (i.e., Sn118 and
Sn120) should be monitored for each analyte as a quality assurance/quality control measure to ensure positive target analyte identification (see Subheading 3.3.1., step 3).
Analyte
459
TePeTa
DPrTb
MBT
DBT
TBT
TeBT
MPhT
DPhT
TPhT
DCyT
TCyT
194.94 m/z
Sn118(Ph)
Sn118(Ph)
Sn118(Ph)
196.94 m/z
233.05 m/z
235.05 m/z
Sn118(Pr)2Et
Sn118(Bu)(Et)2
Sn118(Bu)2H
Sn118(Bu)2H
Sn118(Bu)2H
Sn120(Pr)2(Et)
Sn120(Bu)(Et)2
Sn120(Bu)2H
Sn120(Bu)2H
Sn120(Bu)2H
231.04 m/z
233.04 m/z
261.08 m/z
263.08 m/z
Sn118(Pe)2H
Sn120(Pe)2H
Analysis of Organotins by GC–HRMS
Table 4
Summary of Positive Ions Monitored for Each OT Analyte by GC–HRMS
Sn120(Ph)
Sn120(Ph)
Sn120(Ph)
Sn118(Cy)(Et)H
Sn118(Cy)(Et)H
Sn120(Cy)(Et)H
Sn120(Cy)(Et)H
Et, ethyl; Bu, butyl; Pe, pentyl; Cy, cyclohexyl; Ph, phenyl.
standard.
bInternal standard
aPerformance
459
460
Ikonomou and Fernandez
Most ethylated OT analytes are resolved well by the chromatographic conditions
recommended here (Subheading 3.2.1.). Figure 1 shows the SIM (eight-channel) profiles of the OT standard mixture run by the GC–HRMS method. Because of similarities in boiling point and polarity to some degree, the phenyltins (F and H) coelute with
cyclohexyltins (G and I) of the same order. However, because the phenyltins produce
a predominant [Sn(C6H5)]+ (monitored at 194.94 and 196.94 m/z) that occurs at a separate m/z than [Sn(C6H11)H2]+ produced by the cyclohexyltins, these analytes can be
quantified separately. Furthermore, the cyclohexyltins produce a predominant
[Sn(C6H11)(C2H5)H]+ (monitored at 231.04 and 233.04 m/z) by EI+ MS, which is free
of interference from phenyltin fragment ions.
3.3. Data Treatment and Method Performance
Subheadings 3.3.1.–3.3.3. present relevant criteria for acceptance/rejection of GC–
HRMS OT data, along with calibration procedures and formulae for calculating the
recovery-corrected concentration of OT in water samples. Subheading 3.3.4. illustrates actual recoveries achieved for the ISTD and all nine targeted OT compounds
spiked in clean water along with recoveries for the ISTD in actual seawater samples.
3.3.1. Quality Control Criteria for GC–HRMS Data
1. The HRMS must maintain a minimum resolution of 10,000 during the entire chromatographic run.
2. Two isotopes of the specific analyte must be detected at their exact m/z. Both of the isotopic peaks must be present, and their intensities must maximize within ±2 s of one another.
3. The ratio of the two isotopic peaks (i.e., Sn118/Sn120) must be within ±20% of their expected theoretical value (i.e., 0.73 ± 0.15). If this criterion is not met, it is very likely that
the isotopic ion ratio is impacted by coeluting isobaric compounds. In such cases, the
concentration of the target analyte should be flagged as not detected because of incorrect
isotopic ratio.
4. The retention time of a specific analyte must be within 3 s to that obtained during analysis
of the authentic compounds in the calibration standards.
5. Signal-to-noise ratio of each of the isotope m/z channels must be 3 or above.
6. To ensure that all samples are analyzed under optimum instrument performance, the samples
are analyzed in a specifically designed batch. The batch composition follows this order:
a. The CS3 standard is analyzed first to ensure that the relative response factors (RRFs)
obtained are within ±20% of those established during analysis of the calibration curve
standards (i.e., CS1 to CS7, Table 1).
b. Following the CS3 analysis, 1 µL of toluene is injected to assess carryover, which
should be less than 0.4% of the peak area of the preceding CS3 (see Note 10)
c. 10 to 12 samples are analyzed.
d. Subsequently, the CS3 solution is analyzed again, and the sequence is followed as
indicated above. After 24 to 28 h of analysis, the instrument may be checked for
resolution and sensitivity before another batch of samples is loaded for analysis.
3.3.2. Calibration and LODs
To ensure that analyte concentrations fall within the linear range of instrument response for each targeted OT, a multipoint calibration curve should be established at
the beginning of the OT analysis. An example of the results of this type of multipoint
Analysis of Organotins by GC–HRMS
461
Fig. 1. SIM profiles of OT calibration standard (Subheading 3.1.4.) run by GC–HRMS. IS,
internal standard TPrT at 10.00 min; PS, performance standard TePeT at 23.15 min; A, MBT at
10.24 min; B, DBT at 14.11 min; C, MPhT at 16.00 min; D, TBT at 17.00 min; E, TeBT at
19.12 min; F and G, DPhT and DCyT, respectively, at 22.18 min; H and I, TPhT and TCyT,
respectively, at 26.55 min. Unidentified impurity at 18.65 min.
462
Ikonomou and Fernandez
calibration is provided in Table 1. Linear calibration curves are established using seven
concentrations of the OT standard mixture, each in triplicate with an additional blank
(i.e., 0 µg/µL). The coefficient of determination R2 value is given for the linear regression of each analyte together with the (Rcritical)2 for significance at a 99% confidence
level. This value is indicative of the goodness of fit of the relative response (response
of analyte divided by response of ISTD) vs concentration data to the linear function
mX + b.
In addition, minimum detection limits (MDLs) are provided for a signal-to-noise
level of 3 based on the least concentrated calibration solution. MDLs range from 0.13
pg for MPhT to 5.9 pg for TeBT and are well within the range published for other
sensitive and selective detection methods as evaluated by Aguerre et al. (3). Method
LODs are estimated at 7–29 ppt in water based on a 100-mL sample.
3.3.3. Quantitation
Quantitation of the nine OT analytes (TeBT, TBT, DBT, MBT, TPhT, DPhT,
MPhT, TCyT, and DCyT) monitored in this work is based on the method of ISTD use,
DPrT is used as the ISTD and a PS, TePeT, added following sample preparation, is
used to determine the amount of ISTD lost throughout the sample preparation process.
A single-point calibration is established using the calibration standard (prepared as
described in Subheading 3.1.4.) run at the beginning of every instrument batch (see
Note 11) resulting in RRF for all the nine analytes monitored relative to the ISTD, which
in turn has an RRF relative to the PS. RRFs are calculated as indicated Equation (1b):
[A1/A2]/RRF(1 to 2) = [C1/C2]
(1a)
RRF(1 to 2) = [C1/C2]/[A1/A2]
(1b)
This rearranges to
where A is the summed response area of both SIM isotope channels, and C is the
concentration of analyte in the solution analyzed. Subscript 1 refers to analyte and
subscript 2 to ISTD (or PS if the analyte is ISTD).
Once RRFs are determined and linearity of response is established (Subheading
3.3.2.), Eq. (2) is used to determine the percentage recovery of the ISTD, and Eq. (3)
is used to determine the recovery-corrected concentrations for each OT compound
in the sample.
Recovery (%) = [(27.7 ng × AIS)/(APS × 100 ng × RRFIS to PS)] × 100%
(2)
*C = (100 ng × Aunk/AIS × RRFunk to IS)/SW
(3)
where *C is the recovery-corrected concentration (nanograms per gram) of analyte in
the sample, A is the peak area, RRF is the relative response factor, and SW is the
sample weight (grams). Subscripts IS and unk refer to ISTD and unknown (i.e.,
sample), respectively.
All OT concentrations or amounts in this work should be based on weight of cationic species that is the convention for these compounds.
Analysis of Organotins by GC–HRMS
463
Fig. 2. Absolute recovery (not corrected for recovery of ISTD) of OT analytes from water
by in situ derivatization with NaB(Et)4 (N = 4, and error bars represent standard deviation) in
DMQ water spiked with 50 µL of OT standard mixture.
3.3.4. OT Recovered in Water Sample
The average recovery for each of the nine target analytes is between 80 and 120%,
and the total method standard deviation is less than 20% for the ISTD, first five target
OTs, and DCyT (Fig. 2). However, TCyT, DPhT, and TPhT appear to suffer from high
variability (see Note 12), which is also evident in the RRF variation (interbatch)
reported in Table 5.
The method was also applied to the determination of OT compounds in TBT-spiked
seawater samples using in a bioconcentration experiment, and the average ISTD
recovery was determined as 94% (relative standard deviation 23%) for 14 samples and
duplicates analyzed.
4. Notes
1. To eliminate the problem of high background levels because of analyte adsorption on glassware surfaces, commonly encountered in trace metal analysis, a rigorous cleaning procedure should be adopted for all routine glassware used in this work. Without acid washing
and silanization (with DCDMS) of glassware, the OT analysis may suffer from background
levels of MBT, DBT, TBT, TeBT, and MPhT. However, even when these procedures are
adopted, the background levels of MBT and DBT may still be approx 4 ng and 0.5 ng,
respectively. The levels of these two analytes in the procedural blanks may be quite consistent, in which case the samples may be easily background corrected for these two analytes.
464
Ikonomou and Fernandez
Table 5
Average Relative Response Factor (RRFs) and Relative Retention Times
(RRTs) for the Target Compounds Based on Internal Standard (N = 6)
Analyte
RRT
RRF (RSD %)
DPrT (ISTD)
MBT
DBT
MPhT
TBT
TeBT
DCyT/DPhT
TCyT/TPhT
1.00
1.02
1.41
1.60
1.70
1.91
2.22
2.66
0.15a (27)
0.36 (11)
0.48 (6)
0.51 (37)
0.49 (14)
0.18 (17)
1.23 (19)/0.61 (38)
0.90 (44)/0.63 (43)
RSD, relative standard deviation.
aRelative to performance standard TePeT.
2. Because of potential loss of calibration of volumetric flasks on heating at high temperatures, this step, as well as prior silylation with DCDMS, should be avoided and replaced
by simply air drying for this type of glassware.
3. Should preliminary analysis suggest that a sample contains OTs at levels outside the linear range of calibration, the initial sample amount may be adjusted so that the level of
these OTs may be brought back into linear range for accurate quantitation.
4. Standard solutions should be brought out of cold storage and warmed to room temperature, followed by vortexing prior to dispensing.
5. To analyze OTs by GC, tri-, di-, and monosubstituted OT salts must first be made volatile
by derivatization, which normally will involve introduction of alkyl or hydride group(s)
to the Sn complex (2). Ashby et al. (9) developed a derivatization method employing
sodium NaB(Et)4 that converts ionic organotin compounds (i.e., RnSnX(4-n)) into nonpolar
volatile derivatives (i.e., RnSn(Et)(4-n)) in situ, eliminating the problems associated with
extracting ionic compounds into an organic solvent from an aqueous matrix. This technique of OT derivatization has replaced alkylation with Grignard reagents (10–12), which
involves several steps, and is sensitive to even trace amounts of water present in the
sample or sample extract (13).
6. In the presence of excessive nontarget consumption of NaB(Et)4 as indicated by poor
ISTD or spike recoveries or obvious presence of a large amount of dissolved, colloidal, or
particulate matter, more of this reagent should be used as necessary.
7. Great care and patience must be exercised in performing this step as blowing the samples
down too fast or bringing them down too low will result in poor recoveries.
8. For a comparison between magnetic sector HRMS and quadrupole MS for the nine OTs,
see ref. 8.
9. Most EI+ mass spectra that are published or included in MS libraries are generated at an
electron energy of 70 eV (14). However, an electron energy of 33 eV should be used in
this work. These softer ionization conditions are ideal to produce a favorable fragmentation pattern for all nine OT analytes.
10. An injection of toluene is made after the CS3 solution to verify that there is minimum
carryover of analytes, that is, to check whether there are any residues in the system, including the injector, an etched syringe, GC column, GC–MS interface, and ion source.
The intensities/response of all native compounds in the toluene should be less than 0.4%
from those obtained from the analysis of the CS3 solution.
Analysis of Organotins by GC–HRMS
465
11. Percentage deviation from calibration is calculated as percentage difference between
opening calibration and either middle calibration or final (or closing) calibration throughout the run. If this percentage deviation is greater than 20%, then RRFs should be calculated based on the nearest calibration standard in the run order.
12. This high variability could most likely be improved by the incorporation of a second
ISTD that elutes closer to these analytes (retention time = 22–27 min).
Acknowledgments
We thank Tim He and Maike Fischer from DFO’s Regional Dioxin Lab (RDL) for
help with the analytical work and Fisheries and Oceans Canada and Environment
Canada for financial support.
References
1. Bancon-Montigny, C., Lespes, G., and Potin-Gautier, M. (2000) Improved routine speciation of organotin compounds in environmental samples by pulsed flame photometric
detection. J. Chromatogr. A 896, 149–158.
2. Abalos, M., Bayona, J.-M., Compañó, R., Cgranados, M., Leal, C., and Prat, M.-D. (1997)
Analytical procedures for the determination of organotin compounds in sediment and
biota: a critical review. J. Chromatogr. A 788, 1–49.
3. Aguerre, S., Lespes, G., Desauzeirs, V., and Potin-Gautier, M. (2001) Speciation of
organotins in environmental samples by SPME–GC: comparison of four specific detectors: FPD, PFPD, MIP–AES and ICP–MS. J. Anal. At. Spectrom. 16, 263–269.
4. Minganti, V., Capelli, R., and De Pellegrini, R. (1995) Evaluation of different
derivatization methods for the multi-element detection of Hg, Pb and Sn compounds by
gas chromatography–microwave induced plasma–atomic emission spectrometry in environmental samples. Fresenius J. Anal. Chem. 351, 471–477.
5. De la Calle-Guntiñas, M. B., Scerbo, R., Chiavarini, S., Quevauviller, P., and Morabito,
R. (1997) Comparison of derivatization methods for the determination of butyl- and phenyltin compounds in mussels by gas chromatography. Appl. Organomet. Chem. 11, 693–702.
6. Tao, H., Rajendran, R. B., Quetel, C. R., Nakazato, T., Tominaga, M., and Miyazaki, A.
(1999) Tin speciation in the femtogram range in open ocean seawater by gas chromatography/inductively coupled plasma mass spectrometry using a shield torch at normal
plasma conditions. Anal. Chem. 71, 4208–4215.
7. Vercauteren, J., Pérès, C., Devos, C., Sandra, P., Vanhaecke, F., and Moens, L. (2001)
Stir bar sorptive extraction for the determination of ppq-level traces of organotin compounds in environmental samples with thermal desorption-capillary gas chromatography–
ICP mass spectrometry. Anal. Chem. 73, 1509–1514.
8. Ikonomou, M. G., Fernandez, M. P., He, T., and Cullon, D. (2002) Gas chromatography–
high-resolution mass spectrometry based method for the simultaneous determination of
nine organotin compounds in water, sediment and tissue. J. Chromatogr. A 975, 319–333.
9. Ashby, J., Clark, S., and Craig, P. J. (1988) Methods for the production of volatile organometallic derivatives for application to the analysis of environmental samples. J. Anal.
At. Spectrom. 3, 735–736.
10. Arnold, C. G., Berg, M., Müller, S. R., Dommann, U., and Schwarzenbach, R. P. (1998)
Determination of organotin compounds in water, sediments, and sewage sludge using
perdeuterated internal standards, accelerated solvent extraction, and large-volume-injection GC/MS. Anal. Chem. 70, 3094–3101.
466
Ikonomou and Fernandez
11. Moens, L., Smaele, T. D., Dams, R., Van den Broeck, P., and Sandra, P. (1997) Sensitive,
simultaneous determination of organomercury, -lead, and -tin compounds with headspace
solid phase microextraction capillary gas chromatography combined with inductively
coupled plasma mass spectrometry. Anal. Chem. 69, 1604–1611.
12. Ceulemans, M., Witte, C., Lobinski, R., and Adams, F. C. (1994) Simplified sample
preparation for GC speciation analysis of organotin in marine biomaterials. Appl.
Organomet. Chem. 8, 451–461.
13. Michel, P. and Averty, B. (1991) Tributyltin analysis in seawater by GC-FPD after direct aqueous-phase ethylation using sodium tetraethylborate. Appl. Organomet. Chem.
5, 393–397.
14. Mosi, A. A. and Eigendorf, G. K. (1998) Current mass spectrometric methods in organic
chemistry. Curr. Organ. Chem. 2, 145–172.
Triazine in Water
467
34
Determination of Triazine Herbicides and Degradation
Products in Water by Solid-Phase Extraction
and Chromatographic Techniques Coupled
With Mass Spectrometry
Hassan Sabik and Roger Jeannot
Summary
At least 29 triazines and 36 degradation products have been reported in the literature.
For many reasons, no single method enables the simultaneous extraction and analysis of
all of these compounds. Three methods are described for monitoring triazines and degradation products in filtered and raw water (0.5–1 L). Analytes are extracted from water
samples by solid-phase extraction using cartridges packed with C18 bonded silica (Isolute
Triazine) or graphitized carbon black (Carbopack B), and the eluate is analyzed by gas
chromatography–mass spectrometry equipped with a large-volume injection system (LVI/
GC–MS) and liquid chromatography with mass spectrometry and tandem mass spectrometry equipped with an atmospheric pressure chemical ionization source (LC/APCI–MS,
LC–MS/MS/APCI). Tests show that most (>60%) of the recoveries are satisfactory. They
are similar for all target pesticides for given types of water (filtered or raw water), sorbents, and chromatographic techniques. The coefficient of variation is less than 10% for
most of the pesticides, regardless of the method used, and detection limits range from
0.2–3.7 ng/L and 2–5 ng/L for LVI/GC–MS and LC–MS/MS/APCI, respectively.
Key Words: C18; Carbopack B; degradation products; environmental analysis; gas
and liquid chromatography; mass spectrometry; large-volume injection; solid-phase
extraction; tandem mass spectrometry; triazines; water analysis.
1. Introduction
There is growing concern about both triazine herbicides and their degradation products because of their toxicity and their increased use and occurrence in natural waters
(1–3). Some triazine degradation products are as toxic as, or even more toxic than,
their parent compounds (2–4). At least 29 triazines and 36 degradation products have
been reported in the literature (4). Unfortunately, no single method enables the simultaneous extraction and analysis of all of these compounds (5–22). In this chapter, we
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
467
468
Sabik and Jeannot
describe three methods that can be used to monitor triazines and degradation products
in filtered and raw water (0.5–1 L). All begin with solid-phase extraction (SPE) using
cartridges packed with either C18-bonded silica (Isolute Triazine) or graphitized carbon black (Carbopack B). The analytical methods used to determine the pesticides are
gas chromatography–mass spectrometry equipped with a large-volume injection system (GC/LVI–MS), liquid chromatography with mass spectrometry and with tandem
mass spectrometry equipped with an atmospheric pressure chemical ionization (LC–
MS/APCI and LC–MS/MS/APCI, respectively) ion source.
2. Materials
1. Vacuum manifold.
2. 6.5 × 1.4 cm internal diameter (id) polypropylene cartridges packed with 1 g C18-bonded
silica (Isolute Triazine) and a depth filter (IST Ltd, U.K.).
3. 6.5 × 1.4 cm id polypropylene cartridges packed with 500 mg graphitized carbon black
(120–400 mesh) (Supelco).
4. Closed cartridges packed with 2.5 g anhydrous sodium sulfate (IST Ltd, U.K.).
5. Polytetrafluoroethylene filters (0.45 µm, 47-mm id) (Millipore).
6. Gas chromatograph equipped with a split/splitless programming temperature injector
working in the LVI mode and coupled with a mass spectrometer (Varian; Thermo).
7. Electron ionization (EI) ion source.
8. Capillary columns (5% phenyl/95% methylsilicone; 30 m × 0.25 mm id, 0.25-µm coating
thickness) (Supelco).
9. Deactivated capillary guard column (5 m × 0.53 mm id) (Supelco).
10. Liquid chromatograph coupled with a quadrupole mass spectrometer or an ion trap tandem mass spectrometer (Thermo).
11. APCI ion source.
12. LC system equipped with a quaternary pump and an autosampler.
13. LC columns filled with a C18 silica phase (25 cm × 4.6 mm id, Hypersil ODS 2 column
packed with 5-µm particles) or other phases providing similar separation (Thermo).
14. Reagents: acetone, acetonitrile, dichloromethane (DCM), methanol (MeOH) (distilledin-glass grade or residue pesticide quality) and Milli-Q water.
15. Pesticide and deuterated standards (>95% pure).
3. Methods
The three methods described here are (1) SPE using Carbopack B cartridges (protocol 1) followed by GC/LVI–MS), (2) SPE using Isolute Triazine cartridges (protocol
2) followed by GC/LVI–MS, and (3) SPE using Isolute Triazine cartridges (protocol
3) followed by LC–MS/APCI and LC–MS/MS/APCI.
3.1. Sample Collection and Preservation
The water samples are collected in 1-L amber glass containers (see Note 1) and
stored at 4°C until extraction. Sequential extraction should be done within 48 h to
avoid any transformation in the structure of the target analytes.
3.2. Solid-Phase Extraction
SPE is done to extract triazines and degradation products from filtered or unfiltered
surface water (suspended particulate matter = 2–60 mg/L) using cartridges packed
Triazine in Water
469
with various sorbents. Protocols 1 and 2 are used prior to GC/LVI–MS analysis, and
protocol 3 is used prior to LC–MS/APCI and LC–MS/MS/APCI. Protocol 2 is a simultaneous filtration-and-extraction technique. The following procedure describes the
steps used in the three protocols. Table 1 gives specifications for each individual protocol.
1. Filter surface water sample (protocols 1 and 3) through a polytetrafluoroethylene filter
(0.45 µm, 47-mm id) to eliminate suspended particulate matter (see Note 2).
2. Condition the cartridges by rinsing with solvents in the order indicated under “Conditioning” in Table 1 (see Notes 3 and 4).
3. Load the sample by attaching a connector to the top of the cartridge. The other end of the
connector should be fitted with a 1/8-in Teflon tube with a stainless steel weight at its
end. Feed the weighted end of the Teflon tube into the sample container until it touches
the bottom. Place the cartridge on the vacuum manifold.
4. Pass the sample through the cartridges: Turn on the vacuum pump to draw the sample
through the cartridge. This takes approx 50 min (see flow rates in Table 1) and can be
done with either a water or a vacuum pump.
5. Rinse the cartridge with water: Add 6 mL of Milli-Q water to the cartridges and pump for
15 min to remove any residual water (see Note 5). Discard washes.
6. Protocols 1 and 2 only: Place a closed cartridge filled with 2.5 g anhydrous sodium sulfate below the rinsed cartridge.
7. Protocol 1 only: Pass 1 mL methanol through the cartridge system (Carbopack–sodium
sulfate) and discard this fraction.
8. Elute the cartridge system with selected eluent (Table 1) at a rate of 1 mL/min. Collect
the eluate in a 15-mL conical test tube, then evaporate most of the solvent with a nitrogen
stream at 25°C. Add 100 µL (20 µg) of the internal standard solution (atrazine-d5; see
Note 6) to the extract, then add enough of the appropriate solvent to reach the final volume (Table 1) for chromatographic analysis.
3.3. GC and LC Coupled With MS
3.3.1. GC/LVI–MS
Sample extracts from SPE protocols 1 and 2 are analyzed using a gas chromatograph coupled with an ion trap mass spectrometer (see Note 7) equipped with a split/
splitless programming temperature injector working in the LVI mode (see Note 8).
Figure 1 shows a chromatogram obtained by injecting 40 µL of an extract of 1 L of
water from a tributary of the Loire River (following SPE) into a GC/LVI–MS. The
analysis steps are preparation of the calibration curve, chromatographic analysis, and
identification and quantification of analytes.
1. Set the initial column temperature at 40°C for 5 min, increase it to 300°C at a rate of 5°C/
min, and hold it steady at this temperature for 5 min.
2. Set the initial injector temperature at 40°C for 1.5 min (see Note 9), increase it to 300°C
at a rate of 180°C/min, and hold it steady at this temperature for 62 min.
3. Very slowly (2 µL/s, see Note 10), inject 20–40 µL of the standard solutions (0.02–2 mg/
L) and the extracts obtained from SPE protocols 1 and 2. Both the standard solutions and
the extracts should include the internal standard at a concentration of 0.20 mg/L DCM.
The flow rate of the carrier gas (helium) is set at 1 mL/min for a split flow of 50 mL/min.
The split/splitless valve is operated in split mode from 0 to 1.5 min, splitless mode from
1.5 min to 3 min, and split mode after 3 min.
470
Table 1
Specifications for the Three SPE Protocols
470
Protocol 1
Protocol 2
Protocol 3
Flow rate
Eluent
GCB Carbopack B
1L
Yes
3 × 6 mL DCM
6 mL MeOH
6 mL Milli-Q water
20 mL/min
15 mL DCM
C18 Isolute Triazine
0.5 L
Yes
6 mL acetone
10 mL Milli-Q water
NA
10 mL/min
2 × 2 mL MeOH
Final volume
1 mL DCM
C18 Isolute Triazine
0.5 L
Not necessary
3 × 6 mL DCM
6 mL acetone
6 mL Milli-Q water
10 mL/min
15 mL DCM/acetone
(80:20 v/v)
0.250 mL DCM
Sorbent
Sample volume
Filtration
Conditioning
Solvent 1
Solvent 2
Solvent 3
0.5 mL MeOH/water
(50:50 v/v)
GCB, graphitized carbon black; NA, not applicable.
Sabik and Jeannot
Triazine in Water
471
Fig. 1. A chromatogram obtained by injecting 40 µL into a GC/LVI–MS: Ion chromatograms
of an extract of 1 L water from a tributary of the Loire River after SPE (Carbopack B, 120-400
mesh). Peaks: 1, desethyl-atrazine (17 ng/L); 2, simazine (<1 ng/L); 3, atrazine (96 ng/L); 4,
terbuthylazine (<1 ng/L); IS, atrazine-d5 (206 ng/L). Peak for other compound: 5, alachlor (10 ng/L).
4. Perform the mass spectrometric analysis with EI interface in full-scan mode from 47 U to
450 U.
5. Identify each peak by its mass spectrum and retention time (see Note 11) and extract the
signal at specific m/z.
6. Quantify the analyte by measuring the peak areas (or the peak area/internal standard peak
area ratio) of the sample extracts and comparing them to those of the standard solutions.
7. The m/z used for the quantification of the target compounds are given in Table 2.
8. Calculation: The concentration C (micrograms per liter) of the target analyte is calculated
using the following equation:
C = CeVf/Vw
where Ce is the concentration in the final extract in micrograms per milliliter, Vf is the
final volume of extraction solvent in milliliters, and Vw is the sample volume in liters.
3.3.2. LC–MS/APCI and LC–MS/MS/APCI
Sample extracts from SPE protocol 3 are analyzed using a liquid chromatograph
coupled with a quadrupole mass spectrometer (see Note 12) or an ion trap mass spectrometer running in MS/MS mode (see Note 13) equipped with an injection valve
(20–100-µL injection volume), a gradient pump, and an APCI ion source (see Note
14). Figures 2 and 3 show LC/APCI plus full-scan MS/MS chromatograms of a stan-
472
Sabik and Jeannot
Table 2
Selected Ions (m/z) Used for Triazine Quantification by GC/LVI–MS and LC–MS/APCI:
Examples of Transition Ions for the Compounds Analyzed by LC–MS/MS/APCI Using
Triple Quadrupole
Compound
Ametryn
Atraton
Atrazine
Cyanazine
Desethyl-atrazine
Desmetryna
Metribuzin
Desipropyl-atrazine
Hydroxyatrazinea
Hydroxysimazinea
Prometon
Prometryn
Propazine
Simazine
Terbuthylazine
Selected ions (m/z)
Precursor ion (m/z)
GC/LVI–MS
LC–MS/APCI
212, 227
169, 196, 211
173, 200, 215
225, 240
172, 174, 187
NA
144, 182, 214
145, 158, 173
NA
NA
168, 210, 225
184, 226, 241
172, 214, 229
173, 186, 201
NA
228
212
216
241
188
NA
215
174
NA
NA
226
242
230
202
230
Daughter ions (m/z)
LC–MS/MS/APCI
228
NA
216
241
188
214
215
174
198
184
NA
NA
230
202
230
186
NA
174
214
146
172
187
104
156
114
NA
NA
188
132
174
NA, not available.
quantified.
aNot
dard solution and a detailed signal on each ion, respectively. The analysis steps are
preparation of the calibration curve, chromatographic analysis, and identification and
quantification of analytes.
3.3.2.1. LC–MS/APCI
1. Set the flow rate of the mobile phase (85% water/15% acetonitrile) at 1 mL/min.
2. Use an acetonitrile/water binary gradient of 15/85 to 60/40 in 50 min.
3. Inject 20–50 µL of the standard solutions (25, 50, 130, 260, 520, 1040, 2600 µg/L) and
the extracts obtained from SPE protocol 3.
4. Set the APCI ion source in the positive ion mode (see Note 15).
5. Perform the MS analysis in full-scan mode from 130 to 450 U (see Note 16).
6. Identify each peak by its mass spectrum and retention time (see Note 17) and extract the
signal at specific m/z.
7. Quantify the analyte by measuring the peak areas (or the sample area/internal standard
area ratio) of the sample extracts and comparing them to those of standard solutions.
8. The m/z used for the quantification is given in Table 2.
9. Calculation: The concentration C (micrograms per liter) of target analyte is calculated
using the following equation:
C = CeVf/Vw
Triazine in Water
473
Fig. 2. LC/APCI plus full-scan MS/MS chromatogram of a standard solution (1 µg/mL of
each compound in methanol) scanning from m/z 50 to approx 10 u above the precursor ions u.
Peak assignments for triazines: 1, desipropyl-atrazine; 2, desethyl-atrazine; 4, simazine; 5, atrazine; 9, terbuthylazine. Peak assignments for other compounds: 3, carbendazim; 6, isoproturon; 7
and 8, triadimenol; 10, tebuconazole; 11, flusilazole; 12, penconazole; 13 and 14, propiconazole.
where Ce is the concentration in the final extract in micrograms per milliliter, Vf is the
final volume of extraction solvent in milliliters, and Vw is the sample volume in liters.
3.3.2.2. LC–MS/MS/APCI
1. Set the flow rate of the mobile phase (85% water/15% acetonitrile) at 1 mL/min.
2. Use an acetonitrile/water binary gradient of 15/85 to 60/40 in 50 min.
3. Inject 20–50 µL of the standard solutions (1, 5, 10, 25, 50, 100 µg/L) and the extracts
obtained from SPE protocol 3.
4. Set the APCI ion source in the positive ion mode (see Note 15).
5. Perform the MS analysis in MS/MS by (1) selecting the protonated ion of each compound
for each time segment of the chromatographic separation; (2) setting, in the ion trap, the
collision energies of the protonated ions with helium producing a mass spectra in MS/
MS; and (3) analyzing the resulting daughter ions by scanning m/z between 50 and 10 u
above the molecular mass of each compound (Table 3).
6. Identify each peak by its mass spectrum in MS/MS and retention time (see Note 18) and
extract the signal of daughter ions at specific m/z (Table 3).
474
474
Sabik and Jeannot
Fig. 3. LC/APCI plus MS/MS chromatogram of a standard solution (1 µg/mL of each compound in methanol solution), detailed signal on
each ion. Peak assignments for triazines: 1, desipropyl-atrazine; 2, desethyl-atrazine; 4, simazine; 5, atrazine; 9, terbuthylazine. Peak assigments
for other compounds: 3, carbendazim; 6, isoproturon; 7 and 8, triadimenol; 10, tebuconazole; 11, flusilazole; 12, penconazole; 13 and 14,
propiconazole.
Triazine in Water
Table 3
General Conditions Used for LC–MS/MS/APCI Analysis Using Ion Trap Mass Spectrometer
Segment
475
1
2
3
4
5
Time (min)
0.0–13.18
13.20–17.48
17.50–31.10
31.20–37.36
37.40–43.70
Protonated
parent ion
selected m/z
Collision voltage in
ion trap detector
(V)
174
188
202
216
230
230
0.80
0.80
0.90
0.90
0.75
0.75
Compounds
Desipropyl-atrazine
Desethyl-atrazine
Simazine
Atrazine
Propazine
Terbuthylazine
MS/MS fullscan interval
Retention time
(min)
50–84
50–98
55–212
60–226
60–240
60–240
10.44
16.01
27.22
33.69
39.23
40.06
475
476
Sabik and Jeannot
Table 4
Detection Limits (DLs) and Mean Recovery Obtained for Target Pesticides
in Surface Water Using the Proposed Methods
Pesticide
Ametryn
Atraton
Atrazine
Cyanazine
Desethyl-atrazine
Desipropyl-atrazine
Metribuzin
Prometon
Prometryn
Propazine
Simazine
Mean recovery
(%) in surface water (n = 3)
DL (ng/L)
Method 1
Method 2
Method 3
Method 1
Method 2
Method 3
1.6
1.1
1.5
3.7
1.8
2
1.5
0.6
0.9
0.7
2
0.6
NA
0.2
0.8
0.3
0.3
NA
NA
0.8
0.2
0.2
NA
NA
2
NA
3
5
NA
NA
NA
2
3
90 ± 11
87 ± 3
86 ± 2
95 ± 7
71 ± 4
78 ± 2
78 ± 8
91 ± 2
58 ± 2
84 ± 2
95 ± 8
105 ± 2
NA
80 ± 3
125 ± 6
55 ± 3
29 ± 2
NA
NA
97 ± 2
96 ± 6
97 ± 2
NA
NA
92 ± 4
NA
60 ± 3
35 ± 4
NA
NA
NA
96 ± 7
98 ± 4
NA, not available.
Method 1: SPE using Carbopack B (120- to 400-mesh) cartridges followed by GC/LVI–MS. 1-L
sample volume; 1-mL final volume.
Method 2: SPE using C18 Isolute Triazine cartridges followed by GC/LVI–MS. 0.5-L sample volume; 0.25-mL final volume.
Method 3: SPE using C18 Isolute Triazine cartridges followed by LC–MS/APCI and LC–MS/MS/
APCI. 0.5-L sample volume; 0.5-mL final volume.
7. Quantify the analyte by measuring the peak areas (or the sample area/internal standard
area ratio) of the sample extracts and comparing them to those of standard solutions.
8. The m/z used for the quantification is given in Table 3.
9. Calculation: The concentration C (micrograms per liter) of target analyte is calculated
using the following equation:
C = CeVf/Vw
where Ce is the concentration in the final extract in micrograms per milliliter, Vf is the
final volume of extraction solvent in milliliters, and Vw is the sample volume in liters.
3.4. Quality Control
The compounds targeted in each protocol are given in Table 4.
1. Method blanks are analyzed after every five samples using a volume of 0.5 L of Milli-Q
water, and blank samples are extracted using the same protocol as for surface water
samples. No traces of target chemicals are detected in the blanks, and there is no interference except for propazine (0.9 ng/L), which is present in the internal standard solution
(atrazine-d5) at a ratio of 1%.
2. Recovery is measured by extracting and analyzing target pesticides previously spiked at
0.05- to 0.1- ppb levels from 0.5 to 1 L of surface water samples using the proposed
methods (Table 4). Overall percentage recoveries are satisfactory for all target pesticides
Triazine in Water
477
(>60%) except desisopropyl-atrazine (more polar). The coefficient of variation is below
10% for most of the pesticides regardless of the method used.
3. Detection limits are determined for each analyte at a concentration providing a signal-tonoise ratio of 3 (Table 4). Detection limits ranged from 0.2 to 3.7 ng/L and 2 to 5 ng/L for
GC/LVI–MS and LC–MS/MS/APCI, respectively.
4. Notes
1. The analytical samples are taken in amber glass bottles certified free of organic compound residues or in glass bottles wrapped in aluminum foil and previously washed with
a detergent solution, rinsed with distilled water, and cleaned with petroleum ether and
acetone. A blank should be used for verifying the efficiency of the bottle washing.
2. The sampling site must be homogeneous and representative. An all-Teflon pneumatic
pump and Teflon tubing should be used when sampling surface water.
3. Carbopack B packing has positive charges on its surface that enable it to behave as both a
reversed-phase and an anion exchanger sorbent. To activate the anion exchange sites, the
cartridge must be conditioned with an acidic reagent. We do not recommend this step for
routine analysis when using GC–MS because the acidic reagent remains in the eluate,
contaminating the liner and the capillary precolumn or column.
4. The cartridge must not be allowed to go dry at any time during the conditioning and
extraction steps.
5. Increase drying time (30 min) if there is any residual water in the eluate.
6. Various deuterated internal standards can be used (e.g., simazine-d6 or terbuthylazine-d5).
7. If a quadrupole mass spectrometer in selected ion monitoring mode is used instead of an
ion trap spectrometer, similar performance can be obtained using three m/z ions (one
identifier and two qualifiers).
8. Various LVI devices are available (e.g., on column and septum-equipped programmable
injectors). LVI are devices that can be retrofitted to any GC and replace conventional
split/splitless injectors.
9. The injection temperature should be 10–15°C above the vaporization temperature of the
solvent used for injection.
10. The sample is injected very slowly with the injector temperature set a few degrees below
the boiling point of the solvent. The solvent is vented at the same time as it is injected
through the injector split valve.
11. Identification criteria in GC/LVI–MS: retention time (does not differ from the peak measured in the external standard by less than ±0.2%) plus mass spectrum [the most sensitive
diagnostic ion is present, the two selected diagnostic ions do not deviate by more than ±(0.1
× Ist + 10%)] in which Ist is the relative intensity of the diagnostic ions in the external standard.
12. An ion trap mass spectrometer can be used instead of a quadrupole mass spectrometer.
13. A triple-quadrupole mass spectrometer can be used instead of the ion trap mass spectrometer. This technique using time-scheduled selected reaction monitoring mode allows
obtaining similar results to ion trap mass spectrometry in MS/MS mode.
14. An electrospray ionization ion source in positive mode could be used in place of the
APCI. Generally, both are appropriate for nonpolar and low-polar compounds.
Electrospray ionization is preferred for more polar compounds.
15. APCI conditions: 400°C vaporizer temperature; 225°C transfer capillary temperature; 5µA corona discharge intensity; 0.6-MPa sheath gas pressure; 10-L/min auxiliary gas flow
rate; 5-V octapole voltage. Positive ionization mode is used for these compounds produced in APCI protonated ions.
478
Sabik and Jeannot
16. MS detection could be done in selected ion monitoring mode to improve the quantification limit. However, in this detection mode, the specificity is decreased.
17. Identification criteria in LC–MS/APCI: retention time, which does not differ from the
peak measured in the external standard by less than ±0.2%; mass spectra, for which the
protonated ion must be present in the sample and in the external standard.
18. Identification criteria in LC–MS/MS/APCI: retention time, which does not differ from
the peak measured in the external standard by less than ±0.2%; mass spectra, for which
the precursor ion and the most abundant daughter ion must be present.
References
1. Hapeman, C. J., Bilboulian, S., Anderson, B. G., and Torrents, A. (1998) Structural influences of low molecular weight dissolved organic carbon mimics on the photolytic fate of
atrazine. Environ. Toxicol. Chem. 17, 975–981.
2. Kolpin, D. W., Thurman, E. M., and Linhart, S. M. (1998) The environmental occurrence
of herbicides—the importance of degradates in ground water. Arch. Environ. Contam.
Toxicol. 35, 385–390.
3. Thurman, E. M., Mills, M. S., Meyer, M. T., Zimmerman, L. R., Perry, C. A., and Goolsby,
D. A. (1994) Formation and transport of deethylatrazine and deisopropylatrazine in surface water. Environ. Sci. Technol. 28, 2267–2277.
4. Sabik, H., Jeannot, R., and Rondeau, B. (2000) Multiresidue methods using solid-phase
extraction techniques for monitoring priority pesticides, including triazines and degradation products, in ground and surface waters. J. Chromatogr. A 885, 217–236.
5. Ashton, F. and Klingman, G. (eds.). (1982) Weed Science, Principles and Practices. Wiley,
London.
6. Cai, Z., Ramanujam, V. M. S., Gross, M. L., Monson, S. J., Cassada, D. A., and Spalding,
R. F. (1994) Liquid–solid extraction and fast atom bombardment high-resolution mass
spectrometry for the determination of hydroxyatrazine in water at low-ppt levels. Anal.
Chem. 66, 4202–4209.
7. Crescenzi, C., DiCorcia, A., Passariello, G., Samperi, R., and Carou, M. I. T. (1996) Evaluation of two new examples of graphitized carbon blacks for use in solid-phase extraction
cartridges. J. Chromatogr. A 733, 41–55.
8. Ferrer, I., Barceló, D., and Thurman, E. M. (1999) Doubled-disk solid-phase extraction—
simultaneous cleanup and trace enrichment of herbicides and metabolites from environmental samples. Anal. Chem. 71, 1009–1015.
9. Forcada, M., Beltran, J., Lopez, F. J., and Hernandez, H. (2000) Multiresidue procedures
for determination of triazine and organophosphorus pesticides in water by use of largevolume PTV injection in gas chromatography. Chromatographia 51, 362–368.
10. Geerdnik, R. B., Kooistra-Sijpersma, A., Tiesnitsch, J., Kienhuis, P. G. M., and Brinkman
U. A. T. (1999) Determination of polar pesticides with atmospheric pressure chemical
ionization mass spectrometry-mass spectrometry using methanol and/or acetonitrile for
solid-phase desorption and gradient liquid chromatography. J. Chromatogr. A 863, 147–155.
11. Jeannot, R., Sabik, H., Sauvard, E., and Genin, E. (2000) Application of liquid chromatography with mass spectrometry combined with photodiode array detection and tandem mass
spectrometry for monitoring pesticides in surface waters. J. Chromatogr. A 879, 51–71.
12. Jeannot, R., Sabik, H., Amalric, L., Sauvard, E., Proulx, S., and Rondeau B. (2001)
Ultra-trace analysis of pesticides by solid-phase extraction of surface water with
Carbopack B cartridges, combined with large-volume injection in gas chromatography.
Chromatographia 54, 236–240.
Triazine in Water
479
13. Koskinen, W. C. and Barber, B. L. (1997) A novel approach using solid phase extraction
disks for extraction of pesticides from water. J. Environ. Qual. 26, 558–560.
14. Kumazawa, T. and Suzuki, O. (2000) Separation methods for amino-possessing pesticides
in biological samples. J. Chromatogr. A 747, 241–254.
15. Lerch, R. N. and Donald, W. W. (1994) Analysis of hydroxylated atrazine degradation
products in water using solid-phase extraction and high performance liquid chromatography. J. Agric. Food Chem. 42, 922–927.
16. LiS ka, I. and Slobodník, J. (1996) Comparison of gas and liquid chromatography for
analysing polar pesticides in water samples. J. Chromatogr. A 733, 235–258.
17. Loos, R. and Niessner, R. (1999) Analysis of atrazine, terbutylazine and their Ndealkylated chloro and hydroxyl metabolites by solid-phase extraction and gas chromatography–mass spectrometry and capillary electrophresis–ultraviolet detection. J.
Chromatogr. A 835, 217–229.
18. Magnuson, M. L., Speth, T. F., and Kelty, C. A. (2000) Degradation of interfering triazine
degradation products by gas chromatography-ion trap mass spectrometry. J. Chromatogr.
A 868, 115–119.
19. Molina, C., Durand, G., and Barceló, D. (1995) Trace determination of herbicides in estuarine waters by liquid chromatography-high-flow pneumatically assisted electrospray
mass spectrometry. J. Chromatogr. A 712, 113–122.
20. Sabik, H., Rondeau, B., Gagnon, P., Jeannot, R., and Dohrendorf, K. (2003) Simultaneous
filtration and solid-phase extraction combined with large-volume injection in GC/MS for
ultratrace analysis of polar pesticides in surface water. Int. J. Environ. Anal. Chem. 83,
457–468.
21. Spliid, N. H. and Køppen, B. (1996) Determination of polar pesticides in ground water
using liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization. J. Chromatogr. A 736, 105–114.
22. Thurman, E. M. and Mills, M. S. (eds.). (1998) Solid-Phase Extraction: Principles and
Practices. Wiley Interscience, New York.
∨
Optical Immunosensors for Pesticides
481
35
An Optical Immunosensor for Pesticide Determination
in Natural Waters
Sara Rodríguez-Mozaz, Maria J. López de Alda, and Damia Barceló
Summary
The river analyzer (RIANA) is an optical immunosensor able to determine different
types of organic pollutants in water samples. Interaction between fluorescently labeled
antibody and analyte takes place on a solid–liquid interface and is detected by measuring
the fluorescence. The RIANA integrates the optical part with a fluidics part in a compact
unit, which is coupled to an autosampler, allowing the performance of automatic measurements within 15 min.
In this chapter, the use protocol for the sensor is described, and guidelines about
experiment performance are provided. Up to three different analytes (in this case, the
pesticides atrazine and isoproturon and the natural estrogen estrone) can be detected
simultaneously. This multianalyte configuration allows reduction in time of analysis and
in volume of sample and other reagents required. Different aspects, such as assay performance, cross-reactivity, matrix effects, or validation, are also considered.
Key Words: Environmental monitoring; estrogens; immunosensor; multianalyte;
pesticides; water.
1. Introduction
Monitoring of pesticides and other relevant pollutants in natural waters is commonly required for environmental control. To accomplish this requirement, new analytical tools able to provide fast and reliable data are demanded. In this sense,
biosensors seem to be appropriate. In general, biosensors for environmental applications do not compete with official analytical methods. Instead, they are mostly designed for the screening of samples by both regulatory authorities and industry. These
samples can further be sent to laboratories, if necessary, for detailed chemical analysis,
thus reducing the costs of monitoring programs (1). The river analyzer (RIANA) biosensor can be applied to the determination of different pesticides in natural waters (2–4).
RIANA is an optical immunosensor based on the use of antibodies as specific recognizing agents and an optical transducer able to convert the recognition of the analyte
in a readable signal. Interaction between fluorescently labeled antibody and analyte
From: Methods in Biotechnology, Vol. 19, Pesticide Protocols
Edited by: J. L. Martínez Vidal and A. Garrido Frenich © Humana Press Inc., Totowa, NJ
481
482
Rodríguez-Mozaz, López de Alda, and Barceló
Fig. 1. Scheme of the immunosensor RIANA. The FIA system equipped with a six-port valve
and a 1-mL syringe pump delivers the buffer solution, the sample, or the regeneration solutions
to the flow cell. The transducer, a 1.5-mm thick surface polished sheet glass, is mounted on the
flow cell and is sealed with an O-ring. The excitation light consists of a He-Ne laser. The collected fluorescent light is filtered and detected by photodiodes (PDs). PC, personal computer.
(which acts as an antigen) takes place on a solid–liquid interface and is detected by
measuring the fluorescence. The device (scheme shown in Fig. 1) consists of a flow
injection analysis system (FIA) with a six-way distribution valve equipped with a 1mL
syringe pump connected through Teflon tubing to a flow cell. The transducer is
mounted in this flow cell and sealed by an O-ring. Light from a collimated and modulated He-Ne laser source (633 nm, 7 mW) is directly coupled and guided through the
length of the transducer by total internal reflection. An evanescent field is produced at
each reflection spot and penetrates a few hundreds of nanometers into the external
medium. This field causes the excitation of fluorescently labeled antibodies locally
and specifically bound to the analyte derivatives. The fluorescence light is collected
through optic fibers, filtered, and detected by photodiodes using lock-in detection.
Automatic measurements are carried out with the system within 15 min, including the
regeneration step. This system setup has been described previously (5).
On the other hand, RIANA also enables the simultaneous determination of several
pollutants in the same sample. This feature can represent an interesting tool in environmental monitoring and screening because it allows a reduction in both time and
volume of sample and other reagents required. This chapter describes the application
of the RIANA immunosensor, in multianalyte configuration, to the simultaneous
determination of two pesticides (atrazine and isoproturon) and a natural estrogen of
growing environmental concern (estrone).
Optical Immunosensors for Pesticides
483
2. Materials
2.1. Chemicals
1.
2.
3.
4.
5.
6.
HPLC-grade methanol.
Pro analysis ethanol.
Ovalbumin (OVA) (e.g., Sigma; Deisenhofen, Germany).
Pesticide standards atrazine and isoproturon (e.g., Riedel-de-Haen, Seelze, Germany).
Estrone standard (e.g., Sigma-Aldrich; Deisenhofen, Germany).
Lyophilized antiestrone, antiisoproturon, and antiatrazine antibodies and the corresponding analyte derivatives used were kindly supplied by Dr. Ram Abuknesha (King’s College, London, UK).
2.2. Working Solutions
1. Phosphate-buffered saline (PBS): 150 mM NaCl, 50 mM KH2PO4 adjusted to pH 7.4 with
2 M KOH in bidistilled water.
2. Regeneration solution: 0.5% sodium dodecyl sulfate (SDS) adjusted with an HCl solution
(5 N) to pH 1.9.
3. 75:25 (v/v) Ethanol/bidistilled water rinsing solution.
4. Stock standard solutions: Stock standard solutions for each analyte are prepared in methanol at 1000 mg/L by dissolving 10 mg standard in 10 mL methanol. The solutions are kept
at 20°C.
3. Methods
3.1. Preparation of the Transducer
1. As a solid-phase immunoassay, inmobilize the analyte derivative on a clean glass slide
(transducer) following the protocol described by Barzen et al. (6).
2. Briefly, clean glass interference layers (58 × 10 × 1.5 mm with 45° bevel on short side) by
immersion in a freshly prepared hot mixture of concentrated piranha solution for 30 min
and afterward rinse with water.
3. Achieve the silanization of the surface by treatment for 1 h with 30 µL of 3glycidoxypropyltrimethoxysilanxysilane. Each aminodextran–hapten–conjugate (atrazine, estrone, and isoproturon) is then placed in the corresponding hole (~1-mm diameter)
of a metal mask placed on top of the transducer surface. Conjugates from analyte derivative and polymer are thus coupled to the activated transducer surface in separated areas.
3.2. Preparation of Calibration
1. Prepare water standard solutions at various concentrations by appropriate dilution of the
stock solutions with PBS. Final aqueous solutions should not contain more than 0.1%
methanol.
2. Choose standard concentrations to match the estimated concentrations of the analytes in
unknown samples.
3. Keep water standard solutions at 4°C up to 15 d.
3.3. Preparation of Antibodies Solution
1. Lyophilized anti-estrone, anti-isoproturon, and anti-atrazine antibodies (labeled with the
fluorescent dye Cy5.5) are reconstituted with phosphate buffer solution before their use,
giving a final mixture solution of the three antibodies (see Note 1). Concentrations obtained for anti-estrone, anti-isoproturon, and anti-atrazine are 3.5, 3.3, and 0.5 µg/mL,
respectively.
484
Rodríguez-Mozaz, López de Alda, and Barceló
2. The antibody solution must be strongly buffered since analyte–antibody binding is very
sensitive to pH (see Note 2).
3. The antibody solution as well as the final incubated solution need to have a pH of approx 7.4.
4. Add the background protein OVA to reduce the nonspecific binding of proteins to the
transducer surface. Therefore, prepare the antibody solution so that the OVA concentration is 2000 µg/mL (see Note 2).
5. Once the antibody solution is combined with the analyte solution, the final concentration
of the OVA is about 200 µg/mL.
6. Final concentrations of the antibodies are 0.35, 0.33, and 0.05 µg/mL for antiestrone,
antiisoproturon, and antiatrazine, respectively (see Note 3).
3.4. Preparation of the Samples
1. Water samples should show little turbidity; therefore, filter samples through 0.45-µm
membrane filters (Millipore) to remove suspended solids that might cause dispersion of
the emitted light and blockage of the FIA system.
2. As pointed out in Subheading 3.3., step 5, the antibodies need a particular ionic strength
and pH 7.4; therefore, adjust the water samples to the prescribed conditions before their
analysis (7) (see Note 4).
3.5. Preparation of the System
3.5.1. Flow Cell and Rinsing
1. Place the transducer slice within the flow cell and subsequently seal with screws to prevent any leakage but allow the flow of the working and sample solutions through the
active surface.
2. Connect the flow cell to the corresponding tubes of the fluidics system and rinse with
PBS while checking for possible leaks and bubbles in the flow path (see Note 5).
3.5.2. Coupling the Laser
1. Align the laser with the transducer by manually adjusting the incidence angle of the laser
beam on the polished 45° beveled end face of the glass slide so that discrete spots are
formed on both sides of the transducer. This is caused by the total internal reflection of
the laser beam within the transducer.
2. Align selected spots also with three of the six optical fibers, which separately conduce the
light to the photodiodes.
3.6. Perform Binding Measurements
1. Incubate the analyte solution with the antibodies before each measurement. There are two
types of analyte solutions: water samples containing unknown concentrations of analytes
and standard solutions of known analyte concentrations used to calibrate the instrument.
For both standard and unknown solutions, 100 mL of an antibody solution is added to 900
mL of the sample in a 1-mL Eppendorf tube and shaken with a vortex (see Note 6).
2. After incubation for at least 15 min to reach the binding equilibrium, the analyte–antibody solution is delivered into the flow cell by the flow injection system. During this
time, antibodies bind to analyte molecules present in the sample.
3. After rinsing the flow cell with phosphate buffer solution, inject samples into the system
and flow over the transducer surface for 5 min. Only unbound antibodies are able to bind
to the analyte derivative covalently bound on the surface. Antibodies will only interact
with the spots that contain analyte derivatives to which they are directed. During this
process, the laser is switched off to avoid photobleaching of the dyes.
Optical Immunosensors for Pesticides
485
4. After a brief (30-s) rinse with PBS, the laser is turned on, and the evanescent field created
excites locally the bound antibodies in the reflection spots.
5. Collect fluorescence by the optical fibers located under the sensor chip opposite the active spots (8). The signal difference before and after the binding is measured to obtain an
estimation of the number of molecules bound to the transducer layer.
6. After each measurement, rinsing with SDS solution achieves regeneration of the transducer, which allows the performance of a new run (see Note 7). Total analysis time for a
single run is 15 min.
7. A common analytical sequence consists of nine blank measurements (analyte free), nine
calibration standards (minimum of five) from 0 to 100 µg/L, and the samples to analyze.
After incubation and mixing, samples are randomly placed in the autosampler and analyzed automatically (see Note 8). A entire calibration (standards, blanks, and real
samples—all in triplicate) requires about 8 h.
3.7. Performance of the Data Analysis
1. The fluorescence signal decreases with increasing analyte concentration because of the
reduced free antibody concentration that can bind to the surface. Prior to data analysis,
sample fluorescent signals are normalized with the signal corresponding to a blank (maximum fluorescence). Average values (measurements made in triplicate) obtained for the
calibration standards are fitted to a logistic function to plot a calibration curve:
B–A
Y = A + —————————
1 + 10 [(log IC50 - log C)M]
where Y is the fluorescence signal difference (before and after the binding), C is analyte
concentration, A and B are experimentally determined constants, IC50 is the signal corresponding to the inhibition concentration at 50% of absorbance, and M is the slope at the
inflection point.
2. The lower and upper working ranges are defined as the concentrations at which the signal
is quenched by 10 and 90%, respectively. This range depends on the sensitivity (slope) of
the calibration curve.
3. The limit of detection (LOD) is defined as three times the standard deviation of the measurement without analyte (blank sample). The analytical parameters obtained for the target analytes are summarized in Table 1.
4. Normalized fluorescence values obtained with the unknown samples are interpolated in
the calibration curve, and the concentration of the analyte in the sample is thus calculated.
3.8. Validation
Despite the practical advantages of biosensors, they must be verified by comparing
the biosensor results with the results from chemical analysis. This verification process
is known as validation. The RIANA immunosensor has to be checked by analyzing
real samples or spiked real samples by both the multianalyte immunosensor and a
conventional method, usually chromatographic (see Fig. 2).
4. Notes
1. Cross reactivity: The antibodies can react with cross-reactive substances in solution, leading to the determination of a wrong concentration of the target substance. The crossreactivity of the antibody has to be determined before the immunosensor application to a
486
Rodríguez-Mozaz, López de Alda, and Barceló
Table 1
Analytical Calibration Values Obtained for the Target Analytes
Using a Mixture of the Three Antibodies
Analytes
Estrone
Atrazine
Isoproturon
IC50 (µg/L)
0.79
1.84
0.47
LOD (µg/L)
0.08
0.16
0.05
RSD (%)
6.98
1.07
2.89
Working range (µg/L)
0.17–10.7
0.35–1.47
0.11–2.83
IC50, inhibition concentration at 50% absorbance; LOD, limit of detection; RSD, relative standard
deviation; working range, signals from 10 to 90% of the maximal signal at zero dose.
Fig. 2. Correlation between the immunosensor results and those obtained by SPE followed
by LC–MS in the analysis of isoproturon on spiked river water. Regression equation was y =
0.827 × + 0.001, r2 = 0.998. From ref. 12, with permission from Elsevier.
certain compound. In multianalyte approaches, different analyte-specific antibodies are
incubated together with the analytes. Therefore, the effectiveness of the assay is largely
determined by the analyte specificity of the different antibodies. To evaluate the effect
of using a mixture of different antibodies (instead of a single-antibody solution) on the
assay performance, different assays were previously designed and statistical analysis
performed (9,10).
2. Stability: The antibody, as a biological reagent, is the weak component in the analytical
process. The antibody solution decreases its activity after 12 h at room temperature; therefore, it is recommended to keep the solution at 4–8°C. Another aspect is the stability of
the antibody in real samples. Antibodies lose their binding affinity in aggressive matrices
with time. A 10% signal decrease (see Fig. 3) is observed after 17 measurements (one
measurement cycle takes 15 min). Therefore, the time elapsed between the addition of the
antibody to the wastewater and the measurement should never exceed 2 h (7). On the
other hand, the concentration of the background protein OVA can be increased from 0.2
to 2 mg/mL, depending on the matrix complexity, to protect the antibody against the
Optical Immunosensors for Pesticides
487
Fig. 3. Stability of the antibody in wastewater determined with the working immunosensor.
From ref. 7, with permission from Elsevier.
matrix. In addition, the aqueous standard solutions have to be kept at 4–8°C and must be
prepared regularly (see Subheading 3.2.) to avoid standard degradation to cause false
quantification of the samples.
3. LOD: Reduction of the antibody amount per sample results in a decrease of the LOD and
at the same time decreases the signal range of the calibration curve. A compromise has to
be found by which the LOD is in a region of low concentration and the signal range is not
too small; this means a system with high affinities, with the affinity of the antibody higher
for the analyte than for the analyte derivative, and with a concentration of the antibody as
low as possible.
4. Matrix effect: As in other analytical methods, matrix effects derived from their application to the analyses of complex mixtures should be taken into consideration (11). Immunoassays are based on competitive interactions among antibodies, analytes, and analyte
derivatives. These interactions can be affected by the pH or the ionic strength of natural
water matrices. It has also been reported that the presence of other natural substances,
such as dissolved organic carbon, that interact weakly with the antibody can induce an
overestimation of the immunoassay response (12). The influence of ground- and river
water matrices on the immunosensor response has to be evaluated by spiking these matrices with standard solutions and observing the displacement of the calibration curves
obtained (see Fig. 4). Interferences can then be removed by employing simple methods
(diluting and buffering the sample, adjusting pH and conductivity, etc.) or by applying
appropriate cleanup methods (11). As explained, the background protein OVA is added
to a real sample as an immolation protein. Thus, the probability of the antibody adhering
to passive particles in the wastewater is reduced (7).
488
Rodríguez-Mozaz, López de Alda, and Barceló
Fig. 4. Standard calibration curves obtained for estrone in bidistilled water, groundwater,
river water, and wastewater. From ref. 12, with permission from Elsevier.
5. Rinsing: The system should be washed every day before and after finalization of the
measurements by rinsing thoroughly with PBS. Care should be taken to wash the flow
cell repeatedly to avoid precipitation of any contaminants on the flow cell, which will
increase light dispersion. Weekly washing procedures should be carried out using an ethanol rinsing solution to avoid algae formation in the fluidics. This solution must not pass
through the flow cell because it can irreversibly damage the transducer surface.
6. Mixing: Good mixing of each solution is essential. Therefore, vortex mixing is recommended. However, vortex heating can easily denature the proteins. Therefore, it is recommended not to vortex longer than 5 s at a time.
7. Regeneration: In an ideal situation, immunosensors can be reused several times. Only
when the antibodies are completely removed from the surface can a second measurement
take place. Regeneration of the sensing layer takes place by equilibrium displacement of
the immunoreaction or by using agents able to disrupt antibody–analyte association (13).
In this system, acidified SDS solution was used as a regeneration solution. The stability
of the surface depends also on the regeneration of the transducer active surface. The transducers employed with the RIANA device exhibit a long operational time with the
described optimized regeneration step. In the first 50 measurements with a new transducer, the signal decreases strongly, but in the subsequent measurements (up to 300) the
signal stays quite stable. Nevertheless, blank samples are usually measured along the
sequence to normalize the signals obtained.
8. Autosampler: An autosampler AS90/91 from PerkinElmer (Überlingen, Germany) is used
to deliver the samples to the FIA system. Fluid handling and data acquisition are fully
automated and computer controlled. A new autosampler from CTC Analytics, HTC PAS,
has been used coupled to the RIANA. With this new system, there is no need to prepare
and incubate samples and standards before analysis because the new autosampler is able
to select, mix, and inject the samples following a programmed sequence. The new
autosampler also permits better reproducibility with lower relative standard deviations.
Lower LODs are thus also achieved. The RIANA prototype was constructed by
PerkinElmer in the frame of the European Union project RIANA (ENV4-CT95-0066). At
present, only three units are available and are at the laboratories of some of the partners
that participated in the EU project. A new, more advanced prototype has been constructed
by Central Research Laboratories (CRL; Middlesex, UK) within the AWACSS project
Optical Immunosensors for Pesticides
489
(EVK1-CT-2000-00045). This new multisensor system is designed for the monitoring of
water pollution and will consist of a number of remote measurement stations linked by a
communications network. In these stations, highly sensitive biosensors based on fluorescence detection will work unattended, measuring target pollutants levels in water and
sending the results to a control station. The Internet-based control station will have direct
access to each remote measurement unit. Part of the automatization of the new system
involves reduced time and reactives.
Acknowledgments
This work has been supported by the Commission of the European Communities,
AWACSS (EVK1-CT-2000-00045) and Ministerio de Ciencia y Tecnología (project
PPQ 2000-3006-CE). Maria José López de Alda acknowledges a Ramon y Cajal contract from the Spanish Ministry of Science and Technology.
References
1. Parellada, J., Narvaez, A., Lopez, M. A., et al. (1998) Amperometric immunosensors and
enzyme electrodes for environmental applications. Anal. Chim. Acta 362, 47–57.
2. Mallat, E., Barzen, C., Abuknesha, R., Gauglitz, G., and Barcelo, D. (2001) Fast determination of paraquat residues in water by an optical immunosensor and validation using
capillary electrophoresis–ultraviolet detection. Anal. Chim. Acta 427, 165–171.
3. Mallat, E., Barzen, C., Abuknesha, R., Gauglitz, G., and Barcelo, D. (2001) Part per trillion level determination of isoproturon in certified and estuarine water samples with a
direct optical immunosensor. Anal. Chim. Acta 426, 209–216.
4. Mallat, E., Barzen, C., Klotz, A., Brecht, A., Gauglitz, G., and Barcelo, D. (1999) River
analyzer for chlorotriazines with a direct optical immunosensor. Environ. Sci. Technol.
33, 965–971.
5. Klotz, A., Brecht, A., Barzen, C., et al. (1998) Immunofluorescence sensor for water analysis. Sens. Actuators B 51, 181–187.
6. Barzen, C., Brecht, A., and Gauglitz, G. (2002) Optical multiple-analyte immunosensor
for water pollution control. Biosens. Bioelectron. 17, 289–295.
7. Coille, I., Reder, S., Bucher, S., and Gauglitz, G. (2002) Comparison of two fluorescence
immunoassay methods for the detection of endocrine disrupting chemicals in water.
Biomol. Eng. 18, 273–280.
8. Kroger, S., Piletsky, S., and Turner, A. P. F. (2002) Biosensors for marine pollution research, monitoring and control. Mar. Pollut. Bull. 45, 24–34.
9. Vo-Dinh, T., Fetzer, J., and Campiglia, A. D. (1998) Monitoring and characterization of
polyaromatic compounds in the environment. Talanta 47, 943–969.
10. Hennion, M.-C. and Barcelo, D. (1998) Strengths and limitations of immunoassays for
effective and efficient use for pesticide analysis in water samples: a review. Anal. Chim.
Acta 362, 3–34.
11. Marco, M.-P. and Barcelo, D. (1996) Environmental applications of analytical biosensors.
Meas. Sci. Technol. 7, 1547–1562.
12. Rodriguez-Mozaz, S., Reder, S., Lopez de Alda, M., Gauglitz, G., and Barceló, D. (2004)
Simultaneous determination of estrone, isoproturon and atrazine in natural waters by an
optical immunosensor river analyser (RIANA). Biosens. Bioelectron. 19, 633–640.
13. Reder, S., Dieterle, F., Jansen, H., Alcock, S., and Gauglitz, G. (2003) Multi-analyte assay
for triazines using cross-reactive antibodies and neural networks. Biosens. Bioelectron.
19, 447–455.
Index
491
Index
Adipose tissue analysis, see Endosulfan;
Xenoestrogens
Admicelle-based solid-phase extraction–
liquid chromatography–mass
spectrometry,
calibration, 409, 410, 415, 416
identification of quats, 411, 413, 416
materials, 406–408
on-line extraction,
admicelle formation on alumina
surface, 408, 414
elution and injection, 409
overview, 408, 411, 414
percolation of samples, 408, 409
sample preparation, 408, 414
sorbent regeneration, 409, 414
operating conditions, 409, 410
performance, 410, 416
quaternary ammonium herbicides in
drinking water, 405, 406
water sample collection, 408
Air sampling,
calibration solutions, 181, 182, 188
equipment and operation, 180–182,
188
gas chromatography–mass spectrometry
of indoor insecticides,
analyte identification and
quantification, 184, 188
matrix-matched calibration and
sample measurement, 183, 188
measurement parameters, 183, 188
quality assurance, 184, 188, 189
sample preparation,
glass fiber filter, 182
polyurethane foam plugs, 182,
188
indoor insecticides, 179, 180
Atrazine,
food analysis,
magnetic particle immunoassay,
incubation conditions and
detection, 234–237
sample preparation, 234, 236
materials, 232, 233
overview, 231, 232
matrix solid-phase dispersion analysis in
foods and fish,
data analysis, 290, 293
extraction, 287, 288, 291, 292
high-performance liquid
chromatography, 288, 290,
292, 293
identification and quantification, 290,
292, 293
materials, 286, 287, 291
overview, 285–289
sample extraction column
preparation, 287
RIANA analysis,
antibody solution preparation, 483–
487
binding measurements, 484, 485,
488, 489
calibration, 483
data analysis, 485, 486
materials, 483
principles, 481, 482
sample preparation, 484, 487
system preparation, 484, 488
transducer preparation, 483
validation of method, 485, 486
urine analysis with LC–MS,
chromatography, 107–109
electrospray ionization, 108
materials, 106, 109
491
492
overview, 105, 106
sample preparation, 106, 109
Automated trace pesticide analysis in
water,
analyte quantification, 440
analyte retention times and recoveries,
444–447
automation, 440
Combi PAL system, see Headspace
solid phase microextraction–
gas chromatography–mass
spectrometry
fluorescence detection, 440, 443
high-performance liquid chromatography,
439, 442, 443
materials, 436, 437, 441
photodiode array detection, 439, 443
postcolumn derivatization, 440, 443
principles, 435, 436
sample preparation, 437, 441
solid-phase extraction, 437, 441
validation of method, 440, 441, 443, 447
work program for routine sample
analysis, 441, 447, 448
Bentazone, liquid chromatography–liquid
chromatography
determination,
method development, 393, 394
technique, 394, 396, 399
(S)-Bioallethrin, metabolism, 18, 20
Blood analysis, see Plasma analysis;
Serum analysis
Bromoxynyl, liquid chromatography–
liquid chromatography
determination,
method development, 393, 394
technique, 394, 396, 399
Bystander exposure assessment,
data expression,
airborn drift data, 175, 176
analytical data, 175
ground fallout data, 175
mannequin or volunteer data, 176
field site selection, 166, 167
Index
materials, 166
pesticide application,
meteorological conditions, 172
parameters, 171–172
sampling,
fortified and blank samples, 174
media,
airborne pesticides, 169
collection, 172, 173
ground fallout of spray drift, 170
labeling, 173
mannequins or volunteers, 170,
180
positioning in field, 169
storage, 174, 175
overview, 165, 166
spraying equipment,
calibration, 168
factors in selection, 168
nozzle selection, 168
pesticides versus tracers, 167
Capillary electrophoresis–mass spectrometry (CE–MS), fungicide
analysis in fruits and
vegetables,
capillary electrophoresis, 302–304, 308
coupling of instruments, 300–303, 307
extraction, 299, 300, 304, 305, 308
mass spectrometry identification and
quantification, 305, 308
materials, 298, 299
overview, 297, 298
CE–MS, see Capillary electrophoresis–
mass spectrometry
Chlormequat, see Admicelle-based solidphase extraction–liquid
chromatography–mass
spectrometry
Chlorophenols,
high-throughput screening–immunosorbent–ELISA of urine,
alkaline hydrolysis, 136, 141
enzyme-linked immunosorbent
assay, 138–140, 142
Index
high-throughput screening–
immunosorbent–solid-phase
extraction, 136, 137, 141, 142
materials, 135, 136, 140, 141
overview, 133, 134
quality control, 136–138, 142
standards, 136
urine marker, 134
Chlorophenoxycarboxylic acids, see
2,4-Dichlorophenoxyacetic acid;
Molecular imprinted solidphase extraction; 2-Methyl-4chlorophenoxyacetic acid;
Solid-phase microextraction
liquid chromatography–mass
spectrometry
Combi PAL, see Headspace solid phase
microextraction–gas chromatography–mass spectrometry
Cyanazine, matrix solid-phase dispersion
analysis in foods and fish,
data analysis, 290, 293
extraction, 287, 288, 291, 292
high-performance liquid
chromatography, 288, 290,
292, 293
identification and quantification, 290,
292, 293
materials, 286, 287, 291
overview, 285–289
sample extraction column preparation,
287
Cyfluthrin, see Pyrethroids
Cypermethrin, see Pyrethroids
2,4-D, see 2,4-Dichlorophenoxyacetic acid
Deltamethrin, see Pyrethroids
Dermal exposure modeling,
dislodgable foliar residue, 157
generic model, 158
potential dermal exposure, 157
relevance for internal exposure
assessment, 160, 161
sample collection, see Skin sampling
493
tiered approach to risk assessment for
reentry workers, 158, 159
transfer coefficient, 157, 160
DFR, see Dislodgable foliar residue
Dibutyltin, see Organotin compounds
2,4-Dichlorophenoxyacetic acid (2,4-D),
gas chromatography with
electrochemical detection in
urine,
calibration standards, 94, 95
detection limit, 99
materials, 92–94, 99, 100
operational parameters, 96, 97, 100–
101
overview, 92
precision, 98
quality control, 98
recovery, 98
sample preparation, 95, 96, 100
high-performance liquid chromatography
with diode array detection in
urine,
calibration standards, 94, 95
detection limit, 99
materials, 92–94, 99, 100
operational parameters, 96
overview, 92
precision, 98
quality control, 98
recovery, 98
sample preparation, 95, 96, 100
human toxicity, 92
radioimmunoassay,
antibody preparation,
antiserum quality evaluation, 122,
129
immunization of rabbits, 123, 129
protein conjugate preparation for
immunization, 121, 122, 129
calibration curve, 127, 130
cross-reactivity testing, 127, 131
incubation conditions, 125, 126, 130
materials, 120, 121
matrix interferences, 127
494
principles, 119, 120
tritiated tracer synthesis and purification, 123, 124, 129, 130
Dicyclohexyltin, see Organotin compounds
Difenzoquat, see Admicelle-based solidphase extraction–liquid
chromatography–mass
spectrometry
Dioxin, chlorophenol marker, 134
Diphenyltin, see Organotin compounds
Diquat, see Admicelle-based solid-phase
extraction–liquid
chromatography–mass
spectrometry
Dislodgable foliar residue (DFR), dermal
exposure modeling, 157
Dithiocarbamates, see Fungicides
ELISA, see Enzyme-linked immunosorbent
assay
Enantiomers, see α-Hexachlorocyclohexane
Endosulfan,
adipose tissue accumulation, 4
GC–MS/MS analysis in adipose tissue,
extraction, 5, 11
gas chromatography, 6
materials, 5, 11
preparative high-performance liquid
chromatography, 6, 11, 12
sample analysis, 7, 8, 12, 13
stock solution preparation, 5, 11
tandem mass spectrometry
parameters, 7
uncertainty estimation, 8–10, 13
validation of method, 6, 7, 12
isomers, 4
Enzyme-linked immunosorbent assay
(ELISA),
chlorophenol high-throughput
screening–immunosorbent–
ELISA of urine samples,
alkaline hydrolysis, 136, 141
enzyme-linked immunosorbent assay,
138–140, 142
Index
high-throughput screening–
immunosorbent–solid-phase
extraction, 136, 137, 141, 142
materials, 135, 136, 140, 141
overview, 133, 134
quality control, 136–138, 142
standards, 136
food analysis of atrazine and 3,5,6trichloro-2-pyridinol,
magnetic particle immunoassay for
atrazine,
incubation conditions and
detection, 234–237
sample preparation, 234, 236
materials, 232, 233
microwell plate immunoassay for
3,5,6-trichloro-2-pyridinol,
incubation conditions and
detection, 235, 236
sample preparation, 235
overview, 231, 232
Estrogens, see Xenoestrogens
Ethylenebisdithiocarbamates,
ethylenethiourea detection in urine,
calibration curve preparation, 84,
88
creatinine assay, 84
deuterated standard preparation, 81,
87
extraction and derivatization, 82, 87,
88
field study, 87
gas chromatography–mass
spectrometry, 82, 84
materials, 80, 81
overview, 79, 80
sampling,
agricultural workers, 86, 88
controls, 86, 88
handling and storage, 86, 87, 89
metabolism, 79
Fish, see Matrix solid-phase dispersion
Index
Food analysis, see Atrazine; Fungicides; Gas
chromatography–tandem mass
spectrometry; αHexachlorocyclohexane; Matrix
solid-phase dispersion;
Microwave-assisted extraction;
Organophosphorous pesticides;
QuEChERS; 3,5,6-Trichloro-2pyridinol
Fungicides,
capillary electrophoresis–mass
spectrometry analysis in fruits
and vegetables,
capillary electrophoresis, 303, 304,
307
coupling of instruments, 300–303, 307
extraction, 299, 300, 305, 307
mass spectrometry identification and
quantification, 305, 308
materials, 298, 299
overview, 297, 298
dithiocarbamates, 319, 320
microwave-assisted extraction, see
Microwave-assisted extraction
Gas chromatography, see 2,4Dichlorophenoxyacetic acid; 2Methyl-4-chlorophenoxy-acetic
acid; Organophosphorous
pesticides
Gas chromatography–mass spectrometry
(GC–MS), see Air sampling;
Ethylenebisdithiocarbamates;
Headspace solid phase microextraction–gas chromatography–
mass spectrometry; α-Hexachlorocyclohexane; Isotope
dilution gas chromatography–
high-resolution mass
spectrometry; Organochlorine
pesticides; Pentachlorophenol;
Pyrethrins; Pyrethroids;
QuEChERS; Water analysis
495
Gas chromatography–tandem mass
spectrometry (GC–MS/MS),
current-use pesticide monitoring in
urine,
comprehensive approach, 61, 62
data processing, 73
dialkylphosphate method, 72, 77
materials, 62, 63
multianalyte method, 72, 77
pesticide types and markers, 64–66
phenols method, 72, 77
quality control, 63, 74, 76
quality control, 73
sample preparation, 70, 71, 77
standards, 63–70, 74, 76
validation of method, 73–76
endosulfan in adipose tissue,
extraction, 5, 11
gas chromatography, 6
materials, 5, 11
preparative high-performance liquid
chromatography, 6, 11, 12
sample analysis, 7, 8, 12, 13
stock solution preparation, 5, 11
tandem mass spectrometry
parameters, 7
uncertainty estimation, 8–10, 13
validation of method, 6, 7, 12
malathion,
extraction,
personal protective equipment,
195, 202
polyurethane foam plugs, 195
urine samples, 194, 195, 202
field trial design, 199–201, 204
instrument parameters, 195, 196, 202
materials, 193
overview, 192, 193
sampling,
air samples, 193, 200
field quality control, 194, 201
media, 193, 200
urine, 193, 201
stock solutions, 194
496
validation,
biomonitoring method, 199, 204
dermal exposure method, 196,
197, 202
inhalation exposure method, 197–
199, 202–204
vegetable analysis using low-pressure
gas chromatography–tandem
mass spectrometry,
extraction of pesticides, 275, 276
identification and quantification, 276,
279–282
instrumental determination, 275–279
materials, 274–276
overview, 273, 274
GC–MS, see Gas chromatography–mass
spectrometry
GC–MS/MS, see Gas chromatography–
tandem mass spectrometry
Glyphosate, liquid chromatography–liquid
chromatography determination,
method development, 395, 396, 399
technique, 396, 399–401
Headspace solid phase microextraction–gas
chromatography–mass
spectrometry,
automated Combi PAL system, 345, 346,
355
gas chromatography–mass spectrometry,
347, 351, 359
headspace solid phase microextraction,
347, 355, 356, 358, 359
identification and quantification, 352,
354
materials, 345, 346, 355
pesticide analytes, 348–351
principles of water analysis, 343–345
recovery, 351, 352, 359–361
sample preparation, 346, 347, 355
solid-phase extraction, 355, 359
water samples, 346
α-Hexachlorocyclohexane,
applications, 331
Index
enantioselective determination in foods,
evaporation, 333, 337, 338
extraction, 333, 337
gas chromatography–mass
spectrometry, 334–336, 338, 339
lipid determination, 333, 334
lipid removal, 334
materials, 332, 333, 336, 337
overview, 332
quality control, 336, 339
solid-phase extraction cleanup and
fractionation, 334, 338
standard solution preparation, 333,
337
structure, 332
High-performance liquid chromatography
(HPLC), see Automated trace
pesticide analysis in water;
2,4-Dichlorophenoxyacetic
acid; Liquid chromatography–
liquid chromatography;
Liquid chromatography–mass
spectrometry; Matrix solidphase dispersion; 2-Methyl-4chlorophenoxyacetic acid
High-performance liquid chromatography–
tandem mass spectrometry
(HPLC–MS/MS),
current-use pesticide monitoring in
urine,
comprehensive approach, 61, 62
data processing, 73
dialkylphosphate method, 72, 77
materials, 62, 63
multianalyte method, 72, 77
pesticide types and markers, 64–66
phenols method, 72, 77
quality control, 63, 73, 74, 76
sample preparation, 70, 71, 77
standards, 63–70, 74, 76, 77
validation of method, 73–76
QuEChERS, see QuEChERS
High-throughput screening, see Enzymelinked immunosorbent assay
Index
HPLC, see High-performance liquid
chromatography
Immunoassay, see Enzyme-linked
immunosorbent assay;
Radioimmunoassay
Inhalation exposure,
estimation, 159, 160
malathion, see Malathion
sampling, 150, 151
Internal quality control (IQC),
basic activities in pesticide analysis,
220–222
definition, 220
identification criteria, 227
importance, 220
mass spectrometry pesticide
confirmation criteria, 228,
229
full scan, 228
selected ion monitoring, 228
measures,
blanks, 222
blind samples, 226
calibrating standards, 224, 226
certified reference materials and
quality control samples, 222, 224
replicated samples, 226
spiked samples, 226
IQC, see Internal quality control
Isoproturon,
liquid chromatography–liquid
chromatography determination,
method development, 391, 392
technique, 392, 393, 397, 399
RIANA analysis,
antibody solution preparation, 483–
487
binding measurements, 484, 485,
488, 489
calibration, 483
data analysis, 485, 486
materials, 483
principles, 481, 482
497
sample preparation, 484, 487
system preparation, 484, 488
transducer preparation, 483
validation of method, 485, 486
Isotope dilution gas chromatography–
high-resolution mass
spectrometry,
blood analysis, 36, 37
multianalyte analysis of current-use
pesticides,
blanks, 40, 41
data analysis, 41
instrumental analysis, 40–45
materials, 37
pesticide types, 38
quality control, 39
sample preparation, 40, 45
standards,
calibration standards, 38
internal standards, 38, 41
native standards, 37
validation of method, 41, 45
LC/LC, see Liquid chromatography–liquid
chromatography
LC–MS, see Liquid chromatography–mass
spectrometry
Liquid chromatography–liquid
chromatography (LC/LC),
bentazone and bromoxynyl
determination,
method development, 393, 394
technique, 394, 396, 399
development of analytical method, 384,
385, 387, 389, 390, 397
glyphosate and AMPA metabolite
determination,
method development, 395, 396, 399
technique, 396, 399–401
interferences, 384
isoproturon determination,
method development, 391, 392
technique, 392, 393, 397, 399
materials, 390, 391
498
Liquid chromatography–mass spectrometry
(LC–MS), see Admicelle-based
solid-phase extraction–liquid
chromatography–mass
spectrometry; Atrazine;
Pentachlorophenol; Simazine;
Solid-phase micro-extraction
liquid chromat-ography–mass
spectrometry; Water analysis
Low-pressure gas chromatography, see Gas
chromatography–tandem mass
spectrometry
MAE, see Microwave-assisted extraction
Malathion,
gas chromatography–tandem mass
spectrometry for dermal and
inhalation exposure
assessment,
extraction,
personal protective equipment,
195, 202
polyurethane foam plugs, 195
urine samples, 194, 195, 202
field trial design, 199–200, 204
instrument parameters, 195, 196, 202
materials, 193
overview, 192, 193
sampling,
air samples, 194, 201
field quality control, 194, 201
media, 193, 200
urine, 193, 200
stock solutions, 194
validation,
biomonitoring method, 199, 204
dermal exposure method, 196,
197, 202
inhalation exposure method, 197–
199, 202–204
metabolism, 192
Mass spectrometry (MS), see also Capillary
electrophoresis–mass
spectrometry; Gas
Index
chromatography–mass
spectrometry; Gas
chromatography–tandem mass
spectrom-etry; Highperformance liquid
chromatography–tandem mass
spectrometry; Liquid
chromatography–mass
spectrometry,
pesticide confirmation criteria,
full scan, 227
selected ion monitoring, 228
tandem mass spectrometry, 228
Matrix solid-phase dispersion (MSPD),
advantages, 285, 286
triazine analysis in foods and fish,
data analysis, 290, 293
extraction, 287, 288, 291, 292
high-performance liquid
chromatography, 288, 290,
292, 293
identification and quantification, 290,
292, 293
materials, 286, 287, 291
overview, 285–289
sample extraction column
preparation, 287
MCPA, see 2-Methyl-4chlorophenoxyacetic acid
Mepiquat, see Admicelle-based solid-phase
extraction–liquid
chromatography–mass
spectrometry
2-Methyl-4-chlorophenoxyacetic acid
(MCPA),
gas chromatography with electrochemical detection in urine,
calibration standards, 94, 95
detection limit, 99
materials, 92–94, 99, 100
operational parameters, 96, 97, 100–
101
overview, 92
precision, 98
Index
quality control, 98
recovery, 98
sample preparation, 95, 96, 100
high-performance liquid chromatography
with diode array detection in
urine,
calibration standards, 94, 95
detection limit, 99
materials, 92–94, 99, 100
operational parameters, 96
overview, 92
precision, 98
quality control, 98
recovery, 98
sample preparation, 95, 96, 100
human toxicity, 92
Metribuzin, matrix solid-phase dispersion
analysis in foods and fish,
data analysis, 290, 293
extraction, 287, 288, 291, 292
high-performance liquid chromatography, 288, 290, 292, 293
identification and quantification, 290,
292, 293
materials, 286, 287, 291
overview, 285–289
sample extraction column preparation,
287
Microwave-assisted extraction (MAE),
dithiocarbamate analysis in
foods,
calibration curves, 323–325, 328
calibration standards, 322, 327
gas chromatography, 322, 328
materials, 320, 321, 325, 325
overview, 319, 320
safety precautions, 321
sample preparation and extraction, 321,
322, 325
validation of method, 324, 325, 328
Milk analysis, see Organochlorine
pesticides
MISPE, see Molecular imprinted solidphase extraction
499
Molecular imprinted solid-phase extraction
(MISPE), chlorinated
phenoxyacids from water
samples,
column preparation, 424, 425, 431
extracted analyte analysis,
capillary electrophoresis, 428, 429,
432
high-performance liquid
chromatography, 429, 430,
432
extraction, 425–427, 431, 432
materials, 422, 423
overview, 421, 422
2,4,5-trichlorophenoxyacetic acid
imprinting, 423, 424, 430,
431
Monobutyltin, see Organotin compounds
Monophenyltin, see Organotin compounds
MS, see Mass spectrometry
MSPD, see Matrix solid-phase dispersion
OCPs, see Organochlorine pesticides
OP pesticides, see Organophosphorous
pesticides
Optical immunosensor, see RIANA
Organochlorine pesticides (OCPs), see also
Chlorophenoxycarboxylic
acids,
air sampling, see Air sampling
persistence, 49
solid-phase disk extraction with gas
chromatography–mass
spectrometry analysis in body
fluids,
elution and cleanup, 53–55
gas chromatography–mass
spectrometry analysis, 55, 58
materials, 50, 51
overview, 50
quality control, 56, 57
sample preparation and loading, 51–
53, 57, 58
validation of method, 55, 56
500
Organophosphorous (OP) pesticides,
air sampling, see Air sampling
supercritical fluid extraction for cereal
and dried food analysis,
calibration solution preparation, 313,
316
cleanup of extracts, 314–316
extraction, 313, 314, 316
gas chromatography,
flame photometric detection, 315
mass spectrometry detection, 315–
317
identification and calibration, 315, 317
materials, 312, 313, 315, 316
overview, 311, 312
sample preparation, 313, 314, 316
vegetable oil analysis using gas
chromatography with flame
photometric detection,
calculations, 267, 270
materials, 264, 265
overview, 264
performance, 269, 270
pesticide identification, 267
recovery values, 267–269
sample preparation, 265, 266, 269, 270
Organotin compounds,
applications, 454
gas chromatography–high-resolution
mass spectrometry of water
samples,
calibration and limits of detection, 462
materials, 454, 455
operating conditions, 456
overview, 453, 454
quality control, 460, 464
quantification, 462, 465
recovery of analytes, 463, 465
sample preparation,
batch composition, 455, 464
derivatization and extraction, 456,
464
glassware cleaning, 455, 463, 464
standards, 456, 464
Index
selected ion monitoring, 458–460
validation of method, 455, 456, 464
types, 453
Paraquat, see Admicelle-based solid-phase
extraction–liquid
chromatography–mass
spectrometry
PCP, see Pentachlorophenol
Pentachlorophenol (PCP),
biological sample analysis,
gas chromatography–mass
spectrometry, 113, 115, 117
liquid chromatography–mass
spectrometry, 114, 117
liquid–liquid extraction, 113, 116
materials, 112
performance, 114, 117
solid-phase extraction, 113
solid-phase microextraction, 113,
116, 117
standards, 112, 113, 116
human toxicity, 111, 112
Permethrin, see Pyrethroids
Plasma analysis, see Isotope dilution gas
chromatography–highresolution mass spectrometry;
Pyrethrins; Pyrethroids
Postcolumn derivatization, see Automated
trace pesticide analysis in
water
Pyrethrins,
human toxicity, 18
metabolism, 18
urine metabolite analysis using GCMS,
analysis, 28, 32, 33
gas chromatography parameters, 27, 28
mass spectrometry parameters, 27, 28
materials, 22, 23
overview, 21, 31, 32
sample preparation, 27
sample storage stability, 31
validation of method, 28, 31
Index
Pyrethroids,
air sampling, see Air sampling
human toxicity, 18
metabolism, 18, 19
plasma analysis using GC-MS,
analysis, 24
gas chromatography parameters, 24, 32
mass spectrometry parameters, 24,
25, 32
materials, 21, 22
overview, 18, 20, 31
sample preparation, 23, 24, 32
sample storage stability, 25
validation of method, 25
urine metabolite analysis using GC-MS,
analysis, 28, 32, 33
gas chromatography parameters, 27, 28
mass spectrometry parameters, 28
materials, 22, 23
overview, 20–21, 31, 32
sample preparation, 27
sample storage stability, 31
validation of method, 28, 31
Quality assurance, overview, 219, 220
Quality control, see Internal quality control
Quats, see Admicelle-based solid-phase
extraction–liquid
chromatography–mass
spectrometry
QuEChERS,
advantages, 239, 240
calibration, 241, 243
calibration standard preparation, 251,
252
data analysis, 256
extract handling for analysis, 250, 251
food samples,
communition, 246, 249, 258
extraction and cleanup, 249, 250, 258
gas chromatography-amenable pesticide
residues, 243
gas chromatography–mass spectrometry,
252–254
501
liquid chromatography-amenable
pesticide residues, 244, 245
liquid chromatography–tandem mass
spectrometry, 254, 255
materials, 245–248, 256–258
pesticide analytes, 241, 242
principles, 240, 241
Quick, ease, cheap, effective, rugged and
safe method, see QuEChERS
Radioimmunoassay, see 2,4Dichlorophenoxyacetic acid
RIANA,
antibody solution preparation, 483–487
binding measurements, 484, 485, 488,
489
calibration, 483
data analysis, 485, 486
materials, 483
principles, 481, 482
sample preparation, 484, 487
system preparation, 484, 488
transducer preparation, 483
validation of method, 485, 486
River analyzer, see RIANA
Selected ion monitoring, see Mass
spectrometry
Serum analysis, see Isotope dilution gas
chromatography–high-resolution
mass spectrometry;
Organochlorine pesticides;
Xenoestrogens
SFE, see Supercritical fluid extraction
Simazine,
matrix solid-phase dispersion analysis in
foods and fish,
data analysis, 290, 293
extraction, 287, 288, 291, 292
high-performance liquid
chromatography, 288, 290,
292, 293
identification and quantification, 290,
292, 293
502
materials, 286, 287, 291
overview, 285–289
sample extraction column
preparation, 287
urine analysis with LC-MS,
chromatography, 107–109
electrospray ionization, 108
materials, 106, 109
overview, 105, 106
sample preparation, 106, 109
Skin sampling,
comparison of methods, 156
direct methods,
in situ detection, 153, 154
removal techniques,
tape stripping, 153
washing, 152
wiping, 152, 153
surrogate skin techniques, 151, 152
exposure modeling, see Dermal exposure
modeling
indirect methods,
biological monitoring, 155
surface sampling, 154, 155
Solid-phase disk extraction, see
Organochlorine pesticides
Solid-phase microextraction (SPME), see
Headspace solid phase
microextraction–gas chromatography–mass spectrometry;
Pentachlorophenol; Solid-phase
microextraction liquid
chromatography–mass
spectrometry,
Solid-phase microextraction liquid chromatography–mass spectrometry,
automated in-tube analysis,
liquid chromatography–mass
spectrometry analysis,
chlorinated phenoxy acid
herbicides, 369, 371, 376–378
triazenes, 372, 377, 379
solid-phase microextraction, 369,
373–376
Index
materials, 366, 367, 372
pesticide analytes, 368
principles of water analysis, 365, 366
recovery, 372, 380
water sample preparation, 367, 369,
373
SPME, see Solid-phase microextraction
Supercritical fluid extraction (SFE),
organophosphorous pesticide
extraction for cereal and dried
food analysis,
calibration solution preparation, 313, 316
cleanup of extracts, 314–316
extraction, 313, 314, 316
gas chromatography,
flame photometric detection, 315
mass spectrometry detection, 315–317
identification and calibration, 315, 317
materials, 312, 313, 315, 316
overview, 311, 312
sample preparation, 313, 314, 316
3,5,6-TCP, see 3,5,6-Trichloro-2-pyridino
Tetrabutyltin, see Organotin compounds
Transfer coefficient, dermal exposure
modeling, 157, 160
Triazines, see Atrazine; Cyanazine;
Metribuzin; Simazine; Solidphase microextraction liquid
chromatography–mass
spectrometry; RIANA; Water
analysis
Tributyltin, see Organotin compounds
2,4,5-Trichlorophenoxyacetic acid, see
Molecular imprinted solidphase extraction
3,5,6-Trichloro-2-pyridinol (3,5,6-TCP),
food analysis, 231, 232
microwell plate immunoassay,
incubation conditions and detection,
235, 236
sample preparation, 235
Tricyclohexyltin, see Organotin compounds
Triphenyltin, see Organotin compounds
Index
Uncertainty,
estimation, 5, 8–10, 13
standard versus expanded, 4
Urine analysis, see Atrazine;
Chlorophenols; 2,4Dichlorophenoxyacetic acid;
Ethylenebisdithiocarbamates;
Gas chromatography–tandem
mass spectrometry; Highperformance liquid
chromatography–tandem mass
spectrometry; Malathion; 2Methyl-4-chlorophenoxyacetic
acid; Pyrethroids; Simazine
Vegetable oil, see Organophosphorous
pesticides
Vegetables, see Fungicides; Gas
chromatography–tandem mass
spectrometry
Water analysis, see also Admicelle-based
solid-phase extraction–liquid
chromatography–mass
spectrometry; Automated trace
pesticide analysis in water;
Headspace solid phase
microextrac-tion–gas
chromatography–mass
spectrometry; Molecular
imprinted solid-phase extraction;
Organotin compounds; Solidphase microextraction liquid
chromatography–mass
spectrometry
river analyzer, see RIANA
triazines and degradation products,
detection limits, 476, 477
gas chromatography/large-volume
injection–mass spectrometry,
469, 471, 477
liquid chromatography–atmospheric
pressure chemical ionization
source mass spectrometry,
471–473, 476–478
503
liquid chromatography–atmospheric
pressure chemical ionization
source tandem mass
spectrometry, 473, 475, 477,
478
overview, 467, 468
sample collection and preservation,
468, 477
solid-phase extraction, 468, 469,
470, 477
Xenoestrogens,
adverse health effects, 207, 208
exposure assessment,
bioassay with E-screen assay,
cell proliferation and dose–
response, 213, 214
charcoal–dextran treatment of
serum, 212
MCF-7 cells, 212
TEXB estimation, 213
extraction,
adipose tissue, 210, 214
serum, 210, 214
gas chromatography of
organochlorine compounds,
211, 212, 214
high-performance liquid
chromatography, 210, 210
lipid determination, 210
materials, 208–210
sample collection, 210, 214
Sep-Pak cleanup, 211, 214
RIANA analysis,
antibody solution preparation, 483–487
binding measurements, 484, 485,
488, 489
calibration, 483
data analysis, 485, 486
principles, 481, 482
sample preparation, 484, 487
system preparation, 484, 488
transducer preparation, 483
validation of method, 485, 486
M E T H O D S
I N
B I O T E C H N O L O G YTM 䊐
19
Series Editor: John M. Walker
Pesticide Protocols
Edited by
José L. Martínez Vidal and Antonia Garrido Frenich
Department of Analytical Chemistry, Faculty of Sciences
University of Almería, Almería, Spain
Recent advances in the analysis of pesticide residues in both environmental and food
commodities hold out the possibility of analyzing many pesticides in one analytical run.
In Pesticide Protocols, expert researchers—who have each perfected the techniques they
write about—describe in step-by-step detail robust methods for the detection of pesticide
compounds or their metabolites, techniques that are highly useful in food, environmental,
and biological monitoring, and in studies of exposure via food, water, air, and the skin or
lungs. The methods range from gas and liquid chromatography coupled to mass spectrometry detection and other classic detectors, to capillary electrophoresis and immunochemical
or radioimmunoassay techniques. The authors apply these broad-ranging techniques to the
analysis of several families of pesticides, to pesticide residues in vegetables, to pesticides
in water and air, and to pesticide exposure. The authors have focused on extraction and
cleanup procedures in order to develop and optimize more fully automated and miniaturized
methods, including solid-phase extraction, solid-phase microextraction, microwave-assisted extraction, and on-line tandem liquid chromatography trace enrichment, among
others. The protocols follow the successful Methods in Biotechnology™ series format, each
offering step-by-step laboratory instructions, an introduction outlining the principles behind the technique, lists of the necessary equipment and reagents, and tips on troubleshooting and avoiding known pitfalls.
Comprehensive and versatile, Pesticide Protocols offers analysts powerful and highly practical tools for analyzing the presence of pesticides in complex matrices.
Features
䊏 Readily reproducible methods for
analyzing pesticides in air, water,
food, and the body
䊏 Applications to several families of
pesticides
䊏 Liquid and gas chromatography
coupled to mass spectrometry
detection
Methods in Biotechnology™ • 19
PESTICIDE PROTOCOLS
ISBN: 1-58829-410-2 E-ISBN: 1-59259-929-X
humanapress.com
View publication stats
䊏 Extensive bibliography for each
method
䊏 Step-by-step instructions to ensure
successful results
䊏 Tricks of the trade and notes on
troubleshooting and avoiding
known pitfalls